SOUND LEVEL METER 94405
|
|
|
- Randolf Barton
- 10 years ago
- Views:
Transcription
1 SOUND LEVEL METER INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION
2 Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual: Environment conditions 1 Altitude lower than 2000 meters 2 Relatively humidity 90%RH 3 Operation Ambient 0 ~ 40 Maintenance & Clearing 1 Repair or servicing not covered in this manual should be performed by qualified personnel. 2 Periodically wipe the case with a dry cloth. Do not use solvents or eradicator on this instrument. Safety symbols Comply with EMC 2. FUNCTIONS DESCRIPTION This Sound Level Meter is designed for noise project; quality control; illness prevention and cure and all kinds of environmental sounds measurement. It is applied to the sounds 2
3 measurement at factory; school; office; traffic access and household, etc. This unit confirms to the IEC CLASS2 for Sound Level Meters. MAX & MIN measurements Over range display Under range display A & C Weighting FAST & SLOW response Analog AC/DC outputs for connection to frequency analyzer or X-Y shaft recorder 3. SPECIFICATION Standard applied: IEC CLASS2 Accuracy: Frequency range: Dynamic range: dB 31.5HZ ~ 8KHZ 50dB Level ranges: LO:30dB~80dB Med:50dB~100dB Hi:80dB~130dB Auto:30dB~130dB Frequency weighting: A/C
4 Time weighting: FAST ( 125ms ), SLOW ( 1s ) Microphone: 1/2 inch electret condenser microphone Display: 4 digits LCD display with a resolution of 0.1dB Display Update: 2 times/sec. MAX hold: Hold the Maximum reading MIN hold: Hold the Minimum reading HOLD: Hold the readings Alarm function: OVER is when input is more than upper limit of range. UNDER is when input is less than upper limit of range. Analog output : AC/DC outputs from earphone outlet AC=1Vrms,DC=10mV/dB Data output : USB data traffic Auto power off : Meter automatically shuts down after approx. 15 minutes of inactivity. Power supply : One 9V battery, 006P or 4
5 REC FAST A/C NEDA1604 or IEC 6F22. Power life : About 30hours Operation temperature and humidity: 0 ~40,10%RH~90%RH Storage temperature and temperature: -10 ~+60,10%RH~75%RH Dimension : 278 (L) x 76 (W) x 50(H) mm Weight : 350g Accessories : Instruction manual, battery, screwdriver, 3.5mm earphone plug, windscreen, software, USB cable. 4. NAME AND FUNCTIONS
6 CAL 18 DC 9V OUTPUT Windscreen 2 LCD: 6
7 SYMBOL FUNCTION LCD 4 digits MAX Maximum hold MIN Minimum hold OVER over range UNDER under range FAST Fast response SLOW Slow response dba A-Weighting(responseto human sense) dbc C-Weighting(response to machine monitor) Range indicate REC Recording data into computer AUTO Auto level range selection FULL Memory full HOLD Data hold function AutopoweroffPress the SETUP button to disable power off Low battery indicate 7
8 3REC button 3.0 DATALOGGER function Press REC button after it power on, the display will show REC to start Data Recording,press the button again to exit the record (Note: In order to avoid data error, please don t power it off under REC condition, when the REC function is deleted then it can power off). 3.1 Adjusting DATALOGGER response Press the button continuously before power it on,then press,it will be displayed as following: Press LEVEL button to adjust memory time,press HOLD button to hold the setup; 8
9 3.2 Data zero function Press the button continuously before power it on, loosen the button when the display showing CLR after the meter power on, which indicates that the data in DATALOGGER has been deleted. 4SETUP button 4.0.The time chip adjustment Press SETUP button and then power it on,when TIME symbol displays then loosen SETUP, the meter will be under time adjustment mode,at the time the display will show the date as following: 9
10 Press the SETUP button second time, the display showing: The display showing minute adjustment mode, press LEVEL to make the adjustment,press HOLD to keep the setup; Press the SETUP button third time, the display showing: The display showing hour adjustment mode, press ( h-p=p.m, h-a=a.m ) LEVEL to make the adjustment, press HOLD to keep the setup; Press the SETUP button fourth time, the display showing 10
11 The display showing date adjustment mode, press LEVEL to make the adjustment, press HOLD to keep the setup; Press the SETUP button fifth time, the display showing: The display showing month adjustment mode, press LEVEL to make the adjustment,press HOLD to keep the setup; Press the SETUP button sixth time, the display showing: The display showing year adjustment mode, press 11
