How-To-Do. Hardware Configuration SLIO CPU 014



Similar documents
How-To-Do. EtherCAT Communication with CPU 300S

FAQ Communication over IE

How-To-Do. Firmware Update Speed7 and project backup on the MMC card

1 Application Description Objective Goals... 3

TECHNICAL NOTE TNOI34

Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Service & Support. How can you establish a connection between an S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Commissioning IDENTControl Compact IC-KP2-2HB17-2V1D Profinet Protocol with a Siemens S7 PLC

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

Manual. VIPA WinNCS. Order no.: VIPA HB91E Rev. 04/03

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

Redundant PROFIBUS DP network with S7-400H System and Ponto PO5063V5 Remote

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

CPUs - CPU PN/DP

s Preface SIMATIC Configuring Hardware and Communication Connections with STEP 7 Contents Basics of Configuring Hardware with STEP 7 1

PROFINET IO Diagnostics 1

8/23/13 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) MODULE M1

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

Cover sheet PROFINET IO. SIMATIC MV440 Code Reading System. FAQ February Service & Support. Answers for industry.

Application Note Profinet Modules

SIMATIC. PROFINET IO Getting Started: Collection. CPU PN/DP: Configuring PROFINET interface X2

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010

SOFTLINK 300. CPU Specifications. Reference Manual

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

1 How configure S7 PLC in the configuration tool

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

S7 OPC Server Tutorial

Applications & Tools. Master Slave Communication via a CM PtP using the Modbus RTU Protocol. S CM PtP RS422/485 HF, ET 200SP CM PtP

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Data sheet SLIO CPU 015 (015-CEFPR00)

GE Proficy Machine Edition Profibus/Profinet SARTUP GUIDE

Ethernet Module Manual

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

Installation Manual. PLCSQL link

SIMATIC The Process Device Manager Manual Edition 12/2004 A5E

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG All Rights Reserved.

Using a Modbus TCP to Profibus PA Gateway by IFAK system

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

SIEMENS S

FACTORY AUTOMATION. Manual Commissioning IDENTControl IC-KP-B12-V45 and IC-KP-B17-AIDA1 with PROFINET Protocol to Siemens S7 Controller

CP Page 1342 Mar 2008 Siemens ITS

Applications & Tools. Connecting a SINAMICS G120 Drive to an S7-300/400 CPU in TIA Portal V11 SINAMICS G120 (CU 240E-2 PN(-F)), SIMATIC S7-300/400

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

The CP provides access to different communication services of the PROFIBUS bus system:

SIMATIC PDM software. Siemens FI /1

SIMATIC NET. Installation Instructions. INSTALLATION INSTRUCTIONS for the CP 5412 (A2) C79000-Z8974-C Stand / Dated 04/98

SIMATIC. Windows Automation Center WinAC Slot Version 4.0. Preface, Contents. Product Overview 1. Installing the CPU 41x-2 PCI.

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

Configuring Windows 7 64 bit for AutoVISION

FAQ about Drive Technology

VIPA System 500S. SPEED7 - CPU 515-2AJ02 Manual

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

1 Application Description System Topology Hardware and Software Requirements... 3

The CP FO provides access to different communication services of the PROFIBUS bus system:

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 "RDREC" FAQ September Service & Support. Answers for industry.

The goal is to program the PLC and HMI to count with the following behaviors:

PROFINET Diagnostics Software and Tools

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Lean. Manual Part B. Release 09/2009 C79000-G8976-C198-06

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

6ES BE01-0AB0 6ES BE01-0AB0

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Tool for Communication

Beckhoff TwinCAT. Assigning IP Addresses to Beckhoff Ethernet Devices

GW-7552 PRIFIBUS/MODBUS GATEWAY

Creating a new project up to a working PES

QuickPanel Control DeviceNet Master Communications Card (IC754DVNM01) Quick Start Guide. Thursday September 20, 2007

Web server SIMATIC. S Web server. Preface. Documentation guide. General information. Websites 3. Function Manual 12/2014 A5E AD

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

Cover PROFINET IO. Code Reader System SIMATIC MV440 / MV420. FAQ June Service & Support. Answers for industry.

