AN INTRODUCTION TO MAGNETIC AND UTILITY LOCATING BASICS
|
|
|
- Pauline Hunt
- 10 years ago
- Views:
Transcription
1 AN INTRODUCTION TO MAGNETIC AND UTILITY LOCATING BASICS
2 TABLE OF CONTENTS AN INTRODUCTION TO PIPE AND CABLE LOCATING BASICS how to apply signal power levels conductive mode inductive mode inductive clamp mode passive power trace mode adjusting gain how to sweep how to trace measurement test mode milliamp display Chapter 1: LOCATING POWER CABLE applying signal conductive mode signal to transformer signal to meter signal to targeted cable inductive mode inductive clamp mode signal to primary cables signal to secondary cables slack loops open ends streetlight cables Chapter 2: LOCATING PIPE applying signal inductive mode conductive mode tracer wires inductive clamp mode open ends locating fiber optic starting from an office splice points tracing fiber Chapter 4: LOCATING CATV CABLE applying signal inductive mode conductive mode inductive clamp mode slack loops in cable starting from pedestals Chapter 5: SONDE LOCATING theory how to search measuring depth pipe diameter limitations specifications & dimensions maintenance Chapter 6: MAGNETIC LOCATING theory how to search how to pinpoint sensitivity adjustment strongly magnetized markers chain link fences metallic pipe location cluttered areas things to remember Chapter 3: LOCATING TELEPHONE CABLE introduction applying signal inductive mode conductive mode inductive clamp mode slack loops and butt splices unknown laterals starting from pedestals service drops i
3 AN INTRODUCTION TO PIPE AND CABLE LOCATING BASICS How to apply signal: Locating pipes and cables with utility locators is usually a matter of applying a signal to the utility with a transmitter and then detecting that signal with the receiver. Signal can be applied to utilities in three basic ways: conductive mode: Using the direct connect cable and supplied clips. inductive mode: By sitting the inductive antenna / transmitter over the intended conductor. inductive clamp mode: Uses a Coupler/Clamp. Regardless of the method used, the key to getting a strong signal is applying the proper frequency. All signals applied to buried lines dissipate into the ground, which means that the signal gets weaker as it gets farther away from the transmitter. The main factors that affect signal strength are cable diameter, soil conditions, signal frequency and transmitter power level (watts), and of these signal frequency and power level setting are under control of the operator. Frequencies are grouped into four classes: Low - less than 1 khz: Since low frequencies don t propagate to other lines readily, they are a good choice for congested areas with several overlapping utilities, and they are also good for tracing over long distances. But low frequencies can t be used with inductive or inductive clamp methods - only the conductive method works. Medium - between 1 and 10 khz: Medium frequencies are the most generally useful frequencies for location. Most can be applied with conductive and inductive clamp methods. They will occasionally propagate to other lines, but not so readily as higher frequencies. They don t travel as far as low frequencies, but are still useful for traces of up to a mile. Some small diameter lines, like telecom cables, may require higher frequencies for a good signal. High - between 10 and 100 khz: High frequencies weaken rapidly compared to lower frequencies, and they readily propagate to nearby conductors. But they re useful for small diameter cable TV and telecommunication lines. They are best applied by the inductive and inductive clamp methods. If the signal is weak near the beginning of the trace, try a higher frequency. Very High - greater than 100 khz: Because they attenuate very quickly compared to lower frequencies, and because they easily propagate to other conductors, Very High frequencies are a good way to rapidly sweep for all utilities in a congested area. Very High frequencies will also give good signal across gaps in a line, such as insulated pipe joints or cable breaks. Power levels: Power levels are regulated by FCC requirements for specific frequency ranges. For TraceMaster products they are as follows: 1
4 1 Watt - Available at 82 khz 2 Watts - Available at 575 Hz and 8 khz 5 Watts - Available at 575 Hz and 8 khz High watts are beneficial to achieve long distances on small conductors such as electrical, telecommunication cables and tracer wires. It is also beneficial to push through high resistance conductors or jump across non-conductive joints, such as ductile iron pipes. High watts will propagate its energy to nearby or adjacent buried utilities. Choose a lower watt to minimize propagation. SIGNAL APPLICATION METHODS: Conductive: The conductive method means that a direct connection is made to the pipe or cable being located - this isolates the signal to just one line. For a strong signal over a long distance, and for minimal coupling to other conductors, low frequencies are best. Proper grounding is important when using the conductive method: in general, the better the ground, the stronger the signal. The transmitter is electrically connected at one end and the signal travels along the desired line, goes to ground, and completes the circuit via the ground stake. A poor connection or ground will give a weak or non-existent signal. The ground stake should be as far from the far end ground as possible, and should also be well away from the black clip red clip ground stake This angle between the ground wire and the suspected cable path should always be as close to 90º as possible. underground line trace path. In practice, this means that extending the stake away from the probable trace path at 90º is usually the best option (see illustration). If necessary, ground leads can be extended with any insulated wire, and ground stakes can be reset after the actual trace path is discovered. 2
5 Inductive: Of the three signal application methods, the inductive method is the simplest, provided that at least one point on the trace path is known. Just place the transmitter on the ground directly over the buried pipe or cable, and line up the transmitter arrow parallel to the line direction. If the transmitter is not within five feet or so of the line, signal is likely to be very weak. The inductive method tends not to work in situations where several conductors overlap, where the conductor being traced is not well grounded at both ends, or where the conductor is very deep. High frequencies should be used, from 33 khz to 82 khz, but keep in mind that the likelihood of other conductors picking up signal increases as the frequency is raised. Also, if the receiver is within 40 feet of the transmitter, it will pick up signal through the air so it is best to begin at least 40 feet away from the transmitter when tracing. underground cable Align the arrow on the transmitter case with the suspected underground line, and place the transmitter directly over the line. Inductive Coupler / Clamp: The third way to apply signal is with the inductive clamp method. By closing the clamp s jaws around a pipe or cable, a signal can be induced into a particular line, reducing the chance of other conductors picking up signal. The clamp must close fully, and the conductor must be well grounded on the near and as well as the far end. This method varies in specific applications, as described elsewhere in this manual. ground point, signal ends inductive clamp ground point, signal ends Direction of current; current travels away from clamp and ends at ground points. underground line 3
