Series description: Wilo-Star-Z
|
|
- Tiffany Flynn
- 7 years ago
- Views:
Transcription
1 H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry and building services. Ce circulateur convient seulement pour l'eau potable. Type key Example: Wilo-Star-Z 2/1Wilo-Star-Z 15 TT Star Standard pump Z Circulation pump 2/ Nominal connection diameter 1 Nominal delivery head [m] TT with built-in time switch and temperature control (only Z 15 TT) EM AC motor (1~) DM Three phase motor (3~) -3 3 speed stages Special features/product advantages AC pumps with electrical quick connection All plastic parts that come into contact with the fluid fulfil KTW recommendations Thermal insulation as standard for StarZ 15 TT. Star-Z 15 TT with integrated timer and thermostat, LC display with symbolic language, red button technology and automatic detection of the thermal disinfection of the warm secondary hot water tank, as well as ball shut-off valve on the suction side and non-return valve on the pressure side. Technical data Constant speed or, for StarZ...-3, three selectable speed stages Fluid temperature: Potable water up to 3.21 mmol/l (18 dh): max. +65 C, in shortterm operation (2 h) up to +7 C Mains connection 1~23 V, 5 Hz or, for StarZ 25/2 DM, 3~4 V, 5 Hz Protection class IP 44 (IP 42 for Star-Z 15 TT) Nominal diameter Rp ½, Rp 1 Max. operating pressure 1 bar Subject to change without prior notice. Star -Z 2 Sta /7 r-z 25/ 6 Star-Z Star -Z 2 5/2 DM Z 25 /2 E M Star- T,5 Z 2 / Q[m³/h] Equipment/function Operating modes Speed stage switching (StarZ -3 only) Manual functions Setting of the speed stages (1 speed stage, 3 speed stages with StarZ...-3 pumps) Automatic functions Time switching function for programming of 3 switch-on or switch-off times (Z 15 TT only) Temperature control for maintaining a constant return temperature in the secondary hot water circulation system (Z 15 TT only) Thermal disinfection routine (detection and support of thermal disinfection of the warm secondary hot water tank) (only Z 15 TT) Blocking protection (only Z 15 TT) Signal and display functions LCD screen for display of pump data and fault codes (Z 15 TT only) Equipment Wrench attachment point on the pump body (StarZ 25 only) Cable inlet possible from both sides (StarZ 2/..., StarZ 25/... only) Quick connection with spring clips Blocking current-proof motor Integrated non-return valve on the pressure side (only Star-Z 15 TT) Integrated ball shut-off valve on suction side (only Star-Z 15 TT) Including time switch (only Z 15 TT) Materials Pump housing: Brass: Star-Z 15 Bronze: StarZ 2, Z 25 Impeller: Plastic Shaft: Stainless steel: Star-Z 15 Oxide ceramic: StarZ 2, Z 25 Bearing: Carbon, synthetic resin impregnated Scope of delivery Pump Including seals for threaded connection Including installation and operating instructions Including thermal insulation (Star-Z 15 TT only) Accessories Screwed connections Adapter fittings Thermal insulation shells for Star-Z 2, 25 Special brass inserted parts for screw-end pumps: Male thread/inner soldering connection WiloS1Rh switchgear plug-in module for StarZ 2/1, Z 25/2 EM (singlephase version) WiloSK 61N switchgear in connection with WiloSK 62N (as contactor) for StarZ 25/2 DM (three-phase version) 5 Hz EU / 18
2 Series description: Wilo-Star-Z WiloSK 61N switchgear for timed On/Off switching for StarZ 2, 25 Subject to change without prior notice. 5 Hz EU / 18
3 Data sheet: Wilo-Star-Z 15 TT Pump curves Single-phase current H[m] 1,,8,1,2,3,4,5,6 Star-Z 15 TT Wilo-Star-Z 15 TT 1~23 V - Rp ½ [m/s] Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked),6,4,2,5,1,15,2,25,3 Q[m³/ h],2,4,6,8 Q[l/s],2,4,6,8 1, Q[Igpm] P 1 [W] ,5,1,15,2,25,3 Q[m³/ h] Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) Permitted field of application temperature of +25 C temperature +4 C Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C C Dimension drawing A ,35 126,4 8,4 5 Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 77 Maximum permissible operating pressure Pipe connections P max 1 bar Terminal diagram 1~23 V Threaded pipe union Rp ½ Thread G 1 Overall length L 138 mm Motor/electronics Emitted interference EN L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Interference resistance EN Protection class IP 42 Insulation class F Mains connection 1~23 V, 5 Hz Speed range n rpm Power consumption P 1 max. 22 W Current consumption I max..25 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
4 Data sheet: Wilo-Star-Z 15 TT Threaded cable connection PG 1x9 Materials Pump housing Impeller Pump shaft Bearing Brass (CuZn4Pb2) Plastic (PPO) Stainless steel (X35CrMo17) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C.5 / 2 / m Information for order placements Make Type Wilo Star-Z 15 TT Art no Weight approx. m 2.33 kg Subject to change without prior notice. 5 Hz EU / 18
