LS Automotive Wire & Cable Environment-friendly cable for the safety of your car



Similar documents
Automotive Wire and Cable Products

Company Profile Gaon Cable Co., Ltd.

From a single wire harness to an entire Electrical Distribution System (EDS), PKC delivers power where and when you need it.

Contact Hueson Corporation for additional information or details Sutton Street Northbridge, MA

New micro size drive of LS Industrial Systems STARVERT

The Quality Connection. Single-core automotive cables

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

100% EMI Emission Containment

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Section kv Power Cables

Building Cables and Wires

Industrial Cable Solutions for Variable Frequency Drives

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

HARTING Ethernet Cabling 4-poles Overview

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

INTERNATIONAL STANDARD

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

GHCABLE Danyang Ganghong Electric Wire & Power Cable Co.,Ltd

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Commercial Coaxial Cable

Communication, Signal & Data Cables

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Marine & Shipboard Cable JIS C 3410(1999) IEC , 353, 354, 376

CAVEL VS80205 MADE IN ITALY 1000 V

RF cables. Edition 2015

Coaxial Cables for Medium-Frequency Applications

Gulf Cable & Electrical Ind. Co.

UGVCL/SP/591/11KV HT AB CABLE

International Electrotechnical Commission Standards

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

SPECIALTY CABLES APPLICATIONS SUPPORTED

Speciality Cabling Solutions

INCORPORATING WEIGHT-SAVING TECHNOLOGY IN AEROSPACE APPLICATIONS: AT WHAT RISK?

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

RF & Microwave cable assemblies C291

CONFLEX ELECTRIC CABLE

COAX Cables Radio Frequency Cables

Festoon 715 P PUR cable for flexible application in festoon systems

VIPERFLEX ELECTRIC CABLE

Wire, Cable, and Battery Accessories Product Catalog

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Cables. Accessories. For Force, Torque and Strain Sensors

Accelerating Light. Copper Cabling Solutions. Category 6A

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Raychem Custom Multicore (Multiconductor) Cables

GIS. Gas Insulated Switchgear

Hitachi Cable, Ltd. Auto Parts Business Strategy

CABLE BASICS. Sizing and Selection Standard vs. Custom. Presented by

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Power supply unit Model: PAC-SC50KUA

The Quality Connection. LEONI Dacar Automotive cables

Directory chapter 04

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

Instrumentation Cable Power Cable Assembly Solutions...32

ETHERLINE Ethernet Cable, Connectors & Tools

Specification SFTP CAT6 Network Cable 23AWG CU

Low Pressure Molding Solutions

The original heating cable just got better

Network Standard Advice No. 1420C 9/6/2011

with coloured cores and overall copper screen UL/CSA... 17

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Global cable expertise for rolling stock

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

Hook-Up and Lead Wire

Low Voltage Wires and Cables: New Applications for Thermoplastics. Chapter 1 of 3: A Global Mini Database of Constructions

Operating Instructions

Times Microwave Systems Hermetically Sealed Assemblies

RADOX railway cables acc. to EN and EN Edition 2009

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Gulf Cable & Electrical Ind. Co.

Understanding Shielded Cable

Flexible Control Cables

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

FIRE RESISTANT CABLES FP200 GOLD

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Fire Resistant Cables

Servo Motor & Drive Cables

Cables and Accessories Selection Guide

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

6000 Series Buccaneer

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

W-2. Stranding Comparison

DIRECTCONNECT SERVICE

Lean Manufacturing Solution

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Instrumentation Cable Experts

Teledyne Cable Solutions

XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD

Transcription:

Leading Solution LS Automotive Wire & Cable Environmentfriendly cable for the safety of your car www.lscable.com 2005 LS Cable, Ltd. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of LS Cable and its licensors, if any.

New Dream, New Start To become a leader in the competitive global market, LG has been divided into three groups, electronics and chemicals for LG, energy and distribution for GS, Industrial electric electronics and material for LS based on their business specialties. LS' main companies, such as LS cable, LS industrial systems,lsnikko copper, Gaon cable, E1 and Kukdong City gas, are ranked as No.1 in their respective industry. However, LS won't just sit back, satisfied with being the best in Korea. We will pave the way for becoming the world's best in Industrial electric electronics and material industry with the new CI, LS. Your good partner LG Cable is making a fresh start as LS Cable LS Cable is No. 1 cable maker in Korea and its business fields are telecommunication, electric power, components & materials and machinery. Also, LS Cable is creating new businesses particularly in component and materials industry. LS Cable makes its best to accomplish the vision, 'Your No.1 Creative Partner' and be one of the world leaders with high technology and best level of service. Leading Solution LG Cable, LG Industrial Systems and LGNikko Copper, Gaon Cable, E1 and Kukdong City Gas are starting with a new name, Leading Solution, LS. World incorporating nature and human Electric Power Business Machinery Business Awakening and changing prime power Research & Development Components & s Business Macro world by micro technology Main energy artery lightening the world Telecommunication Business Human communication connecting minds

