Type examination certificate No. CH-MI e Bauartprüfzertifikat
|
|
- Ferdinand Cox
- 8 years ago
- Views:
Transcription
1 Confederation suisse Confederazlone SYlzzera Confederazlun syizra Federal Departement of Juslice and Police Fedenll Office of Metrology Certification Body METAS-Cert Type examination certificate No. CH-MI e Bauartprüfzertifikat Applicant: Auftraggeber: Requirements: Anforderungen: Type of instrument: Geräteart: Type designation: Typenbezeichnung: SIKA Aquatec GmbH Struthweg Kaufungen Oirective 2004/221EC of the European Parliament and Council of March 31, 2004 on measuring instruments (MIO), Appendix B, Measuring Instrument Category MI-001 Richtlinie EG des Europaischen Parlaments und des Rates vom 31. MaTZ 2004 Ober Messgerate (MID), Anhang B, Messger3tekategorie MI-OOI Swiss ordinance on measuring instruments (SR ) of February 15, 2006 annex 2 module B Schweizerische Messmittelverordnung (SR ) vom 15. Februar 2006, Anhang 2 Modul B Axial turbine water meter for hot and cold water (T90) WKV E02F Accuracy class(es): 2 Genauigkeitsklasse: Characteristics: Kenndaten: PN 10, ON 10, T90, Klasse/Class B, E1, Q, 1.0, R10 Certificate valid until: 16 February 2019 Zertifikat gallig bis: CH-3003 Bern-Wabern, July 14, 2009 Notified body: Certificate authority METAS-Cert Benannte Stelle: No For the test: Far die PrOfu"g: ~ Or Hugo Bissig Jürg Ramseyer, Head of METAS-Cert Thls documeni may not be published or fofwarde<! other than in Juli Die~s Dolwmf!nt darf nur in voilsj:jndiger Form weitergegeben werden. 1/6 MET" lindtnweg SO, CH 3003 Bern-Wilbern, Tel...' 3' }l n 111,
2 Schweizerische EIdgenossenschi1ft Conf~deriltlon Sl,Ilsse Confederilzlone Svizzeril Confederil~il,ln SVlzrii Beilage zu BauartpriJfzertifikat 1. Harmonised standards or standardisation documents applied EN 14154: 2007 Edition; OIML R 49: 2006 Edition. 2. Name and construction type of the measuring device Axial turbine water meter for hot and cold water Type denomination: W'tW E02F 3. Description of the Type The WKV E02F is an axial turbine water meter for hot and cold water (T90) with a nominal range of DN10, which can be adapted to a variety of attachment sizes and additional adapters to the assembly array. The WKV collects consumption data and stores thern ready to be read off subsequently. These consumption data are displayed on the liquid crystal display (LCD) and can be read off retrospectively using a standard optocoupler. The data can also be read off rernotely via radio transmission from outside the residential complex using the WKV E02F model. 4. Construction The WKV E02F comprises two parts: one mechanical and the other electronic. The mechanical flow meter assembly is built into the measuring tube and is evaluated by means of a pulse sensor and computer electronics. The pulse sensor and the computer electronies are available in a compact version or a split version. In the compact version, the pulse sensor is built into the computer electronics and is attached to the measuring tube with a fixture clip. Drawing N 400/ : illustrates the dimensions of the compact version WKVE02F Drawing N 400/ : axial turbine flow meter, mechanics and electronics WKVE02F Parts list number : Parts list dated accompanying Drawing N" 400/ In the split version, the pulse sensor is attached to the measuring tube with a fixture clip and connected to the computer electronics by cable. Drawing N 400/ : illustrates the dimensions of the split version WKV E02F Drawing N 400/ : axial turbine flow meter, mechanics and electronics split version WKV E02F Parts list number : Parts list dated accompanying Drawing N" 400/ Measuring device The water meter's mechanical measuring unit comprises an axial turbine flow sensor, wh ich is built into the measuring tube. The turbine is sealed at the entrance and the exit with an 8-hole disc made of plastic. The turbine and the dividing disc are made with such dimensions that no clogging should be expected when working under normal conditions and smaller particles will be flushed through. DIese. Dokument darf nur In YOIlständiger Form weitefgtlgeben werden 11ul document m,y not MI pubhslifid (X forw,rded other rhall", fu~ 218."" und",,-&:!io. (H'jOO3 8e... wabe.n. T~. ' 3' 32 n "'. wwwmetahh