5 Data sheet: Wilo-Star-Z 2/1 Pump curves Single-phase current 1,2 1,,8 v,5 1, [m/s] Wilo-Star-Z 2/1 1 ~ 23 V Rp½ Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) H [m],6,4 Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance),2 Permitted field of application 5,25,5,75 1, 1,25 1,5,1,2,3, Q [m 3 /h] [l/s] [lgpm ] temperature of +25 C temperature +4 C P 1 [W] Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C C 1,25,5,75 1, 1,25 1,5 Dimension drawing [m 3 /h] Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 14 Maximum permissible operating pressure P max 1 bar 7 78 Pipe connections G 1 93, Threaded pipe union Rp ½ Thread G 1 Overall length L 14 mm Terminal diagram 1~23 V Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Insulation class F Mains connection 1~23 V, 5 Hz Speed range n rpm Power consumption P W Current consumption I max..18 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
6 Data sheet: Wilo-Star-Z 2/1 Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 499K) according to DIN in accordance with Drinking Water Ordinance Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C.5 / 3 / 1 m Information for order placements Make Wilo Type Star-Z 2/1 Art no Weight approx. m 2.24 kg Subject to change without prior notice. 5 Hz EU / 18
7 Data sheet: Wilo-Star-Z 25/2 EM Pump curves Single-phase current H [m] 4, 3,5 3, 2,5 2, 1,5 1,,5 8,5,5 v 1, 1, 1,5 2, 2,5 3, 3,5 [m 3 /h],25,5 2,5 5, 7,5 Q 1,5,75 1 [m/s] Wilo-Star -Z 25/2 1 ~ 23 V Rp 1 1, [l/s] 12,5 [lgpm ] Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) Permitted field of application temperature of +25 C temperature +4 C P 1 [W] 6 4 Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C C 2,5 1, 1,5 2, 2,5 3, 3,5 Dimension drawing [m 3 /h] Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 18 Maximum permissible operating pressure P max 1 bar 9 78 Pipe connections G 1½ 93, Threaded pipe union Rp 1 Thread G 1½ Overall length L 18 mm Terminal diagram 1~23 V Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Insulation class F Mains connection 1~23 V, 5 Hz Speed range n rpm Power consumption P 1 max. 46 W Current consumption I max..22 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
8 Data sheet: Wilo-Star-Z 25/2 EM Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 499K) according to DIN in accordance with Drinking Water Ordinance Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C.5 / 3 / 1 m Information for order placements Make Type Wilo Star-Z 25/2 EM Art no Weight approx. m 2.44 kg Subject to change without prior notice. 5 Hz EU / 18
9 Data sheet: Wilo-Star-Z 25/2 DM Pump curves Three-phase current H [m ] 4, 3,5 3, 2,5 2, 1,5 1,,5 1,5,5 v 1, 1, 1,5 2, 2,5 3, 3,5 [m 3 /h],25,5 2,5 5, 7,5 Q 1,5,75 1 [m/s] Wilo-Star -Z 25/2 3 ~ 4 V Rp 1 1, [l/s] 12,5 [lgpm ] Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) Permitted field of application temperature of +25 C temperature +4 C P 1 [W] 8 6 Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C C 4,5 1, 1,5 2, 2,5 3, 3,5 Dimension drawing [m 3 /h] Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 18 Maximum permissible operating pressure P max 1 bar 9 78 Pipe connections G 1½ 93, Threaded pipe union Rp 1 Thread G 1½ Terminal diagram 3~4 V PE L1 L2 L3 Overall length L 18 mm Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 Insulation class F Three-phase AC motor (DM), 2-pole- 3~4 V, 5 Hz Mains connection 3~4 V, 5 Hz Speed range n rpm Power consumption P W Current consumption I max..16 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
10 Data sheet: Wilo-Star-Z 25/2 DM Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 499K) according to DIN in accordance with Drinking Water Ordinance Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C.5 / 3 / 1 m Information for order placements Make Type Wilo Star-Z 25/2 DM Art no Weight approx. m 2.62 kg Subject to change without prior notice. 5 Hz EU / 18
11 Data sheet: Wilo-Star-Z 25/6-3 Pump curves Single-phase current P 1 [W] H [m] [m 3 /h],25,5,75 1 1,25 [l/s] 2,5 5 7,5 1 12,5 15 Q v,5 1, 1,5 2, 2,5 [m/s] min min max. Wilo-Star-Z 25/6 1 ~ 23 V - Rp Dimension drawing Pg 11 G 1½ max. [lgpm] [m 3 /h] Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) Permitted field of application temperature of +25 C temperature +4 C Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h C T 7 C 9 79 Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 18 Maximum permissible operating pressure P max 1 bar 78 Pipe connections 93, Threaded pipe union Rp 1 Thread G 1½ Terminal diagram 1~23 V Overall length L 18 mm Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Insulation class F Mains connection 1~23 V, 5 Hz Speed range n rpm Power consumption P 1 49 / 74 / 99 W Current consumption I A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