Safetywarning Instruction AVSS Very Thinwall Lowtension Cables For Automobiles The following safetyrelated instructions are to help you use the products safely and precisely, and to prevent property damage, personal injury or loss of life. Warning If you do not follow these instructions exactly, a FIRE or ELECTRIC SHOCK may result causing severe injury or even loss of life. Untrained person should NOT install, maintain or service the products. AVSS SQMM LS Cable 2003 To minimize the possibility of FIRE, ELECTRIC SHOCK, and OTHER HAZARDS: It may be the cause of a fire or damage by a fire. Do NOT exceed the rated voltage and the maximum allowable current. It may be the cause of an electric shock. Do NOT operate connection when the power is on. A : Lowtension cables for automobiles V : Vinyl insulated SS : Very thinwall type It may be the cause of a fire or an electric shock. Do NOT disassemble or convert the products. Wire harness of lowtension electric circuits for automobiles It may be the cause of a fire or damage by a fire. Keep heatresisting temperature of cable, considering the environment of using. Be sure to earth any screened products. Earth any screened products. : Annealed or tinned stranded copper : Leadfree polyvinyl chloride(0 C) Caution If you do not follow these instructions exactly, a FIRE or ELECTRIC SHOCK may result causing property damage and personal injury. Untrained person should NOT install, maintain or service the products. To minimize the possibility of damage to the products or personal injury: Cable is not untied. Pile up drums after placing them upright. It may be the cause of damage to a cable. When you hang a drum on the crane, keep sufficient length to the extent that an angle of the wire can be less than 60 degrees. It may be the cause of disconnection or breakdown of a cable. Keep a cable within the permissible pulling tension and radius of bend to prevent disconnection or breakdown of the cable. It may be the cause of damage to a cable. an Aframe carrier or a crane. Do NOT drop the drum. JASO D 611 f* f 0.75f 0.5 0.5f 1.25 1.25f 2f (No./mm) 7/0.26 1/0. 7/2 1/0.1 1/0.23 1/0.24 37/0.172 1/0.2 37/0.21 37/0.26 Calculated 717 21 630 37 0.74 0.55 0.57 1.2550 1.215 1.644 0. 0. 1.2 1.2 1.2 1. 0.4 1. 1. 1. 2.1 2.1 1.7 1.7 1. 1. 1. 2.7 50.2 4. 32.7 34.6 24.4 21.7 21.7..6.5 Limit ** 11 1 1 26 2,000 2,000 1, 1, 00 00 It may be the cause of damage to a cable. Keep cables out of water while processing the terminal of cables. Note * f : more flexible stranding ** limit : maximum allowable current at ambient temperature 40 C It may be the cause of damage to a cable. Do NOT use cables for other purposes than noted. Before using products, read these instructions. products after verifying indefinite details besides the above descriptions from our company. Keep this safetyrelated instructions in place it can always be seen by users after reading it. 6 7

CAVS Very Thinwall Lowtension Cables AVS Very Thinwall Lowtension Cables for Automobiles CAVS 1.25SQMM LS Cable 2003 AVS 1.25SQMM LS Cable 2003 Compressed conductor C : Compressed conductor A : Lowvoltage cables for automobiles V : Vinyl insulated S : Very thinwall type A : Lowtension cables for automobiles V : Vinyl insulated S : Thinwall type Wire harness of lowtension electric circuits for automobiles : Compressed Annealed copper : Leadfree polyvinyl chloride(0 C) Wire harness of low voltage electric circuits for automobiles : Annealed or tinned stranded copper : Leadfree polyvinyl chloride (0 C) JASO D 611 (No./mm) Calculated 7/SB* 7 0.7 5 50.2 7/SB 62 0. 5 1.7 32.7 0.5 11/SB 0.46 1.1 5 1. 1. 20. 1.25 /SB 1.27 5 2.1.3 Note * SB : smooth body compressed conductor strands ** limit : maximum allowable current at conductor temperature and ambient temperature 40 C Limit ** 1 2,000 1, 00 JASO D 611 f * f 0.75f 0.5 0.5f 1.25 1.25f 2 2f 3 5 (No./mm) 7/0.26 /0.1 7/2 20/0.1 30/0.1 11/2 34/0.1 /2 50/0.1 26/2 7/0.1 41/2 65/2 50/0.45 Calculated 717 054 630 07 0.7630 0.46 0.652 1.27 1.273 1 1 3.27 5.22 7.52 0. 0.72 1.1 1.2 1.2 1. 1. 3.0 3.7 0.7 0. 1. 1. 2.1 2.5 2.5 2. 2. 3.6 4.4 5.5 1. 1. 2.1 2.1 2.3 2.3 3.1 3.1 3. 4.6 5.5 50.2 61.1 32.7 36.7 24.4 20. 2.3.7.1.2 5.5 3.52 2.32 Limit ** 11 15 15 20 20 26 27 37 50 66 00 00 00 200 200 Note * f : more flexible stranding ** limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C

