Caledonian. FIRETOX Flame Retardant RS485 Databus Cables
|
|
|
- Sabrina Hodge
- 9 years ago
- Views:
Transcription
1 FIRETOX Flame Retardant RS485 Databus Cables
2 Flame Retardatant RS485 Databus Cables Company Prile. established in 1978.fers one the most complete lines fiber and copper cabling system solutions with over hundreds different cabling system products.. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc. Cables fers a comprehensive stock cables and cabling products through its nationwide network resellers and distributors. Cables has continually expanded its global presence in Europe and Asia. & Addison. produces a wide range cables for communication. power and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually keep expanding our manufacturing capabilities in more low cost region such as Romania. Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible. scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing. logistic services. and vertically integrated with our ecommerce technologies. to optimize customer operations by lowering costs and reducing time to market. & Addison has been respected for its high standards quality. excellent service level. competitive pricing and a unique and innovative spirit. With our latest technologies. we are both inspired and well-positioned to meet the changing needs our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning. we are ready for the future and the promise new marketing opportunities. Our tradition growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range products and technologies and to develop customized. country and industry-specific solutions. & Addison has established an extensive network design. manufacturing. and logistics facilities in the world s major markets to serve the growing outsourcing needs both multinational and regional customers. 2
3 Table Contents LSZH Flame Retardant RS485 Screened Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened Multi RS 485 Databus Cables...5 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened Multi RS 485 Databus Cables...8 Foam PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened Multi RS 485 Databus Cables...11 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened Multi RS 485 Databus Cables...14 Foam PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened Multi RS 485 Databus Cables...17 Foam Skin PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened Multi RS 485 Databus Cables...20 Foam PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables...23 Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables...26 LSZH Flame Retardant RS485 Screened & SWB Armoured Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...29 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...32 Foam PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened. Steel Wire Braid Armoured Multi RS 485 Databus Cables...35 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...38 ADDISON 3
4 ADDISON Foam PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...41 Foam Skin PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...44 Foam PE Insulated, LSZH ed, Copper Wire Braid Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...47 Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables...50 LSZH Flame Retardant RS485 Screened & GSWA Armoured Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...53 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...56 Foam PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...59 Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape & Copper Wire Braid Double Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...62 Foam PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...65 Foam Skin PE Insulated, LSZH ed, Individual Aluminum/polyester TapeScreen & Copper Wire Braid screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables.68 Foam PE Insulated, LSZH ed, Copper Wire Braid Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...71 Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables...74 Technical Information
5 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened Multi RS 485 Databus Cables RE-02Y(St)H LSZH Outer Foam PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 5
6 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H /
7 Flame Retardant RS485 Databus Cables No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 7
8 ADDISON Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened Multi RS 485 Databus Cables RE-02YS(St)H LSZH Outer Foam Skin PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
9 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / ADDISON 9
10 ADDISON No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
11 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminium/polyester Tape & Copper Wire Braid Double Screened Multi RS 485 Databus Cables RE-02Y(St)CH Copper Wire Braid Foam PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 11
12 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminium/polyester tape+copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH /
13 Flame Retardant RS485 Databus Cables No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)CH / RE-02Y(St)CH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 13
14 ADDISON Foam Skin PE Insulated, LSZH ed, Aluminium/polyester Tape & Copper Wire Braid Double Screened Multi RS 485 Databus Cables RE-02YS(St)CH Copper Wire Braid Foam Skin PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
15 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminium/polyester tape+copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / ADDISON 15
16 ADDISON No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)CH / RE-02SY(St)CH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
