Model RI ICE Pack Impressed Current Electronic Package the remedy for Mag headaches Typical Applications:



Similar documents
Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

TROUBLESHOOTING PRELIMINARY

CATHODIC PROTECTION SYSTEM DESIGN

Magnesium TM. Soil Anodes. High Potential Magnesium. Production - Quality Control. Laboratory- Testing. Packaging- Availability

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

reduction ore = metal oxides metal oxidation

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Operating Instructions

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

Corrosion Control & Cathodic Protection for Water & Wastewater Systems

Experiment NO.3 Series and parallel connection

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Line Loss WSDOT Winter 2008 BZA

STREETLIGHT SYSTEM GROUNDING AND BONDING

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Telecommunication Line Protectors

Air-cooled Generator Battery Charger Installation Guidelines

How To Wire Wire Wire For A Decoder System

ECEN 1400, Introduction to Analog and Digital Electronics

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Video Camera Installation Guide

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Buck - Boost Transformers

AC and DC Drive System Installation Information

Underground Storage Tanks

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

How To Get A Power Line Extension

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

TABLE OF CONTENT

Time Propane Pressure Drop Test Sign-Off Sheet

1. The diagram below represents magnetic lines of force within a region of space.

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

PXL-250: Network Wiring

IRRIGATION PUMPING Table of Contents - Section 900

Voltage Drop (Single-Phase)

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

RX-AM4SF Receiver. Pin-out. Connections

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Modified True/False Indicate whether the statement is true or false. If false, change the identified word or phrase to make the statement true.

What is a multimeter?

LOXONE 12 Channel Amplifier

C106 Series. Sensitive Gate Silicon Controlled Rectifiers

Building the HVPS High Voltage Power Supply

Current Probes. User Manual

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Table of Contents. TransformerIQ FAQs 1

rpsa FIRE PROTECTION ENGINEERS

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

Type SA-1 Generator Differential Relay

No Phone Line II-48 System

Application/Connection Examples

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

How To Use A Cdm250 Digital Multimeter

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Self Monitoring Power Supply (BPSM)

GUIDELINES FOR THE EVALUATION OF UNDERGROUND STORAGE TANK CATHODIC PROTECTION SYSTEMS

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Three-Phase Electric Power Distribution for Computer Data Centers

Hyperlinks are Inactive

Features. Picture. Specifications

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Operating Instructions

The electrical energy produced at the gen

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Voltage Loss Formula s

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

The Electrical Control of Chemical Reactions E3-1

CITY OF LOS ANGELES CALIFORNIA

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Intersection Preassembled 19-inch Rack

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Copper wire figures. AWG Table

Telemetry system for cathodic protection equipment of underground metal pipelines

400 Series - Mini USB Buccaneer

AN INTRODUCTION TO MAGNETIC AND UTILITY LOCATING BASICS

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Inverter / Charger Installation General Operations and AC and DC Connections

Welcome to Linear Controls Quarterly Training

Solid State Timers Type F

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Voltage Drop. Voltage Drop 1

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Model 201 Wiegand Touchpad Reader Installation Guide

Multi-Function Ground

GALVANIC CATHODIC PROTECTION 1.0 CONTENTS. 1.1 Aluminium Anodes. 1.2 Zinc Anodes. 1.3 Magnesium Anodes SECTION

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Grounding & Bonding Why it is done And How to Install Properly

Power Supplies. 1.0 Power Supply Basics. Module

Transcription:

Model RI ICE Pack Impressed Current Electronic Package the remedy for Mag headaches Typical Applications: Replaces Mg anodes for cathodic protection of underground structures Useful for spot protection in areas not adequately covered by primary system Featuring: Constant current output does not vary with seasonal variations in resistivity 20 year design life with proven high silicon iron anodes Direct hook-up to 115 VAC 120 or 240 milliampere output currents Other sizes available on special order Packaging 3 inches (8 cm) dia cotton bag, 20 inches (50 cm) long Design Compatibility The Model RI ICE Pack TM is a self-contained unit consisting of a constant current rectifier connected to a high silicon iron anode and packaged in a cotton bag containing calcined petroleum coke. The rectifier circuit is available in both half wave and full wave models. Half wave rectifiers are used for a structure electrically bonded to the power company grounding system; full wave units are used when the structure is electrically isolated from the grounding system. This unique circuit does not generate heat; therefore, it is completely encapsulated in potting compound to protect it from the environment. Each ICE Pack TM can replace several magnesium anodes; and with a design life of 20 years, it also eliminates one anode replacement cycle. ICE Packs TM are a cost effective alternative for cathodically protecting any underground structure. electrochemical devices, inc. Sales office: P.O. Box 355; Belmont, MA 02478-0003 Tel: 617-484-9085 Fax: 617-484-3923 Main office: P.O. Box 31; Albion, RI 02802-0031 Tel: 401-333-6112 Fax: 401-333-9724 R Series Rectifiers RI4.doc-03/05 EDI 2005

Will the ICE-Pack TM Cure Your Mag Headaches? If you can answer YES to any of the following questions... Is the soil resistivity above 1000 W-cm? With magnesium anodes, output drops with increased soil resistivity. Typically, a 17 lb. mag anode will put out up to 100 ma in 1000 Ω-cm soil. With higher soil resistivities additional mags are needed to maintain the required current output. However, with an ICE-Pack, a coke column can be designed to lower ground bed resistance, which provides you with the required current output. For example, if the soil resistivity is 25,000 Ω-cm, an ICE-Pack will produce 120 ma of current in a 7.5 ft. column of coke; and for soil resistivities of 5000 Ω-cm and lower, no additional coke is necessary! Have interference problems prevented you from installing a conventional impressed current system? Each ICE-Pack will put out the same current as 1-2 magnesium anodes. Like a mag, it can be installed close to the structure so that the current output from the anode is less likely to be shielded by foreign structures. Is 115 VAC power conveniently available? The ICE-Pack is designed to operate with 115 VAC input. Up to twenty-five 125 ma ICE-Packs can be spliced onto a #12 AWG header cable which is terminated in a standard safety disconnect box. An ammeter or shunt, if required, can be installed in the box. Are your installation costs increasing every time you replace a mag? The ICE-Pack has a 20-year design life. A magnesium anode typically lasts 8-10 years. Each ICE- Pack eliminates at least one replacement cost and may save as many as two. The initial installation costs for either anode are about the same.... an ICE-Pack will solve your anode problems.

Performance Characteristics Data shown are for the half wave circuit; full wave circuits will be similar. Output Current, ma DC Output Current The 120mA and 240mA models will maintain rated output in groundbeds up to about 50 ohms. 300 250 200 150 100 50 0 0.1 1 10 100 Resistance, ohms Anode Voltage Anode voltage adjusts automatically to keep current at the rated level. To prevent a reduction in current output in high resistivity soil, the groundbed resistance can be reduced by increasing the length of the coke column. 120mA 240mA Output Voltage, V DC 100 10 1 0.1 0.1 1 10 100 Resistance, ohms

120 & 240 ma sizes cotton bag steel canister #14 AWG UF cable 500, 750 & 1000 ma sizes L = 54 inches on 500 ma unit L = 84 inches on 750 & 1,000 ma units Specify as EDI Model RI-xxy-LWnnn where xx = rectifier size code y = wave form code nnn = lead wire length, feet Size codes, xx 12 = 120 ma 24 = 240 ma 50 = 500 ma 75 = 750 ma 1k = 1,000 ma Wave form codes, y H = half wave F = full wave Other size rectifiers are available on special order. 23" (nom.) 3 1/2" (nom.) L" (nom.) 8" (nom.) Constant current rectifier and high silicon iron anode are contained in a cotton bag or steel canister. Backfill is coke breeze. EDI, electrochemical devices, inc. PO Box 31, Albion, RI 02802 401-333-6112 TM ICE Pack Rectifier - Anode Ass'y DRAWING SCALE VARIES DATE 04/14/03 DRAWN BY FJA NUMBER RIASY 2003

AC ground AC neutral (white) AC hot (black) (See Note) Line fuse (typ.) Load AC safety ground lug copper wire from ground rod (if required by local code authorities) white wire from rectifier black wire from rectifier terminal block #12 wire from structure bare wire from rectifier Alternate wiring diagram for permanently installing ammeter or shunt. ammeter or shunt Note: It is recommended that a surge protector be installed on the AC power line to the rectifier. SCALE DRAWN BY DATE DRAWING NO. HALF FJA 03/24/05 RIAPP1 electrochemical devices, inc. PO Box 31, Albion, RI 02802 401-333-6112 Model RI Wiring Diagram C EDI, 2005

ground rod 115 VAC meter (if req'd) fused disconnect #12 structure lead underground splice Model RI ICE Pack (typ) TM 120 ma constant current rectifier high silicon iron anode 3 1/2" Ø x 17" cotton bag filled with calcined petroleum coke header cable #12 Type UF 2 conductor with ground lead wire #14 Type UF 2 conductor with ground Up to 25 125mA ICE Packs can be installed on a single header cable structure C EDI, 2003 TM RIDS1