indirect electro-pneumatic, pneumatic, manual, mechanical pneumatic spring, mechanical spring G1/8 6,5 890
|
|
- Patricia Boone
- 8 years ago
- Views:
Transcription
1 L-M UNVRSL istributors / - / - UNVRSL Modular System: possibility to create a lot of different valves with a short number of basis elements - ontrol: manual, mechanical,, electric - Traditional UNVR spool system: fluctuating seals of special compount to reduce frinction and prevent sticking - igh flow rate, high cycle life, suitable for vacuum application - Modular sub-bases TNL RTRSTS low rate characteristics mbient temperature luid temperature luid outation system Ways/Positions Pressure ontrol onnections Nominal Ø Nominal flow rate (Nl/min) max +50 filtered air 50 μm not dehumidified, lubricated or not spool / N, / NO, / N-NO, 5/, 5/ max 0 bar indirect electro-,, manual, mechanical, / / >> / P (bar) P (bar) Qn (Nl/min) ONSTRUTV RTRSTS Valve body Seals ctuators Spool Sub-base LTR RTRSTS lectropilot oil Power consumption onnector Voltage Manual override / = die-cast zamak / = aluminium nitrile rubber technopolymer/aluminium aluminium zamak U,5 W () - 5 V () M 50 V - V - V - 0 V - 0 V with positions screw >> / P (bar) P (bar) Qn (Nl/min) P = Working pressure P = Supply pressure Qn= low rate Spool system valves _
2 L/M / - / UNVRSL distributors UNVR ROUP Modular system UNVRSL series MNL ONTROL all-push all-push for screw panel mounting all-push with dust protection Roller with dust protection 5 Roller 6 Uni-directional roller 7 idirectional side roller MNUL ONTROL Push-pull 9 Push 0 Rotating Selector 90 short/long Short/long Threaded indirect operation 5 irection operation for panel mounting 6 ndirect control for panel mounting LTR ONTROL 7 lectric U electropilot 9 Plate for external servoassistance 0 option angle plate P option angle plate PNUMT ONTROL Pneumatic OY / body 5/ body RTURN 5 Mechanical 6 Pneumatic not 7 / positions plate ottom plate 9 Pneumatic 0 Pneumatic _
3 L/M / - / UNVRSL distributors UNVR ROUP Modular system actuators/buttons PNUMT/MNL TUTORS MNUL PUS OVRR Spool system valves Pneumatic actuators 9 Rotating selector 7 Threaded indirect operation Pneumatic actuators 0 Rotating selector ndirect operation for panel mounting Roller operator posiotion Omni-directional 9 irect operation for panel mounting all operator position Push pull actuators OY 5 Operator with omni-directional antenna position Recessed button / ody 6 Roller operator position ead button 5/ ody 7 rticulated roller operator position 5 utton RTURN Key operator position 6 Lever operator 0 Mechanical Pneumatic not _5
4 L/M / - / UNVRSL distributors UNVR ROUP / Valves with direct mechanical operation L-00 M-00 L-0 M-0 L-00P M-00P L-0P M-0P L-06 M-06 L-0 M-0 L-0P M-0P L-05 M-05 L-0 M-0 L-05P M-05P L-0P M-0P L-0 M-0 L-0P M-0P / N-NO 5/ / N-NO 5/ / N-NO 5/ / N-NO 5/ / N-NO 5/ / N-NO 5/ / N-NO 5/ _6 ROLLR LVR not not UN-RTONL ROLLR LVR not not RTONL S ROLLR LVR LL-PUS not not ROLLR WT UST PROTTON not not LL-PUS WT UST PROTTON not not LL-PUS OR SRW PNL MOUNTN not not low rate (Nl/min) To get / NO version, supply the valve from port Pressure 0 0 bar for all part numbers Ø Weight Kg 0, 0, 0,5 0,5 0, 0, 0,6 0,6 0,0 0, 0,9 0,9 0, 0, 0,9 0, 0, 0, 0,9 0, 0, 0, 0,9 0, 0, 0, orce N Part no. L-00 L-00P M-00 M-00P L-0 L-0P M-0 M-0P L-06 M-06 L-0 L-0P M-0 M-0P L-05 L-05P M-05 M-05P L-0 L-0P M-0 M-0P L-0 L-0P M-0 M-0P omposition (a) ontrol ody (a) = see page _7 Tot L ,5 9,5 5 97,7 97,7,, 7 7,5, ,7 97,7,,
5 L/M / - / UNVRSL distributors omposition ONTROL OY RTURN UNVR ROUP / ROLLR LVR / UN-RTONL ROLLR LVR / N-NO / - / MNL SPRN >> N = Supply port = Use = xhaust = ontrol 0 = >> NO = xhaust = Use = Supply port = ontrol 0 = 5/ / / PNUMT NOT MPL Wrench 5 / LL-PUS / ROLLR WT UST PROTTON / LL-PUS WT UST PROTTON = Supply port - = Use - 5 = xhaust = ontrol = Spool system valves / LL-PUS OR SRW PNL MOUNTN Wrench _7
6 L/M / - / UNVRSL distributors UNVR ROUP / Valves with direct mechanical operation L-90 L-90P L-90 L-90P L-90 L-90P M-90 M-90P low rate (Nl/min) Ø Weight Kg orce N Part no. omposition (a) ontrol ody Tot L. / N-NO 5/ / N-NO LL-PUS not not LL-PUS OR SRW PNL MOUNTN not 0,6 0,6 0, 0, 0,6 0, L-90 L-90P M-90 M-90P L-90 L-90P 7 06,5, / not 0, 0,6 6 6 M-90 M-90P,5,5 To get / NO version, supply the valve from port Pressure 0 0 bar for all part numbers (a) = see page _9 _
7 L/M / - / UNVRSL distributors omposition ONTROL OY RTURN UNVR ROUP / N-NO / / LL-PUS / MNL SPRN >> N = Supply port = Use = xhaust = ontrol 0 = >> NO = xhaust = Use = Supply port = ontrol 0 = / LL-PUS OR SRW PNL MOUNTN 5/ / / PNUMT SPRN Wrench = Supply port - = Use - 5 = xhaust = ontrol = Spool system valves _9
8 L/M / - / UNVRSL distributors UNVR ROUP / - / Valves with direct mechanical operator for and mechanical actuators L-0 L-90 M-0 M-90 L- L-9 M- M-9 L-0P L-90P M-0P M-90P L-P L-9 M-P M-9P Thread Pressure bar low rate (Nl/min) Ø Weight Kg orce N Part no. LL-PUS / N / / / / not not, ,9 0, 0,6 0, L-0 L-0P L-90 L-90P 5/ / N 5/ / / / / SNSTV LL-PUS / / / / / / / / not not not not not not 0, 0 0, 0, , 0 0, 0 0, 0, 0, 0,6 0,9 0, 0,6 0, 0, 0, 0, 0,6 M-0 M-0P M-90 M-90P L- L-P L-9 L-9P M- M-P M-9 M-9P / N / - / = Supply port = Use = xhaust = ontrol 0 = / / ,5 5,5 5,5 6 J / / K L 6 M MX MX N 5/ / - / = Supply port - = Use - 5 = xhaust = ontrol = / / , ,7,5 5,5 5,5 J 6 K / / L M 6 N MX MX _0
9 L/M / - / UNVRSL distributors UNVR ROUP / - / Valves with direct mechanical operator for and mechanical actuators PNUMT N MNL TUTORS MNUL TUTORS Pneumatic operator -550 Recessed button LK R RN mplified operator ead button R LK R LK Roller operator position -56 utton RN R LK all-push operator position -56 ccident prevention rotating selector LK LK Operator with omni-directional antenna position Rotating selector LK LK -5-5 Roller operator position -570 Lever operator LK LK rticulated roller operator position omplete actuation with stroke,5, max stroke,7-57 Omnidirectional operator Key operator position -57 Push-pull operator LK -56 or actuators dimensions see section ccessories>ctuators Spool system valves _
10 L/M / - / UNVRSL distributors UNVR ROUP / Valves with direct operator for panel mounting actuators L- M- L-P M-P Pressure bar low rate (Nl/min) Ø Weight Kg orce N Part no. / N-NO LL-PUS not ,9 0, 6 5 L- L-P 5/ not , 0, 6 5 M- M-P To get / NO version supply the valve from port Recessed button YLLOW R RN -5Q -5Q -5Q / N-NO / ead button R LK -5Q -56Q utton RN R LK -55Q -57Q -59Q Lever operator LK -5Q >> N = Supply port = Use = xhaust = ontrol 0 = >> NO = xhaust = Use = Supply port = ontrol 0 = 5/ / = Supply port - = Use - 5 = xhaust = ontrol = or actuator dimensions see section ccessories>uttons _
11 L/M / - / UNVRSL distributors UNVR ROUP / - / Valves with indirect operator for panel mounting actuators L- L-9 M- M-9 L-P L-9P M-P M-9P Thread ttacco Pressione bar low rate (Nl/min) Ø Weight Kg orce N Part no. LL-PUS / N / / / / non non, ,0 0,9 0,7 0,6 L- L-P L-9 L-9P 5/ / / / / non non 0, 0 0, 0 0, 0, 0,9 0, M- M-P M-9 M-9P Recessed button LK R RN -5Q -5Q -5Q / N / - / R LK -5Q -56Q ead button R LK -5Q -56Q utton RN R LK -55Q -57Q -59Q ccident prevention rotating selector Lever operator LK LK LK -50Q -5Q -5Q = Supply port = Use = xhaust = ontrol 0 = / / 6 9 5/ / - / 0 0,5 5,5 5,5 6 J 7 7 K 0 0 L / / M N 6 O P MX MX Q Rotating selector Omnidirectional LK LK LK -5Q -5Q -55Q Spool system valves Push-pull operator LK -56Q = Supply port - = Use - 5 = xhaust = ontrol = / / , ,7,5 5,5 5,5 J 6 K 7 7 L 0 0 M / / N O 6 P Q MX MX or actuator dimensions see section ccessories>uttons _
12 L/M / - / UNVRSL distributors UNVR ROUP / Manually operated valves L-0 M-0 L-0 M-0 L-0P M-0P YLLOW P-9 R P-9R LK P-9N RN P-9V L-R L-R M-R M-R L-9R L-R M-9R M-R LON LVR STNR R UPON RQUST YLLOW LK SORT LVR STNR R UPON RQUST YLLOW LK RN L-6 M-6 STNR LVR R PUS-PULL(b) low rate (Nl/min) Ø Weight Kg orce N Part no. omposition (a) ontrol ody Tot L. / N-NO push-pull 0,9 5 L-0 0 5/ push-pull 0, 5 M-0 5 / N-NO 0,9 5 L-0 5/ 0, 5 M-0 7,5 / N-NO not 0, 5 L-0P 5/ not 0, 5 M-0P 7,5 UTTON / N-NO 0,0 5 L / 0, 5 M-6 / N-NO LON LVR (STNR R OLOUR) 0,7 0 L-R 6 5/ 0, 0 M-R,5 / N-NO 0,6 0 L-R 6 5/ / N-NO SORT LVR (STNR R OLOUR) 0,0 0,7 0 0 M-R L-9R,5 5/ 0, 0 M-9R / N-NO 0,6 0 L-R 5/ 0,0 0 To get / NO version, supply the valve from port (b) = valves are supplied without operator Pressure 0 0 bar for all part numbers M-R (a) = see pages _ Overall dimensions include operator _
13 L/M / - / UNVRSL distributors UNVR ROUP / Manually operated velves L-0 M-0 M-0 M-5 R P-95R M-0 R P-96R L- M- SORT LVR YLLOW P-9 R P-9R LK P-9N L- M- L- M- LON LVR R P-9R M- M- M- M- M-5 M-5 low rate (Nl/min) Ø Weight Kg orce N Part no. omposition (a) ontrol ody Tot L. ROTTN LVR (SLTOR UPON RQUST) (b) / N-NO rotating 0, 7 L / rotating 0,5 7 M-0,5 5/ c.c. rotating 0,5 7 M-0,5 5/ o.c. rotating 0, 7 M-5,5 5/ p.c. rotating 0, 7 M-0,5 90 LVR - POSTON (b) / N-NO 0,7,5 L- 79,5 5/ 0,,5 M- 96 / N-NO 0,7,5 5 L- 9 5/ 0,,5 5 M- 0 / N-NO 0, 9 L- 9 5/ 0, 9 M- 0 Spool system valves 5/ c.c. 0, 0,,5 5 0 M- M / o.c. 0, 0,,5 0 M- M / p.c. 0, 0, 7,5 5 0 M-5 M o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port (b) = valves are supplied without operator Pressure 0 0 bar for all part numbers (a) = see pages _ Overall dimensions include operator _5
14 L/M / - / UNVRSL distributors UNVR ROUP / Manually operated velves L-90 M-90 L-90 M-90 L-90P M-90P YLLOW P-9 R P-9R LK P-9N RN P-9V L-9R M-9R STNR LVR R UPON RQUST LVR L-9R M-9R YLLOW LK low rate (Nl/min) Ø Weight Kg orce N Part no. omposition (a) ontrol ody Tot L. / N-NO PUS-PULL(b) push-pull 0,6 6 L / push-pull 0,6 6 M-90,5 / N-NO 0,6 6 L-90 5/ 0,6 6 M-90 55,5 / N-NO not 0, 6 L-90P 7 5/ not 0, 6 M-90P,5 / N-NO LON LVR (standard red colour) 0, L-9R 5/ 0,5 M-9R 6,5 / N-NO 0, L-9R 5/ 0, M-9R 6,5 To get / NO version, supply the valve from port (b) = valves are supplied without operator Pressure 0 0 bar for all part numbers (a) = see pages _ Overall dimensions include operator _6
15 L/M / - / UNVRSL distributors UNVR ROUP / Manually operated velves L-90 M-90 M-90 R P-95R M-95 M-90 R P-96R L-9 M-9 SORT LVR YLLOW P-9 R P-9R LK P-9N L- M- L- M- LON LVR R P-9R M-9 M-9 M-9 M-9 M-95 M-95 low rate (Nl/min) Ø Weight Kg orce N Part no. omposition (a) ontrol ody Tot L. ROTTN LVR (SLTOR UPON RQUST) / N-NO rotating 0,5 9 L-90 5/ rotating 90 0,7 9 M-90 0,5 5/ c.c. rotating 0,7 9 M-90 0,5 5/ o.c. rotating 0,6 9 M-95 0,5 5/ p.c. rotating 0,6 9 M-90 0,5 / N-NO 5/ / N-NO 5/ / N-NO 5/ 90 LVR - POSTON (b) 0, 0, 0, 0, 0, 0,,7,5,7,5,6 5,,6 5, 0 0 L-9 M-9 L-9 M-9 L-9 M-9 99,5 7,5 0,5 0,5 Spool system valves 5/ c.c. 0, 0,,6 5, 6,7 M-9 M-9 5/ o.c. 0, 0,,6 5, 6,7 M-9 M-9 5/ p.c. 0, 0,,6 5, 6,7 M-95 M-95 o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port (b) = valves are supplied without operator Pressure 0 0 bar for all part numbers (a) = see pages _ Overall dimensions include operator _7