17 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened Multi RS 485 Databus Cables RE-02Y(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 17
18 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf /
19 Flame Retardant RS485 Databus Cables No. Strands No mm 2 No/mm mm mm mm kg/km RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 19
20 ADDISON Foam Skin PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened Multi RS 485 Databus Cables RE-02YS(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam Skin PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
21 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / ADDISON 21
22 ADDISON No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
23 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables RE-02YCH LSZH Outer Foam PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* ADDISON 23
24 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH /
25 Flame Retardant RS485 Databus Cables No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YCH / RE-02YCH / EIA/TIA /750V N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 25
26 ADDISON Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables RE-02YSCH LSZH Outer Foam Skin PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
27 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / ADDISON 27
28 ADDISON No. Strands No mm 2 No/mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
29 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02Y(St)H LSZH Outer Foam PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 29
30 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Pair Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H /
31 Flame Retardant RS485 Databus Cables No. Pair Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 31
32 ADDISON Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02YS(St)H LSZH Outer Foam Skin PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
33 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / ADDISON 33
34 ADDISON No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
35 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminium/polyester Tape & Copper Wire Braid Double Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02Y(St)CH Copper Wire Braid Foam PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 35
36 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminium/polyester tape+copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH /
37 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / RE-02Y(St)CH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 37
38 ADDISON Foam Skin PE Insulated, LSZH ed, Aluminium/polyester Tape & Copper Wire Braid Double Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02YS(St)CH Copper Wire Braid Foam Skin PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
39 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminium/polyester tape+copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / ADDISON 39
40 ADDISON No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02YS(St)CH / RE-02SY(St)CH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
41 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02Y(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize ADDISON 41
42 ADDISON crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf /
43 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 43
44 ADDISON Foam Skin PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02YS(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam Skin PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
45 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / ADDISON 45
46 ADDISON No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
47 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Copper Wire Braid Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02YCH LSZH Outer Foam PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* ADDISON 47
48 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH /
49 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 49
50 ADDISON Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened, Steel Wire Braid Armoured Multi RS 485 Databus Cables RE-02YSCH LSZH Outer Foam Skin PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
51 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armour: Steel Wire Braid Armoured. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / ADDISON 51
52 ADDISON No. Strands Steel Wire Braid Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
53 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables RE-02Y(St)H LSZH Outer Foam PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 53
54 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H /
55 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / RE-02Y(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 55
56 ADDISON Foam Skin PE Insulated, LSZH ed, Aluminum/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables RE-02YS(St)H LSZH Outer Foam Skin PE Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE No Corrosive Gas Emission Minimum Smoke Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
57 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. screen: Aluminum/polyester tape with tinned copper drain wire. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / ADDISON 57
58 ADDISON No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / RE-02YS(St)H / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
59 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Aluminium/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables RE-02Y(St)CHGSWAH Copper Wire Braid LSZH Inner Foam PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire Galvanized Steel Wire Armour LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* ADDISON 59
