Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Size: px
Start display at page:

Download "Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US"

Transcription

1 Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C Needle Valve, Cartridge Type...45/ / NVH81... C Needle Valve, Cartridge Type...38/ / NVH11... C Needle Valve, Cartridge Type...6/ / J6A2... C Needle Valve, Cartridge Type...225/ / J2B2... C Needle Valve with Reverse,... 2 to 1 Free...3/ / FV11... C Needle Valve with Reverse,... 1 to 2 Free...45/ / FV12... C Needle Valve with Reverse,... 1 to 2 Free...23/ / PRESSURE COMPENSATED FLOW CONTROLS J2E2... C Restrictive Control, Adjustable...2/ / FR11... C Restrictive Control, Tuneable...26/ / J4E2... C Restrictive Control, Adjustable...4/ / J4C2... C Restrictive Control, Adjustable...4/ / FA11... C Restrictive Control,... Reverse, Adjustable...21/ / C Restrictive Control,... Reverse, Tuneable...56/ / PRESSURE COMPENSATED PRIORITY FLOW CONTROLS J2D3... C Priority Type, with Bypass...15/ / FP11... C Priority Type, with Bypass...56/ / J4D3... C Priority Type, with Bypass...45/ / J1A A... Priority Type, with Bypass...9/ / PRESSURE COMPENSATORS R11... C Restrictive Type, Press. Compensators...38/ / R C Restrictive Type, Press. Compensators...15/ / Note: Also see R4C3 on page 1. PRIORITY PRESSURE COMPENSATORS P11... C Priority Type, with Bypass...56/ / PH C Priority Type, with Bypass...95/ / FLOW DIVIDERS/COMBINERS F11... C Divider/Combiner...45/ / L4A3... C Divider/Combiner...6/ / L6A3... C Divider/Combiner...18/ / L1A Divider/Combiner...32/ / Denotes New Winner s Circle Product Line.

2 Catalog HY15-352/US Tips Control INTRODUCTION This technical tips section is designed to help familiarize you with the Parker line of Control. In this section we present common options available as well as a brief synopsis of the operation and applications of the various product offered in this section. The intent of this section is to help you in selecting the best products for your application. COMMON OPTIONS As you will see, Parker offers a variety of Control products. As such, some of the options mentioned below may not be available on all valve models. Consult the model coding and dimensions of each valve for specifics. Here are some of the common options available. Adjustment Types: Parker offers four primary types of adjustments for most of the flow control products. Samples of these types are shown below. Please note all options may not be available for all valves. Consult the individual catalog pages for more details. Screw Adjustment - Valve can be adjusted with an allen wrench. Lock nut included to maintain desired setting after adjustment. This is the most common adjustment option available on most Parker products. Knob Adjustment - An aluminum knob is added to the standard screw adjustment. A lock knob is provided to help maintain the desired setting after adjustment. Parker offers knob conversion kits for most flow control valves. For kit numbers consult the individual valve pages. Fixed Style - In most cases, the Fixed Style product is a screw adjustable product with a steel collet threaded over the adjustment. These valves are preset at the factory. Should the valve need to adjusted, the star washer and aluminum plate can be removed from the top of the assembly exposing the adjustment. Tamper Resistant - The tamper resistant option is a screw adjustable valve with a steel cap installed to conceal the adjustment. The cap is designed so the internal edges clamp into the groove of the valve adapter. Once the cap is installed, it cannot be removed without damaging the cap and the valve. When a valve is ordered with the tamper resistant option, it will be preset at the factory, and the cap will be included in a separate plastic bag to allow for fine tuning at the customer site. Parker offers tamper resistant cap conversion kits for most flow control valves. For kit numbers consult the individual valve pages. Seals: The Winner s Circle products feature a standard 431 Polyurethane D -Ring. The D -Ring eliminates the need for backup rings.the majority of the products are available in Nitrile or Fluorocarbon Seals. You should match the seal compatibility to the temperature and fluid being used in your application. Fine Meter Options: Fine meter needles are offered on some needle valve series. When this option is specified, the standard needle is replaced by a slotted needle. The slotted needle restricts substantially more flow giving you finer control in the small flow ranges. Obviously, the maximum flow capacity of the needle valve is decreased with the fine meter option. Coarse Needle Fine Needle 1

3 Catalog HY15-352/US Tips PRODUCT TYPES / APPLICATIONS Control Needle Valve Needle valves provide uncompensated adjustable flow control of a desired function. They are ideal for applications where general control of hydraulic flow is needed, like in a bleed off circuit. When used with a compensator spool, a pressure compensated system can be obtained. OPERATION - The valve acts as a fixed orifice in a hydraulic circuit. The effective size of the orifice increases as the tapered needle is opened. Shutoff is provided when fully closed. While a needle valve will meter flow regardless of the flow path, flow from port 2 to 1 is preferred. When you flow in the reverse direction (1 to 2), pressure forces work on the nose of the needle in an effort to drive it off of its seat. As such, all leakage conditions found in the catalog are based on flow from side to nose (port 2 to port 1). In addition, the adjustment will be harder to turn due to the added force. Needle with a Reverse Needle valves with reverse check functions are sometimes also referred to as flow control valves. As the name implies, these valves provide uncompensated adjustable speed control in one direction and allow free flow in the opposite direction. When used with a compensator spool, a pressure compensated system can be obtained. OPERATION - With flow entering the side of the cartridge (port 2), the needle acts as a fixed orifice. The effective size of this orifice is increased as the needle is opened controlling the output flow to port 1. With flow entering the nose (port 1), the check ball inside the needle is unseated allowing free flow to port 2. P.C. Regulator compensated flow regulators maintain a regulated flow regardless of changes in load or inlet pressure. They are commonly used to accurately control an actuator function. They can be used in meter-in or meter-out applications. OPERATION - The valve consists of a control orifice within a normally open, spring biased compensator spool. through the control orifice produces a pressure drop across the compensator spool. When inlet flow exceeds the flow setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle or restrict flow; thus maintaining consistent flow through the valve. In the reverse direction, flow is metered, but not pressure compensated. Inlet Reg. 2

