Certificate of Calibration No

Size: px
Start display at page:

Download "Certificate of Calibration No 131 00835"

Transcription

1 Schweizerische Confederation Confederazione Confederaziun Eidgeno5senschaft suisse svizra Federal Department of Justice alld Police FDJp Federal Office of Metrology METAS Certificate of Calibration No Object Order Applicant Traceability Date of Calibration Swiss Committee Kilogram 1 kg Kilogramme Conforme a la Loi du 18 Germinal an 3, presente Ie 4 Mess an 7. Fortin F Brass, in a leather box Historical comparison of mass and conventional mass in the context of the exhibition: Ferdinand Rudolf Hassler ( ) - Swiss Pioneerfor US Surveying, Mapping and Standards, to be presented at METAS, July 8 - August 11, Federal Office of Metrology METAS Lindenweg 50 CH-3003 Bern-Wabern The reported measurement values are traceable to national standards and thus to internationally supported realizations of the SI-units Marking CH-3003 Bern-Wabern, 08 May 2007 For the Measurements Section Mechanics 7 /;f-2t k:crav' Stefan Russi Dr Henri Baumann, Head of Section ~ Mutual recognition 1.- This certificate is consistent with Calibration and Measurement Capabilities (CMCs) that are included in Appendix C CIPMMRA of the Mutual Recognition Arrangement (MRA) drawn up by the International Committee for Weights and Measures. Under the MRA. all participating institutes recognize the validity of each other's calibration certificates and measurement reports for the quantities, ranges and measurement uncertainties specified in Appendix C (for delails see This document may ~ot be published or forwarded other than in futl >I' "IT'" Lindenweg,0, CH-J003 Bern-Wabern, Tel. +4' J1 3' 33 lll.

2 Schweizeri,che Eidger1o$sertschaf l COl1f~d~ratiol1 sui,se Confede.razior1e Confederaziun 5vizra Extent of the Calibration The mass and conventional mass of the Committee Kilogram has been determined, in accordance to the International Recommendation OIML R 111-1, 'Weights of classes E" E 2, F l, F 2, M l, M l _2, M 2, M 2 _3 and M 3 ", edition 2004 (OIML: International Organization of Legal Metrology). Measurement procedure The mass and conventional mass of the Committee Kilogram was determined on the mass comparator M_One, by comparison with METAS reference standards sets number 4, number 14 and number 336 by substitution weighing. Picture 1: Committee Kilogram inside the primary Mass Comparator of Metas This document may nm be published or forwarded other then in full, 215 M"''' Undenweg 50, CH-lDO} Bern-Wobem, T.L +4'l' 3. 33"'

3 Schweizerische Eidgenossenschaft Confederation suisse ConfecJerazione Svizzer(l Confederaziun svizra Picture 2: Committee Kilogram within its original protection case Picture 3: Imprint at the bottom of the weight ThiS document may not be published or forwarded other than in full "IT" Linoenweg So, CH-JooJ Bern-Wabern, Tel. +4' 3' J~13 " I, ch

4 Schweizerische Confederation Conlederazione Conlederaziun Eidgenossenschaft suisse svizra Picture 4: Engraved label on the top of the leather coated container TillS document may no! be pubhslled or kl1wardedotl\er than in full '" "IT" Undenweg So, CH'3003 Bern.Waber1l. Tel. "-4' 3' "'.

5 Schweizerische Eidg 1105S 115chaft Confederatiol1 suisse Confederazione Svizzeril Confederaziun svizril Measurement conditions The average ambient conditions during the measurement Air temperature: (20.39± 0.02) C. Air density: (1.111± 0.003)kg/m' were the following: Measurement results After having applied the air buoyancy correction to each series of substitution weighings, the following values for the mass deviation and for the conventional mass deviation has been evaluated: Nominal Identification Mass value deviation Conventional Uncertainty of Density mass deviation measurement (kg/m') 1 kg Uncertainty of Measurement The reported uncertainty of measurement is stated as the combined standard uncertainty multiplied by a coverage factor k = 2. The measured value (y) and the associated expanded uncer~ tainty (U) represent the intelval (y ± U) which contains the value of the measured quantity with a probability of approximately 95%. The uncertainty was estimated following the guidelines of the ISO. The measurement uncertainty contains contributions originating from the measurement standard, from the calibration method, from the environmental conditions and from the object being calibrated. The long-term characteristic of the object being calibrated is not included. ThIS document may not be published or forwarded other than in full M'"'' Undel1weg SO.CH.}oo] ~.Wa~rn. T~1.+4']' }2 ]] ch