60 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Aluminium/polyester tape + copper wire braid. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH /
61 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / RE-02Y(St)CHGSWAH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 61
62 ADDISON Foam Skin LSZH Insulated, PE ed, Aluminium/polyester Tape Screened, Galvanized Steel Wire Armoured Multi RS 485 Databus Cables RE-02Y(St)CHGSWAH Copper Wire Braid LSZH Inner Foam Skin PE Stranded Tinned Copper Aluminium/polyester Tape With Tinned Copper Drain Wire Galvanized Steel Wire Armour LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
63 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Aluminium/polyester tape + copper wire braid(90% coverage). Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour ADDISON No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH /
64 ADDISON No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / RE-02YS(St)CHGSWAH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
65 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened Multi RS 485 Databus Cables RE-02Y(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. ADDISON 65
66 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf /
67 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / RE-02Y(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 67
68 ADDISON Foam Skin PE Insulated, LSZH ed, Individual Aluminium/polyester Tape & Copper Wire Braid screened Multi RS 485 Databus Cables RE-02YS(St)H pimf Individual AL/Polyester Tape With Tinned Copper Drain Wire Foam Skin PE Stranded Tinned Copper Copper Wire Braid LSZH Outer APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
69 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / ADDISON 69
70 ADDISON No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / RE-02YS(St)H pimf / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
71 Flame Retardant RS485 Databus Cables Foam PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables RE-02YCH LSZH Outer Foam PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard. EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* ADDISON 71
72 ADDISON CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH / RE-02YCH /
73 Flame Retardant RS485 Databus Cables No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YCH / RE-02YCH / RE-02YCH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN ADDISON 73
74 ADDISON Foam Skin PE Insulated, LSZH ed, Copper Wire Braid Screened Multi RS 485 Databus Cables RE-02YSCH LSZH Outer Foam Skin PE Stranded Tinned Copper Copper Wire Braid APPLICATION The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one the highest levels screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS Basic design adapted to EIA/TIA 485 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN ; IEC ; BS EN ; VDE ; NBN C (cat. F1); NF C (C2); CEI 20-35/1-2; EN *; DIN VDE * EN (cat. C); IEC ; BS EN ; VDE ; NBN C (cat. F2); NF C (C1); CEI 20-22/3-4; EN *; DIN VDE IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission IEC ; EN ; DIN VDE ; CEI 20-37/2-2 ; BS * Minimum Smoke Emission IEC &2; EN &2; DIN VDE &2; CEI 20-37/3-1&2; EN &2*; BS &2* No Toxic gases NES ; NF C Note: Asterisk * denotes superseded standard
75 Flame Retardant RS485 Databus Cables CABLE CONSTRUCTION Conductors: tinned copper wire, stranded according to IEC(EN) class 2. : Foam skin PE. Cabling Elements: Insulated cores are twisted to form s with varying lay length to minimize crosstalk. Two cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Screen: Copper wire braid. Inner : Thermoplastic LSZH compound. Armoured: Galvanized steel wire. Outer : Thermoplastic LSZH compound type LTS3 as per BS (Thermosetting LSZH compound type SW2-SW4 as per BS can be fered.) UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be fered as option. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -20 C C Temperature range during installation (mobile state): -5 C C Minimum bending radius: 8 x Electrical Properties Dielectric test Impedance Capacitance 2000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120Ω 45 nf/km conductor to conductor 90 nf/km conductor to shield CONSTRUCTION PARAMETERS No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / ADDISON 75
76 ADDISON No. Strands Steel Wire Armour No mm 2 No/mm mm mm mm mm kg/km RE-02YSCH / RE-02YSCH / RE-02YSCH / RE-02YSCH / /750V EIA/TIA 485 N Rated Voltage Standard Flame Retardancy NF C (C2) IEC /EN NF C (C1) IEC EN Zero Low Toxicity NES /NF C Low Corrosivity IEC EN /3 NF C Low Smoke Emission IEC &2 EN &2/NF C IEC EN
77 Flame Retardant RS485 Databus Cables TYPE CODES RE-A-B-C-D Outer H: LSZH Armour GSWA: Galvanized steel wire armour SWB: Steel Wire Braid Screen St: Aluminum tape C: Copper braid 02Y: Foam PE 02YS: Foam Skin PE ADDISON 77
