Spool Center Condition * Orifice Closed Open 2-Position Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize

Size: px
Start display at page:

Download "Spool Center Condition * Orifice Closed Open 2-Position Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize"

Transcription

1 echnical Information General directional control valves are high performance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Features Soft shift available. 21 standard spool styles available. roportional spools. DC surge suppression. Nine electrical connection options. C & DC lights available (CS approval for solenoids and lights). Internally ground. Easy access mounting bolts. Waterproof (meets NEM 4, up to I67 on some models). Eplosion proof. CS approvals. Specifications Mounting attern NF D03, CEO 3; NG 6 Mounting DIN Interface ISO CEO R35H , NF D03 Maimum,, ressure 345 ar (5000 SI) Standard CS 276 ar (4000 SI) ank: 103 ar (1500 SI) C only 207 ar (3000 SI) DC/C Rectified Standard C Optional CS 103 ar (1500 SI) U.L. recognized available - Contact Division. No tools required for coil removal. C rectified coils. Leakage Rates* Maimum llowable: cc (1.2 Cu. in.) per 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per 207 ar (3000 SI)* *#008 and #009 ypical: Spools may 4.9 cc (0.3 Cu. in.) per eceed these rates. 69 ar (1000 SI)* Consult Factory 26.2 cc (1.6 Cu. in.) per 345 ar (5000 SI) Response ime Response time (milliseconds) at 345 ar (5000 SI) is 32 LM (8.5 GM). Solenoid ype ull-in Drop-Out C DC 8 Watt or 10 Watt DC 30 Watt p65, dd 15 Spool Center Condition * Orifice Closed Open 2-osition Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize S S S S C 175 ms 700 ms 600 ms 800 ms 150 ms 200 ms DC 200 ms 650 ms 700ms 650 ms 175 ms 225 ms C 150 ms 400 ms 500 ms 600 ms 100 ms 150 ms DC 125 ms 325 ms 550 ms 550 ms 100 ms 100 ms C 125 ms 300 ms 450 ms 500 ms 100 ms 100 ms DC 100 ms 250 ms 500 ms 450 ms 75 ms 60 ms C 100 ms 250 ms 400 ms 450 ms 50 ms 100 ms DC 50 ms 225 ms 400 ms 400 ms 50 ms 40 ms * Step response times were obtained under the following conditions: 100 SSU 120 F with the valve operating at nominal pressure and flow. ublished response times are nominal and may vary with spool, flow, pressure and temperature. arker Hannifin Corporation Elyria, Ohio, US

2 Ordering Information Series D1V Standard Valves D Directional Control Valve 1V asic Valve ctuator Spool Style Seal Solenoid Voltage p65, dd NF D03 CEO 3 DIN NG6 Symbol Symbol * * 008*, 030** 009** W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. old: Designates ier I products and options. N Nitrile V Fluorocarbon E* ER Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D Double solenoid, 2 position, detent. E Single solenoid, 2 position, spring centered. to and to when energized. F Single solenoid, 2 position. Spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K * Contact HVD for availability. Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * 020, 026 and 030 spools only. 020 and 030 spools only. High Watt only. Non-old: Designates ier II products and options. hese products will have longer lead times. ** D G J K L N*** *** Q** QD R U Y Z b 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC 220/50 VC 110/50 VC 100/60 VC 100/60-100/50 VC 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC ** High Watt only *** Eplosion roof only. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a springcentered valve eists when both coils are deenergized, or during a complete shift, as the spool passes through center. b b b b a a a a a 16 arker Hannifin Corporation Elyria, Ohio, US

