Installation. Basic Rack Power Distribution Unit for Blade Servers

Similar documents
Installation. Metered Rack Power Distribution Unit

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Installation. Basic Rack Power Distribution Unit AP9559

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

Rack installation instructions

HP 16/18-Port Cable Management Kit Installation Guide

Raritan LCD KVM Console (T1700/T1900)

Rack Installation Instructions

Raritan LCD KVM Console (T1700/T1900)

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Metered Rack Power Distribution Unit

Rack Systems Solutions

Unpacking, Installation, and Customization

Rack Installation Instructions

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Secure your IT equipment with confidence... secure with NetClosure

Cabinets 101: Configuring A Network Or Server Cabinet

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

UPGRADING AND SERVICING GUIDE

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

RACK ENCLOSURES & ACCESSORIES

Installation Instructions

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

AU-110 racking guide NBXPN: 023

Installation. Switched Rack Power Distribution Unit

Processor Cage Fans, Front and Rear Replacement Instructions

About the HotWire Slot Standalone Shelf

42U/45U 28" Wide Rack Installation & Service Guide

How To Power A Bladecenter H Servers

Unpacking, Installation, and Customization

AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Rack Power Distribution. Worldwide

Installing Your 960 or 980 Server into a Rackmount Cabinet

InstaPATCH ZERO Solution Guide

Customized Server Cabinets

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Cabinet V800 V800 CABINETS

ASKING FOR ASSISTANCE

Removing memory and option cards

HP UPS R1500 Generation 3

Front Panel Board Cable Replacement Instructions

Unpacking, Installation, and Customization Manual

Rack Power Distribution

FIELDPOINT BUS EXTENDER CABLE

Unpacking, Installation, and Customization Manual. NetShelter SX Enclosure

Quadrant Shower Enclosure. Telephone Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

RACKMUX-DRAWER Installation Manual For Drawer with 20 Inch LCD Monitor

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

About the BitStorm 6051 POTS Splitter

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

16/32 Channel 1U Rack Mount CCTV Power Supply

Installation Instructions

PS6500 Storage Arrays Rack Mount Instructions

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

GSM-EXT Cable Assembly Installation Guide

How to Set Up Your NSM4000 Appliance

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

RACK ENCLOSURES AND OPEN FRAME RACKS FOR SERVER AND NETWORKING APPLICATIONS IN IT ENVIRONMENTS

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

INSTRUCTIONS: LocknCharge Laptop Carts

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

HermanMiller Aeron Posturefit Installation AE905A AE905B AE905C

Power Distribution Considerations for Data Center Racks

Installing your upgrade processor

How To Install A Power Supply (Uplast) With A Battery Pack

Power Commander Power Distribution Units from Wiremold/Legrand offer

POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

The power module is Feature Number 8800-F2-901.

Service Guide. Gateway M275

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

DCF Optimized Rack System Selection Guide

Replacing an AC Power Cord in a Power Shelf

Installation Instructions For Slider Casement Air Conditioners

Basic Spring Motor Roller Shades

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Hollow or Cinder Block Wall Mount Job Aid

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

ATS Overhead Table Shelf System INSTRUCTION MANUAL

How To Fit A Dll 2420 And 4220 Rack Enclosure

Installation and Quick Configuration

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

DCF Optimized Rack System

HotLok Pass Through Blanking Panel

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

HP NetServer LH 3000r Rack Cabling Reference Guide

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

ADC-APC Integrated Cisco Data Center Solutions

Transcription:

Installation Basic Rack Power Distribution Unit for Blade Servers

Contents Preliminary Information...................1 Features............................. 1 Receiving inspection................... 1 Please recycle........................ 1 How to Install the Rack PDU...............2 Attach the cord retention tray............ 2 Attach cords to the tray................. 2 Mounting options...................... 3 Toolless mounting..................... 3 Bracket mounting...................... 4 Basic Rack PDU for Blade Servers i

Preliminary Information Features This booklet provides information on installing and operating Basic Rack PDU. Receiving inspection Inspect the package and contents for shipping damage, and make sure that all parts were sent. Report any damage immediately to the shipping agent, and report missing contents, damage, or other problems immediately to us. Please recycle The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately. Basic Rack PDU for Blade Servers 1

How to Install the Rack PDU Attach the cord retention tray Attach the cord retention tray to the Rack PDU, using four flat-head screws (provided). Attach cords to the tray Attach a cord to the tray by looping the cord and securing it to the tray, using a wire tie (provided). pdu0341a Note. When you secure the cord to the tray, ensure that you can unplug the cord from the Rack PDU without removing the wire tie. Note. When installing the Rack PDU, ensure that the power cord plug is accessible and that it is connected to a grounded outlet. You can mount four Rack PDUs on one side of the enclosure by using the toolless mounting method. 2 Basic Rack PDU for Blade Servers

Mounting options You can install the vertical 0-U Rack PDU in one of two ways: using toolless mounting pegs (provided) or mounting brackets (provided). The 1-U horizontal Rack PDU must be mounted using the horizontal mounting brackets (provided). Vertical mounting. To install the Rack PDU using the toolless mounting method, install it in the rear of the NetShelter VX or SX Enclosure, in the cable channel directly behind the rear vertical mounting rails. To install the Rack PDU using the mounting brackets, install it on a vertical mounting rail on your rack or enclosure. Horizontal mounting. To install the Rack PDU using the horizontal mounting brackets, install the brackets on the Rack PDU and then attach the brackets to the rack using caged nuts (provided with your enclosure). Toolless mounting 1. Slide both mounting pegs into the holes located in the channel in the rear panel of the enclosure. 2. Snap the Rack PDU into place by pushing it downward until it locks into position. pdu0342a Note. You can mount four Rack PDUs on one side of the enclosure by using the toolless mounting method. Basic Rack PDU for Blade Servers 3

Bracket mounting Vertical mounting. To mount the Rack PDU vertically in a NetShelter or any standard EIA-310 rack or enclosure: 1. Attach the vertical-mounting brackets to the Rack PDU. Caution. Use only the supplied screws. 1. Install the Rack PDU on a vertical mounting rail in your rack or enclosure using the supplied screws and caged nuts. pdu0190b pdu0344a Note. You can mount two Rack PDUs on one side of the enclosure by using the vertical mounting brackets. 4 Basic Rack PDU for Blade Servers

Horizontal mounting. You can mount the Rack PDU in a 19-inch NetShelter enclosure or other EIA-310-D standard 19-inch rack. 1. Choose a mounting position for the Rack PDU with either the display or the rear facing out of the enclosure. 2. Attach the mounting brackets to the Rack PDU, using the flat-head screws (provided). 3. Choose a location for the unit: Note. The unit occupies one U-space. A notched hole on the enclosure s vertical rail indicates the middle of a U- space a. Insert a caged nut (provided with the enclosure) above and below a notched hole on each vertical mounting rail in your chosen location. b. Align the mounting holes of the brackets with the installed caged nuts. Insert and tighten screws. pdu0353a pdu0352a Basic Rack PDU for Blade Servers 5

Recessed horizontal mounting. You can mount the Rack PDU in a recessed configuration by attaching the brackets in alternate positions on the PDU, as shown below. 6 Basic Rack PDU for Blade Servers