78 ADDISON Technical Information FLAME RETARDANCE IN ACCORDANCE with DIFFERENT STANDARDS The following standards specify a method for flame propagation test for single core cables. The single cable sample undergoes the flame action a bunsen burner. The test only lasts few minutes. The IEC standards are taken over as EN standards and transferred to national standards Example: IEC becomes EN and introduced in Germany as DIN EN Flame Retardance in accordance with EN 60332:2004 EN 60332:2004 Tests on electrical and optical cables under fire conditions. The standard applies to single insulated wires (cables) and requires a vertical flame test with a maximum flame climb 450mm. The test lasts between 1 and 8 minutes, depending on the cable diameter. EN :2004 / BS EN :2004 / IEC :2004 / DIN EN :2004 / VDE : Test on electrical and optical cables under fire conditions. Test for a vertical flame propagation fo a single insulated wire or cables. EN :2004 / BS EN :2004 / IEC :2004 / DIN EN :2004 / VDE : / CEI ( CEI 20-35/1-2 ) Tests on electrical and optical fiber cables under fire conditions. Test for a vertical flame propagation for a single insulated wire or cable Procedure for 1kW premixed flame. This standard specifies a method test for resistance to vertical flame propagation for a single insulated wire or cable. Part 1-1 specifies the test apparatus and Part 1-2 specifies the test procedure. The cable sample is deemed to pass the test if the distance between the lower edge the top support and the onset charring is greater than 50mm. In addition, a failure shall be recorded if burning extends downward to a point greater than 540mm from the lower edge the top support. EN :2004 specifies the use 1kW premix flame and is for general use, except that the procedure may not be suitable for the testing small insulated conductors or cables less than 0.5mm sq cross section because the conductor melts before the test is completed, or for the testing small optic fiber cables because the fiber will be broken before the test is completed. In this case, the procedure given by EN /2 is recommended. EN :2004 / BS EN :2004 / IEC :2004 / DIN EN :2004 / VDE : Tests on electrical and optical cables under fire conditions. Test for a vertical flame propagation for a single small insulated wire or cable. EN :2004 / BS EN :2004 / IEC :2004 / DIN EN :2004 / VDE : / CEI (CEI 20-35/2-2) Test on electric and optical fiber cables under fire conditions. Tests for vertical flame propagation for a single small insulated wire or cable. Procedure for diffusion flame. This test applies to small dimensions cables. This standard specifies a method test for resistance to vertical flame propagation for a single insulated wire or cable. Part 2-1 specifies the test apparatus and Part 2-2 specifies the test
79 Technical Information procedure. Flame retardance in accordance with NF C (C2) NF C32-070:2001 Insulated conductors and cables for installation - Classification tests on conductors and cables with regard to fire behavior. NF C Procedure for 1 kw pre-mixed flame. The NF F (Category C2) and IEC are very similar. The sole difference is the time during which the flame is applied. Flame retardance in accordance with EN :1999 (replaced by EN 60332) EN :1999 / BS EN :1999 / DIN EN :1999 / VDE : Common test methods for cables under fire conditions. Test for resistance to a vertical flame propagation for a single insulated conductor or cable. Apparatus (Replaced by EN :2004 and EN :2004). EN :1999 / BS EN :1999 / DIN EN :1999 / VDE : Common test methods for cables under fire conditions. Test for resistance to a vertical flame propagation for a single insulated conductor or cable. Part 2-1: Procedure 1kW pre-mixed flame (Replaced by EN :2004). EN :1999 / BS EN :1999 / DIN EN :1999 / VDE : Common test methods for cables under fire conditions. Test for resistance to a vertical flame propagation for a single insulated conductor or cable. Part 2-2: Procedure Diffusion flame (Replaced by EN :2004). Flame Retardance in accordance with BS 4066 Part 1 & 2 (replaced by EN 60332) BS :1980 (superseded) Tests on electic cables under fire conditions. Method test on a single vertical insulated wire or cable. This standard is no longer in force and is replaced by BS EN which was also superseded by BS EN :2009. Flame retardance in accordance with NBN C (cat. F1) NBN C specifies a method test for measuring the vertical flame propagation characteristics a single wire or cable. The cable specimen is deemed to have passed the test and categorized as F1 if after burning has ceased, the charred or affected portion does not reach within 50mm the lower edge the top clamp which is equivalent to 425mm above the point flame application. Flame retardance in accordance with IEEE 383 In the IEEE 383 test, cables are supported by a one foot wide vertical rack eight feet high. The cables are positioned in the centre six inches the rack, spaced one-half diameter apart. The rack is centered in an eight foot enclosure. A ten inch ribbon burner ignites the cable with a 21 kw (70000 BTU). The burner is positioned 2 feet above the floor and 9 to 12 inches cables are exposed to direct flames for 20 minutes. Cables on which flame extends above the top the 8 foot rack fail the test. ADDISON 79
80 ADDISON In Accordance With Different Standards These standards specify a method for fire propagation test for vertically mounted bunched cables. These tests simulate the chimney effect in vertical installation bunch cables. A certain number cable sections with a length 3.5 m is fastened to a vertical ladder in an adapted chamber. The amount combustible materials for cables and duration flame application depends on the category the cable has to meet. Resistance the wires bundle arranged vertically to the spread the flame should be such that after a certain time and stopping the source ignition, flame is extinguished by itself and the length charred fragments will not exceed 2.5 m in height measured above the lower edge the burner. in accordance with IEC This test is the most common one to verify the behaviour a cables for the fire propagation. The cables are installed on a bunch vertical ladder inside a metal cabinet and undergo the action a ribbon flame at 750 C.The standard is subdivided in several parts that differ one from the other for the quantity cable to be installed, the installation mode and the flame application time. EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN :2009 / VDE : Common test methods for cables under fire conditions. Tests on electric