5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)"

Transcription

1 For details about certified products conforming to international standards, visit us at 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Plug-in VFS0 VFS0 VFS0 VFS40 VFS50 Model Non plug-in VFS0 VFS0 VFS0 VFS40 VFS50 Compact yet provides a large flow capacity /8: C: 6.8 dm /(s bar) Low power consumption:.8 W DC JIS position position Single Closed center Port size Rc C [dm /(s bar)] Standard Specifications Option Specifications Manifold Flow characteristics 4/ (P A/B) 4/ 5/ (A/B R/R) b C [dm /(s bar)] or less 5 or less 40 or less 40 or less 40 or less Note ) Based on JIS B 875 (once per 0 days) for the minimum operating frequency. Note ) In the case of grommet type. Note ) Based on JIS B (The value at supply pressure 0.5 MPa.) Note 4) Factors of Note) and Note ) are achieved in controlled clean air. Double VFS0- E-0 VFS0- T-0 Exhaust center Pressure center VFS0- E-0-F VFS0- G-0 Valve specifications Electricity specifications Cv Fluid Maximum operating pressure Minimun operating pressure Proof pressure Ambient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage Allowable voltage fluctuation Coil insulation type Apparent power Inrush (Power consumption) AC Holding Power consumption Electrical entry b Cv Air/Inert gas.0 MPa 0. MPa.5 MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 50/50 m/s () Dustproof (Degrees of protection 0) (4) 00, 00 VAC, 50/60 Hz; 4 VDC 5 to +0% of rated voltage Class B or equivalent (0 C) (5) 5.6 VA/50 Hz, 5.0 VA/60 Hz.4 VA (. W)/50 Hz,. VA (.5 W)/60 Hz.8 W (.04 W: With light/surge voltage suppressor) Grommet, Grommet terminal, Conduit terminal, DIN terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 4) Based on JIS C 090. Note 5) Based on JIS C 400. Pilot type External pilot () Pilot valve manual override Non-locking push type (Extended), Locking type (Tool reguired) 0 to 0, 0, 40 VAC (50/60 Hz) Coil rated voltage, 00 VDC Option With light/surge voltage suppressor () Foot bracket (With screw) Part no.: VFS000-5A, VFS0 (single) only Note ) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa Body type VFS 0 VFS 0 Applicable manifold base Stacking manifold Max. operating cycle (cpm) Response time (ms) Note ) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire), not w/ indicator light. Pilot EXH Individual EXH (Valve side) Common EXH (Manifold base side) () () () Weight (kg) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-5

2 How to Order 4 VFS 0 G 0 position single position double position closed center position exhaust center Port size 0 Rc 4 0 Rc 8 Manual override Nil: Non-locking push type (Flush) Thread type Nil N Rc NPT T NPTF F G A : Non-locking push type (Extended) B : Locking type (Tool required) Option F: With foot bracket Mountable only for VFS0. 5 position pressure center Reverse pressure: Can be used by external pilot specifications. Body (Pilot exhaust) 0: Individual EXH Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor S With surge voltage suppressor Indicator light is not available for grommet type. W/ surge voltage suppressor is available for grommet type only. Electrical entry G: Grommet E: Grommet terminal T: Conduit terminal D-Y: DIN terminal 0 : Common EXH Coil rated voltage 00 VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 to 0 VAC (50/60 Hz) Manifold only 4 0 VAC (50/60 Hz) Pilot type 5 4 VDC Nil Internal pilot 6 VDC R External pilot 7 40 VAC (50/60 Hz). It will be 9 Other an individual external pilot. External pilot port: Body side. For 0 type, common external pilot (on manifold side). How to Order Pilot Valve Assembly SF4 Coil rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 to 0 VAC (50/60 Hz) 4 0 VAC, 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC, 50/60 Hz 9 Other -8-6 DZ Electrical entry, Light/Surge voltage suppressor G Grommet GS Grommet with surge voltage suppressor D DIN terminal DZ DIN terminal with light/surge voltage suppressor DO DIN terminal DOZ DIN terminal with light/surge voltage suppressor Y DIN terminal YZ DIN terminal with light/surge voltage suppressor YO DIN terminal YOZ DIN terminal with light/surge voltage suppressor T Conduit terminal TZ Conduit terminal with light/surge voltage suppressor E Grommet terminal EZ Grommet terminal with light/surge voltage suppressor Y: Conforming to DIN4650B standard DIN connector is not attached. Manual override Applicable model A side pilot operator for VFS B side pilot operator for VFS0 4 B side pilot operator for VFS 5 0 A side pilot operator for VFS B side pilot operator for VFS0 B side pilot operator for VFS Nil Non-locking push type (Flush) A Non-locking push type (Extended) B Locking type (Tool required) C Locking type (Lever) Individual pilot exhaust Common pilot exhaust

3 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Cylinder Speed Chart Body Ported Series VFS0-0 Conditions Average speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Bore size Series CJ Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM Pressure 0.5 MPa Load factor 50% Stroke 00 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS Pressure 0.5 MPa Load factor 50% Cylinder stroke 000 mm ø6 ø0 ø6 ø0 ø5 ø ø40 ø40 ø50 ø6 ø80 ø00 ø5 ø40 ø60 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Body ported Tube bore x Length Series CJ T0604 x m Series CM T075 x m VFS0-0 Speed controller AS00F-06 AS400F-0 Silencer AN00-0 Series MB Series CS T09 x m AS400F- AN0-0 Perpendicular, upward actuation Horizontal actuation VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-7

4 Construction position position double Closed center position closed center/exhaust center/pressure center Exhaust center Pressure center Component Parts No. q w e r Replacement Parts No. Description Body Spool/Sleeve End plate Piston Description Material Aluminum die-casted Stainless steel Resin Resin Material t Return spring Stainless steel y Pilot valve assembly u Detent assembly Note Platinum silver Black Part no. VFS0 VFS0 VFS0/40/50 VFS VFS Refer to How to Order Pilot Valve Assembly on page VFS000-9A -8-8