12 Data sheet: Wilo-Star-Z 25/6-3 Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 499K) according to DIN in accordance with Drinking Water Ordinance Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C.5 / 3 / 1 m Information for order placements Make Wilo Type Star-Z 25/6-3 Art no Weight approx. m 2.66 kg Subject to change without prior notice. 5 Hz EU / 18
13 Data sheet: Wilo-Star-Z 2/4-3 Pump curves Single-phase current 5 4 v,5 1, 1,5 2, [m/s] Wilo-Star-Z 2 / 4 1~23 V - 5Hz Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) H [m] 3 2 Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) 1 max. Permitted field of application P 1 [W] 1, 2, 3, [m 3 /h],25,5,75 1, [l/s] min. Q min. max. temperature of +25 C temperature +4 C Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C C C 2 1, 2, 3, [m 3 /h] Dimension drawing Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 15 Maximum permissible operating pressure P max 1 bar Pipe connections Threaded pipe union Rp ½ G 1¼ 93, Thread G 1¼ Overall length L 15 mm Terminal diagram 1~23 V Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 Insulation class F L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Mains connection 1~23 V, 5 Hz Speed range n rpm Power consumption P W Current consumption I max..31 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
14 Data sheet: Wilo-Star-Z 2/4-3 Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 491K) according to DIN in accordance with Drinking Water Ordinance) Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C / 3 / 1 m Information for order placements Make Wilo Type Star-Z 2/4-3 Art no Weight approx. m 2.36 kg Subject to change without prior notice. 5 Hz EU / 18
15 Data sheet: Wilo-Star-Z 2/5-3 Pump curves Single-phase current 5 4 v,5 1, 1,5 2, 2,5 [m/s] Wilo-Star-Z 2 / 5 1~23 V - 5Hz Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) H [m] 3 2 Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) 1 max. Permitted field of application P 1 [W] 1, 2, 3, 4, [m 3 /h],25,5,75 1, 1,25 [l/s] min. 2 1, 2, 3, 4, [m 3 /h] Dimension drawing Q min. 13 max. temperature of +25 C temperature +4 C Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C C C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 15 Maximum permissible operating pressure P max 1 bar Pipe connections Threaded pipe union Rp ½ G 1¼ 93, Thread G 1¼ Overall length L 15 mm Terminal diagram 1~23 V Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 Insulation class F L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Mains connection 1~23 V, 5 Hz Speed range n 2-26 rpm Power consumption P W Current consumption I max..4 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
16 Data sheet: Wilo-Star-Z 2/5-3 Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 491K) according to DIN in accordance with Drinking Water Ordinance) Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C / 3 / 1 m Information for order placements Make Wilo Type Star-Z 2/5-3 Art no Weight approx. m 2.51 kg Subject to change without prior notice. 5 Hz EU / 18
17 Data sheet: Wilo-Star-Z 2/7-3 Pump curves Single-phase current P 1 [W] H [m] , 2, 3, 4,,4,8 1, , 2, 3, 4, 5, [m 3 /h] v,5 1, 1,5 2, 2,5 3, [m/s] Dimension drawing min. min. Q Wilo-Star-Z 2 / 7 1~23 V - 5Hz 13 max. 5, [m 3 /h] [l/s] max. Approved fluids (other fluids on request) Heating water (in accordance with VDI 235) Water-glycol mixtures (max. 1:1; above 2% admixture, the pumping data must be checked) Potable water and water for foodprocessing companies in accordance with TrinkwV 21 (drinking water ordinance) Permitted field of application temperature of +25 C temperature +4 C Temperature range for applications in secondary hot water circulation systems at maximum ambient temperature of +4 C Temperature range for applications in secondary hot water circulation systems at max. ambient temperature of +4 C in short-term operation 2 h T 7 C C C PG Max. permitted total hardness in potable water circulation systems 3.21 mmol/l (18 dh) 15 Maximum permissible operating pressure P max 1 bar G 1¼ 93, Pipe connections Threaded pipe union Thread Rp ½ G 1¼ Overall length L 15 mm Terminal diagram 1~23 V Motor/electronics Emitted interference EN Interference resistance EN Protection class IP 44 L N PE Blocking current-proof motor Single-phase motor (EM) 2pole 1~23 V, 5 Hz With built-in capacitor Insulation class F Mains connection 1~23 V, 5 Hz Speed range n 2-27 rpm Power consumption P W Current consumption I max..65 A Motor protection Not required (blocking-current proof) Subject to change without prior notice. 5 Hz EU / 18
18 Data sheet: Wilo-Star-Z 2/7-3 Threaded cable connection PG 1x11 Materials Pump housing Impeller Pump shaft Bearing Red brass (CC 491K) according to DIN in accordance with Drinking Water Ordinance) Plastic (PPO) Oxide ceramic, brown (Al2O3) Carbon, synthetic resin impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 4 / 65 / 11 C / 3 / 1 m Information for order placements Make Wilo Type Star-Z 2/7-3 Art no Weight approx. m 2.9 kg Subject to change without prior notice. 5 Hz EU / 18
