Direct solenoid and solenoid pilot operated valves
|
|
- Jonas Cross
- 7 years ago
- Views:
Transcription
1 Direct solenoid and solenoid pilot operated valves Individual mounting Series non plug-in plug-in Manifold mounting 35 non plug-in plug-in 100 onded spool Indicator light Manual operator Large piston assembly Encapsulated solenoid ir/spring return 45 External pilot supply port alanced poppet SERIES FETURES Unique patented MCSOLENOID for fastest possible response times. alanced poppet pilot valve for high flow, precise repeatability, and consistent operation. Large spool piston for maximum shifting force even at minimum operating pressure. ir/spring return for consistent shifting on single solenoid models. MC spool and bore combination for wiping away contamination, eliminating sticking, and use on non-lube service. Patented virtually burn-out proof C solenoid. Plug-in design of valves, bases, flow controls, and regulators for modular assembly and ease of maintenance. Optional low wattage DC solenoids down to 1.8 watts. Indicator lights in valve body or base and non-plug-in models available. Very high flow in a very compact package. 99 Consult Precautions page 364 before use, installation or service of MC Valves ISO 1 ISO 2 ISO 3 MC 125 MC 250 MC 500
2 100% 100% WRRNTY 18 OF PRODUCTION TESTED 100% MONTHS SPOOL CONFIGURTIONS SGLE OPERTOR SGLE LET - DUL UST SHOWN WITH OPERTOR ENERGIZED DOULE OPERTOR SGLE LET - DUL UST SHOWN WITH OPERTOR ENERGIZED SGLE OPERTOR DUL LET - SGLE UST SHOWN WITH OPERTOR ENERGIZED DOULE OPERTOR DUL LET - SGLE UST SHOWN WITH OPERTOR ENERGIZED 3 POSITION CLOSED CENTER 3 POSITION OPEN CENTER 3 POSITION SGLE PRESSURE PRESSURE CENTER 3 POSITION DUL PRESSURE PRESSURE CENTER 100 Consult Precautions page 364 before use, installation or service of MC Valves
3 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series - 1/8-1/4-3/ C v non plug-in OPERTIONL ENEFITS 1. alanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. onded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Port size Pilot air Single operator Double operator Closed center Open center Pressure center Valve less base Internal 1/8 NPTF External TM-DXXX-XXX 82---TM-DXXX-XXX 82--D-TM-DXXX-XXX TM-DXXX-XXX 82---TM-DXXX-XXX 82--D-TM-DXXX-XXX 82-E-000-TM-DXXX-XXX 82-E--TM-DXXX-XXX 82-E-D-TM-DXXX-XXX 82-F-000-TM-DXXX-XXX 82-F--TM-DXXX-XXX 82-F-D-TM-DXXX-XXX 82-G-000-TM-DXXX-XXX 82-G--TM-DXXX-XXX 82-G-D-TM-DXXX-XXX 45 Internal 82---TM-DXXX-XXX 82---TM-DXXX-XXX 82-E--TM-DXXX-XXX 82-F--TM-DXXX-XXX 82-G--TM-DXXX-XXX 1/4 NPTF External 82--D-TM-DXXX-XXX 82--D-TM-DXXX-XXX 82-E-D-TM-DXXX-XXX 82-F-D-TM-DXXX-XXX 82-G-D-TM-DXXX-XXX 3/8 NPTF Internal External 82--C-TM-DXXX-XXX 82--CD-TM-DXXX-XXX 82--C-TM-DXXX-XXX 82--CD-TM-DXXX-XXX 82-E-C-TM-DXXX-XXX 82-E-CD-TM-DXXX-XXX 82-F-C-TM-DXXX-XXX 82-F-CD-TM-DXXX-XXX 82-G-C-TM-DXXX-XXX 82-G-CD-TM-DXXX-XXX 700 SOLENOID OPERTOR D XX X- X XX * 900 XX Voltage X Wire length X Manual operator XX 120/60, 110/50 240/60, 220/50 C 24/60, 24/50 F 24 VDC (1.8 W) D 24 VDC (5.4 W) DF 24 VDC (12.7 W) * Other options available, see page 361. OPTIONS TM-DXXX-XXX TM-DXXX-XXX - For dual pressure valves, replace by C, by D, E by M, F by L, G by H. (Requires sandwich regulator, see pressure regulator section.) - TP (Piped pilot exhaust) - For pilot exhaust out main exhaust, replace by E. lso, TM pilot body is replaced by TU pilot body. - Main exhaust cannot be restricted. vailable only on single pressure valves. 82-XX--TM-DXXX-XXX - Replace by for bottom ports (1/8 or 1/4 only) - Replace by C for side and bottom ports (1/8 or 1/4 only) J 18 (Flying leads) Connector Non-locking 2 Locking K KD J JD Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Note : KD connector shown in photo. Consult Precautions page 364 before use, installation or service of MC Valves ISO 1 ISO 2 ISO 3 MC 125 MC 250 MC 500