12 LEVEL to make the adjustment,press HOLD to keep the setup; Press the SETUP button seventh time, the display showing: The display showing initialization of the time chip, press HOLD to keep the setup;time and date have returned to factory setup. When the battery is exhausted or replaced, if the time can t be adjusted then please initialize the time chip first. 4.1.USB communications setting: turn on the meter, connect the meter with the computer correctly, choose the software COM3 ( COM4 ), then press SETUP, disappears from the display to indicate and disable auto power off, that the USB data is transmitting. 5 FAST/SLOW button: 12
13 time weighting selection FAST:Fast sampling measurement, 1 time per 125mS. SLOW:Slow sampling measurement, 1 time per second. 6MAX/MIN button: Maximum and Minimum hold Press this button for one time to enter MAX/MIN measurement, MAX will appear on LCD, maximum sound level will be captured and held until higher sound level is captured. Press the button again, MIN will appear on LCD and minimum sound level will be captured and held until new lower sound level is captured. Press the button one more time to exit MAX/MIN measurement. 7 LEVEL button: Level range selection Each time you press LEVEL button, the level range will change between Lo level, Med level, Hi level and Auto level in the circular. 13
14 8 Backlight button 8.0.Turn the backlight on/off 8.1.DATALOGGER response setting; press the button continuously until INT symbol appears after the meter turn on, press LEVEL to set up the data memory response, then press HOLD to keep the setting. 9 Frequency weighting select button A:A-Weighting C:C-Weighting 10 HOLD button: 14
15 Press HOLD button, The hold function freezes the reading in the display. ⑾Power button Turn the meter power ON/OFF ⑿ External DC 9V power supply terminal For connection with DC 9V power supply. Aperture size: external diameter: 3.5mm, internal diameter: 1.35mm ⒀USB interface USB signal output is a 9600 bps serial interface. ⒁ AC/DC signal output earphone outlet 15
16 DC OUTPUT AC OUTPUT GROUND AC:Output voltage:1vrms corresponding to each range step. Output impedance: 100Ω DC:Output voltage:10mv/db Output impedance:1kω ⒂ Calibration potentiometer(call) For external standard level calibration adjustments. Tripod mounting screw Battery cover Microphone 1/2 inch Electret Condenser microphone 16
17 D C 9V REC FAST A/C Acoustic C alibrator 5. CALIBRATION PROCEDURES 1 Make the following switch settings: Frequency weighting: A-weighting Time weighting: FAST Level range: 50 ~100dB 2Insert the microphone housing carefully into the 1/2 inch insertion hole of the 1kHZ). 3 Turn on the switch of calibrator and adjust the CALL potentiometer of the unit 94.0dB is displayed. NOTE: All products are well calibrated before shipment. Recommended recalibration cycle: 1 year. OU TPUT C AL 6. MEASUREMENT PREPARATION 1 Remove the battery cover on the back 17
18 and put in one 9V battery. 2 Recover the back cover. 3 When battery voltage drops below the operating voltage or battery aging, this symbol will appear on LCD. Replace the 9V battery. 4When the AC adapter is used, insert the plug of the adapter (3.5φ) into the DC 9V connector on the side panel. 7. OPERATING PROCEDURE 1 Power on the meter. 2 Press LEVEL button to select desired level, base on UNDER or OVER do not appear on LCD. 3 Select dba for general noise sound level and dbc for measuring sound level of acoustic material. 4 Select FAST for instant sound and SLOW for average sound level. 5 Select MAX/MIN button for measuring maximum and minimum noise level. 18
19 6 Hold the instrument comfortable in hand or fix on tripod and measure sound level at a distance of 1~1.5 meter. 8. NOTICE i. Do not store or operate the instrument ii. iii. iv. at high temperature and high humidity environment. When not in use for long time, please take out the battery to avoid battery liquid leakage and cautery on the instrument. 9. accessories: 1 installation CD When using the instrument in the presence of wind, it is a must to mount the windscreen to not pick up undesirable signals. Keep microphone dry and avoid severe vibration. 2 USB interface cable 3 screwdriver 19
20 10. Installing the software 1.0 Start windows 1.1 Insert the CD into the CD-drive. 1.2 Run SETUP.EXE installation program in file DISK1, install it to the referred directory 1.3 install CP210X drive software: Connecting the meter with the computer by USB interface, install CP2102 drive software in my computer property:\hardware\facility management\ COM CP210X USB. USB Drive Installation 1. Copy the CP210XWIN Drivers to a certain directory, such as: 20
21 usb_driver. 2. Connect the USB to the computer, the Windows system will show finding a new hardware. Choose specific directory C:\ usb_driver according to the instruction. 3. After Driver installation, a new COM port will be added to the Ports in the Device Manager. Port number will be ranged following the primary COM ports, such as: COM3 or COM Once the drive software is installed, start the application software, connect the meter to the computer by USB, then search for the COMX port occupied by CP210X, press button,the symbol will not appear on the display, which indicate the meter is transmitting data to the computer. 21
22 1.5 Enter the menu REAL TIME\ SETUP to set the monitoring data(data volume, response, monitoring time) 1.6 DATALOGGER menu: The computer read the memory data in the meter when REC not appear on the display and the connection is in order. 22
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
User's Guide. Digital Sound Level Meter. Model 407730
User's Guide Digital Sound Level Meter Model 0770 Introduction Congratulations on your purchase of the Extech 0770 Digital Sound Level Meter. The 0770 measures and displays sound pressure levels in db
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
www.burntec.com User's Guide Integrating Sound Level Datalogger Model 407780
User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
User's Guide. Pinless Moisture Meter. Model MO257
User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other
Distributed by TestEquity LLC 800-950-3457 http://www.testequity.com
Meters Meters Extech sound meters include all the features/functions needed for basic noise level surveys or to meet the requirements for OSHA compliance, community noise ordinances or machine noise evaluation.
SB9011D All-in-one Touch POS Terminal USER MANUAL
SB9011D All-in-one Touch POS Terminal USER MANUAL Table of Contents 1 Overview... 2 1.1 Safety Information... 2 1.2 Electromagnetic compatibility statement... 3 2 Installation Guide... 4 2.1 Appearances...
User Guide. Temperature and Humidity Datalogger. Model 42280
User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
RS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Temperature Datalogger Users Manual
Temperature Datalogger Users Manual Page 1 TABLE OF CONTENTS FEATURES & SPECIFICATIONS... 3 APPLICATIONS... 4 START UP AND GENERAL OPERATION... 5 LCD Display... 5 Turn On Temperature Data Logger... 6 Switch
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN
User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Magic Wand Portable Scanner
Magic Wand Portable Scanner PDS-ST470-VP User Manual Table of Contents 1. Key Features... 3 2. Functional Parts... 3 3. Explanation of the Status Icons... 5 4. Using the Scanner... 5 4.1. Charging up the
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
GPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0
HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
Alpha 10 SERVICE MANUAL. Downloaded from www.cbradio.nl. MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.
Alpha 10 MAX 10 Meter Amateur Transceiver MODEL AM-1000 AM/FM/CW/SSB 6 BAND PROGRAMMABLE SERVICE MANUAL Downloaded from www.cbradio.nl Cover Page LOUDER TALKBACK MOD Alpha 10 Max - Model AM-1000 4.7K Resistor
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560
www.64817.com www.64817.com www.64817.com Integrating Sound Level Meters LA-5570/5560/2560 High-functionality Integrating Sound Level Meters Type1Sound Level Meters High sensitivity Wide band LA-5570/5560
Model SL355 Noise Dosimeter/Datalogger
Model SL355 Noise Dosimeter/Datalogger Software Help Guide Software Introduction The SL355 Noise Dosimeter software allows for setup and retrieval of recorded data in the Noise Dosimeter. A total of 20
SVPRIBOR ALFA DSL. Users Manual
SVPRIBOR ALFA DSL Users Manual TABLE OF CONTENTS THE GENERAL INORMATION... 3 EXPLOITATION CONDITIONS... 3 CHARACTERISTICS... 3 PACKING LIST... 4 SOKCETS PANNEL... 5 CONTROL... 6 TURNING ON THE DEVICE...
HP ProDisplay P17A LED Backlit Monitor. User Guide
HP ProDisplay P17A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Table of Contents. System Requirement of MP3 Player:... 4. Connection and Downloading... 7. Downloading DRM10 Files... 8.
Table of Contents Instructions... 1 Precautions... 2 System requirements... 4 System Requirement of MP3 Player:... 4 Introduction... 5 Features... 5 Charging the Battery... 6 Connection and Downloading...