ATV71 and ATV32 on Ethernet/IP with M340 and NOC0401 configured on Unity V6.0. Assemblies 20 70

Plena Voice Alarm System Firmware update

Ponto Series. A new concept for automation

Flexi Soft Ethernet IP: Implicit Messaging with a Omron PLC

User Manual Document HTTP-Direct / FTPServer and FLASH file system

SIMATIC NET. S7-CPs for Industrial Ethernet Configuring and Commissioning

BASLER ACE QUICK INSTALLATION GUIDE

Applications & Tools. Remote Control Concept with SCALANCE S Modules over IPsec-secured VPN Tunnel SCALANCE S. Application Description February 2010

Manual. MOVIFIT Function Level "Classic" Edition 05/ / EN

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Transcription:

How-To-Do Hardware Configuration SLIO CPU 014 With the SIMATIC Manager from the SIEMENS AG Content 1 General... 2 1.1 Information... 2 1.2 Reference... 2 2 Step by step Hardware Configuration... 3 2.1 Configuration of the SLIO CPU 014-CEF0R00... 3 2.2 Enabling the PROFIBUS Functions and the Memory Extensions... 11 2.3 Configuration of the PROFBUS Master System... 13 3 Revision History... 18 3.1 Änderungen:... 18 Januar 14 page 1 of 18

1 General 1.1 Information This How-To-Do describes, how you can configure the VIPA SLIO CPU 014-CEF0R00 in the SIMATIC Manager from Siemens. This includes the configuration of a PROFIBUS master / slave system as well as the enabling of PROFIBUS and memory extensions via VSC (VIPA Set Card). You can find a detailed description of the SLIO CPU 014-CEF0R00 in the manual under the link: SLIO CPU 014-CEF0R00 http://www.vipa.com/de/service-support/manuals/io-systems/slio/ 1.2 Reference In this How-To-Do principal procedures are described by means of examples. You can download the required GSDML file from the website http://www.vipa.com/de/service-support/downloads/. Liability for material defects and defects of this documentation, especially for the correctness, accuracy, freedom and protection or third party rights, completeness and / or usability - except for willful misconduct or bad faith - are excluded. Januar 14 page 2 of 18

2 Step by step Hardware Configuration 2.1 Configuration of the SLIO CPU 014-CEF0R00 1. Start the SIMATIC Manager from SIEMENS AG and open a new projekt. Project Explorer Project Window Picture 1: Structure of the SIMATIC Manager from SIEMENS AG 2. Insert a SIMATIC 300-Station. Picture 2: Configuration of a SIMATIC 300 Station Januar 14 page 3 of 18

3. Select the new integrated SIMATIC 300-Station and open the HW Config by double click on Hardware. Picture 3: Opening the HW Config in a new window Stations Window HW- Catalog Details about the selected Station Picture 4: Structure of the HW Config in the SIMATIC Manager from SIEMENS AG 4. Navigate in the HW-Catalog to the folder SIMATIC 300 -> Rack-300 and integrate the object Rail into the Station Window via Drag&Drop. Picture 5: Integration of a profile rail into the station window Januar 14 page 4 of 18

5. For configuration of the VIPA SLIO CPU 014-CEF0R00 select the folder SIMATIC 300 -> CPU- 300 -> CPU 315-2PN/DP -> 6ES7 315-2EH14-0AB0. Select the CPU 315-2 PN/DP (6ES7 315-2EH14-0AB0 V3.2) and insert it into Slot 2 of the 300 rack via Drag&Drop. Picture 6: Integration of the CPU 315-2 PN/DP into the 300 rack 6. Now a dialogue window opens, in which you can configure the Ethernet interface of the CPU. The Ethernet interface is applied for the virtual backplane bus (SLIDE-Bus) as well as for the PROFINET system. Fill in the requested IP address and subnet mask of your CPU (PROFINET System) into the dedicated fields. For creation of a new Ethernet line click on <New>. 1 2 Picture 7: Parameterization of the Ethernet (SLIDE-Bus /PROFINET) interface of the CPU Januar 14 page 5 of 18

7. In the properties window you can name your Ethernet subnet. In this How-To-Do example the subnet is named SLIDE-Bus. Close both windows with <OK>. Picture 8: Assigning names for the subnet of the CPU (SLIDE-Bus) 8. Now you should see the CPU 315-2 PN/DP with the appended Ethernet rail in the station window. Picture 9: CPU 315-2 PN/DP with SLIDE-Bus System Januar 14 page 6 of 18