and optical fiber cables under fire conditions - Part 3-10: Test for vertical flame spread vertically mounted bunched wires or cables. EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN / VDE : / CEI EN :2009 (CEI 20-22/3-1) Procedures. Tests on electric and optical fiber cables under fire conditions - Part 3-21: Test for vertical flame spread verticallymounted bunched wires or cables - Category A. F/R -Installation In one layer (front). -Installation In two layers (front and rear) -The quantity the Installed cable is equal to 7 litres/m combustible materials for cables -The time application the flame is 40 minutes EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN :2009 /VDE : / CEI EN :2009 (CEI 20-22/3-2) Procedures. Tests on electric and optical fiber cables under fire conditions - Part 3-22: Test for vertical flame spread vertically-mounted bunched wires or cable - Category A -Installation In one layer (front). -The quantity the installed cable is equal to 7 litres/m combustible materials for cables -The time application the flame is 40 minutes EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN :2009 / VDE : / CEI EN :2009 (CEI 20-22/3-3) Procedures. Tests on
81 Technical Information / VDE : / CEI EN :2009 (CEI 20-22/3-3) Procedures. Tests on electric and optical fiber cables under fire conditions - Part 3-23: Test for vertical flame spread vertically-mounted bunched wires or cables - Category B -Installation In one layer (front). -The quantity the installed cable is equal to 3.5 litres/m combustible materials for cables -The time application the flame is 40 minutes EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN :2009 / VDE : / CEI EN :2009 (CEI 20-22/3-4) Procedures. Tests on electric and optical fiber cables under fire conditions - Part 3-24: Test for vertical flame spread vertically-mounted bunched wires or cables - Category C -Installation In one layer (front). -The quantity the installed cable is equal to 1.5 litres/m combustible materials for cables -The time application the flame is 20 minutes EN :2009 / BS EN :2009 / IEC ed1.1 / DIN EN : 2009 / VDE : / CEI EN :2009 (CEI 20-22/3-5) Procedures. Tests on electric and optical fiber cables under fire conditions - Part 3-25: Test for vertical flame spread vertically-mounted bunched wires or cables - Category D -Installation In one layer (front). -The quantity the installed cable is equal to 0.5 litres/m combustible materials for cables -The time application the flame is 20 minutes. Summary test condition: IEC BS EN CEI 20-22/ / / / /3-5 Category AF/R A B C D Conductor crosssectionsmm >35 >35 35 >35 35 >35 35 > NMV(Iitres per metre cable) Minimum length test pieces(m) Standard ladder (500 mm wide): number layers maximum width test sampie 1front+1rear 300mm 1front 300mm 1front 300mm - - 1front 300mm 1front 300mm 1front 300mm 1front 300mm 1front 300mm ADDISON 81
82 ADDISON Wide ladder (800 mm wide): number layers maximum width test sampie Positioning test pieces Spaced 0.5 Touching cable (Max.20mm) - - 1front 600mm Spaced 0.5 cable (Max.20mm) Touching - - Spaced Spaced Touching cable cable (Max.20mm) (Max.20mm) Touching Number burners Ladder mounting Front and rear Front, Wider ladder for larger cables Front Front Front Flame application time(min) Test conditions Wind speed: <8 m/s; Ternperature: 5 C C Extent the 2.5m above the bottom edge the burner, neither at the front nor at the rear the ladder. charred portion Reduced fire propagation in accordance with NF C (C1) NF C :2001 Insulated conductors and cables for installation. -Classification tests on conductors and cables with regard to fire behavior. A 1600mm vertically installed bundled cable is exposed to the effects a radiating oven (approx 830 C) and forced ventilation. Pilot flames arranged above the oven burn f the emitted gases. The test duration is 30 minutes, with the ventilation stopped for every 10 minutes during the flame application period. The cable sample is classified under Category C1 according to NF F if the carbonised part the cable sample does not extend more than 0.8m above the upper base the oven. Depending on the damaged length, they can be further classified into 4 classes A, B, C and D according to NF F as follows: Category Test Result A No damaged length from top the oven in upper position. B Damaged length from top oven in upper position not extending more than 50mm. C Damaged length from top oven in upper position not extending more than 300mm Damaged length from top oven in upper position not extending above the top D the chimney Reduced fire propagation in accordance to EN , EN , EN , EN EN :2001 / BS EN :2001 / DIN EN :2001 / VDE : Common test methods for cables under fire conditions. Test for vertical flame spread vertically mounted bunched wires or cables - Part 1: Apparatus (Replaced by EN :2009) EN :2001 / BS EN :2001 / DIN EN :2001 / VDE : / CEI EN Common test methods for cables under fire conditions. Test for vertical flame