3 Ordering Information Series D1V Standard Valves C Solenoid Connection Conduit o D Metric lug (M12X1), DESIN E* Eplosion roof G J * lug-in Conduit o Deutsch (D06-2S) M * Metri-ack (150) S * DIN with lug Double Spade W* DIN w/o lug * Not available with lights. DC only. Coil Options ube Options Options Electrical Options Omit Shift Response and Indication Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice I7** I8** Monitor Switch Direct Op. End Stroke Monitor Switch Direct Op. Start Stroke * Not available with 8 watt, must have DC tube. **, E, H & K styles only. Spools 8,9,21,26,81,82 not available. Not CE or CS approved. pprovals Valve Design Variations Series NOE: Not required when ordering. Omit D E F** High Watt Eplosion roof, EEXD EX Eplosion roof, EEXME EX Low Watt C CS Hazardous Location L*** O U Valve Weight: Single Solenoid Double Solenoid Standard olt Kit: Metric olt Kit: 8 Watt Eplosion roof, MSH Eplosion roof, UL/CS X* No Coils * See solenoid voltage code to specify proper tube. ** C only. *** DC and C Rectified only. pplicable to conduit bo and plug-in style only kg (3.0 lbs.) 1.6 kg (3.5 lbs.) K209 KM209 Omit Omit Standard * Etended with oot * No W* Waterproof rotection * override options not available on eplosion proof or soft shift. Low ressure, C only ar (1500 SI) H* High ressure, C only 207 ar (3000 SI) G Omit J** Standard ressure, DC/C Rectified 207 ar (3000 SI) * Not available with CS. No Options Diode Surge Suppressor Rectified Coil DC tube standard. ** Not applicable with DIN plug with lights. Omit Standard Valve 3* CS US (UL429) 4* CS Canada * Not available with C high pressure tube., C, H styles only. J, K, Y, U voltages only. C, G, W sol. connections only. 5 Signal Lights 6 Manaplug - rad Harrison Mini 7 Manaplug - rad Harrison (121) Micro 56 Manaplug (Mini) with Lights C 1D 1M Manaplug (Micro) with Lights Manaplug (Mini) Single Sol. 5-pin Manaplug (Micro) Single Sol. 5-pin Manaplug (Mini) Single Sol. 5-pin, with Lights Manplug (Micro) Single Sol. 5-pin, with Lights Manaplug Opposite of Normal 4D wist & Lock (Old 5426) 4E ush (Old 5450) 4F 1 Heavy Duty Detent ainted ody DC/C Rectified only. Not available with soft shift p65, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 17 arker Hannifin Corporation Elyria, Ohio, US

4 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -10% to +15% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Eplosion roof Solenoid Ratings* UL & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the NEC MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Ed, Group II; EN50014: mds. 1 & 2, EN50018: 2000 CS Hazardous Location Class II, Div 1 & 2, Groups E, F & G * llowable Voltage Deviation ±10%. Note that Eplosion roof C coils are single frequency only. Voltage ower Voltage In Rush mps mperage In Rush mps D1VW 3MM Holding mps D1VW Watts D1VW Resistance D1VW 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohms D L 120 VDC N/ N/ 0.09 mps 10 W ohms N/ N/ 0.26 mps 30 W ohms G L 198 VDC N/ N/ 0.05 mps 10 W ohms N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms N/ N/ 5.00 mps 30 W 1.20 ohms Q 100 VC / 60 Hz 1.7 pms 170 V 0.56 mps 24 W 26.0 ohms QD 100 VC / 60 Hz 0.41 mps 135 V 0.41 mps 18 W 31.2 ohms QD 100 VC / 50 Hz 0.57 mps 150 V 0.57 mps 24 W 31.2 ohms R 24/60 VC, High Watt 8.00 mps 192 V 2.70 mps 27 W 1.40 ohms F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms 240/60 VC, High Watt 0.77 mps 185 V 0.26 mps 25 W ohms 220/50 VC, High Watt 0.82 mps 180 V 0.31 mps 27 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms Y 120/60 VC, High Watt 1.55 mps 186 V 0.49 mps 25 W ohms 110/50 VC, High Watt 1.65 mps 182 V 0.58 mps 27 W ohms F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms N/ N/ 0.13 mps 30 W ohms Eplosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms Q 100/60 VC 1.90 mps 192 V 0.70 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms D 120 VDC N/ N/ 0.28 mps 33 W ohms Z 250 VDC N/ N/ 0.13 mps 33 W ohms p65, dd 18 arker Hannifin Corporation Elyria, Ohio, US