4 Catalog HY15-352/US Tips P.C. Control compensated flow controls are pressure compensated regulators with a reverse flow check valve. They provide constant regulated flow in the one direction regardless of changes in load pressure. in the reverse direction is non-regulated, free flow. They can be used in meter-in or meter-out applications. Control Adjustable Most adjustable pressure compensated flow controls have a limited adjustment range. You will see in our catalog that we use the term tuneable for the FR11 and 11 valves. This means they are only adjustable within a pre-set range. The FA11, J2E2, J4E2 and J4C2 are fully adjustable. Keep this adjustment capability in mind when you select a flow control. OPERATION - When flow enters the nose (port 1) of the cartridge, it passes through a control orifice. This control orifice creates a pressure differential across the regulating spool. As the inlet flow increases, the pressure differential across the regulating spool increases, allowing the regulating spool to overcome its spring force and begin to shift. As it shifts, it throttles to maintain a constant flow. When used in conjunction with a fixed displacement pump, a relief valve between pump and valve is needed. Full flow is allowed in the reverse direction (port 2 to 1). Priority Style P.C. Regulator Priority style pressure compensator regulators maintain constant priority flow to one leg of the circuit regardless of changes in load or inlet pressure. Once this priority flow requirement is satisfied, the excess flow is diverted and can be used in another leg of the circuit. These valves are usually used in meter-in applications. OPERATION - The valve consists of a control orifice within a spring biased compensator spool. The priority port is normally open while the bypass port is normally closed. As flow enters the inlet of the cartridge and passes through the control orifice, a pressure differential is created across the compensator spool. When the inlet flow exceeds the setting of the valve, the force produced by this pressure differential exceeds the spring force and shifts the compensator spool; opening up the bypass port, and bypassing the excess flow. If load pressure at the bypass port is greater than the load pressure at the priority port, the compensator spool will further shift restricting the priority flow to that of the valve setting. Caution: If the priority line is blocked so that no flow can pass through the control orifice, the compensator spool will shift, blocking the bypass port and allowing inlet pressure to go to full system relief pressure. These valves do not provide a pressure relieving function, so it is common to place an external relief valve downstream of port 3 to prevent a no flow condition. 3

5 Catalog HY15-352/US Tips Compensator Compensator valves are used to provide pressure compensated control across an external fixed or adjustable orifice. Parker offers both the restrictive type of compensator and a priority style. Control Restrictive Type OPERATION - Restrictive Type: Priority Type Inlet flow (upstream of the orifice) is split with one portion going to the compensator port inlet (port 1), the other portion passes through the (4) orifice to the supply port (port 3). As pressure drop across the orifice reaches the selected compensator pressure drop, the higher pressure (pre-orifice) at port 1 starts to shift the compensator spool into throttling position. The valve works to maintain a constant pressure drop across the orifice. Priority Type: through the external orifice into the supply port (port 4) produces a pressure drop across the compensator spool. When the inlet pressure exceeds the initial setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the compensator spool to throttle or restrict the flow, thus maintaining constant flow through the priority port (port 3). The excess flow is bypassed to port 2. Regulated port flow must be maintained for bypass flow to continue. Divider / Combiner divider / combiner valves are used to proportion the flow from a single source into two actuators. In the reverse mode, the valve takes the flow from the two sources and combines it into one flow. When attempting to synchronize two cylinders Divider Outlets Combiner Inlets Divider Inlet Combiner Outlet with a flow/divider combiner valve, please consider that the flow accuracy is +1%. A crossover relief can be used to help re-synchronize the cylinders by bottoming them out after several cycles. OPERATION - When flow enters the divider inlet port, it will pass through orifices in each of the interconnected spools. The flow passing through the orifices creates a pressure drop which pulls the two spools away from each other. The flow then passes to the two divider outlet ports. The division of flow (i.e. 5-5, 6-4, 66-33, etc.) is determined by the orifice sizes in the two spools.when flow is being combined, it enters the valve through two combiner inlets. The pressure drop across the orifices pulls the two spools together. The combined flow then passes through the combiner outlet. 4

6 Catalog HY15-352/US Information Needle Valve Series J2A2 General Description Cartridge Style Needle Valve. For additional information see Tips on pages 1-4. Features Shuts off to a very low leakage level High flow capacity from a small cavity Good adjustment sensitivity - ideal for fine control Good contamination tolerant Adjustable and tamperproof versions available All external parts zinc plated Specifications Rated Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 45 LPM (12 GPM) 42 Bar (6 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.11 kg (.24 lbs.) Cavity C8-2 (See Section for more details) Form Tool Rougher None Finisher NFT8-2F Performance Curves (Through cartridge only) Low Drop vs. 1 to 2 & 2 to 1 Drop ( P) PSI Bar Turn Hydraulic Oil 15 1 F (32 cst) LPM 2 GPM (Q) High Drop vs. 1 to 2 & 2 to 1 Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) ½ Turn 1 1½ LPM 2 GPM (Q) Fully Open Fully Open

7 Catalog HY15-352/US Needle Valve Series J2A2 Information Dimensions Millimeters (Inches) 5 AF Hex socket 2.5 (.81) max 22 (.87) 17 AF Hex. 12 Nm (9 lb. ft.) 22 AF Hex. 4 Nm (3 lb. ft.) 27.2 (1.7) 3/4" - 16 UNF Ordering Information J2A2 8 Size Needle Valve Adjustment Style Seals Body Material Port Size Code Adjustment Style Z Screw Adjust (Std.) W Knob Adjust T Tamper Resistant Cap (TC113) Code Seals / Kit. No. N Nitrile, Buna-N (Std.)/ (SK35N-1) V Fluorocarbon / (SK35V-1) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-2-*4P) 6P 3/8 NPTF (B8-2-*6P) 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) * Add A for aluminum, omit for steel. 6