83 Technical Information spread vertically mounted bunched wires or cables - Part 2-1 : Procedures. Category A F/R (Replaced by EN :2009) EN :2001 / BS EN :2001 / DIN EN :2001 / VDE : / CEI EN Common test methods for cables under fire conditions. Test for vertical flame spread vertically mounted bunched wires or cables - Part 2-2: Procedures. Category A (Replaced by EN :2009) EN :2001 / BS EN :2001 / DIN EN :2001 / VDE : / CEI EN Common test methods for cables under fire conditions. Test for vertical flame spread vertically mounted bunched wires or cables - Part 2-3: Procedures. Category B (Replaced by EN :2009) EN :2001 / BS EN :2001 / DIN EN :2001 / VDE : / CEI EN :2001 Common test methods for cables under fire conditions. Test for vertical flame spread vertically mounted bunched wires or cables - Part 2-4: Procedures. Category C (Replaced by EN :2009). Reduced fire propagation in accordance with BS BS :1994 (superseded) Tests on electic cables under fire conditions. Tests on bunched wires or cables. This standard is no longer in force and is replaced by the BS EN :2001 Reduced fire propagation in accordance with NBN C (F2) NBN C specifies a method test for measuring the vertical flame propagation characteristics a bunch cables. The cable specimen is deemed to have passed the test and categorized as F2 if after burning has ceased, the extent charred or affected portion does not reach a height exceeding 2.5m above the bottom edge the burner. HALOGEN CONTENT TEST IN ACCORDANCE With DIFFERENT STANDARDS In the event a fire, many fumes are produced. This test is concerned with the possibilities corrosive acid gases being released from halogen containing cables and the damage such cables can cause (to equipments). These standards specify a method for determination the amount halogen acid gas, evolved during combustion compound. Halogen content test in accordance with EN EN :1998 / BS EN :1999 / DIN EN :1999 / VDE : / CEI EN :1999 (CEI 20-37/2-1) Common test methods for cables under fire conditions- Test on gases evolved during combustion materials from cables- Part 2-1: Procedures. Determination the amount halogen acid gas. This part the standard defines the method to measure the amount halogen acid evolved and which should be expressed in hydrochloric acid. The amount halogen acid contained in the test solution is determined by a titration method. ADDISON 83
84 ADDISON If the cables are described as zero halogen or halogen free, it is recommended that the hydrochoric acid yield should be less than 0.5%. Halogen content test in accordance with IEC IEC ed 2.0 Common test methods for cables under fire conditions. Test on gases evolved during combustion materials from cables. Part 1: Procedures. Determination the amount halogen acid gas. Basically, this is same as EN Halogen content test in accordance with BS BS :1990(superseded): Test on gases evolved during the combustion materials from cables. Method for determination amount halogen acid gas evolved during combustion polmeric materials taken from cables. This standard is no longer in force and is replaced by the EN Acid Gas Emission TEST In Accordance With Different Standards The following standards specify a method for determination acidity gas evolved during combustion cables by measuring PH and conductivity. This test allows to determine the corrosivity the acid gases generally halogens, that develop during the electric cable combustion. Acid Gas Emission Test in accordance with EN EN :1999 / BS EN :1999 / DIN EN :1999 / VDE : / CEI EN :1999 (CEI 20-37/2-2). Common test methods for cables under fire conditions- Test on gases evolved during combustion materials from cables- Part 2-2: Procedures. Determination degree acidity gases for materials by measuring PH and conductivity The standard states that the ph and the conductivity a test solution should be measured, using calibrated PH and conductivity meters. If the cables are described as zero halogen or halogen free, it is recommended that at least both the following requirements should be met for each the individual materials a cable: -The PH value should not be less than 4.3 when related to 1 litre water -The conductivity should not be less than 10us/mm when related to 1 litre water EN :1999 / BS EN :1999 / DIN EN :1999 / VDE : / CEI EN :1999 (CEI 20-37/2-3). Common test methods for cables under fire conditions- Test on gases evolved during combustion materials from cables- Part 2-3:Procedures. Determination degree acidity gases for cables by determination the weighted average ph and conductivity. The standard states that the ph and the conductivity a test solution should be measured, using calibrated ph and conductivity meters. The results from the different components the cable are then weighted
85 Technical Information Acid Gas Emission Test in accordance with IEC IEC ed1.0 Test on gases evolved during combustion electric cables - Part 2 : Determination degree acidity gases evolved during combustion materials taken from electric cables by measuring ph and conductivity. Acid Gas Emission Test in accordance with NF C NF C Common test methods for cables under fire conditions - Test on gases evolved during combustion materials from cables. This standard is equivalent to IEC Acid Gas Emission Test in accordance with BS BS :1993 (superseded) test on gases evolved during the combusion materials from cables. Determination degree acidity (corrosivity) gases by measuring ph and conductivity. This standard is no longer in force and is replaced by the EN :1999. Acid Gas Emission Test in accordance with DIN VDE / VDE :1994 DIN VDE / VDE :1994 Corrosivity combustion gases. The standards are no longer in force and are replaced by the EN & VDE SMOKE DENSITY TEST IN ACCORDANCE WITH DIFFERENT STANDARDS The smoke density measurement taken from a material under fire conditions gives an indication the visibility through the smoke. This is important as reduced visibility in a real fire situation makes it more difficult to escape from the fire thus increasing the threat to human life from the toxic gas, fumes and heat The following standards specify the method for measuring the generation smoke from cables during fire. Smoke Density Test in accordance with IEC & IEC IEC :2005 / EN :2005 / BS EN :2005 / DIN EN :2006 / VDE :2006 Measurement smoke density cables burning under defined conditions. Part 1: Test apparatus IEC :2005 / EN :2005 / BS EN :2005 / DIN EN :2006 / VDE :2006 / CEI EN :2006 (CEI 20-37/3-1) Measurement smoke density cables burning under defined conditions. Part 2: Test procedure and requirements. The standard specifies a method measurement smoke density cables. Part 1 specifies the test apparatus and Part 2 specifies the test procedure. The test is usually performed inside a chamber 3m x3m x3m and the test is sometimes described as 3 metre cube test. The test is performed by monitoring the tranmittance reduction a white light beam, running from one side the chamber to the other, at a set height, thus monitoring the build up smoke inside the chamber. The minimum percentage light transmittance is ten used to determine if the cable has passed or failed the test, ten a minimum light transmittance 60% is ADDISON 85