4 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% M O N T H S technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : PSI double operator : PSI External pilot : vacuum to 150 PSI Single operator and 3 positions : PSI Double operator : PSI Not required, if used select a medium aniline point lubricant (between 180 F to 210 F) 40 µ 0 F to 120 F (-18 C to 50 C) 1/8 : (0.9 C v ), 1/4" : (1.3 C v ), 3/8" : (1.35 C v ) 200 cm 3 /min Epoxy encapsulated - class wires - Continuous duty. -15% to +10% of nominal voltage Consult factory Inrush : 10.9 V Holding : 7.7 V = 1.8 to 12.7 W 24 VDC (5.4 W) Energize : 9 ms De-energize : 6 ms 120/60 Energize : 5-12 ms De-energize :6-13 ms Spare parts : Options : dimensions Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXX-XXX, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : SPP threads. Flow controls (Part N. FC82-) Explosion-proof model. Dimensions shown are metric (mm) 149,0 DOULE OPERTOR 120,5 SGLE OPERTOR 149,0 DOULE OPERTOR 120,5 SGLE OPERTOR 4,5 27,5 24,0 OPTIONL SNDWICH FLOW CONTROLS 27,5 2 Ø 5,3 15,5 15,5 14,5 12,5 20,5 41,0 1/8-27 NPTF External pilot port 83,2 104,2 21,0 26,0 PILOT 22,0 21,0 80,0 26,0 47,3 CONDUIT CYL CYL 9,0 1/2-14 NPSM Conduit port 14,5 11,3 50,0 25,0 38,5 PILOT Port size 1/8 & 1/4 NPTF 19.5 mm 3/8 NPTF 17.0 mm 102 Consult Precautions page 364 before use, installation or service of MC Valves
5 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series - 1/8-1/4-3/ C v plug-in OPERTIONL ENEFITS 1. alanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. onded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Port size Pilot air Single operator Double operator Closed center Open center Pressure center Valve less base Internal 1/8 NPTF External TM-DXXP-XD 82---TM-DXXP-XD 82--D-TM-DXXP-XD TM-DXXP-XD 82---TM-DXXP-XD 82--D-TM-DXXP-XD 82-E-000-TM-DXXP-XD 82-E--TM-DXXP-XD 82-E-D-TM-DXXP-XD 82-F-000-TM-DXXP-XD 82-F--TM-DXXP-XD 82-F-D-TM-DXXP-XD 82-G-000-TM-DXXP-XD 82-G--TM-DXXP-XD 82-G-D-TM-DXXP-XD 45 Internal 82---TM-DXXP-XD 82---TM-DXXP-XD 82-E--TM-DXXP-XD 82-F--TM-DXXP-XD 82-G--TM-DXXP-XD 1/4 NPTF External 82--D-TM-DXXP-XD 82--D-TM-DXXP-XD 82-E-D-TM-DXXP-XD 82-F-D-TM--DXXP-XD 82-G-D-TM-DXXP-XD 3/8 NPTF Internal External 82--C-TM-DXXP-XD 82--CD-TM-DXXP-XD 82--C-TM-DXXP-XD 82--CD-TM-DXXP-XD 82-E-C-TM-DXXP-XD 82-E-CD-TM-DXXP-XD 82-F-C-TM-DXXP-XD 82-F-CD-TM-DXXP-XD 82-G-C-TM-DXXP-XD 82-G-CD-TM-DXXP-XD 700 SOLENOID OPERTOR D XX P- X D * 900 XX * Other options available, see page 361. OPTIONS Voltage 120/60, 110/50 240/60, 220/50 C 24/60, 24/50 F 24 VDC (1.8 W) D 24 VDC (5.4 W) DF 24 VDC (12.7 W) TM-DXXP-XD - For light in body replace by C. - For pilot exhaust out main exhaust replace by D. For light replace by F. Use TU pilot body for pilot exhaust to main exhaust, main exhaust cannot be restricted (NO flow controls) available with single pressure valve only. TU replaces TM. - For piped pilot exhaust replace TM by TP. - For dual pressure valves, replace by C, by D, E by M, F by L, G by H. (Requires sandwich regulator - see pressure regulator section) 82---TM-DXXP-XD - Replace by for bottom ports (1/8 or 1/4 only) - Replace by C for side and bottom ports (1/8 or 1/4 only) X 103 Manual operator 1 Non-locking 2 Locking Consult Precautions page 364 before use, installation or service of MC Valves ISO 1 ISO 2 ISO 3 MC 125 MC 250 MC 500
6 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% M O N T H S technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : PSI double operator : PSI External pilot : vacuum to 150 PSI Single operator and 3 positions : PSI Double operator : PSI Not required, if used select a medium aniline point lubricant (between 180 F to 210 F) 40 µ 0 F to 120 F (-18 C to 50 C) 1/8" : (0.9 C v ), 1/4 (1.3 C v ), 3/8" : (1.35 C v ) 200 cm 3 /min Epoxy encapsulated - class wires - Continuous duty. -15% to +10% of nominal voltage Consult factory Inrush : 10.9 V Holding : 7.7 V = 1.8 to 12.7 W 24 VDC (5.4 W) Energize : 9 ms De-energize : 6 ms 120/60 Energize : 5-12 ms De-energize :6-13 ms Spare parts : Options : Solenoid operator (power 5.4 W ) : DXXP-XD, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXP-XD, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : SPP threads. Flow controls (Part N. FC82-) Explosion-proof model. Lights in base. dimensions Dimensions shown are metric (mm) 149,0 DOULE OPERTOR 120,5 SGLE OPERTOR 3,9 (OPTION : light) 3,9 (OPTION : Light) 83,2 104,2 4,5 27,5 24,0 1/8-27 NPTF EXTERNL PILOT PORT 11,3 50,0 PILOT 25,0 22,0 OPTIONL SNDWICH FLOW CONTROLS 38,5 PILOT 27,5 2 Ø 5,3 21,0 26,0 47,3 1/2 NPSM 15,5 15,5 14,5 12,5 20,5 41,0 CONDUIT CYL CYL 14,5 21,0 26,0 Port size 1/8, 1/4 (OPTIONL OTTOM PORTS) 80,0 9,0 1/8-1/4 3/ Consult Precautions page 364 before use, installation or service of MC Valves
7 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series - 1/4-3/ C v non plug-in OPERTIONL ENEFITS 1. alanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. onded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Port size Pilot air Single operator Double operator Closed center Open center Pressure center Valve less base Internal 1/4 NPTF External TM-DXXX-XXX 82--K-TM-DXXX-XXX 82--KD-TM-DXXX-XXX TM-DXXX-XXX 82--K-TM-DXXX-XXX 82--KD-TM-DXXX-XXX 82-E-000-TM-DXXX-XXX 82-E-K-TM-DXXX-XXX 82-E-KD-TM-DXXX-XXX 82-F-000-TM-DXXX-XXX 82-F-K-TM-DXXX-XXX 82-F-KD-TM-DXXX-XXX 82-G-000-TM-DXXX-XXX 82-G-K-TM-DXXX-XXX 82-G-KD-TM-DXXX-XXX 45 Internal 82--CK-TM-DXXX-XXX 82--CK-TM-DXXX-XXX 82-E-CK-TM-DXXX-XXX 82-F-CK-TM-DXXX-XXX 82-G-CK-TM-DXXX-XXX 3/8 NPTF External 82--CKD-TM-DXXX-XXX 82--CKD-TM-DXXX-XXX 82-E-CKD-TM-DXXX-XXX 82-F-CKD-TM-DXXX-XXX 82-G-CKD-TM-DXXX-XXX SOLENOID OPERTOR D XX X - X XX * 700 XX Voltage X Wire length X Manual operator XX Electrical connection 120/60, 110/50 18 (Flying leads) 1 Non-locking K Square connector 240/60, 220/50 J Connector 2 Locking KD Square connectorwith light C 24/60, 24/50 J Rectangular connector F 24 VDC (1.8 W) JD Rectangular connector with D 24 VDC (5.4 W) light DF 24 VDC (12.7 W) Flying leads Note : KD connector shown in photo. * Other options available, see page 361. OPTIONS TM-DXXX-XXX - For pilot exhaust out main exhaust replace by E. lso, TM pilot body is replaced by TU pilot body. Main exhaust cannot be restricted (No flow controls) available with single pressure valve only. - For piped pilot exhaust replace TM by TP. - For dual pressure valves, replace by C, by D, E by M, F by L, G by H. (Requires sandwich regulator - see pressure regulator section) 82-XX-K-TM-DXXX-XXX - Replace K by L for bottom cyl. ports - Replace K by M for bottom inlet port - Replace K by N for bottom inlet and cyl. ports - Replace K by P for bottom and end cyl. ports - Replace K by R for bottom and end cyl. ports w/bottom inlet - Replace K by S for selector base with side ports 105 Consult Precautions page 364 before use, installation or service of MC Valves ISO 1 ISO 2 ISO 3 MC 125 MC 250 MC 500
8 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% M O N T H S technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : PSI double operator : PSI External pilot : vacuum to 150 PSI Single operator and 3 positions : PSI Double operator : PSI Not required, if used select a medium aniline point lubricant (between 180 F to 210 F) 40 µ 0 F to 120 F (-18 C to 50 C) 1/4 (1.3 C v ), 3/8" : (1.35 C v ) 200 cm 3 /min Epoxy encapsulated - class wires - Continuous duty. -15% to +10% of nominal voltage Consult factory Inrush : 10.9 V Holding : 7.7 V = 1.8 to 12.7 W 24 VDC (5.4 W) Energize : 9 ms De-energize : 6 ms 120/60 Energize : 5-12 ms De-energize :6-13 ms Spare parts : Options : dimensions Solenoid operator (power 5.4 W) : DXXX-XXX, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXX-XXX, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : Tie-rod (x2) : Fastening kit : N SPP threads. Flow controls (Part N. FC82-) Explosion-proof model. Dimensions shown are metric (mm) ,7 DOULE OPERTOR 164,2 SGLE OPERTOR 174,7 DOULE OPERTOR 164,2 SGLE OPERTOR 1 1/4 NPSM 9,0 COND 126,2 46,0 28,0 27,0 OPTIONL SNDWICH FLOW CONTROLS COND 17,5 59,0 1/8-27 NPTF (OPTIONL COMMON EXT. PILOT PORT) 26,5 47,0 164,2 3/8-4 PLCES 6,5 96,0 4,5 23,0 12,0 CYL CYL 37,0 22,5 46,0 ± 0,2 1/8 126,2 18,5 59,0 2 Ø 5,3 18,5 EXT PILOT CYL 105,2 36,0 60,5 23,0 16,0 CYL 14,0 COND 16 18,5 46,0 106 Consult Precautions page 364 before use, installation or service of MC Valves