AV Lowtension Cables for Automobiles AVX/AEX Heatresistant Lowtension Cables for Automobiles AV 1.25SQMM LS Cable 2003 AEX(or AVX) 1.25SQMM LS Cable 2003 A : Lowvoltage cables for automobiles V : Vinyl insulated Wire harness of lowtension electric circuits for automobiles : Annealed or tinned stranded copper : Leadfree polyvinyl chloride(0 C) KS C 3311 (JIS C 3406) Calculated (No./mm) Limit ** A : Lowtension cables for automobiles V : Vinyl insulated E : Polyethylene insulated X : Crosslinked Wire harness of lowtension electric circuits for automobiles; especially used for circuits requiring heat resistance and cold resistance : Annealed or tinned stranded copper AVX : Crosslinked lead free polyvinyl chloride(0 C) AEX : Low halogen or halogen free crosslinked polyethylene(0 C)/Environmentfriendly cable JASO D 60 7/2 630 32.7 f * 20/0.1 07 36.7 0.75f 30/0.1 0.7630 1.1 24.4 0.5 11/2 0.46 1.2 20. 0.5f 34/0.1 0.652 1.2 2 1.25 /2 1.27 2.7 2..3 1.25f 50/0.1 1.273 2.7 2..7 2 26/2 1 1. 0.7 3.3 3.6.1 2f 7/0.1 1 1. 0.7 3.3 3.6.2 3 41/2 3.27 0. 4.0 4.3 5.5 5 65/2 5.22 3.0 0. 4. 5.2 3.52 50/0.45 7.52 3.7 1.1 5. 6.3 2.32 Note * f : more flexible stranding ** limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C 15 21 20 2 27 3 51 73 00 00 00 600 600 400 200 150 (No./mm) Calculated Limit ** AVX/AEX 7/0.26 717 0. 1. 1. 50.2 /11 f* /0.1 054 0.7 1.7 1. 61.1 11/ 0 7/.52 630 32.7 / f 20/0.1 07 36.7 / 0.75f 30/0.1 0.7630 1.1 2.1 24.4 1/17 00 0.5 11/2 0.46 1.2 20. 20/1 00 0.5f 34/0.1 0.652 1.2 2 20/1 00 1.25 /2 1.27 2.7 2..3 2/24 1.25f 50/0.1 1.273 2.7 2..7 2/24 2 26/2 1 1. 3.1 3.4.1 37/33 2f 7/0.1 1 1. 3.1 3.4.2 37/33 3 41/2 3.27 0.7 3. 4.1 5.5 51/44 3f 7/17/0.1 3.02 2.5 0.7 3. 4.2 5.5 50/43 200 5 65/2 5.22 3.0 0. 4.6 4. 3.52 6/60 200 5f 7/30/0.1 5.343 3.1 0. 4.7 5.0 3.52 6/60 200 50/0.45 7.52 3.7 0. 5.3 5.6 2.32 /7 200 f 7/45/0.1.0 3.7 0. 5.3 5.6 2.32 /7 200 Note * f : more flexible stranding ** limit : maximum allowable current at conductor temperature 0 C or 0 C and ambient temperature 40 C 11

AVSSX/AESSX Very Thinwall, Heatresistant, Lowtension Cables for Automobiles HAEXF Heatresistant Lowtension Cables for Automobiles AESSX(or AVSSX) 1.25SQMM LS Cable 2003 HAEXF 1.25SQMM LS Cable 2003 A : Lowtension cables for automobiles V : Vinyl insulated E : Polyethylene insulated SS : Very thinwall type X : Crosslinked H : Heatresistance A : Lowtension cables for automobiles E : Polyethylene insulated X : Crosslinked Wire harness of lowtension electric circuits for automobiles; especially used for circuits requiring heat resistance and cold resistance Wire harness of lowtension electric circuits for automobiles; especially used for circuits requiring heat resistance and cold resistance : Annealed or tinned stranded copper : AVSSX : Crosslinked lead free polyvinyl chloride(0 C) AESSX : Low halogen or halogen free crosslinked polyethylene(0 C)/Environmentfriendly cable : Tinned stranded copper : Crosslinked polyethylene(150 C) JASO D 60(Reference) JASO D 60(Reference) (No./mm) Calculated 7/0.26 717 0. 50.2 11/ 2,000 f * 1/0. 21 0. 4. /11 2,000 7/2 630 1.7 32.7 15/ 1, f 1/0.1 37 1.7 34.6 15/ 1, 0.75f 1/0.23 0.74 1.2 1. 1. 23.6 1/ 0.5 1/0.24 0.56 1.2 1. 1. 21.7 1/17 0.5f 37/0.172 0.57 1.2 1. 1. 21.7 1/17 1.25 1/0.2 1.255 2.1. 27/23 00 1.25f 37/0.21 1.215 2.1.6 2/24 00 2f 37/0.26 1.644 1. 0.4 2.7.5 36/32 2.5f 50/0.26 546 2.1 0.4 2. 3.1 7.6 44/40 Limit ** 0.75 0.5 1.25 2 2.5 (No./mm) /0.1 20/0.1 30/0.1 34/0.1 50/0.1 7/0.1 50/0.25 Calculated 054 07 0.7630 0.652 1.273 54 0. 1.2 1.2 1. 2.1 Note * limit : maximum allowable current at conductor temperature 150 C and ambient temperature 40 C 5 1. 2.7 3.1 3.4 1. 2. 3.4 3.7 61.1 36.7 24.4 2.7.1 7. Limit * 21 23 30 3 44 00 Note * f : more flexible stranding ** limit : maximum allowable current at conductor temperature 0 C or 0 C and ambient temperature 40 C(AESSX/AVSSX)