8 Catalog HY15-352/US Information Needle Valve Series NVH81 General Description Cartridge Style Needle Valve. For additional information see Tips on pages 1-4. FINE ADJUSTMENT Features Hardened, precision ground parts for durability Compact size for reduced space requirements Fine adjustment needle option available for precise adjustment Polyurethane D -Ring eliminates backup rings and prevents hydrolysis Valve meters flow in either direction, but (2 to 1) is the preferred direction for lowest leakage at shut off All external parts zinc plated COARSE ADJUSTMENT Specifications Rated Fixed 37.9 LPM (1 GPM) Adjusted Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 38 Bar (55 PSI) All parts steel. All operating parts hardened steel. -45 C to C ( D -Ring) (-5 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.1 kg (.2 lbs.) Cavity No. C8-2 (See Section for more details) Form Tool Rougher None Finisher NFT8-2F Performance Curves vs. Inlet (Through cartridge only) Drop ( P) Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) Coarse Adjustment 1 Turn 2 Turns 3 Turns Full Open LPM GPM (Q) PSI Bar Turn 2 Turns Hydraulic Oil 15 1 F (32 cst) 3 Turns Full Open Fine Adjustment LPM GPM (Q)

9 Catalog HY15-352/US Needle Valve Series NVH81 Information Dimensions Millimeters (Inches) 25.4 (1.) Dia. Knob 36.6 (1.44) 36.6 (1.44) 42.4 (1.67) 3/4-16 UNF-2A Thread 7/8" Hex Nm (23-27 lb. ft.) 12.6 (.5) 27.2 (1.7) THIRD-ANG PROJECTION Screw/Knob Version Tamper Resistant Version Ordering Information NVH81 8 Size Needle Valve Needle Adjustment Style Seals Body Material Port Size Code Needle Omit Coarse F Fine Code Adjustment Style K Knob Adjust ( ) S Screw Adjust T Tamper Resistant Cap (717943) Code Seals / Kit. No. Omit D -Ring / (SK8-2) N Nitrile / (SK8-2N) V Fluorocarbon / (SK8-2V) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-2-*4P) 6P 3/8 NPTF (B8-2-*6P) 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) * Add A for aluminum, omit for steel. 8

10 Catalog HY15-352/US Information Needle Valve Series NVH11 General Description Cartridge Style Needle Valve. For additional information see Tips on pages 1-4. FINE ADJUSTMENT Features Hardened, precision ground parts for durability Compact size for reduced space requirements Fine adjustment needle option available for precise adjustment Polyurethane D -Ring eliminates backup rings and prevents hydrolysis Valve meters flow in either direction, but (2 to 1) is the preferred direction for lowest leakage at shut off All external parts zinc plated COARSE ADJUSTMENT Specifications Rated Fixed 6 LPM (16 GPM) Adjusted 6 LPM (16 GPM) Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 38 Bar (55 PSI) All parts steel. All operating parts hardened steel. -45 C to C ( D -Ring) (-5 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.18 kg (.4 lbs.) Cavity C1-2 (See Section for more details) Form Tool Rougher None Finisher NFT1-2F Performance Curves vs. Inlet (Through cartridge only) Drop ( P) Drop ( P) PSI Bar Coarse Adjustment Hydraulic Oil 15 1 F (32 cst) 1 Turn 2 Turns 3 Turns LPM GPM (Q) 1 PSI Bar Turn 2 Turns LPM GPM (Q) 1 4 Turns Full Open Hydraulic Oil 15 1 F (32 cst) 3 Turns 4 Turns 5 Turns Turns Full Open Fine Adjustment

11 Catalog HY15-352/US Needle Valve Series NVH11 Information Dimensions Millimeters (Inches) 25.4 (1.) Dia. Knob 34.2 (1.35) 34.2 (1.35) 41.9 (1.65) 7/8-14 UNF-2A Thread 1" Hex Nm (37-41 lb. ft.) 31.7 (1.25) Ø 15.8 (.62) THIRD-ANG PROJECTION Screw/Knob Version Tamper Resistant Version Ordering Information NVH11 1 Size Needle Valve Needle Adjustment Style Seals Body Material Port Size Code Needle Omit Coarse F Fine Code Adjustment Style K Knob Adjust ( ) S Screw Adjust T Tamper Resistant Cap (717943) Code Seals / Kit. No. Omit D -Ring / (SK1-2) N Nitrile / (SK1-2N) V Fluorocarbon / (SK1-2V) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-*6B) * Add A for aluminum, omit for steel. Steel body only. 1

12 Catalog HY15-352/US Information Needle Valve Series J6A2 General Description Cartridge Style Needle Valve. For additional information see Tips on pages 1-4. Features Shuts off to a very low leakage level High flow capacity Good adjustment sensitivity - ideal for fine control Good contamination tolerant Adjustable and tamperproof versions available All external parts zinc plated Specifications Rated Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 225 LPM (6 GPM) 42 Bar (6 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.38 kg (.84 lbs.) Cavity C16-2 (See Section for more details) Form Tool Rougher None Finisher NFT16-2F Performance Curves (Through cartridge only) Low Drop vs. 1 to 2 & 2 to 1 Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) 1 Turn LPM 5 1 GPM (Q) High Drop vs. 1 to 2 & 2 to 1 Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) LPM 5 1 GPM (Q) Fully Open 1 Turn 2 Turns

13 Catalog HY15-352/US Needle Valve Series J6A2 Information Dimensions Millimeters (Inches) 25.5 (1.) (1.84) (.88) max 5 AF Hex socket 17 AF Hex. 12 Nm (9 lb. ft.) 38 AF Hex. 1 Nm (74 lb. ft.) 1-5/16" - 12 UNF Ordering Information J6A2 16 Size Needle Valve Adjustment Style Seals Body Material Port Size Code Adjustment Style Z Screw Adjust (Std.) W Knob Adjust T Tamper Resistant Cap (TC113) Code Seals / Kit. No. N Nitrile, Buna-N (Std.)/ (SK357N-1) V Fluorocarbon / (SK357V-1) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 12P 3/4 NPTF (B16-2-*12P) 16P 1 NPTF (B16-2-*16P) 8T SAE-8 (B16-2-*8T) 12T SAE-12 (B16-2-*12T) 16T SAE-16 (B16-2-*16T) 12B 3/4 BSPG (B B) 16B 1 BSPG (B16-2-*16B) * Add A for aluminum, omit for steel. Steel body only. 12

