1 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN A connector Digital display DA 8 Technical data: Input signal:...0 ma, -wire Polarity: reverse polarity protection Voltage drop: approx. 3V Accuracy: 0,% FS ± 1 digit Display: 10mm high LCD-display Display range: to Decimal point: any position Scale: freely adjustable via 3 buttons (access. after cover has been removed) Sampling rate: approx. 3 samples/sec. Filter: setable in 3 positions (damping) Limit display: above/below permissible range/ not permissible Electrical. connection: special plug EN A IP65 Housing: 8,5x8,5x35,5 (LxWxD) ABS, window polycarbonate, IP 65 Ambient temperature: C Temperature coeff.: 0,01%/K
2 Dimensions Plug-in local display DA DA8 8.0 Nöding Meßtechnik GmbH 13 Hamburg Display can be rotated 360 and the LCDs in 90 steps. Fits all transmitters with 0 ma output and EN A connector. Electrical connections EN A connector ma -wire PIN1 Signal + PIN Signal PE Modifications reserved without notice, 0.10 Nöding Meßtechnik GmbH Oldenfelder Bogen 9 D-13 Hamburg Germany Tel. 00 / Fax 00 / Internet: info@noeding-messtechnik.de
3 5 mm housing for DIN rail Pt 100 input, 3-wire Supply voltage 18 30V DC Output 0()...0 ma / V switchable Temperature transmitter EMW 63. Technical data: Input signal: Pt 100, 3-wire Output signal: 0() 0 ma, max V, max. 5 ma, switchable Short-circuit current < 30 ma Accuracy ± 0,3% 5 C Residual ripple: < 50 mvpp Power supply: 18 30V DC, max. 50 ma Ambient temperature: C Temperature coeff.: ± 0,0% FS/K Housing: Polyamide 6.6
4 Ordering code ordering code range EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C EMW 63./0/ C Dimensions Ausgang 0-0 ma + V DC U/I OUT I EMW 63. Nöding Meßtechnik GmbH -0mA 0-10V Pt % C Electrical connections Pt V DC U/I OUT + 3 Modifications reserved without notice, 0.10 Nöding Meßtechnik GmbH Oldenfelder Bogen 9 D-13 Hamburg Germany Tel. 00 / Fax 00 / Internet: info@noeding-messtechnik.de
5 Adjustable temperature controller for Pt 100 Low-Cost version,5 mm housing for DIN rail Power supply V DC Circuit monitoring for break and short-circuit Temperature switch ERW 7. Technical data: Input: Pt 100, 3-wire Accuracy: ± % 5 C Switch hysterisis: approx. 1% of span Error controll: Break or short-circuit of the measuring circuit affects like setpoint exceed. Output: Relay with potential-free change-over contact. Relay is activated, when actual value < set point Switching power: 50V AC max. 600 VA 15V DC max. 10 W max. switching current 3A Power supply: 18 30V DC, max. 0 ma, max. ripple 10% within the admissible range Ambient temperature: 0 60 C, effect < 0,0%/K Enclosure: Polyamide, IP 0
6 Ordering code Ordering code range ERW 7./0/ C ERW 7./0/ C ERW 7./0/ C ERW 7./0/ C ERW 7./0/ C ERW 7./0/ C Dimensions L+ S ERW L Electrical connections 1 3 L+ L Modifications reserved without notice, 0.10 Nöding Meßtechnik GmbH Oldenfelder Bogen 9 D-13 Hamburg Germany Tel. 00 / Fax 00 / Internet: info@noeding-messtechnik.de
7 Digital contact thermometer 3-digit 1mm LED display 63mm stainless steel bayonet lock case Min./max. memory Ranges from 0 50 C to C Easy on-site configuration Analog output: 0()...0 ma, V Contact output: DC PNP, max. 00 ma Digital contact thermometer TM 63 Technical Data: Range: Analog output: Contact output: Accuracy: Response time: Power supply: 0 50 C bis C 0()...0 ma, 0 10 V DC PNP, max. 00 ma ± 0.3% 5 C + 0,3 C C x t (Pt1000 Kl. B) 00 ms V DC, 0 ma Ausgang 16 30V DC, 10 V Ausgang Ambient temperature: C Process temperature: C Temperature coefficient: ± 0.0% FS/K Long term stability: ± 0.% FS p. a. Bayonet lock case: (30) IP 67 Process connection: G 1/, 1.0 (316L) Electrical connection: M8x1 -pin connector
8 Ranges Range Code C C C C 0 10 C C C C C A C B C C C D C E C F C G C H C J C K C L C M C N C O C P C Q Other ranges on request Ordering code Type A Axial, connection back W Bottom connection Analog output V 3-wire 0 0 ma 3-wire 3 0 ma 3-wire (signal range ma) Contact output 1 1 Contact Range Measurement range see table 9 others on request Process connection and material 3 G1/ male swivel nut 1.0 G G1/ union nut 1.0 Sensor Length mm mm others mm on request 5 50 mm Accuracy class 0 Pt 1000 Cl. B (Standard) 1 Pt 1000 Cl. A Optiones 0 without TM63 Dimension (mm) Type A C Ø 6.0 male nut G1/ type 3 Enter 1.0 TM 63 L Ø 63.0 union nut G1/ type G 1.0 male nut G1/ type 3 L Type W Ø 6.0 Electrical connections Accessories (optional) 1 3 Connector M8x1 -polig Elbow-Connector M8x1, -polig with m PVC Cable; Typ: AKW-8--P 18.0 Thermowell SH-1-05 L = 50 mm SH-1-10 L = 100 mm SH-1-16 L = 160 mm SH-1-5 L = 50 mm 1 brown L+ 3 white black blue L- SP1 7.0 M8x1 Ø 9x1 EL = L+1.0 G1/" G1/" Modifications reserved without notice 0.10 Nöding Meßtechnik GmbH Oldenfelder Bogen 9 D-13 Hamburg Germany Tel. 00 / Fax 00 / Internet: info@noeding-messtechnik.de