5 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Position Single Grommet: VFS0- G Grommet, Grommet terminal, Conduit terminal, DIN terminal Foot bracket (F) Part no.: VFS000-5A Manual override (Non-locking) -ø4. mounting hole 00 (Lead wire length) M5: External pilot port (For external pilot model) -ø6 mounting hole Solenoid valve VK VZ VF VFR VP4 VZS -ø4. mounting hole VFS -Rc /4, /8 -Rc /4 VS4 VQ7 EVS Grommet terminal: VFS0- E/EZ DIN terminal: VFS0- D/DZ/Y/YZ VFN With light/surge voltage suppressor (EZ) Lead wire O.D. Max. ø.5 Light Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) With light/surge voltage suppressor (DZ) Light -ø4. mounting hole Conduit terminal: VFS0- T/TZ -ø4. mounting hole Applicable heavy-duty cord O.D. ø6 to ø8 With light/surge voltage suppressor (TZ) Light ( ): Y, YZ -ø4. mounting hole -8-9

6 Position Double, Position Grommet, Grommet terminal, Conduit terminal, DIN terminal Grommet: VFS0- G, VFS0- G, VFS40- G, VFS50- G 94 ( position: 04) Manual override (Non-locking) -ø4. mounting hole M5: External pilot port (For external pilot model) 00 (Lead wire length) -ø4. mounting hole -Rc /4, /8 -Rc /4 Grommet terminal: VFS0- E/EZ VFS0- E/EZ VFS40- E/EZ VFS50- E/EZ Lead wire O.D. Max. ø.5 94 ( position: 04) DIN terminal: VFS0- D/DZ/Y/YZ VFS0- D/DZ/Y/YZ VFS40- D/DZ/Y/YZ VFS50- D/DZ/Y/YZ With light/surge voltage suppressor (EZ) Light Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) ( position: 4) With light/surge voltage suppressor (DZ) Light -ø4. mounting hole Conduit terminal: VFS0- T/TZ VFS0- T/TZ VFS40- T/TZ VFS50- T/TZ -ø4. mounting hole Applicable heavy-duty cord O.D. ø6 to ø8 ( position: 4) With light/surge voltage suppressor (TZ) ( ): Y, YZ Light -ø4. mounting hole -8-0

7 Manifold Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist. VV5FS- Part no. for mounting bolt and gasket BG-VFS00 Exploded View of Manifold Manifold block assembly VVFS000-A-0 Hexagon socket head cap screw: M4 x 5 (AXT5-7-) Specifications Port Specifications Option Manifold base type (P) Common Passage (R), 5(R) Common How to Order Manifold Base Stacking type Max. 5 stations Porting specifications: Rc Base Valve Base (P) Side: 8 (B), 4(A) Top:, 4 8 (R), 5(R) Side: 8 Blanking plate VVFS000-0A- With gasket, screw SUP block disk AXT66-0A EXH block disk AXT66-A Note) Individual SUP or EXH is possible with bottom porting of SUP or EXH. For your order, please indicate it in the manifold specification sheet. VV5FS Manifold stations 5 5 stations Thread type Nil Rc N NPT T NPTF F G P, EA, EB port size 0-Rc 8 Passage Porting specifications (P) (R), 5(R) (B), 4(A) Common Common Top Rc 8 Rc 8 Rc, Rc 4 8 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Gasket Base model Model Pilot exhaust Pilot common EXH Applicable valve model Type 0 Type 0 VFS VFS Note) Also VFS 0 is possible to manifold. In this case, it uses an individual pilot exhaust. For increasing the manifold bases, please prepare the manifold block assembly no. How to Order Manifold Assembly Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> (Manifold base) ( position single) ( position double) (Blanking plate) VV5FS VFS0-D-0 VFS0-D-0 VVFS000-0A- -8-

8 Type Manifold Grommet: G Pilot common exhaust: VV5FS-- Station -0 n-rc /4, /8 M4 x 5 Rc /8 External pilot port 6-Rc /8 4-ø7 mounting hole P = Blanking plate 4-Rc /8 Pilot EXH port: PE 00 (Lead wire length) Gasket Formula for manifold weight M = 0.84n (kg) n: Station Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ Lead wire O.D. Max. ø.5 Applicable heavy-duty cord O.D. ø6 to ø8 Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7) position (04) Double (94) Single (5) position (4) Double () Single (5) position (40) Double (0) Single (5) 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 04.5) 6-Rc /8 6-Rc /8 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 09) 6-Rc /8 4-Rc /8 Pilot EXH port: PE (With light/surge voltage suppressor: 9.5 (.5)) L (With light/surge voltage suppressor: 4) L L (With light/surge voltage suppressor: 9) (With light/surge voltage suppressor: 8.5 (0.5)) ( ): Y, YZ n: Station Formula L = x n + 5 L = x n

