Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

Size: px
Start display at page:

Download "0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3"

Transcription

1 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted Valve width (mm) [Option] Flow characteristics Metal seal C [dm /(s. Rubber seal bar)] C [dm /(s. bar)] 0. (Poppet) (Poppet)

2 + Metal Seal / Rubber Seal Port Solenoid Valve 00/00/00 Solenoid Valve Variations Sonic conductance C [dm /(sbar)] Type of actuation Voltage Light/Surge voltage Manual override 00 Metal Rubber (Poppet) 0. P.79 Body ported port 00 P P P Metal Rubber (Poppet).0 (R) N.C. () () (P) (R) (P) N.O. (Except 00) (Standard) VDC VDC (Option) 00 VC 00 VC 0 VC 0 VC Grommet (G) L-type plug (L) +- M-type plug (M) -+ DIN terminal (Y) With light/surge voltage L-type plug (L) M-type plug (M) DIN terminal (YZ) Except 00 Non-locking push type (Tool required) Locking type (Tool required) Base mounted port 00 P Except P

3 00/00/00 Manifold Body Ported Base model V- V- Piping specifications Piping direction Bore size (P), (R) () Top Top Rc /8 Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) C (for ø) C (for ø) M (M thread) pplicable solenoid valve P.799 pplicable stations to 0 stations to 0 stations Manifold Options Body Ported Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) P.80 Blanking plug KP- KP-0 KP-0 KP-08 KP-0 P.80 DIN rail XT00-DR- P.80 Silencer (for EXH port) 00 V- Top Rc / C (for ø) C8 (for ø8) C0 (for ø0) Rc / to 0 stations P.80 Base Mounted P.8 Base Mounted Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) P.8 Blanking plug KP- KP-0 KP-0 KP-08 KP-0 P.8 DIN rail XT00-DR- 00 Base model V- Piping direction Side/ top Piping specifications Bore size (P), (R) () Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) pplicable solenoid valve pplicable stations to 0 stations P.8 Silencer (for EXH port) V- V- Side Side Rc / (P) port Rc /8 (R) port Rc / C (for ø) C (for ø) C8 (for ø8) Rc /8 C (for ø) C8 (for ø8) C0 (for ø0) Rc / to 0 stations to 0 stations P.8 Port plug V00-CP (for 00) P.8 79

4 Body Ported Plug Lead Unit Port Solenoid Valve 00/00/00 Single Unit 00 / How to Order Valve [Option] Note) :DC type only. M C PR 00 body width 0 mm Type of actuation N.C. () (P) (R) Option : None F: With bracket Note) DC type only. Body type Bracket Function Symbol Specifications DC C Standard (0. W) Note ) Note ) K High pressure type R Note, ) External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. : Non-locking push type Port size [() port] C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting M M thread (Replaceable type) Note) For inch size One-touch fittings, refer to page 80. B: Locking type (Tool required) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC G: Grommet (DC specification) L: L-type plug with lead wire With light/ surge voltage LO: L-type plug without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage MO: M-type plug without With light/ surge voltage Note) Standard lead wire length: 00 mm Note) For applicable One-touch fitting and silencer models for this valve series, refer to page

5 Body Ported 00/00/00 00/00 / How to Order Valve Note) C-type models that Made to Order are have (For details, refer to pages 79 and 8.) DIN terminals only. [Option] 00 body width mm 00 body width 8 mm Type of actuation N.C. () N.O. N.C. N.O. (R) (P) (R) (P) (R) () () () (P) (R) (P) Metal seal Rubber seal Body type Body ported M C IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 80. Note) C-type models that are have DIN terminals only. Option : None F: With bracket Port size [() port] Symbol Port size C ø One-touch fitting C ø One-touch fitting C8 ø8 One-touch fitting C0 ø0 One-touch fitting M M thread 0 Rc / Note) For inch size One-touch fittings and option thread type, refer to page 80. : Non-locking push type B: Locking type (Tool required) (Tool required) +- Bracket Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type BR Note, ) High speed response/external pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For applicable One-touch fitting and silencer models for this valve series, refer to back page 88. (DC specification) CEcompliant CEcompliant C DC G: Grommet (DC specification) + Y: DIN terminal +- L: L-type plug with lead wire With light/ surge voltage LO: L-type plug without With light/ surge voltage YO: DIN YZ: DIN terminal terminal without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage YOS: DIN Note ) terminal without (DC specification) With surge voltage MO: M-type plug without With light/ surge voltage YS: DIN Note ) terminal With surge voltage C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. + 79

