350500 Dynamic Pressure Charge Amplifier



Similar documents
3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

3500/40M Proximitor* Monitor

Low Frequency Velocity Sensor

3500/25 Enhanced Keyphasor*Module

and Accelerometers

1701/22 FieldMonitor Management Interface Module

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Velomitor Piezo-velocity Sensor

3500/22M Transient Data Interface

3500/93 System Display

3500/62 Process Variable Monitor

Proximity Transmitters and Seismic Vibration Transmitters

Differential Charge Amplifier

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Inductive sensor NI10-M18-Y1X-H1141

9000 Series Accelerometers Specifications

TAC I/NETTM MR-AHU-HP. Application Specific Controller

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

3DLevelScanner II TECHNICAL DATA SHEET

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

S-series Mass Connection Solutions

C ole s quality Open Frame Instrument Rotary Switch provides low

Technical Data Sheet. 3DLevelScanner

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Application Note TMA Series

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Electronic Control Devices The European Product Catalogue 2007

MACTek Corporation. USB HART Interface. Users Manual

2002 IS Catalog. Page

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Contents. Document information

DeltaV SISnet Repeater

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

TX2123 RS485 TO ETHERNET ADAPTOR

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Micro Motion 3098 Gas Specific Gravity Meter

M-Bus Network Installation Notes

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Combustion Dynamics Instrumentation

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Technical Data. Dimensions

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

How To Power A Schen

Kit Watt Audio Amplifier

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

T7560A,B,C Digital Wall Module

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

ROC800-Series Advanced Pulse Module

Analog signal converters CC-E I/I Current / current isolators

Experiment 5. Strain Gage Measurements

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

FGM 160 ATEX EC type examination certificate

Triple Waveband Infra-Red Flame Detection

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Foxboro Evo Process Automation System

Power Supplies 3. SDN-P DIN Rail Series

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

DS 600. A contact free flux gate based current measurement sensor 600A rms

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Electronic Control Devices The European Product Catalogue 2007

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Energy Management Energy Meter Type EM23 DIN

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

FCS-MBx-SG Megablock series*

Research RF Sputtering Packages

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Cables KEITHLEY (U.S. only) ACCESSORIES

AXIS T81B22 DC 30W Midspan

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Redundancy Module QUINT-DIODE/40

CompactLogix Power Supplies Specifications

PRODUCT SPECIFICATION

Transcription:

350500 Dynamic Pressure Charge Amplifier Bently Nevada* Asset Condition Moniting Description The 350500 Dynamic Pressure Charge Amplifier (DPCA) is a component in a dynamic pressure sensing system. This sensing system, which monits pressure pulsations that result from combustion instability in gas turbine engines, consists of a charge-coupled piezoelectric pressure sens, low noise interconnect cable, 350500 charge amplifier, and moniting device. The dynamic pressure sens should be a high temperature piezoelectric type that converts dynamic pressure to an output signal scaled in pico-coulombs per unit of pressure. The 350500 charge amplifier design allows its use with a number of senss designed to monit combustion instability. The interconnect cable, which connects the sens with the charge amplifier, is a specially designed low-noise, environmentally robust cable. The 350500 DPCA offers two interconnect cable options. The 350500 charge amplifier converts the sens charge signal to a low impedance voltage output signal. This signal is suitable f Bently Nevada monits such as the 3500/64 Dynamic Pressure Monit. The electrical interface from the monit to the charge amplifier, which consists of 24 Vdc power, common, and signal, is the same as that f a Bently Nevada Proximit*. Appropriate safety barriers can be used between the charge amplifier and the moniting device. Page 1 of 7

Specifications All Specifications are at 23 C ± 2 C, (73.4 F ± 3.6 F) Installation Install per Installation Drawing 145131 in a safe area CSA\NRTL\C Class I Division 2, Group A, B, C, D hazardous area Class 1 Zone 2 IIC. Install per Drawing 146821 f Intrinsically Safe Division 1 Class 1 Zone 0 IIC applications. 350500 Electrical Specifications Power: Supply Voltage (at the module) Supply Current Signal: Input Sensitivity Expected Sens Pole-to-Pole Capacitance f different Input Sensitivities - 19.60 Vdc to 26 Vdc when no safety barriers are used -17.75 Vdc to 26 Vdc when safety barriers are used. 14.68 ma maximum with no load11.69 ma typical with no load Ordered option: 13.8 pc/psi (200 pc/bar) 16 pc/psi (232 pc/bar) 1200 pc/psi (17,404 pc/bar) 12 pc/psi (174 pc/bar) 60 pc/psi (870 pc/bar) Input Sensitivity Option in pc/psi: 13.8 16 1200 12 60 Nominal Pole- Pole Capacitance in picofarads: 320 60 to 90 6,300 100 300 Output Sensitivity Dynamic Range Common Mode Rejection Output Resistance Frequency Response Physical Dimensions: Weight: Mounting: Power/Signal Connect and Wiring: Ordered option: 100 millivolt/psi ( 1.45 Volt/bar)± 2% @ 150 Hz ±50 psi pk -40 db better in the passband. 50 ohm typical Ordered option: High (See Figure 1) See figures 3 and 4 246 grams (8.7 oz) Low Panel mount and 35 mm DIN rail mount options. (See Figures 3 and 4) Three-conduct SpringLoc terminal strip f power, instrument common, and signal output. Accepts wire sizes of: 0.2 mm 2 to 1.5 mm 2 (16 to 24 AWG) without ferrules, and 0.25 mm 2 to 0.75 mm 2 (18 to 23 AWG) with ferrules. Recommended field wiring is a three-conduct shielded triad. Maximum length of 305 metre (1000 feet) between the charge amplifier and the monit. Page 2 of 7

Sens Connect: Two-pin LEMO EXG.0B.302.HLN (mates to LEMO FGG.0B.302 equivalent) Environmental Limits Operating Stage Operating and Stage Humidity: Hazardous Area Approvals Nth America: Europe: International: Three-pin MIL Connect (mates to MS3116F8-3S equivalent) -20 C to +70 C (-4 F to +158 F) -40 C to + 85 C (-40 F to +185 F) 0% to 95% relative noncondensing Class I Division 2, Groups A, B, C, D Class I Division 1, Groups A, B, C, D CSA Class I Zone 0 Ex ia IIC T4 Class I Zone 2 Ex na IIC T5 Ex ia IIC T5 Ga Ex na IIC T5 Gc Ex ia IIC T5 Ga Ex na IIC Gc Compliance and Certifications EMC: European Community Directives: Standards: EMC Directive 2004/108/EC EN 61000-6-2:2005 EN 61000-6-4:2007 145536 Interconnect Cable Specifications Unless noted otherwise all Specifications are at 23 ±2 C, (73.4 F ±3.6 F) The 145536 Interconnect Cable is a double shielded, double jacketed, low noise treated, twisted pair cable designed specifically f use with the 350500 DPCA. Sens Connect: Charge Amp Connect: Cable Operating Conduct to conduct capacitance: MS3106F-10SL-4S (Mil spec two pin connect) (Mil spec three pin connect) LEMO FGG.0B.302.CLAD.56 Three-pin MIL Connect 150 Celsius maximum (302 F) 30 pf/ft nominal 145693 Interconnect Cable Specifications Unless noted otherwise all Specifications are at 23 ±2 C, (73.4 F ±3.6 F) The 145693 Interconnect Cable is a double shielded, double jacketed, low noise treated, twisted pair cable designed specifically f use with the 350500 DPCA. It can be dered in lengths from 1 to 15 metres in 1- metre increments. Page 3 of 7

Sens Connect: Charge Amp Connect: Cable Operating Conduct to conduct capacitance: M83723/95G10207 (Mil spec two pin connect) MS3116F8-3S (Mil spec three pin connect) LEMO FGG.0B.302.CLAD.56 Housing Specifications Three-pin MIL Connect 200 C maximum (392 F) 70 pf/ft nominal 330181 Housing. See Data Sheet 141195-01 f Specifications and Ordering Infmation. This housing is used with 3300 XL Proximit and can also be used f the 350500. Up to six (6) DPCA s can be mounted in panel mount configuration and up to eight (8) in DIN mount configuration. Ordering Infmation 0 2 13.8 pc/psi (200 pc/bar) 0 3 12 pc/psi (174 pc/bar) 0 4 60 pc/psi (870 pc/bar) B: Low Pass Frequency Option 0 0 High 0 1 Low (See Figure 1) C: Output Sensitivity Option 0 0 100 mv/psi (1.45 V/bar) D: Mounting Option 0 0 Panel Mount, LEMO Connect 0 1 35 mm DIN Mount, LEMO Connect 0 2 No Mounting Hardware, LEMO connect *1 0 Panel Mount, MIL Connect *1 1 Din Mount, MIL Connect *1 2 No Mounting Hardware, MIL Connect *Ordering options 10, 11 12 f D limits the input sensitivity option (dering option A) to be either 00 (16 pc/psi (232 pc/bar)) 04 (60 pc/psi (870 pc/bar)). E: Approvals 0 0 No Approvals 0 1 CSA/NRT/L Class 1 Div 2, Groups A,B,C,D 0 5 Multi Agency Approvals Interconnect Cables 145536 01 145536 02 145693 AA This cable is 15.24 metres long (50 feet) and has a MS3106F-10SL-4S sens connect. Identical to -01 with overmold on the sens side connect. This cable has a M83723/95G10207 sens side connect and can be dered in lengths from 1 metre to 15 metre in 1-metre increments Dynamic Pressure Charge Amplifier 350500-AA-BB-CC-DD-EE-FF A: Input Sensitivity Option 0 0 16 pc/psi (232 pc/bar) 0 1 1200 pc/psi (17,404 pc/bar) A: Length option 01 to 15 metres in 1-metre increments Page 4 of 7

Frequency Response Plots Typical Low Frequency Cner vs. External Capacitance (Low Pass filter option set to High ) 11.00 Cner Frequency (khz) 10.90 10.80 10.70 10.60 10.50 10.40 10.30 10.20 10.10 60 pc/psi 16 pc/psi 12 pc/psi 1200 pc/psi 13.8 pc/psi 10.00 9.90 9.80 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5 10.5 11.5 12.5 External Capacitance (nf) Figure 1: Low-Pass Filter option set to High. External Capacitance is the pole-to-pole cable capacitance plus the capacitance of the sens Typical Low Frequency Cner vs. External Capacitance (Low Pass filter option set to Low ) 4.36 4.35 1200 pc/psi Cner Frequency (khz) 4.34 4.33 4.32 4.31 4.30 60 pc/psi 16 pc/psi 12 pc/psi 13.8 pc/psi 4.29 4.28 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5 10.5 11.5 12.5 External Capacitance (nf) Figure 2: Low-Pass Filter option set to Low. External Capacitance is the pole-to-pole cable capacitance plus the capacitance of the sens Page 5 of 7

Dimensional Drawings (Dimensions in inches) Figure 3: 350500 Panel Mount Option Page 6 of 7

Figure 4: 350500 DIN Mount Option * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. 2000 2013 Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-mcs.com/bently Page 7 of 7