1 Catalog 6

2 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936 Experienced Dedicated Sales Staff Application / Engineering Assistance Excellent Product Support Quick Delivery Our continued success has come from manufacturing a top quality product, product support, commitment to service and on-time delivery assuring complete customer satisfaction. Our Products Every valve is manufactured and tested in-house following Quality Assurance Standards where production operations are under the control of our dedicated, experienced staff and workforce. TABLE OF CONTENTS Category Pages(s) Coils Construction Features Bronze Valves N & NR & A & AR & 9 M & MR & S & SR & 13 L & LR & 15 G & GR & 1 D Strainers Stainless Steel Valves J & JR & 21 K & KR & W & WR & Optional Features & 2 Special Valves Universal Mount P Sandy Well Water Gritty Coolant & 31 Ordering Information & Terms & Conditions/Contact Info * Custom Engineered Valves, Special Alloys, Temperatures, Pressures and Applications as well as Modifications to Standard Magnatrol Valves are available through Magnatrol s Clark-Cooper Division. (See bottom of page 3) High Quality Bronze and Stainless Steel Solenoid Valves* Pressures up to 0 * Temperatures up to 0 F * Cryogenic and Oxygen Service Applications Normally Closed (Energize to Open) Normally Open (Energize to Close) Continuous Duty Coils for all & Voltages NO Differential Pressure Required to Open Full Port-Internal Pilot Operated or Direct Acting 2-Way Straight Thru Design Packless Construction 2 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

3 BULLETIN 6-VALVE SELECTION CHART VALVE SELECTION CHART Ordering Information - See Pages 32 & For Optional Features - See Pages 26 & 2 VALVE SELECTION CHART (For Fluids/Gases Not Listed And For Special Applications, Consult Factory) Max. Temperature Up To 212 F Up To 0 F Construction Bronze Stainless Steel Valve Type D G/GR N/NR A/AR M/MR S/SR L/LR K/KR W/WR Page 16 & 1 6 & & 9 & 12 & & & & Max. Pressure / /4-3 3/ -3/ Internal Port Full Full Reduced Full Reduced Full Full Full Full Air Brine Gas Oil Solvents Water Vacuum Steam Cryogenic Oxygen, Liquid Oxygen, Gaseous Corrosive Use the chart above to determine suitable types of Magnatrol valves for a given application. Example: A normally closed valve for use on 0 psi steam, there are three types suitable and the final selection can only be made after referring to Bulletins 6-M, 6-S and 6-W on pages, 12 and 22 respectively. Maximum Differential Pressure: When specifying a valve, the Maximum Differential Pressure must be equal to or greater than the application. Care should be taken not to over specify the valve by choosing a valve with a Maximum Differential Pressure that is excessively beyond the application. If you are unsure please consult the factory. 2-Way and 3-Way 1/4 Thru 6 Pressures to,000 s up to 5 F Dirty / Viscous & Corrosive Fluids Bronze, 316SS, Monel, Alloy 20 & Hastelloy 3-Valve Manifold for CNG Refueling End connections: NPT, Flange, Union, Socket Weld, Butt Weld, Nipples etc. Options: Remote Trip with Manual or Automatic Reset and many others High Pressure Cartridge Valve,000 3-Way Trip Valve with 2 Position Indicating Switches and Manual Reset Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 3

4 BULLETIN 6-COIL SOLENOID COILS CONTINUOUS DUTY COILS ELECTRICAL CHARTERISTICS Coils are stocked for the following voltages: Voltage , Hertz * * 5V for locomotive applications * Furnished with surge protecting capacitor Reference should be made to the Bulletins to determine the availability of a required valve for a specific power supply. Consult the factory for information regarding voltage and frequencies not listed. ENCAPSULATED COIL Valves for A.C. service can be converted for use on other A.C. voltages simply by changing the coil. Similarly D.C. valves can be converted for other D.C. voltages. Consult factory regarding conversion from A.C. to D.C. or D.C. to A.C. CURRENT CONSUMPTION: Current values shown in the bulletins are for 120 volts, hertz. For other voltages the current is inversely proportional: For instance, if a given valve draws 0.5 amperes on 120 volts it would draw 0. amperes on 2 volts, or 0.1 amperes on volts. Where power consumption is shown in D.C. watts, the values given should be divided by line voltage to obtain the current in amperes. Power consumption for all valves is shown in the individual bulletins. CONSTRUCTION: Continuous Duty Construction: Coils can be energized continuously without overheating or failure. Wire Leads: long gauge wire standard (longer continuous leads available) Encapsulated: Coils are encapsulated for temperature of intended service, providing excellent resistance to shock, moisture, oil and chemicals COIL CLASS: GENERAL SERVICE - CLASS B HIGH TEMPERATURE - CLASS H Maximum Fluid Maximum Ambient Maximum Fluid Maximum Ambient Temperature Temperature Temperature Temperature 212 F ( C) 04 F ( C) 00 F (206 C) 12 F (0 C) INSTALLATION: The coil is a two wire device which may be controlled by either a single or double pole switch. The switch should always be installed in the hot leg of 120 volt circuits. Where both legs are hot, such as 2 or volt circuits, a double pole switch is preferable, however, if a single pole switch is used, then the wiring should have top quality insulation since even minute leakage currents may give rise to sticking problems. On motor hookup with step control starter, full voltage should be supplied to coil immediately. Note: Coil can be readily changed while valve is still under pressure. 4 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