5 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in o, Double DC Solenoid 44.9 (1.77) 87.8 (3.46) (5.66) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a springcentered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center Min. Coil (2.14) Removal 1/2 NF hd. oth Ends 49.6 (1.95) 24.8 (0.98) 66.0 (2.60) 93.2 (3.67) (9.62) lug-in o, Single DC Solenoid 44.9 (1.77) 87.8 (3.46) 1/2 NF hd. oth Ends 49.6 (1.95) 24.8 (0.98) 54.3 (2.14) Min. Coil Removal (7.42) 66.0 (2.60) 93.2 (3.67) p65, dd 19 arker Hannifin Corporation Elyria, Ohio, US

6 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double DC Solenoid 12.0 (0.47) Min. Connector Removal 72.6 (2.86) (4.54) (5.59) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center (2.14) Min. Coil Removal 25.3 (1.00) 23.0 (0.91) 66.3 (2.61) 77.6 (3.06) (9.62) Hirschmann, Single DC Solenoid 23.0 (0.91) 25.3 (1.00) 54.3 (2.14) Min. Coil Removal (3.97) 72.6 (2.86) 12.0 (0.47) Min. Conn. Removal 77.6 (3.06) 66.3 (2.61) (6.63) p65, dd 20 arker Hannifin Corporation Elyria, Ohio, US

7 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Double C Solenoid 36.8 (1.45) (5.00) 79.9 (3.15) (1.68) Min. Coil Removal Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. ½ NF hread oth Ends 49.5 (1.95) 24.8 (0.98) 3.0 (0.19) See Note 66.0 (2.60) 94.6 (3.72) (8.30) Conduit o, Single C Solenoid (1.68) Min. Coil Removal 84.0 (3.31) 36.8 (1.45) ½ NF hread oth Ends 49.5 (1.95) 24.8 (0.98) 3.0 (0.19) 66.0 (2.60) 94.6 (3.72) (6.44) p65, dd 21 arker Hannifin Corporation Elyria, Ohio, US

8 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Double C Solenoid with Variation 6 (Manaplug) & Variation (Etended ) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center (1.45) (4.99) 95.7 (3.77) 42.8 (1.69) Min. Coil Removal Connector NF (1.00) He 49.5 (1.95) 3.0 (0.19) 24.8 (0.98) Etended 66.0 (2.60) 94.6 (3.72) Solenoid Reverse Sides for # 8 & 9 Spool 61.2 (2.41) Minimum Coil Removal (8.86) Solenoid Reverse Sides for # 8 & 9 Spool Conduit o, Double DC & C Rectified Solenoids with Variation 6 (Manaplug) & Variation (Etended ) Etended 36.8 (1.45) 79.9 (3.15) 95.7 (3.77) (5.59) 54.3 (2.14) Min. Coil Removal Connector per NF (1.00) He 66.0 (2.60) 3.0 (0.19) 49.5 (1.95) 24.8 (0.98) 94.6 (3.72) p65, dd 72.7 (2.86) Min. Coil Removal (10.01) 22 arker Hannifin Corporation Elyria, Ohio, US

9 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Deutsch Double DC Solenoid Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center (3.65) (5.59) Min. Coil Removal 20.0 (0.79) 5.66 (0.22) 2.83 (0.11) 23.0 (0.91) 54.2 (2.13) 65.5 (2.58) (9.62) Deutsch Single DC Solenoid 92.7 (3.65) (5.59) Min. Coil Removal 20.0 (0.79) 5.66 (0.22) 2.83 (0.11) 23.0 (0.91) 54.2 (2.13) 65.5 (2.58) (6.63) p65, dd 23 arker Hannifin Corporation Elyria, Ohio, US

10 Dimensions Inch equivalents for millimeter dimensions are shown in (**) DESIN, Double DC Solenoid Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. Light 48.0 (1.89) 90.7 (3.57) (5.59) 54.3 (2.14) Min. Coil Removal 70.3 (2.77) 50.8 (2.00) (9.54) DESIN, Single DC Solenoid Light 90.7 (3.57) (5.59) 543 (2.14) Min. Coil Removal 70.3 (2.77) 50.8 (2.00) (6.59) p65, dd 24 arker Hannifin Corporation Elyria, Ohio, US