3 Confl!dl!ration suisse Confederazlone Svizzera Confederazlun svlzra Beilage zu BauartprUfzertifikat Parts list number : Parts list dated accompanying Drawings N" 400/ and 400/ and their referenees to the re spective individual part Drawing Numbers. Drawing N VT-0956: overview ofaxial turbine flow sensor type VTY 10 MS-30, dated and its references to the respective individual measuring tube variant Drawings. 6. Computing device The pulse sensor and the computer electronics are available in a compact version or a split version. The pulse sensor (Wiegand) generales impulses on the basis of the rotation of the magnets installed in the turbine and feeds them on to the computer electronics, so that the volume in m 3 is accumulated constantly from the number of impulses, as the value of the impulses is set at 512 impulses/litre. Parts list number : Parts list dated accompanying Drawings N" 400 / and 400 / and theirreferenees to the re spective individual part Drawing Numbers. Doeument N" : 0590P001 dated Doeument N" : 0590P002 dated Liquid Crystal Display in normal operations When there is no f10w through the tube, the LCD will stay in standby mode. When there is a flow, the display will be activated and the cumulative volume will appear, expressed in m 3, with aresolution of 6 digits, three of which are after the decimal point. This means that the maximum cumulative volume that can be displayed is m 3. As a result of the reading protocol via the optical interface, there is no risk that the display will run over without being noticed. Opto-e/ectronic interface The entire data memory in the M-Bus standard protocol can be read off in compliance with EN using a standard optocoupler via the opto-electronic interface. In a rolling memory, the monthly values are stored in 15 registers, so that any display overrun can be checked al any time. Remote readings The water meter is fitted with a retrospective, two-way radio system, with which all the information in the data memory in the M-Bus standard protocol can be read off in compliance with EN The radio address co rresponds 10 the serial number printed on the water meter, which can also be read off electro-optically. DIeses Dokument darl nur in \IQII, tllndiger Fonn weitergegeben werden. Thi$ document may noi "- publlshed or frxwarded olmr th." In MI. "'''' L,"den~ SO> CH )oo) 8ern.Wabem. Tel. +41 )' )1)) www m~a$.ch
4 Con fl!deralion suis~e Con federazione Svizzera ConfederilZlun SVlzra Beilage zu BauartprlJfzertifikat 7. Technical data Q, I (m /h) 1.0 Q. I (m /h) 1.25 Q,/Q R (Q"Q,) Overall length: Straight measuring tube Measuring tube with eccentric (mm) Connection size: In f1ow thread Out f1ow thread Installation location Pressure loss class bp H /V 63 Calibration value I 0.1 Water pressure class MAP MPa 1.6 Temperature dass T90: Accuracy class (Ql S Q s Q 2). (Q, <Q < Q.l Environmental and mechani cal classification ElectromaQnetic classification Flow dislurbance classifica tion Power supply DN10 G3/8. G1/2: AG. IG G3/8. G3/4. G1 /2: AG IG O.1 C<T<90 "C 2,atT<30 "C ±5% ±2% Class B I Class M1 5 C-55 "C Class E1 UO/DO Lithium battery 2, at T< 30 "C ±5% ±2% 8. Requirements tor production. commissioning and using Requirements tor production The final metrological test must be conducted in compliance with OIML R 49-1, 2006 edi tion, with the following three through flows at a water temperature of 50 oe ± 10 oe for hot water (T90): 1.00,s O s 1.10, 1.0 O,s 0 s 1.10, 0.9 O, s 0 s 1.0 0, Any discrepancy of the display may not exceed the maximum permissible tolerance in the case of any of the above specified through flows. Requirements tor commissioning The WKV E02F can be used on au common water connection points in the household and in industry, as lang as it is installed directly before the tap, so as to avoid any water return. If this is not possible, a non-return valve must be insta Ued before the water meter, so as to stop the water flowing back in any way. Advice tor users If you try to remove the computer electronics, you will destroy the attachment clip: this will Oieaes Ookumenl darf nur in OfQIIsUlndiger Form weitergegeben werden Tlms docu/mrit m.y not oe publ<sh&d (X kxw,rded OIl!er,h.n In MI Mn" l.ndtnw.g~, CH 1OO3 8ern WJ,b!rn, Te-! ~4' 3' m. _.melu.eh