9 Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Manifold mounting Series - 1/4-3/ C v plug-in OPERTIONL ENEFITS 1. alanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. onded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Port size Pilot air Single operator Double operator Closed center Open center Pressure center Valve less base Internal 1/4 NPTF External TM-DXXP-XD 82--K-TM-DXXP-XD 82--KD-TM-DXXP-XD TM-DXXP-XD 82--K-TM-DXXP-XD 82--KD-TM-DXXP-XD 82-E-000-TM-DXXP-XD 82-E-K-TM-DXXP-XD 82-E-KD-TM-DXXP-XD 82-F-000-TM-DXXP-XD 82-F-K-TM-DXXP-XD 82-F-KD-TM-DXXP-XD 82-G-000-TM-DXXP-XD 82-G-K-TM-DXXP-XD 82-G-KD-TM-DXXP-XD 45 Internal 82--CK-TM-DXXP-XD 82--CK-TM-DXXP-XD 82-E-CK-TM-DXXP-XD 82-F-CK-TM-DXXP-XD 82-G-CK-TM-DXXP-XD 3/8 NPTF External 82--CKD-TM-DXXP-XD 82--CKD-TM-DXXP-XD 82-E-CKD-TM-DXXP-XD 82-F-CKD-TM-DXXP-XD 82-G-CKD-TM-DXXP-XD SOLENOID OPERTOR D XX P- X D * 700 XX Voltage 120/60, 110/50 240/60, 220/50 C 24/60, 24/50 F 24 VDC (1.8 W) D 24 VDC (5.4 W) DF 24 VDC (12.7 W) * Other options available, see page 361. OPTIONS TM-DXXP-XD 82-XX-K-TM-DXXP-XD - Replace K by L for bottom cyl. ports - Replace K by M for bottom inlet port - Replace K by N for bottom inlet and cyl. ports - Replace K by P for bottom and end cyl. ports - Replace K by R for bottom and end cyl. ports w/bottom inlet - Replace K by S for selector base with side ports X 107 Manual operator 1 Non-locking 2 Locking - For light in body replace by C. - For pilot exhaust out main exhaust replace by D. For light replace by F. Use TU pilot body for pilot exhaust to main exhaust, main exhaust cannot be restricted (No flow controls) available with single pressure valve only. TU replaces TM. - For piped pilot exhaust replace TM by TP. - For dual pressure valves, replace by C, by D, E by M, F by L, G by H. (Requires sandwich regulator - see pressure regulator section) Consult Precautions page 364 before use, installation or service of MC Valves ISO 1 ISO 2 ISO 3 MC 125 MC 250 MC 500
10 100% 100% WRRNTY 18 O F P R O D U C T I O N T E S T E D 100% M O N T H S technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : PSI double operator : PSI External pilot : vacuum to 150 PSI Single operator and 3 positions : PSI Double operator : PSI Not required, if used select a medium aniline point lubricant (between 180 F to 210 F) 40 µ 0 F to 120 F (-18 C to 50 C) 1/4 (1.3 C v ), 3/8" : (1.35 C v ) 200 cm 3 /min Epoxy encapsulated - class wires - Continuous duty. -15% to +10% of nominal voltage Consult factory Inrush : 10.9 V Holding : 7.7 V = 1.8 to 12.7 W 24 VDC (5.4 W) Energize : 9 ms De-energize : 6 ms 120/60 Energize : 5-12 ms De-energize :6-13 ms Spare parts : Options : dimensions Solenoid operator (power 5.4 W) : DXXP-XD, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXP-XD, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : Tie-rod (x2) : Fastening kit : N SPP threads. Flow controls (Part N. FC82-) Explosion-proof model. Lights in base. Dimensions shown are metric (mm) 174,7 DOULE OPERTOR 164,2 SGLE OPERTOR 174,7 DOULE OPERTOR 164,2 SGLE OPERTOR 1 1/4 NPSM 46,0 28,0 9,0 COND 27,0 OPTIONL SNDWICH FLOW CONTROLS COND 126,2 17,5 1/8 (OPTIONL COMMON EXT. PILOT PORT.) 59,0 26,5 47,0 164,2 3/8-4 PLCES 6,5 96,0 4,5 23,0 12,0 CYL CYL 18,5 59,0 2 Ø 5,3 37,0 22,5 46,0 ± 0,2 EXT PILOT 1/8 105,2 126,2 18,5 CYL 36,0 60,5 23,0 16,0 CYL COND 16 14,0 18,5 46,0 108 Consult Precautions page 364 before use, installation or service of MC Valves
