CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor



Similar documents
Centro-Matic Automatic Lubrication Systems System Controls

Temperature & Humidity SMS Alert Controller

User Manual. Humidity-Temperature Chart Recorder. Model RH520

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

API Marine. BMS Presentation. Ballast Measurement Systems

Auto Dialer. Manual E-921APQ E-921GPQ

USB-500/600 Series Low-Cost Data Loggers and Accessories

SECURITY SYSTEM ADP-CAN

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Why a torque measuring system?

DC Electronic Loads 8500 series

SMS GSM Alarm Messenger

User's Guide. Pinless Moisture Meter. Model MO257

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

AC-115 Compact Networked Single Door Controller. Installation and User Manual

4-Channel Thermometer / Datalogger

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

T5000 T000 LCD Digital Fan Coil Thermostat

Temperature & Humidity SMS Alert Controller

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Annex-A TECHNICAL SPECIFICATION

ViewLine At the cutting edge of tomorrow s trends. < 7 m

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Multi-Range Programmable DC Power Supplies 9115 Series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Energy Division

Problem / Solution. The problem:

SENSORED BRUSHLESS MOTOR & SPEED CONTROLLER COMBOS

USB-500 Series Stand-Alone, Low-Cost Data Loggers

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Contents. Document information

Inductive Proximity Sensors

ENAiKOON ultrasonic fuel-level sensor

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Manual. Solar Fountain Mobile Phone Charger

1.44 kw Programmable DC Power Supplies XLN Series

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

PK5500 v1.1 Installation Instructions

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Electronic Control Devices The European Product Catalogue 2007

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

VX 2400 Dimmer User's Manual

High Power Programmable DC Power Supplies PVS Series

S100. GSM House Alarm System.

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

SNMP Web Management. User s Manual For SNMP Web Card/Box

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

PowerLogic Sub Meter Display (SMD and SMDOPN)

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

USB-500 Series Low-Cost Data Loggers and Accessories

RAINCONTROL LCD Special

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

SOUND LEVEL METER 94405

LC/LCD ranges level controllers

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Electronic Control Devices The European Product Catalogue 2007

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

PowerGem Pro Uninterruptible Power Supply

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Configuring Alarms & Relays in the Enhanced Transformer Advantage

STERILIZERS, LABORATORY DRYING OVENS

Multi-Range Programmable DC Power Supplies 9115 Series

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Flexible Counter Series in DIN size 24 x 48 mm

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

R&D Electronics 8440 N. Waukegan Rd., Morton Grove, IL (847) Issue 12/08/06 om_207f.doc --

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Advantium 2 Plus Alarm

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

TMS TANK MANAGEMENT SYSTEM

Owner s Guide SunPower SPRx Solar Monitor Manual Type

AUTODIALLER / QUICKDIALLER - SA132

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Installation & User Manual Radio Remote rev1.0.3

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Model SETR-50 and SETR-51 Trim Tab Control

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Pow-R-Con Multi Function Control

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Back-UPS Pro 1300/1500 Installation and Operation

Transcription:

CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor

Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5 Operation...............................7 Key Functions........................... 7 Turning Alarms ON/OFF.................... 7 Backlight Intensity........................ 7 Display Volts/Amps/Frequency/kW.............. 7 Setting High Volts Alarm.................. 8 Setting Low Volts Alarm................. 8 Setting High Frequency Alarm................ 8 Setting Low Frequency Alarm................ 8 Setting High Kw Alarm................. 9 Calibrating the Voltmeter..................... 9 Auto-Zeroing the Ammeter................ 10 Calibrating the Ammeter..................... 10 Calibrating Frequency..................... 10 NMEA 0183 Sentences.................... 11 Selecting NMEA 0183 or Generator On/OFF........ 11 Notes and Warnings................. 12 Other CruzPro Products................... 16 2003 BV Engineering VAF110AC http://www.cruzpro.com Made in New Zealand Page 2