11 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Eplosion roof U.L. & C.S.., Double Solenoid 60.4 (2.38) (6.44) 18 Inch Lead Wires Standard 1/2" N 94.4 (3.72) (5.15) (11.98) Eplosion roof M.S.H.., Double Solenoid 73.0 (2.87) (0.30) 3/4-20 UNF hd (2.38) (6.44) 3/4-20 UNF hd (1.50) (4.45) (5.15) (6.44) Eplosion roof EX, Double Solenoid 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) M H hd. Ground Stud with Lockwasher 73.0 (2.87) (0.30) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center (3.97) 42.8 (1.69) (5.19) (3.96) p65, dd 7.5 (0.30) 73.5 (2.89) (5.55) (12.78) arker Hannifin Corporation Elyria, Ohio, US

12 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Single DC Solenoid with Variation I7 (Monitor Switch) & Variation (Etended ) 72.7 (2.86) Min.Coil Removal (4.53) 12.0 (0.47) Min. Conn. Removal 3.0 (0.12) 49.5 (1.95) 24.8 (0.98) Etended (10.82) 81.9 (3.22) 70.6 (2.78) 94.6 (3.72) Monitor Switch (valve variation I7 and I8) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. lock Diagram Inductor Regulator (Etended, or Energized osition) in 2 (Input 24VDC) in 1 (Output Normally Open) in 3 (Output Normally Closed) in 4 (Ground erminal) For repetitive switch power-up conditions, please consult factory p65, dd 26 arker Hannifin Corporation Elyria, Ohio, US

13 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid Solenoid (ositive) Wire #1 (Red/White) Solenoid (Negative) Wire #5 (Red/lack) Solenoid (Negative) Wire #2 (Red) Solenoid (ositive) Wire #4 (Red/Yellow) Ground Wire #3 (Green) 5-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid Double Solenoid Valves Installed Over Solenoid ( and Solenoids Reversed for #8 and #9 Spools) ins are as seen on valve (male pin connectors). Conduit o (Standard/lug-In; Option G) Meets Nema 4/I67 Signal Lights (Option 5) LED Interface Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form p65, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) 27 DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected 5 3 arker Hannifin Corporation Elyria, Ohio, US

14 ccessories Series D1V Mounting olt Kits olt Kits for use with D1V & Manapaks (D1V*-82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated) Number of Manapaks at 44.5mm (1.75") hickness Note: Number of (1.58") thickness K in. K in. K in. K in. K in. KM mm KM mm KM mm KM mm KM mm K in. K in. K in. K in. KM mm KM mm KM mm KM mm K in. K in. K in. KM mm KM mm KM mm K in. K in. KM mm KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Eplosion roof Coils & Manapaks (D1V*-82 & 70/75 Design) Number of Manapaks at 44.5mm (1.75") hickness Note: Number of (1.58") thickness K in. K in. K in. K in. K in. KM50 50 mm KM mm KM mm KM mm K in. K in. K in. K in. KM51 95 mm KM mm KM mm K in. K in. K in. KM mm KM mm K in. K in. KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Manapak valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58") thickness. For additional technical information about Manapak valves, refer to the Manapak Sandwich Valve Section of this Catalog. 7.0 (0.28) 14.5 (0.57) 45.0 (1.77) p65, dd 36 arker Hannifin Corporation Elyria, Ohio, US

15 Closed Crossover Open Crossover Symmetrical Standard Catalog HY /US Universal Spool Chart Series D1V D 020H H D 030H H Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool Symbol D1V* D1V* D3*W D31DW D41 D41*W D61VW D81/D91 D101VW D111 D1V*: Double Double Spool 0 D1VW: /C// D31*DW/ Monitor HCD Monitor HVD HCD HVD HCD Number D1VHW D/G/L D31DW Switch Switch HVD = HCD = Hydraulic Controls Division Gray = available White = not available Spools shown may be nonstandard. lease contact HVD for availability p65, dd 38 arker Hannifin Corporation Elyria, Ohio, US