5 BULLETIN 6-CONSTRUCTION VALVE CONSTRUCTION FEATURES Valve Construction Features: 2-way straight thru globe design Bronze or Stainless Steel body w/ female NPT threads standard Stainless Steel available with 1# and # flanged ends Full port-internal pilot operated or direct acting Packless construction Continous duty coils for all voltages No differential pressure required to open Easy In-Line Service Inspect, clean or service all internal parts of full port-internal pilot operated or direct acting while the valve body remains in the pipeline shortening costly down time and increasing productivity. HOUSING Construction: Malleable or Cast Iron Designed for rugged industrial use Self contained terminal box with NPS conduit connection COIL Available Class B or H insulation Designed for continuous duty service Available in most or voltages Coil Enclosure Available: NEMA 12, 4, 4X and Explosion Proof Conduit Boss Coil BONNET PISTON ASSEMBLY A sturdily constucted stem assembly consisting of a plunger and stainless steel pilot flexibly connected to the piston Discs are available in various materials dictated by operating conditions A flanged metallic tube encloses the plunger and hermetically seals the top of the valve VALVE BODY Constructed of high pressure cast bronze or stainless steel in a globe pattern with screwed ends* Bonnet Piston Valve Disc Disc Nut Bonnet Ring Plunger Valve Spring Pilot Valve Valve Body Normally Closed Valve shown is typical of Type A, thru 1-1/4 Available in a full range of sizes * Stainless Steel valves available with flanged ends. Flanged Bronze valves available through Magnatrol s Clark-Cooper Division (See bottom of MAGNATROL SOLENOID OPERATED VALVES are used to control the flow of liquids or gases, generally in conjunction with automatic control apparatus such as thermostat, float switch, time switch, or flow meter. Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 5

6 BULLETIN 6-N BRONZE SOLENOID VALVES 212 F FOR OPTIONS & CESSORIES TYPE N - NORMALLY CLOSED TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 3/32 TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem Stainless Steel *Spring Stainless Steel *Body Seal - Buna N *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ Max. Valve Port Hold Inrush DISCONTINUED -- USE VALVE WITH BUSHING A Dimensions In B C D 3/4 3/ N22 1/4 N42 5 3/16 N /4 5-3/ 2-3/4 2-3/4 0 5/32 N2 1 1/ N62 2 3/32 N2 3/ N22 5 5/16 N32 0 1/4 N / 6-3/ 2-3/4 1 3/16 N52 1/ N62 15 N13 5/16 N / 2-3/4 2-/ 30 N / 6-2-/ 5 5/16 N Voltage ( or ) Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids 6 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

7 BULLETIN 6-NR BRONZE SOLENOID VALVES TYPE NR - NORMALLY OPEN TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 3/32 TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Buna N *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 212 F FOR OPTIONS & CESSORIES 3/ Max. Valve Port Hold Inrush DISCONTINUED -- USE VALVE WITH BUSHING A Dimensions In B C D Voltage ( or ) 3/4 3/ NR22 1/4 NR42 0 3/16 NR /32 NR / 2-3/4 2-3/4 1 1/ NR62 3/32 NR2 3/ NR22 0 5/16 NR /4 NR / -1/ 2-3/4 1 3/16 NR / NR62 13 NR /16 NR /4 6-3/ 2-3/4 2-/ 2 NR13 0 5/16 NR / -1/4 2-/ Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

