Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances



Similar documents
AU-110 racking guide NBXPN: 023

HP UPS R1500 Generation 3

AvediaServer c1500 series Chassis. Installation Guide

Rack Installation Instructions

AvediaServer Chassis Installation Guide

Rack installation instructions

Installing Your 960 or 980 Server into a Rackmount Cabinet

DIVAR IP U DIP N, DIP HD, DIP HD. en Quick Installation Guide

42U/45U 28" Wide Rack Installation & Service Guide

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

DIVAR IP U DIP N, DIP HD, DIP HD. en Installation Manual

PS6500 Storage Arrays Rack Mount Instructions

MCR1900 Media Converter 19-Slot Chassis

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

About the HotWire Slot Standalone Shelf

SUPER USER S MANUAL. SC523 Chassis Series SC523L-520B SC523L-410B. 1.0a

HP R12000 and R18000 DirectFlow UPS User Guide

M86 Security Reporter Appliance INSTALLATION GUIDE Models: 300, 500, 505, 700, 705, 730, 735. Software Version: Document Version:

Installation Instructions

Cisco Physical Security Multiservices Platform Series User Guide

Rack Installation Instructions

Five9NS R2100RS Rack Mount Server. Installation Manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

How To Install A Power Supply (Uplast) With A Battery Pack

Tyan Computer. Transport PX22. Service Engineer s Manual

Installation. Basic Rack Power Distribution Unit for Blade Servers

Rackable Systems S3012 3U STORAGE SERVER FIELD SERVICE MANUAL. Revision 1.0. S3012-Service-Manual-1.0 Oct. 10, 2004 Page 1 of 15

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Installation Instructions

DIVAR IP U DIP N, DIP HD, DIP HD. en Installation Manual

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

StorTrends 3400 Hardware Guide for Onsite Support

DVI DA2 and DVI DA 4 User Guide

esata External Storage

SUPER USER S MANUAL. SC829 CHASSIS Series SC829TQ-R920UB 1.0

About the BitStorm 6051 POTS Splitter

Co-location Interconnect Power Panel (CIPP) Installation Guide

HP 16/18-Port Cable Management Kit Installation Guide

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Installation Instructions For Slider Casement Air Conditioners

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

SUPER USER S MANUAL. SC815 Chassis Series SC815S-560C(V)(B) SC815S-700C(V)(B) 1.1a SC815TQ-710U(B) SC815TQ-560U(V)(B) REAR VIEW FRONT VIEW

Ceiling Fan Installation Instructions

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

Access Server Rack Cabinet Compatibility Guide

NetCom Quick Setup Guide

Small form factor bay converter and hard drive installation

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

SUPER USER S MANUAL. SC808 Chassis Series SC808T-1200W. 1.0b

IP DSLAM IDL Quick Installation Guide

Installing your upgrade processor

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

HP Port Switches Quick Setup Guide

Uninterruptible Power Supply. 500 kva kva

Hardware Manual. Versio. 2 RU Platform 7/10/

Raritan LCD KVM Console (T1700/T1900)

Cabinets 101: Configuring A Network Or Server Cabinet

Parallel Redundant Uninterruptible Power Supply

Raritan LCD KVM Console (T1700/T1900)

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

SuperLoader 3. Quick Start Guide. Installing the Autoloader 0

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

How To Test A Power Distribution Unit

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

How to Set Up Your NSM4000 Appliance

DCF Optimized Rack System

What is the Fan Tray Assembly?

RACKMOUNT SOLUTIONS. 1/7/2013 AcoustiQuiet /UCoustic User Guide. The AcoustiQuiet /UCoustic User Guide provides useful

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

VX 2400 Dimmer User's Manual

Installation Instructions

MGB Chrome Bumper Conversion

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

The SYSTIMAX ipatch System

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Hard Disk Drive (HDD)

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

Cisco TelePresence MCU 4500 Series safety and compliance information

Threat Analysis Reporter QUICK START GUIDE. Model: TAR TAR S (5K02-62), TAR H (5K02-66), TAR MSA (5K02-67) Release: / Updated:

NuMount VESA Adapter for imac ASSEMBLY MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

UPGRADING AND SERVICING GUIDE

SUPER USER S MANUAL. SC809 Chassis Series SC809LT-780B SC809T-780B SC809T-980B SC809T-1200B. 1.0b

INSTRUCTIONS: LocknCharge Laptop Carts

Serial ATA to Serial ATA

SUPER USER S MANUAL. SC825M Chassis Series SC825MTQ-R700LPB SC825MS-R700LPB SC825MTQ-R700UB. 1.0a

Transcription:

This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure may differ slightly from that presented in this document. Please also refer to the installation instructions that came with the rack unit you are using. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows any damage you should file a damage claim with the carrier who delivered your Barracuda. Decide on a suitable location for the rack unit that will hold your chassis. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need to place it near a grounded power outlet. Be sure to read the Rack and Server Precautions below. The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow. Choosing a Setup Location Leave enough clearance in front of the rack to enable opening the front door completely (~25 inches). Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and other secure, ventilated environments). Please take the following precautions when installing the rack: Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. In a single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together. Always make sure the rack is stable before extending a component from the rack. You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable. General Server Precautions Review the electrical and general safety precautions that came with the components you are adding to the chassis. Determine the placement of each component in the rack before you install the rails. Install the heaviest server components on the bottom of the rack first, and then work up. Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure. Allow the hot plug Copyright 2004-2009, Barracuda Networks Inc. Page 1 of 6

hard drives and power supply modules to cool before touching them. Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature (Tmra). Proper Airflow and Mechanical Loading Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised and to prevent any hazardous condition that could arise due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing these concerns. Reliable Ground To ensure a reliable ground at all times, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). Rack Mounting Instructions This section provides information on installing the SC825 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure may differ slightly from that presented here. You should also refer to the installation instructions that came with the rack unit you are using. NOTE: This rail will fit a rack between 26" and 33.5" deep. Copyright 2004-2009, Barracuda Networks Inc. Page 2 of 6

Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Figure 1. Identifying the Sections of the Rack Locking Tabs Both chassis rails have a locking tab. The tabs lock the server into place when it is installed and pushed fully into the rack. These tabs also lock the server into place when fully extended from the rack so as to prevent the server from coming completely out of the rack when you pull it out for servicing. Copyright 2004-2009, Barracuda Networks Inc. Page 3 of 6

Figure 2. Identifying the Sections of the Rack Rails (right side rail shown) Installing the Inner Rail Extension The SC825 chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use a server rack. Attach the inner rail extension to stabilize the chassis within the rack. To install the inner rails: 1. Place the inner rack extensions on the side of the chassis, aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the pre-attached inner rail. 2. Slide the extension toward the front of the chassis. 3. Secure the chassis with 2 screws as illustrated above. Repeat steps for the other inner rail extension. Copyright 2004-2009, Barracuda Networks Inc. Page 4 of 6

Outer Rack Rails Outer rails attach to the server rack and hold the server in place. The outer rails for the SC836 chassis extend between 30 inches and 33 inches. Figure 3: Assembling the Outer Rails Installing the outer rails to the rack: 1. Attach the short bracket to the outside of the long bracket. You must align the pins with the slides. Also, both bracket ends must face the same direction. 2. Adjust both the short and long brackets to the proper distance so that the rail fits snugly into the rack. 3. Secure the long bracket to the front side of the outer rail with two M5 screws and the short bracket to the rear side of the outer rail with three M5 screws. 4. Repeat steps 1-4 for the left outer rail. C B Figure 6-4: Installing the Rack Rails Copyright 2004-2009, Barracuda Networks Inc. Page 5 of 6

Installing the chassis into a rack: 1. Confirm that the chassis includes the inner rails (A) and rail extensions (B). Also confirm that the outer rails (C) are installed on the rack. 2. Align chassis rails (A and B) with the front of the rack rails (C). 3. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs "click". 4. (Optional) Insert and tighten the thumbscrews that hold the front of the server to the rack. Figure 5. Fully installed SC825 Chassis Copyright 2004-2009, Barracuda Networks Inc. Page 6 of 6