86 ADDISON applied in order to classify a cable as low smoke. Smoke Density Test in accordance with NF C NF C Common test methods for cables under fire conditions. - Measurement smoke density cables burning under defined conditions. This standard is equivalent to IEC Smoke Density Test in accordance with BS & BS BS :1993 (superseded) Measurement smoke density electric cables burning under defined condiitions. Test apparatus. BS :1993 (superseded) Measurement smoke density electric cables burning under defined condiitions. Test procedure and requirements. The standards are no longer in force and were replaced by the EN :2000 and EN :2000 even though they too were superseded by EN :2005 and EN :2005. Smoke Density Test in accordance with EN & EN EN :2000 / BS EN :2000 / DIN EN :2000 / VDE :2000 (superseded) Common test methods for cables under fire conditions. Measurement smoke density cable burning under defined conditions. Part 1: Apparatus EN :2000 / BS EN :2000 / DIN EN :2000 / VDE :2000 (superseded) Common test methods for cables under fire conditions. Measurement smoke density cable burning under defined conditions. Part 2: Procedure. The standards are no longer in force and are replaced by the EN :2005 and EN :2005. Although these standards have been withdrawn, they are still called upon in some specification documents such as in the London Underground specification Smoke Density Test In Accordance with Din Vde / Vde :1994 DIN VDE /VDE :1994 Testing cables, wires and flexible cords. Smoke Density. The standards are no longer in force and are replaced by the EN , VDE , EN & VDE which are also replaced by the EN :2005 and EN :2005. Oxygen Index TEST in accordance with different standards The oxygen index is defined as the minimum concentration oxygen, expressed as volume percentage, in a mixture oxygen and nitrogen that will just support combustion a material initially at room temperature under specified test conditions. Oxygen Index Test in accordance with ASTM D 2863 ASTM D Measuring the minimum oxygen concentration to support candle-like combustion plastics (Oxygen Index). The test is performed in accordance with the procedure specified in ASTM using test piece cut from the outer sheath the cable. The apparatus holds a small specimen which is clamped vertically in a tube in an atmosphere where the relative concentration oxygen and nitrogen can be changed. The aim is to test the flammability the sample with a small pilot flame to find the
87 Technical Information minimum oxygen concentration required to just sustain combustion the sample. Oxygen Index Test in accordance with ISO ISO4589-2:1996 Determination burning behaviour by oxygen index Part 2: Ambient temperature test. Specimens measuring 100mm long by 6mm wide are used for testing. The test is performed in accordance with the procedure specified in the standard. Temperature Index Test in accordance with different standards This is a test for assessing the performance a material when it is tested in accordance with BS2782: Part 1: Method 143a and 143b. The oxygen index a material will drop when the temperature rises. When the temperature rises and the oxygen index drops to 21%, the material will burn automatically. This temperature is defined as temperature index. For example, the oxygen index the coal at room temperature is 50% and when the temperature climbs to 150 C, it s oxygen index drops to 21 C and the coal will burn by itself automatically. The temperature index the coal is defined as 150 C. In general, the temperature index fire retardant cable exceeds 250 C. Temperature Index Test in accordance with BS 2782 BS 2782: Part 1:1989 Method 143a and 143b Temperature materials. Determination flammability. Specimens measuring nominally 100mm long by 6.5mm wide by 3mm thick are used for testing. The specimens are then tested in accordance with the test procedure specified in the standard. Temperature Index Test in accordance with ISO ISO4589-3:1996 Determination burning behaviour by oxygen index Part 3: Elevated temperature test. Specimens measuring 100mm long by 6mm wide are used for testing. The test is performed in accordance with the procedure specified in the standard. ToxicITY TEST in accordance with different standards Toxicity test in accordance with NES Measuring a fume from a material exposed to a controlled fire conditions gives an indication the fumes which may be produced in a real fire situation. A standard method test for determining the toxicity materials under fire condition is Defense Standard NES Toxicity. This method gives the level toxicity the fumes produced from the material under test. During the test, the test specimen is heated via direct flame application at 1150 C. The flame is applied via a bunsen burner with a flame height between 100m and 125mm formed with a methane gas and an external supply compressed air. The specimen toxicity is determined from accurate pre-analysis weight (4pp) colorimetric tubes and ion chromatography. ADDISON 87