6 Passive Power Frequencies: In Passive mode, the transmitter is not used. Instead, the receiver is used to search for 50 or 60 Hz signals, like those produced by energized cable carrying AC power. These are low frequencies, but they can still propagate to other nearby conductors. In passive mode, it is not possible to distinguish between conductors - the signal could be coming from any grounded conductor, such as buried pipe or rebar. But knowing they exist can be useful. Energized power cables are easy to detect except for those that have been designed so that the out and return fields cancel each other, as is typically the case with appliance power cords. Cables like this, particularly three-phase cables, are hard to detect. One trick that can help when tracing 60 Hz three-phase cables is to use the reinforcing ninth harmonic of 60 Hz, 540 Hz. Similarly, 50 Hz three phase cables can be detected at the 11th harmonic, 550 Hz, which your receiver is factory set to detect. Trace Mode: Several indicators help you to zero in on pipe or cable location. The receiver tone changes pitch and is highest when directly over the traced utility. Similarly, numeric strength indicators are also at maximum directly over lines. Both these indicators rely on the receiver handle being in alignment with the cable path. If the path changes direction abruptly, display arrows can guide you back to the true path, as shown in the illustration. If no arrow elements display, then signal strength is too weak for detection and you will have to search using the receiver tone and numeric indicators - you may also have to try twisting the receiver to align the handle with the cable path. Left Arrow: Move receiver to the left to get back on trace path. Right Arrow: Move receiver to the right to get back on trace path. Both Arrows & Bar: This signal, together with a beeping sound, indicates you are directly over trace path. Adjusting the Gain: The gain setting determines how sensitive the receiver is to a signal, and is therefore an important adjustment. If the gain is set too low no signal will be detected and if it s set too high accuracy is reduced and tracing the wrong conductor is likely. Gain can be set manually or automatically. To set gain automatically, just turn the control clockwise until it clicks, or in the case of the XTpc by not pushing the up and down arrows - the XTpc is in the automatic gain mode when turned on. To set manually, turn the control up or down as needed, but with the TraceMaster don t turn so far counter-clockwise that it clicks. Set the gain with the receiver directly over the targeted line. You can use the gain control s numeric strength indicator as a guide. As a rule of thumb, the gain should be set to the lowest setting that still shows a clear peak over the trace path. The signal strength should not approach 4
7 999 for XTpc models or 99 for TraceMaster models, as this is usually too high. Good gain setting usually yields signal strength between 200 and 800 (or 20 and 80 for TraceMaster models). As you move away from the transmitter, signal strength drops and you will have to adjust gain periodically. Sweeping: Sometimes you will want to locate all conductors in a given area, rather than tracing an individual line. This is done by sweeping. Use the inductive method to apply the highest frequency available - all underground conductors will carry signal. Walk in a grid pattern as shown in the illustration, sweeping in two perpendicular directions. When you get a response, stop sweeping, move the transmitter to that point and trace the conductor you ve found out of the area of interest, marking as you go. Then return to your starting point and resume sweeping, looking for more conductors to trace. When finished sweeping using the inductive method, sweep again using passive power mode. This technique will reveal all grounded metal pipes and cables, and non-conducting lines with properly installed tracer wires. Tracing: To trace an individual pipe or cable, it s best to apply signal to the targeted line with the conductive method or the inductive clamp method. If this isn t possible, you can still use the inductive method but other conductors are more likely to pick up a signal. Move slowly while tracing the cable, moving the receiver side to side over the trace path. Pay attention to handle alignment. Mark the path as you go, and, if in manual gain mode, remember to adjust gain periodically as you move away from the transmitter and signal strength declines. Measurement Test Mode (For TX5 Transmitter models only): When using the conductive method, the LCD display on the transmitter provides initial measurement indicators for voltages sensed in AC and DC values and total resistance values. This information will alert the operator of the presence of Live or energized voltages on the conductor. It is not advisable to continue locating in conductive method if power (voltage) is not removed. The measured resistance provides a perspective of the conductors integrity and also the condition of the grounding. Resistance values are provided in a range from a few ohms to a few meg ohms. Values closer to the ohm range indicate a good ground and good continuity between conductor, earth ground and the transmitter. A resistance value near the meg ohm range reflects poor continuity or ground, and will adversely affect the quality of the locate. In these cases a higher frequency or higher power level (watts) may be required. 5
8 Milliamp Display of Signal Strength: In addition to the red and green indicators of signal strength described in following chapters, the new generation of Schonstedt XTpc and TraceMaster pipe and cable locators will display the strength of signal in milliamps. On the XTpc, this is as simple as turning ON the transmitter: milliamps are noted on the transmitter LCD display. On the TraceMaster, you must press the show status button on the transmitter. After a short delay, no more than ten seconds, the milliamp reading will flash on the receiver LCD. On TraceMaster models with a TX5 transmitter the LCD display provides an indication of the milliamp value. The value will alternate with the displayed frequency selected. For both receivers, this feature applies to the conductive mode only. A reading of 30 to 40 milliamps generally indicates a good signal, a lower reading indicates a weaker signal. 6
9 1 LOCATING POWER CABLE (Note: See Introduction for an explanation of 60 Hz locating) Applying Signal to Power Cables - Conductive Method: You can apply signal directly with the conductive clip in several different places, including the transformer, meter, and the targeted cable. Transformer: If you don t need to isolate a particular cable, you can apply signal to all the neutral (primary and secondary) grounded at a particular transformer by simply connecting the transmitter to the transformer cabinet. You don t need to cut power to any lines or even open the cabinet. red clip to transformer ground stake and black clip 7
10 Meter: The secondary neutral is grounded at both the transformer and the meter, so secondary cables can be traced by connecting the transmitter directly to the meter s metal box. Since, typically, the transformer is better grounded than the meter, you are likely to get a better signal when connecting to the meter. Remember to place the transmitter s ground stake well away from the meter - you may have to extend it with insulated wire. This is a fast, convenient signal application technique, as you don t have to break the meter seal. Use the lowest frequency available, usually 575 Hz, in order to minimize the propagation of signal to other lines in the area. Ground stake and black clip: place as far away from meter as possible red clip Targeted Cable: If power has been cut to a cable, and the far end is grounded, you can attach the conductive clip directly to the targeted cable, thus isolating the cable. See illustration below. red clip far end ground Ground stake and black clip: place as far away from meter as possible, at right angles to cable path. 8
11 Applying Signal to Power Cables - Inductive Method: The inductive method can be used on primary and secondary cables. The best way to trace a particular cable with the inductive technique is to set the transmitter down over the cable and set it to the 82 khz frequency, or 33 khz frequency if you are using the XTpc-33 khz locator. Then move out at least 50 feet away from the transmitter and find a clear peak and mark it. Set the transmitter at this point and work back to the original location, confirming that you are on the correct trace path. Leapfrogging the transmitter like this is also a good way to trace cables that conduct poorly and give a weak signal. If the signal is very weak, try a higher frequency. 1st position about 50 feet 2nd position Applying Signal to Power Cables - Inductive Clamp Method: Only use the inductive clamp to apply signal to the neutral of primary energized cables - never to the primary cable itself. A circuit path for the signal is formed by the neutral and its grounds. Using the inductive clamp to apply signal to the neutral between grounds will give three-phase primary elbows readings all along the section between the grounds. Of course, the clamp jaws must always be fully closed around the cable. You should start with a frequency of 82 khz or, if you are using the XTpc- 33 khz locator, 33 khz. Try higher frequencies if inductive clamp needed. If you are locating a three-phase primary cable, you should find a spot on all the concentric neutral as close as possible to the earth ground and connect the clamp there; the earth ground signal will be applied equally to all the cables. See illustration. 9
12 Never place the clamp around an individual primary cable; this is dangerous and inefficient. Since cables are close to each other, in the same trench, the signal will cancel itself as it travels in opposite directions along cables. If you are locating single-phase primary cable in a loop configuration, you don t have to worry about canceling. Use the inductive clamp to apply to the targeted cable s individual concentric neutral. See illustration. single-phase primary elbows inductive clamp earth ground Applying Signal to Secondary Cables: When locating secondary cables, the meter box is the most convenient place to access the neutral. There are several ways to apply signal. Sometimes the riser pipe is nonmetallic, usually PVC - if this is the case, you can put the clamp right around the riser. If the riser is metallic, or if you can t fit the clamp around it for some reason, you can break the meter s seal and clamp around the neutral inside the box as shown. neutral conductor The meter box might ground via an external wire that goes to an earth ground. If so, you can clamp around this external ground, since it is connected to the neutral inside the box. Other utilities might also be using this ground wire, and you must place the clamp above them to avoid applying signal to them as well. ground wire CATV Phone ground rod 10
13 Identifying Slack Loops: While tracing, you may notice an abrupt weakening of signal strength. If the signal just as abruptly returns to at or near the same strength, you may have come across a slack loop as illustrated below. To verify this, mark the spot and then back up a few feet. Trace the path again, but this time hold the receiver handle perpendicular to the trace path. The signal will be much weaker, but may return to full strength at the marked point and then quickly decline again - the reverse of the previous pattern. If this is the case, you have probably found a slack loop. marked spot Retrace path with receiver handle held perpendicular to path. slack loop Identifying a Cable Open End: Power cables are occasionally left with open ends, either because they have been severed, or buried in anticipation of future use. If the cable end doesn t ground due to insulation, try this technique: Assuming the cable is grounded at the access point, use the inductive clamp method to apply signal. Alternately, where the access end is not grounded, use the conductive method. In either case you should use the highest frequency available. Now trace the cable normally - signal will abruptly stop at the open end. Locating Buried Streetlight Cables: Power lines for streetlights present special challenges. They are often powered off during the day, and since the supply is a transformer they can appear to be ungrounded when the power is off. Locating by means of passive power frequencies, 50 or 60 Hz, will not work. Try using the inductive clamp, connecting at the base of the light as shown and using the highest frequency available. Be cautious and check all nearby lights before digging. 11
14 2 LOCATING PIPE Applying Signal to Pipe with the Inductive Method: The best way to trace a pipe with the inductive technique is to set the transmitter down over the presumed pipe path and set it to the 82 khz frequency. The arrow on the case should be aligned with the path. Then move out at least 50 feet away from the transmitter and find a clear peak and mark it. Set the transmitter at this point and work back to the original location, confirming that you are on the correct trace path. Leapfrogging the transmitter like this is also a good way to trace pipes that conduct poorly and give a weak signal, and you can extend range or get past insulated pipe joints by moving the transmitter ahead as needed. If the signal is very weak at 82 khz, try a higher frequency (available only with TraceMaster models with 455 khz). Unfortunately, the XTpc-33 khz locator will not work well for locating pipe, as 33 khz is usually too low of a frequency to give a good signal on steel or ductile iron pipe. 1st position 2nd position about 50 feet Applying Signal to Pipe with the Conductive Method: The conductive method is a good way to apply signal to metal pipe. You can attach the clip at a valve or meter, or directly to the pipe itself. Ground the transmitter as described in Chapter One, then insert the conductive cable into the transmitter jack. To create a circuit, apply a ground at the far end of your locating area using, for example, a length of wire and a screwdriver; this will confine signal to the length of pipe between the transmitter ground and the far end ground. But be aware, some pipes are connected with non-conducting gaskets or joints, which will severely limit the length of your trace. 13
15 If you can t find a place to apply a far end ground, the conductive method will still work, but signal will travel both directions from the transmitter, and response will rapidly decrease as you move away from the transmitter. The rate of decrease is affected by the pipe diameter and the frequency and power level (watts) you choose. One general principle that increases the length of trace is to use low frequencies/high power with large diameter pipe and high frequencies/low power with smaller pipe. In all cases, use the lowest frequency and lowest power level that gives adequate response. Ground stake and black clip: place as far away from meter as possible at 90º red clip on valve Ground far end with any wire and, for example, screw driver near end buried pipe far end Ground stake and black clip: place as far away from meter as possible at 90º red clip on valve signal signal leaking signal 14
16 Conductive Method on Tracer Wires: Sometimes non-metallic pipe, such as PVC or HDPE, is equipped with tracer wires that run the length of the installed pipe. This is easy to trace by attaching the conductive clip to the wire, setting the ground as described in Chapter One, and plugging into the transmitter jack. As with metallic pipe, it is best to apply a ground at the far end of the tracer wire; this allows use of a low frequency that will give signal over a long distance. If applying a far end ground is not possible, use a higher frequency. In some cases, the tracer wire on a service line or lateral is not electrically connected to tracer wire on the main line - the idea is to limit signal to one of the lines at a time. If the transmitter is not too far away from the main line connection, it is worth trying a high frequency or higher power level; in some cases signal may transfer to the main line wire and allow tracing. non-metallic service service tracer wire non-metallic service twisted non-electrical connection far end ground main tracer wire electrical connection Applying Signal to Pipe with the Inductive Clamp Method: The inductive clamp method is an excellent way to locate underground metallic pipe, and can often be applied by digging and exposing enough of the pipe to allow placement of the clamp. Used by itself, without a ground, signal will travel both directions from the clamp, and response will decrease rapidly. You can confine signal to signal 15
17 one direction by attaching a ground - using, for example, the ground stake and a length of insulated wire - on the opposite side of the inductive clamp. This will increase the signal significantly. signal signal One special case occurs when you use the inductive clamp method on a gas meter s metallic service pipe; in this case, always apply a ground to the pipe above the clamp and below the insulating coupling, as shown, to create a good return signal. Without such a ground, the valve s insulating coupling will block the return signal and severely decrease the signal. ground below insulating coupling and above inductive clamp meter 16
18 3 LOCATING TELEPHONE CABLE Introduction: Review the Introduction of this manual for general information on signal application techniques and locating. This chapter looks at techniques used specifically for telephone cable locating. Applying Signal to Telephone Cables: Inductive Method: The inductive technique is convenient because no access to the cable is needed - just set the transmitter on the ground directly over the cable and line up the transmitter arrow parallel with the suspected cable path. But the inductive technique also tends to apply signal indiscriminately to all nearby conductors, and is a poor choice when attempting to trace a particular cable. The best way to trace a particular cable with the inductive technique is to set the transmitter down over the cable and set it to the 82 khz or 33 khz frequency. Then move out at least 50 feet away from the transmitter and find a clear peak and mark it. Set the transmitter at this point and work back to the original location, confirming that you are on the correct trace path. Underground cable; transmitter should be placed directly over cable with arrow on case lined up with cable path. If transmitter is more than a couple of feet away from cable path, signal will be very weak. 17
19 Leap-frogging the transmitter like this is also a good way to trace cables that conduct poorly and give a weak signal. If the signal is very weak at 82 khz and you are using a TraceMaster multiple frequency locator, try the 455 khz frequency (455 khz is not available in the Tx5 transmitter). Conductive Method: The conductive method is a good way to trace a particular cable, as signal can be applied directly to the targeted cable and the cable can be traced for long distances - up to a mile. Be sure the connection between the transmitter clip and the conductive portion of the cable is clean and secure, without any rust, dirt or paint. Using the 575 Hz frequency on the TraceMaster is a good way to confine the signal to the targeted cable, but keep in mind that the signal will not travel beyond a break. In TraceMaster models with a Tx5 transmitter, selecting a higher power level will push the signal beyond the cable break. To make the connection to the telephone cable you need access to the cable shield. Connect the red transmitter clip to the cable by disconnecting the shield bond at the near end, but do not disconnect the far end shield bond as it provides a good ground for the cable s far end. A good ground is also needed, as explained in the first section of this manual; don t ground to water pipes or other conductors as the return signal can complicate locating. black clip and ground stake red clip Do not remove this bond (ground) Remove this bond (ground) Turn the transmitter on, using the lowest frequency that gives a clear signal. On the TraceMaster transmitter (not available on the Tx5 transmitter) circuit quality is indicated by the OUTPUT POWER LED. If the LED is green, impedance is below 2 k ohms, indicating a good circuit. If the LED alternates between green and red, impedance is probably between 2 and 4 k ohms, indicating an adequate circuit. If the LED is continuously red, the impedance is higher than 4 k ohms. 18
20 If the LED is red, or alternating red and green, try to improve the circuit. Check that the connection to the cable is tight and clean, check all cables, check the ground, etc. But fairly often the circuit is as good as it s going to get. You can still locate with a poor circuit, but you ll probably have to increase receiver gain and you may not be able to trace for as long a distance as you could with a better circuit. For TraceMaster with Tx5 transmitter there are no RED or GREEN LED indicators. Instead the LCD display will indicate a milliamp value ranging from 0 ma to 200 ma. If the milliamp value is HIGH (above 100 ma), impedance is low, indicating a good circuit. If the milliamp value is MEDIUM (between 20 ma to 100 ma), impedance is slightly higher, indicating an adequate circuit. If milliamps is LOW (between 0 ma and 20 ma), the impedance is high and tracing will be difficult or non-existent. Try to improve the circuit. Check that the connection to the cable is tight and clean, check all cables, check the ground, etc. but at times the conductor may be the cause for the poor circuit. You can still locate with a poor circuit. You will probably need to increase the power level, the frequency, or the receiver gain, and as a result you may not be able to trace for as long a distance as you could with a better circuit. Inductive Clamp Method: The inductive clamp method is a nice compromise between the conductive and inductive methods. You can use the inductive clamp to apply signal to a particular cable without having to disconnect that cable. The clamp plug should be inserted into the transmitter jack BEFORE switching the transmitter on. Also, the clamp must always close fully around the targeted cable. Clamp placement is very important, as described. If you place the clamp around the cable above the ground bonding, the signal will travel to the ground, not to the targeted cable. Therefore, the clamp must be placed between the ground bonding and the cable s point of entry into the ground. Place clip here, between the ground bond and the point of entry into earth. Place clip here, at grounded end of short cable, below the ground bond. Where the cable is short, e.g. a service drop, the clamp should be connected on the grounded end, not the ungrounded end. If you only have access to the ungrounded end, use the ground stake and wire to provide a ground. 19
21 The inductive clamp method is not a good choice for cables with ungrounded shields at both ends. But if the cable is long, you can remove the bonding, apply the clamp, and signal will go both ways. Since there are no grounds, you should use the highest frequency possible. You can still use the inductive clamp method where several cables have a common grounding point. Signal will propagate through all the cables, but the cable you have isolated with the clamp will have the strongest signal. stronger signal weaker signal You can use the inductive method on cables that split at laterals or drop lines. Hook up the clamp and ground as always, and begin tracing. You will notice a drop in signal power when the receiver comes to a junction - this is a good way to find laterals. 50% signal 50% signal 100% signal 20
22 Locating Slack Loops and Butt Splices: While tracing, you may notice an abrupt weakening of signal strength. If the signal stays weaker from that point forward, you have probably found a lateral, as described above. But if the signal just as abruptly returns to at or near the same strength, you may have come across a slack loop or butt splice as illustrated below. To verify this, mark the spot and then back up a few feet. Trace the path again, but this time hold the receiver handle perpendicular to the trace path. The signal will be much weaker, but may return to full strength at the marked point and then quickly decline again - the reverse of the previous pattern. If this is the case, you have probably found a slack loop or butt splice, though you should still check for an unknown lateral, as described below. marked spot slack loop marked spot butt splice retrace path with receiver handle held perpendicular to path 21
23 Locating Unknown Laterals: To check for unknown laterals extending from butt splices or other junctions, return to the points marked in the above procedure. Find a peak signal on the known trace path somewhere between 10 and 25 feet from the mark. Now walk in a circle around the mark, holding the receiver so that it points at the mark - not so that it is aligned with your circular path. The receiver should remain fairly quiet, unless you cross over a lateral. Mark any responses and complete the circle - there may be more than one lateral. Trace these laterals as needed. BEEP! BEEP! feet BEEP! Locating Cables from Pedestals: When starting at a pedestal and tracing a single cable, follow these steps: At the pedestal, use the inductive clamp method to apply signal to the targeted cable. The header in the pedestal may be grounded, but if not, use wire and the ground stake to ground it yourself. Now walk in a circle 10 to 25 feet away from the pedestal, holding the receiver so that it points at the pedestal - not so that it is aligned with your circular path. When you get a response, stop, find the peak, and adjust gain. Make a note of the numeric strength reading. Now continue walking around the pedestal and repeat these steps each time you get a response. When you have completed the circle, the response with the highest strength reading is the targeted cable, and may be traced as needed. 22
24 pedestal feet Locating Service Drops: When tracing service drops, it is usually best to use the house or building as the starting point and apply signal with the conductive method. Then trace as usual. Locating an Open End: Follow these steps to locate a cable with an un-terminated or open end: Where the cable is bonded to ground at the starting point, use the inductive clamp method to apply signal. If the cable is not bonded to ground, use the conductive method. In either case, use the highest frequency possible. Trace as usual; the response will drop off abruptly at the break or open end. Locating Fiber Optic: Can Fiber Optic Cable be Traced? Optical fibers in themselves can t be traced with a utility locator - they are not conductors. But typically one of several types of conductor is included along with the fiber optic cable. This might be a metallic sheath around the fiber, a metallic wire woven into the sheath (for strength and 23
25 locating), or an insulated wire may have been pulled through the same duct as the fiber. If none of these are present, you will have to use site plans or physical location. Underground fiber optic cable is usually installed in a duct, or in a tube run through a large duct. Typically the cable is run from a central office to a remote terminal office, and there may be several splice points along the way, accessed by manholes or hand holes. Where good practices are followed, the metallic sheath or woven wire will be grounded at both ends. But particular grounding policies vary by company, and you should make no automatic assumptions. Sometimes grounding is via remotely actuated relay or voltage transient suppression device. In some cases, fiber optic installations have their own rack-mounted transmitter that can apply signal selectively. If this transmitter applies a 575 or 512 Hz, and your receiver has a 512 Hz mode (the sonde mode) then the cable can be traced using the installation s transmitter and your receiver. Attaching at a Central or Remote Office: If there is no installed transmitter, or if it doesn t match up with your receiver, you can still apply signal at the central or remote office, using your transmitter and the conductive method. To attach the clip, find the ground point for the fiber optic cable s conducting wire - this is usually near the rack mounted digital conversion equipment. Disconnect the wire, then connect your transmitter to it and to the ground point as shown in the illustration. Central Office or Remote Terminal Office conducting wire - attach to red clip conducting wire - ground to rack black clip - ground to rack Put the conductive plug in the transmitter jack, turn on the transmitter, and choose the lowest frequency and highest power level (Tx5 version) available in order to transmit signal as far as possible. 25
26 For TraceMaster models without a Tx5 Transmitter: Circuit quality is indicated by the OUTPUT POWER LED. If the LED is green, impedance is below 2 k ohms, indicating a good circuit. It could be that the circuit is too good - possibly the conducting wire is grounded elsewhere in the office. If you detect no signal outside the office, this may be the reason. If the LED alternates between green and red, impedance is probably between 2 and 4 k ohms, usually indicating an adequate circuit. But it may also indicate an open somewhere between this connection point and the ground at the terminating end or at splice points. If the signal outside the office is present, but weak, this may be the reason. If the LED is continuously red, the impedance is higher than 4 k ohms, usually indicating an open circuit or no ground at the far end. If the LED is red, or alternating red and green, try to improve the circuit. Check that the connection to the cable is tight and clean, check all cables, check the ground, etc. But fairly often the circuit is as good as it s going to get. You can still locate with a poor circuit, but you ll probably have to increase receiver gain and you may not be able to trace for as long a distance as you could with a better circuit. For TraceMaster models WITH a Tx5 Transmitter: Circuit quality is indicated with a milliamp indication. A milliamp indication above 150 ma could indicate the circuit is too good. Possibly the conducting wire is grounded elsewhere in the office. If you detect no signal outside the office this may be the reason. If the milliamp indication is between 20 to 40 ma you have an adequate circuit, but it may also indicate an open somewhere between this connection point and the ground at the terminating end or at splice joints. If the signal outside the office is present, but weak, this may be the reason. If the milliamp indication is near 0 ma (0 to 20 ma) usually this indicated an open circuit or no ground at the far end. Try to improve the circuit by checking that the connection to the cable is tight and clean, check all cables, check the ground, and etc. but fairly often the circuit is as good as it can be. You can still locate with a poor circuit, but you will probably have to increase the power level, frequency, or receiver gain, and you may not be able to trace for as long a distance as you could with a better circuit. Attaching at a Splice Point: If you see that a splice case has one or two metal straps leading to the ground, it s grounded and you can hook your transmitter to it. If there are two straps, odds are that one of them is attached to the metallic sheath or conducting wire on the incoming side and that the other strap is attached to the outgoing side. Alternately, they may be connected inside the case. 26
27 fiber optic cable OUT fiber splices conducting wires IN ground straps ground rod The way to get the strongest possible signal is to disconnect the straps before attaching the transmitter, but local regulations may prohibit this. If the straps can t be disconnected, the signal will split between the ground point and the outgoing and incoming cable, and the tracing range will be reduced. 50% splice point 50% fiber optic cable with conducting wire local earth ground Tracing Fiber Optic Cable: If you are starting from a central or remote office, start outside the building wherever you expect the cable to exit. Search until you get a response. When starting from a manhole or hand hole, circle the hole as described previously, with the receiver pointed toward the hole. When you get a response, find the peak, mark the point and begin tracing. When you trace the cable over a long distance, the signal strength will eventually decrease. This is because the signal bleeds off due to capacitance, or because you pass additional grounds at splice points. Reduction by bleeding off is gradual, and reduction at ground points is abrupt. In either case, try adjusting the gain or increasing the power level (TraceMaster Tx5 models). 27
28 4 LOCATING CATV CABLE Applying Signal to CATV Cables, Inductive Method: The best way to trace a particular cable with the inductive technique is to set the transmitter down over the cable and set it to the 82 khz frequency, or 33 khz frequency if you are using an XTpc-33 Locator. Then move out at least 50 feet away from the transmitter and find a clear peak and mark it. Set the transmitter at this point and work back to the original location, confirming that you are on the correct trace path. Leapfrogging the transmitter like this is also a good way to trace cables that conduct poorly and give a weak signal. If the signal is very weak at 82 khz, try a higher frequency (only on TraceMaster models with 455 khz). about 50 feet 1st position 2nd position Applying Signal to CATV Cables, Conductive Method: To make the connection to the CATV cable you need access to the cable shield. Connect the red transmitter clip to the cable by disconnecting the shield bond at the near end, but do not disconnect the far end shield bond as it provides a good ground for the cable s far end. A good ground is also needed, as explained in the first section of this manual; don t ground to water pipes or other conductors as the return signal can complicate locating. For TraceMasters without Tx5 Transmitter: Turn the transmitter on, using the lowest frequency that gives a clear signal. Circuit quality is indicated by the OUTPUT POWER LED on the TraceMaster. If the LED is green, impedance is below 2 k ohms, indicating a good circuit. If the LED alternates between green and red, impedance is probably between 2 and 4 k ohms, indicating an adequate circuit. If the LED is continuously red, the impedance is higher than 4 k 28
29 black clip and ground stake - keep as far from cable path as possible at 90º red clip on shield connection at premises - do not disconnect or break ground ohms. If the LED is red, or alternating red and green, 7.256"try to improve the circuit. Check that the connection to the cable is tight and clean, check all cables, check the ground, etc. But fairly often the circuit is as good as it s going to get. You can still locate with a poor circuit, but you ll probably have to increase receiver gain and you may not be able to trace for as long a distance as you could with a better circuit. For TraceMaster models WITH a Tx5 Transmitter: A milliamp indication above 100 ma indicates a good circuit. If the milliamp indication is between 20 to 40 ma this reflects an adequate circuit. If the milliamp indication is near 0 ma (0 to 20 ma) usually this indicated an open circuit or no ground at the far end. Try to improve the circuit by checking that the connection to the cable is tight and clean, check all cables, check the ground, and etc. but fairly often the circuit is as good as it can be. You can still locate with a poor circuit, but you will probably have to increase the power level, frequency, or receiver gain, and you may not be able to trace for as long a distance as you could with a better circuit. Applying Signal to CATV Cables, Inductive Clamp Method: Since you don t have to disconnect the cable, the inductive clamp method is usually the easiest way to apply signal to CATV cable. Just place the clamp wherever you have access to the cable, making sure that the jaws are fully closed. Since the cable and its shield grounds, at both ends, form a complete circuit, the inductive clamp applies signal to the entire length of cable between grounds. There will always be a ground on the subscriber s premises, and the other ground may be at a bridging amplifier several blocks away. This can make for a very weak signal. But you can apply a ground yourself, nearer your access point, with the ground stake and a length of insulated wire. This will restrict signal to the 29
30 portion of cable between your ground and the subscriber s ground, thus improving receiver response along that portion. Remember to remove the temporary ground when you are done locating. leave connected to provide ground leave connected to provide ground conductive clamp buried CATV cable signal Locating Cable Slack Loops: While tracing, you may notice an abrupt weakening of signal strength. If the signal stays weaker from that point forward, you have probably found a lateral, as described in previous chapters. But if the signal just as abruptly returns to at or near the same strength, you may have come across a slack loop as illustrated below. To verify this, mark the spot and then back up a few feet. Trace the path again, but this time hold the receiver handle perpendicular to the trace path. The signal will be much weaker, but may return to full strength at the marked point and then quickly decline again - the reverse of the previous pattern. If this is the case, you have probably found a slack loop. marked spot Retrace path with receiver handle held perpendicular to path slack loop 30
31 Locating CATV Cables from Pedestals: When starting at a pedestal and tracing a single cable, follow these steps: At the pedestal, use the inductive clamp method to apply signal to the targeted cable. There may be several cables fanning out from the pedestal, and signal will probably propagate to all of them, even When using the clamp. However, the targeted cable - the one you enclose with the clamp - will have an obviously stronger signal. buried feeder inductive clamp The header in the pedestal may be grounded, but if not, use wire and the ground stake to ground it yourself. This strengthens receiver response by limiting signal to a shorter portion of cable. Now walk in a circle 10 to 25 feet away from the pedestal, holding the receiver so that it points at the pedestal - not so that it is aligned with your circular path. When you get a response, stop, find the peak, and adjust gain. Make a note of the numeric strength reading. Now continue walking around the pedestal and repeat these steps each time you get a response. When you have completed the circle, the response with the highest strength reading is the targeted cable, and may be traced as needed. strong signal buried drops weak signal pedestal feet 31
32 5 SONDE LOCATING Sondes, or also referred to as transmitting beacons, are battery operated devices for specific applications to detect various constructed material pipes either metallic or non-metallic pipe. The sonde emits a particular frequency utilize to achieve best results.. Sondes in the Herz ((Hz) range are beneficial for deeper applications from 8 to 15 feet, and is capable of signal penetration through dense pipe materials such as steel, cement and clay tile pipes. Sondes in the kiloherz (khz) range are best used for shallow depths from 1-8 feet and are generally detected through lighter dense pipe materials as plastic pipes for example. A sonde performance will be adversely affected if the battery charge is weak. Sonde Detection: The pipe & cable locator receiver must have a frequency selection that identically matches the frequency and modulation of the sonde being detected. The TraceMaster is capable with optional programming to detect one of these sonde models - TM50911 (512Hz), TM50910 (512Hz) or TM82KHZ-T (82 khz). Model XTpc82 is capable with optional programming to detect one of these sonde models - TM50911 (512Hz), TM50910 (512Hz) or TM82KHZ-T (82 khz). Model XTpc33 is capable with optional programming to detect one of these sonde models - TM50911 (512Hz), TM50910 (512Hz) or TM33KHZ-T (33 khz). Model XT512 is capable with optional programming to detect sonde models TM50911 (512Hz) and TM50910 (512Hz) Searching for the Sonde: Due to the nature and strength of the sonde signal, it is necessary to have some general idea of where the sonde is. To narrow the search area to a circle of several feet radius centered at the sonde. This is usually not much of a problem, since the sonde is "guided" by a device under control of the work crew. Once in the surroundings of the sonde, it is important to differentiate whether you are positioned along the axis of the sonde (the direction of the pipe) or off to either side. In the sonde mode the directional arrows on a locator are not functional, so the signal strength is the only indication available, and it will be "null" (very close to zero) if the receiver is placed on the axis of the sonde with the plane of the sensors perpendicular to it. Rotate the locator's axis and the direction that results in increasing signal strength. Rotate the receiver back and forth and move in the direction that produces the maximum signal strength. As the receiver gets closer to the sonde the signal strength increases to a maximum when directly over the sonde. The plane of the sensors will be directly parallel to the axis of the sonde at this time. 32
33 See diagrams below. Showing receiver orientation in Peak or maximum signal strength detection. (Orientation needed for depth measurement) Showing receiver orientation in Null or lowest signal strength detection. For best results, keep sonde stationary when locating signal. Ensure receiver and sonde are aligned as shown above, either in Peak or Null orientation. Measuring Depth of Sonde: To measure depth simply place the tip of the locator on the ground and press the DEPTH button when the signal strength is at a maximum. Orientation (axis) of locator as shown if Diagram A is crucial for depth accuracy. Sensors in locator must be parallel to the axis of the sonde to achieve best depth measurement results. Pipe Diameter Limitations & 90 Bends: Due to various dimensions of sondes, it is important to be aware of limitations to push through 90 or otherwise bends in pipes. The TM50911 Sonde is a watertight designed that can maneuver through 90 turns in 1.5" inch (38 mm pipe). The TM50910 Sonde is a watertight design that can maneuver through 90 turns in 3 inch (76 mm pipe). The TM82kHz & TM33kHz are a watertight design and can maneuver through 90 turns in 4 inch (102 mm pipe). 33
34 Sonde Specifications & Dimensions: TM50910 TM50911 TM33kHz-T or Large Small TM82kHz-T FREQUENCY: 512 Hz 512 Hz 33 khz or 82 khz SIZE(IN.): 1 3/4 X 6 3/4 3/4 X 2 1 X 4 1/2 WEIGHT(OZ.) BATTERY: 2-AA 1-N 1-AAA BATTERY LIFE: 4-6 hours 4-6 hours 4-6 hours continuous 70 F (21 C) ADAPTERS: 3/8-16Thread 1/4-20 Thread 3/8-16 Thread 3/8" Set Screw 1/4-20 Thread OPERATING TEMP RANGE: 32 F (0 C) to -4 F (-20 C) to 32 F (0 C) to 140 F (60 C) 122 F (50 C) 140 F (60 C) DEPTH RANGE: FT max 8-10 FT max 6-8 FT max (soil type dependent) Maintenance & Storage of Sonde: Sonde housings should be thoroughly wash & dry after use. Remove battery and replace battery cap for storage. 34
35 6 MAGNETIC LOCATING Theory of Operation: Magnets can be defined as bodies that produce external magnetic fields; these fields are bipolar, that is, they will have a positive pole where the field emanates from the object and a negative pole where the field returns. The shape and size of this external field is directly related to the magnet s strength. Magnetic locators work by detecting the two types of magnetization that can be produced by underground ferrous (iron or steel containing) objects. The first type is the weak field induced naturally by Earth s magnetic field. All ferrous objects have this field, and in the Northern Magnetic Hemisphere this field is always positive. The second type is an artificially induced permanent magnetization. When this type of field is present, it is usually quite strong. The field orientation varies depending on how the object was magnetized. Magnetic locators have two sensors vertically separated about 8 to 20 inches that give a reading when the two sensors are detecting different magnetic field strengths. So when the lower sensor (typically) is near a ferrous object, it will detect a stronger field than the upper sensor and trigger a response, which is usually an audio signal rising in pitch but can also be a numeric indication or bars on a screen. Searching with a Magnetic Locator: Begin with the sensitivity control set to normal. Be aware of metal on your person that can distort readings, such as wristwatches or steel toed boots - you may want to remove these or hold them away from the locator. Sweeping the locator from side to side is the most generally useful way to cover a large area - when the locator comes close to a ferrous object you will get a response. If your locator has a visual display that distinguishes between positive and negative polarity, you can often tell if you have found a vertically or horizontally oriented pipe. If vertical, the reading will be either positive or negative and will not have a corresponding and opposite reading nearby. If two or more vertical pipes are buried close to each other, they will usually produce similar polarity readings. If horizontal, the polarity reading will be negative at one end of the pipe, positive at the other end, and significantly weaker between the two ends. 36
36 - or Audio Signal Pinpointing an Object: Once you have detected an object by sweeping, you can locate it more precisely by slowing down and holding the locator vertically over the reading. Move the locator in an X pattern and home in on the strongest response in both directions. The X pattern will pinpoint the ends of large objects, and the exact location of small objects. Adjusting Sensitivity: Sensitivity to underground objects can be reduced in two ways: raising the locator several inches, or reducing the gain control. Raising the locator can give valuable information regarding the size of the underground object. If the object is small, such as a bolt or nail, the signal will decrease quickly as the locator is raised. But the signal will decrease much more gradually if the object is large, such as a length of rebar used as a survey marker. Most magnetic locators can detect an 18 inch section of rebar buried as deep as seven feet. + OR - + OR - Audio signal higher above ground Audio signal close to ground Small Bolt Corner Marker 37
37 Strongly Magnetized Markers: When a ferrous object with a very strong field is near the surface there will be a peak signal directly over the object, but there will also be weaker but still distinct signals on both sides of the marker that could be mistaken for separate objects. Referring to the illustration below, the heavy line shows the characteristics of all three readings. From A to B and from C to D, there is a smooth, gradual increase and decrease in signal strength, while from B to C there is a much more abrupt rise and fall in signal strength, with a stronger peak response. The weak signals on either side of the object are due to the locator s extreme sensitivity to aspects of the magnetic field parallel to its (the receiver s) vertical axis. At points B and C the magnetic field intersects this axis perpendicularly, reducing the difference in readings between the two sensors. The best way to avoid being fooled by these weaker but distinct signals is to sweep well before pinpointing. AUDIO SIGNAL A + OR - B 0 + OR - C 0 D + OR - IRON PIPE How to Search Near a Chain Link Fence: To search near a chain link fence, reduce the gain setting and hold the locator horizontally, as shown in the illustration, with its long axis at right angles to the fence - this keeps the upper sensor away from the fence. Search by sweeping the locator side to side as well as forward and back. By this means you can search a swath several feet wide along the base of the fence. 38
38 When the lower sensor - which is a few inches from the end of the locator and should be the sensor closest to the fence - is directly over a ferrous object there will be a sudden drop in signal strength. As you move the lower sensor away from the object, response will rise just as abruptly. + signal Null with locator as shown 1-5/8 Locating Metallic Pipe: Long ferrous objects, such as pipe, have magnetic fields that reach out beyond their ends. In the case of metallic pipe, this even applies to pipe sections that have been welded together - there will be peak readings at the welded joints. + or / 2 FEET + or - 39
39 When tracing pipe, set the gain at maximum and hold the locator between one and two feet above ground level. Holding the locator steady, walk along the suspected pipe s path, making temporary marks at any readings - don t try to pinpoint yet. When you have several marks in your area of concern, reduce the gain for a second pass and hold the locator closer to the ground, pinpointing the peak response near the previously marked points. These marks at peak response will reveal the pipe s location. Magnetic locators can get a signal from four inch pipe set as deep as eight feet. How to Locate in Cluttered Areas: One approach to searching in cluttered areas is to sharply reduce the locator s sensitivity before sweeping. The locator will not detect smaller objects, but will still respond to larger objects. To find very large objects, such as steel cisterns or tanks, you can raise the locator several feet above ground level. Small objects near the surface will not be detected, but deep, very large objects will. When locating rebar in concrete, keep in mind that readings will be strongest at rebar ends, but also consider that steel ties at rebar intersections will also give strong readings. Points to Keep in Mind When Using a Magnetic Locator: Magnetic locators will only detect magnets or ferrous (iron containing) objects, including but not limited to rebar, magnets, pipes, weapons, ordnance, old tin cans, bolts, PK nails, etc. Joints in pipe will be detected, even welded joints. Some large non-ferrous objects, such as septic tanks, may have metal components, such as handles, that can be located. Energized power lines, 50/60 cycle, will give a reading with an easily recognizable warble. Magnetic locators can detect magnetic fields through any non-magnetic material, including snow and water, just as well as they can through dirt or concrete. But do not hold the locator in water as the water may damage the sensors or electronics. When performed skillfully, magnetic locating can detect an object as small as a PK nail, within a circle as tight as 1/2. Non-ferrous metallic objects, such as gold rings, copper wire, aluminum cans or silverware, will not be detected. 40
40 Schonstedt Instrument Company 100 Edmond Road Kearneysville, WV Making Locating Easier Since 1953
Cable and Pipe Locating Techniques
Cable and Pipe Locating Techniques for use with 3M Dynatel Cable and Pipe Locators August 1998 80-6108-6216-3-C 1 2 Table of Contents Section 1 The Basics of Cable Locating 1. Introduction... 7 2. Applying
Cable And Pipe Signal Receiver
OPERATION AND SAFETY INSTRUCTION MANUAL Cable And Pipe Signal Receiver Part 17-300R Cable And Pipe Signal Receiver Part 17-300RTK Cable And Pipe Signal Receiver With Transmitter Part 17-500T Transmitter
Dynatel 2273 Advanced Cable and Fault Locator
Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
RD2000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T1 Transmitter User Guide
RD000 SuperC.A.T RD000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T Transmitter User Guide RD000 SuperC.A.T User Guide Functions SuperC.A.T Locator functions 4 6 On/Off Trigger. Press and
C.A.T and Genny User Guide. Revision 3-06.00
C.A.T and Genny User Guide Revision 3-06.00 Troubleshooting When reporting any problem to your Radiodetection Dealer/Supplier it is important to quote the Receiver Serial Number. Warning: Radiodetection
Model 450 Mag Horn Ferromagnetic Locator
Model 450 Mag Horn Ferromagnetic Locator User s Manual Manufactured Exclusively By: Utility Tool Company, Inc. 2900 Commerce Boulevard Birmingham, Alabama 35210 205-956-3710 User s Hotline 800-952-3710
Operating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED
Electric Service Guide for Residential Construction
Electric Service Guide for Residential Construction Table of Contents Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Changing your electric service... 2 What you need to know before you
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
Chapter 22: Electric motors and electromagnetic induction
Chapter 22: Electric motors and electromagnetic induction The motor effect movement from electricity When a current is passed through a wire placed in a magnetic field a force is produced which acts on
Table of Contents. Fault Finding Solutions
FAULT FINDING SOLUTIONS WWW.MEGGER.COM Table of Contents Section I Cable Characteristics II III IV Page Good Cable Insulation....................2 When Cable Insulation is Bad..............2 Why a cable
Application Note. Troubleshooting Communications
ANX Application Note Troubleshooting Communications This document is a guide for basic troubleshooting of UPB communication issues. There are two things that can disturb UPB communications: noise and attenuation.
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12
Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of
Indoor Environment Electromagnetic Radiation
Indoor Environment Electromagnetic Radiation Purpose: To increase the students awareness of the sources of electric and magnetic fields and the potential for adverse health effects from prolonged exposure
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
Chapter 9. Bonding and Grounding
Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE
CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE 8.1 SYSTEM 8.1.1 Armoured, screened underground cables are used for control communication in electrified areas to limit induction effect. 8.2
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
GLOLAB Universal Telephone Hold
GLOLAB Universal Telephone Hold 1 UNIVERSAL HOLD CIRCUIT If you have touch tone telephone service, you can now put a call on hold from any phone in the house, even from cordless phones and phones without
Leica DIGISYSTEM TM Safe and fast location of underground services
Leica DIGISYSTEM TM Safe and fast location of underground services Find it or avoid it the Leica DIGISYSTEM is your Key Why locate Brownfield sites have many and varied installed services and utilities
EH-20 20m antenna. By VE3RGW
EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Requirements for the Attachment of Communication Cable Facilities on PPL Poles
Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication
Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers
Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers Near-Surface Marker A small marker which is well-suited for bore holes in concrete or asphalt for marking flush-mount
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow
ingle Conductor Cable Copper heathed Cable heath Currents ingle conductor cables present certain application considerations that do not arise in multiconductor cable installations. These considerations
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 WARNING 12-32 VDC
SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 } 12-32 VDC Specifications 032-044-000 and 032-045-000 WARNING Hazardous voltage. This Leak Detector is an electrical device.
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
Security Cameras, CATV, GPS & Satellite Protection. White Paper
Security Cameras, CATV, GPS & Satellite Protection White Paper Security Cameras, CATV, GPS & Satellite Protection Surge Protection Solutions for PTC 1 Security Cameras, CATV, GPS & Satellite Protection
TELIKOU Intercom System. TM-200 Main Station. Instruction Manual
Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television
************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D
************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance
TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual
TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
TEL: +44 (0) 1295 266277 FAX: +44 (0) 1295 268199 [email protected]
TEL: +44 (0) 1295 266277 FAX: +44 (0) 1295 268199 [email protected] UNIT G165 Cherwell Business Village BANBURY Oxfordshire OX16 2SP United Kingdom Using Leaky Feeder We ve been selling Times Microwave
Electric Service Guide for Commercial Construction
Electric Service Guide for Commercial Construction Contents Contacting KCP&L... 2 Voltages... 2 Temporary Service... 2 Customer-Provided Temporary Service... 2 KCP&L-Provided Temporary Service.... 2 Current
The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.
260 17-1 I. THEORY EXPERIMENT 17 QUALITATIVE STUDY OF INDUCED EMF Along the extended central axis of a bar magnet, the magnetic field vector B r, on the side nearer the North pole, points away from this
The Basics of Loop Vehicle Detection
The Basics of Loop Vehicle Detection There are a number of ways to detect vehicles, ranging from hose style detection to ultra-sonic, to inductive loop. For traffic control or drive-thru, inductive loop
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING
REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING Revised October, 2013 TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 REQUIRED DRAWINGS... 3 2.1 Site Plan... 3
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
SURE-LOCK Utility Pro User Manual
SURE-LOCK Utility Pro User Manual Proprietary Notice The contents of this manual are proprietary to Heath Consultants Incorporated. Reproduction of this manual, in whole or in part, is prohibited without
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
1. The diagram below represents magnetic lines of force within a region of space.
1. The diagram below represents magnetic lines of force within a region of space. 4. In which diagram below is the magnetic flux density at point P greatest? (1) (3) (2) (4) The magnetic field is strongest
Strength and Durability for Life CORROSION CONTROL. The Effect of Overhead AC Power Lines Paralleling Ductile Iron Pipelines
Strength and Durability for Life CORROSION CONTROL The Effect of Overhead AC Power Lines Paralleling Ductile Iron Pipelines Last Revised: May 2016 Sharing of rights-of-way by AC power lines and buried
AC and DC Drive System Installation Information
Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS
3. TYPES OF SERVICE AVAILABLE. 3.1 Scope
3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service
Overview of the Telecommunications Network
1 Overview of the Telecommunications Network 15 Telecommunication Networks 2 Basic purpose of a telecommunications network: transmit user information in any form to another user of the network. Many forms
FAQ s on Siemens Magmeters
FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables
White Paper: Electrical Ground Rules
Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment
Installation Instructions Hustler 6-BTV Trap Vertical
Installation Instructions Hustler 6-BTV Trap Vertical ASSEMBLY 1. Check the package contents against the parts list on page 2. 2. WARNING. Installation of this product near power lines is dangerous. For
Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.
Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist. Abstract. I have been asked to put together a detailed article on a SWR meter. In this article I will deal
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
OPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes
Optical Cable Pre-Construction Survey Author John Peters Issued December 2012 Abstract Pre-construction site survey is one of the most important steps in the engineering and placement of a new optical
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.
MPA-101 WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation. The lightning flash with arrowhead, within an equilateral triangle,
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
Electric Service Guide for Residential Construction
Electric Service Guide for Residential Construction TABLE OF CONTENTS Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Building a New Home... 3 KCP&L Services at a Glance... 4 Current Transformers...
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
Solstice/Sky Water Pump Replacement
Solstice/Sky Water Pump Replacement The water pump on the Solstice/Sky is starting to need replacement on some vehicles. This guide will help in replacing the water pump while the engine is still in the
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
LocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
Your Simple Guide to Battery. www.firstalertpro.com. Replacement. Customer Care: 1-800-852-0086. www.firstalertpro.
Previous Menu Your Simple Guide to Battery www.firstalertpro.com Replacement p e t s ts ep -by Customer Care: 1-800-852-0086 FA/1565 9/00 www.firstalertpro.com Table of Contents: page Introduction...............................
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
Lab 3 - DC Circuits and Ohm s Law
Lab 3 DC Circuits and Ohm s Law L3-1 Name Date Partners Lab 3 - DC Circuits and Ohm s Law OBJECTIES To learn to apply the concept of potential difference (voltage) to explain the action of a battery in
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
SELF INSTALLATION GUIDE
Ultrafast Fibre-optic Broadband SELF INSTALLATION GUIDE Gigaclear install permission July2012 v1.0 Before you begin Please make sure you have the correct length of cable. Bear in mind that you may need
SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation
MAINTENANCE & ADJUSTMENT
MAINTENANCE & ADJUSTMENT Circuit Theory The concept of PLL system frequency synthesization is not of recent development, however, it has not been a long age since the digital theory has been couplet with
STREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55
NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55 Quick Start S This device is a Z-Wave Sensor. Inclusion and Exclusion are confirmed by triple clicking the Z-Wave button on the device.
Differential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5
Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5 www.pyleaudio.com Instruction Manual Installation and Connection: 1. Please disconnect your car battery. 2. In the contents
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
Oscar E. Morel UtilX Corporation
Oscar E. Morel UtilX Corporation Time Domain Reflectometry (TDR) has been the preferred technique to assess: Cable length Splice number and spatial location, and Metallic neutral condition Tests for neutral