Calibration Certificate

Calibration Certificate P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING

More information

Calibration Service Selection Guide

Calibration Service Selection Guide Calibration Service Selection Guide Certification of Accreditation available for download at www.ricelake.com/accreditation. Answer Questions to determine the calibration service you need Need accredited*

More information

Type examination certificate No. CH-MIOO1-11052-00 BauartprufzertifIkat

Type examination certificate No. CH-MIOO1-11052-00 BauartprufzertifIkat Federal Department ofjustice and Police FDJP Federal Office of Metrology METAS Ceiflcation Body METAS-Cert Type examination certificate No CH-MIOO1-11052-00 BauartprufzertifIkat Applicant: GGIOANOLA SRL

More information

The Calibration Chain: Role of BIPM,

The Calibration Chain: Role of BIPM, The Calibration Chain: Role of BIPM, PSDLs and ADCLs J. Seuntjens and M. McEwen McGill University & National Research Council CANADA Clinical Dosimetry for Radiotherapy, 2009 AAPM Summer School PSDL ADCL

More information

Estimates of Uncertainty of the Calibration of Balances

Estimates of Uncertainty of the Calibration of Balances Estimates of Uncertainty of the Calibration of Balances Chart shows the uncertainty (estimates) of the calibration of representative electronic balances. Chart. Uncertainty of calibration (estimates) Minimum

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475

More information

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results Safe and Simple Weight Calibration with ComparatorPac TM ComparatorPac Weight Calibration for Traceable Results

More information

CCM.M-K3.1 comparison / 50 kg Mass

CCM.M-K3.1 comparison / 50 kg Mass CCM.M-K3.1 comparison / 50 kg Mass The 7 th of April 2010 G. MANN - T. MADEC - P.A. MEURY Laboratoire Commun de Métrologie LNE-CNAM Abstract This comparison is a subsequent to the CCM.M-K3 comparison performed

More information

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials COOMET Recommendation Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials CООМЕТ R/RM/22:2013 Agreed at the 17 th meeting of COOMET

More information

Calibration method for conductivity cells

Calibration method for conductivity cells INTERNATIONAL OIML R 68 RECOMMENDATION Edition 1985 (E) Calibration method for conductivity cells Méthode d étalonnage des cellules de conductivité OIML R 68 Edition 1985 (E) ORGANISATION INTERNATIONALE

More information

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS REFERENCES NIST Special Publication 330 IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS Revised October 2013 International vocabulary of metrology Basic and general concepts and

More information

OIML R 111-1 RECOMMENDATION. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION , E 2. Weights of classes E 1 , F 2 , M 1 2 , M 1

OIML R 111-1 RECOMMENDATION. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION , E 2. Weights of classes E 1 , F 2 , M 1 2 , M 1 INTERNATIONAL RECOMMENDATION OIML R 111-1 Edition 2004 (E) Weights of classes E 1, E 2, F 1, F 2, M 1, M 1 2, M 2, M 2 3 and M 3 Part 1: Metrological and technical requirements Poids des classes E 1, E

More information

S Davidson, M Perkin, M Buckley

S Davidson, M Perkin, M Buckley No. 71 Measurement Good Practice Guide The Measurement of Mass and Weight S Davidson, M Perkin, M Buckley The National Physical Laboratory is operated on behalf of the DTI by NPL Management Limited, a

More information

WEIGHTS AND MASS STANDARDS

WEIGHTS AND MASS STANDARDS WEIGHTS AND MASS STANDARDS IN ACCORDANCE WITH THE OIML R111: 2004 MADE BY WEEGTECHNIEK HOLLAND B.V. Patroonsweg 23-27 3892 DA Zeewolde The netherlands Tel. +31 (0)36-5222030 Fax. +31 (0)36-5222060 E-mail:

More information

Gravimetric determination of pipette errors

Gravimetric determination of pipette errors Gravimetric determination of pipette errors In chemical measurements (for instance in titrimetric analysis) it is very important to precisely measure amount of liquid, the measurement is performed with

More information

Measuring equipment in a laboratory.

