Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME



Similar documents
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Commissioning: What you need to know

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Sovereign. The made to measure data centre

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Overview Document

How To Write An Infrastructural Standard For Data Center Infrastructure

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

BICSI 002 / TIA 942 / Uptime

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

National Aluminium Co. Ltd.

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Building a Tier 4 Data Center on a Tier 1 Budget

EXAMPLE OF A DATA CENTRE BUILD

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

LEVEL 3 DATA CENTER ASSESSMENT

Element D Services Heating, Ventilating, and Air Conditioning

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

Product Overview. Swaminathan.S Business Development Manager

19 Site Location, Design and Attributes. Site Location, Design and Attributes

Data Center Designs and Hospital Operations

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Introduction to Datacenters & the Cloud

World s Greenest High Performance Data Center

The Pros and Cons of Modular Systems

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Onsite Support: 24/7/365 onsite team. Security: 24/7/365 onsite manned security and CCTV. Monitoring: 24/7/365 Environmental monitoring and management

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Data Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

Server Room, Data Centre Management and Monitoring Solutions

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

ASX Australian Liquidity Centre. ASXCoLo

OPERATOR - FACILITY ADDRESS - DATE

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Managing Cooling Capacity & Redundancy In Data Centers Today

CyberSafe has expanded to three companies in United Arab Emirates, Kingdom of Bahrain & India within a Short Span of Time.

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

Only a matter of power supply and air conditioning? Joachim Faulhaber TÜV Informationstechnik GmbH

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Data Center Presentation

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Center Infrastructure & Managed Services Outline

Data Center Solutions

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Elements of Energy Efficiency in Data Centre Cooling Architecture

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

The Region s Leading Data Center Developer, Manager and Operator C O R P O R A T E P R O F I L E

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Dealing with Thermal Issues in Data Center Universal Aisle Containment

HealthcareBookings.com Security Set Up

Previder Datacenters it starts here

DataCenter 2020: first results for energy-optimization at existing data centers

North Datacentre - Studley

COMMODITIZING THE DATA CENTER MARKET

Best Practices for Wire-free Environmental Monitoring in the Data Center

University of St Andrews. Energy Efficient Data Centre Cooling

Data center management suite. Providing optimal control and efficiency to data center management.

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

The Different Types of Air Conditioning Equipment for IT Environments

AIRAH Presentation April 30 th 2014

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Dedicated Hosting Services

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

News in Data Center Cooling

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Building a data center. C R Srinivasan Tata Communications

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Data Centers: Outsource or Own? Presented by: Rachel Dines, Forrester Research, Inc. Christopher Nicolini, Windstream Hosted Solutions

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering % uptime

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Technical specifications. Containerized data centre NTR CDC 40f+

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Recommendations for Measuring and Reporting Overall Data Center Efficiency

ASX ITS Co-location Hosting Solution

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Protecting Our Information, Protecting Our Resources

DATACENTER COLOCATION. Flexible, Secure and Connected

Colocation. Scalable Solutions for a Shared IT Infrastructure. Enterprise. Colocation

Green Data Centre Design

SLA. Co-Managed. Do-It-Yourself

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Specialty Environment Design Mission Critical Facilities

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Data Center Checklist

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

Subject: County of Los Angeles Data Center Space Requirement

Enterprise Remote Monitoring

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

Transcription:

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

2 AGENDA SESSION -1 What is Data Center? SESSION -2 Equipment and Components SESSION -3 Standard in designing Data Center SESSION -4 Professional Data Center Operation and Service (Maintenance)

3 NARA NONNAPHA DESIGN AND BUSINESS DEVELOPMENT, SITE PREPARATION MANAGEMENT Bachelor Electrical Engineer - University of Rhode Island, USA Data Center Experience - 6 years in Data Center Design Best Practice, Consultation, and fully study of Data Center Standards (TIA-942, BICSI002, UPTIME, and ASHRAE 9.9TC) - Electrical, Cooling, Fire Suppression, Security, Monitoring, and Planning References - Banking, Government, Telecommunications, Industries, etc.

4 SITE PREPARATION MANAGEMENT DESIGN AND BUILT DATA CENTER WHO IS SITEM? Mission Critical Facility Provider including Security, Monitoring, Data Center, SCADA, and Control Center 24x7 service and on duty. Complete solution for Electrical, Mechanical, Security System, Network, Fire Alarm, Fire Protection System, Building Automation System, Monitoring, and other physical security (outdoor) Largest site references in mission critical facility in Thailand.

5 SITE PREPARATION MANAGEMENT DESIGN AND BUILT DATA CENTER Key of Success SITEM is The leader of Professional Special Engineering & Absolutely Data Center Solution in Thailand and to be in SEA. We're 100% Thai people who establish Thai company to create innovation and technology in engineering of special application and data center field. ISO9001:2008 Certificate SITEM is certified ISO 9001:2008 standard from 2 auditors institute in scope for Design, Supply, Construction, Installation, Project Management and Maintenance of Turnkey and Facility products for Data Center, IT, Telecom, Server Room and Environment Control Area. Manufacturing of Monitoring and Detection System. We also applied and followed standard ISO 10006 for control our project management performance since 2008 to improve our project effectiveness.

6 SITE PREPARATION MANAGEMENT DESIGN AND BUILT DATA CENTER OUR TEAM

7 WHAT IS DATA CENTER A facility used to house computer systems and associated components, such as telecommunications and storage systems. It generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices. One of the main concerns is business continuity; companies rely on their information systems to run their operations. If a system becomes unavailable, company operations may be impaired or stopped completely. It is necessary to provide a reliable infrastructure for IT operations, in order to minimize any chance of disruption. Information security is also a concern, and for this reason a data center has to offer a secure environment which minimizes the chances of a security breach. A data center must therefore keep high standards for assuring the integrity and functionality of its hosted computer environment. This is accomplished through redundancy of both fiber optic cables and power, which includes emergency backup power generation. Credit: www.wikipedia.com

8 WHAT IS DATA CENTER A facility used to house computer systems and associated components, such as telecommunications and storage systems. It generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices. One of the main concerns is business continuity; companies rely on their information systems to run their operations. If a system becomes unavailable, company operations may be impaired or stopped completely. It is necessary to provide a reliable infrastructure for IT operations, in order to minimize any chance of disruption. Information security is also a concern, and for this reason a data center has to offer a secure environment which minimizes the chances of a security breach. A data center must therefore keep high standards for assuring the integrity and functionality of its hosted computer environment. This is accomplished through redundancy of both fiber optic cables and power, which includes emergency backup power generation.

9 DATA CENTER AROUND THE WORLD Credit: www.youtube.com

10 Equipment and Components Electrical Transformer, Switchgear, Main Distribution Board, UPS, Battery, cable, busduct, wireway, conduit, breaker, PDU, BCMS (Branch Circuit Monitoring System), Mechanical Chiller, Pump, Condenser, Cooling Tower, AHU, CRAC (Computer Room Air Conditioning), CRAH (Computer Room Air Handling), Refrigerant pipe, Chilled Water pipe, etc. Fire Protection System Sprinkler, Water Mist System, Gas Suppression System, ASD (Aspiration Smoke Detection System), Monitoring System BAS (Building Automation System), EMS (Environmental Monitoring System), DCiM (Data Center Infrastructure Management System), Water Leak Detection System, Video Wall, etc. Security System CCTV (Closed Circuit Television), Access Control, Security IT Room, Data Safe, Bollard, Road Blocker, Turnstile, Mantrap door, revolving door, Under Vehicle Inspection System, and X-Ray machine Architecture and Civil work Raised Floor, Wall, door, windows, and ceiling Network System Cabling, Computer Rack, and tracking system

MAJOR COMPONENT 11 UPS (Uninterruptible Power Supply) Static UPS - No Movement of components - Use battery to supply power during shortage of utility - Normally backup time 10-30 minute - Traditional and most popular Solution for Data Center Dynamic UPS - Moving Part - Use Flywheel to supply power during shortage of utility - Normally back up time 15 seconds - New trend of technology, not commonly used in Data Center but more efficient, save energy

MAJOR COMPONENT 12 UPS (Uninterruptible Power Supply) WHY FLYWHEEL? - More Efficient - No need for cooling - Less space Installation - Less Maintenance Credit: www.youtube.com

MAJOR COMPONENT 13 COMPUTER ROOM AIR CONDITIONING (CRAC) Supply Cold Air for Data Center Control Temperature and Humidity according to recommended set point at 18-27 Celsius and 45-65% RH Downflow or Upflow (more efficient using downflow) Chilled Water and Air Cooled System (Save energy to use Chilled Water)

MAJOR COMPONENT 14 COMPUTER ROOM AIR CONDITIONING (CRAC) Credit: www.youtube.com

15 COMPONENTS INSIDE CRAC UNIT Third generation CyberAir includes additional efficiency features: Optimization of the EC Fan Introduction of a compound fan wheel. Reduction of the fan power supply up to 15% compared with traditional EC fan technology plus reduction of the sound pressure level up to 5dB(A) Introduction of brushless DC compressors in close control air conditioning units Optimized part load behavior for indirect free cooling systems: Cooling capacity 17%-100% for single circuit units Cooling capacity 8,5%-100% for dual circuit units Operating cost savings up to 25% compared to DFC Systems Optional offering of a deeper rear panel additional reduction of the fan power consumption up to 20%

MAJOR COMPONENT 16 COMMON LAYOUT OF DATA CENTER

MAJOR COMPONENT 17 FIRE PROTECTION SYSTEM SPRINKLER Water Mist System Gas Suppression System - FM-200 - IG-100 - IG-55 - IG-541 NOVEC CO2 Aerosol

MAJOR COMPONENT 18 FIRE PROTECTION SYSTEM

MAJOR COMPONENT 19 FIRE PROTECTION SYSTEM Credit: www.youtube.com

MAJOR COMPONENT 20 ASPIRATION SMOKE DETECTOR Detects smoke at early stage Some users may call EARLY WARNING System To detect smoke in order to prevent gas system to discharge or water to discharge User may know and be notified at early time and become aware of the room risk of having fire.

MAJOR COMPONENT 21 ASPIRATION SMOKE DETECTOR Credit: www.youtube.com

MAJOR COMPONENT 22 MONITORING SYSTEM Building Automation System VISIBILITY Enhanced User Experience 1 2 Plant Energy Essentials & Chiller Plant Automation FLEXIBILITY 3 Hardware & Software Updates 4 CONNECTIVITY Enhanced Wireless Capabilities SECURITY Security & Fire Safety 5 6 SUSTAINABILITY Connect to Smart Phone

MAJOR COMPONENT 23 MONITORING SYSTEM Data Center Infrastructure Management (DCiM) Temperature Humidity Pressure Leak Detection Dry Contact Equip Status CW BTU Power Particle Count

Rack/Cabinet Temperature & Humidity DCiM CRAC/CRAH Temperature & Humidity For Supply and Return Panel Power Energy or Current PDU Branch Circuit Monitoring CONFIDENTIAL Subfloor Pressure Differential Cooling Pipes Flow & Temperature

MAJOR COMPONENT 25 MONITORING SYSTEM Water Leak Detection System WATER LEAK DETECTOR - Detects water - Protect area such as raised floor and ceiling or shaft - Specify location of detection or leakage of water - Accuracy for easy use and monitoring - Touch screen or monitor via smart phone - Remote monitoring

MAJOR COMPONENT 26 ELECTRICAL COMPONENTS BCMS (BRANCH CIRCUIT MONITORING SYTEM) - Measure power and current of each circuit of computer rack - Monitor and set alarm for each circuit - Energy Billing for Co-Location Data Center Power Strip with IP BCMS

MAJOR COMPONENT NETWORK AND CABLING 27 CABLING - Optical Fiber - UTP COMPUTER RACK - Standard Rack - Special Rack TRACKING DEVICE

MAJOR COMPONENT NETWORK AND CABLING 28 Credit: www.youtube.com

MAJOR COMPONENT 29 VIDEO WALL Consists of many screens Shows many applications at one time such as Server, Video, CCTV, BAS, Application, etc. LCD, LED, and DLP Technology

MAJOR COMPONENT 30 VIDEO WALL Credit: www.youtube.com

MAJOR COMPONENT 31 SECURITY Outdoor - Folding Gate - Gate Barrier - UVIS - Bollard - Road Blocker - Car Park Management Indoor - Revolving door - Turnstile - X-Ray Machine - Mantrap door - CCTV - Access Control

MAJOR COMPONENT SECURITY 32

33 STANDARDS IN DESIGNING DATA CENTER TIA-942 BICSI002 UPTIME TUV

MAJOR STANDARDS BICSI AND TIA-942 by ANSI 34 Principles - Specify the minimum requirements for telecommunications infrastructure of data centers and computer rooms including single tenant enterprise data centers and multi-tenant Internet hosting data centers. - Identify types of Data Center - Tier 1, Tier 2, Tier 3, and Tier 4 - Non-Profitable organization

MAJOR STANDARDS TIER 1 according to TIA-942 35 Utility ATS Generator Electrical Distribution Mechanical Switchgear UPS PDU Non Critical Load AIR CON Critical Load

MAJOR STANDARDS TIER 2 according to TIA-942 36 Utility ATS Generator Generator Electrical Distribution Static Bypass UPS UPS Mechanical Switchgear PDU Non Critical Load AIR CON AIR CON Critical Load

MAJOR STANDARDS TIER 3 according to TIA-942 37 Utility Electrical Distribution ATS Generator Generator Electrical Distribution Static Bypass Output Dist. Board Mechanical Switchgear Air Condition (Redundant) Mechanical Switchgear Static Bypass UPS UPS Output Distribution Board PDU PDU Critical Load

TIER 4 according to TIA-942 38 Utility Utility Generator Generator ATS Generator ATS Generator Electrical Distribution Electrical Distribution Static Bypass Mechanical Switchgear Mechanical Switchgear Static Bypass UPS UPS UPS UPS Air Condition (Redundant) Output Distribution Board Output Distribution Board PDU Critical Load PDU

MAJOR STANDARDS UPTIME INSTITUTE 39 Principles - Equip design professionals, data center operators, and non-technical managers with an objective and effective means for identifying the anticipated performance of different data center site infrastructure design topologies. - First institute to identify Tier level - Tier I, Tier II, Tier III, and Tier IV - Profitable Organization - Many type of Data Center services: Design Certification, Construction Certification, Site Analysis, Operational Sustainability, ATD (Accredited Tier Designer), and ATS (Accredited Tier Specialist).

MAJOR STANDARDS TIER 1 according to UPTIME Main Distribution A Air Distribution A Computer Room Cooling A Utility Chilled Water Plant A House Power A Gen N Engine Generator System Capacity UPS Input Bus A UPS System A N UPS System Capacity Critical Distribution Bus A

MAJOR STANDARDS TIER 2 according to UPTIME Main Distribution A Air Distribution A Computer Room Cooling A Utility Chilled Water Plant A Gen House Power A Gen N+ Engine Generator System Capacity UPS Input Bus A UPS System A N+ UPS System Capacity (minimum) Critical Distribution Bus A

MAJOR STANDARDS TIER 3 according to UPTIME Main Distribution A Air Distribution A Computer Room Cooling A Utility Chilled Water Plant A House Power A Gen Gen UPS Input Bus A UPS System A Computer Room Cooling B Critical Distribution Bus A Critical Distribution Bus B Air Distribution B Chilled Water Plant B House Power B

Fault Tolerant Electrical Backbone Air Distribution A Main Distribution A Computer Room Cooling A Utility Chilled Water Plant A House Power A Gen UPS Input Bus A UPS System A Critical Distribution Bus A Gen Air Distribution B Main Distribution B Computer Room Cooling B Utility Chilled Water Plant B House Power B UPS Input Bus B UPS System B Critical Distribution Bus B

44 Data Center Operation and Service IMPORTANCE OF DATA CENTER MAINTENANCE - Data Center owners, operators, managers and IT people should be aware of the prioritized behaviors and risks intrinsic to Data Center operations. - Adherence to the recommended behaviors will assist in attaining the full performance potential of the installed infrastructure. - UPTIME provide Data Center Maintenance or Operation Certification - BIG PICTURE -> LONG LIVE DATA CENTER (SUSTAINABILITY)!

45 Data Center Operation and Service Level of Data Center Operational Sustainability - GOLD - SILVER - BRONZE A GOOD SOLID DESIGNED DATA CENTER MAY NOT HAVE GOOD OPERATION AND SHORT LIFE OF AVAILABILITY!

46 Data Center Operation and Service WHAT TO LOOK AT - Management & Operations (Staff and Organization, Maintenance, Training, and Planning, Coordination, and Management) - Building Characteristics (Building features, Infrastructure, Operating Conditions, and Pre Operational) - Site Location (Natural Disasters and Man-Made Disasters)

47 Q & A Nara Nonnapha SITE PREPARATION MANAGEMENT Mobile: +6690 198 2100 Email: Naran@sitem.co.th