6 00/00/00 Specifications Valve construction Fluid Metal seal Rubber seal ir, Inert gas 00 (Poppet seal) Max. operating pressure (MPa) 0.7 (High pressure type:.0) (High pressure type:.0) Min. operating pressure (MPa) mbient and fluid temperature ( C) Max. operating frequency (Hz) Pilot exhaust method Lubrication to 0 (No freezing) Individual exhaust Not required 0. 0 Common exhaust Mounting orientation Impact/Vibration resistance (m/s Note ) ) Enclosure Push type, Locking type (Tool required) Free 0/0 Dustproof (DIN terminal: IP Note ) ) Based on IEC09 Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and 000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Note ) When IP compliant DIN terminals are selected: -YW- Solenoid Specifications Semi-standard Specifications High speed response type High pressure type (Metal seal type only) External pilot type For details on external pilot type, refer to page 80. Made to Order (For details, refer to page 8.) Symbol Description X0 Pilot valve common exhaust X90 Main valve fluororubber X ll fluororubber Coil rated voltage (V) llowable voltage fluctuation Standard Power High speed consumption (W) DC response, high pressure 00 V pparent power (V) C Surge voltage Indicator light DC C 0/0 Hz 0 V [ V] 00 V 0 V [0 V] Grommet (G) L-type plug (L) In common between 0 VC and VC, and between 0 VC and 0 VC. For VC and 0 VC, the allowable voltage is % to +% of rated voltage. M-type plug (M) DIN terminal (Y) G, L, M Y, 00, 0, 00, 0 ±0% of rated voltage 0. [(With light: 0. (DIN terminal with light: 0.)] 0.9 [(With light: 0.9 (DIN terminal with light:.0)] 0.78 (With light: 0.8) 0.78 (With light: 0.87) 0.8 (With light: 0.89) [0.9 (With light: 0.97)] 0.8 (With light: 0.87) [0.9 (With light:.07)].8 (With light:.). (With light:.0).0 (With light:.) [. (With light:.)].7 (With light:.) [.9 (With light:.0)] Varistor LED (Neon light when C with DIN terminal) Flow Characteristics Valve construction Model 00 N.C. valve Poppet N.C. Metal seal 00 valve Rubber seal N.O. Metal seal N.C. valve Metal seal Rubber seal 00 valve Rubber seal N.O. Metal seal valve Rubber seal (P ) Flow characteristics ( R) C [dm /(sbar)] b Cv C [dm /(sbar)] b Cv Note ) Based on JIS B (Supply pressure: 0. MPa; with light/surge voltage : clean air) Response time values will change depending on pressure and air quality. Note ) Weight for threaded connection Standard: 0. W Response time (ms) Note ) High speed response: 0.9 W High pressure: 0.9 W C 0. 0 or less or less or less 0. or less or less 8 or less or less 0. or less or less or less 0. or less or less 8 or less or less 0. or less or less or less 0. or less 7 or less or less or less 0.7 or less or less 7 or less 0.9 or less 7 or less or less or less 0.9 or less or less 7 or less Note ) Weight (g) 7 9

7 00/00/00 Construction 00 Poppet type N.C. () e w q (P) (R) Component Parts No. Description Body Spool valve Pilot valve assembly Material Resin luminum/hnbr Note r P, R port Resin/luminum 00- (Standard) 00-B (External pilot type) 00/00 Metal seal type Rubber seal type r e w q r e w q N.C. N.C. () () (R) (P) (R) (P) r e w q r e w q N.O. () (R) (P) N.O. () (R) (P) Component Parts No. Description Body Spool, Sleeve Spool valve Piston Pilot valve assembly Material Note luminum die-casted Stainless steel Metal seal luminum/hnbr Rubber seal Resin Note) For How to Order Pilot Valve ssembly, refer to page

8 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C, C-PR.8 () One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" x ø. (For mounting) pprox C: 9. N7:.9 (.)..8 With bracket Note) For bracket assembly part no., refer to page 807. Note) Tightening torque: 0. to 0. N m (X: External pilot port) <For external pilot> ø. (PE port) <For external pilot> [ (P), (R) port] R P 0 x ø. (For mounting). 7 -G-M-PR [() port] ø. (PE port) 0. Note) For One-touch fittings for P/R port and silencer part no., refer to page 88. L-type plug (L): -L-C, C, C-PR M-type plug (M): -M-C, C, C-PR pprox [0.8] pprox. 00. [7.] 9.9 [.] [.9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 79

9 + R P + Body Ported 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C x ø. (For mounting) pprox One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" M x 0. (External pilot port) <For external pilot> x ø.7 (For manifold mounting) C:.7 N7:. (.) x ø. (For mounting) x M. x 0. Thread length With bracket /8 [(P) port] G/ [(R) port] x ø. die-cast hole (For manifold gasket positioning) Note) For bracket assembly part no., refer to page 807. ø.8 (PE port) ø. (Reverse-mounting-prevention hole ( models only). -G-M [() port] Note) For One-touch fittings for P/R port and silencer part no., refer to page 88. L-type plug (L): -L-C, C DIN terminal (Y): -Y-C, C pprox [8.] 8.8 [.8] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M-C, C 0. [7.] pprox [7.]. Max. 0 pplicable cable O.D. ø. to ø Pg Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 797

10 + P R 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-C, C8, C0 pprox One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" ø0, ø/8" x ø. (For manifold mounting) x ø. (For mounting) (External pilot port) <For external pilot> (.) x ø. (For mounting) ø.8 (PE port) /8 [(R) port] x ø die-cast hole (For manifold gasket positioning) / [(P) port] 0. ø. (Reverse-mountingprevention hole ( models only). x M. x 0. Thread length -G / [() port] 8.. With bracket Note) For bracket assembly part no., refer to page 807. L-type plug (L): -L-C, C8, C0 DIN terminal (Y): -Y-C, C8, C0 pprox [88] [9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Max. 0 pplicable cable O.D. ø. to ø7 Pg M-type plug (M): -M-C, C8, C0 pprox [78.] [0.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 798

11 Body Ported Plug Lead Unit Port Solenoid Valve 00/00/00 Manifold Connector Kit 00 / How to Order Manifold [Option] Note) For models, DC type only. V Manifold type Body ported Stations 0 stations 0 0 stations C Kit type C Connector D 00 / How to Order Valve Option None D DIN rail mounting (With standard DIN rail length) D0 Note ) DIN rail mounting (Without DIN rail) R Note ) External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 80. Note ) When two or more symbols are specified, indicate them alphabetically. Note) For (P), (R) of optional thread type, refer to page 80. M 00 body width 0 mm Type of actuation N.C. Body type Function Symbol Specifications DC C Standard (0. W) Note ) K Note ) High pressure type Note, ) R External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. Non-locking push type B Locking type (Tool required) Symbol G L LO M MO C With light/surge voltage Grommet (DC specification) None L-type plug with lead wire L-type plug without Yes M-type plug with lead wire M-type plug without Note) Standard lead wire length: 00 mm Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For models, DC type only. Port size [() port] C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting M M thread (Replaceable type) Note) For inch size One-touch fittings, refer to page