9 For details about certified products conforming to international standards, visit us at 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position position Type of actuation Single Double Closed center Exhaust center Pressure center Double check Compact yet provides a large flow capacity /8: C: 5.8 dm /(s bar) Low power consumption:.8 W DC Easy maintenance types of sub-plates: Plug-in and non plug-in JIS position Single Plug-in VFS00 VFS00 VFS00 VFS400 VFS500 VFS600 Model Non plug-in VFS0 VFS0 VFS0 VFS40 VFS50 VFS60 Port size Rc Flow characteristics 4/ (P A/B) 4/ 5/ (A/B R/R) C C [dm /(s bar)] b Cv [dm /(s bar)] b Cv Standard Specifications Option 0 or less 5 or less 40 or less 40 or less 40 or less 50 or less Note ) Based on JIS B 875 (once per 0 days) for the minimum operating frequency. Note ) Based on JIS B (the value at supply press. 0.5 MPa). Note ) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.0 kg and 0.7 kg respectively. Note 4) Note ) and Note ) are with controlled clean air. Double position Closed center Exhaust center Pressure center Double check Valve specifications Electricity specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure Ambient and fluid temperature Lubrication Pilot valve manual override Shock/Vibration resistance Enclosure Coil rated voltage Allowable voltage fluctuation Coil insulation type Apparent power (Power consumption) AC Power consumption DC Electrical entry Inrush Holding Air/Inert gas.0 MPa 0. MPa.5 MPa 0 to 60 C () Non-lube () Non-locking push type (Flush) 50/50 m/s () Type E: Dustproof (Level 0), Type F: Dripproof (Level ), Type D: Splashproof (Level 4) (4) 00, 00 VAC, 50/60 Hz; 4 VDC 5 to +0% of rated voltage Class B or equivalent (0 C) (5) 5.6 VA/50 Hz, 5.0 VA/60 Hz.4 VA (. W)/50 Hz,. VA (.5 W)/60 Hz.8 W (.04 W: With light/surge voltage suppressor) Conduit terminal DIN terminal, Grommet terminal Note ) Use dry air at low temperatures. Note ) Use turbine oil Class (ISO VG), if lubricated. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note 4) Based on JIS C 090. Note 5) Based on JIS C 400. Pilot type Manual override Main valve Pilot valve Coil rated voltage Porting specifications Option Note) Operating pressure: 0 to.0 MPa Pilot pressure: 0. to.0 MPa Max. operating cycle (cpm) External pilot Note) Direct manual override type Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever) 0 to 0, 0, 40 VAC (50/60 Hz), 00 VDC Bottom ported With light/surge voltage suppressor () () Response time (ms) () Weight (kg) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-5

10 Body type O: sub-plate How to Order Electrical entry F: conduit terminal Porting specifications Nil Side ported B Bottom ported Plug-in VFS 0 0 F 0 Port size Nil Without sub-plate 0 Rc 4 0 Rc 8 For bottom ported, Rc 4 is only available. Thread type Nil N T F Rc NPT NPTF G Non plug-in VFS D 0 Option Nil Z None With light/surge voltage suppressor Pilot valve Manual override Nil: Non-locking push type (Flush) position single position pressure center Electrical entry E: Grommet terminal D: DIN terminal 5 A : Non-locking push type (Extended) position double position double check 6 4 position closed center position exhaust center Reverse pressure: Can be used by external pilot specifications. Body type : sub-plate Pilot type Nil R Coil rated voltage VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 to 0 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 VDC VDC 40 VAC, 50/60 Hz Other Internal pilot External pilot B : Locking type (Tool required) C : Locking type (Lever) Body Option 0 Standard Direct manual override How to Order Pilot Valve Assembly SF4 Coil rated voltage F 0 Rated voltage Manual override 00 VAC, 50/60 Hz Nil 00 VAC, 50/60 Hz 0 to 0 VAC, 50/60 Hz 4 A 0 VAC, 50/60 Hz 5 4 VDC 6 B VDC C Refer to page -8-5 for voltage conversion VAC, 50/60 Hz 9 Other Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Locking type (Lever) -8-54

11 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Cylinder Speed Chart System A B System A B System Components Solenoid valve Series VFS000 Rc 4 Series VFS000 Rc 8 Speed controller AS (S = 4 mm ) AS40-0 (S = 7 mm ) Double Check Spacer/Specifications Specifications Can hold an intermediate cylinder position for an extended time If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Double check spacer Average speed (mm/s) Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS Pressure 0.5 MPa Load factor 50% Cylinder stroke 000 mm ø40 ø50 ø6 ø80 ø00 ø5 ø40 ø60 ø80 ø00 Silencer SGP (Steel pipe) Port size x Length AN00-0 (S = 5 mm ) 6A x m AN00-0 (S = 60 mm ) 0A x m Double check spacer part no. Applicable valve model Leakage (cm /min) VVFS000-A- VFS400- F Solenoid one side energized Solenoid P both sides de-energized A B Supply pressure: 0.5 MPa VVFS000-A- VFS40- D VFS40- E Caution In the case of position double check valve (VFS6 0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position. Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. P EA 0 EB or less EA 0 EB or less EA 0 EB Perpendicular, upward actuation Horizontal actuation It is when the cylinder is extending that is meterout controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load weight x 9.8)/Theoretical force) x 00% Check Valve Operation SUP side pressure P (MPa) Piston Cylinder side pressure (P) Operating range The combination of VFS 0, VFS 0 and double check spacer can be used as prevention for falling at the stroke end but cannot hold the intermediate position of the cylinder. 0 Check valve SUP side pressure (P) Cylinder side pressure P (MPa) 0 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-55

12 Construction position single position double position closed center/exhaust center/pressure center Closed center Exhaust center Pressure center Component Parts No. Description q Body w Sub-plate e Spool/Sleeve r Adapter plate t End plate y Piston u Junction cover i Light cover Material Aluminum die-casted Aluminum die-casted Stainless steel Resin Resin Resin Resin Resin Note Platinum silver Platinum silver Black Black Sub-plate Part No. 0 Plug-in VFS000-P- 0 0 Non plug-in VFS000-S- 0 Mounting bolt and gasket are not included. Part no. for mounting bolt and gasket BG-VFS000 Replacement Parts No. Description Material Part no. VFS VFS VFS /4 /5 o!0 Return spring Gasket Stainless steel NBR VFS VFS000-0 VFS000-0 VFS VFS000-0! Hexagon socket head screw Steel M x M x M x! Detent assembly VFS000-9A! Pilot valve assembly Refer to How to Order Pilot Valve Assembly on page