Measuring equipment in a laboratory. Measuring equipment in a laboratory. Laboratory and metrology are two words that practically do not function separately. They are integrally connected to measuring equipment for tests and measurements.

More information

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS-020000, identification se table of results.

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS-020000, identification se table of results. utfärdat av riksmätplats 01 issued by a Swedish National Laboratory Contact person Lars-Erik Josefson 2014-03-27 1 (3) MTv4F006969-K01 Measurement Technology +46 10 516 54 56 larserik.josefson@sp.se EcoGuard

More information

How To Test A Titrette And Digital Burette

How To Test A Titrette And Digital Burette Titrette and Digital Burette (all models) Testing Instructions (SOP) May 2013 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of bottle-top burette. The following Testing

More information

This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-96SR18500 with the U. S. Department of Energy.

This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-96SR18500 with the U. S. Department of Energy. This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-96SR18500 with the U. S. Department of Energy. DISCLAIMER This report was prepared as an account of work sponsored

More information

NMI R 125 Measuring Systems for the Mass of Liquids in Tanks

NMI R 125 Measuring Systems for the Mass of Liquids in Tanks NMI R 125 Measuring Systems for the Mass of Liquids in Tanks (OIML R 125:1998(E), IDT) The English version of international standard OIML R 125:1998 Measuring Systems for the Mass of Liquids in Tanks (1998)

More information

RECOMMENDATION. on the Evaluation of Quality Management System of National Metrology Institutes

RECOMMENDATION. on the Evaluation of Quality Management System of National Metrology Institutes EURO-ASIAN COOPERATION OF NATIONAL METROLOGICAL INSTITUTIONS COOMET ЕВРО-АЗИАТСКОЕ СОТРУДНИЧЕСТВО ГОСУДАРСТВЕННЫХ МЕТРОЛОГИЧЕСКИХ УЧРЕЖДЕНИЙ КООМЕТ Approved on the COOMET Quality Forum 25 th February 2002

More information

4-1 Ratios, Rates, and Unit Rates

4-1 Ratios, Rates, and Unit Rates Warm Up Problem of the Day Lesson Presentation Lesson Quizzes Warm Up Divide. Round answers to the nearest tenth. 1. 420 23.3 2. 73 3.5 18 21 3. 380 23.8 4. 430 23.9 16 18 Learn to work with rates and

More information

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL DOCUMENT OIML D 18 Edition 2008 (E) The use of certified reference materials in fields covered by metrological control exercised by national services of legal metrology. Basic principles

More information

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1 Process Measurement Assurance Program For U.S. State Metrology Laboratories 1 Jerry L. Everhart JTI Systems, Inc. And Georgia L. Harris NIST Office of Weights and Measures Abstract This paper describes

More information

LAB14 EDITION 4 November 2006

LAB14 EDITION 4 November 2006 LAB14 EDITION 4 November 2006 Calibration of Weighing Machines CONTENTS SECTION PAGE 1 Introduction 2 2 Calibration of Weights 2 3 Considerations in the use of weighing machines 4 4 In-house calibration

More information

ERRATUM: OIML R 60 RECOMMENDATION. Edition 2000 (E) ORGANISATION INTERNATIONALE ORGANIZATION INTERNATIONAL. Metrological regulation for load cells

ERRATUM: OIML R 60 RECOMMENDATION. Edition 2000 (E) ORGANISATION INTERNATIONALE ORGANIZATION INTERNATIONAL. Metrological regulation for load cells ERRATUM: INTERNATIONAL RECOMMENDATION OIML R 60 Edition 2000 (E) Metrological regulation for load cells THIS ERRATUM ONLY CONCERNS THE ENGLISH VERSION OF R 60 (2000) ORGANISATION INTERNATIONALE DE MÉTROLOGIE

More information

Welcome to Physics 40!

Welcome to Physics 40! Welcome to Physics 40! Physics for Scientists and Engineers Lab 1: Introduction to Measurement SI Quantities & Units In mechanics, three basic quantities are used Length, Mass, Time Will also use derived

More information

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance INL/CON-10-18643 PREPRINT Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance 2010 NCSL International Workshop and Symposium Michael Stears July 2010 This is

More information

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards March 2003 GMP 11 Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards 1. Introduction 1.1. Purpose Measurement processes are dynamic systems and often

More information

IS YOUR INFORMATION SECURE? Secure and reliable ICT. Our experience. Your benefit. SWISS CYBER SECURITY

IS YOUR INFORMATION SECURE? Secure and reliable ICT. Our experience. Your benefit. SWISS CYBER SECURITY IS YOUR INFORMATION SECURE? Secure and reliable ICT. Our experience. Your benefit. SWISS CYBER SECURITY Security Services Identify and reduce risks The reliable protection of your assets information, workforce,

More information

High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers

High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers Schweizerische Gesellschaft für Strahlenbiologie und Medizinische Physik Société Suisse de Radiobiologie et de Physique Médicale Società Svizzera di Radiobiologia e di Fisica Medica Swiss Society of Radiobiology

More information

Training Material for Balances (1) Prepared by R&D Division 1. Marketing Department A&D Company, Limited

Training Material for Balances (1) Prepared by R&D Division 1. Marketing Department A&D Company, Limited Training Material for Balances (1) Prepared by R&D Division 1 Marketing Department A&D Company, Limited 1 Contents Things you should know before using a balance --------------------------- P.3 1. Convection

More information

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number 34320 Issue 4 Original Instructions (English)

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number 34320 Issue 4 Original Instructions (English) OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM Part Number 34320 Issue 4 Original Instructions (English) CONTENTS Part Numbers Covered by This Manual 2 Safety 2 Introduction 2 Parts Included 2 Accessories

More information

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar EUROLAB 25 years The role of metrology and testing to characterize materials and products April 9, 2015, Odense Danmark 1 Origin of Conformity Assessment The New Approach for the European Economic Community

More information

Measurement and Calibration

Measurement and Calibration Adapted from: H. A. Neidig and J. N. Spencer Modular Laboratory Program in Chemistry Thompson Learning;, University of Pittsburgh Chemistry 0110 Laboratory Manual, 1998. Purpose To gain an understanding

More information

Measuring instruments in industry.

Measuring instruments in industry. Measuring instruments in industry. Measuring instruments that are present in any branch of industry, are subject to different levels of supervision, like in case of laboratories. Supervision relates to

More information

Metrological assessment of micro flow-meters and drug delivery devices in the scope of the "MeDD" EMRP project

Metrological assessment of micro flow-meters and drug delivery devices in the scope of the MeDD EMRP project th 17 International Congress of Metrology, 09004 (2015) DOI: 10.1051/ metrolo gy/ 201509 00 4 C Owned by the authors, published by EDP Sciences, 2015 Metrological assessment of micro flow-meters and drug

More information

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (12) 77 7R QUALIFICATION OF EQUIPMENT ANNEX 8: QUALIFICATION OF BALANCES Full document title and reference Document type Qualification

More information

A Code of Practice for the Calibration of Industrial Process Weighing Systems

A Code of Practice for the Calibration of Industrial Process Weighing Systems A Code of Practice for the Calibration of Industrial Process Weighing Systems The Institute of Measurement and Control 87 Gower Street London WC1E 6AF WGC0496 Originally published 1996 Reviewed and re-issued

More information

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19 Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19 By Patricia DALMAS, Product Specialist, Radiometer Analytical Pharmaceutical laboratories working

More information

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

SWISS MADE. Series 320 XB MASTER. Analytical. Precision SWISS MADE MASTER Series Analytical Precision MASTER Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated

More information

www.kem-kueppers.com info@kem-kueppers.com

www.kem-kueppers.com info@kem-kueppers.com www.kem-kueppers.com info@kem-kueppers.com Calibration of flow meters according to DIN EN ISO/IEC 17025:2005 Introduction... 2 Calibration laboratory... 3 Description of the calibration process... 3 Calibration

More information

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK SWISS MADE Industrial Balances PREMIUM Series 490 IBK/ITK/ISK Precision Industrial Scales PREMIUM Series 490 IBK/ITK/ISK The Precisa 490 Series range of industrial scales stands for outmost Swiss precision.