12 00/00/00 00/00 / How to Order Manifold Made to Order (For details, refer to page 8.) Note) C-type models that are have DIN terminals only. [Option] V 08 C Manifold type Body ported Stations 0 stations 0 0 stations Kit type C Connector Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) Note) Order DIN rail separately. For DIN rail part no., refer to page 80. Note) For (P), (R) of optional thread type, refer to page /00 / How to Order Valve M 00 body width mm 00 body width 8 mm Type of actuation N.C. Metal seal N.O. Metal seal N.C. Rubber seal N.O. Rubber seal Body type Body ported Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type BR Note, ) High speed response/external pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 80. Note ) For C specification power consumption, refer to page 79. Caution Use standard (DC) specification for continuous duty. 800 Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Port size [() port] Symbol Port size C ø One-touch fitting C ø One-touch fitting C8 ø8 One-touch fitting C0 ø0 One-touch fitting M M thread 0 Rc / Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Y YO YZ YS YOS IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page Note) For inch size One-touch fittings and optional thread type, refer to page 80. Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire M-type plug without DIN terminal DIN terminal without DIN terminal DIN terminal (DC specification) Note) C-type models that are have DIN terminals only. Light/surge voltage None Yes None Yes Note ) Yes (Without light) Note ) DIN terminal without (DC specification) C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit.

13 Body Ported 00/00/00 Manifold Specifications Base model Piping specifications Piping Port size direction (P), (R) () pplicable Manifold pplicable solenoid base stations valve weight (g) C (for ø.) 00 V- Top Rc /8 C (for ø) C (for ø) to 0 stations M (M thread) C (for ø) 00 V- Top Rc /8 C (for ø) to 0 M (M thread) stations C (for ø) C8 (for ø8) 00 V- Top Rc / to 0 C0 (for ø0) stations Rc / stations: 8 ddition per station: 9 stations: 8 ddition per station: 0 stations: ddition per station: 7 How to Order Manifold ssembly (Example) D side Stations U side V-0C V M-C set (C kit -station manifold base part no.) set (Blanking plate assembly part no.) sets (N.C. type part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. dd the valve and option part number under the manifold base part number. When entry of part numbers becomes complicated, indicate by the manifold specification sheet. 80

14 00/00/00 Dimensions: 00 V- Stations C Grommet (G) U side D side One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" x ø. (For mounting) (8) L L L. [() port] (.) C:. N7: /8 [(P), (R) port]. () (.) P R P R () pprox. 00 (Station n) (Station ). 70. [77.] 9. [.] () (.) (DIN rail) (DIN rail clamp thread).. (Pitch) P = 0.. L (Rail mounting hole pitch:.) L () x (X: External pilot port) <For external pilot>.9 (PE: Pilot EXH port) M The dashed lines indicate the DIN rail mounting [-D]. (7.) L-type plug (L) M-type plug (M) pprox [7.] pprox [.9] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations)

15 R P Body Ported 00/00/00 Dimensions: 00 V- Stations C Grommet (G) U side One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" (8) () (.) 9. P R D side [() port] L L x ø. L. (For mounting) (0.) (For M) /8 [(P),(R) port] (0) () (DIN rail) (DIN rail clamp thread) M x 0. (External pilot port) <For external pilot>. (Pitch) P = 9 L (Rail mounting hole pitch:.) L () pprox PE port 7. (Station n) (Station ) C: 0. N7: (.) (7.) 8 ().9 The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) 79 [8.] pprox. 00 Dimensions L n L L L L L [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C [7.]. pprox [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Max. 0 Pg pplicable cable O.D. ø. to ø7 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + L = n + n: Stations (Max. 0 stations)

16 L L L (Station n) (Station ) /00/00 Dimensions: 00 V- Stations Grommet (G) U side One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" (8) ø0, ø/8" () C (.) (DIN rail) P R P R D side / [() port] x ø. (For mounting) (.) / [(P), (R) port] 0 () (DIN rail clamp thread) (External pilot port) <For external pilot> (Pitch) P = 9 L (Rail mounting hole pitch:.) L () pprox. 00 PE port. (.) (For /) (7.) () The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) 8.8 [88] pprox. 00 Dimensions L n L L L L L [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C [78.] 7 pprox [7.8] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Max Pg pplicable cable O.D. ø. to ø7 Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = 9n + L = 9n + n: Stations (Max. 0 stations)

17 Body Ported 00/00/00 Manifold Options Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Blanking plug KP- KP-0 KP-0 KP-08 KP-0 L ød Dimensions pplicable Model fitting size ød. 8 0 KP- KP-0 KP-0 KP-08 KP-0 (mm) L D DIN rail XT00-DR- L 7. s for, enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each kit. () () Each manifold can be mounted on a DIN rail. Insert D at the end of the manifold part number. The DIN rail is approximately 0 mm longer than the length of manifold. L Dimension No. L dimension No. L dimension L =.n Silencer (for manifold EXH port) Silencer is installed in the manifold EXH port. ø N0-0 N0-0 ø. Dimensions Model Silencer part no. 00 N N N0-0 For a silencer to be mounted in a single valve unit, refer to page

18 Body Ported Semi-standard Specifications [Option] External Pilot Specification The external pilot specification is used when the operating pressure is below the minimum operating pressure 0. to 0. MPa or when valve is used for a vacuum application. Order a valve by adding the external pilot specification [R] to the part number. Valve Part No. R Entry is the same as standard products. Inch Size One-touch Fittings and Optional Threads Inch size One-touch fittings and NPT, NPTF and G thread are available. Valve Part No. External pilot port M x 0. (00) (00) Entry is the same as standard products. Cylinder port Symbol N N N7 N9 N M 0 pplicable tubing O.D. (Inch) ø/8" ø/" ø/" ø/" ø/8" M thread / thread 00 () port Note) Metric size One-touch fittings (C) are also available. N7 T Pressure Specifications External pilot pressure range Note ) Metal seal Rubber seal (00: poppet) 00 Note ) 00/00 0. to 0.7 MPa 0. to 0.7 MPa 0. to 0.7 MPa Operating pressure range Note ) 00 kpa to 0.7 MPa Note ) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is MPa. Note ) Pump down from (P) port when 00 series vacuum type is specified. pply pressure from (R) port to relieve vacuum pressure. Set the release pressure at 0% of external pilot pressure or less. In addition, when the 00 is to be used at an operating pressure greater than 0. MPa, please assure that the operating pressure is set to equal to or less than the external pilot pressure. Thread type (Cylinder port and (P), (R) ports) Rc N NPT T NPTF F G Note ) (R) port of the 00 is only G/. Note ) Except 00 Manifold Part No. V C D 00T Entry is the same as standard products. IP Enclosure (Based on IEC09) Note) The pilot exhaust IP valves is common with main valve exhaust. (The standard valve has an individual exhaust for the pilot valve.) DIN terminal is available with IP enclosure. Valve Part No. (pplicable to the 00/00 rubber seal with the exception of the external pilot type) Y W 80 Entry is the same as standard products. Thread type ((P), (R) ports) Rc 00N NPT 00T NPTF 00F G

19 Body Ported Replacement Parts One-touch Fitting ssembly (for Cylinder port) Fitting size Model 00/00 00 C C C C8 C0 VV000-0-C VV000-0-C Note) Purchasing order is available in units of 0 pieces. VV000-0-C VV000--C VV000--C8 VV000--C0 M (00 only) VV000-0-M <Plug assembly> DC: SY VC: SY VC: SY Other C voltages: SY Without lead wire: SY00-0- (with and sockets only) <Gasket and screw assembly> Model Part no GS GS GS- Note) bove part number consists of 0 units. Each unit has one gasket and two screws. Purchasing Symbol Specifications DC order is available in units of 0 pieces. Standard (0. W) B Note) High speed response type <Bracket assembly> Lead wire length 00 mm mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm How to Order Include the assembly part number together with the part number for the plug s solenoid valve without. Example) In case of 000 mm of lead wire DC -LO-M-PR SY C -LO-M-PR SY Model Part no. Tightening torque (N m) Note) FB 00-FB 00-FB 0. to 0. Note) Tightening torque when mounting a bracket on the valve. <Pilot valve assembly> M V Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type (pplicable to 00/00) K Note) High pressure type (pplicable to Metal seal type, Poppet seal type) Note) Semi-standard None (pplicable to 00/00) Yes (pplicable to 00) V G <DIN terminal type (pplicable to the 00/00)> High pressure type K Note) (Metal seal type only) Note) Semi-standard Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Symbol Y YO YZ YS Note) Symbol DC C G LU LOU MU LZ LOZ MZ Valve model -L -M Function C Y Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire MOU MOZ M-type plug without Note) pilot valve electrical entry (L, M) is the opposite of the how to order of valve body. Pilot valve model VM-M VM-L (pplicable to the 00) X0 Non-locking push type Locking slotted type DIN terminal DIN terminal without DIN terminal with light/surge voltage DIN terminal with surge voltage (DC specification) DIN terminal with surge voltage, without (DC specification) Light/surge voltage None Light/surge voltage None Yes Yes YOS Note) (Without light) Note) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. Caution When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V (DIN terminal) from a V (Grommet, L-type, M-type), or vice versa. B Yes 807

20 (P) Base Mounted Plug Lead Unit Port Solenoid Valve 00/00/00 Single Unit 00 / How to Order Valve [Option] Note) For models, DC type only. M 0 00 body width 0 mm Type of actuation () N.C. (R) Body type Base mounted Function Symbol Specifications DC C Standard (0. W) Note ) K Note ) High pressure type Note, ) R External pilot type KR Note, ) High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. : Non-locking push type G: Grommet (DC specification) L: L-type plug with lead wire With light/ surge voltage Port size [() port] CP Without sub-plate 0 Rc /8 B: Locking type (Tool required) Note) For optional thread type, refer to page 8. LO: L-type plug without With light/ surge voltage Note) For models, DC type only. M: M-type plug with lead wire With light/ surge voltage MO: M-type plug without With light/ surge voltage Note) Standard lead wire length: 00 mm Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) For sub-plate part no., refer to page

21 Base Mounted 00/00/00 00/00 / How to Order Valve Made to Order (For details, refer to pages 80 and 8.) Note) C-type models that are have DIN terminals only. [Option] M 00 body width mm 00 body width 8 mm Type of actuation N.C. () N.O. N.C. N.O. (R) (R) () () (P) (R) (P) () (P) Metal seal Rubber seal IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 8. Port size [() port] Symbol Port size Without sub-plate 0 Rc /8 0 Rc / 0 Rc /8 : Non-locking B: Locking type push type (Tool required) (Tool required) Note) C-type models that are have DIN terminals only Note) For optional thread type, refer to page 8. (R) (P) Body type Body mounted Function Symbol Specifications DC C Standard (0. W) Note ) B Note ) High speed response type High pressure type K Note ) (Metal seal type only) R Note, ) External pilot type High speed response/external BR Note, ) pilot type KR Note, ) High pressure/external pilot type (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. (DC specification) CEcompliant CEcompliant C DC G: Grommet (DC specification) + Y: DIN terminal L: L-type plug with lead wire With light/ surge voltage Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC +- LO: L-type plug without With light/ surge voltage YO: DIN YZ: DIN terminal terminal without With light/ surge voltage M: M-type plug with lead wire With light/ surge voltage YOS: DIN Note ) terminal without (DC specification) With surge voltage MO: M-type plug without With light/ surge voltage YS: DIN Note ) terminal With surge voltage C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit. + Note) For sub-plate part no., refer to page

22 00/00/00 Specifications Valve construction Fluid Metal seal Rubber seal ir, Inert gas 00 (Poppet seal) Max. operating pressure (MPa) 0.7 (High pressure type:.0) (High pressure type:.0) Min. operating pressure (MPa) mbient and fluid temperature ( C) Max. operating frequency (Hz) Pilot exhaust method Lubrication to 0 (No freezing) Individual exhaust Not required 0. 0 Common exhaust Mounting orientation Impact/Vibration resistance (m/s ) Note ) Enclosure Push type, Locking type (Tool required) Free 0/0 Dustproof (DIN terminal: IP Note ) ) Based on IEC09 Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between and 000 Hz. Test was performed to axis and right angle directions of the main valve and armature when pilot signal is ON and OFF. (Value in the initial state) Note ) When IP compliant DIN terminals are selected: -YW-- Solenoid Specifications Semi-standard Specifications High speed response type High pressure type (Metal seal type only) External pilot type For details on external pilot type, refer to page 8. Made to Order (For details, refer to page 8.) Symbol Description X0 Pilot valve common exhaust X90 Main valve fluororubber X ll fluororubber Coil rated voltage (V) llowable voltage fluctuation Standard Power DC High speed consumption (W) response, high pressure 00 V pparent power (V) C Surge voltage Indicator light DC C 0/0 Hz 0 V [ V] 00 V 0 V [0 V] Grommet (G) L-type plug (L) In common between 0 VC and VC, and between 0 VC and 0 VC. For VC and 0 VC, the allowable voltage is % to +% of rated voltage. M-type plug (M) DIN terminal (Y) G, L, M Y, 00, 0, 00, 0 ±0% of rated voltage 0. [(With light: 0. (DIN terminal with light: 0.)] 0.9 [(With light: 0.9 (DIN terminal with light:.0)] 0.78 (With light: 0.8) 0.78 (With light: 0.87) 0.8 (With light: 0.89) [0.9 (With light: 0.97)] 0.8 (With light: 0.87) [0.9 (With light:.07)].8 (With light:.). (With light:.0).0 (With light:.) [. (With light:.)].7 (With light:.) [.9 (With light:.0)] Varistor LED (Neon light when C with DIN terminal) Flow Characteristics Valve construction Model N.C. valve Poppet N.C. Metal seal valve Rubber seal N.O. Metal seal valve Rubber seal N.C. Metal seal valve Rubber seal N.O. Metal seal valve Rubber seal (P ) Flow characteristics ( R) C [dm /(sbar)] b Cv C [dm /(sbar)] b Cv Note ) Based on JIS B (Supply pressure: 0. MPa; with light/surge voltage : clean air) Response time values will change depending on pressure and air quality. Note ) Weight without sub-plate Standard: 0. W Response time (ms) Note ) High speed response: 0.9 W High pressure: 0.9 W C 0. 0 or less or less or less 0. or less or less 8 or less or less 0.80 or less or less or less 0.9 or less or less 8 or less or less 0.7 or less or less or less 0.80 or less 7 or less or less or less.0 or less or less 7 or less 0.9 or less 7 or less or less or less. or less or less 7 or less Note ) Weight (g) 78

23 Base Mounted 00/00/00 Construction 00 Poppet type e r w q N.C. () (P) (R) Component Parts No. Description Body Spool valve Pilot valve assembly Port plug Material Resin luminum/hnbr Resin/HNBR Note V00-CP 00/00 Metal seal type Rubber seal type r e w q r e w q N.C. () N.C. () (R) (P) (R) (P) r e w q r e w q N.O. () (R) (P) N.O. () (R) (P) Component Parts No. Description Body Spool, Sleeve Spool valve Piston Pilot valve assembly Material luminum die-casted Stainless steel luminum/hnbr Resin Note Metal seal Rubber seal Note) For How to Order Pilot Valve ssembly, refer to page 8. 8

24 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G-0 (X: External pilot port) (For external pilot).. /8 [() port] pprox. 00 pprox [0.8] pprox. 00. [7.] 0.9 [.] [.9] x ø. (For mounting).. PE - + P R (PE port) /8 [(P), (R) port] L-type plug (L): -L-0 M-type plug (M): -M-0 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 8 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C

25 Base Mounted 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G- 0 0 /8, / [() port] 9. 9 x ø. (For mounting) pprox X 9.8 PE port 9 R P (External pilot port) <External pilot only> /8, / [(P), (R) port] 8 (7) 0 (0.) ( ): -G-0 L-type plug (L): -L- 0 0 DIN terminal (Y): -Y- 0 0 pprox [8.] 9.8[.8] Max pplicable cable O.D. ø. to ø7 Pg7. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M-. [8.] pprox [7.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C 8