13 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Plug-in position single, position closed center/exhaust center/pressure center/double check position single: VFS00- F -ø5.6 mounting hole Rc /8 external pilot port (Only for external pilot) (B), 4(A) port Rc 8 (PE port) VK VZ Pilot valve manual override G / electrical entry position double: VFS00- F position closed center: VFS00- F position exhaust center: VFS400- F position pressure center: VFS500- F -ø5.6 mounting hole With direct manual override 5-Rc 4, ( position: 75) Light window At Fz 5-Rc 4 Bottom ported position double check: VFS600- F -ø5.6 mounting hole -ø5.6 mounting hole ( ): Rc 4 VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Pilot valve manual override 86.5 ( position: 96.5) Light window At Fz With direct manual override Pilot valve manual override G / electrical entry G / electrical entry 5-Rc 4, 8 5-Rc 4, 8 Light window At Fz With direct manual override ( ): Rc 4 ( ): Rc

14 Non Plug-in Position single/double, position closed center/exhaust center/pressure center/double check position single: VFS0- E, VFS0- D -ø5.6 mounting hole Rc /8 external pilot port (Only for external pilot) (B), 4(A) port Rc 8 (PE port) Cable ø8 to ø0 Pilot valve manual override Light window At DZ, EZ -ø5.6 mounting hole With direct manual override 5-Rc 4 Bottom ported 5-Rc 4, 8 ( ): Rc 4 position double: VFS0- E, VFS0- D position closed center: VFS0- E, VFS0- D position exhaust center: VFS40- E, VFS40- D position pressure center: VFS50- E, VFS50- D position double check: VFS60- E, VFS60- D -ø5.6 mounting hole -ø5.6 mounting hole Applicable heavy-duty cord O.D. ø8 to ø0 Pilot valve manual override Light window at DZ, EZ Applicable heavy-duty cord O.D. ø8 to ø0 Pilot valve manual override With direct manual override 65 ( position: 75) Light window At DZ, EZ With direct manual override 5-Rc 4, 8 5-Rc, 4 8 ( ): Rc 4 ( ): Rc

15 Manifold Specifications Plug-in Type: With Terminal Block Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block. Master connection of power and solenoid valves. Quick wiring permits easier installation. Wide range of interchangeability (MIL Spec DIN connector terminal 5 pcs attached.) Quick wiring permits easier installation. VV5FS 0T Manifold with terminal block 0 stations VV5FS D U D U 0 0C 0 stations Plug-in Type: With Multi-connector (Wiring specifications: Refer to page -8-8.) D Manifold Connector mounting with multi-connector Plug-in Type: With D-sub Connector Terminal block Multi-connector D-sub connector Plug assembly (Option) Refer to page VV5FS Manifold with D-sub connector Plug assembly (Option) Refer to page direction mounting mounting 0 stations 0F mounting mounting Thread type Port size P, EA, EB A, B Nil N Rc NPT 0 Rc 4 T Rc NPTF 0 Rc 8 F G M Mixed Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom stations Max. 8 stations (Wiring specifications: Refer to page -8-8.) D Connector mounting direction 0 stations 08 8 stations Max. 8 stations Thread type Port size Nil Rc P, EA, EB A, B N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom Thread type Port size Nil Rc P, EA, EB A, B N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Non Plug-in Type: Grommet Terminal, DIN Terminal Wiring for every valve. Grommet terminal DIN terminal VV5FS Manifold stations 0 stations 05 0 Thread type Port size Nil Rc P, EA, EB A, B N NPT 0 Rc T NPTF 0 Rc Rc 8 F G M Mixed Passage Porting specifications P EA, EB (A, B) Side Common Common Bottom -8-59

16 How to Order Manifold Assembly Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block: 6 stations (Manifold base) VV5FS-0T-06-0 ( position single) VFS00-5FZ ( position double) VFS00-5FZ (Blanking plate) VVFS000-0A <Example> : 6 stations (Manifold base) VV5FS ( position single) VFS0-5D 5 ( position exhaust center) VFS40-5D (Individual EXH spacer) VVFS000-R-0- Manifold Option Parts Assembly Individual SUP spacer An individual SUP spacer set on manifold block can form SUP port for every valve. Body type Part no. VVFS000-P-0- VVFS000-P-0- Manifold Specifications Base model VV5FS-0 VV5FS-0 Wiring With terminal block With multi-connector With D-sub connector DIN terminal Grommet terminal Flow Characteristics at the Number of Manifold (Operated individually) Model VV5FS Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust. Porting specifications A, B port Side/ Bottom Port size Rc P, EA, EB A, B () () 4, 8 to 0 Note ) Appropriate silencer for EA, EB port: AN40-04 (O.D. ø7). Note ) With multi-connector, or with D-sub connector: 8 stations max. Port size: Rc /8 Body type Part no. Passage/ 4/ (P A/B) 4/ 5/ (A/B R/R) VVFS000-0A- C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv VVFS000-0A- Applicable valve model VFS 00- F VFS 0- D VFS 0- E Station Station 5 Station Manifold Option With exhaust cleaner /Non Valve exhaust noise dampening: 5 db or more. Oil mist collection: Rate of collection 99.9% or more. Piping process reduced. Individual EXH spacer An individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type) Body type Part no. Body type Part no. VVFS000-R-0- SUP block disk EXH block disk VVFS000-R-0- When supplying manifold with more than two different pressures, high and low, insert a block disk in between stations subjected to different pressures. AXT66-A When valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block disk between stations to separate valve exhaust. Body type Part no. AXT66-A Double check spacer If the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. Body type Part no. VVFS000-A- VVFS000-A- Interface regulator Interface regulator set on manifold block can regulate the pressure to each valve. (Refer to page -8-6 for Flow Characteristics.) Body type P port regulation A port regulation B port regulation ARBF P- ARBF A- ARBF B- ARBF P- ARBF A- ARBF B- For details, refer to page With control unit /Non Filter, regulation valve, pressure switch and air release valve are all combined to form one unit. Piping processes are eliminated. For details, refer to page With serial interface unit for serial transmission Solenoid valve wiring process reduced considerably. Disperse installation possible. Manifold solenoid valve: 8 stations max. positions (5 solenoids). Maintenance and inspection are easy Blanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Body type Part no. VVFS000-0A For details, refer to Serial Transmission catalog separately.