11 I n t r i n s i c a l l y S a f e V a l v e s HOW TO ORDER ODY OPTIONS SE OPTIONS PILOT VLVE 82 - XX - XXX - (XX - DXXX - XXX) SPOOL TYPE - VLVE FUNCTION 0 Individual base or manifold only Single Operator - single pressure Double operator - sinle pressure C Single operator - dual pressure D Double operator - dual pressure E 3-position closed center F 3-position open center G 3-position single pressure, pressure center H 3-position dual pressure,* pressure center J Single solenoid single pressure solenoid on end K Single solenoid dual pressure solenoid on end L 3-position dual pressure,* open center M 3-position dual pressure,* closed center * Note: For dual pressure w/o regulators consult factory. ODY TYPE Plug-in body Non Plug-in body D. & MNIFOLD SE PORT CONFIG. --Individ ual ase-- 0 Valve only - no base Standard side ports (1/8, 1/4, or 3/8 ) ottom ports only* C Side and bottom ports* D Side inlet, side exhaust, bottom cylinder ports* * ottom ports available in 1/8 & 1/4 only in individual base --Manifold ase-- K Standard ports (1/4 or 3/8 only) L ottom cylinder ports* M ottom inlet port N ottom inlet and cylinder ports* P ottom and end cylinder ports* R ottom cylinder & end cylinder ports w/bottom inlet port* S Selector base - standard side ports * ottom parts available in 1/4 & 3/8 only on manifold. ottom inlet available 1/4 only. For bottom O-ring ports, consult factory. T. OR EXT. PILOT* --Internal Pilot-- 0 Valve only - no base No light in base --External Pilot-- 0 Valve only - no base D No light in base * Use internal for main valve pressures of PSIG. Use external for main valve pressures of 28 Hg vacuum - 25 PSIG PILOT VLVE OPTIONS - (XX - DXXX - XXX) PORT SIZE - THRED TYPE 0 Valve only - no base 1/8 NPTF 1/4 NPTF C 3/8 NPTF D 1/8 SPPL E 1/4 SPPL F 3/8 SPPL PILOT UST F Muffled exhaust VOLTGE FR 12VDC (0,6w) FS 24VDC (0,6w) LED WIRE LENGTH --Plug-in Valve/ase-- P Plug-in 8 - standard Non Plug-in Valve/ase-- 18 E F 96 C 36 J 6 * D 48 * Lead wire length for external plug-in connectors must be J MNUL OPERTOR 0 No manual operator 1 Nonlocking operator 2 Locking operator 3 Nonlocking extended operator 4 Locking extended operator ELECTRICL CONN. --Plug-in Valve/ase-- D Plug-in (standard) --Non Plug-in Valve/ase-- Grommet C Conduit 1/2 NPS CM Metal conduit 1/2 NPS CN Metal conduit w/grd. 1/2 NPS --External Plug-in-- J Rectangular plug-in JM Rectangular male only K Mini plug-in KJ Mini plug-in male only T Dual tabs (.110) w/ receptables TJ Dual tabs (.110) w/o receptables HOW TO ORDER 82 SERIES FLOW CONTROL MODULE* FC 82- FC 82- Plug-in flow control assembly Non plug-in flow control assembly *If flow control module is to be installed between valve and base or valve and manifold at the factory, add -9 after the flow control model number, i.e., FC The flow control model number should follow the valve model number on which it is to be installed. 347 NOTE: Reference regulator ordering section if a sandwich regulator is required. NOTE: If a flow control assembly is used with the dual pressure regulator option, only the flow control on the end is functional. (Controls both cylinder ports.) Consult Precautions page 364 before use, installation or service of MC Valves
12 O p t i o n s O P T I O N S Codification table for voltages / Wire length / Manual operators / Electrical connections VLVE CODE - D XX X - X XX OPTIONS VILLE FOR - Solenoid valves 35, 45 and 82 Series 361 Consult Precautions page 364 before use, installation or service of MC Valves
13 O P T I O N S 1. VOLTGE - D XX X - X XX VOLTGE 120/60, 110/50 240/60, 220/50 C 24/60, 24/50 D 24/60 E 200/60 F 240/50 G 100/50, 100/60, 110/60 D 24 VDC (5.4 W) D 12 VDC (5.4 W) DC 12 VDC (7.5 W) DD 24 VDC (7.3 W) DE 12 VDC (12.7 W) - CLSFonly DF 24 VDC (12.7 W) - CLSF only DK 110 VDC (4.7 W) DL 64 VDC (6 W) DM 36 VDC (5.3 W) DN 6 VDC (6 W) DP 48 VDC (5.8 W) DU 24 VDC (6 W) E 12 VDC (6 W) F 12 VDC (1.8 W) F 24 VDC (1.8 W) FE 12 VDC (2.4 W) FF 24 VDC (2.4 W) 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH C 36 D 48 E 72 F 96 J For external plug-in connector ( J, K & T type electrical connection) P For plug-in valves (82 Series only) 362 Consult Precautions page 364 before use, installation or service of MC Valves