14 Catalog HY15-352/US Information Needle Valve Series J2B2 General Description Poppet Type Needle Valve with Reverse. For additional information see Tips on pages 1-4. Features Shuts off to a very low leakage level Good adjustment sensitivity - ideal for fine control Good contamination tolerant Adjustable and tamperproof versions available All external parts zinc plated Specifications Rated Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 3 LPM (8 GPM) 42 Bar (6 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.11 kg (.24 lbs.) Cavity C8-2 (See Section for more details) Form Tool Rougher None Finisher NFT8-2F Performance Curves (Through cartridge only) Low Drop vs. 1 to 2 & 2 to 1 Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) 2¾ Turns LPM 5 1 GPM (Q) High Drop vs. 1 to 2 Drop ( P) PSI Bar LPM 5 1 GPM (Q) 2½ 2 Open Hydraulic Oil 15 1 F (32 cst) 3 Turns Fully Open 2¾ ½ Fully Open

15 Catalog HY15-352/US Needle Valve Series J2B2 Information Dimensions Millimeters (Inches) 5 AF Hex socket 18.5 (.73) max 22 (.87) 17 AF Hex. 12 Nm (9 lb. ft.) 22 AF Hex. 4 Nm (3 lb. ft.) 27.2 (1.7) 3/4" - 16 UNF Ordering Information J2B2 8 Size Needle Valve Adjustment Style Seals Body Material Port Size Code Adjustment Style Z Screw Adjust (Std.) W Knob Adjust T Tamper Resistant Cap (TC113) Code Seals / Kit. No. N Nitrile, Buna-N (Std.)/ (SK35N-1) V Fluorocarbon / (SK35V-1) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-2-*4P) 6P 3/8 NPTF (B8-2-*6P) 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) * Add A for aluminum, omit for steel. 14

16 Catalog HY15-352/US Information General Description Needle Valve with a Reverse. Also known as a Control Valve. For additional information see Tips on pages 1-4. Needle Valve Series FV11 and FV12 FV11 Features Hardened, precision ground parts for durability Compact size for reduced space requirements Fine thread needle option available for precise adjustment All external parts zinc plated Specifications Rated FV11 45 LPM (12 GPM) FV12 23 LPM (6 GPM) Maximum Inlet Cartridge Material 21 Bar (3 PSI) All parts steel. All operating parts hardened steel. Metered Free Free Inlet Metered Outlet Metered Inlet Free Outlet FV12 Metered Inlet Free Outlet Free Inlet Metered Outlet Operating Temp. Range/Seals -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Dimensions Millimeters (Inches) Fluid Compatibility/ Viscosity Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.23 kg (.5 lbs.) Cavity C1-2 (See Section for more details) Form Tool Rougher None Finisher NFT1-2F Screw and Knob Adjust - 1/4" Internal Hex. 1" Hex. 22 Nm (16 lb. ft.) 7/8-14 UNF-2A Thread 6.4 (.25) 38.1 (1.5) Dia. Knob 38.1 (1.5) 18.8 (.74) 31.7 (1.25) Ø 15.8 (.62) 15

17 Catalog HY15-352/US Information Performance Curves Metered vs. Drop (Through cartridge only) Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) FV Needle Valve Series FV11 and FV12 Drop ( P) PSI Bar Hydraulic Oil 15 1 F (32 cst) FV12 LPM GPM (Q) = No. of Turns CCW From Fully Closed. The number on each curve indicates the number of complete turns of the knob or screw adjustment from fully closed. When the metered flow is 22.5 LPM (6 GPM) and the adjustment is two complete turns from closed, the pressure drop will be 13.8 Bar (2 PSI). When the metered flow is 22.5 LPM (6 GPM) and the adjustment is five complete turns from closed, the pressure drop will be 3.5 Bar (5 PSI). LPM GPM (Q) = No. of Turns CCW From Fully Closed. The number on each curve indicates the number of complete turns of the knob or screw adjustment from fully closed (nonmetered flow). When the metered flow is 7.5 LPM (2 GPM) and the adjustment is two complete turns from closed, the pressure drop will be Bar (2275 PSI). When the metered flow is 7.5 LPM (2 GPM) and the adjustment is 3.75 turns from closed, the pressure drop will be 56.6 Bar (82 PSI). Ordering Information FV1 1 Size Control Valve Code Style 1 Coarse 2 Fine Code Adjustment Style K Knob Adjust (8428K) S Screw Adjust Style Adjustment Style Seals Code Seals / Kit. No. Omit Nitrile / (SK1-2N) V Fluorocarbon / (SK1-2V) Body Material Port Size Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B1-2-*4P) 6P 3/8 NPTF (B1-2-*6P) 8P 1/2 NPTF (B1-2-*8P) 6T SAE-6 (B1-2-*6T) 8T SAE-8 (B1-2-*8T) T8T SAE-8 (B1-2-T8T) 6B 3/8 BSPG (B1-2-6B) * Add A for aluminum, omit for steel. Steel body only. 16

18 Catalog HY15-352/US Information General Description Restrictive Style, Compensated Control Valve. For additional information see Tips on pages 1-4. P.C. Control Valve Series J2E2 Features Minimal flow change with pressure variation Reverse flow function Full adjustment from 1-2 LPM ( GPM) Hardened working parts for maximum durability Adjustable and tamperproof versions available All external parts zinc plated Specifications Rated Maximum Inlet Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity 2 LPM (5.3 GPM) 42 Bar (6 PSI) All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Performance Curves (Through cartridge only) Regulating Performance Regulated GPM LPM Hydraulic Oil 15 1 F (32 cst) Bar 1 3 PSI Drop Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.13 kg (.29 lbs.) Reverse Drop vs. PSI Bar Hydraulic Oil 15 1 F (32 cst) 29 2 Cavity C8-2 (See Section for more details) Form Tool Rougher None Finisher NFT8-2F Drop ( P) LPM 5 GPM (Q)

