ROLLING STOCK CABLES
|
|
- Berniece Sherman
- 8 years ago
- Views:
Transcription
1 CABLES UNIPOLAIRES EXTRA-SOUPLE SANS GAINE UNSHEATHED SINGLE CORE CABLES WITH EXTRA-FLEXIBLE CONDUCTOR CARACTERISTIQUES DU CABLE CABLE CHARACTERISTICS - 40 C Bon Résistant à Bon / Good Tenue au feu Zero halogène Sans plomb Good huile EN Fire behaviour Zero halogen Without lead Oil EN EN resistant EN EN Bon / Good EN EN EN voir page 2 / see on page DESCRIPTIF DU CABLE AME / CONDUCTOR âme extra souple en cuivre recuit étamé ou cuivre rouge, ronde, câblée, classe 6 CABLE DESIGN extra flexible circular tin-coated annealed copper or plain copper conductor, class 6 conforme à / according to EN température / temperature 120 C en régime permanent / in continuous duty C en court circuit / in short circuit ou /or 150 C en régime permanent / in continuous duty C en court circuit / in short circuit N.B. Pour utilisation à 150 C en régime permanent, l'âme doit être impérativement en cuivre nu recuit - Nous consulter For use at 150 C in steady operation, it is imperative that the conductor is annealed plain copper - Consult us ISOLATION / mélange silicone / silicone compound conforme à / according to EN (EI 112) couleur / colou r : NOIRE / BLACK Marquage / Marking (exemple / example) PRYSMIAN 255 -TEROL HT TX - EN V 185 F 120 C X N de lot / batch No. Catalogue - Indice E du 02/12/2009 1/7
2 NORMES D'ENVIRONNEMENT ET D'ESSAIS ENVIRONMENTAL AND TEST STANDARDS Environnement Environment TS HL4 TS HL4 (équivalent à NF F C F0, BS la (equivalent to NF F C F0, BS la & DIN 5510) & DIN 5510) Tenue au feu Fire performance essai à la flamme EN flame test EN (NF C C2, CEI (NF C C2, IEC & DIN VDE ) & DIN VDE ) essai au feu EN fire test EN (CEI & DIN VDE ) (IEC & DIN VDE ) + EN EN (ex BS & 3, et DIN VDE A-C) (ex BS & 3, et DIN VDE A-C) Absence d'halogène Halogen free performance EN (CEI ) EN (IEC ) EN EN Corrosivité / Toxicité Corrosivity / Toxicity toxicité EN toxicity EN acidité et toxicité des gaz EN acid and toxic gases EN (CEI ) & NF X (IEC ) & NF X Dégagement de fumées Smoke emission faible dégagement de fumée EN low smoke EN (CEI & DIN VDE ) (IEC & DIN VDE ) C C ex BS & 2, et DIN VDE ex BS & 2, and DIN VDE CERTIFICATS D'HOMOLOGATION HOMOLOGATION CERTIFICATES ALSTOM SNCF RATP Catalogue - Indice E du 02/12/2009 2/7
3 Définition des tensions (V) Voltage definition (V) Tension Tension assignée / Assigned voltage nominale EN Nominal Courant alternatif (c.a.) Courant continu (c.c.) voltage Alternatice current (a.c.) Direct current (d.c.) (V) Uo U Um Vo V CONDITIONS DE POSE LAYING CONDITIONS D < 12 mm r = 3 D D > 12 mm r = 4 D avec D = diamètre extérieur du câble with D = cable outer diameter Catalogue - Indice E du 02/12/2009 3/7
4 CARACTERISTIQUES DIMENSIONNELLES DIMENSIONAL CHARACTERISTICS Code produit Section Ø sur épaisseur Ø extérieur Code product nominale âme nominale nominale Masse d'isolation EN (1) Noir Vert/jaune Nominal Ø over Insulation Outer Mass cross conductor nominale nominal Ø Black Green/yellow section thickness (approx) (1) (approx) mm² mm mm mm kg/km PHUFX301 PHUFX ,6 3,0 15,7 ± 0,5 570 PHUFX302 PHUFX ,0 3,0 17,5 ± 0,6 770 PHUFX303 PHUFX ,5 3,0 19,0 ± 0,6 980 PHUFX304 PHUFX ,2 3,1 20,8 ± 0, PHUFX305 PHUFX ,8 3,1 22,3 ± 0, PHUFX306 PHUFX ,5 3,2 24,2 ± 0, (1) Toutes les épaisseurs sont conformes aux normes EN (1) All thicknesses are according to EN standards Catalogue - Indice E du 02/12/2009 4/7
5 CARACTERISTIQUES ELECTRIQUES ELECTRICAL CHARACTERISTICS Section Résistance Résistance Réactance Capacité Intensité Chute de Résistance Résistance nominale maxi à 20 C maxi à 120 C à 50 Hz admissible tension d'isolement d'isolement en c.c. en c.a. cos j = 0,8 mini à 20 C mini à 120 C (1) (1) (2) (3) Minimum Minimum Nominal Maxi d.c. Maxi a.c. EN Capacitance Permissible Voltage insulation insulation cross resistance resistance at 50 Hz current drop resistance resistance section at 20 C at 120 C (approx) (approx) rating cos j = 0,8 at 20 C at 120 C mm² W/km W/km W/km µf/km A V/A/km MW.km MW.km 50 0,393 0,548 0,10 0, , ,4 70 0,277 0,386 0,09 0, , ,0 95 0,210 0,293 0,09 0, , , ,164 0,229 0,08 0, , , ,132 0,185 0,08 0, , , ,108 0,152 0,08 0, , ,1 Conditions de validité / Validity terms (1) Résistance en cuivre nu (cuivre étamé sur demande) / plain copper resistance (tinned copper on request) (2) Intensités pour 1 conducteur / Permissible current ratings for 1 core Pour câbles multiconducteurs avec 2, 3 ou 4 conducteurs chargés, il convient de multilier ces valeurs par 0,8. For multicore cables with 2, 3 or 4 loaded conductors, these values must be multiplied by 0,8. conforme à / according to EN 50343: Annexe B Ces valeurs sont applicables pour une seule liaison posée à l'air libre, à l'abri du soleil, température ambiante 45 C, température maximum à l'âme en régime de fontionnement 120 C, pour température de 150 C voir norme. These values are applicable for a single line in free air, sheltered from the sun, ambient temperature 45 C, maximum conductor temperature 120 C in continuous working, for 150 C temperature see standard. (3) Les valeurs de chute de tension approximatives mentionnées dans les tableaux sont celles d'une liaison TRIPHASE Approximate voltage drop values noticed in the table are according to a THREE PHASE CURRENT Catalogue - Indice E du 02/12/2009 5/7
6 CARACTERISTIQUES ELECTRIQUES ELECTRICAL CHARACTERISTICS Section nominale COURANT DE COURT-CIRCUIT DANS LES AMES A Nominal EN cross SHORT CIRCUIT CURRENT RATING IN CONDUCTORS section A mm² 0,1 s 0,2 s 0,5 s 1 s 2 s 5 s Conditions de validité / Validity terms température initiale / initial temperature = 120 C température finale / final temperature = 250 C selon / according to IEC Catalogue - Indice E du 02/12/2009 6/7
7 FACTEURS DE CORRECTION CORRECTION FACTORS FACTEURS DE CORRECTION Température EN POUR S AMBIANTES DIFFERENTES DE 45 C Temperature CORRECTION FACTORS FOR AMBIENT OTHERS THAN 45 C C A 35 1, , , , , , , , ,26 selon / according to EN 50343: Annexe D Catalogue - Indice E du 02/12/2009 7/7
Catalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationL304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR
MECHANICAL CHARACTERISTICS CARACTERISTIQUES MECANIQUE PRINCIPAL TECHNICAL CHARACTERISTICS CARACTERISTIQUES TECHNIQUES PRINCIPALES 3 possible versions - Single indicator - Momentary action pushbutton (1
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationCapteur température et humidité pour HVAC
Capteur température et humidité pour HVAC oct-13 Type R 590 Type R 591 Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement
More informationS1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head
S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head Fonction Sonde de température à visser avec tête de raccordement suivant codification (voir au verso). Function Threaded
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationPower Distribution System. Additional Information on page 2 See Page 2 Page 6. Eaton. See Page 2. Additional Information on page 2
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationSectionneur rotatif traversant d intérieur Wall bushing disconnector for indoor substation