14 O p t i o n s O P T I O N S 3. MNUL OPERTOR - D XX X - X XX MNUL OPERTOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICL CONNECTION - D XX X - X XX ELECTRICL CONNECTION Flying leads K with protection diode L with protection varistor (M.O.V.) ** C 1/2" NPS conduit ** CM 1/2" NPS metal conduit ** CN 1/2" NPS metal conduit w/ground ** J Rectangular connector ** JD Rectangular connector with light ** JM Rectangular connector, male only K Square connector K Square connector with protection diode KC Square connector with protection varistor (M.O.V.) KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor (M.O.V.) KG Square connector with LED light & diode KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) (M.O.V.) *** M Electrical common conduit T Dual tabs T T with protection diode TD T with light TE T with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode D* Plug-in connector DK* D with protection diode DL* D with protection varistor (M.O.V.) FM Plug-in FN Plug-in with diode FP Plug-in with M.O.V. * To be used with 82 Series only ** Inline valves only for 35 & 45 series. No restrictions for 82 series. *** Stacking valves only for 35 & 45 series. Conduit end plate kit required, one per stack. 35 series : M series : M Consult Precautions page 364 before use, installation or service of MC Valves
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationsize 3 15 4200 size 4 19 6600
BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationValves. Sub-Base Mounted Valves to ISO 5599/2
Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationUM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
More information0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3
Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
More informationPILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V
PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationChapter 6: Check Valves
Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More information2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double
4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor
More informationDenotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY
Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,
More informationTable of Contents. MicroAir Series...3-9
Table of Contents MicroAir Series...-9 Technical and Operating Data.... How to Order.... Valve on ndividual Base... 5 Manifold Assemblies... 6 End Plate Kits... 7 Blank Station Plate Kit.... 7 Blocking
More informationUM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted
U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils
More information-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890
CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
More informationzamak nitrile rubber self-extinguishing technopolymer aluminum
PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationSafety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationDirectional Control Valves
echnical Information General he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationMiniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC
8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated
More informationDirect Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationKA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting
K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56
More informationD660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10
D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics
More informationElectro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationLoad-sensing control block in mono and sandwich plate design
Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420
More informationsolenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid
2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls
More informationSPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4
SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves
BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationChapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationCoil Classification: Class F standard, Class H available Class B standard on V9xx models
Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationWHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationNAMUR Mount Hygienic Valve
NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in
More informationCheck Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits
Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot
More informationHigh Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override
Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for
More informationzamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool
P0 0mm COMPCT valves - threaded body and for sub-base mounting - Low standard power consumption (0,W): low power consumption electropilot B0 (standard version with LED) - Quick response times - High flow
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationProportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More informationindirect electro-pneumatic, pneumatic, manual, mechanical pneumatic spring, mechanical spring G1/8 6,5 890
L-M UNVRSL istributors / - / - UNVRSL Modular System: possibility to create a lot of different valves with a short number of basis elements - ontrol: manual, mechanical,, electric - Traditional UNVR spool
More informationRated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1
200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing
More information5 Port Solenoid Valve
Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size
More informationQ Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications
Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Technical Catalog PVQ10 PVQ13 PVQ20 PVQ25 PVQ32 PVQ40 PVQ45 Table of Contents Introduction......................................................................................................
More informationOCTOPUS SELECTION & INSTALLATION GUIDE
OCTOPUS SELECTION & INSTALLATION GUIDE 38mm BORE LINEAR ACTUATOR STYLES LAM & LAR A. GENERAL DESCRIPTION: The Octopus hydraulic linear actuator is a simple, efficient and reliable way of driving the rudder
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More informationLINEAR MOTION CONTROL
LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More information4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
More informationOn-off valves MS-EM/EE, MS series, NPT
On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12
More informationCatalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...
More informationApplication Feature Valve Nominal Liquid Capacity R-22 (in tons)*
EMERSON CLIMATE TECHNOLOGIES-Solenoid Valves & Coils Quick Select Guide Applications Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* Nominal Liquid Capacity R-410A (in tons)* Liquid Line
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationPiston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
More informationWELCOME TO MAGNATROL
Catalog 6 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More informationVickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More informationSolenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.
Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 50 bar (5000 psi) and 7 L/min (60 USgpm) n Eaton rand ETON Screw-In Cartridge Valves E-VLSC-MC00-E November 009 -.
More informationManapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM
Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationNorbro Series 40R Pneumatic Actuator Double Acting or Spring Return
Pneumatic Actuator Double Acting or Spring Return Since the mid-sixties the Norbro name has been recognised as the leading quarter turn actuator for industry. As proof of this, Norbro pneumatic actuators
More informationOEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
More informationFlow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle
More informationProximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
More information