16 L/M / - / UNVRSL distributors omposition ontrol ody / - / PUS-PULL UNVR ROUP / / 5 5,5 5, 6,5 MX M6X,5 6 / UTTON / - / MNL SPRN / N-NO / - / / - / LON/SORT LVR / /,5 5,5 / - / / POSTON Short Long / 56 / - / ROTTN LVR,5 / 5 / - / SLTOR 6 >> N >> NO =Supply port = xhaust = Use = Use = xhaust = Supply port = ontrol = ontrol 0 = 0 = 7,5 5 6,5 60 5,5 6 / / 5/ - 5/ / - / / / L / /,5 5,5 OTTOM PLT WTOUT SPRN / - / / / 0,5 / - / PNUMT NOT MPL >> / / / 9 9 / - / 90 LVR 9 9 M6X,5 MX, ,5 =Supply port - = Use - 5 = xhaust = ontrol = / / 5 6,5 6 5, ,5 / / >> / Short Long / / M6X,5 MX,5,5 9 5 _
17 L/M / - / UNVRSL distributors UNVR ROUP / Valves with control L-00 L-0 L-00 M-500 M-500 L-0 L- L- M-50 M-50 M-55 M-5 M-5 M-590 ontrol Pressure bar low rate (Nl/min) Ø Weight Kg Times (ms) n. e-en. Part no. omposition (a) ontrol ody Tot L. / N SNL MPULS, 0 0,0 L-00 / NO, 0 0,0 L-0 / N-NO 5/ / N-NO OUL MPULS non mechanical mechanical not not,5 0, ,7 0,7 0 0, 0,0 0,9 0,6 0,5 0, L-00 M-500 M-500 L-0 L- L ,5 97,5 95 9,5 Spool system valves 5/ non not not, , 0,9 0, M-50 M-5 M-5,5 09 5/ c.c.,5 0 0, M-50 5/ o.c.,5 0 0, M-55 5/ p.c.,5 0 o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port 0, M-590 (a) = see page 9
18 L/M / - / UNVRSL distributors UNVR ROUP / Valves with control L-900 L-90 L-900 M-9500 M-9500 L-90 L-9 L-9 M-950 M-950 M-955 M-95 M-95 M-9590 ontrol Pressure bar low rate (Nl/min) Ø Weight Kg Times (ms) n. e-en. Part no. omposition (a) ontrol ody Tot L. / N SNL MPULS 0 0, 6 L / NO 0 0, 6 L-90 0 / N-NO mechanical 0 0, 0 9 L-900 5/ mechanical 0 0 0,6 0,7 6 0 M-9500 M ,5,5 OUL 0 0, L-90 7 / N-NO not,5 0 0, 0 L-9 0 not not,5 0 0, 0 0 L-9 9 5/ not not not,5 0, 0, 0 0, 0,5 0, M-950 M-95 M-95,5 0,5 9 5/ c.c., 0 0,0 0 M-950,5 5/ o.c., 0 0,0 0 M-955,5 5/ p.c., 0 0,0 0 M-9590,5 o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port (a) = see page 0
19 L/M / - / UNVRSL distributors UNVR ROUP / Valves with electric control L-00 L-0 L-0 L-0 M-600 M-60 L-0 L- L- M-60 M-6 M-6 M-60 M-65 M lectropilots are supplied without coil, connector and locking ring - or technical details about coils see section ccessories > oils ontrol Pressure bar low rate (Nl/min) Ø Weight Kg Times (ms) n. e-en. Part no. omposition (a) ontrol ody Tot L. / N SNL MPULS mechanical, 0,5 0 0,0 0, 0 9 L-00 L-0 0,5 5 / NO mechanical, 0,5 0 0,0 0, 0 9 L-0 L-0 0,5 5 5/ / N-NO OUL MPULS mechanical not, ,7 0,5 0 0, 0,5 0, 0, 0, M-600 M-60 L-0 L- L ,5,5,5 55,5 Spool system valves 5/ not, 0 0, 0 0, 0, 0, M-60 M-6 M / c.c.,5 0 0, M / o.c.,5 0 0, M / p.c.,5 0 0, M o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port (a) = see page
20 L/M / - / UNVRSL distributors UNVR ROUP / Valves with electric control L-900 L-90 L-90 L-90 M-9600 M-960 L-90 L-9 L-9 M-960 M-96 M-96 M-960 M-965 M lectropilots are supplied without coil, connector and locking ring - or technical details about coils see section ccessories > oils ontrol Pressione bar Portata (Nl/min) Ø Weight Kg Times (ms) n. e-en. Part no. omposition (a) ontrol ody Tot L. / N SNL MPULS mechanical 0 0 0,7 0, 5 L-900 L / NO mechanical 0 0 0,7 0, 5 L-90 L / / N_NO OUL MPULS mechanical elettrico not 0 0 0, ,0 0, 0,9 0,0 0,6 5 M-9600 M-960 L-90 L-9 L-9 7 9,5 75 5/ elettrico not,5 0, 0,5 0 0, 0, 0,9 5 0 M-960 M-96 M-96 50,5 50,5 9,5 5/ c.c., 0 0,0 0 5 M ,5 5/ o.c., 0 5/ p.c., 0 o.c. = open centres c.c. = closed centres p.c. = pressurized centres To get / NO version, supply the valve from port 0,0 0, M-965 M-9690 (a) = see pages _ 50,5 50,5 _
21 L/M / - / UNVRSL distributors omposition ontrol ody UNVR ROUP / - / MNL SPRN / - / LTR/MPL / N-NO / - / / /,5 5,5 / - / PNUMT SPRN / / 0,5 / - / PNUMT MPL / / / - / PNUMT MPL >> N >> NO = Supply port = xhaust = Use = Use = xhaust = Supply port = ontrol = ontrol 0 = 0 = 7,5 5 6,5 60 5,5 6 / / 5/ / - / / / L / / 5 / / / - / PNUMT NOT MPL >> / / / 5 / / / - / PNUMT NOT MPL >> / >> / >> / = Supply port - = Use - 5 = xhaust = ontrol = / / 6 77,5 5 6,5 6 5,5 6 / / / - / LTR MPL Spool system valves / / _
22 L/M / - / UNVRSL distributors UNVR ROUP M-5 / / 6 75, ,9x0,9x0 9 9 / / Plate for external servoassistance weight: 0,0 Kg M-55 M-55 + M-5 / / 6,7,7 95,7 6 97,7 9,5 0,5 5,5 9 05,5 5,5,9x0,9x0 9,7 9,7 option angle plate weight: 0,05 Kg M-55 M-55 + M-5 / / 0,5 0, 6,7,5 0 6,5 6,5,9x0,9x0 P option angle plate weight: 0,05 Kg _
23 L/M / - / UNVRSL distributors UNVR ROUP / Modular subbase LPS for / - 5/ - 5/ valves >> N = Supply port = Use = xhaust = ontrol 0 = >> NO = xhaust = Use = Supply port = ontrol 0 = N = Number of valve places Manual override When assembling the manifold put the sub-base on a flat surface and tighten the special screw supplied. This will give perfect alignment. P-00 P-0 P-05 N W modular sub-base with regulated and conveyed exhausts connections: / material: zamak weight: 0,6 Kg standard supplied: screws, seals, exhausts regulator and fixing coupling P-0 modular sub-base without exhaust regulator connections: / material: zamak weight: 0,6 Kg standard supplied: screws, seals and fixing coupling of valve P- inlet plate side connections connections: / material: zamak weight: 0,06 Kg standard supplied: screws and seals P- P- Spool system valves coupling connections: / material: brass weight: 0,0 Kg separatore pressioni differenziali connessione: / materiale: alluminio peso: 0,0 Kg cap for / valve mounting connections: / material: alluminium weight: 0,00 Kg adjustment screw connections: / material: brass weight: 0,006 Kg or each additional pressure, one coupling and two separators must be ordered. ap for mounting of / N-NO valves on LPS sub-base to close non-used way. Standard sub-base with adjustment screw. The screw head has a slot for screwdrivers. Upon request: adjustment screw with _5
24 L/M / - / UNVRSL distributors UNVR ROUP / Modular subbase LPS for / - 5/ - 5/ valves >> N = Supply port = Use = xhaust = ontrol 0 = >> NO = xhaust = Use = Supply port = ontrol 0 = N = Number of valve places Manual override When assembling the manifold put the sub-base on a flat surface and tighten the special screw supplied. This will give perfect alignment. P-900 P-90 P-905 N W modular sub-base regulated and conveyed exhausts connections: / material: zamak weight: 0,0 Kg modular sub-base without exhaust regulator connections: / material: zamak weight: 0,0 Kg inlet plate side connections connections: / material: zamak weight: 0,0 Kg standard supplied: screws, seals, exhaust regulator and fixing coupling standard supplied: screws, seals and fixing coupling of valve standard supplied: screws and seals P-90 P-9 P-9 P-9 coupling connections: / material: brass weight: 0,0 Kg separtor of differential pressure connections: / material: aluminium weight: 0,0 Kg cap for / valve mounting connections: / material: aluminium weight: 0,00 Kg adjustment screw connections: / material: ottone weight: 0,006 Kg or each additional pressure, one coupling and two separators must be ordered. ap for mounting of / N-NO valves on LPS sub-base to close non-used way. Standard sub-base with adjustment screw. The screw head has a slot for screwdrivers. Upon request: adjustment screw with _6
25 L/M / - / UNVRSL distributors UNVR ROUP ssembly examples Manifold pressures / / / / / / Separator of differential pressures P-/P-9 ixing coupling for valve inside the sub-base oupling P-0/P-90 Mounting of / N valve Mounting of / NO valve ixing coupling for valve inside the sub-base ap for valve mounting P-/P-9 >> N >> NO = Supply port = xhaust = Use = Use = xhaust = Supply port = ontrol = ontrol 0 = 0 = n case there should be no need to regulate exhaust, plastic insert has to be removed whilst the adjustment screw must remain in its place. Spool system valves _7
26 _
size 3 15 4200 size 4 19 6600
BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum
More information-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890
CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5
More informationISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves
BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector
More informationzamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool
P0 0mm COMPCT valves - threaded body and for sub-base mounting - Low standard power consumption (0,W): low power consumption electropilot B0 (standard version with LED) - Quick response times - High flow
More informationzamak nitrile rubber self-extinguishing technopolymes aluminum
G 0 mm - G / Valves and solenoid valves - G/ threaded valve body with traditional Univer spool system - Version with integrated connection and esternal connection - Compact design - High flow rate - Versions
More informationzamak nitrile rubber self-extinguishing technopolymer aluminum
PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to
More informationUM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
More informationSOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
More informationUM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted
U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationSPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4
SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended
More informationvalvole 16 mm ad azion. meccanico e manuale mechanically and manually actuated valves - 16 mm
mechanically and manually actuated valves - 6 mm Valvole a spola 3/2-5/2 con attacchi filettati G/8 3/2-5/2 spool valves with G/8 threaded ports Spessore della valvola: 6 mm Valve thickness: 6 mm Installazione
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationValve systems Base plates, according to standard ISO 5599-1. Brochure
ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationElectro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More information5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm
More informationSET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY 82-13-1 O-Ring (Rear) The Lead Screw Assembly is shipped separately. Note: Install Electrical and Pneumatic Circuitry. Be Sure electrical and pneumatic
More informationSeries VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25
Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More informationG1/4 Q8. Standard with biased position
Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,
More informationSECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