9. For configuration of the Ethernet PG/OP channel of the VIPA SLIO CPU 014-CEF0R00 select the folder SIMATIC 300 -> CP-300 -> Industrial Ethernet -> CP 343-1 -> 6GK7 343-1EX21-0XE0. Select the CP343-1 (6GK7 343-1EX21-0XE0 V1.2) and insert it into slot 4 of the 300 rack via Drag&Drop. Picture 10: Insert the CP 343-1 into the 300 rack 10. Now a dialogue windows opens, in which you can configure the Ethernet interface of the CP. Fill in the requested IP address and subnet mask of your CP (PG/OP channel)) into the dedicated fields. For creation of a new Ethernet line, in this case for the PG/OP channel of the VIPA CPU, click on <New>. 1 2 Picture 11: Parameterizing the PG/OG interface of the CPU via the CP 343-1 Januar 14 page 7 of 18

11. In the properties window you can name your Ethernet subnet. In this How-To-Do example the subnet is named PG/OG Interface. Close both windows with <OK>. Picture 12: Naming the subnet of the CP (PG/OG interface) 12. After the successful creation of the Ethernet line you now should see a CP 343-1 in the Slot 4 of the CPU 315-2 PN/DP. Picture 13: CPU 315-2 PN/DP with SLIDE-Bus system and PG/OG interface (CP343-1) Januar 14 page 8 of 18

13. For the following steps the GSDML file Cx000166.gsdml must be installed in the hardware catalog. You can download a zip file containing the GSDML under the following link: GSDML for the SLIO CPU 014-CEF0R00: http://www.vipa.com/de/service-support/downloads/ 14. Navigate in the HW Catalog to the folder PROFINET IO -> Additional Field Devices -> I/O -> VIPA SLIO System and insert the object 014CEF0R00 CPU into the before added PROFINET line (SLIDE-Bus system) via Drag&Drop. Picture 14: Inserting the SLIO CPU 014-CEF0R00 15. Now you can append the IO modules to the configured SLIO CPU 014. Navigate in the HW Catalog to the folder PROFINET IO -> Additional Field Devices -> I/O -> VIPA SLIO System -> 014-CEF0R00 CPU and select your required I/O modules. Insert them into the slots of the SLIO CPU 014 (beginning with slot 1) via Drag&Drop. In this How-To-Do example the following module is applied: 1x DO 8xDC24V 0,5A 022-1BF00 (Slot 1) [up to 64 IO modules configurable] Picture 15: Appending the IO module to the SLIO CPU 014 Januar 14 page 9 of 18

16. When you have finished, move to the menu Station > save and compile, or click on the symbol in the menu bar for compilation and saving of the configuration. 17. Connect the PLC and your PC via Ethernet. 18. With the menu item <PLC -> Download> or with the symbol you can transfer your hardware configuration into your PLC. Januar 14 page 10 of 18

2.2 Enabling the PROFIBUS Functions and the Memory Extensions The PROFIBUS master/-slave functions as well as the memory extensions (+ 64kBytes, + 128kBytes, + 256kBytes) can be enabled by the VIPASetCards (VSC). The following spreadsheet contains the order numbers of the VSCs for the several function extensions and memory extensions: - + 64KByte + 128KByte + 256KByte - 955-0000000 955 - C000020 955 - C000030 955 - C000040 PROFIBUS-Master 955 - C000M00 955 - C000M20 955 - C000M30 955 - C000M40 PROFIBUS-Slave 955 - C000S00 955 - C000S20 955 - C000S30 955 - C000S40 1. To execute the respective functions and memory extensions you must insert the suitable VSC into your SLIO CPU 014. In the How-To-Do example the VSC 955-C000M30 (PROFIBUS master + 128KByte) is applied. 2. Now you must execute Clear memory in the SLIO CPU 014. Here there are two possibilities: a. Memory Reset via SIMATIC Manager from SIEMENS AG 1. Select the configured Siemens-Dummy-CPU in the Hardware configurator of the SIMATIC Manager from SIEMENS AG. Then execute the memory reset via the menu <PLC -> Clear/Reset>. Picture 16: Clear Memory of the SLIO CPU 014 Januar 14 page 11 of 18

b. Memory Reset via the operating mode switch of the CPU 1. Switch your SLIO CPU 014 into the STOP status. Therefor switch the operating mode switch on STOP. The STOP LED is on. 2. Position the operating mode switch into MRES and hold it approximately 3 seconds. The STOP LED changes from blinking to continuous light. 3. Position the operating mode switch into STOP and within 3 seconds shortly into MRES, then again into STOP. The STOP LED is blinking (Memory reset is running). 4. The memory reset has been finished, if the STOP LED changes into continuous light. The STOP LED is on. 3. For checking the activation of the function extensions and memory extensions please open the website of the SLIO CPU 014 (in the How-To-Do example accessible via the IP address 192.168.1.14) and then move to the Expert view. Picture 17: PROFIBUS Master Function and 256KByte Memory Extension Januar 14 page 12 of 18