More information

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING Test Procedure for VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR Texas Department of Transportation TxDOT Designation: Tex-901-K Effective Date: August 1999 1. SCOPE 1.1 All weighing devices shall

More information

American Association for Laboratory Accreditation

American Association for Laboratory Accreditation Page 1 of 5 INTRODUCTION ISO/IEC 17011 Conformity Assessment General requirements for accreditation bodies accrediting conformity assessment bodies, the standard by which A2LA operates in order to be recognized

More information

ROLE OF THE APEC SPECIALIST REGIONAL BODIES

ROLE OF THE APEC SPECIALIST REGIONAL BODIES ROLE OF THE APEC SPECIALIST REGIONAL BODIES ND A S ARD URE D N STA TRUCT E H F T FRAS O S NT NCE IN E M ELE FORMA CON Why is the Standards and Conformance Infrastructure important? ~ Improves everyday

More information

METRIC CONVERSION TABLE Multiply By To Obtain Millimetres 0.03937 Inches Millimetres 0.003281 Feet Metres 3.281 Feet Kilometres 0.

METRIC CONVERSION TABLE Multiply By To Obtain Millimetres 0.03937 Inches Millimetres 0.003281 Feet Metres 3.281 Feet Kilometres 0. Linear Measure Square Measure or Area Volume or Capacity Mass Density Force* Pressure* or Stress* Temperature METRIC CONVERSION TABLE Multiply By To Obtain Millimetres 0.03937 Inches Millimetres 0.003281

More information

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION International Document OIML 1 st CD GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION International Organization of Legal Metrology Contents 01 Scope 2 12

More information

(Uncertainty) 2. How uncertain is your uncertainty budget?

(Uncertainty) 2. How uncertain is your uncertainty budget? (Uncertainty) 2 How uncertain is your uncertainty budget? Paper Author and Presenter: Dr. Henrik S. Nielsen HN Metrology Consulting, Inc 10219 Coral Reef Way, Indianapolis, IN 46256 Phone: (317) 849 9577,

More information

How To Determine Uncertainty In A Source Stream

How To Determine Uncertainty In A Source Stream EUROPEAN COMMISSION DIRECTORATE-GENERAL CLIMATE ACTION Directorate A International and Climate Strategy CLIMA.A.3 - Monitoring, Reporting, Verification DRAFT Guidance Document The Monitoring and Reporting

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK code Coalville 6 Way North Cheshire Trading Estate Wirral CH43 3DU Contact: Mr D Williams Tel: +44 (0)151-649 9955 Fax: +44 (0)151-649 9977 E-Mail: sales@paragon-sci.com Website: www.paragon-sci.com Laboratory

More information

NIST Calibration Services for Liquid Volume NIST Special Publication 250-72

NIST Calibration Services for Liquid Volume NIST Special Publication 250-72 NIST Calibration Services for Liquid olume NIST Special Publication 250-72 ern E. Bean, Pedro I. Espina, John. D. Wright, John F. Houser, Sherry D. Sheckels, and Aaron N. Johnson March 24, 2006 Fluid Metrology

More information

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous

More information

Accreditation according to ISO/IEC 17025 in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

Accreditation according to ISO/IEC 17025 in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment Accreditation according to ISO/IEC 17025 in Europe Historic EA Europeing Accreditation Assessment Experience from Technical assessment 1 In year 1803 the foots in Europe had a big differences, depending

More information

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the

More information

JCGM 104:2009. Evaluation of measurement data An introduction to the Guide to the expression of uncertainty in measurement and related documents

