How To Write An Infrastructural Standard For Data Center Infrastructure

Similar documents
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

TIA-942 Data Centre Standards Overview WHITE PAPER

Telecommunications Infrastructure Standard for Data Centers Tutorial

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Building a Tier 4 Data Center on a Tier 1 Budget

Data Centre Design ready for your future

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Data Centre Issues supported in TIA-942 : "Telecommunications Infrastructure for Data Centre s"

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942

How To Visit An Internet Data Center

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

OPERATOR - FACILITY ADDRESS - DATE

** PROPRIETARY ** SAMPLE COUNTY DATA CENTER PROJECT BUDGET ** PROPRIETARY **

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM

NeuStar Ultra Services Physical Security Overview

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Data Center Design Considerations

TIA STANDARD. Telecommunications Infrastructure Standard for Data Centers TIA-942 TELECOMMUNICATIONS INDUSTRY ASSOCIATION

Data Center Presentation

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Commissioning: What you need to know

Subject: County of Los Angeles Data Center Space Requirement

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Data Center Designs and Hospital Operations

Corning Cable Systems Optical Cabling Solutions for Brocade

DATACENTER COLOCATION. Flexible, Secure and Connected

Data Center Design for 40/100G

Zone Distribution in the Data Center

Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Keyword: TIA 942, Tier level, Nuclear Data Center. Introduction

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering % uptime

TIA-942: Data Center Standards

Network Design. Yiannos Mylonas

Data Centre Reliability and Redundancy. What do they mean and are you are getting what you need?

UC Berkeley Data Center Overview

Data Center Overview Document

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

Data Center Infrastructure & Managed Services Outline

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

19 Site Location, Design and Attributes. Site Location, Design and Attributes

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

Assessment of Existing Data Centers for Critical Facilities Round Table Group

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

Products. Technology. Services. Delivered Globally. DATA CENTER SOLUTIONS

Corning Cable Systems Optical Cabling Solutions for Brocade

Data Center Security 100% UPTIME PUZZLE. Page 1

Scalable. Affordable. Flexible. Fast.

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

BICSI Data Center Standard. Presented by: Stephen Banks, RCDD CDCDP

Data Center Colocation Build vs. Buy

Electrical. This section applies to the design and installation of building power distribution systems.

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

N O W A V A I L A B L E

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

How To Buy Anixter Data Center

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

DATA CENTRE DATA CENTRE MAY 2015

Data Center Topology Guide

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

COMMODITIZING THE DATA CENTER MARKET

Data Center Design Considerations. Walter P. Herring, RCDD/LAN/OSP Senior Systems Specialist Bala Consulting Engineers, Inc.

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Experience Matters...

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

DESIGN GUIDELINES. Local Area Network

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

Specifying an IT Cabling System

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Transcription:

Infrastructure Standard for Data Centers ANSI/CSA/EIA/TIA-942 (PN-3-0092)

Introduction When approved, the standard will be: ANSI/CSA/EIA/TIA-942 Telecommunications Infrastructure Standard for Data Centers An official U.S. and Canadian standard for data center infrastructure ANSI American National Standards Institute CSA Canadian Standards Association EIA Electronics Industries Alliance TIA Telecommunications Industry Association The basis for an international standard by the ISO

Who is Developing the Standard The standard is being developed by the TIA TR-42.1.1 Committee as Project No. 3-0092. 3 Participants include more than 60 organizations including: Architecture & Engineering Firms Manufacturers Consultants End Users Most of the content was contributed by a small team of experts, but is reviewed by a large audience including industry organizations.

Major Contributors TELECOM ARCHITECTURAL ELECTRICAL MECHANICAL STRUCTURAL FIRE SUPPRESSION SECURITY J & M CONSULTANTS, INC. GYZEN & ASSOCIATES ARCHITECTS EYP MISSION CRITICAL FACILITIES, INC. EYP MISSION CRITICAL FACILITIES, INC PARADIGM STRUCTURAL ENGINEERS, INC. DIVERSIFIED PROTECTION SYSTEMS, INC. INTEGRATED SECURITY SYSTEMS, INC.

Status of the Standard 1 st official draft was completed in Feb 2003. Committee will review and vote on the 1 st round of comments this June 2003. The document is currently only available to committee members, contributors, and related standard setting organizations. The 7x24 Exchange submitted favorable comments regarding the 1 st draft. Under review by the Uptime Institute. Final approval expected sometime in 2004.

Purpose of the Standard Fill a void by providing standards for planning of data centers, computer rooms, co-location centers, trading floor equipment rooms, technology test labs, and similar spaces. The standard encompasses much more than just telecommunications infrastructure. Approximately half of the technical content deals with facility specifications.

Computer Room Requirements Architectural Location Ceiling Height Treatment Doors Floor Loading Raised floor systems Environmental/HVAC HVAC Contaminants Vibration Fire Protection Electrical Power Standby Power Bonding & Grounding

Structured Cabling System A single flexible cabling system to handle a wide range of current and future technologies including LAN, WAN, SAN, FICON, ESCON, and console technologies. Simple documentation, management, and expansion. TIA-606 standards compliant labeling scheme for all components. Provision for redundant components and cabling

Structured Cabling System Offices, Operations Center, Support Rooms Telecom Room (Office & Operations Center LAN switches) Horiz Dist Area (LAN/SAN/KVM Switches ) Zone Dist Area Carriers Horiz Dist Area (LAN/SAN/KVM Switches ) Entrance Room (Carrier Equip & Demarcation) Main Dist Area (Routers, Backbone LAN/SAN Switches, PBX, M13 Muxes) Carriers Computer Room Optional Backbone Cabling Horiz Dist Area (LAN/SAN/KVM Switches ) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet) Equip Dist Area (Rack/Cabinet)

Telecommunications Infrastructure Guidelines for equipment placement Cabinet specifications Guidelines regarding selecting cable types: Cat 5e UTP, Cat 6 UTP, 734 coax, 50/125 multimode fiber, single-mode fiber Guidelines for max lengths over the cabling system - limits equipment placement & computer room size (not available in any other standard ) E1, T1, E3, T3, TIA-232, TIA-561/562, FibreChannel, Gigabit Ethernet, 10 Gigabit Ethernet Carrier coordination & demarcation

Site Selection Guidelines for selection of a site for a data center Architectural ElectricalElectrical Mechanical Telecommunications SecuritySecurity OtherOther

Facilities Specifications & Tiers General requirements & tier specifications for each discipline (higher tier = higher availability) Tier 1 basic data center no redundancy Tier 2 redundant components Single distribution path with redundant components Tier 3 concurrently maintainable Multiple distribution paths with only one active Tier 4 fault tolerant Multiple active distribution paths

Architectural Site requirements Parking Multi-tenant tenant Occupancy within Buildings Building Construction Building Components Doors and Windows Entry Lobbies Administrative Offices Security Offices Operations Centers Restrooms and Break Room Areas UPS and Battery Rooms Required Exit Corridors Shipping and Receiving Areas Generator and Fuel Storage Areas

Electrical Number of Delivery Paths Utility Entrances System Allowances for Concurrent Maintenance Equipment Power Cords Equipment 3 rd Party Certification Labels Single Points of Failure Critical Load System Transfer Site Switchgear Standby Generating Systems a. Generators Sized Correctly b. Fuel Capacity (at full load) UPS a. Redundancy b. Topology c. Maintenance Bypass Arrangement d. Power Distribution Voltage Level e. Power Distribution Panel Boards f. Rotating UPS System Enclosures

Electrical PDUs Grounding Computer Room EPO Systems Battery Room EPO Systems System Monitoring Battery Rooms Battery Configurations Loadbanks for Testing Equipment Maintenance

Mechanical General System Types a. Water-Cooled Systems b. Chilled Water Systems c. Air-Cooled Systems HVAC Control Systems Plumbing (for water-cooled heat rejection) Fuel Oil Systems

Structural Seismic Zones Site Specific Response Spectra Importance Factors Anchoring of Equipment Deflection Limitation on Equipment Bracing Floor Loading Capacities Floor Hanging Capacities Building Structural Components Building Energy Dissipation (Passive Dampers/Base Isolation)

Fire Suppression Fire Detection Systems Fire Sprinkler Systems Gaseous Suppression Systems Early Warning Smoke Detection Systems Water Leak Detection Systems

Security Security Access Control/Monitoring at: a. Generators b. UPS, Telephone & MEP Rooms c. Fiber Vaults d. Emergency Exit Doors e. Accessible Exterior Windows/Openings f. Security Operation Centers g. Network Operation Centers h. Security Equipment Rooms i. Doors into Computer Rooms j. Perimeter Building Doors k. Doors from Lobby to Data Center Floor Bullet Resistant Walls, Windows, and Doors CCTV Monitoring CCTV Recording of All Activity on All Cameras

Telecommunications Cabling system meets standard specifications Carrier entrance facility diversity Carrier right-of of-way diversity Redundant cabling Redundant routers and switches Labeling of patch panels and outlets Labeling of patch cords Cabling system documentation

What Does It All Mean? TIA-942 is the first official standard for data center infrastructure. Primarily a telecom infrastructure standard, but about half of the content deals with facility requirements. Provides a flexible and manageable structured cabling system using standard media. Guidelines on a wide range of subjects useful to someone designing or managing a data center. An official tiering standard for determining the quality of a center. A way to objectively compare one center with another.