Introduction The CruzPro VAF110 provides accurate digital metering for AC Volts, Amps, Frequency and Kilowatts. Low/High Voltage, Low/High Frequency and High KW alarms are easily set. When activated, the built-in 85 db alarm will sound and the display will flash the out-of-limit condition. Volts can be displayed from 90 to 300 VACRMS. Amps can be displayed from 0 to 150 amps. Killowatts are displayed from 0.0 to 45.0 kw in tenths. The VAF110 outputs standard NMEA 0183 serial data sentences of AC volts, amps, frequency and kw. If the NMEA 0183 serial data is not required, then this output line can be programmed to turn off a faulty generator. Five levels of backlighting can be selected and the backlights can be remotely turned ON/OFF. All set-up, calibration and alarm values are saved to non-volatile memory. The VAF110 comes complete with voltage and current transformers and is factory calibrated to read within 1%. The large LCD display draws only.035 amps and only.055 amps with full backlighting. The VAF110 is powered with a power source of 9.5 to 33.0 VDC and transient protected. Page 3

Specifications Power supply: 9.50 to 33.00 VDC,.037 amps nominal Operating temperature: 32 to 122 F ( 0 to 50 C) Size: 4.3" x 4.3 x 3.5 deep (110 x 110 x 89 mm). Display Data: AC Volts, AC Amps, Frequency, Kilowatts Resolution: 1 VAC, 1 amp, 0.1 kw Accuracy: Better than 1% for volts and 2% +/-1 digit for amps,.05% for frequency. Volts, amps, frequency all front panel adjustable. Ranges: 90 to 300 VAC 0-150 Amps AC 30-100 Hz 0-45.0 kw Supplied Transducers: Voltage and Current transformers Alarms: High/Low Voltage, High & Low Frequency, High kw Display: 4 digit LCD, 5 levels of backlighting. NMEA 0183: $IIXDR,U,xxx,V,VAF30,*CS for Volts $IIXDR,I,yyy,A,VAF30,*CS for Amps $IIXDR,F,zz.z,H,VAF30,*CS for Frequency $IIXDR,G,aa.a,,VAF30,*CS for Kw Generator Control: NMEA 0183 line programmable as automatic generator shut-down control if generator volts/frequency/kw out of range. Page 4

Installation Before starting the installation, please read this entire section first. Finger tighten the screws that mount the instrument bracket - It is not necessary or recommended to use tools. l Drill a 2-1/8" (55mm) mounting hole where you desire to mount the instrument (Figure 1). l Connect the various wires from Cable 1 and Cable 2 as shown in Figures 2 and Figure 3. l Carefully check all your wiring against figures 2 and 3 and then mount the instrument in the hole. Use only finger tension to tighten the bracket hold-down nuts Figure 1 Page 5

Figure 2 Figure 3 Page 6

Operation Key Functions The t, :, s and Q (V, A, F and Q) keys are used to select what to display, set backlight levels, calibrate volts/amps/ frequency, turn alarms on/off, set alarms and set/change constants. New information is automatically saved to nonvolatile memory. Turning Alarms ON/OFF Press the s key 1/2 second to turn alarms ON. In Voltage mode, the alarm icon will light. Press the t key 1/2 second to turn the alarms OFF. Backlight Intensity Press : the key 1/2 second to adjust the backlight level for night viewing. Each time you press the : key 1/2 second, the level will get brighter 1, 2, 3, 4, OFF, 1, 2,... etc. The blue backlight ON/OFF control wire in cable #2 must be switched to +12/24V for the backlights to work. Display Volts/Amps/Frequency/kW Quick press the V, A, or F key to select Voltage, Amps or Frequency display. To display Killowats, press the V and A keys simultaneously. Page 7

Setting High Volts Alarm While viewing Volts, press and hold the s key for ten (10) seconds until you hear a long beep. The High Volts alarm value will be displayed. Use the t and s keys to set the desired alarm value. Press the : key to save the High Volts alarm value to memory. Setting Low Volts Alarm While viewing Volts, press and hold the t key for ten (10) seconds until you hear a long beep. The Low Volts alarm value will be displayed. Use the t and s keys to set the desired alarm value. Press the : key to save the Low Volts alarm value to memory. Setting High Frequency Alarm While viewing Frequency, press and hold the s key for ten (10) seconds until you hear a long beep. The High Frequency alarm value will be displayed. Use the t and s keys to set the desired alarm value. Press the : key to save the High Frequency alarm value to memory. Page 8