5 Confederation sulsse Confederazlone SVlzzera Confederazlun svlzra Annex to the type examination certificate no. CH.MI _e Belfage zu BauartprOfzertifikat trigger the identification of the aperture, leading to an electronic recording being made of the event. Attempts to use external magnets to influence the magnetic impulses will also be recorded electronically by the magnet monitoring system. 9. Advice for running checks on devices while they are operating Documents (or the check The Type Examination Certification and the technical description of the testing procedure can be found in the User Instructions. The opto-electric interface can be used to read off the information from the data memory at the beginning and the end of the ~ Start from a standstill - Stop" procedure and the volumes that have flowed through can be calculated to an accuracy of at least m 3. Test equipment The test can be eonducted on a volumetrie, gravimetrie or eomparative counter basis. The lesl equipmenl used musl cover Ihe flow rales specified in paragraph B. Metrological test The metrological test must be conducted within the nominal operating eonditions. 10. Locations of marks and compliance symbol The computer electronies attachment dip in the compact version and the two attachment cl ips in the split version double to fulfil the mechanical sealing function, as they are destroyed when the device is opened. Every form of mechanical manipulation can be traced and proved, as it will all be recorded electronically. The GE symbol, the metrological M, the conformity assessment body number issued by the GAB responsible and the Type Examination Gertificate Number must be applied in a suitable location. Symbols applied 10 Ihe WKV E02F (example): L,.r.,,.J c:.,.,... b'j:.jc I ~ i).~.. -, fi,ii I~"J 888ßP~ _..J._!, Dieses Dokument darf!\ur In voit.l.lndiger Fonn weiter!il4'geben werden Tht$ documeni may not be pubji~fie(l ~ rorwlht1ed other /han in fu/l... "'''' Undenwe, So. CH )OO) Be,n.Wil~'n. Tel.,,1)1)2 ))111, _.metn.ch
6 Conf~d~ratlon suisse Confederazione Svizzera Confede riilziun $vina Beilage zu BauartpriJfzertifikat 11. Terms of placing on the market The meter must bear the following information: a, R Class Type Examination Certificate N Manufacturer's trademark er name Year of productien and serial number Direction of flow Maximum operating pressure, if other than PN 1.0 MPa Maximal temperature, if ether than class T History of certificate Edition Date Descriptien CH-MI _ e July Translation of the first type examination certificate CH 3003 Bern-Wabern. July 14, 2009 Dieses Dokument darf nur in VQllstandiger Form weitergegeben werden, TIIi$ documtlnt may not be publi$hed or forwarded other than in ru/i MIT'" linden_g So. CH'3003 Sern Wabern, Tel, +4' 3' 32 33,no
Type examination certificate No. CH-MIOO1-11052-00 BauartprufzertifIkat
Federal Department ofjustice and Police FDJP Federal Office of Metrology METAS Ceiflcation Body METAS-Cert Type examination certificate No CH-MIOO1-11052-00 BauartprufzertifIkat Applicant: GGIOANOLA SRL
More information20099 Sesto San Giovanni (Ml) Italy. (MID) RichtIinie 2004/22/EG des Europaischen Parlaments und des
Applicant: I.G.S. DATAFLOW S. r. I. Bauartprufzertifikat No. CHM10021 I 00800 Type examination certificate This document may not be published or forwarded other than in full. METAS Lindenweg 50, CH3003
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
More informationCORONA E / FLYPPER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationWELMEC European cooperation in legal metrology
WELMEC 11.2 Issue 1 WELMEC European cooperation in legal metrology Guideline on time depending consumption measurements for billing purposes (interval metering) May 2010 1 WELMEC European cooperation in
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationAMTRON E-30 Compact heat and cooling meter
AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,
More informationMULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter
Ultrasonic measurement Pinpoint accuracy Longevity Vacuum sealed construction Environment-friendly meter MID-2004/22/EC M12 0200 Electronic ultrasonic cold and hot water meter MULTICAL 21 is used for measurement
More informationHow To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
More informationCertificate of EC type-examination of a measuring instrument Number: UK/0126/0102
(UK/0126/0102) MI-001 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0102 issued by the Secretary of State for Business,
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationWIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
More informationCertificate of Calibration No 131 00835
Schweizerische Confederation Confederazione Confederaziun Eidgeno5senschaft suisse svizra Federal Department of Justice alld Police FDJp Federal Office of Metrology METAS Certificate of Calibration No
More informationFluxi 2000/TZ Turbine Gas Meter
Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.
