Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications....................................................... 3 Nominal Capacity And Nominal Input................................ 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 4 3 Electrical data....................................................... 5 Electrical Data........................................................ 5 4 Capacity tables..................................................... 6 Cooling/Heating Capacity Tables.................................... 6 5 Dimensional drawings............................................. 8 Dimensional Drawings............................................... 8 6 Centre of gravity.................................................... 9 Centre of Gravity..................................................... 9 7 Piping diagrams................................................... 0 Piping Diagrams.................................................... 0 8 Wiring diagrams................................................... Wiring Diagrams - Single Phase................................... 9 Sound data......................................................... 2 Sound Pressure Spectrum.......................................... 2 0 Operation range................................................... 4 Operation Range.................................................... 4 Split - Sky Air Outdoor Unit
k i n n a t - s r o t r o i od J l ot - pl u F Outdoor Unit RX-JV Features d S U V X SO R Outdoor units for pair application Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency Energy efficient units: up to class A energy labels Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall 2 Split - Sky Air Outdoor Unit
2 Specifications Outdoor Unit RX-JV 2- Nominal Capacity And Nominal Input FTX20JV / RX20JV FTX25JV / RX25JV FTX35JV / RX35JV Cooling capacity Min. kw.3 Btu/h 4,400 kcal/h,20 Nom. kw 2.0 2.5 3.3 Btu/h 6,800 8,500,300 kcal/h,720 2,50 2,840 Max. kw 2.6 3.0 3.8 Btu/h 8,900 0,200 3,000 kcal/h 2,240 2,580 3,270 Heating capacity Min. kw.3 Btu/h 4,400 kcal/h,20 Nom. kw 2.5 2.8 3.5 Btu/h 8,500 9,600,900 kcal/h 2,50 2,40 3,00 Max. kw 3.5 4.0 4.8 Btu/h,600 3,600 6,400 kcal/h 3,00 3,440 4,30 Power input Cooling Nom. kw 0.550 0.730 0.980 Heating Nom. kw 0.590 0.690 0.930 EER 3.64 3.42 3.37 COP 4.24 4.06 3.76 Annual energy consumption kwh 275 365 490 Energy label Cooling A Heating A Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 Drain OD mm 8 Heat insulation Both liquid and gas pipes 3 2 2-2 Technical Specifications RX20JV RX25JV RX35JV Casing Colour Ivory white Dimensions Unit Height mm 550 Width mm 658 Depth mm 275 Packed unit Height mm 66 Width mm 788 Depth mm 359 Weight Unit kg 28 30 Packed unit kg 3 34 Heat exchanger Length mm 670 647 Rows Quantity 2 Fin pitch mm.4 Stages Quantity 24 Tube type ø7 Hi-XA Fin Type Waffle louvered fin Fan Type Propeller fan Air flow rate Cooling High m³/min 29.2 27.60 cfm,030 975 Super m³/min - low cfm - Heating High m³/min 26.2 24.5 cfm 927 865 Super m³/min - low cfm - Split - Sky Air Outdoor Unit 3