19 Catalog HY15-352/US Information Dimensions Millimeters (Inches) P.C. Control Valve Series J2E2 2 (.79) max 5 AF Hex socket Rotate adjuster CW to increase flow or CCW to decrease flow (1.29) 17 AF Hex. 12 Nm (9 lb. ft.) 22 AF Hex. 4 Nm (3 lb. ft.) 27.7 (1.9) 3/4" - 16 UNF Ordering Information J2E2 8 Size Compensated Control Valve Adjustment Style Optional Setting Seals Body Material Port Size Code Adjustment Style Z Screw Adjust (Std.) W Knob Adjust T Tamper Resistant Cap (TC113) Code Optional Setting Omit Omit for no setting* Specify setting if required (LPM) * Appropriate mid-range setting for Standard = 1 LPM Code Seals / Kit. No. N Nitrile, Buna-N (Std.)/ (SK35N-1) V Fluorocarbon / (SK35V-1) Code Body Material Omit Steel A Aluminum Code Port Size Body Part No. Omit Cartridge Only 4P 1/4 NPTF (B8-2-*4P) 6P 3/8 NPTF (B8-2-*6P) 4T SAE-4 (B8-2-*4T) 6T SAE-6 (B8-2-*6T) 6B 3/8 BSPG (B8-2-*6B) * Add A for aluminum, omit for steel. 18

20 Catalog HY15-352/US Information General Description Compensated Regulator Valve. NOTE: When used with a fixed displacement pump, pressure to the cartridge must be controlled by a relief valve located between the pump and the FR11 cartridge. For additional information see Tips on pages 1-4. Features Hardened, precision ground parts for durability Cartridge design Acts as a fixed orifice in reverse flow condition All external parts zinc plated Specifications Rated Fixed 22.5 LPM (6 GPM) Adjusted 26.5 LPM (7 GPM) Maximum Inlet 245 Bar (35 PSI) Accuracy (Fixed) 3.8 LPM (1 GPM) ±2% LPM (2-3 GPM) ±15% LPM (4-6 GPM) ±1% Adjustment Range (Adj. Version) Cartridge Material Operating Temp. Range/Seals Fluid Compatibility/ Viscosity ±3% Nominal All parts steel. All operating parts hardened steel. -4 C to C (Nitrile) (-4 F to +2 F) C to C (Fluorocarbon) (-25 F to +25 F) Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2 SSU (6 to 42 cst) Filtration ISO Code 16/13, SAE Class 4 or better Approx. Weight.23 kg (.5 lbs.) Cavity No. C1-2 (See Section for more details) Form Tool Rougher None Finisher NFT1-2F P.C. Regulator Valve Series FR11 Inlet Adjustable Style Outlet Performance Curves Regulated vs. (Through cartridge only) Regulated Regulated GPM LPM GPM LPM Hydraulic Oil 15 1 F (32 cst) 22.5 LPM (6 GPM) Fixed 11.3 LPM (3 GPM) Fixed 3.8 LPM (1 GPM) Fixed Inlet Bar PSI Inlet Hydraulic Oil 15 1 F (32 cst) Reg LPM (4.45 GPM) Adjustable (Max. Range) 16.7 LPM (4.45 GPM) Adjustable (Min. Range) Bar PSI Minimum Operating

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...

More information

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...

More information

Pressure Control Valves

Pressure Control Valves Catalog HY15-352/US Contents RELIEF VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/ DIRECT ACTING RDH42... C4-2... Direct Acting Relief, Poppet Type... 3.8/1... 35/5... 7-8

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

Check & Load Control Valves

Check & Load Control Valves Overview The HYDAC range of direct and pilot operated check valves provide a broad selection of cartridge and inline products with operating pressure rating of up to 6 psi (4 bar). All valves have a one

More information

Check Valves Valve locator

Check Valves Valve locator Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()

More information

Republic/Manatrol Hydraulic and Pneumatic Control Valves. Catalog HY /US FOR POSITION ONLY

Republic/Manatrol Hydraulic and Pneumatic Control Valves. Catalog HY /US FOR POSITION ONLY Republic/Manatrol Hydraulic and Pneumatic Control Valves Catalog HY14-3000/US FOR POSITION ONLY Republic/Manatrol Valves Hydraulic and Pneumatic Controls WARNING FAILUR OR IMPROPR SLCTION OR IMPROPR US

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

Hydraulic Pressure Control Valves

Hydraulic Pressure Control Valves Webtec Products Limited Hydraulic Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. RV 020 Direct In-Line Relief Valve 1 RV 025 Relief Valve 3 RV 050 Relief

More information

Check Valves. Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check Valves. Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Check Valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 7 L/min (60 USgpm) EATON Vickers Screw-In Cartridge Valves V-VLOV-MC00-E4 September, 007 - Check

More information

General Size Mounting 2-port in-line flange SAE 61 Mounting Position Ambient Temprature Hydraulic Maximum Operating Pressure

General Size Mounting 2-port in-line flange SAE 61 Mounting Position Ambient Temprature Hydraulic Maximum Operating Pressure Technical Information Pilot Operated Check Valve Series C5P General Description Series C5P pilot operated check valves have a similar design to the subplate mounted SVL series. The SAE flanges allow to

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms

More information

FLUTEC Pressure Relief Valves

FLUTEC Pressure Relief Valves FLUTEC Pressure Relief Valves Pressure Relief DB4E 1.1. up to 630 bar up to 30 l/min Connection housings 2 1. DESCRIPTION 1.1. GENERAL According to DIN -ISO 1219, DB4E are valves for oil hydraulic systems