26 00/00/00 Dimensions: 00 Single Unit Grommet (G): -G- 0 0 /, /8 [() port].. 9 x ø. (For mounting) 7 R P pprox X 7 PE port... (External pilot port) <External pilot only> /, /8 [(P), (R) port] (9) 7 () ( ): -G-0 L-type plug (L): -L- 0 0 DIN terminal (Y): -Y- 0 0 pprox [88.] 7 [] Max. 0 pplicable cable O.D. ø. to ø7 Pg7 9. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C M-type plug (M): -M [7.] pprox [78.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). 8

27 Base Mounted Plug Lead Unit Port Solenoid Valve 00/00/00 Manifold Connector Kit 00 / How to Order Manifold [Option] Note) For models, DC-type only. 00 Stations 0 stations 0 0 stations V C C C M CP CM Note ) Note ) Manifold type Base mounted ø. One-touch fitting ø One-touch fitting ø One-touch fitting M thread (Replaceable type) With port plug Mixed port sizes 08 C Port size [() port] For side ported For top ported C Note ) When CP port plug is attached on all () port. Valve on manifold is top ported. Note ) Specify the mixture port (including top and side piping) by the manifold specification sheet. Note ) For inch size One-touch fittings, refer to page 8. Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) R External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 8. Note ) When two or more symbols are specified, indicate them alphabetically. Kit type C Connector 00 / How to Order Valve M 00 body width 0 mm Type of actuation N.C. Body type Base mouned Function Symbol Specifications DC C Standard (0. W) K Note ) High pressure type Note, ) R External pilot type Note, ) KR High pressure/external pilot type Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page 80. Caution Use standard (DC) specification for continuous duty. Note ) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC C Note) For models, DC type only. Port size CP With port plug For side ported C ø. One-touch fitting C ø One-touch fitting C ø One-touch fitting For top ported M M thread Note) For inch size One-touch fittings, refer to page 8. Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Light/surge voltage Grommet (DC specification) None L-plug plug with lead wire L-plug plug without Yes M-plug plug with lead wire M-plug plug without Note) Standard lead wire length: 00 mm 8

28 00/00/00 00/00 / How to Order Manifold Made to Order (For details, refer to page 8.) Note) C-type models that are have DIN terminals only. [Option] Symbol C C C8 C0 0 0 CM V Note ) Manifold type Base mounted Stations 0 stations 0 0 stations 08 C Port size [() port] Port size ø One-touch fitting ø One-touch fitting ø8 One-touch fitting ø0 One-touch fitting Rc /8 Rc / Mixed port sizes Note ) Specify port mixture/with port plug by means of the manifold specification sheet. Port mixture and port plug are available only for one-touch fitting type. Note ) For inch size One-touch fittings, refer to page 8. C Kit type C Connector Option None D DIN rail mounting (With standard DIN rail length) D0 Note) DIN rail mounting (Without DIN rail) R External pilot type Note ) Order DIN rail separately. For DIN rail part no., refer to page 8. Note ) When two or more symbols are specified, indicate them alphabetically. 00/00 / How to Order Valve M 00 body width mm 00 body width 8 mm Type of actuation N.C. Metal seal N.O. Metal seal N.C. Rubber seal N.O. Rubber seal Caution Use standard (DC) specification for continuous duty. Body type Base mouned Function Symbol Specifications DC C Standard (0. W) Note ) Note ) B High speed response type High pressure type K Note ) (Metal seal type only) Note, ) R External pilot type BR Note, ) High speed response/external pilot type High pressure/external pilot type KR Note, ) (Metal seal type only) Note ) Semi-standard Note ) For details on external pilot type, refer to page 8. Note ) For C specification power consumption, refer to page Non-locking push type (Tool required) B Locking type (Tool required) Symbol G L LO M MO Y YO YZ YS YOS Note ) Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC [ VC] (0/0 Hz) 0 VC [0 VC] (0/0 Hz) VDC VDC Note) C-type models that are have DIN terminals only. Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire M-type plug without DIN terminal DIN terminal without DIN terminal DIN terminal (DC specification) Note ) DIN terminal without (DC specification) IP compliant W Note) Compliant Note) 00/00 DIN terminal rubber seal only (except external pilot). For details on IP enclosure, refer to page 8. Light/surge voltage None Yes None Yes Yes (Without light) C DC Note ) Standard lead wire length: 00 mm Note ) For C voltage valves there is no S type. It is already built-in to the rectifier circuit.

29 Base Mounted 00/00/00 Manifold Specifications 00 Base model V- Piping specifications Piping Port size direction (P), (R) () Side/Top Rc /8 C (for ø.) C (for ø) C (for ø) M (M thread) Note) pplicable pplicable Manifold solenoid stations base valve weight (g) to 0 stations stations: 8 ddition per station: 9 00 V- Side Rc / C (for ø) C (for ø) C8 (for ø8) Rc /8 to 0 stations stations: ddition per station: 8 00 V- Side (P) port C (for ø) Rc /8 C8 (for ø8) (R) port C0 (for ø0) Rc / Rc / to 0 stations stations: 09 ddition per station: 0 Note) Weight for threaded connection. How to Order Manifold ssembly (Example) Stations U side -L sets D side V-0CC V L set (C kit -station manifold base part no.) set (Blanking plate assembly part no.) sets (N.C. type part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Enter in order starting from the first station on the D side. dd the valve and option part number under the manifold base part number. When entry of part numbers becomes complicated, indicate by the manifold specification sheet. C: One-touch fitting for ø V