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
HP ProDisplay P19A LED Backlit Monitor. User Guide
HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying
Pen Drive 2.0 Specification
Pen Drive 2.0 Specification Table of Contents A. General Description..2 B. Controller Outline..3 C. Features.3 D. Capacity Specification.4 E. Power Consumption.5 F. Absolute Maximum Rating...5 G. Installation
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300
User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
RS Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
psi 2.901 0.001 fth20 6.690 0.001 mbar * 200.0 0.01/0.1 cmh20 203.9 0.1 inhg 5.906 0.001 bar 0.200 0.001
Manometer DD890 Introduction The device measures Gauge/Differential Pressure from -200 mbar to 200mbar (+-80.29 in H2O), it features 11 selectable units of measure: inh20, psi, bar, mbar, kpa, inhg, mmhg,ozin
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
TOUCH SCREEN WEATHER STATION MODEL WS-3500. Operation Manual
TOUCH SCREEN WEATHER STATION MODEL WS-3500 Operation Manual 28 Table of Contents 1... General 2... Important Touch Screen Operating Notes generally applicable 3... Putting into Operation 3.1... Wiring
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7
focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7 Thank you for purchasing our product. Please read this manual carefully before operation your set and retain it for future reference. FT55-P10
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES
ELECTRONIC COUNTING SCALE Operation Manual l JCS- A SERIES CONTENTS I. Specification:... II. Operation:... III. Weight calibration:... IV. RS232 transmission confer Data format (optional) V. Regular trouble
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
NoiseMeters. www.noisemeters.com. dosebadge. Monitoring Personal Noise Exposure
NoiseMeters dosebadge Monitoring Personal Noise Exposure Small size and weight with simple operation No cables or controls on the dosebadge Reduces damage and tampering Very strong construction Meets IEC
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
EC4.8. BalancedReferencePreamplifier. Owner smanual ENG
EC4.8 BalancedReferencePreamplifier Owner smanual ENG Unpacking the EC 4.8 Immediately upon receipt of the EC 4.8, inspect the carton for possible damage during shipment. The carton and packaging have
reflecta Super 8 Scanner
reflecta Super 8 Scanner User Manual 1 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT This Equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
Professional Thermohygrometer
User Manual Professional Thermohygrometer with NIST-Traceable Calibration Model 20250-21 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Professional Thermohygrometer (Model 20250-21)
VIDEO DOOR PHONE SYSTEM
ENGLISH VIDEO DOOR PHONE SYSTEM USER MANUAL Manual covers IH-692 Master and IH-692 Slave Monitors PRECAUTIONS BEFORE INSTALLATION Connect this unit ONLY to other compatible units. Do not connect it to
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Paint Test Equipment. Stargloss Gloss Meter Data Sheet
Paint Test Equipment Stargloss Gloss Meter Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies with
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Dual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570 Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact
User Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances
Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
Light Meter (Foot Candles)
Light Meter (Foot Candles) 840021 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS 1. INTRODUCTION... 2 2. PANEL DESCRIPTION... 3 3. MEASUREMENT PROCEDURES... 4 4. ZERO ADJUSTMENT & CALIBRATION...
Register your product and get support at www.philips.com/welcome LFH0645 LFH0648. EN User manual
Register your product and get support at www.philips.com/welcome LFH0645 LFH0648 EN User manual Table of contents 1 Welcome 3 Product highlights 3 2 Important 4 Safety 4 Hearing safety 4 Disposal of your
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
WINGLIKE ELECTRONICS CO.,LTD
WINGLIKE ELECTRONICS CO.,LTD SPECIFICATION FOR APPROVAL AC/DC ADAPTOR CUSTOMER: CUSTOMER SPECS INPUT: 100-240V AC 50-60HZ, 5V/2A ADAPTOR OUR MODEL NO.: GM-050200 (UL) E321192 SPECIFICATION NO.: WL1105102
STERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
BASIC SOUND LEVEL METERS
BASIC SOUND LEVEL METERS Typical Applications: Occupational Noise Measurements Noise Ordinance Enforcement Community Noise Assessment Fire & Emergency Notification Alarm Testing Maintenance Inspections
How To Use A Meter
Table of Contents Title I UT391 Product Introduction II Unpacking Inspection III Safety Instruction IV Meter Structure V Setting and Operation of Meter VI Technical specifications VII Maintenance 3 4 5
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
TYPE 6224 Integrating Precision Sound Level Meter
TYPE 6224 Integrating Precision Sound Level Meter Instruction Manual (Version 1.6C) www.castlegroup.co.uk Thank you for buying a Castle product, I am sure you will find both the goods and the service to
Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage
Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming
