Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Similar documents
Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring function

Belimo Gateway MP to Modbus RTU - UK24MOD

User's Guide. CTS6000 WebControl

PC Software for VAV compact and modular controllers

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

HERZ-Thermal Actuators

VAV system solution for non-pressure-dependent applications in enclosed spaces

Online Help choise of topic

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Spyglass Portal Manual v

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

USER S MANUAL. AXIS Mobile Monitor

F453. TiF453. User guide 10/11-01 PC

Heating, air-conditioning, cooling

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

evohome Wireless Radiator Zoning Kit Installation & User Guide

Uponor Smatrix Wave PLUS R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

ABB solar inverters. User s manual ABB Remote monitoring portal

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Solar Tracking Controller

AxxonSoft Inc. Axxon Smart. Quick Start Guide. AxxonSoft. The. Axxon Smart. Software Package. Quick Start Guide. Version 1.0

AMTRON E-30 Compact heat and cooling meter

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Electronic Pressure Switch EDS 300

Series DFMT Digital Paddlewheel Flowmeter

Contents. Introduction

NAS 253 Introduction to Backup Plan

ABB solar inverters. User s manual ABB Remote monitoring portal

SNMP Web Management. User s Manual For SNMP Web Card/Box

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Monitoring Network DMN

Counter for Energy. We make energy measurable and secure your future.

The service note describes the basic steps to install a ip camera for the DVR670

Workshop 7 PC Software - Tracker

SecureLinx Spider Duo Quick Start Guide

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Totally Internet Based Software. User Entry. Strategy Systems, Inc. PO Box 2136 Rogers, AR (479)

Setting up the Swann HD IP cameras

Tebis application software

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Web Page Manual. GOLD RX, PX, CX, SD, Program Version 1.20

HP ProLiant ML150 System Monitor User Guide

for Windows Media Center User's Guide

Hydraulic Control Solutions

- 1 - SmartStor Cloud Web Admin Manual

IMAP and SMTP Setup in Clients

T-100-R Installation Guide

NAS 243 Using AiData on Your Mobile Devices

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Installing The Monitoring Software

TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator. A tutorial prepared for IE 575 by Dr. T.C. Chang. Use On-Line Help

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

CleanOpsStaff 3ed ProMobile PDA Manager Help Updated 9/1/2011 (Recommend you print out this file)

NAS 103 Wake-on-LAN (WOL) Set up and use WOL with your ASUSTOR NAS

User manual Business Voice Digital Phone START + PRO

Medical Vacuum Systems-PXMI

1 QPro HelpFile 01.EN COPYRIGHT CONTRIVE

Standalone recorder instruction

Metering for today s systems

Olson Electronics Remote Power Monitoring Meter

REGTRONIC OPERATING INSTRUCTIONS

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

Mississippi Educator Licensure Management System. Single Sign On User Guide

VFS24/32HDIP. Public Display IP Monitor User Manual

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

DOMUSBOX. User guide. Index

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Administering Cisco ISE

D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL

Measuring, Controlling and Regulating with labworldsoft

User s Manual of DVR DVS Remote Client Software V 4.0.1

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

PXM20-E. Operator unit DESIGO PX

Maintaining the Content Server

Actuator for modulating control AME 435

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Demo of Data transferring (.CSV Files) from EGX300 to Our local PC/Laptop using- FTP

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Tera Term Telnet. Introduction

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

CRE Monitor Instructions Manual

USER GUIDE. Web Interface

IntelliTouch Remote Control & Monitor for Service Professionals. User s Guide. ScreenLogic Wireless Connection Kit Installation Guide

NVMS User Manual

Instruction Manual IM/LM_3. Field IT. Data Capture Utility. LogMaster

Pogo> User Guide. for iphone, ipad and ipod touch

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

ZyXEL IP PBX Support Note. ZyXEL IP PBX (X2002) VoIP. Support Notes

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

Temperature controller for heated/chilled ceiling systems

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Transcription:

Belimo Energy Valve TM web server manual P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Contents General 2 3 Attachment 11 www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 1 / 11

Characterised control valve (CCV) with adjustable flow rate and sensor-operated flow control, and power and energy-monitoring General Access to the Energy Valve Connect the PC/Laptop to the Energy Valve with the RJ45 cable Open Internet Explorer and enter the following address: http://192.168.0.10:8080 If the IP address is changed, Belimo will not be able to reset it. 192.168.0.10 is the IP address assigned at the time of delivery Note: The Energy Valve must be supplied with voltage. User name and password Access to the Energy Valve is password-protected 3 users have different reading and writing access Legend: L = Read access S = Write access - = Page is not displayed 1) = Please contact your Belimo Representative 2 / 11 T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes www.belimo.com

General General information regarding operation A brief display of a value against a green background indicates that this value has changed Changing settings: When a new setting is selected (dropdown menu), it will be applied automatically A new value is applied automatically after it has been entered and the ENTER key has been pressed. It is not necessary to press a 'Save' button. Dashboard After entry, the dashboard displays an overview of the most important ACTUAL values The navigation option for accessing the other pages is to be found on the left-hand side of the monitor Overview In addition to the most important ACTUAL values, this page also shows the heating/cooling energy that has been consumed and the current NOMINAL values. www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 3 / 11

Overvride and Live Trend The current positioning signal can be overridden with the help of the Override function. The following options are available: o Auto: No manual override o Close: Valve is closed o Open: Valve is opened completely o Vnom: The nominal flow rate of the valve (catalogue value) is controlled 1) o Vmax: The set maximum volumetric flow (100% requirement) is controlled o Motor stop: The actuator remains at its current position o Setpoint pos. override: Regulation of a volumetric flow totaling X% of Vmax Enter percentage value! o Setpoint Simulation: Observation of the connection between control signal [V] and set flow rate characteristic (linear or equal percentage) Enter voltage [V]! 1) As Vnom may be greater than the maximum required (set) Vmax of the installation, achieving the nominal volumetric flow Vnom is dependent on the output of the pump. The override function is deactivated automatically after 2 hours. The time remaining before deactivation is displayed. The Live Trend function shows the valve values since entry/login and first clicking on "Override and Live Trend". The displayed values can be selected in the lower range. 4 / 11 T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes www.belimo.com

Settings All settings can be made on this page. Settings - Application Valve size o DN65 to DN150 The setting of the valve size may not be changed! The setting of the cable lenght may not be changed! Installation position The correct setting is important for the allocation of the consumed energy as colling or heating energy o ->: Valve installed in the supply line of the heat exchanger o <-: Valve installed in the return of the heat exchanger Medium Selection of the medium used: o Water o Monoethylene glycol o 1.2 polypropylene glycol Concentration o Percentage concentration of the glycol Cable length o The cable length of the sensor which is away from the valve is setted to the correct value of 10 meters ex works. Settings - User Setting the desired language and value units Language Power English (*) W German kw (*) Temperature BTU/h C (*) kbtu/h F Ton Flow rate Energy m 3 /h kwh (*) l/s MWh l/min (*) kbtu l/h TonH GPM (*) = presetting ex-works www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 5 / 11

Settings Control function configuration Parameterisation of the analogue positioning signal Y o Control strategy Pos. control: In this setting, the valve functions as a pressure-dependent valve, e.g. like a conventional characterised control valve Flow control: Operation as a pressureindependent valve analogous to an EPIV o Control signal range 0.5 10V DC 2 10V DC o Control signal inversion -: no inversion 0V = valve closed / 10V = valve open yes: inversion 10V = valve closed / 0V = valve open o Control signal characteristic equal percentage: equal-percentage characteristic curve linear: linear characteristic curve Settings Flow rate configuration Maximum flow rate V'max o This value is to be set on the basis of the design data of the consumer o Recommended setting range: 45 100 of V'nom 1) o (Possible setting range: 30 100 of V'nom 1) ) 1) Vnom = nominal flow rate (catalogue value) Rescale the flow rate display o This function is used in order to align the flow rate value output by the Energy Valve via feedback signal U5 to the flow rate value measured by an external measuring device. o For more details and to obtain the activation code, please contact your Belimo representative. Settings Temperature configuration This function is used in order to suppress a power/energy calculation at low differential temperatures. Permissible range: 0 2 C Factory setting: 0 C 6 / 11 T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes www.belimo.com

Settings Configuration limitation This function can be used in order to prevent an increase in the volumetric flow when levels fail to reach a set supply/return differential temperature. The valve will not be opened further in such cases, even with an increasing positioning signal Limitation function o -: Delta T limitation switched off o Delta T: Delta T limitation switched on Limit: No increase in the volumetric flow when levels fall below this setting value Min. flow rate with flow rate control: In the case of operation as a pressure-independent valve, the differential temperature is not controlled up to the adjusted flow rate (percentage of V'max). Allowable input value: 30 100% Min. valve opening with position control: In the case of operation as a pressure-dependent valve, the differential temperature is not controlled up to the adjusted opening angle (percentage). Allowable input value: 30 100% The limitation function is not active so long as a valid value has been entered in the input fields - Min. flow for flow control (when control mode 'Flow control' is selected) or - Min. valve angle for pos. control (when control mode 'Pos. control' is selected) Settings Feedback function configuration Feedback Information: U5 corresponds to one of the following values. The units correspond to the units set in the 'User' range. o Flow: Flow rate o Power: Current consumer power o T supply: Supply temperature o T return: Return temperature o Delta T: Differential temperature, supply and return o Valve Position: Valve opening angle [ ] Feedback signal range: o 0 10V DC o 0.5 10V DC o 2 10V DC Upper limit selection: Setting the maximum value for the feedback signal 10V = set value Lower limit selection (only for T Supply, T Return): Setting the minimum value for the feedback signal o 0V = set value o Only when 'T supply' or 'T return' has been selected o 0V corresponds to the value 0 with all other selections www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 7 / 11

Status Display of the current error messages and the error history Current error messages are presented on the left-hand side The error history is displayed on the right-hand side The error history can be reset by users with the respective authorisation. Mobile For access with a view optimised with a smartphone 8 / 11 T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes www.belimo.com

Date & Time settings Possible settings: Date, Time and Time Zone Local Client: Date and time of the connected PC Remote Node: Date and time which is set on the Energy Valve Synchronize Time: Clicking on "Synchronize Time" causes the Date and Time settings of the attached PC (Local Client) to be adopted on the Energy Valve (Remote Node). When using several Energy Valve it is possible to define one Energy Valve as the Time- Master. Fot this purpose the IP address of the Time-Master must be entered at all other Energy Valves. IP Settings IP Settings www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 9 / 11

Version Information Display of the current software and hardware version Data Logging Download of the csv files stored in the Energy Valve Short Term Storage: One file is available per day for the last 7 days. A measurement series is stored every 30 seconds. Long Term Storage: One file is available per month for the last 13 months. A measurement series is stored every 2 hours. Deleted data cannot be restored! The files on the actuator can be deleted by users with the respective authorisation. 10 / 11 T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes www.belimo.com

BACnet/MP Settings Selection of the communication protocol o BACnet IP o BACnet MS/TP o MP o None (conventional control) Perform all relevant settings in accordance with the specifications of the onsite equipment. Logout Exiting the web server Attachment Definition of V'nom Is the maximum possible flow rate and corresponds to approximately 2 to 2.4 m/s medium velocity in the connection pipe with the same DN size. (For DN 65, the crosssection is approximately 0.065 m2 x Pi /4 = 0.0033 m2 and for 2.4 m/s medium velocity, this results in 480 L/min or 28.8 m3/h) Definition of V'max Is the maximum flow rate which has been set with the greatest positioning signal (10V). The V'max can be set to between 45% and 100% of the V'nom. www.belimo.com T5-Webserver P6...W..EV-BAC en v1.2 03.2013 Subject to changes 11 / 11