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
More informationSeries description: Wilo-Yonos MAXO-D
ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More information1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]
Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationCatalogue Wilo- Stratos PARA
Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationMultistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
More information2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationLaing industrial pumps
Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationV5001S. Kombi-S Shutoff Valve. Product specification sheet
V5001S Kombi-S Shutoff Valve Product specification sheet Application The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It
More information1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4
Henco Snelselectie kaart EN IMPORTANT! Before starting work the fitter must carefully read this installation and operation manual, understand and observe its conditions. The water floor heating control
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationProduct Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz
Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationHeating, Air-conditioning, Cooling
Catalogue Building Services Heating, Air-conditioning, Cooling Pumps, pump systems and accessories for heating, secondary hot water, air-conditioning and cooling International edition 2011/2012-50 Hz APPLIES
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationLC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
More informationOperating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationOverview of types. Technical data
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationLK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationSafety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationThe conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationGlobo P. Ball valves Pump ball valve made of gunmetal
Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationClinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
More informationFLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES
01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection
More informationReplacement Guide Heating
Replacement Guide Heating Wilo Circulators for Heating and Secondary Hot Water Circulation ab 1975 September 2006 Energy efficiency class A. Also for one- and two-family homes. Up to 80 % power savings.*
More informationButterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationV1810. Alwa-Kombi-4 Circulation throttle valve. Product data
V1810 Alwa-Kombi-4 Circulation throttle valve Product data Alwa-Kombi-4 with internal threads Design The Alwa-Kombi-4 valve consists of: Valve housing in straight pattern with internal threads to ISO 7
More informationHEAT INTERFACE UNITS (Modular)
HEAT INTERFACE UNITS The Rhico T Fire Modular is probably the most versatile HIU available, the basic unit is a indirect heating only module incorporating a circulation pump on the secondary circuit. (A
More informationInstallation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
More informationCALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB
SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production SATK20 - SATK30 series ACCREDITED CALEFFI 01209/13 GB ISO 9001 FM 21654 ISO 9001 No. 0003 The latest generation heat
More informationSIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES
OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm
More informationINLINE SD-PUMPS WITH IEC-STANDARD MOTOR
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationTestomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance
Data sheet DS/AW00 EN Rev. D Testomat AW0 Water Hardness Monitor A unique water hardness monitoring system with superior performance Automatic on-line monitoring of residual/total water hardness ideal
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More information1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationVertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
More informationservo-controlled 3-WaY vacuum solenoid valves WiTH
servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationHeating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationB MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationOperating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1
Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1 General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit
More informationPS1800 Centrifugal Pumping Systems
PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationDescription of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More information