17 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Manifold, (With terminal block): VV5FS-0T- Station - Port size n-rc 4, 8 Bottom ported: VV5FS-0T- Station - Port size Formula for manifold weight M = 0.405n (kg) n: Station -Rc 8 (Pilot EXH port: PE) : VV5FS-0- Station - Port size -G /4 Electrical entry n-rc 4, 8 Pilot valve manual override Light window -Rc 8 (External pilot port) VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN n-rc 4, 8 Pilot valve manual override n-rc 4, 8 Light window Bottom ported: VV5FS-0- Station - Port size Applicable cabtire cable O.D. ø8 to ø0 -Rc 8 (Pilot EXH port: PE) -Rc 8 (External pilot port) 6-Rc L Formula for manifold weight M = 0.09n (kg) L L n: Formula L = x n + 6 L = x n

18 Manifold with multi-connector/d-sub connector with multi-connector: VV5FS-0CD- Station - Port size, VV5FS-0CU- Station - Port size Pilot valve manual override n-rc 4, 8 Bottom ported: VV5FS-0 - Station - Port size CD CU Plug assembly VVFS000-0A- (Option: Refer to page -8-8.) Light window n-rc 4, 8 -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port) 6-Rc / Formula for manifold weight M = 0.4n (kg) n: Station Wiring specifications: Refer to page with D-sub connector: VV5FS-0FD- Station - Port size, VV5FS-0FU- Station - Port size n-rc 4, 8 Pilot valve manual override n-rc 4, 8 Light window Bottom ported: FD VV5FS-0 - Station - Port size FU Formula for manifold weight M = 0.4n (kg) n: Station Wiring specifications: Refer to page Plug assembly VVZS000-A- (Option: Refer to page -8-8.) -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port) L L L n: Formula L = x n + 6 L = x n Rc / -8-6

19 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Manifold with Exhaust Cleaner Serves to protect working environment. Valve exhaust noise dampening: 5 db or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced. Exhaust cleaner AMC60-0 (Option) Exhaust cleaner AMC60-0 (Option) Manifold Specifications Wiring Manifold : VV5FS-0 With terminal blocks With multi-connector With D-sub connector : VV5FS-0 DIN terminal Grommet terminal Applicable valve model VFS 00- F VFS 0- D, VFS 0- E Common SUP, Common EXH Porting specifications (B), 4(A) port Rc /4, /8 Rc (P), (R), 5(R) port P: Rc /, EXH: Rc to 0 () Applicable exhaust cleaners AMC60-0 (Connecting port size R ) () Note ) With multi-connector, or with D-sub connector: 8 stations max. Note ) Exhaust cleaner AMC60-0 is not attached. VV5FS Manifold Base type/electrical entry 0T 0C 0F 0 with terminal block with multi-connector with D-sub connector Connector mounting direction With connector Applicable base Nil D U None mounting mounting CD 0T, 0 0C, 0F 0 stations 0 0 stations Base type 0T, 0: -0 stations Base type 0C, 0F: -8 stations How to Order Nil N T F Port size Exhaust cleaner mounting direction Exhaust cleaner mounting direction CD CU Thread type Rc NPT NPTF G P A, B 0 Rc 4 Rc 0 Rc 8 M Mixed Passage Porting specifications P R, R (A, B) Side Common Common Bottom mounting mounting VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Caution When using an exhaust cleaner, mount it downwards. For details about exhaust cleaners, refer to Best Pneumatic Vol. 5. Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block (6 stations) (Manifold base) VV5FS-0T-06-0-CD ( position single) VFS00-5FZ ( position double) VFS00-5FZ (Blanking plate) VVFS000-0A (Exhaust cleaner) AMC60-0 (6 stations) (Manifold base) VV5FS CU ( position single) VFS0-5E ( position double) VFS0-5E (Blanking plate) VVFS000-0A (Exhaust cleaner) AMC

20 Manifold with Exhaust Cleaner : VV5FS-0T- Station - Port size - CD CU, Pilot valve manual override Light n-rc 4, 8 Pilot valve manual override Exhaust cleaner (Option) 5 -Rc /8 (Pilot EXH port: PE) -G /4 Electrical entry -Rc /8 (External pilot port: X) 6-Rc / mounting mounting : VV5FS-0- Station - Port size - CD CU n-rc 4, 8 Pilot valve manual override Light 5 Exhaust cleaner (Option) -Rc /8 (Pilot EXH port: PE) -Rc /8 (External pilot port: X) 6-Rc / mounting mounting L L L n: Formula L = x n + 6 L = x n

21 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Manifold with Control Unit Control unit (Filter, Regulator, Pressure switch, Air release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments. Piping processes are eliminated. Manifold Specifications Manifold : VV5FS-0 : VV5FS-0 With terminal block DIN terminal Wiring With multi-connector Grommet terminal With D-sub connector Applicable valve model VFS 00- F VFS 0- D, VFS 0- E Common SUP, Common EXH Porting specifications (B), 4(A) port Rc /4, /8 Rc (P), (R), 5(R) port Rc / to 0 With multi-connector, or with D-sub connector: 8 stations max. Control Unit Specifications Air filter (With auto-drain/with manual drain) Filtration degree 5 µm Regulator Set pressure (Outlet pressure) 0.05 to 0.85 MPa Pressure switch () Set pressure range: OFF 0. to 0.6 MPa Differential 0.08 MPa or less Contact a Indicator light LED (RED) Max. switch capacity VA AC, W DC 4 VAC/DC or less: 50 ma Max. operating current 00 VAC/DC: 0 ma Air release valve (Single only) Operating pressure range 0. to.0 MPa VV5FS AP Manifold Base type/electrical entry 0T with terminal block 0C with multi-connector 0F with D-sub connector 0 Connector mounting direction With connector Applicable base Nil None 0T, 0 D mounting 0C, 0F U mounting 0 stations Passage 0 0 stations P EA, EB Base type 0T, 0: to 0 stations Common Common Base type 0C, 0F: to 8 stations Port size P, EA, EB 0 Rc 0 M Caution When using an air filter with auto-drain or manual drain, mount the filter vertically. Porting specifications (A, B) Side Bottom How to Order A, B Thread type Rc 4 Rc Nil Rc 8 N Mixed NPT NPTF G T F Control Unit/Option Air release () valve spacer Pressure () switch Blanking plate <> VVFS000-4A-R ( mounting) <> VVFS000-4A-R ( mounting) Filter regulator Pressure switch Release valve IS000P-- MP- MP- VVFS000-4A-0 Filter element INA B Note ) Voltage: 4 VDC to 00 VAC Inner voltage drop: 4 V Note ) Combination of valve VFS (single) and a release valve spacer can be used an air release valve. Note ) The non plug-in type cannot be mounted afterwards. Air release valve coil rating Nil None (F, G type only) VAC, 50/60 Hz 4 VDC Other Control unit type Control equipment Nil A AP M MP F G C E Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blanking plate (Air release valve) Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) Please indicate manifold base type, corresponding valve, and option parts. <Example> with terminal block In order to mount control unit, it requires stations. (Manifold base) ( position single) ( position double) <Example> VV5FS-0T-08-0-AP5 VFS00-5FZ VFS00-5FZ 4 In order to mount control unit, it requires stations. (Manifold base) ( position single) VV5FS A VFS0-5D 4 VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN -8-65