2.3 Configuration of the PROFBUS Master System 1. Use the hardware configuration of chapter 2.1. 2. If the PROFIBUS master function is not yet enabled, please follow the description in chapter 2.2. 3. Open the MPI(DP) interface of the CPU to configure it from MPI to PROFIBUS master via double click. Picture 18: Open properties of the MPI/DP interface 4. Now change the type of the interface from MPI to PROFIBUS. Then open the properties of the interface to parameterize the interface. 1 2 3 Picture 19: Changing the interface from MPI to PROFIBUS Januar 14 page 13 of 18

5. Now create a PROFIBUS System via clicking on the button <New...>. Then select it, before you can close again the window by the button <OK>. Picture 20: Selecting a new PROFIBUS system 6. Now you have created a PROFIBUS system for your configured PROFIBUS interface. You can assign this system with an unique name. Then close all windows with the button <OK>. 1 2 Picture 21: Creating a new PROFIBUS system Januar 14 page 14 of 18

7. Now you should see a PROFIBUS System in your hardware configuration additionally to the SLIDE BUS. Picture 22: SLIO CPU 014 incl. the new projected PROFIBUS system 8. Select a PROFIBUS communication participant for the SLIO CPU 014 out of the hardware catalog. In the How-To-Do example a SLIO IM 053DP is configured. You can find it in the folder: 1x IM 053DP 053-1DP00 Navigate in the hardware catalog to the folder PROFIBUS DP -> Additional Field Devices -> I/O - > VIPA SLIO and add the VIPA IM module (053-1DP00 DPV1), which is contained in this folder, to the PROFIBUS system via Drag&Drop. Picture 23: Adding the IM 053 to the PROFIBUS system Januar 14 page 15 of 18

9. If you have added the IM 053 to your hardware configuration, the properties window of the DP slave opens. Here you can name the slave individually and adjust the PROFIBUS address of the IM 053 via the button <PROFIBUS >. 1 2 Picture 24: Parameterization of the PROFIBUS slaves 10. Now please adjust the PROFIBUS address of the SLIO IM 053 (VIPA053-1DP000). Therefor adjust the required PROFIBUS address via dip switch of the SLIO IM 053 (in the How-To-Do example Address 3). Now fill in this PROFIBUS address into the dedicated input field, mark your PROFIBUS system and close the window with the button <OK>. 1 2 3 Picture 25: Changing the PROFIBUS device name of the VIPA IM 053 Januar 14 page 16 of 18

11. Now you can append the I/O modules to the the projected SLIO IM 053. Navigate in the hardware catalog to the folder PROFIBUS-DP -> Additional Field Devices -> I/O -> VIPA_SLIO -> 053-1DP00 DPV1 and select the required I/O modules. Add them to the slots of the SLIO IM 053 (starting with slot 1) via Drag&Drop. In the How-To-Do example the following modules are applied: 2x DO 8xDC24V 0,5A 022-1BF00 (from Slot 1) [up to 64 I/O modules configurable] Picture 26: Add IO-modules to the IM 053 12. If you have finished, move to the menu Station > Save and Compile, or click on the symbol in the menu bar to compile and save the configuration. 13. Connect the PLC to your PC (PG/OP Interface [X1]) and the PLC (PROFIBUS Interface [X3]) to the SLIO IM 053 (PROFIBUS interface [X1]) via PROFIBUS. 14. Via Clicking on the menu point PLC > Download or on the symbol you can transfer your hardware configuration into your PLC. Januar 14 page 17 of 18

3 Revision History 3.1 Änderungen: DATUM ÄNDERUNGEN BEARBEITER 10.01.2014 M. Dörnhöfer 09.01.2014 Übersetzungsüberprüfung durchgeführt M. Dörnhöfer 11.12.2013 Erstellung Dokument M. Dörnhöfer Januar 14 page 18 of 18