2 Specifications Outdoor Unit RX-JV 2 2-2 Technical Specifications RX20JV RX25JV RX35JV Fan motor Model KFD-280-33-8A Output W 33.00 Speed Cooling High rpm 860 Low rpm 720 Super rpm - low Heating High rpm 860 Low rpm 350 Super rpm - low Sound power level Cooling Nom. dba 60 62 Sound pressure level Cooling High dba 46 48 Heating High dba 47 48 Compressor Model YC23AEXDA Type Hermetically sealed swing compressor Output W 750 Operation range Cooling Ambien Min. ºCDB 0 t Max. ºCDB 46 Heating Ambien Min. ºCWB -5 t Max. ºCWB 20 Refrigerant Type R-40A Charge kg 0.74.0 Refrigerant oil Type FVC50K Charged volume l 0.375 Piping connections Drain ID mm - Piping length OU - IU Max. m 5 Level difference IU - IU Max. m 2 2-3 Electrical Specifications RX20JV RX25JV RX35JV Power supply Name V Phase ~ Frequency Hz 50 Voltage V 220-230-240 Current Nominal running Cooling A 2.52 3.52 5.02 current (RLA) Heating A 2.62 3.02 4.52 Starting current Cooling A 2.7 3.7 5.0 Heating A 2.7 3.7 5.0 Wiring connections For power supply Quantity 3 For connection with Quantity 4 indoor Remark Earth wire included 4 Split - Sky Air Outdoor Unit
Outdoor Unit RX-JV 3 Electrical data 3 - Electrical Data RX20-35J2VB Representative unit combination Power supply Comp OFM IFM Indoor unit Outdoor unit Hz-Volts Voltage range MCA MFA RHz RLA W FLA W FLA FTX20J2VB FTX25J2VB FTX35J2VB RX20J2VB RX25J2VB RX35J2VB 50-220 50-230 50-240 50-220 50-230 50-240 50-220 50-230 50-240 Max. 50Hz 264V Min. 50Hz 98V Max. 50Hz 264V Min. 50Hz 98V Max. 50Hz 264V Min. 50Hz 98V 4.5 6 36 2.2 33 0.7 6 0.2 4.5 6 48 3.2 33 0.7 6 0.2 4.5 6 70 4.7 33 0.7 6 0.2 3 3 SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz). RLA is based on the following conditions. Indoor temp. 27 C DB/9 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 3D0659 Split - Sky Air Outdoor Unit 5
4 Capacity tables Outdoor Unit RX-JV 4 - Cooling/Heating Capacity Tables 4 FTX20J2VB+RX20J2VB Cooling 50Hz 220-240V AFR 9. BF 0.24 Indoor Outdoor temperature ( C DB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 4.0 6.0 8.0 9.0 22.0 24.0 20 22 25 27 30 32 2.05 2.4 2.23 2.28 2.42 2.5.7.68.79.9.85.8 0.42 0.42 0.43 0.43 0.43 0.43.96 2.05 2.4 2.9 2.32 2.42.67.64.75.88.82.78 0.46 0.47 0.47 0.47 0.47 0.47.86.95 2.05 2.09 2.23 2.32.62.60.7.84.79.76 0.50 0.5 0.5 0.5 0.5 0.52.83.92 2.0 2.06 2.9 2.29.6.59.70.83.78.74 0.52 0.52 0.52 0.53 0.53 0.53.77.86.95 2.00 2.4 2.23.58.56.68.80.76.73 0.54 0.55 0.55 0.55 0.55 0.56.68.77.86.9 2.05 2.4.54.52.64.77.73.70 0.58 0.59 0.59 0.59 0.59 0.60 Heating 50Hz 220-240V AFR 9.4 Indoor Outdoor temperature ( C WB) EDB -0-5 0 6 0 C TC PI TC PI TC PI TC PI TC PI 5.0 20.0 22.0 24.0 25.0 27.0.68.60.56.53.5.48 0.50 0.5 0.52 0.52 0.53 0.53.97.88.84.8.79.76 0.52 0.54 0.54 0.55 0.55 0.56 2.25 2.6 2.3 2.09 2.07 2.04 0.55 0.56 0.57 0.57 0.57 0.58 2.59 2.50 2.47 2.43 2.4 2.38 0.58 0.59 0.60 0.60 0.60 0.6 2.8 2.73 2.69 2.66 2.64 2.6 0.60 0.6 0.6 0.62 0.62 0.63 SYMBOLS 3 /min.) BF : Bypass factor EWB : Entering wet bulb temp. ( C) EDB : Entering dry bulb temp. ( C) TC : Total capacity (kw) SHC : Sensible heat capacity (kw) PI : Power input (kw). Capacities are based on the following conditions. () Corresponding refrigerant piping length : 5m (2) Level difference : 0m 2. shows nominal (rated) capacities and power input 3D06592 FTX25J2VB+RX25J2VB Cooling 50Hz 220-240V AFR 9.2 