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

PUMP UNLOADING VALVES

PUMP UNLOADING VALVES www.elwood.com PUMP UNLOADING VALVES 9 0 0 1 : 0 0 0 C E R T I F I E D C O M P A N Y Features Designed for the manufacturing environment, Elwood offers a full line of Pump Unloading equipment specifically

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

MONO BLOCK DIRECTIONAL CONTROL VALVE TS SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2

More information

High Speed Hydraulic Motors. Catalog HY /NA

High Speed Hydraulic Motors. Catalog HY /NA High Speed Hydraulic Motors Catalog HY13-20-0-001/NA 341 Introduction High Speed Features High Starting Torque typically 90% of running torque. Smooth Output Torque throughout the entire speed range of

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Series PVP Variable Volume, Piston Pumps

Series PVP Variable Volume, Piston Pumps Variable Volume, Piston Pumps Catalog 2600-102/USA Introduction Quick Reference Data Chart Pump Model Displacement cc/rev (In 3 /rev) Pump Delivery *Approx. Noise Levels db(a) Horsepower At Pressure @

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T LV22RFSTKLB A2 B2 A1 B1 P LV22RFSTKABW FEATURES: O RING PORTS to eliminate leakage. FOURTH POSITION REGEN allows cylinder to rapidly extend. POWER

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES

SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES ABOUT THE SESSION This session deals with check valves, flow control valves, its functions, operations and application. INTRODUCTION Check Valve:

More information

Pressure Relief Valve, Direct Operated Model DBD (Series 1X)

Pressure Relief Valve, Direct Operated Model DBD (Series 1X) ressure Relief Valve, Direct Operated Model DBD (Series 1X) Sizes 6 to 30... 9150 SI (630 bar) 87 GM (330 L/min) RA 25 402/06.98 Replaces: 05.94 Direct operated, fast response pressure relief valve hree

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Velocity and Feed Controllers

Velocity and Feed Controllers VC with Fine Adjustment 78 ACE VC s are sealed hydraulic units fitted with a high precision metering element. When the piston rod is depressed the hydraulic oil is forced through the adjustable precision

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

RJV1-05 2(4) 1. Functional Description HA /2012. Pilot Operated Cartridge Check Valves. Replaces HA /2011

RJV1-05 2(4) 1. Functional Description HA /2012. Pilot Operated Cartridge Check Valves. Replaces HA /2011 Pilot Operated Cartridge Check Valves RJV-05 HA 5 8/0 Size 05 50 bar (600 PSI) 0 L/min (5. GPM) Replaces HA 5 0/0 Cartridge valve for manifold mounting and with subplate with subplate - enables direct

More information

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109 INDEX Description Page Delta Power Rotary Flow Divider, Positive Displacement (Application Data) 36 P Series, Equal Flow Two Sections 39 P Series, Equal Flow Multi-Sections 40 PM Series, Equal Flow Multi-Sections

More information

KDG3V-5/7/8, 10 Series

KDG3V-5/7/8, 10 Series Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5

More information

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES CONTINENTAL HYDRAULICS PR*SP - PR*SPU PILOT OPERATED PRESSURE RELIEF VALVE SERIES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM POWERFUL PR*SP - PR*SPU

More information

THROTTLE MODULES TC1G-01 / 03 (1 / 8, 3 / 8) THROTTLE AND CHECK MODULES TC2G-01 / 03 (1 / 8, 3 / 8)

THROTTLE MODULES TC1G-01 / 03 (1 / 8, 3 / 8) THROTTLE AND CHECK MODULES TC2G-01 / 03 (1 / 8, 3 / 8) THROTTLE MOULES - / 3 ( / 8, 3 / 8) THROTTLE AN CHECK MOULES TCG- / 3 ( / 8, 3 / 8) Gasket Specifications / Model Number esignation Up to MPa (363 PSI), 8 L/min (. U.S.GPM) Pub. EC-3 Used as pilot choke

More information

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load

More information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19 Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR

More information

PowrFlow HPV Series Axial Piston Pumps

PowrFlow HPV Series Axial Piston Pumps PowrFlow HPV Series Axial Piston Pumps HPV SERIES AXIAL PISTON PUMPS RELIABLE POWER FOR ANY HYDRAULIC SYSTEM Product Description What Makes PowrFlow HPV Series Axial Piston Pumps Your Best Buy? Variable

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics. SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

IFP SINGLE VANE PUMPS V10/V20 - V210/V230

IFP SINGLE VANE PUMPS V10/V20 - V210/V230 IFP SINGLE VANE PUMPS V10/V20 - V210/V230 * High Performance * Low Cost * Extended Life * Versatile * Compact * Quiet Operation * Balanced Cartridge Design C:\Program Files\ACAD2000\CATELOG\NDcatalogue\pictures\V10&V20.bmp

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems.

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. Section 12 U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. R84 Regulator and C84 Regulator Configurations for Soft Drink Carbonator

More information

Check Valves. Pilot Operated Check Valves 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Vickers. Basic Characteristics.

Check Valves. Pilot Operated Check Valves 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Vickers. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4535VQSV10* ***** ******* 20* Released M 2497 S

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4535VQSV10* ***** ******* 20* Released M 2497 S Service Data Vickers Vane Pumps Vane Type Triple Pump (F3) 4535VQSV10* ***** ******* 20* Released 08 01 95 M 2497 S 10 SAE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin Bolt

More information

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit

More information

IFP A10VSO VARIABLE AXIAL PISTON PUMPS. Available sizes: NOMINAL PRESSURE 4000 psi [280 bar] PEAK PRESSURE 5100 psi [350 bar] FEATURES SECTIONAL VIEW

IFP A10VSO VARIABLE AXIAL PISTON PUMPS. Available sizes: NOMINAL PRESSURE 4000 psi [280 bar] PEAK PRESSURE 5100 psi [350 bar] FEATURES SECTIONAL VIEW IFP A10VSO VARIABLE AXIAL PISTON PUMPS Available sizes: 18 1.10 in3/rev [18 cm3/rev] 28 1.71 in3/rev [28 cm3/rev] 45 2.75 in3/rev [45 cm3/rev] 71 4.33 in3/rev [71 cm3/rev] 100 6.10 in3/rev [100 cm3/rev]

More information

Pilot Operated Check Valves Model SV/SL (Series 4X)

Pilot Operated Check Valves Model SV/SL (Series 4X) R 68/06.98 Size 0 to 0 Pilot Operated Check Valves Model SV/SL (Series ) 600 PSI (5 bar)... 5 GPM (550 L/min) R 68/06.98 Replaces: 05.9 Pilot operated check valve, with leak-free closure in checked direction

More information

PVH131/141 Variable Displacement Piston Pump - 11 Design

PVH131/141 Variable Displacement Piston Pump - 11 Design Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US Series PAVC Variable Displacement Piston Pumps zp1 Catalog HY28-2662-CD/US 1 Introduction Series PAVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *Approx. Noise

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

PILOT OPERATED CHECK VALVE - Series VC4V

PILOT OPERATED CHECK VALVE - Series VC4V PILOT OPERTED CHECK VLVE - Series VCV Veljan Pilot Operated Check Valves VCV are with pilot control for hydraulic unlockg. These are sprg-loaded poppet type valves. Mountg configuration of VCV are accordg

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

HOSE, TUBE, AND PIPE CLAMPS

HOSE, TUBE, AND PIPE CLAMPS HOSE, TUBE, AND PIPE CLAMPS HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions 5 Heavy Duty Clamps

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Pressure Relief and Regulating Valves

Pressure Relief and Regulating Valves Pressure Relief and Regulating Valves With blocked center directional valves and variable displacement pumps, or open center directional valves and fixed displacement pumps where fast response, low leakage

More information

Coreless Spin-on Filters

Coreless Spin-on Filters The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old spin-on style can. This new design provides all of the benefits of high efficiency,

More information

HPV SERIES AXIAL PISTON PUMPS

HPV SERIES AXIAL PISTON PUMPS INDEX COMPENSATED VOLUMETRIC THEORETICAL FLOW@ MODEL MAXIMUM CONTINUOUS FLANGE PAGES DISPLACEMENT 17 RPM SERIES MOUNTING.88 CU. IN./REV. 6.67 GPM HPV-6B35 30 PSI SAE A 2-BOLT* 9-15 1.26 CU. IN./REV. 9.55

More information

Flow divider (flow distributor), type TQ

Flow divider (flow distributor), type TQ Flow divider (flow distributor), type TQ Pressure p max = 0 bar Flow Q CN max = 00 lpm Share ratio = :. General Task Flow dividers type TQ are self-regulating valves, which largely irrespective of the

More information

IL8 Series. Medium Pressure Filters

IL8 Series. Medium Pressure Filters Medium Pressure Filters 88 Applications Applications for IL8 series filters Lube oil systems Power generation plants Test stands Primary metal equipment Pulp & paper equipment Offshore drilling and oil

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

AXIAL PISTON PUMPS PV S E R I E S 2 0 C L O S E D C I R C U I T

AXIAL PISTON PUMPS PV S E R I E S 2 0 C L O S E D C I R C U I T GENERAL DESCRIPTION Axial piston variable displacement pumps, Series 20, are of swash plate construction with variable flow capatibility suitable for hydrostatic transmissions with closed circuit. The

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief Hydraulically pilot operated cartridge check valves RHC and RHCE without and with hydraulic pre-relief Pressure p max = 700 bar Flow Q max = 0 lpm Symbols RHC RHCE 1. General These devices are designed

More information

Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653)

Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653) SPECIFICATIONS AND PARTS Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653) Serial Codes GDV and GDL Read and understand all of the instructions and safety information in this manual before

More information

THE BASICS OF PRESSURE REGULATORS

THE BASICS OF PRESSURE REGULATORS THE BASICS OF PRESSURE REGULATORS Contents The Basics of Pressure Regulators Material Fluid used (gas, liquid, toxic or flammable) Temperature Operating Pressures Flow Requirements Size & Weight Pressure

More information

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications Technical Catalog PVQ10 PVQ13 PVQ20 PVQ25 PVQ32 PVQ40 PVQ45 Table of Contents Introduction......................................................................................................

More information

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL ATEX 94/9/EC SIL3 IEC 61508 GOST-R TYPE APPROVAL 95 90 75 Stroke 15 0 4. Universal and anti-blowout drive shaft It permits an easy conversion from parallel to diagonal square and vice versa. It is also

More information

P630 High Flow Gas Regulator

P630 High Flow Gas Regulator P630 High Flow Gas Regulator Stainless Steel Internals are Standard Steel Units comply with NACE MR0175 Durable Powder Coated Exterior Wide Range of Flow Capacities The P630 is a spring loaded, direct-operated

More information

Pressure relief valve, pilot operated

Pressure relief valve, pilot operated Pressure relief valve, pilot operated RE 7/0.0 Replaces: 08.0 /8 Type DB. K Nominal sizes 6 and 0 Component series 4X Maximum operating pressure bar Maximum flow 60 l/min (NS6) 00 l/min (NS0) K478- Overview

More information

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design. Revised 11/01/97

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design. Revised 11/01/97 Service Data Vickers Piston Pumps PVH74/81 Variable Displacement Piston Pump - 11 Design Revised 11/01/97 Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque Limiter

More information

Pilot-operated Check Valves ERVE. up to 350 bar up to 300 l/min. Cartridge valves E / Connection housings

Pilot-operated Check Valves ERVE. up to 350 bar up to 300 l/min. Cartridge valves E / Connection housings Pilot-operated Check Valves ERVE up to 350 bar up to 300 l/min Cartridge valves Connection housings 1. DESCRIPTION 1.1. GENERAL In accordance with DIN-ISO 1219, HYDAC pilot-operated check valves, type

More information

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically

More information

SIMPLE HYDRAULIC SYSTEM. Understanding Mobile Hydraulics. Ram Handle. Reservoir Pump SYSTEM COMPONENTS. FORCE America Inc.