8 BULLETIN 6-A BRONZE SOLENOID VALVES 212 F Except valves listed for 0 TYPE A FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) Vacuum materials and free of sediment. Valve operates from zero to maximum horizontal pipe with solenoid enclosure vertical and on top. 3/ / Max Dimension In Hold Inrush A B C D 1 A42 A32 A / 2-3/4 3-1/4 0 EA / 4-1/ 3-1/4 1 A A A / 6 2-3/4 A53 A / 0 E1A / 4-1/ 1 A24 A A / 6-5/ 2-3/4 4-1/ A54 A / - 4-1/ 4-1/ 0 E1A / - 4-1/ 4-1/ 90 A A A / 6-3/4 2-3/4 4- A A / -3/4 4-0 A / -3/ A46 1A46 4. A / 4 4-/ 41A36 41A A / 4-4-/ 0 36A2 36A A /4 5-3/ 6 42A3 42A /4 5-3/ A A2 1 43A4 43A / -1/ 5-/ -1/4 143A A29 44A49 44A /4-6-5/ -3/ 144A D(Flanged) 1# 4-3/ /4 9- FOR OPTIONS & CESSORIES Voltage ( or ) Not available for operation Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

9 BULLETIN 6-AR BRONZE SOLENOID VALVES TYPE AR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CESSORIES Voltage ( or ) Not available for operation 3/ / Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey F Except valves listed for 0 Max Dimension In Hold Inrush A B C D 1 AR42 AR32 AR / 2-3/4 3-1/4 0 EAR / -1/4 4-1/ 3-1/4 1 AR AR /4-1/ 2-3/4 AR AR /4-1/ 0 E1AR / 4-1/ 1 AR24 AR /4 2-3/4 4-1/ AR34 AR / 4-1/ 0 E1AR /4 -/ 4-1/ 4-1/ 90 AR AR /4-1/ 2-3/4 4- AR AR /4 9-1/ 4-0 AR / AR26 AR / / 41AR AR56-5/ 9-3/4 4-4-/ 0 141AR AR2 36AR / -1/ 5-3/ 6 42AR3 42AR AR / -3/ 5-3/4 6 43AR2 1 43AR AR / -1/4 44AR29 143AR AR AR / -1/ 6-5/ -3/ 144AR D(Flanged) 1# 4-3/ /4 9-9

10 BULLETIN 6-M BRONZE SOLENOID VALVES 0 F 1 FOR OPTIONS & CESSORIES TYPE M - NORMALLY CLOSED 3/ TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. INLET 3/ 3/4 Max. Valve Port **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. Hold Inrush 3/ M21 1/4 M41 5 3/16 M /4 5-2-/ 2-5/ 0 5/32 M1 1 1/ M61 3/ M /16 1/4 M31 M / 6-3/ 2-5/ 1 3/16 M51 3/ M22 1/4 M42 5 3/16 M /4 5-2-/ 2-3/4 0 5/32 M2 1 1/ M62 3/ M /16 1/4 M32 M / 6-3/ 2-3/4 1 3/16 M /16 M13 M / 2-/ 2-/ /16 M13 M / 6-2-/ A Dimensions In B C D Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids Voltage ( or ) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

11 BULLETIN 6-MR BRONZE SOLENOID VALVES TYPE MR - NORMALLY OPEN 3/ TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. * Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads Voltage ( or ) (See pages 26& 2) 3/ 3/4 Max. To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 0 F 1 FOR OPTIONS & CESSORIES **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. Valve Port Hold Inrush 3/ MR21 1/4 MR41 0 3/16 MR /4 2-/ 2-5/ 90 5/32 MR1 1 1/ MR61 3/ MR /16 1/4 MR31 MR / -1/ 2-5/ 1 3/16 MR51 3/ MR22 1/4 MR42 0 3/16 MR /4 2-/ 2-3/4 90 5/32 MR2 1 1/ MR62 3/ MR /16 1/4 MR32 MR / -1/ 2-3/4 1 3/16 MR /16 MR13 MR /4 6-3/ 2-/ 2-/ 2 0 5/16 MR13 MR / -1/4 2-/ Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 A Dimensions In B C D

12 BULLETIN 6-S BRONZE SOLENOID VALVES 0 F TYPE S FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES Max / / S22 4S42 129S42 14S 4S43 129S43 16S14 6S24 6S44 131S44 1S15 S 132S 1S S16 S26 1S46 141S46 36S1 36S2 42S4 142S4 43S 43S2 43S4 143S4 44S19 44S29 44S49 144S Hold TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Inrush Dimension In A B C D UL Listed Valves - Consult Factory Not available for operation / -1/ -/ -3/ 9-3/ -3/ / 13-3/4 5-/ 6-/ 6 6-5/ - 6-3/4-3/4-3/4-1/ 9-1/ -3/4 9-3/4-1/ - 2-/ 2-/ 3-1/4 3-5/ / 5-3/ 5-/ 6-5/ 3-1/4 3-1/ / / 4-/ 6 6-1/4-3/ D(Flanged) 1# 4-3/ /4 9- Voltage ( or ) 12 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

13 BULLETIN 6-SR BRONZE SOLENOID VALVES TYPE SR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Springs - Inconel and 302 Stainless Steel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Voltage ( or ) Max / / SR22 4SR42 129SR42 14SR 4SR43 129SR43 16SR14 6SR24 6SR44 131SR44 1SR15 SR 132SR 1SR SR16 SR26 1SR46 141SR46 36SR1 36SR2 42SR4 142SR4 43SR 43SR2 43SR4 143SR4 44SR19 44SR29 44SR49 144SR Hold Inrush UL Listed Valves - Consult Factory Not available for operation 0 F FOR OPTIONS & CESSORIES Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey Dimension In A B C D -1/ 9-1/ -1/ 9-1/4 9-1/ 9-3/4-3/4-3/ -5/ 12-3/ 12-5/ 6-1/ -3/4-5/ -1/ 9-1/ 9-3/ 9-9-3/4-1/ -3/ 2-/ 2-/ 3-1/4 3-5/ / 5-3/ 3-1/4 3-1/4 4-1/ 4-1/ / 4-/ 1-3/4 5-/ -1/4 6 6 D(Flanged) 1# 4-3/ / / -1/ 6-5/ -3/ 9-

14 BULLETIN 6-L BRONZE SOLENOID VALVES 0 F Except valves listed for 0 TYPE L FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES FOR STEAM APPLICATIONS SEE BULLETIN 6-S Page 12 To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ / Max L42 14L32 29L52 E29L62 14L 14L43 29L 129L53 Hold Inrush Dimension In D(Flanged) A B C D 1# 5-/ 2-/ 3-1/4 4-3/4 6-/ 3-1/4 6-/ 4 3-1/4-1/ 6 2-/ 5- -1/ E129L / 4 16L L / 3-1/4 4-1/ 31L L / - 4-1/ 0 E131L / / 90 1L 1L / 6-3/4 4-32L L / -3/4 3-5/ 4-0 1L / -3/ L26 L46 41L36 141L / 9-1/ / 4-/ 0 141L L2 36L4 42L3 42L L L2 43L4.0 43L L L L49 44L39 144L Not available for operation /4 9-3/4 5-3/ 5-3/ / -1/ 5-/ -1/ /4-6-5/ -3/ /4 9- ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 14 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

15 BULLETIN 6-LR BRONZE SOLENOID VALVES TYPE LR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seal it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. 0 F Except valves listed for 0 ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ / CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Springs - Inconel and 302 Stainless Steel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES FOR STEAM APPLICATIONS SEE BULLETIN 6-SR Page 13 To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Max LR42 14LR32 29LR52 E29LR62 14LR 14LR43 29LR 129LR53 Hold Inrush Dimension In A B C D -1/ 9-1/ 9-1/ -1/4-1/ 2-/ 4 2-/ 3-1/4 3-1/4 3-1/ /4-1/ 0 E129LR /4-1/ LR24 16LR / -3/4 3-1/4 4-1/ 31LR LR / 4-1/ 0 E131LR / 4 4-1/ 90 1LR 1LR /4-1/ 4-32LR 132LR /4 9-1/ 3-5/ 4-0 1LR LR26 5 LR46 41LR36 141LR LR LR2 36LR4 42LR3 42LR / / 9-3/ 4 4-/ / 9-3/4 4-4-/ LR LR2 1 43LR LR3 143LR LR LR LR39 144LR Not available for operation / 12-5/ -1/ -3/ 5-3/ 5-3/ 1-3/4 5-/ -1/ / -1/ 6-5/ -3/ 6 6 D(Flanged) 1# 4-3/ /4 9- Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 15

16 BULLETIN 6-G BRONZE SOLENOID VALVES 212 F 1 TYPE G FULL PORT - NORMALLY CLOSED 1 TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. FOR OPTIONS & CESSORIES 1 1-1/ Max G24 1G24 1G24 G 1G 1G G26 1G26 1G26 G2 1G2 3G2 43G2 143G2 44G29 144G UL Listed Valves - Consult Factory CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem Stainless Steel *Pilot Valve Disc Holder - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Hold Inrush Dimension In A B C D / -1/ -1/ 9-1/ 9-/ 9-/ 9-/ 12-1/ 12-1/ / 6-1/ -1/ 6-3/ 6-3/ -3/ / -/ -/ -5/ 9-5/ 2-3/4 2-3/4 2-/ 2-/ 3-1/ 3-1/ 3-3/4 3-3/4 3-3/4 5-/ 5-/ 6-5/ 6-5/ 4-1/ 4-1/ 4-1/ 4-3/ 4-3/ 4-3/ 4-3/4 4-3/4 4-3/4 5-3/4 5-3/4 5-3/4 -/ -/ D(Flanged) 1# 6-3/4-3/4 13-5/16 Voltage ( or ) 16 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