More informationExperience with taximeters with a look at the corresponding tables
Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 mprasil@cmi.cz Taximeters in EU are subject to
More informationWELMEC European Cooperation in Legal Metrology
WELMEC 11.1 Issue 5 January 2014 WELMEC European Cooperation in Legal Metrology Measuring Instruments Directive 2004/22/EC Common application for utility meters WELMEC European Cooperation in Legal Metrology
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationSafety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
More informationIFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
More informationMOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationThreaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
More information3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
More informationUser Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationThe multi-functional integrator Supercal 531
The multi-functional integrator Supercal 531 Design The Supercal 531 integrator is suitable for connecting Pt 500 or Pt 100 temperature sensor pairs with 2 or 4-conducting wire techniques. Volume inputs
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationSmart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.
Smart Wireless Devices LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device. The LAN-WMBUS-G-T(E)/(H)-(P) is a temperature/humidity sensor and pulse counter. It is
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More informationZ-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION
Product Manual NQ-9121-EU Z-Wave Gas Reader From your Z-wave network directly to the cloud! DESCRIPTION The NorthQ Gas Reader is a small device based on the Z-Wave wireless standard-ideal for home automation.
More informationTHE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,
More information5235 Single Phase Credit Meter
Electricity Meters Residential BS / IEC British Standard 5235 Single Phase Credit Meter User Manual & Technical Specification Date: 20/11/08 Filename: 5235 User Manual Q Pulse No:IB047 Landis+Gyr Page
More informationT U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationElectromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
More informationBrunata Optuna W (171)
Brunata Optuna W (171) Communication description Edition 1.1 UK-QB101414 / 26.02.2013 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing meters,
More informationSITRANS F flowmeters SITRANS FUS080. Flowmeter FUE380 with approval. 4/202 Siemens FI 01 2008. Overview
SITRANS F flowmeters Siemens AG 2008 Overview The 2-track flowmeter SITRANS FUE380 comes as battery or mains powered and is designed to measure water flow in district heating plants, local networks, boiler
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More informationSITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL 3000 4/179. flow sensor pipe, 4 transducers/transducer cables and a transmitter
Overview SITRANS FUS380 flow sensor pipe, transducers/transducer cables and a transmitter SITRANS FUS080. The unit is available in a compact or a remote version with up to 30 meter distance from flowmeter
More informationBattery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
More informationElectro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
More information1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications
1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30 Water Metering
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationSITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010
Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationTHERMAL ENERGY METER MC 108/ET
USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta
More informationBNI IOL-709-000-K006 BNI IOL-710-000-K006. IO-Link Sensor-Hub analog User s Guide
BNI IOL-709-000-K006 BNI IOL-710-000-K006 IO-Link Sensor-Hub analog User s Guide Inhalt 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationCONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
More informationSeries 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
More informationEC Type-Approval Certificate UK 2943
UK 2943 V(0)a EC Type-Approval Certificate UK 2943 issued by the: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-Automatic Weighing Instruments Regulations
More informationBattery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
More informationGSM COMMUNICATORS CATALOGUE
COMMUNICATORS CATALOGUE ( ) 870020/B - 07/2007 - Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble 311 586 382 The services and product data presented in this document may be modified without prior notice
More informationInstructions for assembly and use MULTICAL 601
Instructions for assembly and use MULTICAL 601 www.kamstrup.com 1.1 MID labelling Standard conditions of operation/measuring rates: Meter θ: 10 C 180 C Θ: 3K 170K A pair of resistance temperature sensors
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationEuropean Technical Approval ETA-10/0200
Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts Kolonnenstr. 30 B 10829 Berlin Germany Tel.: +49(0)30 787 30 0 Fax: +49(0)30 787 30 320 E-mail: dibt@dibt.de Internet: www.dibt.de Mitglied
More informationSentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
More informationORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar
Chiavari (Ge) - Italia Tel.: Italia + 0185 + 38.50.10 Fax: Italia + 0185 + 38.50.11 e-mail: orlando@orlando.it Http://www.orlando.it M R 50...: Radial pressure gauge ø 50 ( available scale in bar: 4, 6,10,12,16
More informationConductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationSONOMETER TM 1000 Ultrasonic compact heat meter
Data sheet SONOMETER TM 000 Ultrasonic compact heat meter Description/Application MID examination certificate no. : DE-07-MI004-PTB02 The SONOMETER 000 is an ultrasonic static compact heat meter especially
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationThe New Counting Champions
1949 2009 YEARS OF INNOVATION Single-phase and Three-phase Energy Meters and Energy Consumption Indicator The New Counting Champions Three-phase energy meter DSZ12D for direct connection with display and
More informationCERTIFICATE of Product Conformity (QAL1 )
ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000043528 Certified AMS: Manufacturer: Test lnstitute: F-701-20 for particulate matter PMio DURAG GmbH Kollaustraße
More informationHighly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
More informationHOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H
HOSCH Sprung blade scraper with heating system Documentation Type B6C/H 1 HOSCH Sprung blade scraper Type B6-C/H with heating system Table of contents 1 Intended use Page 3 1.1 Use 1.2 General operating
More informationSHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide
SHARKY 775 Ultrasonic Compact Energy Meter Installation and User Guide for software version F01-001 1 Contents 1 General... 4 1.1 About this Installation and User Guide... 4 1.1.1 Target groups...4 1.1.2
More informationBypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationCONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
More informationred-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
More informationMeasurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
More informationUS Installation Manual Smappee Monitor
US Installation Manual Smappee Monitor Version 1.3 English, US, version 1.3, revision 23, as of October 23, 2014, 2013 Smappee NV. All rights reserved. Specifications are subject to change without notice.
More information67273 EN V40/14 NOUVAG AG, all rights reserved Subject to change. Laparoscopic Hysterectomy Morcellator
67273 EN V40/14 NOUVAG AG, all rights reserved Subject to change Laparoscopic Hysterectomy Morcellator Laparoscopic Hysterectomy Nowadays newly developed medical devices make hysterectomy possible by a
More informationDigital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7
Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters
More informationWater Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System
Water Metering System SmartMeter Prepayment SmartMeter Prepayment Water Metering System Water Metering System SmartMeter Prepayment SmartMeter Prepayment Water Metering System A dynamic approach to Prepayment
More informationFlexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
More informationC13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationTEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING
DELIVERY PROGRAMME TEMPERATURE MEASURING - Resistance temperature sensors into a reservoir, - with a reservoir, with protection tube, with cable - Resistance temperature sensors Ex to zones 2, 1 - - and
More informationEuropean Technical Approval ETA-06/0259
European Technical Approval ETA-06/0259 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationFT-1000/GPS-N. System of remote monitoring and control of physical
FT-1000/GPS-N System of remote monitoring and control of physical Localization of vehicles during transport by sending the values of temperature, RH%, etc.. with relative alarm threshold is exceeded. Send
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationMINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationTF KEYBOARDS. inputs whose state can be displayed via software. They can be used immediately with the TE electromechanical keyboard [see accessories].
TF KEYBOARDS FIELDBUS keyboards Main applications Keyboards to manage machine movement in the following sectors: - Plastics - Packaging - Wood - Metalworking Main characteristics 32 keys - 32 LEDs USB
More informationevohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
More informationSeries description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
More informationPROFORMA ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT
RP&AD /Remote QA/ 01 PROFORMA FOR ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT BHABHA ATOMIC RESEARCH CENTRE Radiological Physics & Advisory Division CT & CRS Building,
More informationDIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
29.3.2014 Official Journal of the European Union L 96/149 DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationCounter for Energy. We make energy measurable and secure your future. www.g-mw.de
Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
More informationROTALIGN Ultra is The intelligent System for Machinery Alignment
ROTALIGN Ultra is The intelligent System for Machinery Alignment 2 sensalign improves the quality of your alignment XXL HD PSD (Ultra-large High Definition Position Sensitive Detector) At a glance Real
More informationMPR-Systems. Mini Power Racks 1200 W - 8100 W
LUCAS-BENNING World Class Power Solutions With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen Germany
More information