22 Manifold with Control, : VV5FS-0T- Station - Port size -AP Voltage for release valve n-rc 4, 8 Pilot valve manual override Example for manifold Individual EXH spacer (VVFS000-R-0-) Double check spacer (VVS000-A-) Individual SUP spacer (VVFS000-P-0-) 08 Light Pressure switch Air release valve (95: -MP) Rc / (Po port) -Rc /8 (External pilot port: X) Air release valve Air filter regulator Pressure switch Outlet for check Control unit -Rc 8 (Pilot EXH port: PE) 9 -G 4 Electrical entry : VV5FS-0- Station - Port size -AP Voltage for release valve Pilot valve manual override n-rc 4, 8 Example for manifold (B) 4(A) (B) 4(A) (B) 4(A) Individual EXH spacer (VVFS000-R-0-) Double check spacer (VVFS000-A-) Individual SUP spacer (VVFS000-P-0-) Pressure switch Air release valve Light Air release valve Pressure switch Outlet for check (95: -MP) Air filter regulator Control unit 08 -Rc 8 (Pilot EXH port: PE) 9 Rc / (Po port) -Rc 8 (External pilot port: X) 6-RC / L L L L (MP) L (AP) Formula L = x n + 6 L = x n L = x n L = x n

23 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Manifold Option Parts Individual SUP spacer: VVFS000-P-0- () VVFS000-P-0- (), Double check spacer: VVFS000-A- () VVFS000-A- () (57: With direct manual override) Individual SUP spacer Individual EXH spacer: VVFS000-R-0- () VVFS000-R-0- () (57: With direct manual override) Individual EXH spacer SUP/EXH block disk: AXT66-A Interface regulator/p port regulation: ARBF P- () ARBF P- () (68: With direct manual override) Interface regulator Double check spacer Interface regulator/a port regulation: ARBF A- () ARBF A- () VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Block disk mounting position (68: With direct manual override) Interface regulator Throttle valve spacer: VVFS000-0A- () VVFS000-0A- () Interface regulator/b port regulation: ARBF B- () ARBF B- () (57: With direct manual override) Throttle valve spacer (68: With direct manual override) Interface regulator -8-67

24 Manifold Base Construction, End plate () End plate () Replacement Parts No. q w e r t y u i o! Description Connection fitting A Connection fitting B Gasket Gasket O-ring O-ring O-ring Terminal assembly Junction cover assembly Rubber plug Material Steel plate Steel plate NBR NBR NBR NBR NBR For 0T For 0SU NBR Replacement Parts: Sub Assembly Part no. VVFS000-5-A VVFS VVFS VVFS x 6.6 x.6 (End plate) 0 x 6 x (Manifold block) 6. x x.6 VVFS000-6A VVFS000-4A- AZ78-A- AXT6-9 For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly!0. For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly. Note) Manifold Base/Construction: Plug-in with terminal block. No. Description Assembly part no. Component parts Applicable manifold base!0!! 0 Manifold block!0, Terminal i, Metal joint q, w, Manifold block VVFS000-A-- 0 Gasket e, r, O-ring y, u, Receptacle assembly assembly 0 VVFS000-A-- Manifold block!0, Metal joint q, w, Gasket e, r, O-ring y, u 0 End plate () VVFS000-A- End plate (D)!, Metal joint q, w, Gasket e assembly VVFS000-A- End plate (D)!, Metal joint q, w, Gasket e End plate () assembly VVFS000-A- VVFS000-A- End plate (U)!, Metal joint q, w, O-ring t, y End plate (U)!, Metal joint q, w, O-ring t, y -8-68

25 S OLENOID VALVES S ERIES NVFS.69 M O D E L NVFS000 S Y M B O L S Position Number Of Type Port Size Cv Response Solenoid Plug-In (NPTF) Factor Time (ms) Single NVFS00 /4.8 0 or less Position /8 Double NVFS00 /4.8 5 or less /8 Closed NVFS00 / or less Center /8 Exhaust NVFS400 / or less Position Center /8 Pressure NVFS500 / or less Center /8 Perfect NVFS600 /4. 50 or less (Double Check) /8. T ECHNICAL SPECIFICATIONS S T ANDARD T ECHNICAL SPECIFICATIONS O PTIONAL Fluid Air and Inert Gas Pilot Type External Pilot Type Max Operating Pressure 50 PSI (MPa) Manual Override Main Valve Direct Manual Override Type Min Operating Pressure PSI (0.5MPa) Pilot Operator Non Locking Push Type (Extended), Valve Ambient & Fluid Temperature 4~40ºF (-0~60ºC) Lock Type (Tool), Lock Type (Lever) Lubrication Not Required Voltage AC 00V50/60Hz, 00V50/60Hz Pilot Operator Manual Override Non Locking Push Type (Flush) DC 6V, 48V, 00V Protection Construction Dust Proof Porting Bottom Ported Subplate Rated AC 0VAC50/60Hz, 0V50/60Hz, 4V50/60Hz Option W/Indicator Light & Surge Voltage DC V, 4V Voltage Suppressor Allowable Voltage Range -5 ~ 0% Rated Voltage Coil Insulation Class B or Equivalent Electrical Apparent Power AC InRush 5.0VA/60Hz, 5.6VA/50Hz (Power Consumption) Holding.VA(.5W)/60Hz,.4VA(.W)/50Hz Power Consumption DC.8W Electrical Entry Plug In Conduit Terminal (Base Access) S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N