TWP/GPT For Automobiles TXL/GXL/SXL Environmentfriendly Cables for Automobiles TWP(or GPT) 1.25SQMM LS Cable 2003 SXL(or GXL or TXL) 1.25SQMM LS Cable 2003 TWP : Thinwall, Thermoplastic Insulated GPT : General purpose, Thermoplastic Insulated Wire harness of lowtension electric circuits for automobiles : Annealed or tinned stranded copper : Leadfree polyvinyl chloride (0 C) SAE J 1 Minimum (No./mm) GPT : General purpose, ThermoplasticInsulated 20 7/2 0 34.6 11 1 1/0.234 0.76 1.2 2.5 21. 1/0.27 1. 3.4.7 1 00 1/61 1. 3.0 3.2.62 24 1/0.455 2.1 2.3 6 3.6 3. 5.43 34 1/74 4.65 2. 0.7 4.5 4.7 3.52 47 200 1/0.724 7.23 3.6 0.4 5.6 6.0 2.32 66 200 TWP : Thinwall, ThermoplasticInsulated 24 7/0.203 0.205 0.4 3.25 6 2,000 22 7/0.254 24 0.76 0.4 6 1.7 55.0 2,000 20 7/2 0 0.4 1. 1. 34.6 1, 1 1/0.234 0.76 1.2 0.4 21. 1 /0.254 0.76 1.2 0.4 21. 1/0.27 1. 0.4.7 17 00 1/61 1. 0.4 2.5 2.7.62 23 1/0.455 2.1 2.3 0.46 3.1 3.3 5.43 32 1/74 4.65 2. 0 3. 4.0 3.52 44 200 1/0.724 7.23 3.6 5 4.7 4. 2.32 61 200 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Limit * S : Special purpose G : General purpose T : Thinwall XL : Crosslinked polyolefin insulated Wire harness of lowtension electric circuits for automobiles; especially used for circuits requiring heat resistance and cold resistance : Annealed or tinned stranded copper : Low halogen or halogenfree crosslinked polyolefin SAE J 1 (AWG) (No./mm) Minimum Limit * TXL : Thinwall, Crosslinked Polyolefin Insulated 24 7/0.203 0.205 0.4 3.25 7 2,000 22 7/0.254 24 0.76 0.4 6 1.7 55.0 2,000 20 7/2 0 0.4 1. 1. 34.6 15 1, 1 1/0.234 0.76 1.2 0.4 21. 1 1 /0.254 0.76 1.2 0.4 21. 1 1/0.27 1. 0.4.7 23 00 1/61 1. 0.4 2.5 2.7.62 32 1/0.455 2.1 2.3 0.46 3.1 3.3 5.43 42 1/74 4.65 2. 0 3. 4.0 3.52 56 200 1/0.724 7.23 3.6 5 4.7 4. 2.32 7 200 GXL : General Purpose, Crosslinked Polyolefin Insulated 20 7/2 0 2. 34.6 1 1/0.234 0.76 1.2 2.36 2.5 21. 1 1/0.27 1. 2.56 2..7 24 00 1/61 1. 3.2.62 33 1/0.455 2.1 2.3 6 3.62 3. 5.43 44 SXL : Special Purpose, Crosslinked Polyolefin Insulated 20 7/2 0 0.74 2.5 2. 34.6 1 1/0.234 0.76 1.2 0.76 2.72 3.0 21. 1 1/0.27 1. 0.1 3.02 3.4.7 24 00 1/61 1. 0. 3.5 3..62 33 1/0.455 2.1 2.3 0.4 4.1 4.5 5.43 45 Note * limit : maximum allowable current at conductor temperature 150 C and ambient temperature 40 C 15

FLRYA/B PVC Lowtension Cables for Automobiles FLR7Y ETFE Insulated Lowtension Cables for Automobiles FLRY(or A/B) 1.25SQMM LS Cable 2003 FL : Lowtension cables R : Reduced thickness of insulation Y : Polyvinyl chloride insulated A : Concentric stranded conductor B : Bunched stranding Wire harness of lowtension electric circuits for automobiles : Annealed copper : Leadfree polyvinyl chloride(0 C) DIN 72551, ISO 6722 No. of Minimum Wire Individual Limit * Wire FLRYA : Very thinwall type, PVC insulated lowtension cable( type A) 5 7 0.26 0. 0.2 1.2 1.3 52 2,000 1 0.1 0.22 37.1 1, 0.75 1 0.23 1.2 0.24 1.7 1. 24.7 00 1 0.26 1.35 0.24 1. 2.1 1 1 2 1.7 0.24.7 26 00 1 7 0.24.42 30 00 2.5 1 0.41 0.2 2.7 3.0 7.6 36 FLRYB : Very thinwall type, PVC insulated lowtension cable( type B) 5 0.21 0. 0.2 1.2 52 2,000 0.21 0.22 37.1 1, 0.75 24 0.21 1.2 0.24 1.7 1. 24.7 32 0.21 1.35 0.24 1. 2.1 1 30 0.26 1.7 0.24.7 26 00 2.5 50 0.26 0.2 2.7 3.0 7.6 36 4.0 56 1 2.75 2 3.4 3.7 4.7 51 6.0 4 1 3.3 2 4.0 4.3 3.1 6.0 0 0.41 4.5 0.4 5.5 6.0 1.2 0 200 6 0.41 6.3 0.4 7.5.0 1. 5 0 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C FL : Lowtension cables R : Reduced thickness of insulation 7Y : Ethylene tetrafluoroethylene insulated Wire harness of lowtension engine compartment circuits for automobiles : Tinned annealed copper : Ethylene tetrafluoroethylene(150 C) DIN 72551, ISO 6722 Class D No. of Wire Individual Wire 5 0.21 0. 1.2 52 0.21 37.1 17 0.75 24 0.21 1.2 0.25 1.7 1. 24.7 21 32 0.21 1.35 1. 2.1 26 00 30 0.26 1.7.7 34 00 2.5 50 0.26 5 2.7 3.0 7.6 50 4.0 56 1 2.75 0.4 3.4 3.7 4.7 70 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Limit * 17

FLRY PP Insulated Lowtension,Environmentfriendly Cables for Automobiles FLR33X/FL33X XLTPE Insulated Lowtension Cables for Automobiles FL : Lowtension cables R : Reduced thickness of insulation Y : Polypropylene insulated FL : Lowtension cables R : Reduced thickness of insulation 33X : Crosslinked Polyester insulated Wire harness of lowtension circuits for automobiles : Annealed copper : Polypropylene(0 C, 5 C) Wire harness of lowtension battery circuits for automobiles : Annealed copper : Crosslinked polyester(150 C) ISO 6722 Class C(Reference) ISO 6722 Class D(Reference) No. of Wire Individual Wire 5 7 0.26 0. 0.1 1.25 55. 11 2,000 0.26 1.15 0.22 5 1. 33.0 1 1, 1 0.26 0.24 1. 2.1 22 27 0.26 0.24 2.1 2.3. 2 00 37 0.26 1. 0.2 5 2.7.0 35 00 3.0 45 1 2 3.05 3.3 6.06 52 4.0 56 1 2. 2 3.4 3.7 4.5 60 5.0 70 1 3.0 2 3.7 4.0 3.4 70 200 7.0 5 1 3.7 0.4 4.7 5.0 2.72 3 200.0 7 1 4.3 0.4 5.7 6.0 1.1 11 200 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Minimum Limit * No. of Wire Individual Wire Minimum Limit * FLR33XB : Reduced wall XLTPE lowtension cable( type B) 0.21 37.1 17 1, 0.75 24 0.21 1.2 1.7 1. 24.7 22 32 0.21 1.35 1. 2.1 27 30 0.26 1.7.7 35 2.5 50 0.26 5 2.7 3.0 7.6 50 4.0 56 1 2.75 0.4 3.4 3.7 4.7 70 FL33X : XLTPE lowtension battery cable 4 56 1 2.75 0. 4.0 4.4 4.7 76 6 4 1 3.3 0. 4.6 5.0 3.1 200 0 0.41 4.5 5. 6.4 1. 3 2,000 6 0.41 6.3 7.3.0 1. 1, 25 0.41 7. 1.2.0.7 0.743 261 35 276 0.41.0 1.2.2 11.2 27 32 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C 1 1

FLR1X XLTPE Insulated Lowtension Cables for Automobiles ACW Power Train Cables for Automobiles Primary insulation Jacket FL : Lowtension cables R : Reduced thickness of insulation 1X : Crosslinked thermoplastic polyolefin elastomer insulated Wire harness of lowtension engine compartment circuits for automobiles : Annealed copper : Crosslinked thermoplastic polyolefin elastomer(150 C) Wire harness of lowtension engine compartment circuits for automobiles : Bare or tinned annealed copper : Crosslinked polyalkene(150 C) Jacket : Crosslinked PVDF(150 C) MIL 44/, Engineering Specification No. S7GG401AA DIN 72551, ISO 6722 Class D No. of Wire Individual Wire Minimum Minimum 5 0.21 0. 0.2 1.2 52 2,000 0.21 0.22 37.1 1, 0.75 24 0.21 1.2 0.24 1.7 1. 24.7 22 32 0.21 1.35 0.24 1. 2.1 27 00 30 0.26 1.7 0.24.7 35 00 2.5 50 0.26 0.2 2.7 3.0 7.6 4 4.0 56 1 2.75 2 3.4 3.7 4.7 70 6.0 4 1 3.3 2 4.0 4.3 3.1 2 200 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Limit * No. of Minimum Wire Individual Limit * Wire 5 7 0.26 0. 0.25 1.2 52 2,000 1 0.201 37.1 1 1, 0.75 1 0.24 1.2 5 1.7 1. 24.7 24 1 0.26 1.35 1. 2.1 27 00 30 0.26 1.7 5.7 35 00 2.5 50 0.26 0.4 2.7 3.0 7.6 50 4.0 56 1 2.75 0.45 3.4 3.7 4.7 70 6.0 4 1 3.3 4.0 4.3 3.1 3 200 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C 20 21

SHIELD CABLE For Automobiles Wire harness of low voltage electric circuits for automobiles; especially required for shielding of cable such as sensor leads and electronic circuits : Annealed or tinned stranded copper : Polyvinyl chloride or crosslinked polyethylene Shield : Tinned copper or metal tape(al/mylar tape) Sheath : Polyvinyl chloride Metal Braid Spiral Wrap Metal Tape (Al / PS) Shield Type Description Sheath Shield Core Type AVS AVSS AVX AEX AVSSX AESSX Type Designation AVVSB AVSSVSB AVXSB AEXSB AVSSXSB AESSXSB Core Type AVS AVSS AVX AEX AVSSX AESSX Type Designation AVVSW AVSSVSW AVXSW AEXSW AVSSXSW AESSXSW Sheath Shield Drain wire Shield Sheath Core Type CAVS AVSSX AESSX Type Designation CAVS AMS AVSSXAMS AESSXAMS Shield Type Metal Braid Spiral Wrap Metal Tape Core Type AVS AVSS AVX AEX AVSSX AESSX AVS AVSS AVX AEX AVSSX AESSX CAVS (AVSS) AVSSX AESSX (No. mm 2 ) 1 2 4 1 2 4 1 2 3 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 Core Shield Sheath Wire 4.6 5.4 3. 4.5 4.6 4. 5.4 4.6 5.4 3. 4.5 3. 4.5 4 4.24 5.06 3.44 4.1 4 4.24 5.06 4 4.24 5.06 3.44 4.1 3.44 4.1 2. 3.5 3.3 4.0 3.3 4.0 3.3 4.0 0.7 0.7 0.7 3. 5. 6.6 3.4 5.0 5.7 3. 5. 6.1 6. 3. 5. 6.6 3.4 5.0 5.7 3.4 5.0 5.7 3.44 5.44 6.26 3.04 4.64 5.3 3.04 4.64 5.3 3.04 4.64 5.3 3.04 4.64 5.3 3.04 4.64 5.3 3.1 3.7 4.5 3.7 4.5 5.6 3. 4.4 5.2 3. 4.5 5.2 200 200 200 200 200 200 22 23

BATTERY CABLE For Automobiles BATTERY CABLE For Automobiles(Heatresistant) HBC 15SQMM LS Cable 2003 AEXF 15SQMM LS Cable 2003 Lowtension electric circuits of battery for automobiles : Annealed or tinned stranded copper : Leadfree polyvinyl chloride HBC(0 C), AV(0 C), EB(0 C) Calculated (No./mm) AV : General type battery cable 15f 20f 30f 1//2 1//2 1/1/2.75 1.6 2.03 5.3 6.5 7. 1.1 1.1 7.5.7 1.0.3 11.3 1.37 0.46 47 5 4 174 1, ** ** ** 40f 1/26/2 3.73.1 11. 1 0.473 224 50f 1/32/2 4..1.3.1 4 257 60f 1/3/2 5.5 11.1.3 15.1 15 24 200 HBC : Heatresistant and flexible type battery cable 15 171/2.75 5.3 1.1 7.7.2 1.33 1 1, 20 247/2 1.6 6.3 1.1..2 0. 1,00 30 7 /52/2 2.03 7.. 11.3 25 40 1/26/2 3.73.1 11..6 0.473 224 EB : Thinwall type battery cable 15 1//2.75 5.3 6.5 6. 1.32 1 2,000 20 1//2 1.6 6.5 7.7.1 0.15 0 1, 30 1/1/2 2.02 7..0.4 25 40 1/26/2 3.72.1 1. 0.457 20 50 1/32/2 4..1 11.3 11. 71 241 HEB : Heavyduty battery cable 15 1//2.75 5.3 1.1 7.5.0 1.32 1 1, 20 1//2 1.6 6.5 1.1.7.3 0.15 0 30 1/1/2 2.02 7. 1 11.3 25 40 1/26/2 3.73.1 11. 1 0.473 224 50 1/32/2 4..1.3.1 4 257 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C ** Wooden drum packing Limit * Lowtension electric circuits of battery for automobiles : Annealed or tinned stranded copper AEX/EEX : Low halogen or halogen free crosslinked polyethylene(5 C) AVX/HEBX : Crosslinked leadfree polyvinyl chloride(0 C) Calculated (No./mm) AEX/AVX : XLPE/XLPVC insulated and flexible type battery cable f 7/27/0.26.03 4.5 6.5 6. 1 1, f 7/22/2.3 5.0 7.0 7.4 2 0 1, 15f 1//2.75 5.3 1.1 7.5.0 1.37 151 1, 20f 1//2 1.6 6.5 1.1.7.3 0.46 30f 1/1/2 2.03 7. 1 11.3 47 251 40f 1/26/2 3.72.1 11. 1 0.473 30 50f 1/32/2 4..1.3.1 4 356 200 HEBX : XLPVC insulated battery cable 15 1//2.75 5.3 1.1 7.5.0 1.32 151 1, 20 1//2 1.6 6.5 1.1.7.3 0.15 1,00 30 1/1/2 2.02 7. 1 11.3 25 251 40 1/26/2 3.72.1 11. 1 0.457 30 50 1/32/2 4..1.3.1 71 356 200 EEX : XLPE insulated battery cable for electrical automobiles f 7/27/0.26.03 4.5 6.5 6.7 1. 1 2,000 f 7/22/2.3 5.0 7.0 7.3 2 0 1, 15f 1//2.75 5.3 1.1 7.5 7.7 1.37 151 1, 20f 1//2 1.6 6.5 1.1.7. 0.46 30f 1/1/2 2.03 7. 1. 47 251 60f 1/3/2 5.5 11.1.3. 15 356 200 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Limit * 24 25

BATTERY CABLE For High Voltage Electric Veicles SENSOR LEAD CABLE For Automobiles Shield type Nonshield Cable Shield Cable Al tape Shield Sheath Sheath Al tape Shield Sheath High voltage battery cable harness for elelctric vehicles : Tinned stranded copper or annealed copper : Halogenfree crosslinked polethylene(5 C) Shield : Metal braid or metal leaf and metal braid Sheath : Heatresistant polyvinyl chloride Calculated Shield Structure (No./mm) (No./mm) EEXBS : Shielded type high voltage battery cable for electrical vehicles 03 05 0f 15f 20f 30f 40f 50f 65/0.26 65/2 7/22/0.26 1//2 1//2 1/1/2 1/26/2 1/32/2 3.45 5.23.1.75 1.6 2.03 3.72 4. 3.0 4.2 5.3 6.5 7..1.1 0.7 0. 0. 1.1 1.1 3. 4.6 5. 7.5.7 1 11..3 4.0 4. 6.0 7.7.0 1.3.7 6/ 7/0. 24 7/0. 24 7/0.1 24 /0.1 24 /0.1 24 /0.1 24 /0.1 24 Note * limit : maximum allowable current at conductor temperature 0 C and ambient temperature 40 C Sheath Thick 0. 0. Finished 5.3 6..1 1 1.4 15.7 17.1 A : Lowtension cables for automobiles V : Vinyl insulated SS : Very thinwall type E : Polyethylene Insulated X : Crosslinked U : Polyurethane sheathed SW : Spiral wrap shield Sensor lead cable for antilock brake system for automobiles & Type Designation ABS AVSSV Annealed copper Polyvinyl chloride Polyvinyl chloride ABS AXEU Tinned annealed copper Crosslinked polyolefin Polyurethane ABS AEXEU High stengh copper alloy Crosslinked polyolefin Polyurethane CPS ACPS Tinned annealed copper Modified ETFE Viton CPS AXEUSW Tinned annealed copper Crosslinked polyolefin Tinned copper Polyurethane Type Designation Type Designation Contruction Shield Sheath Shield Wire Sheath (No.x mm 2 ) (No./ mm) AVSSV 2 7/2 * 1.7 7 4.5 AXEU 2 0.75 41/0. ** 1.2 5 1. 1.2 6.2 200 AXEU 2 0.75 42/0.15 ** 1.2 0. 6.2 200 AEXEU 2 7/15/0.0 *** 1.1 0.4 1. 1.2 6.2 200 ACPS 3 1/0.1 ** 0.5 0.17 1.3 4.7 AXEUSW 2 /0.20 ** 6 0.2 6.2 200 Note * Annealed stranded copper wire ** Tinned annealed copper wire *** Highstrength copper alloy conductor 26 27

SENSOR LEAD ASSEMBLY For Automobiles TECHNICAL DATA Interconnection for antilock brake system and crank position sensor for automobiles The current limit values are to be used as a reference when designing and selecting lowtension electric circuit wires for automobiles. In case of multiwiring circuit, the current limit values are decreased as shown in the factor table 1. The below values are also refered to JASO D 60 Type Designation & limit value Type Designation Cable type Conduction Conduction Cable AVSS/CAVS( temperature at 0 C) Ambient temperature 30 C 40 C 50 C 60 C 70 C Ambient temperature and current limit f 7 6 4 ABS ABSVD AVSSV ~5,1 2 mm 2 (Optional) 7 6 4 f 7 5 11 5 0.75f 15 7 0.5 7 AXEU 2 0.75 mm 2 AXEU 2 mm 2 (Male) ~5,1 (Optional) 1.25f 21 1 1.25 21 1 2f 2 26 22 1 ABS ABSUS AVS( temperature at 0 C) Ambient temperature and current limit AXEU 2 0.75 mm 2 AXEU 2 mm 2 (Female) 250~5,1 (Optional) Ambient temperature 30 C 40 C 50 C 60 C 70 C 7 6 4 7 6 4 0.5 7 5 1.25 11 5 2 15 7 CPS AKS AXEUSW 2 mm 2 200~ (Optional) 3 7 5 21 1 2 2

TECHNICAL DATA AV( temperature at 0 C) Ambient temperature and current limit AEX( temperature at 0 C) Ambient temperature and current limit Ambient Temperature 30 C 40 C 50 C 60 C 70 C Ambient Temperature 70 C 0 C 0 C 0 C 1 C 00 000.5 001.25 002 003 005 00 015 020 030 040 050 060 05 0 1 23 31 42 57 75 2 6 17 2 244 26 31 36 21 2 3 51 67 1 2 170 21 240 24 32 11 1 24 33 44 5 7 6 7 5 1 20 246 25 11 20 27 36 47 64 6 0 4 154 170 201 232 6 1 25 33 45 61 5 5 0 2 4 f 0.75f 0.5 1.25f 1.25 2 3 5 21 21 2 3 53 6 11 15 1 1 26 35 47 61 AESSX( temperature at 0 C) 22 30 41 53 7 1 25 33 43 5 5 7 7 17 23 30 Ambient temperature and current limit AVX( temperature at 0 C) Ambient Temperature 50 C 60 C 70 C 0 C 0 C Ambient temperature and current limit Ambient Temperature f 70 C 0 C 0 C 0 C 1 C 7 5 f 0.75f 0.5 1.25f 1.25 2 3 5 15 17 21 22 2 40 54 70 11 11 15 1 1 26 36 4 62 17 23 31 41 54 7 1 25 34 44 5 5 7 7 7 1 24 31 0.75f 1.25f 2f 21 2 1 26 22 1 6 AVSSX( temperature at 0 C) Ambient Temperature f 50 C 60 C 70 C 0 C 0 C 11 7 5 Ambient temperature and current limit Table 1 : limit decreasing factor of multiwiring circuit No. of Core 1 2 3 6 4 6 Distance (corecoe) Arrangement S d S S S S S S 0.75f 1.25f 15 21 1 11 6 S=d S=2xd S=2xd 0.5 0. 0.7 0.7 0.5 0.5 0. 0. 0. 0.5 0. 1 1 0.5 0.5 0.5 0.5 0.5 2f 2 25 21 17 30 31

Automotive Wire & Cable Quality Certificates Products & Systems Electric Power Extra High Voltage Power Cable I Overhead Transmission Line OPGW I Halogen Free Cable I Busduct system I Shipboard Cable I Automotive Wire Telecommunication Optical Fiber I Optical Fiber Cable I Optical Components & Apparatus I LAN Cable I FTTH Leaky Coaxial for Radio Frequency Electronic Components & s Electronic Connector I Lead Frame I Magnet Wire I LCD Components I Copper Wire Rod I Elastomer I Aluminum Product I Copper Foils I Ultracapacitor I Smart Heat Spreader Industrial Machinery Tractor I Air Conditioning System I Injection Molding System I Military Defence Equipment We do what it takes to earn quality certifications like ISO 001, ISO/TS 4 and ISO 001, which sets standards for process control and manufacturing flow. 32 33

Global Network Overseas Branches Overseas Subsidiaries China Office Beijing #05 B17th Fl. Global Trade Center, 36 BeisanhuanDong Rd. Dongcheng Dt. Beijing, China Tel. +65256011~3 Fax. +65256015 Shanghai th Fl. Huamin Empire Plaza, 726 West Yan an Rd. Shanghai 200050 China Tel. +621523733, 7 Fax. +62152376 Japan Office E th Fl. Akasaka Twin Tower 1722, 2Chome Akasaka MinatoKu, Tokyo, Japan Tel. +13352 Fax. +133527363 Jordan Office #1, 1st Fl. 7th Circle Royal Jordanian Terminal Bldg. Amman 11, Jordan, PO Box 160 Tel. +62653113 Fax. +626574 LS Cable [Tianjin] Ltd. : Tianjin, China East of JingJin, Express Yixingbu Toll Gate, Beichen, Tianjin, China Tel. +62226761~(01) Fax. +622267617 LS AirConditioning [Qingdao] Ltd. : Qingdao, China Tonghe Street, Ping Du, Shan Dong Province, China Tel. +65327312047 Fax. +65327312073 LS Cable [Wuxi] Ltd. : Wuxi, China LS Industrial Park, Xin Mei Rd., New Dt. Wuxi 202, China Tel. +655342 Fax. +655345341 LS Machinery [Wuxi] Ltd. : Wuxi, China LS Industrial Park, Xin Mei Rd., New Dt. Wuxi 202, China Tel. +655342 Fax. +655345342 LSVINA So Dau Precint, Hong Bang Dt., Hai Phong, Vietnam Tel. +431540330, 246, 2467 Fax. +431246 Singapore Office 371 Beach Rd. # Keypoint 157 Singapore Tel. +6563422~3 Fax. +6563424 VINALSC 1 Nui Truc Lane, Giang Van St., Ba Dinh, Hanoi, Vietnam Tel. +4472233, 3535 Fax. +447223030 Head Office 21st Fl. ASEM Tower, 15 Samsungdong Gangnamgu, Seoul 57 Korea Tel. +22211 Anyang Plant 555 Hogwedong, Dongangu Anyang, Gyeonggido 43131 Korea Tel. +23241 Gumi Plant Gongdandong, Gumi Gyeongsangbukdo 73070 Korea Tel. +2544671 Indong Plant 643 Jinpyeongdong, Gumi Gyeongsangbukdo 730735 Korea Tel. +254467050 UAE Office #502 Capricorn Tower, Sheikh Zayed Rd. Dubai, UAE, PO Box 17 Tel. +7332445 Fax. +7332446 Russia Office Park Place Moscow 1/1 Leninsky Prospect E711 Moscow 1171 Russia Tel. +745565 Fax. +74556511 LLSMW Lot 1, Mukim, Permatang Tinggi, 000 Bukit Mertajam Penang, Malaysia Tel. +604560(34) Fax. +6045607 LS Cable America, Inc. 20 Sylvan Avenue, Englewood Cliffs, NJ 07632, USA Tel. +12012253 Fax. +120124 Gunpo Plant 200 Dangjeongdong, Gunpo Gyeonggido 4357 Korea Tel. +235031 Jeongeup Plant 3 Jeongeup 3 Industrial Complex Taegokri, Bukmyeon, Jeongeup Jeollabukdo 50 Korea Tel. +26353041 Jeonju Plant 77 Jeonju 3 Industrial Complex Yongnamri, Bongdongeup, Wanjugun Jeollabukdo 56504 Korea Tel. +2632751 R&D Center 555 Hogwedong, Dongangu Anyang, Gyeonggido 43131 Korea Tel. +23501 USA Office 20 Sylvan Avenue, Englewood Cliffs NJ 07632, USA Tel. +12012253 Fax. +120124 34 35