More informationPneumatic actuators The Original! Technics of the top class.
Automatic valves Actuators Accessories Pneumatic actuators The Original! Technics of the top class. Leaflet no. S1-01e-13 Table of contents Advantages and your benefits...page 3 Figure: actuator...page
More informationOverview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
More informationvalvole 16 mm ad azionamento pneumatico pneumatically piloted valves - 16 mm
valvole 6 mm ad azionamento pneumatico - 6 mm Valvole a spola 5/ con attacchi filettati G/8 (scarichi M5) 5/ spool valves with G/8 threaded ports (M5 exhaust ports) Spessore della valvola: 6 mm Valve thickness:
More informationSpecifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
More informationLSB Series. Valve Position Monitor. www.powergenex.com. All innovation on driving your valve automation
LS Series Valve Position Monitor ll innovation on driving your valve automation www.powergenex.com LS-1000 Series Valve Position Monitor Robust valve position monitor with a good recognizable beacon, various
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationValves. Sub-Base Mounted Valves to ISO 5599/2
Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great
More informationLinear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors
20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical
More informationGROENEVELD AUTOMATIC GREASING SYSTEMS
GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991
More informationInstallation Instructions 4662.003
Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please
More informationBETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS
BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS PART NUMBER: 132581 REVISION: A RELEASE DATE: 24 March 2000 Page 1 of 10
More informationAdams. Spray Lubrication
61 S pray lubrication is a means of lubricating moving machine parts using atomised oil or grease. stream of compressed air delivers a metered quantity of the required lubricant to the point of application.
More informationWater Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationHigh Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override
Double 3/2 N.C. solenoid valve with manual override General The high pressure/high flow capacity solenoid valve, as not available on the market, was especially engineered by BIFFI in the early '70s for
More informationManual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationRefrigeration and air conditioning Date: 10/2013
Catalogue 40 WEH Connectors for filling, evacuating and testing of refrigeration and air conditioning components Refrigeration and air conditioning Date: 10/2013 WEH - We Engineer Hightech All rights reserved,
More informationTWO HAND STATION JSTD25
TWO HN STTION JST25 JST25 JST25 JST25 JST25E JST25 F or H JST25G, example of customizing JST25P1 shown with holder 20081027 TEKNT.O Technical data JST25 Manufacturer JOK SFETY, Sweden Ordering data 2000750
More informationFITTINGS 5-01. 82A series Aluminium (light weight) compression fittings Ø 6... 42 mm tube size, BSPP and BSPT thread
FITTINS 82 series luminium (light weight) compression fittings Ø 6... 42 mm tube size, SPP and SPT thread 82 series rass compression fittings Ø 6... 42 mm tube size, SPP and SPT thread 83 series luminium
More information97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
More informationMAC-821SC-E. Centralized On-Off Remote Controller INSTALLATIONSMANUAL INSTALLATIONSMANUAL. English. Deutsch. Français. Nederlands. Español.
entralized On-Off Remote ontroller M-821S-E [FOR INSTLLER] INSTLLTION MNUL [FÜR INSTLLTEURE] INSTLLTIONSHNDBUH [POUR L INSTLLTEUR] MNUEL D INSTLLTION [VOOR DE INSTLLTEUR] INSTLLTIEHNDLEIDING [PR EL INSTLDOR]
More informationGRUPPI TRATTAMENTO ARIA FRL GROUPS
5 GRUPPI TRTTMENTO RI FRL GROUPS GRUPPO LFMTIC GRUPPI TRTTMENTO RI serie XR-S FRL GROUPS series XR-S I gruppi trattamento aria onesi Pneumatik sono dispositivi atti alla preparazione dell aria compressa,
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationM A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
More informationcompressed air conditioning accessories. one stop shop process reliable efficient economical high degree of reusability
Screwdriving technology Automation Air motors Air tools compressed air conditioning and accessories one stop shop process reliable efficient economical high degree of reusability DEPRAG offers a comprehensive
More informationPOWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2
POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long
More information2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationSINGLE LINE CRENTRALIZED LUBRICATION SYSTEM
SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM Volumetric SYSTEM 1 Ph +39 0331 601697 Fax +39 0331 365149 - www.ilclube.com - info@ilclube.it VOLUMETRIC SYSTEM INDEX INTRODUCTION 4-5 MANUAL PUMPS PRD-13 6-7
More informationSolenoid Valve Type 3962
Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling
More informationDirect Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
More informationMANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
More information2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double
4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor
More informationREGULATORS TECHNICAL DATA COMPONENTS
RUTORS ach system served by the air supply mains (e.g. actuators and general appliances) requires its own constant operating pressure. t is necessary to use a regulator to regulate the pressure within
More informationMicro oil-mist lubricator, Series NL2-LBM G 1/4
Version Micro oil-mist lubricator, an be assembled into blocks Mounting orientation vertical Working pressure min./max. 0.5 bar / 6 bar Medium ompressed air Neutral gases Medium temperature min./max. -0
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationRichter Twin Piston Quarter-turn Actuators
Richter Twin Piston Quarter-turn ctuators R ompact Powerful Maintenance-free R ouble-acting quarter-turn actuators The actuators are the optimum automation units in technical and commercial terms for Richter
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationAUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS
01B101-GB AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS MAIN FEATURES ADVANTAGE OF BUILT-IN MANUAL DISCHARGE - Provision for controlling operation of the automatic discharge
More information3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
More informationSeries. Catalogue. www.eao.com
Series 45 Catalogue www.eao.com Expert manufacturers. EAO creates possibilities. Since 1947. Founding year: 1947 Number of employees: 600 Headquarters: Olten, Switzerland Manufacturing Companies: Switzerland,
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationOperating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More information2.2 2.2. Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. For detailed information refer to chapter 2.9.
2.2 Seite 25 page oldal 25 2.2 Kapcsolótáblába építhető szelepek Valves for Panel Mounting Selected models are available for explosion hazardous environment. They are ATEX-Ex certified. For detailed information
More informationVW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS
VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS Tools required: 10mm/13mm socket and 3/8 drive ratchet with extension Torx T20/25/30 screwdrivers or bits Phillips head screwdriver,
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More information0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3
Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00
More informationModel No: VS4815 1. SAFETY INSTRUCTIONS VS4800 2. INTRODUCTION & APPLICATIONS VS4815 3. CONTENTS. 2.1 Introduction. 2.
Instructions for: Petrol Engine Twin Camshaft Setting / Locking Tool Kit - (incorporating Vanos Alignment) - BMW N42 & N46 Engines Model No: VS4800 Associated kit: Camshaft/Carrier Bracket Remover & Installer
More informationMVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)
MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types) Selection, pplication and Maintenance Valve Numbers MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801
More informationLimit Switches/ Receptacle Assembly... For Nuclear Environments
180-302/402 Series Inside ontainment reas TM Limit Switches/ Receptacle ssembly... or Nuclear nvironments eatures: Qualified to I s 344-1975, 323-1974, and 382-1972. Manufactured to a quality assurance
More informationPrecision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationOn-off valves MS-EM/EE, MS series, NPT
On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12
More information