REF. CL/0248/b Sectionneur rotatif traversant d intérieur Wall bushing disconnector for indoor substation TYPE SR2002 72,5 kv - intensité / nominal current 2000 A - BIL 325 kv Icc / Ith 31,5 ka / 3 sec
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
More informationISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationEDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationCB Test Certificates
IECEE OD-2037-Ed.1.5 OPERATIONAL & RULING DOCUMENTS CB Test Certificates OD-2037-Ed.1.5 IECEE 2011 - Copyright 2011-09-30 all rights reserved Except for IECEE members and mandated persons, no part of this
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationCompact I/O End Caps/Terminators
Installation Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationSwitching Power Supply XP POWER INC. SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER INC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationCERTIFICATE OF COMPLIANCE
CERTIFICATE OF COMPLIANCE Certificate Number 20131115-E240353 Report Reference E240353-A17-UL Issue Date 2013-NOVEMBER-15 Issued to: HGST, A WESTERN DIGITAL COMPANY 5601 GREAT OAKS PKY SAN JOSE CA 95119
More informationMITSUBISHI ELECTRIC JET TOWEL HAND DRYER CANNON AIR JET
File No. NJNE3737D MITSUBISHI ELECTRIC JET TOWEL HAND DRYER MODEL: JT-SB216ESH-W-CE JT-SB216ESH-DG-CE JT-SB216GSN-W-CE JT-SB216GSN-DG-CE CANNON AIR JET MODEL: JT-SB216ESH-W-CH JT-SB216ESH-DG-CH TECHNICAL
More informationCOMMISSION INTERNATIONALE DE KARTING - FIA
FICHE D HOMOLOGATION HOMOLOGATION FORM Homologation N 3/P/ COMMISSION INTERNATIONALE DE KARTING - FIA PNEUMATIQUE / TYRE Manufacturier Tyre Manufacturer Reifenwerk Heidenau GmbH Marque Make MOJO Modèle
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationAVENANT D'ArrESTATION D'EXAMEN CE DE TYPE Lei 2 Appareil ou systeme de protection destine aetre utilise 2 en atmospheres explosibles (Directive 94/9/CE) 3 Numero de I'avenant : 3 LCIE 99 ATEX 6006 X 104
More informationLOW VOLTAGE POWER CABLES
LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED
More informationDirect AC Wiring Option Installation Guide
Revision A Direct AC Wiring Option Installation Guide The direct AC wiring option enables you to wire AC power directly in to the ADP InTouch. The option kit contains the following parts. 25mm 12mm Caution:
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationNote concernant votre accord de souscription au service «Trusted Certificate Service» (TCS)
Note concernant votre accord de souscription au service «Trusted Certificate Service» (TCS) Veuillez vérifier les éléments suivants avant de nous soumettre votre accord : 1. Vous avez bien lu et paraphé
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationFire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
More informationIECEE OPERATIONAL DOCUMENT
IECEE OD-2037 Edition 1.7 2014-04-11 IECEE OPERATIONAL DOCUMENT IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System) CB Test Certificates IECEE OD-2037:2014(E)
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationLeI E. Henri CERVELLO
AVENANT D'ArrESTATION D'EXAMEN CE DE TYPE LeI E SUPPLEMENTARY EC TYPE EXAMINATION CERTIFICATE 2 Appareil ou systeme de protection destine aetre utilise 2 Equipment or protective system intended for use
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationB05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
More informationThe Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
More informationDECLARATION DE CONFORMITE Declaration of Conformity
DECLARATION DE CONFORMITE Declaration of Conformity Nous, We, ABB Control (nom du Fournisseur / Supplier's name) 10 rue ampère, ZI 69685 CHASSIEU (France) (adresse / address) déclarons sous notre seule
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationAMPLIFICADORES PARA MÁSTIL Y ALIMENTADORES AMPLIFIERS FOR MAST AND POWER SUPPLIES AMPLIFICATEURS POUR MÂT ET ALIMENTATIONS SERIE 903 SERIES AMPLIFICADOR PARA MÁSTIL - AMPLIFIER FOR MAST - AMPLIFICATEUR
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationArchived Content. Contenu archivé
ARCHIVED - Archiving Content ARCHIVÉE - Contenu archivé Archived Content Contenu archivé Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationNEW GENERATION AGA-LED LIGHTING UNITS
festoon lamp new generation AGA-LED A-10 rigid loop connector new generation AGA-LED A-10 festoon connector SCALE 1:1 new generation AGA-LED B-10 rigid loop connector ALL PRODUCTS ARE USA, EUROPE AND JAPAN
More informationModel 685B0011C14. Vibration Switch. Installation and Operating Manual
Model 685B0011C14 Vibration Switch Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationVDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
More informationSwitching Power Supply DELTA ELECTRONICS, INC. CTF Stage 2. Additional Information on page 2. E356265-A27-CB-1 issued on 2015-09-23
DK-48708-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE)
More informationArchived Content. Contenu archivé
ARCHIVED - Archiving Content ARCHIVÉE - Contenu archivé Archived Content Contenu archivé Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject
More informationComparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
More informationINSIGHT LONG EFFECT. gerflor.com VOYEZ PLUS GRAND LOOK FURTHER
INSIGHT LONG EFFECT gerflor.com VOYEZ PLUS GRAND LOOK FURTHER INSIGHT LONG EFFECT DONNEZ DE LA PROFONDEUR À VOTRE INTÉRIEUR LONGER PLANKS FOR THE FEEL OF MORE SPACE Plus de 1.20 M de réalisme! / Bevelled
More informationCONNECTEURS CONNECTORS. axocoax
CONNECTEURS CONNECTORS N axocoax N Sommaire Summary Spécifications Specifications Fiches mâles Male plugs p. 2 to 3 A SERTIR CRIMP Droites Straight p. 4 Coudées Right angle p. 5 A SOUDER CLAMP Droites
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationAD511 Active Iridium Antenna User Manual Mar 12 V4.0
AD511 Active Iridium Antenna User Manual Mar 12 V4.0 AD511 Active Iridium Transmitter/Receiver Antenna with up to 160 metres of coaxial down-lead and DC Power Break-In Box for Iridium Satellite Systems
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More informationRAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN
RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN RAIL /// WIRE & CABLE EVERY CONNECTION COUNTS The Rail industry is changing rapidly, to match global demands for greener, more intelligent transportation.
More informationSun Enterprise Optional Power Sequencer Installation Guide
Sun Enterprise Optional Power Sequencer Installation Guide For the Sun Enterprise 6500/5500 System Cabinet and the Sun Enterprise 68-inch Expansion Cabinet Sun Microsystems, Inc. 901 San Antonio Road Palo
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 62313 Edition 1.0 2009-04 Railway applications Power supply and rolling stock Technical criteria for the coordination between power supply (substation) and
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationALUMINIUM. Conductors
ALUMINIUM Conductors TABLE OF CONTENTS The ALUMINIUM AND ALUMINIUM ALLOYS WIRES technical data Aluminium wires...p 3 in this catalog Hard aluminium are given for _hard aluminium information Other states
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More information