Push button 3gang standard flush-mounted 751633xx



Similar documents
Light scene push button 8gang comfort flush-mounted xx

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

How To Use A Power Supply On A Powerline 2.2 (Ai)

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

KNX Gateway RGK E-01

Product and functional description

Inwall 4 Input / 4 Output Module

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Busch-Watchdog Presence EIB Type:

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Transmitter Actuator 230V wave UP 560. Operation

Operating instructions. RCD flat 4-fold, 6-fold

ABB i-bus KNX SA/S Switch Actuators Product Manual

Tebis application software

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

Inwall Room Temperature Unit

Movement/monitoring 1307/1.0 (6325xx)

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Unica for KNX system 226

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

instabus KNX / EIB System System E F G H

Technical Manual MDT Rain sensor

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Instruction Manual Service Program ULTRA-PROG-IR

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Combi B Alarm box. Mounting instructions

Application software. Fan coil actuator 2gang RMD. Electrical / Mechanical characteristics : see product information

Product and Application Description

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a

Quick Connect. quick - simple - efficient.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Configuration example: Scene function in the actuator channel in the ETS. 1 Introduction

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX i-bus Tool Product Information

Installation Instructions. ThermoCall TC4. Entry/Advanced

ABB STOTZ-KONTAKT GmbH. ABB i-bus KNX Weather Unit, Weather Sensor

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Application Unit, MDRC AB/S 1.1, GH Q R0111

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Installation Instructions. Thermo Call TC3

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S , GH Q R0111. ABB i-bus EIB / KNX

DS1621 Digital Thermometer and Thermostat

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

Z-Wave.Me Wall Controller

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

ETS4 Diagnostics. KNX Association

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Arcus-EDS Product Description LCD-Color-Display

Belimo Gateway MP to Modbus RTU - UK24MOD

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ABB i-bus EIB / KNX Room Controller

Wind Sensor W-RS485 with RS485 Interface

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Application software. 3-channel LED KNX controller Electrical / Mechanical characteristics : see product information. Application software ref.

DS1621 Digital Thermometer and Thermostat

Safety technique. Emergency stop module BO 5988 safemaster

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

KNX/EIB Product documentation. Master Control. Issue: x. Order-No X Page 1 of 222

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Multi-Protocol decoder with Load regulation

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

2013 Wireless Video Intercom INSTALLATION GUIDE

Multi-Protocol decoder

wdali Remote Datasheet DALI RF Remote Control Wireless DALI control unit with 12 programmable momentary switches

Functions module / Gateways. KNX-GW-RS232-RS485 Product Group 1

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

Mounting and Operating Instructions. TV gateway

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Combi switchbox with integrated 3/2 way pilot valve

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Mureva Assembly surface mounted wiring devices

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

15 Series - Electronic step relay and dimmer. Features SERIE

TMS TANK MANAGEMENT SYSTEM

Technical description MX-1 VB Edge

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Transcription:

Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard is plugged onto a bus coupling unit (BCU) (cf. connection diagram). After a press on the key, the push button sensor will transmit software-dependent telegrams to the KNX / EIB. These may be telegrams for switching, push button operation, dimming or for shutter control. It is also possible to program value transmitter functions such as dimming value transmitter or light-scene extension units. A white operation LED can serve as orientation lighting. Layout Dimensions Controls A B T1 T2 Width: 70 mm Height: 55 mm Depth: 13 mm (without PEI) A: 3 rockers or 6 push buttons (position: left / right) B: 3 x 2 status-led (red) C: 1 x Operation-LED (white) T3 T4 T5 T6 C Data Type of protection IP 20 Safety class III Mark of approval KNX / EIB Ambient temperature: -5 C... +45 C Storage / transport temperature -25 C... +70 C (storage above +45 C reduces the lifetime) Mounting position any Minimum distances: none Type of fastening plugging onto BCU KNX / EIB supply Voltage 21 32 V DC (SELV) via BCU Power consumption: typically 150 mw Connection: 2 x 5 pole pin contact strip External supply --- Gebr.Berker 2006 Version: 29.06.2006 Page: 1 / 9