16 Closed Crossover Open Crossover Symmetrical Standard Catalog HY /US Universal Spool Chart Series D1V Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool Symbol D1V* D1V* D3*W D31DW D41 D41*W D61VW D81/D91 D101VW D111 D1V*: Double Double Spool 0 D1VW: /C// D31*DW/ Monitor HCD Monitor HVD HCD HVD HCD Number D1VHW D/G/L D31DW Switch Switch H H H H H H H Gray = available White = not available HVD = HCD = Hydraulic Controls Division Spools shown may be nonstandard. lease contact HVD for availability p65, dd 39 arker Hannifin Corporation Elyria, Ohio, US

17 Installation Information Series D1V Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) at 38 C (100 F) is recommended. he absolute operation viscosity range is from cst. ( SSU). Oil should have maimum anti-wear properties and rust and oidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, FLUOROCRON seals are required. Waterglycol, (95/5) water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -29 C to +71 C (-20 F to +160 F) Filtration For maimum valve and system component life, the system should be protected at a contamination level not to eceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unepected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are epected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Flow ath Data D1V Operator Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition eists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approimately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs) p65, dd 40 arker Hannifin Corporation Elyria, Ohio, US

Directional Control Valves

Directional Control Valves echnical Information General he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position

More information

KDG3V-5/7/8, 10 Series

KDG3V-5/7/8, 10 Series Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Introduction Manapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D03, D05 and D08 sandwich style valve. The NFPA D03 valve body conforms

More information

RA 23 178/08.99. Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

RA 23 178/08.99. Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids 4/3-, 4/- and 3/ Directional Control Valves Model WE 6.. /E, Series 6X with wet pin C or DC solenoids Size 6 (D 03) up to 5100 SI (350 ar) up to 1 GM (80 L/min) R 3 178/06.98 R 3 178/08.99 Replaces: 06.98

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Directional Controls

Directional Controls Vickers Directional Controls DG5S-8 and DG5S-H8 wo-stage, Solenoid Controlled, ilot Operated, Four-Way Directional Valves Revised 11/94 591 Introduction General Description he DG5S-8 and DG5S-H8 are two-stage

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits. Vickers Pressure Relief Pressure Relief and Sequence Valves CG2V-6/8, 1 Series; CG5V-6/8, 2 Series Typical Section CG2V-6*W-1 relief valve Basic Characteristics Maximum pressure.......... 35 bar (5 psi)

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

Pressure Relief Valves for Pipe Mounting

Pressure Relief Valves for Pipe Mounting Vickers ressure Relief ressure Relief Valves for ipe Mounting EC-6/1, 1 Series; EC5-6/1, 3 Series ypical Section EC5-1 example asic Characteristics Max. pressure...... 25 bar (3625 psi) Max. flow rates:

More information

Oil Pressure Regulating Valve

Oil Pressure Regulating Valve Oil ressure Regulating Valve In adopting and using this product. Safety recautions ype Number Index 2 3 4 Directional control valve - ressure control valve 2- Flow control valve 3- Sandwich valve 4- Logic

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175}

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175} Solenoid Valve Features 2 For DC power supply 3 For C power supply These models realize high-pressure large-flow-rate control at 35 MPa {35 kgf/cm 2 } and 1 L/min (2) or 16 L/min (3). They are best suited

More information

DIRECTIONAL CONTROL VALVES

DIRECTIONAL CONTROL VALVES Series 35 High Flow High Pressure Directional Valves D05SD DIN Type D05S Electrical Box Type D03SD DIN Type D03S Electrical Box Type D03SL Lead Wire Type (D05SL Lead Wire Type Also available) FEATURES

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment Vickers Directional Controls Solenoid Operated Directional Valve DGV-3S, EN 90 For Mobile Equipment Flows to 0 l/min (10.5 USgpm), * Design P, A & B Pressures to 350 bar (5000 psi), T Pressures to 10 bar

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

005 SERIES MODULAR VALVES. Pub. EC-1401. General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type

005 SERIES MODULAR VALVES. Pub. EC-1401. General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type 5 SERIES General Information Up to 5 Ma (3 SI), 1 L /m in (6 USGM) ub EC-11 MODULR VLVES hese modular valves have the same mounting surface as those for the DSG-5 solenoid operated directional valves and