JCGM 104:2009. Evaluation of measurement data An introduction to the Guide to the expression of uncertainty in measurement and related documents Evaluation of measurement data An introduction to the Guide to the expression of uncertainty in measurement and related documents Évaluation des données de mesure Une introduction au Guide pour l expression

More information

20099 Sesto San Giovanni (Ml) Italy. (MID) RichtIinie 2004/22/EG des Europaischen Parlaments und des

20099 Sesto San Giovanni (Ml) Italy. (MID) RichtIinie 2004/22/EG des Europaischen Parlaments und des Applicant: I.G.S. DATAFLOW S. r. I. Bauartprufzertifikat No. CHM10021 I 00800 Type examination certificate This document may not be published or forwarded other than in full. METAS Lindenweg 50, CH3003

More information

International Organization for Standardization

International Organization for Standardization International Organization for Standardization ISO 9001 What does it mean in the supply chain? Introduction As someone who is involved in the selection of suppliers and, possibly, responsible for purchasing

More information

MIKROS SYSTEMS TRAFFIC EVENT LOGGING. HSWIM Calibration Instruction TEL EQUIPMENT MS001-00006-56 ISSUE 3

MIKROS SYSTEMS TRAFFIC EVENT LOGGING. HSWIM Calibration Instruction TEL EQUIPMENT MS001-00006-56 ISSUE 3 MIKROS SYSTEMS TRAFFIC EVENT LOGGING HSWIM Calibration Instruction TEL EQUIPMENT MS001-00006-56 ISSUE 3 1 Table of content 1 Introduction... 3 2 Equipment Needed... 3 3 Methodology... 5 4 Interpretation

More information

Industrial gas meters G10, G16, G25, G40, G65

Industrial gas meters G10, G16, G25, G40, G65 Industrial gas meters G, G6, G5, G4, G65 Commercial Gas Meter G The gas meter AM-G is designed for gas is equivalent to 6m/h of air of density of, kg/m. Qmax = 6 m/h =, m/h Qn = m/h V = 5 dm Pmax =,5 bar

More information

Handbook of Weighing Applications Balances and Scales Used as Measuring and Test Equipment in a Quality System

Handbook of Weighing Applications Balances and Scales Used as Measuring and Test Equipment in a Quality System Handbook of Weighing Applications Balances and Scales Used as Measuring and Test Equipment in a Quality System turning science into solutions Preliminary Considerations In many areas of applications, the

More information

Density and Archimedes Principle

Density and Archimedes Principle Density and Archimedes Principle Objectives: To understand the concept of density and its relationship to various materials. To understand and use Archimedes Principle. Equipment: Dial calipers, Graduated

More information

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less 3A2 008 ISTA 3 Series General Simulation Performance Procedure VERSION DATE Last TECHNICAL Change: FEBRUARY 2008 Last EDITORIAL

More information

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document 74-461

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document 74-461 Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/0/202 Adapted from National Bureau of Standards Document 74-46 The purpose of calibrating glassware is to determine the volume of

More information

User checks and maintenance of laboratory balances

User checks and maintenance of laboratory balances Technical Note 13 March 2014 Issued: July 1995 Amended and reissued: July 2005, July 2007, October 2007, May 2010, March 2013, March 2014 User checks and maintenance of laboratory balances Copyright National

More information

01 The Nature of Fluids

01 The Nature of Fluids 01 The Nature of Fluids WRI 1/17 01 The Nature of Fluids (Water Resources I) Dave Morgan Prepared using Lyx, and the Beamer class in L A TEX 2ε, on September 12, 2007 Recommended Text 01 The Nature of

More information

Case study Realistic and best uncertainties with humidity instruments

Case study Realistic and best uncertainties with humidity instruments Case study Realistic and best uncertainties with humidity instruments Domen Hudoklin September 2014 Brdo, Slovenia Humidity calibrations Dewpoint primary - against dewpoint generator secondary - against

More information

NMI R 51 Automatic Catchweighing Instruments

NMI R 51 Automatic Catchweighing Instruments NMI R 51 Automatic Catchweighing Instruments (OIML R 51-1:1996(E), IDT and OIML R 51-2:1996(E), IDT) The English version of international standard OIML R 51:1996 Automatic Catchweighing Instruments is

More information

American Association for Laboratory Accreditation

American Association for Laboratory Accreditation Page 1 of 18 Traceability for Life Sciences Testing and (October 2015) 2015 by A2LA. All rights reserved. No part of this document may be reproduced in any form or by any means without the prior written

More information

The. Software Metrology of

The. Software Metrology of The Software Metrology of Opti Mu : More than just a software for measuring instruments management Stress-free audits Simple, fast measuring instrument management Compliance with ISO standards: 9001, 10012,

More information

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS Presented 2006 May 16-18 2006 ISFFM Queretaro, Mexico A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS P. Delajoud, M. Bair, C. Rombouts, M. Girard DH Instruments,

More information

General Physics 1. Class Goals

General Physics 1. Class Goals General Physics 1 Class Goals Develop problem solving skills Learn the basic concepts of mechanics and learn how to apply these concepts to solve problems Build on your understanding of how the world works

More information

Calibration of Glassware

Calibration of Glassware Calibration of Glassware Introduction Glassware is commonly calibrated using a liquid of known, specific density, and an analytical balance. The procedure is to determine the mass of liquid the glassware

More information

The Determination of Uncertainties in Charpy Impact Testing

The Determination of Uncertainties in Charpy Impact Testing Manual of Codes of Practice for the Determination of Uncertainties in Mechanical Tests on Metallic Materials Code of Practice No. 06 The Determination of Uncertainties in Charpy Impact Testing M.A. Lont

More information

Type examination certificate No. CH-MI001-09020-00 e Bauartprüfzertifikat

Type examination certificate No. CH-MI001-09020-00 e Bauartprüfzertifikat Confederation suisse Confederazlone SYlzzera Confederazlun syizra Federal Departement of Juslice and Police Fedenll Office of Metrology Certification Body METAS-Cert Type examination certificate No. CH-MI001-09020-00

More information

How To Test For Totalizing Weight

How To Test For Totalizing Weight Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Discontinuous totalizing automatic weighing instruments (totalizing hopper weighers) Part 1: Metrological and technical requirements

More information

Three Methods for Calculating the Buoyant Force Gleue: Physics

Three Methods for Calculating the Buoyant Force Gleue: Physics Three Methods for Calculating the Buoyant Force Gleue: Physics Name Hr. The Buoyant Force (F b ) is the apparent loss of weight for an object submerged in a fluid. For example if you have an object immersed

More information

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration? Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +46 33 22 56 30 Fax: +46 33 13 88 71 info@kalibrera.se www.kalibrera.se In May 2011 Elastocon purchased the company Mätcentrum in Eskilstuna,

More information

Uncertainty of Force Measurements

Uncertainty of Force Measurements European Association of National Metrology Institutes Uncertainty of Force Measurements EURAMET cg-4 Version.0 (03/011) Previously EA-10/04 Calibration Guide EURAMET cg-4 Version.0 (03/011) UNCERTAINTY

More information

EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa

EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa Final Report of EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa Yasin DURGUT 1 Nenad PETROVSKI 2 Vanco KACARSKI 2 (1) National Metrology Institute (UME),

More information

Nursing 131 Household to Metric Conversion

Nursing 131 Household to Metric Conversion Nursing 3 Household to Metric Conversion Slide 2 & 3 In the metric system liquid volumes are measured in milliliters or liters. Weight is measured in micrograms, milligrams, grams, or kilograms. liter

More information

(The opinion exchange between Turkey and EU is continuing. ) Regulation on installation of lighting and light-signaling

(The opinion exchange between Turkey and EU is continuing. ) Regulation on installation of lighting and light-signaling List of the Turkish Legislation harmonising the Old Approach Directives of the EU which has been sent to the EC Commission for its opinion Responsible Authority Undersecretariat of Foreign Trade Ministry

More information

AP Physics 1 and 2 Lab Investigations

AP Physics 1 and 2 Lab Investigations AP Physics 1 and 2 Lab Investigations Student Guide to Data Analysis New York, NY. College Board, Advanced Placement, Advanced Placement Program, AP, AP Central, and the acorn logo are registered trademarks