17 BULLETIN 6-GR BRONZE SOLENOID VALVES TYPE GR FULL PORT - NORMALLY OPEN 1 TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. 212 F 1 CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem Stainless Steel *Pilot Valve Disc Holder - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CESSORIES Voltage ( or ) 1 1-1/ Max GR24 GR24 GR GR GR26 GR26 GR2 1GR2 43GR2 44GR29 Hold Inrush Dimension In A B C D -5/ 9-5/ 9-3/ -1/ /4-1/4 12-3/4 13-5/ -1/4-1/4-3/4-3/4 -/ -/ 9-1/4 9-1/4-1/4-5/ 2-3/4 2-3/4 2-/ 3-1/ 3-3/4 3-3/4 5-/ 6-5/ 4-1/ 4-1/ 4-3/ 4-3/ 4-3/4 4-3/4 5-3/4 5-3/4 -/ D(Flanged) 1# 6-3/4-3/4 13-5/16 UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 1

18 BULLETIN 6-D BRONZE SOLENOID VALVES 212 F 1 TYPE D FULL PORT - NORMALLY CLOSED 3/ TO 2 PIPE SIZE Valve opens when energized and closes when de-energized. In this direct acting valve the disc holder assembly is lifted from its seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Disc Holder - Brass Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. n. *Stem Stainless Steel *Spring Stainless Steel *Body Seal - Buna N *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) FOR OPTIONS & CESSORIES To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the main orifice make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ 3/ /4 1-2 Max D D D12 D12 D13 D13 D14 D14 D15 D15 D16 D16 D1 1D1 Hold Inrush Dimension In A B C D 6-1/4-1/ 6-1/4-1/4 6-/ -3/ / -1/ 9-1/ 9-/ 9-/ 5-3/ 6-3/ 5-6-3/ 5-3/4 6-3/4 6-1/ -1/ 6-3/ -3/ / -/ 2-3/4 2-3/4 2-3/4 2-3/4 2-/ 3-1/ 3-3/4 3-3/4 D(Flanged) 1# 2-/ 2-/ 3-1/ 3-1/ 4-3/ / 4-1/ 6-3/4 4-3/ 4-3/ 4-3/4 4-3/4-3/4 5-3/4 5-3/4 Voltage ( or ) UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

19 BULLETIN 6-STN-Y STRAINERS Bronze Stainless Steel The presence of foreign particles in an automatic valve may seriously affect its dependability. The installation of a strainer close to the inlet side of the valve is the best means of preventing the entrance of pipe chips, scale, rust, pipe dope, welding slag or sediment into the valve, provided the screen is periodically removed for cleaning. CONSTRUCTION: Strainer bodies have screwed ends. Screens are stainless steel with opening sizes as listed in tables below. Other sizes can be furnished upon request. Liberal straining area provides for fluid passage at minimum pressure drop. Screens are easily removed for cleaning. furnished with NPT blow-off connections unplugged. See charts below for blow-off sizes (C Dim.) CLEANING FOR CRYOGENIC & OXYGEN SERVICE: Strainers for Cryogenic applications are degreased and cleaned to keep them free of moisture. Strainers for Oxygen service are degreased and cleaned then black light tested. BRONZE 1/4 TO 3 PIPE SIZE Screen Dimensions In 1/4 BR 0 3/4 2-3/4 2-1/4 1/4 3/ Mesh BR 1 3/4 2-3/4 2-1/4 1/ BR 2 3/4 2-3/4 2-1/4 1/4 3/4 Openings BR /16 3/ 1 BR 4 2-1/4 3-3/4 2-3/4 3/ 1-1/4 BR 5 3-1/4 4-/16 3-5/ 3/ Diameter BR /16 3-/ 3/4 2 Perforations BR 6-1/ 5-1/16 1 Lined With 2-30 Mesh BR / /4 3 BR /4 1- A B C STAINLESS STEEL TO 2 PIPE SIZE Screen Dimensions In Mesh SS / 1/4 3/ SS 3 2-1/4 3-3/4 2-13/16 3/ 1 Openings SS 4 3-1/4 4-5/ 3-1/ 3/ Diameter SS 6 6-3/4 5-5/ 4-3/4 3/4 Perforations 2 Lined w/30 Mesh SS A B C PRESSURE TEMPERATURE RATINGS MATERIAL STEAM LIQUIDS 0 F 0 F STAINLESS F 0 F Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 19