Documentation Response to bus voltage failure Bus voltage only: object values are deleted, LEDs extinguished Response on return of bus voltage: Bus voltage only: no reaction Input: --- Output: --- Connection and terminals: C A B KNX / EIB A: push button standard 3gang B: physical external interface (PEI) C: bus coupling unit (BCU) Hardware remarks --- Gebr.Berker 2006 Version: 29.06.2006 Page: 2 / 9

Documentation Software description ETS search path ETS symbol Push button / Push button 3gang / Push button 3gang standard n PEI type 04 Hex 4 Dez 2 inputs / 2 outputs Applications: No. Summarized description: Name: Version: 1 Switching, status Switching, status 107901 0.1 2 Switching, acknowledge Switching, acknowledgement 107A01 0.1 3 Dimming Dimming 107C01 0.1 4 Shutter Shutter 107B01 0.1 5 Value transmitter Value transmitter 107D01 0.1 Gebr.Berker 2006 Version: 29.06.2006 Page: 3 / 9

Documentation Application: 1. Switching, status 107901 Number of addresses (max): 13 dynamic table handling: Yes No Number of assignments (max): 13 maximum length of table: 26 Communication objects: 3 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 0-2 Switching: 1-bit object for the transmission of switching telegrams (, ) Function of operating LED and of status LED parameterizable Command on key press parameterizable (, ) Function of the operating LED Defines the status of the operation LED. Function of the status LEDs Command at operation the left push buttons Command at operation the right push buttons Defines the status of the status LED. Defines the command transmitted on pressing the left push buttons (key 1/3/5). Defines the command transmitted on pressing the right push buttons (key 2/4/6). Software remarks The status LED indicates the current status of the switching object. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated, but the corresponding status LED is not lit up. Gebr.Berker 2006 Version: 29.06.2006 Page: 4 / 9

Documentation Application: 2. Switching, acknowledge 107A01 Number of addresses (max): 10 dynamic table handling: Yes No Number of assignments (max): 10 maximum length of table: 20 Communication objects: 3 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 0 2 Switching: 1-bit object for the transmission of switching telegrams (, ) Function of operating LED and of status LED parameterizable Command on key press parameterizable (, ) Function of the operating LED Defines the status of the operation LED. Function of the status LEDs Defines the status of the status LED. Light duration of the status LEDs (push button 1 6) 0.75 s 1.5 s 2.25 s 3.0 s 4.5 s 6.0 s 10 s 15 s Defines the time during which the status LED is on in case of a positive acknowledgement of receipt from an addressed actuator. Command at operation the left push buttons Defines the command transmitted on pressing the left push buttons (key 1/3/5). Command at operation the right push buttons Defines the command transmitted on pressing the right push buttons (key 2/4/6). Software remarks The status LED is on for a parameterizable time in case of a positive acknowledgement from an addressed actuator. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated, but the corresponding status LED is not lit up. Gebr.Berker 2006 Version: 29.06.2006 Page: 5 / 9

Documentation Application: 3. Dimming 107C01 Number of addresses (max): 12 dynamic table handling: Yes No Number of assignments (max): 12 maximum length of table: 24 Communication objects: 6 0 Switching Push buttons 1 and 2 1 bit C, W, T 1 Switching Push buttons 3 and 4 1 bit C, W, T 2 Switching Push buttons 5 and 6 1 bit C, W, T 4 Dimming Push buttons 1 and 2 4 bit C, T 5 Dimming Push buttons 3 and 4 4 bit C, T 6 Dimming Push buttons 5 and 6 4 bit C, T 0-2 Switching: 1-bit object for the transmission of switching telegrams (, ) 4-6 Dimming: 4-bit object for change of relative brightness between 0 and 100 % Function of operating LED and of status LED parameterizable Function of the operating LED Defines the status of the operating LED. Function of the status LEDs Defines the status of the status LED. Software remarks The status LED indicates the current status of the switching object. If a key is pressed (e.g. ) and if the push button sensor does not get a positive acknowledgement (IACK) from an addressed actuator, the object status is updated and the corresponding status LED is lit up. Gebr.Berker 2006 Version: 29.06.2006 Page: 6 / 9