30 P Grommet (G) D side L U side (). L (Rail mounting hole pitch:.) (Pitch). P = 0.. (DIN rail) pprox. 00 (PE: Pilot EXH port).9 (Station ) (Station n) (For M) 0 () 00/00/00 Dimensions: 00: Top Ported V- Stations Port size C (X: External pilot port) <For external pilot> (DIN rail clamp thread) (.) x ø. (For mounting) [() port]. L P R L L R (8) (.) () One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/".... () /8 [(P), (R) port] C:. N7: 7.9 (.) (7.) The dashed lines indicate the DIN rail mounting [-D]. M pprox () (PE: Pilot EXH port).... PE (). 8 /8 [(P), (R) port] Dimensions L n L L L L L Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations)

31 P (). L L (Rail mounting hole pitch:.) (Pitch). P = 0.. (DIN rail clamp thread) pprox (PE: Pilot EXH port) (.) - + (DIN rail) R (.) ().... () Base Mounted 00/00/00 Dimensions: 00: Side Ported V- Stations Port size C Grommet (G) (X: External pilot port) <For external pilot> D side U side P R.7 (For M) x ø. (For mounting). L L L (Station ) (Station n) (8) (.) C:. N7: /8 [(P), (R) port] [() port] One-touch fitting [() port] pplicable tubing O.D.: ø., ø/8" ø, ø/" ø, ø/" 0.7 (7.) (). (Pitch) P = 0. The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) pprox [7.] 9.9 pprox [.9] 70. [77.] 9. [.] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L Formula: L = 0.n + 9. L = 0.n +. n: Stations (Max. 0 stations)

32 R P D side U side L L () (Rail mounting hole pitch:.) (Pitch) 8 P = (DIN rail clamp thread) (DIN rail) 7.8. PE port (X: External pilot port) <External pilot only> (8) / [(P), (R) port]. /8 /8 [() port]. pprox [.8] pplicable cable O.D. ø. to ø7 Max Pg7 8 [8.] P R 00/00/00 Dimensions: 00 V- Stations Port size C Grommet (G) pprox (.). x ø. (For mounting) L L L (.) () (.9).. () (Station ) (Station n) 0. One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø, ø/" ø8, ø/" () (7.). 0. (Pitch) P = pprox [7.] 7. [7.] 7. (Pitch) P = L-type plug (L) M-type plug (M) DIN terminal (Y) The dashed lines indicate the DIN rail mounting [-D]. 89. Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = n + 0 L = n + 0 n: Stations (Max. 0 stations)

33 R P (.) () Base Mounted 00/00/00 Dimensions: 00 V- Stations Port size C Grommet (G) pprox. 00 D side L L (Rail mounting hole pitch:.) (Pitch) P = 0 U side () (DIN rail clamp thread) (DIN rail). 9. PE port (X: External pilot port) <External pilot only> / [(R) port] () x ø. (For mounting) L 9 L L P R (8) /8 [(P) port] (.). () (Station ) (Station n). One-touch fitting [() port] pplicable tubing O.D.: ø, ø/" ø8, ø/" ø0, ø/8" () (7.) 9. (Pitch) P = 0 / / [() port]. 9. (Pitch) P = 0 The dashed lines indicate the DIN rail mounting [-D]. L-type plug (L) M-type plug (M) DIN terminal (Y) pprox. 00. [7.] pprox [8.8] pplicable cable O.D. ø. to ø7 Max Pg7 89. [9.8] 79.8 [8] Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Dimensions L n L L L L L Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: C Unless otherwise indicated, dimensions are the same as Grommet (G). Formula: L = 0n + 8 L = 0n + n: Stations (Max. 0 stations)

34 00/00/00 Manifold Options Blanking plate assembly V00-0- (for 00) V00-0- (for 00) V00-0- (for 00) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. Blanking plug KP- KP-0 KP-0 KP-08 KP-0 L ød Dimensions pplicable Model fitting size ød. 8 0 KP- KP-0 KP-0 KP-08 KP-0 (mm) L D DIN rail XT00-DR- L 7. s for, enter the number from the DIN rail dimensions table. For L dimension, refer to the dimensions of each kit. () () Each manifold can be mounted on a DIN rail. Insert D at the end of the manifold part number. The DIN rail is approximately 0 mm longer than the length of manifold. L Dimension L =.n + 0. No L dimension No L dimension Silencer (for manifold EXH port) Silencer is installed in the manifold EXH port. ø N0-0 N0-0 ø. Dimensions Model Silencer part no. 00 N N N0-0 Port plug V00-CP (for 00) This is used when changing piping location. (Side or Top) 8

35 Base Mounted Semi-standard Specifications [Option] External Pilot Specification The external pilot specification is used when the operating pressure is below the minimum operating pressure 0. to 0. MPa or when valve is used for a vacuum application. Order a valve by adding the external pilot specification [R] to the part number. Valve Part No. R Entry is the same as standard products. Manifold Part No. V C Entry is the same as standard products. Inch Size One-touch Fittings and Optional Threads Inch size One-touch fittings and NPT, NPTF and G thread are available. Manifold Part No. V N7 T C Entry is the same as standard products. Entry is the same as standard products. Note) The pilot exhaust IP valves is common with main valve exhaust. (The standard valve has an individual exhaust for the pilot valve.) External pilot port Optional Threads Other than Rc Rc specifications are standard for all ports, however, NPT, NPTF and G are available for overseas markets. dd the appropriate symbol following the port size in the standard part number. Valve Part No. T Entry is the same as standard products. IP Enclosure (Based on IEC09) DIN terminal is available with IP enclosure. Cylinder port Symbol N N N7 N9 N NM Note ) M 0 0 pplicable tubing O.D. ø/8" ø/" ø/" ø/" ø/8" Mixed M thread /8 thread / thread Cylinder port Note ) Except 00, mixing One-touch fittings and thread types is impossible. Note ) Metric size One-touch fittings (C) are also available. Valve Part No. (pplicable to the 00/00 rubber seal with the exception of the external pilot type) Y W R Pressure Specifications External pilot pressure range Note ) Metal seal Rubber seal (00: poppet) Operating pressure range Note ) 00 Note ) 00/00 0. to 0.7 MPa 0. to 0.7 MPa 0. to 0.7 MPa 00 kpa to 0.7 MPa Note ) In case of the high pressure type, upper limit of max. operating pressure and external pilot pressure range is MPa. Note ) When using the 00 series for a vacuum application, vacuum air through its (P) port. When supplying vacuum-release air, supply it through its (R) port. But do not supply vacuum-release air exceeding 0% for the external pilot pressure. In addition, when the 00 is to be used at an operating pressure greater than 0. MPa, please assure that the operating pressure is set to equal to or less than the external pilot pressure. Thread type (Cylinder port and (P), (R) ports) Rc N NPT T NPTF F G Thread type (Cylinder port and (P), (R) ports of sub-plate) Rc N NPT T NPTF F G 8

36 Base Mounted Replacement Parts One-touch Fitting ssembly (for Cylinder port) Fitting size Model C C C C8 C0 VV000-0-C VV000-0-C VV000--C Note) Purchasing order is available in units of 0 pieces. VV000-0-C VV000--C VV000--C8 VV000--C VV000--C8 VV000--C0 M (00 only) VV000-0-M Without lead wire: SY00-0- (with and sockets only) <Gasket and screw assembly> Model Lead wire length 00 mm mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm How to Order Include the assembly part number together with the part number for the plug s solenoid valve without. Example) In case of 000 mm of lead wire DC -LO-M SY C -LO-M SY Part no GS GS GS- Note) bove part number consists of 0 units. Each unit has one gasket and two screws. Purchasing order is available in units of 0 pieces. <Sub-plate> <Plug assembly> DC: SY VC: SY VC: SY Other C voltages: SY Sub-plate part no. Model For internal pilot For external pilot S-0 (-) 00-S-0 -R (-) S- 0 (-) 00-S- 0 -R (-) S- 0 (-) 00-S- 0 -R (-) Thread type 8 <Pilot valve assembly> Note) Semi-standard M V Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type (pplicable to 00/00) K Note) High pressure type (pplicable to Metal seal type, Poppet seal type) None (pplicable to 00/00) Yes (pplicable to 00) V G <DIN terminal type (pplicable to the 00/00)> Function Symbol Specifications DC C Standard (0. W) B Note) High speed response type K Note) High pressure type (Metal seal type only) Note) Semi-standard Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Symbol Y YO YZ YS Note) YOS Note) Symbol DC C G LU LOU MU LZ LOZ MZ Valve model -L -M Y Coil voltage 00 VC (0/0 Hz) 00 VC (0/0 Hz) 0 VC (0/0 Hz) 0 VC (0/0 Hz) VDC VDC Grommet (DC specification) L-type plug with lead wire L-type plug without M-type plug with lead wire (pplicable to the 00) MOU MOZ M-type plug without Note) The electrical entry (L, M) for the 00 pilot valve is different from that of the main valve model number. Pilot valve model VM-M VM-L X0 Non-locking push type Locking slotted type Light/surge voltage None Yes Light/surge voltage Caution When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V (DIN terminal) from a V (Grommet, L-type, M-type), or vice versa. B DIN terminal DIN terminal without DIN terminal with light/surge voltage DIN terminal with surge voltage (DC specification) DIN terminal with surge voltage, without (DC specification) None Yes Yes (Without light) Note) For C voltage valves there is no S option. It is already built-in to the rectifier circuit.

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Series M Applicable Tubing: ø2 Connection Thread: M3, M5

Series M Applicable Tubing: ø2 Connection Thread: M3, M5 iniature Fittings Series pplicable Tubing: ø2 onnection Thread:, RoHS ade to Order (Refer to page for details.) pplicable O.D. x I.D.: ø2 x ø.2 onnection thread: / One-touch fitting size: ø.2 / ø Tubing

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175}

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175} Solenoid Valve Features 2 For DC power supply 3 For C power supply These models realize high-pressure large-flow-rate control at 35 MPa {35 kgf/cm 2 } and 1 L/min (2) or 16 L/min (3). They are best suited

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits. Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

zamak nitrile rubber self-extinguishing technopolymes aluminum

zamak nitrile rubber self-extinguishing technopolymes aluminum G 0 mm - G / Valves and solenoid valves - G/ threaded valve body with traditional Univer spool system - Version with integrated connection and esternal connection - Compact design - High flow rate - Versions

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25

Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load

More information

size 3 15 4200 size 4 19 6600

size 3 15 4200 size 4 19 6600 BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

Table of Contents. MicroAir Series...3-9

Table of Contents. MicroAir Series...3-9 Table of Contents MicroAir Series...-9 Technical and Operating Data.... How to Order.... Valve on ndividual Base... 5 Manifold Assemblies... 6 End Plate Kits... 7 Blank Station Plate Kit.... 7 Blocking

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890 CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5

More information

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System Module: Series ZX Ejector System/External Supply System ZX ZR ZM Suitable for handling electronic components and precision components up to 100g Modular Design Customized application function through selection

More information

servo-controlled 3-WaY vacuum solenoid valves WiTH

servo-controlled 3-WaY vacuum solenoid valves WiTH servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 50 bar (5000 psi) and 7 L/min (60 USgpm) n Eaton rand ETON Screw-In Cartridge Valves E-VLSC-MC00-E November 009 -.

More information

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information