20 BULLETIN 6-J STAINLESS STEEL SOLENOID VALVES 0 F TYPE J - NORMALLY CLOSED 3/ TO PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO 3/ Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (*Wetted parts) *Valve Body Stainless Steel Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPT conduit conn. *Valve Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS AND CESSORIES 3/ Max. Valve Port 3/ J21 5 3/16 J51 1 1/ J61 3/ J21 1 3/16 J51 1/ J61 3/ J22 5 3/16 J52 1 1/ J62 3/ J22 1 3/16 J52 1/ J62 To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics and any other fluids not reactive with construction materials and free of sidement. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon(-303ºf) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Hold Inrush A Dimensions In /4 5-2-/ 2-3/ / 6-3/ 2-3/ /4 5-2-/ 2-3/ / 6-3/ 2-3/4 Optional Soft Seat Orifice Seal: (for applications requiring tight seating): Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids B C D ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 20 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

21 BULLETIN 6-JR STAINLESS STEEL SOLENOID VALVES TYPE JR - NORMALLY OPEN 3/ TO PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO 3/ Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. 0 F ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ CONSTRUCTION: (*Wetted parts) *Valve Body Stainless Steel Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPT conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics and any other fluids not reactive with construction materials and free of sidement. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Max. Valve Port 3/ JR21 0 3/16 JR51 1 1/ JR61 3/ JR21 1 3/16 JR51 1/ JR61 3/ JR22 0 3/16 JR52 1 1/ JR62 3/ JR22 1 3/16 JR52 1/ JR62 Hold Inrush A FOR OPTIONS AND CESSORIES Dimensions In /4 2-/ 2-3/ / -1/ 2-3/ /4 2-/ 2-3/ / -1/ 2-3/4 Optional Soft Seat Orifice Seal: (for applications requiring tight seating): Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids B C D Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 21

22 22 0 F Except valves listed for 0 FOR OPTIONS & CESSORIES 3/ Max. 1 14K42 14K32 BULLETIN 6-K STAINLESS STEEL SOLENOID VALVES TYPE K FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. Hold Inrush CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY A Dimensions In FOR STEAM APPLICATIONS SEE BULLETIN 6-W Page 22 Voltage ( or ) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 B C D NPT D (Flanged) 1# # / 2-/ 0 29K52 E29K / 4 3-1/ K / 6 2-/ K / 0 E129K K K / 3-1/4 31K / / K54 E131K K / 4 41K / K / K K /4 42K3 42K /4 5-3/ K K49F K39F1 13-3/4-6-5/ 144K59F ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested.

23 BULLETIN 6-KR STAINLESS STEEL SOLENOID VALVES TYPE KR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ FOR STEAM APPLICATIONS SEE BULLETIN 6-WR Page 0 F Except valves listed for 0 FOR OPTIONS & CESSORIES Max. Dimensions In Hold Inrush D (Flanged) A B C D 1# # 1 14KR42 14KR / 2-/ 29KR / 0 E29KR / KR /4-1/ 2-/ 29KR KR /4-1/ 0 E129KR KR / -3/4 3-1/4 31KR / KR / 0 E131KR KR / KR / KR / 9-3/ KR KR / -1/ 42KR3 42KR / -3/ 5-3/ KR KR49F1 44KR39F / -1/ 6-5/ 9-144KR59F ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

24 BULLETIN 6-W STAINLESS STEEL SOLENOID VALVES 0 F TYPE W FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. 3/ FOR OPTIONS & CESSORIES Max. Hold Inrush CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top W22 4W / 2-/ 3-1/ W / 1 14W 4W / 6 2-/ W / 16W W24 6W / 3-1/ W / - W16 W / W W / 4-36W1 36W / W4 142W /4 44W19F1 44W29F W49F W49F A Dimensions In B C D D (Flanged) 1# 4-1/ 6-4-/ 6-5-3/ /4-6-5/ 9- ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY Voltage ( or ) 24 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

25 BULLETIN 6-WR STAINLESS STEEL SOLENOID VALVES TYPE WR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads 0 F To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Voltage ( or ) 3/ Max. Hold Inrush FOR OPTIONS & CESSORIES WR22 4WR / 2-/ 3-1/ WR / 1 14WR 4WR /4-1/ 2-/ WR /4-1/ 16WR WR24 6WR / -3/4 3-1/ WR / WR16 WR / WR WR / 9-3/4 4-36WR1 36WR / -1/ WR4 142WR / -3/ 44WR19F1 44WR29F WR49F WR49F / 6-4-/ 6-5-3/ / -1/ 6-5/ 9- Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 A Dimensions In B C D D (Flanged) 1# ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY

26 BULLETIN 6-OPT OPTIONAL FEATURES For Solenoid Valves See Individual Options For Availability For Use With Specific Valve Types BOTTOM MOUNTED OPTIONS Note: Only One Bottom Mount Option Can Be Installed On Each Valve MANUAL OVERRIDE (Normally Closed valves only) (Designated by Prefix MO ) Enables manual opening of solenoid valve during power failure or to override automatic controls. DASHPOT (Designated by Prefix DP ) Furnished for clean liquids to reduce water hammer effect sometimes encountered in long pipe runs by slowing valve closing. LEVER (Normally Closed valves only) (Designated by Prefix LV ) Enables rapid opening of solenoid valve. Can be chain operated for use at inaccessible locations. FLOW CONTROL (Normally Closed, NR & MR valves, only) (Designated by Prefix FC ) Provides a manual method of reducing or throttling the flow. MOUNTING STUD (Designated by Prefix MS ) 3/ -16 thread can be furnished in bottom of body to facilitate mounting on bracket. (Not available on 2, 2- and 3 ) DRAIN (Normally Closed, NR & MR valves, only) (Designated by Prefix DR ) - 1/4 NPT plug supplied in bottom of valve to facilitate draining of liquid OTHER OPTIONS PILOT TAP (Designated by Prefix PT ) Type D, G & GR Valves can be furnished with 1/ tapped hole for pilot connection or pressure gauge. DIN CONNECTOR (Designated by Suffix DN ) Provides 3 prong connector for easy power connect / disconnect. Not available for Explosion-Proof. 26 HUM FREE : (No Hum/Buzz) (Designated by Suffix HF ) - The HUM FREE option eliminates the hum associated with operated solenoid valves. Enables valves to be used where an hum would not be acceptable and is the only power source available. IE: Hospitals, labs, schools (class rooms), homes, office environments etc. & when 24 vac is required for series valves. Leak / Dead Tight: (Normally Closed valves only) (Designated by Suffix LT ) - The Leak / Dead Tight Option offers soft resilient seating or gapless seal for low pressure applications or less. Consult Factory for Max. Pressure and Valve Type availability. Flanged Ends for Bronze and Stainless Steel Valves: (Designated by Suffix F1 for 1 lb or F3 for lb Flanges) F1 or F3 Flanged ends available on all stainless steel valves. F1 Flanged ends available on bronze valves. F3 Flanged ends for bronze valves available through our Clark-Cooper Division. Explosion-Proof and Watertight Solenoids: (Designated by Prefix F ) are Explosion-proof and NEMA 4, C & D, 9E, F & G suitable for use in hazardous locations requiring Class I, Groups C & D & Class II Groups E, F, and G equipment. NEMA 4X: (Designated by Prefix F AND Suffix ZP ) are suitable for use in locations requiring a NEMA 4X designation. ZP (Zinc Plating) replaces the standard paint used on the Coil housing (cup and base). The additional corrosion protection satisfies NEMA 4X requirements. Internal construction, pressure ratings, power consumption, and external dimensions are the same as for standard valves. Nickel Plating: (Designated by Suffix NP ) - Plating is Thick Meets Mil Spec. C24 Universal Mount Valves For Mounting In Vertical Runs (See Magnatrol Universal Mount Catalog 6-UM) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years

Solenoid and Air Operated Valves. Supporting Fleet Operations for Over 60 Years 4 Solenoid and Air Operated Valves Supporting Fleet Operations for Over 60 Years This catalog describes solenoid and air operated valves, representative of those manufactured by ASCO Valve, Inc. to meet

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

B-Series Switches Pressure, Differential Pressure & Hydraulic

B-Series Switches Pressure, Differential Pressure & Hydraulic FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide: LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid 2- and 3-way Solenoid Valves for Gas and Liquid SV10: Vacuum to 3000 psig SV430: Vacuum to 3000 psig SV20: Vacuum to 6000 psig SV460: Vacuum to 6000 psig SV30: Vacuum to 3000 psig Circle Seal Controls

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them

More information

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

PLUMBING RE-SUBMITTAL 22 11 17

PLUMBING RE-SUBMITTAL 22 11 17 PLUMBING RE-SUBMITTAL 22 11 17 ACADEMIC BUILDING & PATRIOT S CASA TEXAS A&M UNIVERSITY - SAN ANTONIO, TX NO. 25-3122, VAC NO. 39019 OWNER: ARCHITECT: MEP ENGINEER: GENERAL CONTRACTOR: PLUMBING CONTRACTOR:

More information

The First Line of Safety

The First Line of Safety Pilot Operated Pressure Relief Valves The First Line of Safety Pilot Operated Pressure Relief Valves 597C Farris Engineering Pressure Relief Valves Process Pressure Relief Valves Series 2600 ASME NB Certified:

More information

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper www.quilinox.

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper www.quilinox. valve solutions www.quilinox.com Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper valvulas esfera PBM.pdf (1753) 2015/01 1/10 D E SIGN F E A

More information

Coil Classification: Class F standard, Class H available Class B standard on V9xx models

Coil Classification: Class F standard, Class H available Class B standard on V9xx models Direct Acting & Pilot Operated Valves 1/8" - 1/2" General Description: Direct Acting and Pilot Operated valves are used in applications for actuation of double acting cylinders and piloting of larger control

More information

Precision Solenoid Valves

Precision Solenoid Valves Precision Solenoid Valves Solenoid Valves for gas General Purpose Valves Specialty Solenoid Valves n Didn t see what you re looking for? Let us review your requirements and chances are we can help solve

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

IOM SERIES 820-E/P Electro-Pneumatic Positioner

IOM SERIES 820-E/P Electro-Pneumatic Positioner FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE

More information

AUTOMATIC CHANGEOVER MANIFOLD Series 915

AUTOMATIC CHANGEOVER MANIFOLD Series 915 AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY CHEXTER TM FITS YOUR APPLICATION, PROFITABLY Commercial Construction CHEXTER TM Check Valves are economically used in chilled and hot water air conditioning systems, refrigeration and other piping and

More information

Check Valves & Actuated Valves

Check Valves & Actuated Valves heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors

Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors TABLE OF CONTENTS 389 We stock more than 2,000 different ASCO solenoid valves, repair kits, and replacement coils. What we don t stock, we can usually get from the factory within 5 working days! As the

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

WD600 STEAM TRAPS. Thermodynamic Steam Trap

WD600 STEAM TRAPS. Thermodynamic Steam Trap WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007 Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE

More information

4 Nuclear Catalog. Nuclear Products Qualified to IEEE Specifications. Solenoid Valves. Check Valves. Pressure & Temperature Switches

4 Nuclear Catalog. Nuclear Products Qualified to IEEE Specifications. Solenoid Valves. Check Valves. Pressure & Temperature Switches 4 Nuclear Catalog Nuclear Products Qualified to IEEE Specifications Solenoid Valves Check Valves Pressure & Temperature Switches Hydramotor Actuators www.ascovalve.com Index Engineering Information 2-8

More information

KF Needle & Gauge Valves

KF Needle & Gauge Valves KF Needle & Gauge Valves Superior Fluid Control Products KF O-Ring & Packed Stem Style Needle Valves KF Needle Valves combine rugged construction, dependability and leak-free performance at high and low

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size CRANE Σελίδα από 2 DM93 Variable Orifice Double Regulating Valve PN6 Cast Iron Balancing Valve (VODRV), Flanged to BSEN 92-2 The DM93 variable orifice double regulating valves will give satisfactory performance

More information

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203)

More information

needle valves Needle Valves Index At a Glance 1

needle valves Needle Valves Index At a Glance 1 Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Type 3353 Angle Seat Valve

Type 3353 Angle Seat Valve Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Mono-Block II Installation & Operation Manual

Mono-Block II Installation & Operation Manual Mono-Block II Installation & Operation Manual Enraf Fluid Technology UK, Ltd. Enraf Fluid Technology USA, Inc. 6 Pennant Park, Standard Way 2000 Northfield Court Fareham, Hampshire, England PO16 8XU Roswell,

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features High Pressure, Surge Anticipating Control Valve Eliminates surge in all pumping systems: Booster & deep well, single & variable speed Eliminates surge in all distribution networks: Municipal, high-rise

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1 INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES

WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES WH/WIH/WIHD/WIHD&M/WIHL AND WIH 17-67 SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

PBM has solutions for your valve application.

PBM has solutions for your valve application. valve solutions i n d u s t r i a l v a l v e s Whether the application is in a chemical plant, paper mill, food plant, manufacturing environment, or other industrial setting, PBM S line of Industrial

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

Model DE-3 Air Release Head

Model DE-3 Air Release Head SPECIFICATIONS MEASUREMENT SOLUTIONS Model Air Release Head Bulletin SS03037 Issue/Rev. 0.2 (10/15) We put you first. And keep you ahead. SMITH METER AIR ELIMINATOR The Smith Meter Model Air Release Heads

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information