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationCONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationW150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
More informationSafety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationTest equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationwww.suco.de Electronic Pressure Monitoring New Products
Electronic Pressure Monitoring New Products RoHS compliant Electronic Pressure Switches SoS-Technology with one or two switching functions Electronic Pressure Switches CE marking SUCO Electronic pressure
More informationPolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
More informationThermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
More informationUM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationThru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationFast, reliable, ultra-precise. My-Com precision switches.
Fast, reliable, ultra-precise.. Unrivaled 1 μm repeat accuracy Setting reference points, monitoring tolerances, controlling, adjusting. Fast, reliable, ultra-precise. Uncompromising accuracy tried and
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More informationLED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationElectrical connection
(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold
More informationProximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30 Euronorm thermoplastic polyester housing, cylindrical Diameter: M 12, M 18, M 30. Sensing distance: 2 to 15 mm
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationSeries 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More informationUSB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationCONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
More informationPTU Series Transducer Digital Display Indicator User s Manual
PTU Series Transducer Digital Display Indicator User s Manual The Swagelok PTU series digital display indicator is available to mount directly to the Swagelok PTU series transducer to provide local indication
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationDatalogger DL/N 70 Version: 28.03.2012
Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationELECTROMAGNETIC FLOWMETER COMPACT
R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy:
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationDALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationTilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationIncubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationpsens Pressure Measurement
Mobile Machine Control Solutions psens Pressure Measurement Reliable Compact Versatile Unique Measurement Accuracy psens. Pressure Sensors from Hirschmann MCS Hirschmann pressure transducers are an ideal
More informationW 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability
Photoelectric proximity switches, FGS Photoelectric reflex switches Through-beam photoelectric switches W -: Incorporated application Know-how, expanded functionality, high level of equipment availability
More informationLiquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
More informationE2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL
High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationcrm+130/iu/tc/e Extract from our online catalogue: Current to: 2016-04-21
Extract from our online catalogue: crm+130/iu/tc/e Current to: 2016-04-21 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de
More informationSupplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107
Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationW 260: Standard photoelectric switch series for a broad range of applications
W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationTemp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
More informationL-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More information