SIMPLE HYDRAULIC SYSTEM. Understanding Mobile Hydraulics. Ram Handle. Reservoir Pump SYSTEM COMPONENTS. FORCE America Inc. Understanding Mobile Hydraulics. SIMPLE HYDRAULIC SYSTEM Ram Handle SYSTEM COMPONENTS Reservoir Pump 1 COMPONENTS PRIME MOVERS Reservoirs Dissipate heat store fluid Strainer/filters Clean fluid Prime movers

More information

DENISON HYDRAULICS high performance hydraulic new vane motor series M5B - M5BS - M5BF

DENISON HYDRAULICS high performance hydraulic new vane motor series M5B - M5BS - M5BF Back to Content DENISON HYDRAULICS high performance hydraulic new vane motor series M5B - M5BS - M5BF Publ. 2 - EN1702 - A 01 / 99 / 2500 / FB Replaces : CHARACTERISTICS - M5B* SERIES LOW NOISE MOTOR 12

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

Variable displacement axial piston pump type V30Z

Variable displacement axial piston pump type V30Z Variable displacement axial piston pump type V30Z Twin pump (back-to-back) for open circuit Operating pressure p max Displacement V max = 420 bar (6000 psi) = 2x115 ccm/rev See also: Variable displacement

More information

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US

Pneumatic Grippers Parallel and Angular Grippers. Catalog 1900-2/US Pneumatic Grippers Parallel and Angular Grippers Catalog 19-2/US Catalog 19-2/US OContents GPR Series Rotary vane driven design GPR GPCR Series P5G-HPM(C) Series P5G-HP Series GPT Series P5G-AP Series

More information

Pressure relief valve, pilot-operated, with pulling function, seat design with pressure sequencing and pressure cut-off stage

Pressure relief valve, pilot-operated, with pulling function, seat design with pressure sequencing and pressure cut-off stage Pressure relief valve, pilot-operated, with pulling function, seat design with pressure sequencing and pressure cut-off stage Type MHDBB and MHDBL RE 6461 Edition: 016-04 Frame sizes 16,, 3 Component series

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

ROTARY GEAR FLOW DIVIDERS

ROTARY GEAR FLOW DIVIDERS ROTARY GEAR FLOW DIVIDERS Concentric AB Innovation + Technology = Sustainability GC and D Series Rotary Gear Flow Dividers Intensifier - Combiner (European and U.S. Versions) Field-proven Concentric Hydraulic

More information

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

Suction Return Series Tanktop Mounted Suction & Return Line Filters - Types SR1 & SR2

Suction Return Series Tanktop Mounted Suction & Return Line Filters - Types SR1 & SR2 Suction Return Series Tanktop Mounted Suction & Return Line Filters - Types SR1 & SR2 Max. 25 I/min - 1 bar Filters both open and closed loop oil circuits through one filter Reduced risk of pump cavitation

More information

Rexroth Hydraulics. Pressure relief valve, direct operated, Type DBD RE /03.98

Rexroth Hydraulics. Pressure relief valve, direct operated, Type DBD RE /03.98 RE 25 402/03.98 Replaces: 08.97 ressure relief valve, direct operated, ype DBD Nominal sizes 6 to 30 Series 1X Maximum operating pressure 630 bar Maximum flow 330 L/min H/A 5585/96 ype DBD 1X/ Contents

More information

Hydraulic Pump/Motor Division. John Duba Product Manager Piston Pumps. Hydraulic Pump/Motor Division

Hydraulic Pump/Motor Division. John Duba Product Manager Piston Pumps. Hydraulic Pump/Motor Division John Duba Product Manager Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000

More information

MOTORS M HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MOTORS M HYDRAULIC MOTORS T E C H N I C A L C A T A L O G MOTORS M HYDRULIC MOTORS T E C H N I C L C T L O G Fixed displaced axial piston motors POCLIN HYDRULICS Displacement cm³/rev [in³/rev.] M M1 M2 M3 From 7,7 [.43] to 17,84 [1.9] From 9,8 [.55] to 2,31 [1.24]

More information

Displacements cm 3 /r [in 3 /r] Design code -002 344 [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] Char-Lynn HP30 Motor

Displacements cm 3 /r [in 3 /r] Design code -002 344 [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] Char-Lynn HP30 Motor Char-Lynn HP30 Motor Design code -002 Displacements cm 3 /r [in 3 /r] 344 [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] Engineered for Performance For the past 55 years, Char-Lynn has been recognized

More information

Medium Pressure Filters. 15/40/80CN Series. MAX 600 I/min - 70 bar FEATURING. Medium pressure filters

Medium Pressure Filters. 15/40/80CN Series. MAX 600 I/min - 70 bar FEATURING. Medium pressure filters 1/4/8CN Series MAX I/min - 7 bar FEATURING 73 Medium pressure filters 1/4/8CN Series Features & Benefits Features bar fatigue rating (eight times that of a spin-on) Diametral (side) seal between head and

More information

Series Regulators - Pressure Reducing

Series Regulators - Pressure Reducing 26-1000 Series Regulators - Pressure Reducing D26100538X012 Specifications For other materials or modifications, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3

More information

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series .Booklet 1.Booklet Hydraulic Motors out 2 out 1.Booklet R Geroler Element... 11 Displacements... [15] ** 75 [20] * Speed... Up to 10 RPM Pressure Bar [PSI]... 125 [1800] Cont. 165 [2400] Inter. Torque

More information

Line rupture protection valves type LB

Line rupture protection valves type LB Line rupture protection valves type LB Pressure p max Flow rate Q A max = 500 bar = 4... 160 lpm Screw-in versions Type LB...C In-line versions Type LB...G Type LB...F 1. General Line rupture protection

More information