More information

OIML R 117-2 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 117-2 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 117-2 Edition 2014 (E) Dynamic measuring systems for liquids other than water. Part 2: Metrological controls and performance tests Ensembles de mesurage dynamique de

More information

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35 Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013

More information

Summary of Requirements for ISO 14001:2004 February 24, 2005

Summary of Requirements for ISO 14001:2004 February 24, 2005 Summary of Requirements for ISO 14001:2004 February 24, 2005 This document provides a summary of the requirement of ISO 14001:2004, which is an international standard describing the specification and requirements

More information

Higher Education Institutions in Switzerland

Higher Education Institutions in Switzerland Higher Education Institutions in Switzerland Higher education institutions (HEI) in Switzerland comprise two equivalent establishments with different tasks: universities and universities of applied sciences.

More information

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT. September 1, 2003 CONCRETE MANUAL 5-694.300 MIX DESIGN 5-694.300 NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT. 5-694.301

More information

Inventory management within a food factory

Inventory management within a food factory Inventory management within a food factory Daniela Magdalena DINU Ph.D. Student, University of Economic Studies, Bucharest, Romania e-mail: danielapopa74@yahoo.com ABSTRACT An efficient management of inventories

More information

Regulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector

Regulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector Regulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector 57th LCA Discussion Forum 2 December 2014 Andreas J.

More information

General and statistical principles for certification of RM ISO Guide 35 and Guide 34

General and statistical principles for certification of RM ISO Guide 35 and Guide 34 General and statistical principles for certification of RM ISO Guide 35 and Guide 34 / REDELAC International Seminar on RM / PT 17 November 2010 Dan Tholen,, M.S. Topics Role of reference materials in

More information

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications Contents - Requirements in OIML publications - Uncertainty effects on trade - Back

More information

OIML R 106-1 RECOMMENDATION. Edition 2011 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 106-1 RECOMMENDATION. Edition 2011 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 106-1 Edition 2011 (E) Automatic rail-weighbridges Part 1: Metrological and technical requirements - Tests Ponts-bascules ferroviaires à fonctionnement automatique.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 18852 Third edition 2015-06-01 Rubber compounding ingredients Determination of multipoint nitrogen surface area (NSA) and statistical thickness surface area (STSA) Ingrédients

More information

SUPPLIER QUALITY PROGRAM, V (U)

SUPPLIER QUALITY PROGRAM, V (U) FEDERAL MANUFACTURING & TECHNOLOGIES PQR 1060 PAGE 1 OF 17 SUPPLIER QUALITY PROGRAM, V (U) CHANGE HISTORY ISSUE DESCRIPTION OF CHANGE AUTHOR DATE E CORRECTED CHANGE HISTORY S. L. HALTER 10/18/2000 F UPDATED

More information

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES Prepared by: Technical Manager Approved by: Chief Executive Officer Approval Date: 2013-04-24 Effective

More information

Guidelines on the Calibration of Static Torque Measuring Devices

Guidelines on the Calibration of Static Torque Measuring Devices European Association of National Metrology Institutes Guidelines on the Calibration of Static Torque Measuring Devices EURAMET cg-14 Version.0 (03/011) Previously EA-10/14 Calibration Guide EURAMET cg-14

More information

APPENDIX B. The Risk Pool Game B.1 INTRODUCTION

APPENDIX B. The Risk Pool Game B.1 INTRODUCTION APPENDIX B The Risk Pool Game B.1 INTRODUCTION One of the most important concepts in supply chain management is risk pooling. Recall that risk pooling involves the use of centralized inventory to take

More information

Michelin Luxembourg SCS. Société en Commandite Simple. Audited annual accounts for the year ended December 31, 2010

Michelin Luxembourg SCS. Société en Commandite Simple. Audited annual accounts for the year ended December 31, 2010 Société en Commandite Simple Audited annual accounts for the year ended December 31, 2010 69, Boulevard de la Pétrusse L-2320, Luxembourg R.C.S. - B96.546 Declarations COMPAGNIE FINANCIERE MICHELIN, a

More information