BF 0.29 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 4.0 6.0 8.0 9.0 22.0 24.0 20 22 25 27 30 32 2.5 2.68 2.79 2.85 3.02 3.4.72.89.98 2.09 2.02.96 0.52 0.56 0.57 0.57 0.57 0.58 2.5 2.56 2.68 2.73 2.9 3.02.72.83.93 2.04.97.92 0.58 0.62 0.62 0.62 0.63 0.63 2.5 2.44 2.56 2.62 2.79 2.90.72.78.88.99.93.89 0.65 0.67 0.67 0.68 0.68 0.68 2.5 2.40 2.5 2.57 2.74 2.86.72.76.86.97.9.87 0.68 0.69 0.70 0.70 0.70 0.7 2.5 2.33 2.44 2.50 2.67 2.79.72.72.83.94.89.85 0.72 0.73 0.73 0.73 0.73 0.74 2.0 2.2 2.33 2.38 2.56 2.67.69.67.78.90.85.8 0.78 0.78 0.78 0.78 0.79 0.79 Heating 50Hz 220-240V AFR 9.7 Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 C TC PI TC PI TC PI TC PI TC PI 5.0.88 0.58 2.20 0.6 2.52 0.64 2.90 0.67 3.5 0.70 20.0.79 0.60 2.0 0.63 2.42 0.66 2.80 0.69 3.05 0.7 22.0 24.0 25.0 27.0.75.7.69.65 0.6 0.6 0.6 0.62 2.07 2.03 2.0.97 0.63 0.64 0.64 0.65 2.38 2.34 2.32 2.29 0.66 0.67 0.67 0.68 2.76 2.72 2.70 2.66 0.70 0.70 0.7 0.7 3.0 2.98 2.96 2.92 0.72 0.73 0.73 0.73 SYMBOLS 3 /min.) BF : Bypass factor EWB : Entering wet bulb temp. ( C) EDB : Entering dry bulb temp. ( C) TC : Total capacity (kw) SHC : Sensible heat capacity (kw) PI : Power input (kw). Capacities are based on the following conditions. () Corresponding refrigerant piping length : 5m (2) Level difference : 0m 2. show nominal (rated) capacities and power input 3D06594 6 Split - Sky Air Outdoor Unit
Outdoor Unit RX-JV 4 Capacity tables 4 - Cooling/Heating Capacity Tables FTX35J2VB+RX35J2VB Cooling 50Hz 220-240V 4.0 6.0 8.0 9.0 22.0 24.0 20 22 25 27 30 32 2.30 3.07 3.68 3.76 3.99 4.4.83 2. 2.43 2.54 2.45 2.38 0.72 0.75 0.76 0.76 0.77 0.77 2.30 3.07 3.53 3.6 3.84 3.99.83 2. 2.36 2.48 2.39 2.32 0.82 0.83 0.83 0.84 0.84 0.85 2.30 3.07 3.38 3.45 3.68 3.83.83 2. 2.29 2.4 2.32 2.26 0.90 0.90 0.9 0.9 0.9 0.92 AFR 9.3 BF 0.25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.30.83 0.97 3.07 2. 0.97 3.22 2.22 0.98 2.30 3.07 3.32 3.39 3.62 3.77.83 2. 2.26 2.38 2.30 2.24 0.93 0.93 0.93 0.94 0.94 0.95 3.30 2.34 0.98 3.53 3.68 2.27 2.2 0.99 0.99 2.30 2.92 3.07 3.5 3.37 3.53.83 2.04 2.5 2.27 2.2 2.6.04.05.05.05.06.06 3 4 Heating 50Hz 220-240V AFR 0. Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 C TC PI TC PI TC PI TC PI TC PI 5.0 2.36 0.79 2.75 0.82 3.5 0.86 3.62 0.9 3.94 0.94 20.0 2.24 0.8 2.63 0.85 3.03 0.88 3.50 0.93 3.82 0.96 22.0 24.0 25.0 27.0 2.9 2.4 2. 2.07 0.82 0.82 0.83 0.84 2.58 2.53 2.5 2.46 0.85 0.86 0.87 0.88 2.98 2.93 2.90 2.86 0.89 0.90 0.90 0.9 3.45 3.40 3.38 3.33 0.94 0.95 0.95 0.96 3.77 3.72 3.70 3.65 0.97 0.98 0.98 0.99 SYMBOLS 3 /min.) BF : Bypass factor EWB : Entering wet bulb temp. ( C) EDB : Entering dry bulb temp. ( C) TC : Total capacity (kw) SHC : Sensible heat capacity (kw) PI : Power input (kw). Capacities are based on the following conditions. () Corresponding refrigerant piping length : 5m (2) Level difference : 0m 2. shows nominal (rated) capacities and power input. 3D06595 Split - Sky Air Outdoor Unit 7
Outdoor Unit RX-JV 5 Dimensional drawings 5 - Dimensional Drawings 5 RX20-35J2VB Drain outlet ( I, D ø 5.9 hose for connection with drain joint [option] ) 4-holes for anchor bolts ( M8 or M0 ) MINIMUM SPACE FOR AIR PASSAGE Wall height on air outlet side = less than 200 Caution label Handle Brand name label Manufacture s label Outdoor air thermistor Wiring inlet Service port Liquid stop valve (ø 6.4 cut) In case of removing stop valve cover Gas stop valve (ø 9.5 cut) 3D058472A 8 Split - Sky Air Outdoor Unit