88 ADDISON The test may determine the following species: Hydrogen Bromide, Hydrochloric Acid, Hydrogen Fluoride, Formaldehyde, Nitrous gases, Carbon Monoxide, Carbon Dioxide, Acrylonitrile, Phenol, Hydrogen Sulphide, Sulphur Dioxide, Hydrocyanic Acid, Ammonia. The concentration in ppm for each gas detected are provided. The toxicity index the speciments summates the toxic gases, taking into account their level danger to humans. The smaller the toxicity index, the better the product. A limit 5 is ten applicable. Toxicity test in accordance with NF C NF C base environmental testing procedures. Fire behaviour. Analysis and titration gases evolved during pyrolysis or combustion materials used in electrotechnics. Exposure to abnormal heat or fire. Tube furnace method. The test defined by this standard serves to define the conventional toxicity index (cti) the gases emitted by the insulating or sleeving materials during combustion at 800 C. Toxicity test in accordance with NF X NF X Fire Tests; Analysis gaseous effluents. The test is conducted within a tube furnace where the temperature is set at either 400 C, 600 C, 800 C (commonly 600 C is used for most the materials or 800 C for some electrical products) for 40 minutes throughout the test by analysis the toxicity index the gases including CO, CO 2, HCL, HBr, HCN, HF and SO
89 Technical Information Address: Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UK Tel: 44(0) Fax: 44(0) ADDISON 89
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5
Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5 Caledonian Windmill Cables COMPANY PROFILE Table of Content Caledonian, established in 1978, offers one of the
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
Copper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
EXAMPLE OF RELEVANT STANDARDS
Optical Cables Electronics market NEXANS a n d Th e El e c t r o n i c s Ma r k e t Nexans products offer a high technology knowledge and an international know-how, which has been experienced in different
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
VDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
Commercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
B05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
C 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
Catalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
FIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
Bare copper complying with CEI EN 60228 (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red
SPECIAL CABLES xed installation BUS 0F Conduttore Conductor Isolamento ed cazione anime Insulation and core cation Rame rosso secondo CEI EN 08 (CEI 0-) classe PE espanso con skin in HDPE. Anime colorate
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
Comprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
OPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
The Quality Connection. Cables for Data Transmission in Industrial Automation
The Quality Connection Cables for Data Transmission in Industrial Automation Product range Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
BUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation
SPECIAL CABLES BUS 00F Cavo per posa fissa (INTERBUS Remote Bus, -wire) INTERBUS cable for fixed installation UNIKA BUS 00F c us AWM style 79 80 C 000V FT- Conduttore Conductor Isolamento ed identificazione
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Copper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
LOW VOLTAGE POWER CABLES
LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
Exane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.
Communication cables and burning behaviour international regulations Different regulations and standards apply depending on the geographic location. Europe is normally governed by CENELEC (EN), but in
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
MV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
Cable 101: Introduction to Belden Wire & Cable Company
Cable 101: Introduction to Belden Wire & Cable Company Presented By: Belden Engineering Center Staff Belden Wire & Cable Company OVERVIEW Who is Belden? Belden is a world leader in the field of signal
Servo Motor & Drive Cables
Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
MacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
Fire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
CURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
Coaxial cables? Video cables Loudspeaker cables
Photo: ELUKABEL Coaxial cables? Video cables Loudspeaker cables Coaxial cables? Video cables Loudspeaker cables Coaxial cables are used in all areas of the high frequency transmission technology, for example
THE IMPORTANCE OF HIPOT ISOLATION ON INDUSTRIAL ETHERNET SWITCHES
THE IMPORTANCE OF HIPOT ISOLATION ON INDUSTRIAL ETHERNET SWITCHES THE IMPORTANCE OF HIPOT ISOLATION ON INDUSTRIAL ETHERNET SWITCHES What is Hipot? HIPOT is the short term for high potential (high voltage).
CLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
The best connection in plant engineering Industrial Projects
The best connection in plant engineering Industrial Projects The Quality Connection 2 The optimum solution for any plant. LEONI Business Unit Industrial Projects your expert for a market that requires
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
MarineTuff Offshore and Marine Cable Solutions
Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,
The Instrumentation Cable Experts
1 The Instrumentation Cable Experts Facilities Head office & factory 1300 Industrial Boulevard Mt Pleasant, Texas 75455, USA www.dekoroncable.com Stocking Centres USA Mt Pleasant and Houston Singapore
LT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