Setting Low Frequency Alarm While viewing Frequency, press and hold the t key for ten (10) seconds until you hear a long beep. The Low Frequency alarm value will be displayed. Use the t and s keys to set the desired alarm value. Press the : key to save the Low Frequency alarm value to memory. Setting High Killowatts Alarm Press the V and A keys simultaneously to view the kw display. While viewing kw, press and hold the s key for ten (10) seconds. You will hear a beep and the High kw alarm value will be displayed. Use the t and s keys to set the desired alarm value. Press the : key to save the High kw alarm value to memory. Calibrating the Voltmeter The VAF110 is calibrated at time of manufacture, but can be calibrated using the front panel keys. To calibrate the voltmeter, press and hold the V and Q keys for 10 seconds (until you hear a long beep) to enter into voltage calibration mode. Use the t and s keys to make the displayed value read correctly. Press the : key to save the calibration data to memory. Page 9

Auto-Zeroing the Ammeter Press the A key to display amps. Then press and hold the A key for 10 seconds (until you hear a long beep) to auto-zero the ammeter. Calibrating the Ammeter To calibrate amps, press and hold the A and Q keys for 10 seconds (until you hear a long beep) to enter into amps calibration mode. Pass a known amount of current through the current transformer (CT) and use the t and s keys to make the displayed value read correctly. Press the : key to save the calibration data to memory. A reasonably high value of current should be used (30 amps minimum) to obtain an accurate calibration. Page 10

Calibrating Frequency To calibrate frequency, press and hold the F and Q keys for 10 seconds (until you hear a long beep) to enter into frequency calibration mode. Using a known frequency, press the t and s keys to make the displayed value read correctly. Press the : key to save the calibration data to memory. NMEA 0183 Sentences The VAF110 outputs serial data of voltage, amps, frequency and kw in NMEA 0183 format. The sentences are output in the following formats: Volts: $IIXDR,U,xxx,V,VAF30,*CS Amps: $IIXDR,I,yyy,A,VAF30,*CS Frequency: $IIXDR,F,zz.z,H,VAF30,*CS kw: $IIXDR,G,aa.a,,VAF30,*CS *CS = Check Sum Selecting NMEA 0183 or External Alarm Output The NMEA 0183 serial data line can be programmed to function as an external generator cut-off switch. In this way the generator can be shut down automatically if the voltage or frequency falls outside the alarm ranges set by the user. Page 11

To toggle the data line between NMEA 0183 and Generator Shut-Off, press and hold down both the t and s keys for 10 seconds (until you hear a long beep). The new output mode is automatically saved to memory. A 5V signal in series with 270 ohms (10 ma Max.) is output to the generator shut-down circuitry whenever an alarm condition exists and the alarms are enabled (armed). Notes and Warnings a) During calibration or setting of alarm values, pressing and holding down the t or s keys will cause the values to scroll faster the longer you hold down the keys. Page 12

Notes Page 13

Notes

Notes

Other CruzPro Products l Depthsounders/w Keel Offset, Deep/Shallow/Anchor Drag Alarms l PC Based DSP Fishfinder for Windows98, NT, SE,XP, 2000 l Speed/Temperature/Logs l Digital DC Volts Gauge/w Alarms l Digital DC Volts Gauge/w Alarms for 3 Battery Banks l Digital Amps Gauge l DC Volts/Amps/Amp-Hour Monitors l AC Volts/Amps/Freq/kW Monitors l LPG/Petrol Gas Detectors/Alarms l Bilge Water Alarms/w Stainless Steel Water Sensor l Intelligent Bilge Pump Controllers/w Stainlesss Steel Water Sensors l Intelligent Windlass Controller/Chain Counters l Digital Fuel Gauges & Fuel Consumption Calculator l Digital Tank Level Gauges for 1 or 3 Tanks /w Separate Alarms l Smart 4 step Alternator Regulator l Marine Security System/w Reliable Intrusion Sensors l RPM/Engine Hours/Elapsed Time Gauges/w Alarm l Digital Engine Temperature Gauge/w Alarms l Digital Oil Pressure Gauge/w Alarms l Digital Temperature Gauges for 1 or 3 Areas /w Alarms l Digital Clock/Watch/Race Timers/w 8 Alarms l 8 and 16 Amp Light Dimmers / Motor Speed Controller l Solar Panel Charge Controllers 6/8/9 & 20 Amps l 4 & 8 Channel NMEA Combiners/RS-232 Convertors l Engine/Exhaust Temp. Monitor & Digital Pyrometer l NMEA 0183 Remote Data Repeater/w 4 Input Channels email: info@cruzpro.com website: www.cruzpro.com