Outdoor Unit RX-JV 6 Centre of gravity 6 - Centre of Gravity RX20-25J2VB 3 6 4D058C RX35J2VB 4D05847C Split - Sky Air Outdoor Unit 9
7 Piping diagrams 7 - Piping Diagrams Outdoor Unit RX-JV RX20-25J2VB OUTDOOR UNIT 7 Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Discharge pipe thermistor ON: Heating Compressor Heating 3D05876B RX35J2VB OUTDOOR UNIT Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Discharge pipe thermistor Four way ON: Heating Compressor Heating 3D05874B 0 Split - Sky Air Outdoor Unit
Outdoor Unit RX-JV 8 Wiring diagrams 8 - Wiring Diagrams - Single Phase RX20-35J2VB 3 8 Split - Sky Air Outdoor Unit
9 Sound data Outdoor Unit RX-JV 9 - Sound Pressure Spectrum RX20J2VB Cooling Heating 9 Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 50Hz Scale 230v (H) Over All (db): (B,G,N is already rectified) A 46 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 m The operation noise measuring method is in accordance with JISC962 50Hz Scale 230v (H) Over All (db): (B,G,N is already rectified) A 47 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 m The operation noise measuring method is in accordance with JISC962 3D059002A RX25J2VB Cooling Heating Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 50Hz Scale 230v (H) Over All (db): (B,G,N is already rectified) A 46 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 m The operation noise measuring method is in accordance with JISC962 50Hz Scale 230v (H) Over All (db): (B,G,N is already rectified) A 47 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 m The operation noise measuring method is in accordance with JISC962 3D059003A 2 Split - Sky Air Outdoor Unit
Outdoor Unit RX-JV 9 Sound data 9 - Sound Pressure Spectrum RX35J2VB Cooling Heating 3 Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise 9 Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 The operation noise measuring method is in accordance with JISC962 50Hz Scale 230V (H) A 48 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. JISC962 The operation noise measuring method is in accordance with JISC962 50Hz Scale 230V (H) A 48 3D059004A Split - Sky Air Outdoor Unit 3
0 Operation range 0 - Operation Range Outdoor Unit RX-JV RX20-35J2VB Cooling 0 Outdoor temp. ( C DB) Continuous operation Pull-down period Outdoor temp. ( C WB) Continuous operation Indoor temp. ( C WB) (-5 C DB) The graphs are based on the following conditions. Equivalent piping length 5m Level difference 0m Indoor temp. ( C DB) 3D058975A 4 Split - Sky Air Outdoor Unit
Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. EEDEN 2-0 0 Please fill out the requested information Please fill out the requested information Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 042 20 336 - RPR Oostende EEDEN2-00 04/2 Copyright Daikin The present publication supersedes EEDEN-00 Printed on non-chlorinated paper. Prepared by Goekint Graphics NV, Belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende