Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC
|
|
|
- Gwen McCormick
- 10 years ago
- Views:
Transcription
1 Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC
2 Advantages of Packaged Systems Grundfos integrated packaged pumping systems are factory-designed for optimized pumping and simplified installation. The advantages include: Single point responsibility Controls are optimized to application Better overall pumping efficiency Pretested at the factory as a complete pump system Implementing communication is easier and less costly Smaller footprint Less risk / liability Easy to install Lower installed cost HVAC applications are demanding more in terms of control and energy sustainability. Grundfos Hydro MPC has a solution with optimized control to meet challenging HVAC applications. The available control modes are: Differential pressure Proportional differential pressure Constant temperature Differential temperature Constant flow rate Constant pressure Proportional pressure
3 Simplify your System Comparison between Hydro MPC system and field built end suction pumps PACKAGED HYDRO MPC 3-PUMP SYSTEM: One housekeeping pad, no grouting No suction diffusers or triple duty valves One set of expansion joints (optional) One electrical connection No shaft/coupling alignments, adjustments Integrated controls Pretested at factory as complete system FIELD BUILT END SUCTION PUMPS: Two housekeeping pads, grouting Two inertia basis Two suction diffusers, triple duty valves, isolation valves Two sets of expansion joints Two VFD s mount and install Two electrical connections ( to VFD s and to pumps ) Two laser alignments, adjustments Gauges / sensors / etc. Field built controls Simplified! COMMON ISSUES ASSOCIATED WITH FIELD BUILT PUMPING SYSTEMS: Coordination between responsible parties Control issues Compatibility Communication Cost of labor Space
4 Perfecting your energy responsibility throughout the entire flow range H (ft) % % 200 Three pump efficiency curve Pump(s) Efficiency (%) Increased pumping efficiency area Single pump efficiency curve Higher efficiency with 3-pump system 0 Q(US gpm) Typically, the maximum designed flow is only required for a small percentage of time. High efficiency in part-load conditions is key to saving energy cost.
5 Expect increased efficiency through advanced controls THE BRAINS OF THE SYSTEM The highly advanced MPC control unit is the brain behind our Hydro MPC systems. Specially designed for control of parallel connected pumps, the MPC is easy to operate and monitor. Grundfos has used its experience with pump system controls to design the operation platform and control functions of the MPC to suit a wide range of application types. The result is a highly advanced control system that offers multiple features and functions that can be used to improve the performance of the pump system while maintaining a user-friendly operator interface. OPTIMAL NUMBER OF PUMPS RUNNING The method of evaluating the number of pumps that should be running is unique in the Hydro MPC. The pump curve data loaded into the controller ensures that the system can determine an estimated flow rate very precisely. The curves also make it possible to calculate the optimal start speed of the pumps. It can therefore stop or start an extra pump, while being as energy effective as possible while maintaining energy efficiency. the defined duty range. It is also possible to set a relay output to be activated when the warning is given, and deactivated when the warning is reset. DATA COMMUNICATION The MPC is set up for various communication systems to help you monitor and control the unit from a distance. Ethernet via built-in web server Bacnet, Lon, Modbus, Profibus LOG AND STATISTICS For full optimization of the pump system, it s important to ensure that valid operation data is obtained and continuously logged. The Grundfos MPC control offers easy access to a wide range of operating data and statistics, such as: Built-in logging capability System performance Energy consumption Alarm and warning log PROPORTIONAL PRESSURE FUNCTION The proportional pressure function gives the Hydro MPC the ability to increase setpoint pressure at higher flow rates and reduce the setpoint at lower flow rates. The pump curve data loaded into the controller gives the controller the ability to continuously estimate the flow rate so no flow meter is required for the proportional pressure function. PUMP OUTSIDE DUTY RANGE Pump curve data loaded into the controller makes it possible to determine the location of the pumps on the curve. This function issues a warning if the duty point of the pumps moves out of the defined range. The warning is given with a set time delay. It is possible to choose whether the warning is to be reset automatically or manually when the duty point comes within
6 Advanced control in packaged systems The ability to monitor or even control the pump system remotely is an important feature in many applications. The MPC s digital input and output capability can be expanded to meet many requirements. The available SCADA bus protocols for integrating the controls into a building management system include the following options: Profibus Modbus LON BACnet GSM USER-FRIENDLY INTERFACE Large, backlit graphic display screen with overview of the system, including key measuring points Menu bar for easy navigation System information and status Control functions Cascade control Alternation Speed control Help function for each screen the pump system interface to your PC screen, either by connecting it directly or by defining an IP address for the Hydro MPC and logging on via the internet. REDUNDANT SENSORS In order to increase reliability, a backup primary sensor can be connected as a redundant sensor. With the redundant sensor installed, the CU352 monitors both sensors, and in case of dissimilarity between the outputs of the sensors, the CU352 displays a warning. If a fault is registered on a sensor (i.e. the sensor output is out of range) the CU352 automatically switches to the other sensor. INSTALLATION WIZARD GETS YOU STARTED Grundfos created an installation wizard to make it simple and straightforward to operate the Hydro MPC. The installation wizard guides the operator through a sequence of instructions to ensure that all settings are made in the correct order and that system performance, as well as required protection settings (e.g. water-shortage protection), are set up step by step. Correct installation and commissioning of any pump system is a prerequisite for attaining optimum performance of the system and trouble-free operation. ETHERNET CONNECTION As standard, the MPC comes with Ethernet connection possibility. The Ethernet solution lets you easily import
7 Expect reliability, maintainability and adaptability Grundfos pump systems represent reliability, efficiency, and adaptability. Our pump systems are the obvious choice for any application: they re built to last and feature a wide range of user benefits. TESTED FOR DEPENDABILITY At Grundfos, there are no compromises when it comes to quality. We use only the best materials and state-of the-art technologies, so you can have confidence in the finished product. Each pump as well as the final system configuration have been carefully inspected and tested before leaving the factory. FULLY ADAPTABLE TO YOUR APPLICATION Grundfos Hydro MPC systems adapt to variations in demand at all levels and at any time. Whether in commercial buildings or in industrial applications, a Grundfos pump system is capable of maintaining pre-set control parameter. This capability prevents undesirable fluctuations and keeps energy consumption at the lowest level possible while reducing wear and tear on pipes and valves. SERVICE ABILITY The Grundfos CR multistage pump is by far one of the most service friendly pumps on the market. The highquality cartridge mechanical seal minimizes downtime for repairs and if the seal needs replacing it can be done in matter of minutes. Grundfos CR pumps are equipped with a unique, easy-toreplace cartridge shaft seal that s available in a choice of materials. It can handle temperatures from -40 F to 250 F. Hydro MPC Complete integrated pumping systems Data Flow, Q (4 pumps): Max gpm Flow, Q (6 pumps): Max gpm Head, H: Max. 500 ft Liquid temp.: Max. 250 F Working press.: Max. 232 psi Main applications Water supply Irrigation Municipal HVAC Industrial plants
8 COMMITTED TO EXCELLENCE IN PUMPING Grundfos is one of the world s leading manufacturers of pumps and pumping systems and was the first company ever to develop a multistage in-line centrifugal pump. The current CR pump series remains second to none in terms of efficiency, reliability, and long-term operation costs. These superior product features characterize the Grundfos range of Hydro MPC systems and contribute to making Grundfos pump systems the unrivaled market leaders, whether for commercial building projects or industrial applications. Grundfos Hydro MPC systems are fully integrated systems made to the very highest standards. The advanced MPC controller features a user-friendly interface, making these pump systems capable of handling the most difficult jobs with ease and accuracy. L-BPQ-SL (US) GRUNDFOS Kansas City West 118th Terrace Olathe, Kansas Phone: (913) Fax: (913) GRUNDFOS Canada 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: (905) Fax: (905) The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS Mexico Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto C.P Apodaca, N.L. Mexico Phone: Fax:
GRUNDFOS PRESSURE BOOSTING. Dynamic Pressure Boosting Solutions from Grundfos
GRUNDFOS PRESSURE BOOSTING Dynamic Pressure Boosting Solutions from Grundfos 2 GRUNDFOS PRESSURE BOOSTING Superior Boosting and State-of-the- Art Reliability and Efficiency INTRODUCTION 3 THE OPTIMAL CHOICE
Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function
Belimo Energy Valve TM web server manual P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Contents General
Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations
Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations 2 One Solution for Monitoring, Control or Both There are many ways to improve the efficiency and reliability of your
No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps
grundfos se & sl ranges Submersible and dry-installed wastewater pumps 0.9-30 kw 2, 4, 6 pole 50Hz No compromise Highest total efficiency wastewater pumping ULTIMATE WASTEWATER PUMPING TECHNOLOGY The renewed
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
High-precision valve control using intelligent positioners. sipart
High-precision valve control using intelligent positioners sipart The SIPART PS2 electropneumatic positioner is number 1 in its field by a very wide margin. Our past experience gathered from 10 years in
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Water cooled chiller plant (cp/vs)
Data Center Water cooled chiller plant (cp/vs) Design Envelope File No: 9.573 Date: december 16, 2014 Supersedes: 9.573 Date: november 14, 2014 design envelope s performance improvements are among the
SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.
Contact Wheel / Encoder Counter Length & Speed Errors through slippage and wear, result in Short Lengths and Give Away. Maintenance Costs, through calibration downtime and replacement parts. Marking and
Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring function
Belimo Energy Valve TM web server manual EV..R+BAC P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Efficient and reliable fans, compressors and blowers
Efficient and reliable fans, compressors and blowers Reliable operation p rotects your process Reliable operation Energy savings Low operating cost Extended equipment lifetime Would you like to protect
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
SmartVFD HVAC and BYPASS
SmartVFD HVAC and BYPASS The Smart Choice for Energy Savings. Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced in North America and roughly half of that is
Intelligent Vibration Monitoring
Diagnostic Systems Condition Based Monitoring Diagnostic Systems Condition Based Monitoring Intelligent Vibration Monitoring efector Octavis for real-time vibration monitoring Solutions for Predictive
NXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
R&S BC NETSTATE Open network management software for broadcast applications
R&S BC NETSTATE Open network management software for broadcast applications Broadcasting Product Brochure 01.00 R&S BC-NETSTATE At a glance R&S BC NETSTATE is a specialized software solution for broadcast
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
GE Intelligent Platforms. PACSystems High Availability Solutions
GE Intelligent Platforms PACSystems Solutions Minimizing the high cost of downtime To keep your essential systems running, PACSystems ensures continuous, efficient operations with superior performance
How To Install A Mazzei Injector
TECHNICAL BULLETIN No. 4 USE OF MAZZEI INJECTORS IN WATER-WELL / PRESSURE TANK APPLICATIONS The selection, installation and use of Mazzei Injectors in water-well/pressure tank systems is quite straightforward.
GETINGE CLEAN MANAGEMENT SYSTEM
GETINGE CLEAN MANAGEMENT SYSTEM 2 Getinge Clean Management System GETINGE CLEAN MANAGEMENT SYSTEM (CMS) AN IMPROVED PROCESS, A UNIQUE SOLUTION Getinge can help you manage your detergents and reduce costs.
Low Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient
Rosemount TankMaster So advanced that it s easy to use
Rosemount TankMaster So advanced that it s easy to use The Emerson logo is a trademark and servicemark of Emerson Electric Co. Rosemount TankMaster is a trademark of Rosemount Tank Radar AB. IFIX is a
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
Medical Vacuum Systems-PXMI
Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
Wireless solutions for water and wastewater management
Water and wastewater management Wireless solutions for water and wastewater management Visit the website to learn more about Eaton wireless and wired solutions Flexible, cost-effective, integrated solutions
DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE
FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP1100J FTA1100J Diesel Engine Fire Pump Controllers Product Description Description Firetrol combined automatic and manual Mark
Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009
Applying Pressure Independent Control Valves in H.V.A.C. Systems A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009 1 Introduction I know, as building design consultants, so much of your effort
A Real Time, Object Oriented Fieldbus Management System
A Real Time, Object Oriented Fieldbus Management System Mr. Ole Cramer Nielsen Managing Director PROCES-DATA Supervisor International P-NET User Organisation Navervej 8 8600 Silkeborg Denmark [email protected]
savic-net for Integrated Building Management System
Specifications savic-net for Integrated Building Management General The savic-net for Integrated Building Management (hereinafter referred to as savic-net for IBMS) integrates variou sub systems by open
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary
Installation Service Statement of Work - 1 - Cooling Start-up Service Cooling Start-up Service Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details
FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
HMS Industrial Networks
HMS Industrial Networks Putting industrial applications on the cloud Whitepaper Best practices for managing and controlling industrial equipment remotely. HMS Industrial Networks AB Stationsgatan 37 30245
Contents. Introduction
TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER
NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while
Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and ontrollers for Gases Reliable and accurate: Thermal Mass Flow Meters and ontrollers Reliable technology and standardized interfaces make
Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier
Help Help Software Tutorial Building a load sizing project with an ME Series Humidifier 502-B 18 Aug 2015 Help Tutorials provide step-by-step examples of complete load sizing projects and browser projects
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Panorama. Softstarters The complete range
Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated
Designer. of control solutions NA O7.124A
u n i v e r s a l c o m f o r t Designer of control solutions NA O7.124A CONTROL ADAPTED TO THE ENTIRE RANGE V for Vision: Our range of CIAT controls features all the techniques used for air conditioning,
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:
Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission
The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems
The Best Technology for the Application Educating the Specifier on Medical Air & Medical Vacuum Systems Want to discuss the technologies Feel an educated specifier is the best business partner Often hear
Y-200 Multi-Stage Sequencer
Y-200 Multi-Stage Sequencer Designed for use with single or multiple space heating or hot water supply systems, the Y-200 is offered in 4- and 8-stage configurations and is available loose or factory-mounted
AutoLog ControlMan. Remote Monitoring & Controlling Service
AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via
Partner for automation Water technology
Partner for automation Water technology Your objective: Economy in plant engineering and plant lifecycle management Energy prices today are high and rising even further, forcing you as municipal or industrial
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management
My2B GSM/GPRS Datalogger with Alarm Management 100% Made & Designed in Italy My2B GSM/GPRS Datalogger with Alarm Management MY2B ( Standard / Datalogger) is a GSM / GPRS telecontrol unit for home & building
NMC Pro System Manager
NMC Pro System Manager Maximize the Performance of Your Irrigation System from One Central Location DRIP/MICRO IRRIGATION PRODUCTS Monitor and Control from One Central Location The NMC Pro System Manager
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
Building Control Solutions
Building Control Systems Building Control Solutions JaCreated by Honeywell March 14, 2014 customer.honeywell.com TO: FROM: Authorized System Distributors Authorized Controls Integrators Building Control
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
It s all open from here.
It s all open from here. Never let technology impose limits on your future. That thinking drove the design of Honeywell EXCEL 5000 OPEN systems the most flexible and open communication platform for building
Chilled Water System Commissioning: Variable Primary Flow. John D. Villani, P.E. Associate Grumman/Butkus Associates
Chilled Water System Commissioning: Variable Primary Flow John D. Villani, P.E. Associate Grumman/Butkus Associates AIA Quality Assurance Learning Objectives 1. History of chilled water system configurations
FAAST. Fire Alarm Aspiration Sensing Technology
FAAST Fire Alarm Aspiration Sensing Technology The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m2 state-ofthe-art facility
DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.
DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES Presented By: Rick Rumsey, P.E. Data Collection Customer Information Pump Motor Information Pump Information Irrigation System Information Historic
Battery Powered Digital Mass Flow Meters for Gases
Next Generation red-y compact: AA Battery Powered Touch Technology Micro-UB Port red-y compact series product information Battery Powered Digital Mass Flow Meters for Gases Independent digital convenience:
Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface
IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
ROTALIGN Ultra is The intelligent System for Machinery Alignment
ROTALIGN Ultra is The intelligent System for Machinery Alignment 2 sensalign improves the quality of your alignment XXL HD PSD (Ultra-large High Definition Position Sensitive Detector) At a glance Real
Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats
Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,
scalable data centre energy management solution
scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology
Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s
Liebert Liebert Liqui-tect Leak Detection and Reporting M o n i t o r i n g S o l u t i o n s COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPES Accurate, Reliable Systems For Detecting, Locating
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
SHORT TRAINING COURSES
Post Office Box SR 95, Spintex Road, Ghana Tel: +233 302 812680, Fax: +233 302 814709 E mail: [email protected] Website: www.automationghana.com SHORT TRAINING COURSES Equipping industries with
Excellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions
SCADA Systems March 2012 / White paper by Schneider Electric Telemetry & Remote SCADA Solutions Make the most of your energy Summary Executive Summary... p 2 Introduction... p 3 Field Instrumentation...
Access control designed simply for you
TruPortal Access control designed simply for you QUICK START GUIDE Introduction TruPortal access control solutions have been engineered and designed to install quickly and easily right out of the box.
HMS Industrial Networks. Putting industrial applications on the cloud
HMS Industrial Networks Putting industrial applications on the cloud Whitepaper Best practices for managing and controlling industrial equipment remotely. HMS Industrial Networks Inc 35 E Wacker Drive,
IP Sensing Water & Wastewater AMR/SCADA System
IP Sensing is Pleased To Be Presenting The: IP Sensing Water & Wastewater AMR/SCADA System 12/09/11 Key Markets Addressed by IP Sensing Products Are: Remote Monitoring AMR/SCADA for Water and Wastewater
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller
Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the
POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)
IM213P-MC 0312 0003 POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE) INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
EDS / EDS-3G EFFICIENCY DATA SERVER
EDS / EDS-3G EFFICIENCY DATA SERVER TUTORIAL M98231301-03-12B CIRCUTOR SA TABLE OF CONTENTS 1. INTRODUCTION:... 4 1.1. PRINCIPAL FEATURES OF THE EDS/EDS-3G:... 5 1.2. TYPE OF EDS/EDS-3G APPLICATIONS:...
http://www.t-balancer.com/english/produkt_tban_sw.htm
Seite 1 von 15 Configuration assistant An assistant guides you step by step through the customization process: Tacho function Speed signal ca be monitored for each fan channel. Seite 2 von 15 Manual Mode
Safety Requirements Specification Guideline
Safety Requirements Specification Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary Safety Requirement