26 .70 S OLENOID VALVES S ERIES NVFS H O W T O O R D E R NVFS000 NVFS 0 F P OSITION Position Single Position Double Position Closed Center 4 Position Exhaust Center 5 Position Pressure Center 6 Position Perfect B ODY T YPE 0 Plug-In Type P ORT S IZE - Without Subplate 0T /4 NPTF 0T /8 NPTF* * Not available for Bottom Ported P ORTING - Side *B Bottom Note) */8 NPTF Only M ANUAL O PTION 0 Standard Std & Direct Manual (Special Order) P ILOT O PERATOR - Internal R External (Special Order) V OLTAGE 00VAC (Special Order) 00VAC (Special Order) 0VAC 4 0VAc 5 4VDC 6 VDC 9 Others (Special Order) E LECTRICAL E NTRY F Through Base M ANUAL O VERRIDE - Non Locking Push Type (Flush) *A Non Locking Push Type (Extended) B Lock Type (Screw Type) *C Lock Type (Lever) Note) * Special Order O PTIONS - None Z With Indicator Light and Surge Voltage Suppressor H O W T O O R D E R M ANIFOLD FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N

27 S OLENOID VALVES S ERIES NVFS.7 H O W T O O R D E R M ANIFOLD / OPTION P ARTS ASSEMBLY S EE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Soft Start-up Valve Series AV2000/3000/4000/5000

Soft Start-up Valve Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV//4/ AV Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Large effective area (mm

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W

Port Solenoid Valve. Series VQZ1000/2000/3000. Compact, High Flow. Power consumption: 0.35 W/0.9 W ort Solenoid Valve Series // Metal Seal Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series inline Manifold mounting 5 stacking sub-base non plug-in 100 Manual operator 00 Sealed solenoid enclosure Armature 55 56 57

More information

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam CAT.ES0-6 Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption ( specification). W. 8 W W 0. W.. W 6 W New VX Series VX/ / Reduced power consumption Improved corrosion

More information

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased ambient

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CAD drawing data catalog is available. VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX SOLENOID VALVES 010 SERIES Features 61 Basic Models and Configuration 62 Specifications 63 Solenoid Valve/Manifold

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4

Direct acting 2 port solenoid valve (general purpose valve) NC (normally closed) type Port size: Rc1/8, Rc1/4 Direct acting port solenoid valve (general purpose valve) Series NC (normally closed) type Port size: Rc/, Rc/ JIS symbol Common specifications Working fluid Working pressure differential range MPa Max.

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Valves

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Catalog 095 Warning, Offer of Sale! WARNING FAILURE OR IMPROPER SELECTION

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material

Max-Air Technology Inc. NAMUR SOLENOID VALVE 4 and NEMA 7. Technical Data. Material Technical Data Port connections Inlet and exhaust Outlet DIN connector (NEMA 4 Pictured) NAMUR SOLENOID VALVE NEMAs 4 and NEMA 7 1/4 NPT NAMUR interface 1/2" NPT Pressure Range: 30 to 150 PSI Flow factor:

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Section 5 ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Contents Features and Benefits............VAL-5-2 Specifications and Technical

More information

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE NFPA D03 MOUNTING INTERFACE ISO 4401-03-02-0-94 (CETOP 4.2-4-03-250) SUBPLATE MOUNTING NFPA D03 ISO 4401-03 (CETOP 03) NG6 Pressure max 4060

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

3/4/5 Port Solenoid Valves Precautions 1 Be sure to read this before handling.

3/4/5 Port Solenoid Valves Precautions 1 Be sure to read this before handling. Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,

More information

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector Series 112/212 Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

L01 Series Direct Solenoid Actuated Valves

L01 Series Direct Solenoid Actuated Valves Series Direct Solenoid ctuated Valves www.numatics.com Table of Contents L0 Series Technical and Operating Data 3 How to Order 4 Valve Dimensions 5 Manifold ssembly 6 Speed Control Kit 7 Mounting Kit 7

More information

VAL-74. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm VALVES

VAL-74. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm VALVES V40/V4 Mini ISO Star Valves 2x/2, /2 and /, Solenoid and Pilot Actuated ISO 407- / VDMA 24 6 Size 8 mm Compact design and high performance Flexible Sub-base system True multipressure system Sandwich regulators

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 NC OUT IN 2/2 Series 110 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

V50... V53 Series, 3/2, 5/2 or 5/3 Solenoid actuated and pilot operated spool valve

V50... V53 Series, 3/2, 5/2 or 5/3 Solenoid actuated and pilot operated spool valve 50... 5 eries, /2, 5/2 or 5/ olenoid actuated and pilot operated spool valve > > ort size: /8... /2 (I /) > > igh flow in-line valves > > lexible in-line and manifold mounting options > > ompact and robust

More information

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series V VEX1 SRF VCHR PVQ T High precision, low flow consumption stainless steel regulator 601 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis VP0 Way Proportional Pressure Control Valve Nominal diameter Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact

More information

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32 www.atos.com Table C06619/E Pressure relief valves type AGAM two stage, subplate mounting ISO 6264 size 10, 20 and 32 1 MODEL CODE AGAM10/11...E AGAM20/.../V AGAM are two stage pressure relief valves with

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Series ZYY/ZYX. Ejector Valve Unit. Ejector valve unit suitable for vacuum adsorption systems

Series ZYY/ZYX. Ejector Valve Unit. Ejector valve unit suitable for vacuum adsorption systems CT.E831- Ejector Valve Unit Series ZYY/ZYX Nozzle diameters ø.7, ø1. Types S: Standard type : arge flow type Ejector valve unit suitable for vacuum adsorption systems ( combination of solenoid valve for

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A609/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

60% compared to existing model)

60% compared to existing model) ort Solenoid Valve Series VQ000/000 Metal Seal ubber Seal ower saving Standard: 0. W [Option] ohs SJ 0% compared to existing model) High-pressure ( Ma, Metal seal): 0.9 W SV (educed by J SZ VF V S0700

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

VALVES. V50 to V53 Series 3/2, 5/2 and 5/3 Spool valves Solenoid actuated and air pilot operated 1/8" to 1/2"

VALVES. V50 to V53 Series 3/2, 5/2 and 5/3 Spool valves Solenoid actuated and air pilot operated 1/8 to 1/2 0 to eries /, / and / pool valves olenoid actuated and air pilot operated /8" to /" igh flow in-line valves ompact and robust design ow power energy efficient solenoids igh cycle life lexible in-line and

More information

Pressure relief valves type ARAM two stage, in line mounting - G 3/4" and G 1 1 /4" threaded ports

Pressure relief valves type ARAM two stage, in line mounting - G 3/4 and G 1 1 /4 threaded ports www.atos.com Table C04520/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

LCG Series. Specifications. Stroke length. Linear slide cylinder Double acting single rod type. Bore size: 6, 8, 12, 16, 20, 25.

LCG Series. Specifications. Stroke length. Linear slide cylinder Double acting single rod type. Bore size: 6, 8, 12, 16, 20, 25. Linear slide cylinder Double acting single rod type Bore size: 6, 8, 2, 6, 20, 25 JIS symbol Specifications Descriptions LCG Bore size mm 6 8 2 6 20 25 Actuation Working fluid Double acting Compressed

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual (I-TORK PDS Series Pneumatic Actuator) PDS-M0108/1010 74-6, Chun Ui-Dong, Won Mi-Gu, Bucheon, Kyoung Ki-Do, Korea Tel : 82-2-855-1365, 66 Fax : 82-2-855-1367 E-mail : roy75@i-tork.com

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

VALVES ISO 5599/1 SERIES SAFE AIR

VALVES ISO 5599/1 SERIES SAFE AIR Starting from a series of sturdy, reliable valves, such as those to ISO 5599/1, some special features have been added, such as the presence of a valve status diagnostic system and the creation of a double

More information

Pilot Operated Pressure Relief Valves Series R4V / R6V

Pilot Operated Pressure Relief Valves Series R4V / R6V Characteristics Series RV / R6V Pilot operated pressure relief valves series RV (DIN 230 Form D) and R6V (DIN 230 Form E) consist of a manually adjusted pilot stage and a seated type main stage. A vent

More information

V60... V63 3/2, 2 x 3/2, 5/2 and 5/3 In-line valves Solenoid and pilot actuated G1/8... G1/2

V60... V63 3/2, 2 x 3/2, 5/2 and 5/3 In-line valves Solenoid and pilot actuated G1/8... G1/2 V6... V6 /, x /, / and / n-line valves Solenoid and pilot actuated /8... / igh flow rate at small size roven sealing system, maintenance-free ifferent manual override options available ow power consumption

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 02 A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket 21 25 4 69 5 stainless

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

VAL-146. ISO Star Series Valves 5/2 and 5/3 solenoid and air pilot actuated valves. Valves. Technical Data

VAL-146. ISO Star Series Valves 5/2 and 5/3 solenoid and air pilot actuated valves. Valves. Technical Data Valves NITUFF coated non-corrosive spool and sleeve for long trouble free life (100 million plus cycles) Integral flow controls for cylinder speed control on size #1, and #2 models Low power solenoids

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series non plug-in plug-in Manifold mounting 35 non plug-in plug-in 100 Pilot air accumulator Integral ground wire Manual operator

More information

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air CAT.EUS0- A -UK Direct Operated Port Solenoid Valve For Water, Oil, Steam, Air New Series VX// Reduction of power consumption ( specification) W. W W W.. W 0. W Low power consumption type: 0. W (Held at

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

BVP70, BVPS70 & BVE70 Series

BVP70, BVPS70 & BVE70 Series BVE70 BVPS70 BVP70 BVP70, BVPS70 & BVE70 Series Pneumatically & Electrically Actuated Tube Compression End Style Valves 2 BVP70, BVPS70 & BVE70 Series Ball Valves Ball Valve - MATERIALS OF CONSTRUCTION

More information

Scavenging and Pressure Relief Valve Block SDVB

Scavenging and Pressure Relief Valve Block SDVB Brueninghaus Hydromatik Scavenging and Pressure Relief Valve Block SDVB Control Elements of the A4VSG and A2P RE 95533/03.96 RE 95533/03.96 Replaces 01.82 The scavenging and pressure relief valve block

More information

Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company

Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company E/P (Electro-Pneumatic) Pressure Control Valves Index Page Series ED02, proportional solenoid, analog

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning ilter Series Series / or Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the.r.l. combination

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, & other High Pressure Gases High Pressure Cryogenics Flammable Liquids & Gases

More information

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890 CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS.

AB/AG. General purpose direct acting 2, 3 port solenoid valve. (General purpose valve) For air, vacuum, water, oil CONTENTS. / (eneral purpose valve) eneral purpose direct acting, 3 port solenoid valve For air, vacuum, water, oil N/ US/ F/ F/ Overview The general purpose valve series enables control of various types of fluids

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/