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW D660 Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Pressure Relief. Pressure Relief Valves. Vickers

Pressure Relief. Pressure Relief Valves. Vickers Vickers Pressure Relief Pressure Relief Valves Remote Controls, Relief and Sequence Valves, and Single and Multiple Pressure Solenoid and Air Operated Relief Valves 511./EN/1297/A Introduction Remote Controls

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 50 bar (5000 psi) and 7 L/min (60 USgpm) n Eaton rand ETON Screw-In Cartridge Valves E-VLSC-MC00-E November 009 -.

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General

More information

Ref.nr.: www.hydroflex.nl. Oud-Beijerland Willem Beukelszstraat 1 3261 LV Oud-Beijerland Nederland Telefoon: +31(0)186 620 777

Ref.nr.: www.hydroflex.nl. Oud-Beijerland Willem Beukelszstraat 1 3261 LV Oud-Beijerland Nederland Telefoon: +31(0)186 620 777 Ref.nr.: Oud-eijerland Willem eukelszstraat 1 3261 LV Oud-eijerland elefoon: +31(0)186 620 777 russel 1853 Strombeek - ever elgië elefoon: +32(0)2 267 41 14 elefoon: +31(0)10 283 90 00 Ordering s ypical

More information

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)

DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) 83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Load-sensing control block in mono and sandwich plate design

Load-sensing control block in mono and sandwich plate design Load-sensing control block in mono and sandwich plate design RE 64276/08.2010 Replaces: 08.2008 1/64 Type M4-12 Nominal size 12 Unit series 2X Nominal pressure 350 bar (pump side) Nominal pressure 420

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

2-way flow control valve Type 2FRM 6

2-way flow control valve Type 2FRM 6 RE /0.0 Replaces:.0 -way flow control valve Type FRM Nominal size Series X Maximum operating pressure bar ) Maximum flow L/min ) When used in conjunction with a rectifier plate up to 0 bar H//D /97 + H//D

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

SystemStak. SystemStak Valves. Vickers

SystemStak. SystemStak Valves. Vickers Vickers SystemStak SystemStak Valves ISO 4401-05 size, 315 bar (40 psi) and 120 l/min (32 USgpm) maximum ratings ressure relief and reducing, sequence, counterbalance, and flow control functions Revised

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SERIES RF00 RF00D RF00DD RF0 RF0D RF0DD RELAY TYPE Repeatable, RF relay Repeatable, RF relay with internal diode for coil transient suppression Repeatable,

More information

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS Hydraulic components POCLAIN HYDRAULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Seat Valves. 1 Description. Series SVH04. 1.1 Technical data. 1.2 Performance graphs

Seat Valves. 1 Description. Series SVH04. 1.1 Technical data. 1.2 Performance graphs Seat Valves Series SVH0 ctuators are shut-off with virtually zero-leakage, even over a longer period of time Particularly suitable for mobile machines, thanks to the low-weight design and small dimensions

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...

More information

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) Type 4WRPEH 6 Size (NG) 6 Unit series 2X Maximum working pressure

More information

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...

More information

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C 41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY28-2662-CD/US Series PAVC Variable Displacement Piston Pumps zp1 Catalog HY28-2662-CD/US 1 Introduction Series PAVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *Approx. Noise

More information

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure reducing valve, direct operated, Type ZDR 6 D RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Catalog HY15-3502/US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Catalog HY15-3502/US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes... Contents Coils and SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Tubes... 3-4 CA... 5/8 Tubes... 5-6 STANDARD COILS Unicoil... 1/2 Tubes... 7-8 Unicoil... 5/8 Tubes... 9-10 DS... 1/2 Tubes... 11-12

More information

Open center control block in monoblock design MO-40

Open center control block in monoblock design MO-40 Open center control block in monoblock design MO-40 RE 64370 Edition: 02.2015 Replaces: 02.1985 Size 40 Series 1X Maximum working pressure on pump side 350 bar on consumer side 420 bar Maximum flow 680

More information