Documentation Application: 4. Shutter 107B01 Number of addresses (max): 12 dynamic table handling: Yes No Number of assignments (max): 12 maximum length of table: 24 Communication objects: 6 0 Step operation Push buttons 1 and 2 1 bit C, W, T 1 Step operation Push buttons 3 and 4 1 bit C, W, T 2 Step operation Push buttons 5 and 6 1 bit C, W, T 4 Move operation Push buttons 1 and 2 1 bit C, W, T 5 Move operation Push buttons 3 and 4 1 bit C, W, T 6 Move operation Push buttons 5 and 6 1 bit C, W, T 0-2 Step operation: 1-bit object for step (short-time) operation of a shutter 4-6 Move operation: 1-bit object for move (long-time) operation of a shutter Important: Unused communication objects must be projected with dummy group addresses. Otherwise risk of malfunctions. Function of operation LED parameterizable Time between two telegrams (time between STEP and MOVE) presettable Function of the operating LED Defines the status of the operating LED. Push buttons 1 and 2 Time between two telegrams, base Time between two telegrams, factor (3...127) 130 ms (fixed) Defines the time base between two telegrams. (time between STEP and MOVE) Time = base factor 3... 127; 3 Defines the time factor between two telegrams. (time between STEP and MOVE) Time = base factor Presetting: 130 ms 3 = 390 ms Push buttons 3 and 4 See push buttons 1 and 2 Push buttons 5 and 6 See push buttons 1 and 2 Gebr.Berker 2006 Version: 29.06.2006 Page: 7 / 9

Documentation Application: 5. Value transmitter 107D01 Number of addresses (max): 1 dynamic table handling: Yes No Number of assignments (max): 1 maximum length of table: 2 Communication objects: 1 0 Value / light-scene Rockers 1 byte C, T 0 Value / light-scene 1-byte object for transmitting value telegrams of for recalling lightscenes Function of operating LED and of status LED parameterizable Mode of operation (value transmitter / light-scene recall with / without storage function) freely selectable Values (1 byte) or light-scene numbers (1...8) for all keys individually parameterizable Function of the operating LED Defines the status of the operation LED. Function of the status LED Operating mode Value transmitter Recall light-scene without memory function Recall light-scene with memory function Defines the status of the status LED. Defines the function of the push button sensor. Push buttons 1 and 2 with "Operating mode = value transmitter" 0... 255; 1 Defines the value transmitted when the 0... 255; 4 Defines the value transmitted when the Push buttons 1 and 2 with "Operating mode = recall light-scene with / without memory function" 1... 8; 1 Defines the value transmitted when the 1... 8; 4 Defines the value transmitted when the Push buttons 3 and 4 with "Operating mode = value transmitter" 0... 255; 1 Defines the value transmitted when the Gebr.Berker 2006 Version: 29.06.2006 Page: 8 / 9

Documentation 0... 255; 4 Defines the value transmitted when the Push buttons 3 and 4 with ""Operating mode = recall light-scene with / without memory function" 1... 8; 1 Defines the value transmitted when the 1... 8; 4 Defines the value transmitted when the Push buttons 5 and 6 with "Operating mode = value transmitter" 0... 255; 2 Defines the value transmitted when the 0... 255; 5 Defines the value transmitted when the Push buttons 5 and 6 with ""Operating mode = recall light-scene with / without memory function" 1... 8; 2 Defines the value transmitted when the 1... 8; 5 Defines the value transmitted when the Software remarks Light-scene extension unit: When a key is pressed for more than 1 s, the parameterized light-scene is recalled and the pertaining status LED switched on for about 1 s. If a key is pressed during a light-scene recall with storage function for more than 5 s, a storage telegram corresponding to the parameterized light-scene will be transmitted and the status LED is lit up for 4 s. Pressing a key with storage function for a time between 1 s and 5 s is without effect. The status LED lights up after a key-press only in conjunction with a positive acknowledgement (IACK) from an addressed actuator. Value transmitter: The status LED lights up after a key-press only in conjunction with a positive acknowledgement (IACK) from an addressed actuator. Gebr.Berker 2006 Version: 29.06.2006 Page: 9 / 9