AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE
|
|
|
- Joy Rogers
- 9 years ago
- Views:
Transcription
1 AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3)
2
3 Specifications in this manual are subject to change without notice in order that HITACHI may bring the latest innovations to their customers. Whilst every effort is made to ensure that all specifications are correct, printing errors are beyond Hitachi s control; Hitachi cannot be held responsible for these errors.
4
5 Content C o n t e n t Benefits of AquaFREE General data Dimensional Data Capacities and selection data Working Range Refrigerant Cycle Piping, Refrigerant and Water charge Electrical data Electrical wiring and setup Remote control switches Available optional functions Troubleshooting page
6
7 Content Content 1. Benefits of AquaFREE Benefits from the selection point of view Benefits from the point of view of the Installation Benefits from the startup point of view Benefits from the point of view of functionality Benefits from the point of view of maintenance Main features of the H(V)RNE outdoor units General data AquaFREE modules Outdoor Units Main Component Data for AquaFREE modules Main Component data for Outdoor Units Dimensions data AquaFREE modules Outdoor Units: RASDC Inverter Capacities and information for selecting unit Choosing your AquaFREE system Capacity in heating mode Capacity in cooling mode Capacities and electrical power consumed for the most significant values Correction factors for piping length Data related to noise Foundation Working range Power Supply Temperature Range Piping Provision Refrigerant cycle Refrigerant cycle between RWM and RAS page 7
8 Content Content (cont.) 7. Piping and water charge Range of refrigerant piping Amount of refrigerant charged Caution in case of refrigerant leakage Hydraulic circuit Electrical data AquaFREE module Outdoor Units Electrical wiring and setup General check Setting and function of DIP Switches for Outdoor Units Setting and function of DIP Switches for AquaFREE module Common Wiring Room Thermostat Operation Remote control switch Available optional functions Available optional functions for outdoor units Troubleshooting Alarm Code Indication of Remote Control Switch: Alarm codes page
9 Content MODELS CODIFICATION List of AquaFREE modules, outdoor units, and accessories available in this technical catalogue AquaFREE MODULES RWM AquaFREE (Basic Models) RWM AquaFREE (Models with electric resistance) Unit Indication Code Unit Indication Code Unit Indication Code RWM3FSN1E NEW RWM3FSN1E4.5H NEW RWM4FSN1E NEW RWM4FSN1E6H NEW RWM4FSN1E6H NEW RWM5FSN1E NEW RWM5FSN1E6H NEW RWM5FSN1E6H NEW RWM 1~ 1~ 3~ AquaFREE MODULES (*) RWM AquaFREE (Basic Models for swimming pool) RWM AquaFREE (Models for swimming pool with electric resistance) Unit Indication Code Unit Indication Code Unit Indication Code RWM3FSN1ES NEW RWM3FSN1ES14.5H NEW RWM4FSN1ES NEW RWM4FSN1ES16H NEW RWM4FSN1ES16H NEW RWM5FSN1ES NEW RWM5FSN1ES16H NEW RWM5FSN1ES16H NEW RWM 1~ 1~ 3~ (*) Next launching Unit Type (AquaFREE module) RWM RWM5FSN1ES16H1 Capacity (HP): Sistem: System Free Refrigerant: R410A Series E: Made in Europe Type : Swimming pool Power supply: 1~230V,50Hz 3~400V,50Hz Model with electric heater kw page 9
10 Content OUTDOOR UNITS Utopia DC Inverter Unit Indication Code Unit Indication Code Unit Indication Code RAS3HVRNE 7E RAS4HVRNE 7E RAS4HRNE 7E RAS5HVRNE 7E RAS5HRNE 7E RAS 1~ 3~ ACCESSORIES CODE LIST Accessory Name Indication Code Figure DBS26 Drain Discharging Boss NEW TTFSN1E Thermostatic Tank To be informed later page 10
11 Overview of the system I n t r o d u c t i o n : Overview of the System System Description HITACHI s AquaFREE system is a Heat pump Heating system for winter, and a partial cooling system for summer. The system consists of an Inverter Heat Pump outdoor unit and a hydraulic module indoor unit. The heat pump absorbs or sends heat to the outside, and transfers it to the water circuit by means of the AquaFREE module. The AquaFREE airconditioning system incorporates a set of technical benefits that make it one of the most attractive on the market. Right from the selection of the ideal type of equipment in each case, up to its maintenance, and through installation, start up and operation, AquaFREE always provides the best solution for every user, and greatly simplifies and eases the user s selection process. AquaFREE systems provide great comfort, high reliability, rigorous design, low electrical consumption, and a small installation space. The AquaFREE system is made up of the following units: H(V)RNE outdoor units with the following capacity: RAS(3~5)HVRNE RAS(4/5)HRNE AquaFREE modules with or without support resistance: RWM(3~5)FSN1E RWM(3~5)FSN1EH(1/3) AquaFREE modules for pool water heating applications, with or without support resistance RWM(3~5)FSN1ES1 RWM(3~5)FSN1ESH(1/3) Main features of the system. Types of Applications: Radiant floor, radiators, hybrid radiators + radiant floor systems, and pool heating applications. Large variety of AquaFREE modules with or without support resistance. Flexible installation, outdoor unit may be placed at a distance of up to 30m. page 11
12
13 Benefits of AquaFREE 1. B e n e f i t s o f A q u a F R E E This chapter describes the features and benefits of the new AquaFREE modules, which, thanks to the flexibility and modularity of its system will provide you with the complete solution for your air conditioning requirements. 1 Content 1. Benefits of AquaFREE Benefits from the selection point of view Environment friendly Selection Range Options and accessories Adaptable to the customer s needs Benefits from the point of view of the Installation Compact Size Long piping length Easy installation and maintenance Easy and flexible communication installation Benefits from the startup point of view Easy start up Service checking tool Benefits from the point of view of functionality Designed for maximum comfort Easy to use High efficiency system Wide range of temperatures Noise reduction Benefits from the point of view of maintenance High reliability Designed for easy maintenance Main features of the elements that make up the AquaFREE module Main features of the H(V)RNE outdoor units High efficiency cooling circuit Highly efficient scroll compressor...26 page 13
14
15 Benefits of AquaFREE 1. B e n e f i t s o f A q u a F R E E Selection Benefits: 1.1. Benefits from the selection point of view The AquaFREE system provides a series of technical benefits that make it more attractive to the user. These benefits are described in detail below: Environment friendly Uses R410A refrigerant Hitachi AquaFREE units are environment friendly since they use R410A refrigerant. R410 is totally ecological since it does not contain any substances that are harmful to the ozone layer, ODP=0. Highly efficient Hitachi AquaFREE units are very efficient and allow important energy savings compared to conventional systems; these energy savings also mean that less CO2, which causes the greenhouse effect, is produced. page 15 1
16 Benefits of AquaFREE. Selection Benefits: Selection Range Range of Outdoor units The range of the H(V)RNE outdoor unit series allows to select 3~5HP units, for single as well as three phase combinations. The H(V)RNE units are very efficient and silent. The combination of the scroll compressor and the inverter type continuous control allow a high level of efficiency as well as important noise reduction as compared to conventional units. Outdoor Units Capacity (HP) Outdoor unit UTOPIA DCINVERTER H(V)RNE AquaFREE module The range of AquaFREE modules allows to choose between a wide range of possibilities depending on the application chosen Single phase and three phase units, with or without electric heater as shown in the following table: Modules Capacity (HP) Indoor unit without electric heater AquaFREE Basic (1~) RWM FSN1E Indoor units with electric heater AquaFREE Electric heater Pool (3~) RWM FSN1ESH3 AquaFREE AquaFREE MODULE AquaFREE Electric heater (1~) RWM FSN1EH1 Electric heater Pool (1~) RWM FSN1ESH1 AquaFREE AquaFREE Basic Electric heater Pool (1~) (3~) RWM RWM FSN1ES1 FSN1EH3 page 16
17 Benefits of AquaFREE Selection Benefits: Main Features: AquaFREE units have minimal dimensions and low noise level Options and accessories The AquaFREE system have a series of options and accessories to improve the installation and make it more flexible depending on the required needs. Electric Heater They are support resistances that are used to increase the temperature of the water under very extreme outdoor conditions, such as low temperatures. They can be single or three phase. The adjustment of these resistances depends on the needs of each installation. The electric heater can operate independently of the compressor. Flexibility: Depending on the need of each installation, either of two operation modes can be selected by means of a simple jumper 1 Pool Module It includes an additional exchanger in order to use the AquaFREE system to heat the water of the pool. This exchanger can also include the support resistances module, single as well as three phase. Thermostatic Tank It s a hydraulic device that allows to automatically adjust the temperature of the water in order to work with different water temperatures. It s very useful for mixed radiators and radiant floor circuits Room Thermostat The Remote thermostat s features are as follows: Radio thermostat, wireless. Innovative and ergonomic design. Easy to handle, displayed on a large screen. Different working modes depending on room occupancy. Different programs for run, stop and timer operation. A very useful holidays mode. page 17
18 Benefits of AquaFREE. Selection Benefits: Adaptable to the customer s needs Selecting the most adequate system Depending on his needs, the user can choose between different systems: Systems for radiant floor Systems for radiators Mixed systems, radiators + radiant floor Systems to heat the water of a pool. Easy temperature selection The water temperature can be adjusted by means of a 10 position rotary switch. These 10 different position allow to optimize the installation depending on the needs of each installation. The set temperature can be up to 48ºC. The working temperature range for each of these 10 positions is shown in the following graph: Water Temperature Ambient temperature page 18
19 Benefits of AquaFREE Installation benefits: 1.2. Benefits from the point of view of the Installation As far as installation is concerned, AquaFREE systems provide the following benefits: Compact Size The AquaFREE module requires less installation space than a conventional boiler Long piping length Water piping The AquaFREE system is prepared for long lengths of hydraulic piping with a pressure loss of up to 0,5 bar. Gas piping Available in lengths of up to 30 meters, with a distance that allows to make the installation flexible depending on each user s needs. Length of up to 30 mts. page 19
20 Benefits of AquaFREE. Installation benefits: Easy installation and maintenance The use of electricity as the energy source instead of fossil fuels implies a series of benefits from the installation as well as the ulterior maintenance point of view. The benefits are the following: High efficiency Compact installation No accumulation tanks required for the energy source Conventional boiler Accumulator tank The AquaFREE module does not require an Accumulator Tank Easy and flexible communication installation No polarity The units of the system interconnect by means of the bus called HLink, which consists of two non polar wires and allows for distances of up to 1000 meters. Length of up to 1,000 mts. page 20
21 Benefits of AquaFREE Startup Benefits: 1.3. Benefits from the startup point of view As far as start up is concerned, AquaFREE systems provide the following benefits: Easy start up Selection switches Start up is performed by means of an intuitive system to select the different parameters that make up the AquaFREE module. Commissioning This selection is performed by means of rotary switches that configure the different basic parameters of the module: Set water temperatures, and adjustment of the Electric heater s working range. There are different startup and temperature adjustment conditions to adjust the support electric resistances. Each installation can be customized depending on the needs. 1 Liquid crystal display Indoor Unit Number Refrigerant Cycle Number Alarm Code RCRC Adjustable thermostat for the water temperature Model code Indicated for a second alternately No. of AquaFREE modules connected Example of Alarm 02 detection Alarm Code Alarm system Rigorous alarms detection system. The AquaFREE systems provide a wide range of alarms detection which impacts directly on the setup and ulterior maintenance of the installation, allowing to control all the key points of the unit by means of the PCP1HE. All the control parameters of all the key point of the systems cans be viewed with a simple check mode : inverter compressor frequency reading, thermistor temperature reading, etc. The PCP1HE is very useful for ulterior maintenance of the system and the units Service checking tool The liquid crystal display on the front part of the module will display an alarm code so that a diagnostic of the installation can be performed rapidly page 21
22 Benefits of AquaFREE. Functionality Benefits: 1.4. Benefits from the point of view of functionality Designed for maximum comfort. Hitachi s AquaFREE technology materializes into very functional machines, that are designed to provide maximum comfort to its users. An example of this are the new technologies used in the AquaFREE Series air conditioning systems One of these new technologies is the control of the system by means of a simple 10 position rotary switch located on one of the sides of the electrical box which allows to customize the set temperature of the water depending on each installation Easy to use. Very easy for the users to use, the complete operation of the unit can be controlled with only three buttons High efficiency system. Increase of the system s capacity AquaFREE systems are highly efficient, which is due to the following technical features: A more efficient heat exchanger. Gas injection circuit Reduced power consumption Highly Efficient DC Scroll Compressor Use of neodymium magnets in the rotor of the compressor motor. Use of the new inverter control. Highly Efficient DC Scroll Compressor page 22
23 Benefits of AquaFREE Functionality Benefits: Highlevel COP and EER. As an example of this high level, the capacity operation power (COP) and the energy efficiency ratio (EER) for the RAS3HVRNE unit are shown. Heating mode Refresh mode Wide range of temperatures. RANGE The use of the inverter systems along with the AquaFREE module implies a wide range of temperatures Temperature range for operation in radiant floor and radiators External Air temperature WaterTemperature Cooling operation (DW) Heating operation (WB) NOTE: DW : Dry Bulb WB : Wet Bulb page 23
24 Benefits of AquaFREE. Functionality Benefits: Noise reduction HITACHI AquaFREE systems have been designed to reduce noise to a minimum. The AquaFREE module has been desigend rigorously to reduce the installation s noise to 28 db (A). Because HITACHI has used all of the technology it disposes of for developing its products, AquaFREE is one of the most silent systems on the market. The compressor s features are as follows: Scroll type The use of neodymium magnets improves the performance at low frequencies. 2 parts rotor reduces electromagnetic noise. The fan s features are as follows: Uses DC motors DC motor Efficiency increased by 40%. (Motor input halved) Motor Efficiency (%) AC motor Revolutions per Min. (rpm) Control by means of PWM (pulse width modulation). This control system allows to control and adjust the fan s startup and stop rate Electricity Time 120 Current Voltage 180 Electricity Time 180 Current Voltage 180º RECTANGULAR WAVE PWM CONTROL By combining these elements the system s electromagnetic noises have been reduced. page 24
25 Benefits of AquaFREE Service Benefits: 1.5. Benefits from the point of view of maintenance High reliability Minimizes maintenance Faithful to Hitachi s usual philosophy, HITACHI AquaFREE units have been designed to guarantee great reliability and robustness in order to reduce maintenance operations to a minimum Designed for easy maintenance Easy accessibility All AquaFREE systems components are easily accessible. You ou ou can access all of the unit s components to perform appropriate operations through a simple cover. The entire system is designed for maintenance operations to be easy and simple. Monotubular Heat Exchanger 29 alarm codes for easy maintenance These units use up to 29 very precise alarm codes in order to rapidly locate any problem that might occur. These alarms are grouped by elements that belong to the system in order to facilitate maintenance work and optimize the installer s job Main features of the elements that make up the AquaFREE module Monotubular Heat Exchanger The monotubular exchanger has developed a very efficient exchanger system with a system of external fins and an internal system by slotted tube It allows easy disassembly for cleaning and maintenance work. It has a polyamide cover to avoid risks of corrosion. Expansion Tank Expansion Tank Stainless steel sanitary type expansion tank page 25
26 Benefits of AquaFREE. Main features of the H(V)RNE units: 1.6. Main features of the H(V)RNE outdoor units The RASH(V)RNE outdoor units are characterized by their silence and their efficiency; they were designed with very high technology High efficiency cooling circuit For the refrigerant cycle, HITACHI has developed a new and more efficient heat exchanger. New aluminum fins for the heat exchanger The new smaller flow resistance heat exchanger using new aluminium fins reduces resistance airflow and pressure loss in pipes. Air flow resistance decreased by 20%. The optimised slit shape minimises noise by reducing air intake resistance. Pressure drop in heat exchanger pipe has been decreased. Bigger heat exchanger The new bigger heat exchanger increases efficiency. A lower flow resistance provides more silent operation Highly efficient scroll compressor Hitachi s exclusive Scroll Compressor The strong points of the new Hitachi high pressure scroll compressor Improvement of the compressor shaft s rotation system, which has two bearings located on the ends of the shaft which allow for greater system reliability. New scroll coil which permits to optimize the overlap between the two scrolls, thus greatly reducing intake loss by leakage. Oil return circuit design largely reduces heat loss. Improved lubrication system to provide accurate oiling for the compressor. page 26
27 Benefits of AquaFREE Main features of the H(V)RNE units: Compressor control by means of an inverter regulation Control by inverter provides a very fine control of the compressor which allows to rapidly attain the set temperature and maintain a stable operation which saves energy and reduces the noise level. This operation is possible because the compressor operators continuously and autoregulates itself according to the system s needs. In this way, the energetic waste of the conventional systems when stopping and starting up when the set temperature is reached is not allowed. At the same time, possible compressor breakage is eliminated since many startups and stops are avoided. 1 Concept of Operation (in Heating Mode) Set temperature Water Temperature DC INVERTER Machine with constant speed Time page 27
28
29 General data 2. G e n e r a l d a t a This chapter contains a rapid description of the main data of AquaFREE modules and their complementary RAS H(V)RNE outdoor units of Hitachi s DC Inverter series. Content 2. General data AquaFREE modules RWM AquaFREE (Basic Models) RWM AquaFREE (Models with electric resistance) RWM AquaFREE (Basic Models for swimming pools) RWM AquaFREE (Models for swimming pools and with electric resistance) Outdoor Units RAS DC Inverter Main Component Data for AquaFREE modules RWM AquaFREE (Basic Models) RWM AquaFREE (Models with electric resistance) RWM AquaFREE (Basic Models for swimming pools) RWM AquaFREE (Models for swimming pools and with electric resistance) Main Component data for Outdoor Units RAS DC Inverter page 29
30 General data 2.1. AquaFREE modules RWM AquaFREE (Basic Models) RWM model RWM3FSN1E RWM4FSN1E RWM5FSN1E Electrical Power Supply 1~230V. 50Hz Cooling for radiant floor (Min/Nom/Max) kw 3.90/7.10/ /10.00/ /12.50/14.00 Conditions: (35ºC ext / 19ºC water) Energy efficiency rate (EER) Heating for radiant floor (Min/Nom/Max) kw 4.00/8.00/ /11.20/ /14.00/16.70 Conditions: (7ºC ext / 35ºC water) Coefficient of performance (COP) Pump Input power W Capacities Sound Pressure Level db(a) Outer Dimensions Height mm 900 Width mm 526 Depth mm 372 Net weight Kg Refrigerant R410A Refrigerant Piping Connection Connection with nuts mm Liquid Piping Ø9.53 (3/8 ) Connections size (inches) mm Gas pipe Ø15.88 (5/8 ) (inches) Water Pipe Connection Connection with nuts mm Circuit Ø25.4 (1 ) Connections size (inches) mm Supply Ø19.05 (3/4 ) (inches) Water Working pressure (Nom) maq Expansion vessel volume l 5 Maximum current power consumption A Packaging dimensions m Colour Aluminium Grey Remote Control SW CTA IMH RF A OD: Outer Diameter NOTE: 1. The nominal cooling and heating capacity is the combined capacity of HITACHI s AquaFree system, and it based with the following standards: Cooling capacity EN Heating capacity reverse cycle units EN 255 Operation conditions Cooling Heating Water Temperature Outdoor Air Inlet Temperature Inlet. 23,0 C 35.0 C Outlet 18,0 C 30.0 C DB 35,0 C 7,0 C WB 6,0 C 2. The Sound Pressure Level is based on following conditions: 1 meter from the unit s front surface. Voltage of the power source is 230V. The above data was measured in an anaechoic chamber so that reflected sound should be taken into consideration when installing the unit. Piping Length: 7.5 meters Piping lift: 0 meters DB: dry bulbwb: wet bulb page 30
31 General data RWM AquaFREE (Models with electric resistance) RWM model RWM3FSN1E 4.5H1 RWM4FSN1E 6H1 RWM5FSN1E 6H1 RWM4FSN1E 6H3 RWM5FSN1E 6H3 Electrical Power Supply 1~230V, 50 Hz 3~400V, 50 Hz Cooling for radiant floor (Min/Nom/Max) kw 3.90/7.10/ /10.00/ /12.50/ /10.00/ /12.50/14.00 Conditions: (35ºC ext / 19ºC water) Energy efficiency rate (EER) Heating for radiant floor (Min/Nom/Max) kw 4.00/8.00/ /11.20/ /14.00/ /11.20/ /14.00/16.70 Conditions: (7ºC ext / 35ºC water) Coefficient of performance (COP) 2 Auxiliary resistance at 230V kw 1.50/3.00/ kW (min/med/max) at 400V kw Auxiliary resistance at 230V kw 2.00/4.00/ /4.00/ kW (min/med/max) at 400V kw 2.00/4.00/ /4.00/6.00 Capacities Pump input power W Sound Pressure Level db(a) Outer Dimensions Height mm 900 Width mm 526 Depth mm 372 Net weight Kg Refrigerant R410A Refrigerant Piping Connection Connection with nuts mm Connections Liquid Piping Ø9.53 (3/8 ) (inches) size mm Gas pipe Ø15.88 (5/8 ) (inches) Water Pipe Connection Connection with nuts mm Connections Circuit Ø25.4 (1 ) (inches) size mm Supply Ø19.05 (3/4 ) (inches) Water Working pressure (Nom) maq Expansion vessel volume l 5 Maximum current power consumption A Packaging dimensions m Colour Aluminium Grey Remote Control SW CTA IMH RF A OD: Outer Diameter NOTE: 1. The nominal cooling and heating capacity is the combined capacity of HITACHI s AquaFree system, and it based with the following standards: Cooling capacity EN Heating capacity reverse cycle units EN 255 Operation conditions Cooling Heating Water Temperature Outdoor Air Inlet Temperature Inlet. 23,0 C 35.0 C Outlet 18,0 C 30.0 C DB 35,0 C 7,0 C WB 6,0 C 2. The Sound Pressure Level is based on following conditions: 1 meter from the unit s front surface. Voltage of the power source is 230V. The above data was measured in an anaechoic chamber so that reflected sound should be taken into consideration when installing the unit. Piping Length: 7.5 meters Piping lift: 0 meters DB: dry bulbwb: wet bulb page 31
32 General data RWM AquaFREE (Basic Models for swimming pools) RWM model RWM3FSN1ES1 RWM4FSN1ES1 RWM5FSN1ES1 Electrical Power Supply 1~230V, 50Hz Cooling for radiant floor (Min/Nom/Max) kw 3.90/7.10/ /10.00/ /12.50/14.00 Conditions: (35ºC ext / 19ºC water) Energy efficiency rate (EER) Heating for radiant floor (Min/Nom/Max) kw 4.00/8.00/ /11.20/ /14.00/16.70 Conditions: (7ºC ext / 35ºC water) Coefficient of performance (COP) Pump input power W Capacities Sound Pressure Level db(a) Outer Dimensions Height mm 900 Width mm 526 Depth mm 372 Net weight Kg Refrigerant R410A Refrigerant Piping Connection Connection with nuts mm Liquid Piping Ø9.53 (3/8 ) Connections size (inches) mm Gas pipe Ø15.88 (5/8 ) (inches) Water Pipe Connection Connection with nuts mm Circuit Ø25.4 (1 ) Connections size (inches) mm Supply Ø19.05 (3/4 ) (inches) Water Working pressure (Nom) maq Expansion vessel volume l 5 Maximum current power consumption A Packaging dimensions m Colour Aluminium Grey Remote Control SW CTA IMH RF A OD: Outer Diameter NOTE: 1. The nominal cooling and heating capacity is the combined capacity of HITACHI s AquaFree system, and it based with the following standards: Cooling capacity EN Heating capacity reverse cycle units EN 255 Operation conditions Cooling Heating Water Temperature Outdoor Air Inlet Temperature Inlet. 23,0 C 35.0 C Outlet 18,0 C 30.0 C DB 35,0 C 7,0 C WB 6,0 C 2. The Sound Pressure Level is based on following conditions: 1 meter from the unit s front surface. Voltage of the power source is 230V. The above data was measured in an anaechoic chamber so that reflected sound should be taken into consideration when installing the unit. Piping Length: 7.5 meters Piping lift: 0 meters DB: dry bulbwb: wet bulb page 32
33 General data RWM AquaFREE (Models for swimming pools and with electric resistance) RWM model RWM3FSN1E S14.5H1 RWM4FSN1E S16H1 RWM5FSN1E S16H1 RWM4FSN1E S16H3 RWM5FSN1E S16H3 Electrical Power Supply 1~230V, 50 Hz 3~400V, 50 Hz Cooling for radiant floor (Min/Nom/Max) kw 3.90/7.10/ /10.00/ /12.50/ /10.00/ /12.50/14.00 Conditions: (35ºC ext / 19ºC water) Energy efficiency rate (EER) Heating for radiant floor (Min/Nom/Max) kw 4.00/8.00/ /11.20/ /14.00/ /11.20/ /14.00/16.70 Conditions: (7ºC ext / 35ºC water) Coefficient of performance (COP) 2 Auxiliary resistance at 230V kw 1.50/3.00/ kW (min/med/max) at 400V kw Auxiliary resistance at 230V kw 2.00/4.00/ /4.00/ kW (min/med/max) at 400V kw 2.00/4.00/ /4.00/6.00 Capacities Pump input power W Sound Pressure Level db(a) Outer Dimensions Height mm 900 Width mm 526 Depth mm 372 Net weight Kg Refrigerant R410A Refrigerant Piping Connection Connection with nuts mm Connections Liquid Piping Ø9.53 (3/8 ) (inches) size mm Gas pipe Ø15.88 (5/8 ) (inches) Water Pipe Connection Connection with nuts mm Connections Circuit Ø25.4 (1 ) (inches) size mm Supply Ø19.05 (3/4 ) (inches) Water Working pressure (Nom) maq Expansion vessel volume l 5 Maximum current power consumption A Packaging dimensions m Colour Aluminium Grey Remote Control SW CTA IMH RF A OD: Outer Diameter NOTE: 1. The nominal cooling and heating capacity is the combined capacity of HITACHI s AquaFree system, and it based with the following standards: Cooling capacity EN Heating capacity reverse cycle units EN 255 Operation conditions Cooling Heating Water Temperature Outdoor Air Inlet Temperature Inlet. 23,0 C 35.0 C Outlet 18,0 C 30.0 C DB 35,0 C 7,0 C WB 6,0 C 2. The Sound Pressure Level is based on following conditions: 1 meter from the unit s front surface. Voltage of the power source is 230V. The above data was measured in an anaechoic chamber so that reflected sound should be taken into consideration when installing the unit. Piping Length: 7.5 meters Piping lift: 0 meters DB: dry bulbwb: wet bulb page 33
34 General data 2.2. Outdoor Units RAS DC Inverter RAS Model RAS3HVRNE RAS4HVRNE RAS5HVRNE RAS4HRNE RAS5HRNE Electrical power supply 1~230V, 50Hz 3~400V, 50Hz Colour (Munsell Code) Natural Grey (1.0Y8.5/0.5) Sound pressure level (night mode) db(a) 43 / (39) 45 / (41) 47 / (43) 45 / (41) 47 / (43) Sound power level db(a) Outer Dimensions Height mm Width mm Depth mm Net weight Kg Refrigerant R410A Flow control Micro processor Controlled Expansion Valve Type compressor Hermetic (Rotary) Hermetic (Scroll) Hermetic (Scroll) Hermetic (Scroll) Hermetic (Scroll) Heat exchanger Q ty Power kw MultiPass CrossFinned Tube Condenser Fan (Type) Propeller Fan Q ty Air Flow Rate m³/min Power W Refrigeration Piping Connection with nuts Connections Liquid Piping mm (inches) Ø9.53 (3/8 ) Ø9.53 (3/8 ) Ø9.53 (3/8 ) Ø9.53 (3/8 ) Ø9.53 (3/8 ) size mm Gas pipe (inches) Ø15.88 (5/8 ) Ø15.88 (5/8 ) Ø15.88 (5/8 ) Ø15.88 (5/8 ) Ø15.88 (5/8 ) Refrigerant charge Kg Maximum current power consumption A Packing Measurement m³ OD: Outer Diameter NOTE: 1. The nominal cooling and heating capacity is the combined capacity of HITACHI s AquaFree system, and it based with the following standards: Cooling capacity EN Heating capacity reverse cycle units EN 255 Operation conditions Cooling Heating Water Temperature Outdoor Air Inlet Temperature Inlet. 23,0 C 35.0 C Outlet 18,0 C 30.0 C DB 35,0 C 7,0 C WB 6,0 C 2. The Sound Pressure Level is based on following conditions: 1 meter from the unit s front surface. Voltage of the power source is 230V. The above data was measured in an anaechoic chamber so that reflected sound should be taken into consideration when installing the unit. Piping Length: 7.5 meters Piping lift: 0 meters DB: dry bulbwb: wet bulb page 34
35 General data 2.3. Main Component Data for AquaFREE modules The main components described are the following: AquaFREE modules: (WaterFree) Heat exchanger Water Pump Auxiliary resistance RWM AquaFREE (Basic Models) 2 RWM model RWM3FSN1E RWM4FSN1E RWM5FSN1E Heat exchanger Water pump Heat exchanger type Shell and Tube Material Copper tube / Plastic (PP) Rated exchanged capacity kw Piping Gas pipe Ø mm Liquid pipe Ø mm Water inlet Ø mm Water outlet Ø mm Maximum operating refrigerant pressure MPa Maximum operating water pressure MPa Cylinder diameter Ø mm Type RS6 RS6 RS7 Electrical power supply 1~230V, 50 Hz Expansion vessel Type Membrane surge tank Material Steel Volume l RWM AquaFREE (Models with electric resistance) Heat exchanger RWM model RWM3 FSN1E4.5H1 RWM4 FSN1E6H1 RWM5 FSN1E6H1 RWM4 FSN1E6H3 RWM5 FSN1E6H3 Heat exchanger type Shell and Tube Material Copper tube / Plastic (PP) Rated exchanged capacity kw Piping Gas pipe Ø mm Liquid pipe Ø mm Water inlet Ø mm Water outlet Ø mm Maximum operating refrigerant pressure MPa Maximum operating water pressure MPa Cilinder diameter Ø mm Water Pump Type RS7 RS7 RS7 RS7 RS7 Electrical power supply 1~230V. 50 Hz Expansion vessel Electric heater Type (manufactured / model) Membrane surge tank Material Steel Volume l 5 Type Electrical resistance Electrical resistance Electrical resistance Electrical resistance Electrical resistance Capacity kw page 35
36 General data RWM AquaFREE (Basic Models for swimming pools) RWM model RWM3FSN1ES1 RWM4FSN1ES1 RWM5FSN1ES1 Heat exchanger Water Pump Heat Exchanger Type Piping Material Outer Diameter Inlet gas (SAE) Inlet liquid (SAE) Water Inlet Water Outlet Maximum Operation Pressure Cilinder diameter Ø mm Ø mm Ø mm Ø mm Ø mm MPa Type (Manufactured / model) Electrical power supply Head pressure (Min/Max) Water flow (Min/Max) Expansion vessel Type (Manufactured / model) m maq m³/h Material To b e i n f o r m e d l a t e r RWM AquaFREE (Models for swimming pools and with electric resistance) RWM model Heat Exchanger Type RWM3 FSN1ES1 4.5H1 RWM4 FSN1ES1 6H1 RWM5 FSN1ES1 6H1 RWM4 FSN1ES1 6H3 RWM5 FSN1ES1 6H3 Material Heat exchanger Piping Outer Diameter Inlet gas (SAE) Inlet liquid (SAE) Water Inlet Water Outlet Ø mm Ø mm Ø mm Ø mm Ø mm To b e i n f o r m e d l a t e r Maximum Operation Pressure MPa Cilinder diameter m Water Pump Type (Manufactured / model) Electrical power supply Head pressure (Min/Max) Water flow (Min/Max) Expansion vessel Type (Manufactured / model) maq m³/h Material page 36
37 General data 2.4. Main Component data for Outdoor Units The main components described are the following: Outdoor Units: (DCInverter) Heat exchanger Fan Unit Compressor RAS DC Inverter 2 RAS Model RAS3 HVRNE RAS4 HVRNE RAS5 HVRNE RAS4 HRNE RAS5 HRNE Heat exchanger Fan Unit Compressor Heat Exchanger Type MultiPass CrossFinned Tube Material Copper Tube Piping Outer Diameter Ø mm Rows Number of Tubes/Coil qty Fins Material Aluminium Pitch mm 1,9 1,9 1,9 1,9 1,9 Maximum Operation Pressure MPa 4,15 4,15 4,15 4,15 4,15 Total Face Area m² 0,64 1,00 1,00 1,00 1,00 Number of Coils/Unit Type Propeller Fan Number/Unit qty Fan Outer Diameter mm Revolutions rpm Motor Nominal Air Flow/Fan m3/min Type DripProof Type Enclosure Starting method Permanent Condenser Horsepower W Q ty qty Insulation Class E E E E E Model 2YC45BXD Air Tight Pressure Motor Type E305AHD 27D4 E405AHD 36D2 E305AHD 27D4 E405HD36D4 Discharge MPa 4,15 4,15 4,15 4,15 4,15 Suction MPa 2,21 2,21 2,21 2,21 2,21 Starting method InverterDriven Poles qty Insulation Class E E E E E Type FVC50K FVC68D FVC68D FVC68D FVC68D Oil Q ty l 0,75 1,2 0,5 1,2 1,2 Refrigerant Charge Kg 2,4 3,6 3,6 3,6 3,6 page 37
38
39 Dimensional Data 3. D i m e n s i o n a l d a t a This chapter contains dimensional and minimum space required specifications to install AquaFREE and the complementary RAS H(V)RNE outdoor units of Hitachi s DC Inverter series. Content 3. Dimensions data AquaFREE modules Outdoor Units: RASDC Inverter page 39
40 Dimensional Data 3.1. AquaFREE modules RWM3~5FSN1E(S1)(4.5/6H1/3) View from A (Only for units without witout Electric resistances) 3D view of the RWM unit Installation space Units in: mm No. Description Remarks 1 Heat exchanger 2 Refrigerant Gas Line Flare nut connection Ø15.88 (5/8 ) 3 Refrigerant Liquid Line Flare nut connection Ø9.53 (3/8 ) 4 Expansion tank 5 Automatic drain 6 Safety valve 7 Front cover 8 Electrical Control Box 9 Water Pump 10 Electric resistance Ø19.05 (3/4 ) 11 Water connection Tamaño de las conexiones del circuito de agua del suelo 12 Water inlet from the RWM from the radiating floor radiante Ø25.4 (1 ) 13 Water outlet from the RWM to the radiating floor circuit 14 Electric Heater Only models (4.5/6H1/3) Drawing number: XEKS1053 page 40
41 Dimensional Data 3.2. Outdoor Units: RASDC Inverter RAS3HVRNE 3 Installation space Units in: mm No. Description Remarks 1 Service cover 2 Refrigerant Gas Line Flare nut: Ø Refrigerant Liquid Line Flare nut: Ø Holes for Refrigerant piping Knockout hole 5 Holes for Control Line Wiring Ø26.5 Knockout hole 6 Drain holes Ø26 7 Drain holes 4Ø24 8 Holes for Power Source Wiring Ø26.5 Knockout hole 9 Holes for fixing machine to floor 2 U Cut Holes 10 Holes for fixing machine to wall M5 selftapping screws NOTE: Even if there are no walls in front of or behind the unit, a minimum space of 600mm is required in front of the unit, and 200mm behind it. If there are walls around the unit, then vent holes must be made through the wall. When there are obstacles above the unit, the four surrounding sides must be kept open. Drawing number XEKS0831 page 41
42 Dimensional Data RAS4/5H(V)RNE Installation space Units in: mm No. Description Remarks 1 Service cover 2 Refrigerant Gas Line Flare nut: Ø Refrigerant Liquid Line Flare nut: Ø Holes for Refrigerant piping Knockout hole 5 Holes for Control Line Wiring Ø26.5 Knockout hole 6 Drain holes Ø26 7 Drain holes 4Ø24 8 Holes for Power Source Wiring Ø26.5 Knockout hole 9 Holes for fixing machine to floor 2 U Cut Holes 10 Holes for fixing machine to wall M5 selftapping screws NOTE: Even if there are no walls in front of or behind the unit, a minimum space of 600mm is required in front of the unit, and 300mm behind it. If there are walls around the unit, then vent holes must be made through the wall. When there are obstacles above the unit, the four surrounding sides must be kept open. Drawing number XEKS0831 page 42
43 Capacities and information for selecting the right unit 4.C a p a c i t i e s a n d i n f o r m a t i o n f o r s e l e c t i n g u n i t This chapter is a guide for selecting the unit best suited to your needs and shows performance details for each unit. Content 4. Capacities and information for selecting unit Choosing your AquaFREE system How to use the data in this chapter Example of choosing units by heating load Capacities available for cooling load Capacity in heating mode Capacity in cooling mode Capacities and electrical power consumed for the most significant values Heating mode Cooling mode Correction factors for piping length Data related to noise Foundation pag. 43
44 Capacities and information for selecting the right unit 4.1. Choosing your AquaFREE system The following steps are an example of how to choose the system units and indicates the way to decide on the model best suited to your own specific needs: We recommend that you choose the AquaFREE system according to the heating load How to use the data in this chapter Define the installation requirements: load, operating temperature and special installation needs. Then select the most suitable units. Decide on where to put the outdoor unit to allow easy maintenance and service. Use the following information to calculate the most suitable units: Relevant sections of Chapter 4: Unit capacities: Section 4.2 Correction factors for piping lenght: Section 4.6 Data related to noise: Section 4.7 In addition, use the following information from the technical catalogue: General data: Chapter 2 Length of water piping: Section Electrical water rule wiring: Section Example of choosing units by heating load We suggest the following method to determine the characteristics of the system units: System requirements Step 1: Heating load: Wetbulb temperature of the incoming air: 5 ºC Temperature of the water outlet: 35 ºC Temperature of the water inlet: 30 ºC Thermal load: 8.00 kw NOTE: The calculation methods for thermal loads in the building should comply with the regulations applicable in each country. Type of installation: Installation restrictions: Power source: AquaFREE module lower than the outdoor unit: Total equivalent distance between the AquaFREE module and the outdoor unit: Radiant Floorr 230 V, 1~, 50 Hz 15 m 20 m Type of AquaFREE module: AquaFREE RWM modules needed pag. 44
45 Capacities and information for selecting the right unit Step 2: Select the units Select the units to make up the AquaFREE system according to the thermal load needed. The system chosen should have a load capacity greater than the thermal load required by the installation. Use sections 4.2 and 4.3 to calculate your choice Unit chosen: The total heating load is 8.00 kw, and the choice of system depends on the table of capacities (section 4.2) for radiant floor (35/30ºC) Radiant floor Table 1: Heating capacity data: AquaFREE UNITS Outdoor air inlet temperature WB (ºC) Water outlet/inlet temperature (35/30ºC) Max. CAP 6 8,80 4 RWM4FSN1E 5 9,00 3 9,00 Apply a correction factor according to the length and height of the piping (section 4.7) and the heating capacity given in Table 1: NOTE: The defrosting factor is included in Table 1. Heating capacity of the system = heating capacity x correction factor for tubing length = 9.00 x 0.99 = 8.91 kw The AquaFREE system most suitable for your requirements is: Unit chosen RAS4HVRNE/RWM4FSN1E pag. 45
46 Capacities and information for selecting the right unit Step 3: Choose units with electrical resistance (heating load) Wetbulb temperature of the incoming air: 11 ºC Temperature of the water outlet: 35 ºC Temperature of the water inlet: 30 ºC Thermal load: kw Type of installation: Radiant floor Installation restrictions: Power source: AquaFREE module lower than the outdoor unit: Total equivalent distance between the AquaFREE module and the outdoor unit: Total heating load: 230 V, 1~, 50 Hz 15 m 20 m kw The total heating load is kw, and the choice of system depends on the table of capacities (section 4.2) for radiant floor (35/30ºC) Table 2: Heating capacity data AquaFREE units Outdoor air inlet temperature WB (ºC) Radiant Floor Water outlet/inlet temperature (35/30ºC) Max. CAP 9 8,30 RWM4FSN1E 11 8, ,60 NOTE: We advise using support heaters rather than overburdening the selected unit. As can be seen, the Total heating load > Capacity of the unit. These conditions require the use of additional electrical elements. The capacity of the electrical elements required can be checked in Chapter 2 (General Data). Select the available unit from the table in Chapter 2 (General Data) with the electrical element corresponding to model RWM4FSN1E6H1, with a total power of (8 x 0.99) + 6 kw of electrical resistance. Unit with selected electrical element. RWM4FSN1E6H1 pag. 46
47 Capacities and information for selecting the right unit Step 4: Choice of units for installations with radiators or mixed installations (radiators + radiant floor) In the case of installations with radiators, use the same process as the radiant floor method. Choose the values in the table of water outlet/inlet temperature (45/40ºC) For mixed installations, use the graphs corresponding to the radiator installations. Cooling load: Capacities available for cooling load The AquaFREE systems are limited cooling systems, not air conditioning. However, the temperature of a room can be reduced with water temperatures of between 19 and 21 ºC. The parameter which determines which temperature can be chosen is humidity. For areas with a high humidity, 21 ºC is recommended, while in the case of dry areas up to 19 ºC is possible. 4 pag. 47
48 Capacities and information for selecting the right unit 4.2 Capacity in heating mode The following tables show the heating capacity corresponding to a particular outdoor temperature, and with a water outlet/inlet temperature of 35/30 ºC and 45/40 ºC. Temperatures of between 35/30 ºC are recommended for radiant floor. Temperatures of between 45/40 ºC are recommended for lowintensity radiators. AquaFREE UNITS Outdoor air inlet temperature WB (ºC) Water outlet/inlet temperature (35/30ºC) Max. CAP Water outlet/inlet temperature (45/40 ºC) Max. CAP Radiant floor Radiators RWM3FSN1E RWM4FSN1E ,50 3, ,90 4, ,30 4,60 9 5,70 5,00 7 6,00 5,30 6 6,20 5,60 5 6,40 5,80 3 6,50 6,10 2 6,80 6,40 0 7,40 7,00 2 8,10 7,80 4 9,00 8, ,00 9, ,90 10, ,60 11, ,20 12, ,20 13, ,50 13, ,20 6, ,80 6, ,20 7, ,60 7, ,00 7,90 9 8,30 8,40 7 8,60 8,70 6 8,80 8,90 5 9,00 9,00 3 9,00 8,90 2 9,20 9,10 0 9,70 9, ,50 10, ,60 11, ,70 12, ,90 13, ,50 14, ,20 15, ,20 15, ,50 16,20 pag. 48
49 Capacities and information for selecting the right unit AquaFREE UNITS Outdoor air inlet temperature WB (ºC) Water outlet/inlet temperature (35/30ºC) Max. CAP Water outlet/inlet temperature (45/40 ºC) Max. CAP RWM5FSN1E Radiant floor Radiators 20 9,50 8, ,10 8, ,50 9, ,90 9, ,30 9, ,80 10, ,00 10, ,10 10, ,20 10, ,80 10, ,90 10, ,30 11, ,10 12, ,20 13, ,40 14, ,70 15, ,30 16, ,80 17, ,70 17, ,90 18,20 4 NOTES: Max. CAP: Compressor capacity at maximum frequency (kw) The correction factor for defrosting is included. pag. 49
50 Capacities and information for selecting the right unit Water outlet/inlet temperature (35/30 ºC) 26,0 25,0 24,0 23,0 22,0 21,0 20,0 RWM5FSN1E 19,0 18,0 17,0 RWM4FSN1E 16,0 Capacity (kw) Capacity (kw) 15,0 14,0 13,0 12,0 11,0 10,0 9,0 RWM3FSN1E* 8,0 7,0 6,0 5,0 4,0 3,0 2,0 1,0 0, Outdoor temperature (ºC) (WB) Water outlet/inlet temperature (45/30 ºC) 26,0 25,0 24,0 23,0 22,0 21,0 20,0 RWM5FSN1E 19,0 18,0 17,0 RWM4FSN1E 16,0 Capacity (kw) 15,0 14,0 13,0 12,0 11,0 10,0 RWM3FSN1E* 9,0 8,0 7,0 6,0 5,0 4,0 3,0 2,0 1,0 0, Outdoor temperature (ºC) (WB) NOTES: Compressor capacity at maximum frequency (kw) The correction factor for defrosting is included. pag. 50
51 Capacities and information for selecting the right unit 4.3 Capacity in cooling mode The following tables show the cooling capacity for specific outdoor temperatures, and with a water outlet/inlet temperature of 23/18 ºC. AquaFREE UNITS RWM3FSN1E RWM4FSN1E RWM5FSN1E Outdoor air inlet temperature DB (ºC) Water outlet/inlet temperature (18/23 ºC) Max. CAP Radiant floor 15 8, , , , , , , , , , , , , , , , , , , , ,40 4 NOTES: Max. CAP: Compressor capacity at maximum frequency (kw) Water outlet/inlet temperature (18/23 ºC) Capacity (kw) RWM5FSN1E RWM4FSN1E RWM3FSN1E Outdoor temperature (ºC) (DB) NOTE: Compressor capacity at maximum frequency (kw) pag. 51
52 Capacities and information for selecting the right unit 4.4. Capacities and electrical power consumed for the most significant values Heating mode AquaFREE units Outdoor air inlet temperature DB/WB (ºC) Water outlet/inlet temperature (35/30 ºC) Water outlet/inlet temperature (45/40 ºC) CAP IPT CAP IPT Radiant floor Radiators RWM3FSN1E 8,00 1,98 7,47 2,47 RWM4FSN1E 7/6 11,20 3,24 10,10 3,78 RWM5FSN1E 14,00 4,03 14,10 4,83 NOTES: CAP: Compressor capacity at nominal frequency (kw) IPT: Nominal electrical power consumed (kw) AquaFREE units Outdoor air inlet temperature WB (ºC) Water outlet/inlet temperature (35/30 ºC) Water outlet/inlet temperature (45/40 ºC) Max. CAP Max. IPT Max. CAP Max. IPT Radiant floor Radiators RWM3FSN1E 6,00 2,74 5,30 3,06 RWM4FSN1E 7 8,60 3,79 8,70 4,46 RWM5FSN1E 12,02 5,34 10,59 5,85 NOTES: Max. CAP: Compressor capacity at maximum frequency (kw) Max. IPT: Maximum electrical power consumed (kw) pag. 52
53 Capacities and information for selecting the right unit Cooling mode Water outlet/inlet temperature (19/24 ºC) AquaFREE UNITS Outdoor air inlet temperature DB (ºC) Max. CAP Max. IPT Radiant floor RWM3FSN1E 7,10 2,02 RWM4FSN1E 35 10,00 3,10 NOTES: Max. CAP: Compressor capacity at maximum frequency (kw) Max. IPT: Maximum electrical power consumed (kw) RWM5FSN1E 12,50 3, Correction factors for piping length The correction factor is based on the equivalent length of tubing in metres (EL) and the height between the AquaFREE module and the outside unit, also in metres (H). Outdoor unit on the roof AquaFREE module on the ground H: Height between the AquaFREE module and the outdoor unit (m). H>0: The outdoor unit is located above the AquaFREE module (m). H<0: The outdoor unit is located below the AquaFREE module (m). L: The real length of tubing in one direction between the AquaFREE module and the outdoor unit (m). AquaFREE module on the ground Outdoor unit in the basement The: Equivalent length of tubing in one direction between the AquaFREE module and the outdoor unit (m). NOTES: Use the following equivalences to calculate the equivalent length of tubing: An angle of 90º is equivalent to 0.5 m. An angle of 180º is equivalent to 1.5 m. pag. 53
54 Capacities and information for selecting the right unit Cooling capacity RAS3HVRNE Cooling Cooling capacity: The cooling capacity should be corrected using the following formula: RAS4H(V)RNE TCA = TC x F TCA: Real corrected cooling capacity (kw). TC: Cooling capacity from the table of cooling capacities (kw). F: Correction factor based on the equivalent length of tubing (%). Cooling RAS5H(V)RNE Cooling pag. 54
55 Capacities and information for selecting the right unit RAS3HVRNE Heating Heating capacity: The heating capacity should be corrected using the following formula: THA = TH x F THA: Real corrected heating capacity (kw). TH: Heating capacity from the table of heating capacities (kw). F: Correction factor based on the equivalent length of tubing (%) Heating RAS4H(V)RNE 4 RAS5H(V)RNE Heating pag. 55
56 Capacities and information for selecting the right unit 4.6. Data related to noise Model: RAS3HVRNE Power source: 230 V 50 Hz Model: RAS4H(V)RNE Power source: 230 V 50 Hz Point of measurement: 1 metre from the front surface 1.5 metres from ground level Acoustic criteria curve Point of measurement: 1 metre from the front surface 1.5 metres from ground level Acoustic criteria curve Nominal / Night shift: 43/39 db(a) Nominal / Night shift: 4/1 45/51 db(a) Acoustic pressure level (db measured using C scale ) Acoustic pressure level (db measured using C scale ) approximate continuous sound detection threshold approximate continuous sound detection threshold Frequency (Hz) Frequency (Hz) Model: RAS5H(V)RNE Point of measurement: Power source: 230 V 50 Hz 1 metre from the front surface 1.5 metres from ground level Acoustic criteria curve Nominal / Night shift: 47/43 db(a) Acoustic pressure level (db measured using C scale ) approximate continuous sound detection threshold pag. 56
57 Capacities and information for selecting the right unit Frequency (Hz) 4.7. Foundation Concrete foundations Cut this part of the bolt. Otherwise it will be difficult to remove the service cap. Mortar hole (ø 100 mm x 150 mm deep) antivibration rubber Drainage Drainage (100 mm wide x 200 mm deep) 4 A M10 anchoring bolt Fix the unit to the wall Hanging unit Rubber mat (*) Wall support (*) B Anchoring bolts (*) (*) Supplied by the installer MODEL A B RAS3HVRNE RAS 4/5H(V)RNE Units: mm pag. 57
58 Capacities and information for selecting the right unit pag. 58
59 Working Range 5. W o r k i n g r a n g e This chapter shows the working range of the new AquaFREE units and the complementary RASH(V)RNE outdoor units of Hitachi s DC Inverter series. Content 5. Working range Power Supply Temperature Range Piping Provision page 59
60 Working Range 5.1. Power Supply. Operating voltage Voltage Imbalance Starting Voltage 90% to 110% of the Rated Voltage Within a 3% Deviation from Each Voltage at the Main Terminal of Outdoor Unit Higher than 85% of the Rated Voltage Following the Council Directive 89/336/EEC and its amendments 92/31/EEC and 93/68/ EEC, relating to electromagnetic compatibility, next table indicates maximum permissible system impedance Z max at the interface point of the user s supply, in accordance with EN MODEL Z máx (Ω) RAS3HVRNE 0,35 RAS4HVRNE 0,27 RAS5HVRNE 0,26 RWM3FSN1E4.5H1 0,38 RWM4FSN1E6H1 0,29 RWM5FSN1E6H1 0, Temperature Range The temperature range is indicated in the following table. Cooling Operation Heating Operation Water Outlet Temperature Outdoor Temperature (*) 3HP = 15ºC WB Minimum 18 C 20 C Maximum 25 C 40 ºC Radiant floor 48 C Radiators Minimum 15 C DB 20 C WB (*) Maximum 43 C DB 15 C WB Cooling Operation Heating Operation Outdoor Air Temperature ( C DB) Outdoor Air Temperature ( C WB) Water Outlet Temperature ( C WB) Water Outlet Temperature ( C WB) Model RAS3HVRNE RAS4/5H(V)RNE Temperature (A) 15 ºC WB 20 ºC WB 5.3. Piping Provision Unit Power 3HP 4HP 5HP Maximum Piping Length L: Real length Equivalent length Maximum Piping Lift H: Outdoor Unit located higher than Indoor Unit 30 Outdoor Unit located higher than Indoor Unit 20 page 60
61 Refrigerant Cycle 6. R e f r i g e r a n t c y c l e This chapter contains the cycle diagrams of each type of installation of AquaFREE indoor units and RASH(V)RNE outdoor units of Hitachi s DC Inverter series. Content 6. Refrigerant cycle Refrigerant cycle between RWM and RAS The RWM unit is connected to a Floor heating or Radiators system The RWM unit is connected to a Floor heating and Radiators system page 61
62 Refrigerant Cycle 6.1. Refrigerant cycle between RWM and RAS The RWM unit is connected to a Floor heating or Radiators system Refrigerant Flow for Cooling Refrigerant Flow for Heating FieldSupplied Refrigerant Piping Connection with flare nut Flange Connection Brazing Connection Water Flow direction Refrigerant : R410A Airtight Test Pressure 4.15 MPa N Name of item N Name of item N Name of item 1 Compressor 11 Liquid Stop Valve 21 Water Pump 2 Heat exchanger 12 Pressure switch 22 Water low flow switch 3 Reciver 13 Filter 5/8 23 RWM water outlet 4 Expansion valve 14 Check valve 24 RWM water inlet 5 4Way valve 15 Solenoid valve 25 Water port connection 6 Filter 3/8 16 Heat exchanger 26 Water cut Pressure swith 7 Distributor 17 Expansion tank 27 Manometer 8 Check Joint 18 Air purger 28 9 Pressure switch 19 Electric heater (Only for H units) 10 Gas Stop Valve 20 Water cut Pressure swith 29 Security thermostat for electric heater. (Only for H units) Setting thermostat for the maximum water temperature. page 62
63 Refrigerant Cycle The RWM unit is connected to a Floor heating and Radiators system 6 Refrigerant Flow for Cooling Refrigerant Flow for Heating FieldSupplied Refrigerant Piping Connection with flare nut Flange Connection Brazing Connection Water Flow direction Refrigerant : R410A Airtight Test Pressure 4.15 MPa N Name of item N Name of item N Name of item 1 Compressor 11 Liquid Stop Valve 21 Water Pump 2 Heat exchanger 12 Pressure switch 22 Water low flow switch 3 Reciver 13 Filter 5/8 23 RWM water outlet 4 Expansion valve 14 Check valve 24 RWM water inlet 5 4Way valve 15 Solenoid valve 25 Water port connection 6 Filter 3/8 16 Heat exchanger 26 Water cut Pressure swith 7 Distributor 17 Expansion tank 27 Manometer 8 Check Joint 18 Air purger 28 9 Pressure switch 19 Electric heater (Only for H units) 10 Gas Stop Valve 20 Water cut Pressure swith 30 Branch pipe 29 Security thermostat for electric heater. (Only for H units) Setting thermostat for the maximum water temperature. page 63
64
65 Piping, refrigerant and water charge. 7. P i p i n g a n d w a t e r c h a r g e This chapter describes the refrigerant piping and water piping connections, and how to change the amount of water in an AquaFREE modul / Outdoor unit DC Inverter. Content 7. Piping and water charge Range of refrigerant piping Refrigerant Piping Length Refrigerant piping selection Amount of refrigerant charged Caution in case of refrigerant leakage Maximum permissible concentration of HCFC Gas Calculation of Refrigerant Concentration Countermeasure in case of refrigerant leakage according to the KHK Standard Hydraulic circuit Installation procedure Water piping length procedure Selecting the water piping page 65
66 Piping, refrigerant and water charge Range of refrigerant piping The piping selection and distribution must be designed considering the following specifications. Remember that the maximum pipe length is 30 m. NOTES: Description Item Mark Maximum applicable range OU: Outdoor unit AM: AquaFREE module Total length from the OU to the AM 30 m Height difference (Hio) between OU and AM Hio 30 m Height difference (Hio) between AM and OU Hio 20 m Refrigerant Piping Length The refrigerant piping between the AquaFREE module and the Outdoor Unit should be designed using the following chart. Keep the design point within the dark area of the chart, which shows the applicable height difference according to piping length NOTES: If the length of the piping is less than 5 m contact your Hitachi distributor. When the outdoor unit is installed at a higher level than the AquaFREE module Total length Height difference between the (m) outdoor unit and the AquaFREE module L (m) When the outdoor unit is installed at a lower level than the AquaFREE module 30m Maximum length of refrigerant piping Actual piping length 30 m Equivalent piping length 40 m page 66
67 Piping, refrigerant and water charge Refrigerant piping selection Select piping sizes according to the following values: Outdoor unit Pipe size Series (HP) Gas pipe Thickness (mm) Liquid Piping Thickness (mm) (5/8) (3/8) 0.80 H(V)RNE (5/8) (3/8) (5/8) (3/8) 0.80 Select the pipe size with adequate thickness and material, and with enough pressure. CAUTION: When charging refrigerant accurately measure refrigerant to be charged. Overcharging or undercharging of refrigerant can cause compressor trouble Amount of refrigerant charged The amount of refrigerant charged at factory allows to install up 30 m of piping. It is not necessary to add additional Refrigerant charge. Outdoor Unit Model Kg RAS3HVRNE 2.4 RAS4H(V)RNE 3.6 RAS5H(V)RNE Caution in case of refrigerant leakage Installers and installation designers are responsible for complying with local codes and regulations which specify safety requirements against refrigerant leakage Maximum permissible concentration of HCFC Gas Refrigerant R410A, which is charged in the AQUA FREE system, is an incombustible nontoxic gas. However, if leakage occurs and the gas fills a room, the gas may cause suffocation. The maximum permissible concentration of HCFC R410A in the air is 0,44 kg/m³, according to the refrigeration and air conditioning facility standard (KHK S 0010) of the High Pressure Gas Protection Association (KHK) from Japan. Therefore, some effective measure must be taken to lower the R410A concentration in air below 0,44 kg/m³, in case of leakage. page 67
68 Height 2.5 m Piping, refrigerant and water charge Calculation of Refrigerant Concentration 1. Calculate the total quantity of refrigerant R (kg) charged in the system connecting the AquaFREE module of the room to be airconditioned. 2. Calculate the volume V (m³) of each room. 3 Calculate the refrigerant concentration C (kg/m³) of the room according to the following equation: R = C V R: Total quantity of charged refrigerant (kg) V: Room volume (m³) C: refrigerant concentration ( 0,44* kg/m³ for R410A) Outdoor Unit (RAS5HVRNE) Refrigerant: 3.6 Kg Floor NOTE: 10 m 2 (*) Use this value only for reference because this value is not fixed. Fan m 3 /min (*) Gas leak detector (*) Opening: 0.06 m 2 (*) (*)These conditions occur whenever the concentration (c) exceeds the established limit. Room R (kg) V (m³) C (kg/m³) Countermeasure A 3,6 25 0, Countermeasure in case of refrigerant leakage according to the KHK Standard The facility must be layed out according to to the KHK standards, so that the refrigerant concentration will be below 0.44 kg/m³. 1. Provide a shutterless opening that will allow the fresh air to circulate into the room. 2. Provide a doorless opening with a size at least 0.15% of the floor area. 3 Provide a fan, connected to a gas leak detector, with a ventilating capacity of at least 0.5 m³/min per Japanese Refrigeration Ton (=compressor displacement 8.5 m³/h) of the air conditioning system utilizing refrigerant. 4. Pay special attention to the location, such as a basement,etc., where refrigerant can stagnate, since refrigerant is heavier than air. page 68
69 Piping, refrigerant and water charge Hydraulic circuit Installation procedure Piping connection 1. Connect the water piping to the AquaFREE module. CAUTION: When connecting the water piping to the indoor unit, is necessay install 500mm of flexible water piping from the indoor unit, in order to avoid metal expansion problems due to temperature. After these 500mm install copper Piping. Flexible water piping. Water inlet supply circuit (Field supplied) Flexible water piping. Copper water piping NOTE: The maximum piping lenght depends on the maximum pressure availability in the water oulet pipe. Please check the pump curves. NOTES: Selected enough space to connect the pipes in some space that there is enough operation space. It is recomended to use the flexible joints for the piping inlet and outlet, to avoid the transmission vibrations. It is recomended cover the water pipes with insolutacion for dew problems. Before the comissioning is necessary to clean the hydralic pipes using water. After cleaning the hydraulic system fill in the circuit. It is recommended install a filter of 1000 цm before water inlet connection pipe. 2. Install two valves. One at the water inlet pipe, and other at the water outlet pipe. System safety valves Filter 3. It is recommended to install a filter at the water inlet piping. 7 page 69
70 Piping, refrigerant and water charge. Piping connection 1. Install a check valve and flexible tube at inlet power supply. CAUTION: The quality of the water that you need is the standard water without any material that can cause damage inside the piping system. NOTE: In case that the Water piping would be located in a higher position than AquaFREE air purger, it is necessary to add an auxiliary purger system in the highest position of water piping installation. During the system water filling, it must be not purgue air system, at the same time. When a system refilling is performed, please check that general water pressure is higher than main water pressure Water supply connection. Size (3/4 ) Check valve Water mains CAUTION: In case of circuit refilling, takes mesures to prevent backsiphonage of non potable water into the water main. 2. Charge the system with water by introducing it through the filling valve. The nominal pressure of the water of the system must be (1.7~2.0) bar. (Recommended 1.8 bar). Water pressure in the circuit must be between 1 and 3 bar. 3. The system has got two safety devices: One low pressure switch. One relief valve page 70
71 Piping, refrigerant and water charge. 4 Install the drain pipe from the automatic drain valve until the general drain system. This securety drain valve will be activated when water pressure arrivest o 3 bars. NOTE: Install the unit in area that does not affect other elements if the drain valve blowoff. Circuit drain Water piping length procedure Pump range procedure In order to control the water flow rate you must lower the water pressure. The value of this pressure is calculated from the difference between the value of the inlet and outlet water pressure. Two pressure gauges must be installed in order to obtain this value: 1. Located after the pump (at the water outlet toward the radiating floor circuit) 2. Located over the water inlet port (as shown in the following figure). 7 NOTES: It is recommended to cover the water piping with insulation to avoid problems caused by moisture. NOTE: The second manometer is only necesary for comissioning. After this you can turn off The value of the water s pressure drop must be between the minimal and maximal values of the range of the water flow ratio curve. page 71
72 Piping, refrigerant and water charge. Curves of the pump The values of the water pressure must be within the range of the pressure pump. RWM3FSN1E (S1) RWM3FSN1E (S1) 4.5H1 Pressure pump range (mh 2 o) Pressure pump range (mh 2 o) RWM4FSN1E (S1) RWM4FSN1E (S1) 6H3 Pressure pump range (mh 2 o) Pressure pump range (mh 2 o) RWM5FSN1E (S1) RWM5FSN1E (S1) 6H3 Pressure pump range (mh 2 o) Pressure pump range (mh 2 o) Max. speed Med. speed Nominal Heating water flow page 72
73 Piping, refrigerant and water charge Selecting the water piping Select piping sizes for the connection according to the following values: Diameter of Steel piping AQUA FREE Water Inlet Water Outlet Safety piping RWMFSN1E 26~34 (1 ) 26~34 (1 ) 20~27 (3/4 ) Diameter of Copper piping AQUA FREE Water Inlet Water Outlet Safety piping RWMFSN1E 26~28 (1 ) 26~28 (1 ) 20~22 (3/4 ) Status of piping connection: Water outlet Size (1 ) 7 Safety piping Size (3/4 ) Water inlet Size (1 ) page 73
74
75 Electrical data 8. E l e c t r i c a l d a t a This chapter describes the electrical requirements for each unit of the AquaFREE modules and their complementary RASH(V)RNE outdoor units of Hitachi s DC Inverter series. Content 8. Electrical data AquaFREE module Outdoor Units page 75
76 Electrical data AquaFREE module Model Unit Main Power Applicable Voltage Water pump motor Electric resistance (V) F HZ Max Min. F RNC TP F RNC TP MC Aqua Free basic Aqua Free with electric heater RWM3FSN1E RWM4FSN1E RWM5FSN1E RWM3FSN1E4.5H RWM4FSN1E6H RWM5FSN1E6H RWM4FSN1E6H RWM5FSN1E6H Aqua Free basic for swimming pool Aqua Free for swimming pool and with electric heater RWM3FSN1ES1 RWM4FSN1ES1 RWM5FSN1ES1 RWM3FSN1ES14.5H1 RWM4FSN1ES16H1 RWM5FSN1ES16H1 RWM4FSN1ES16H3 RWM5FSN1ES16H3 To b e i n f o r m e d l a t e r (V): Supply Voltage (V) PH: Phase (φ) Hz: Frequency (Hz) RNC: Running Current (A) TP: Total power (kw) MC: Maximum Current(A) NOTE Specifications in these tables are subject to change without notice in order that HITACHI may bring the latest innovations to their customers page 76
77 Electrical data 8.2. Outdoor Units Model Unit Main Power Applicable Voltage U F HZ Max Min. F STC Total Power Consumption Cooling Operation Heating Operation RNC TP RNC TP MC RAS3HVRNE RAS4HVRNE RAS5HVRNE RAS4HRNE RAS5HRNE (V): Supply Voltage (V) PH: Phase (φ) Hz: Frequency (Hz) STC: Starting Current (A) RNC: Running Current (A) TP: Total Power (kw) MC: Maximum Current(A) NOTES 1. These values are in combination with AquaFREE module This data is based on the same conditions ase the nominal heating and cooling capacities. Refer to the notes of the Unit s General Data. Specifications in these tables are subject to change without notice in order that HITACHI may bring the latest innovations to their customers page 77
78
79 Electrical wiring and working mode setup 9. E l e c t r i c a l w i r i n g a n d s e t u p This chapter describes the electrical wiring connection and shows how to set the Dip switches in the new AquaFREE modules and the complementary RAS H(V)RNE outdoor units from Hitachi s DC Inverter series. Content 9. Electrical wiring and setup General check Setting and function of DIP Switches for Outdoor Units Setting and function of DIP Switches for AquaFREE module Main PCB Control PCB Common Wiring Electrical Wiring Between AquaFREE module and outdoor units page. 79
80 Electrical wiring and working mode setup 9.1 General check ATTENTION: Turn OFF the main power switch to the indoor unit and the outdoor unit before electrical wiring work or a periodical check is performed. Check to ensure that the outdoor fan have stopped before electrical wiring work or periodical check is performed. Protect the wires, drain pipe, electrical parts, etc. from rats or other small animals. If all these parts are not protected, rats or other small animals may gnaw at them. In the worst case, a fire may occur. Prevent the wires from touching the refrigerant pipes, plate edges and electrical parts inside the unit. Otherwise, the wires will be damaged and at the worst, a fire will occur. Do not touch the factory set Remote Controller of Electric Box. CAUTION: Tightly secure the wires with the cord clamp inside the indoor unit. NOTE: Fix the rubber bushes with adhesive when the ducts to the outdoor unit are not used. 1. Make sure that the fieldsupplied electrical components (main power switches, circuit breakers, wires, duct connectors and wire terminals) have been properly selected according to the electrical data given in this technical catalogue. Make sure that the components comply with the National Electrical code. 2. Check to ensure that the power supply voltage is within 10% of the rated voltage. 3. Check the capacity of the electrical wires. If the power source capacity is too low, the system cannot be started due to the voltage drop. 4. Check to ensure that the earth wire is connected. 5. Power Source Main Switch Install a multipole switch with a space of 3.5mm or more between each phase. page 80
81 Electrical wiring and working mode setup 9.2. Setting and function of DIP Switches for Outdoor Units NOTE: The mark indicates the position of the dip switches. The figures show the settings before the shipment or after the selection. When using DSW4, 5 the unit starts up or stops after 10 to 20 seconds after the switch is operated. CAUTION: Before setting DIP switches, first turn off power source. If the switches are set without turning off the power source, the contents of the setting are invalid. NOTE: Refer to service manual SM42 for additional information concerning switch settings of the RAS DC Inverter units. The PCB of the outdoor unit has 5 DIP switches (DSW) and 3 push switches (PSW) whose setting can be changed to perform unit maintenance and adapt the default configuration for each specific installation or operating mode. Layout of the Dip switches and pulse switches on the PCB: DIP Switch: DSW1: Startup test. Setting before shipment is all OFF (Refrigerant cycle No. 0). Setting before shipment Cycle num 0 ON DSW2: Setting Installation The following setting must be established for the outdoor unit to detect that it will be working with a AquaFREE module: DSW3: Unit Capacity. Setting before shipment Charge at installation ON ON Model Setting RAS3 HVRNE ON RAS4 HVRNE ON RAS5 HVRNE ON RAS4 HRNE ON RAS5 HRNE ON DSW4: Setting for the number of refrigerant cycles installed in the system. Setting Unit No. 0 ON DSW5: Transmission Setting of end Terminal Resistance. This setting is activated before shipment. To cancel this setting, change the position of Pin 1. Setting Before shipment ON Cancellation ON Push Switches: Manual defrosting For check PSW1 PSW2 PSW3 page. 81
82 Electrical wiring and working mode setup 9.3. Setting and function of DIP Switches for AquaFREE module AquaFREE module operate with two different PCBs: Main PCB Control PCB Main PCB NOTE: The mark indicates the position of the dip switches. The figures show the settings before the shipment or after the selection. The Main PCB of the AquaFREE module operates with four DIP switches, 1 slide switch and one rotating switch. RSW CAUTION: Before setting DIP switches, first turn off power source. If the switches are set without turning off the power source, the contents of the setting are invalid. DSW7 SSW DSW3 DSW5 DSW6 RSW: Indoor Unit nº setting. The rotating switch of the AquaFREE module must show position No. 1 The RWM units are delivered with this default setting. Setting position Position indicator DSW3: Unit Capacity. Model RWM3 RWM4 RWM5 Setting ON ON ON DSW5: Setting for the number of refrigerant cycles installed in the system. Setting Unit No. 0 ON DSW6: Indoor unit model setting Setting RWM ON page 82 DSW7: Fuse recovery / Remote Control setting Factory setting If high voltage is applied to terminal 1,2 of the Terminal board (TB), the fuse of the PCB will blow. In this case, first fix the wiring of the Terminal board (TB) and place pin No. 1 on ON, as shown in the figure. ON 1 2 ON 1 2
83 Electrical wiring and working mode setup Control PCB The control PCB has 4 rotational switches (RSW) and 2 groups of jumpers (JP) whose setting can be changed to perform unit maintenance and adapt the default configuration for each specific installation or operating mode. Layout of the switches and the jumpers in the PCB and in the electrical box: TH3 CN ON Cte CN2 CN3 E5 E4 E3 E2 E1 TH1 TH2 RC NOTE: The rotating switches (RSW) on the RWM units are located on the outside right part of the electrical box. RSW1: Room temperature (to activate the electric heater) (Factory setting 10ºC) RSW2: Water temperature (to activate and control the electric resistance) (Factory setting 34ºC) RSW3: Water temperature regulator (Water rule) (Factory setting 0.8) RWS4: Maximum water temperature regulator thermostat. (Factory setting 48ºC) Water Rule (RSW3) The Water rule is the straight line representing outdoor temperatures which results from the value in RSW3 (value of the slope), plus a constant. The possible water rules are represented graphically in the following way: 9 NOTE: The SW3 switch only exists on the units with electric resistances. NOTE: WB: Wet Bulb Water Temperature Ambient temperature (WB) page. 83
84 Electrical wiring and working mode setup Settings: of the control PCB NOTE: Factory settings of the switches and the Jumpers : NOTE: Use of the electric resistance: In order to optimize the Inverter function of the outdoor unit, it is recommended to not select the minimum temperature when in heating mode. This temperature must be selected when performing the startup of the unit in order to adapt it to the usage mode. Heating mode: The control PCB has a rotating switch (RSW3) which is used to adjust the temperature of the water in the heating circuit (radiant floor / radiator). For Radiant floor mode is recommended to select the rotary switch in the numbers 0.6/0.7/0.8/0.9/1 (Set temperature is increased, through the rotary switch position from (0.6 to 1)). For Radiator mode (or mix Radiators + Radiant floor) is recommended to select the rotary switch in the numbers 1.1/1.2/1.3/1.5/2 (Set temperature is increased, through the rotary switch position from (1.1 to 2)). Electric resistance: Activation: (Only in 4.5/6H1/3 units) When outdoor temperature conditions are extreme, the system can be helped by activating the electric resistance. To activate the electric resistance, you must set next conditions: Thermo ON condition, (compresor working) SW2 in Heat mode SW3 in ON The electric Heater starts up if one of the following premises occurs and unit is in Thermo ON, and Heat Mode 1: 1. If the outdoor temperature is lower than the temperature selected on RSW1 Up to 10 different positions can be selected, with a temperature range that runs from 10ºC to 20ºC. 2. If the water temperature is lower than the temperature selected on RSW2. Up to 10 different positions can be selected, with a temperature range that runs from 48ºC to 30ºC. Setting the electric resistance: Turning OFF: There are two ways to adjust the electric resistance, depending on how it is configured (JP2): Option A The system adjusts the electric resistance depending on the unit s Water rule (RSW3), and decides to turn the electric resistance off when the temperature of the water reaches the lower of the following values: Value defined in (RSW3) Water rule. Value defined in (RSW2) Water temperature for the electric resistance or Ambient temperature is higher than the value defined in RSW1. Option B The system adjusts the electric resistance until it reaches the value defined in RSW2 (water temperature for the electric resistance), or Ambient temperature is higher than the value defined in RSW1. Option A Option B NOTE: En (JP1) the goal is to keep the water temperature between 19ºC and 21ºC. The unit comes with a default setting of 19C. The JP of 7ºC is not available Cooling Mode: When in cooling mode, the desired water temperature must be selected by means of (JP1) Select the temperature depending on the relative humidity of the air. ON For dry areas, select low temperatures. (19ºC) For humid areas, select high temperatures (21ºC) Cte page 84
85 Electrical wiring and working mode setup 9.4 Common Wiring Electrical Wiring Between AquaFREE module and outdoor units ATTENTION: Furthermore, none of the safety protections must be activated. ATTENTION: Pay attention to the connection of the operating line. Incorrect connection may cause the failure of the PCB. CAUTION: All of the wiring and electrical components must comply the local standards of where they are to be installed. Connect the electrical wires between the indoor unit and the outdoor unit, as shown in the next diagram. Follow local codes and regulations when performing electrical wiring. If the refrigerant piping and the control wiring are connected to the units in the same refrigerant cycle. Use twist pair wire (more than 0.75 mm²) for operation wiring between outdoor unit and indoor unit, and operation wiring between indoor unit and indoor unit. Use 2core wire for the operating line (Do not use wire with more than 3 cores). Use shielded wires for intermediate wiring to protect the units from noise obstacle at length of less than 300m and size complied with local code. Open a hole near the connection hole of power source wiring when multiple outdoor units are connected from one power source line. The recommended breaker sizes are shown in Table of electrical data and recommended Wiring, Breaker Size/1 O.U. In the case that a conduit tube for fieldwiring is not used, fix rubber bushes with adhesive on the panel. All the field wiring and equipment must comply with local and international codes. ATTENTION: Pay attention to the connection of the operating line. Incorrect connection may cause the failure of PCB. Outdoor Unit Outdoor Unit 3 TB1 TB V Remote Control 3 Remote Control 9 NOTES: 230V 3 TB : CB : ELB : A B : 3 4 : Connections bar Circuit breakers Earthleakage breaker : Internal wiring : Fieldsupplied : Optional accessory Remote control switch Outdoor thermistor connection (non polarity) 5 6 : Room s thermostat connection Indoor Unit L1 L2 L3 Indoor Unit ATTENTION: Power suppply must be connected to outdoor unit and indoor unit separately. page. 85
86 Electrical wiring and working mode setup NOTE: Follow local codes and regulations when selecting field wires, Circuit breakers and Earth Leakage breakers. Use wires that are not lighter than the ordinary polychloroprene sheathed flexible cord (code designation H05RNF). The earth cable size must comply with standards: IEC 245, nº571. Recommended minimum sizes for field provided wiring: Model RWM3/4FSN1E Power Supply. Max Current Power source cable size EN A 0.75 mm² RWM5FSN1E 1 A 0.75 mm² RWM3FSN1E4.5H1 1Ø/230V/50Hz 20 A 2.5 mm² RWM4FSN1E6H1 32 A 6 mm² RWM5FSN1E6H1 32 A 6 mm² RWM4FSN1E6H3 11 A 2.5 mm² 3Ø/400V/50Hz RWM5FSN1E6H3 11 A 2.5 mm² RAS3HVRNE 25 A 4 mm² RAS4HVRNE 1Ø/230V/50Hz 32 A 6 mm² RAS5HVRNE 32 A 6 mm² RAS4HRNE 11 A 2.5 mm² 3Ø/400V/50Hz RAS5HRNE 15 A 2.5 mm² Transmitting cable size EN MLFC 0.75 mm² 0.5 mm² The wire sizes shown in the table above and marked with have been selected at the maximum current of the unit according to the European Standard, EN Selection according to EN Current i (A) I 6 Wire size 0.75 mm² 6 < i mm² 10 < i mm² 16 < i mm² 25 < i mm² 32 < i mm² 40 < i mm² Protection of the main switches Select the main switches according to the following table. Model Power Supply Maximum Current CB ELB Num. of poles/a/ma NOTE: ELB: Differential switch. CB: Magnetothermic switch.. RWM3/4FSN1E 1 A 6 A RWM5FSN1E 1 A 6 A 2 /40 / 30 RWM3FSN1E4.5H1 1Ø/230V/50Hz 20 A 25 A RWM4FSN1E6H1 32 A 40 A RWM5FSN1E6H1 32 A 40 A 2 / 63 / 30 RWM4FSN1E6H3 11 A 15 A 3Ø/400V/50Hz RWM5FSN1E6H3 11 A 15 A 4 / 40 / 30 RAS3HVRNE 25 A 32 A 2 / 40 / 30 RAS4HVRNE 1Ø/230/50Hz 32 A 40 A RAS5HVRNE 32 A 40 A 4 / 63 / 30 RAS4HRNE 11 A 15 A 3Ø/400V/50Hz RAS5HRNE 15 A 20 A 4 / 40 / 30 page 86
87 Remote control switch 10. R o o m T h e r m o s t a t O p e r a t i o n This chapter describes the operation of the room thermostat that the new AquaFREE modules use and their complementary RAS H(V)RNE outdoor units of Hitachi s DC Inverter series. Content 10. Room Thermostat Operation Remote control switch Display Operating mode selection: Control keypad Settings of the installed parameters of the PRT Language selection Connection between the receiver (AquaFREE) and the PRT Date and Time configuration Operation mode selection (Comfort, Reduction and No frost temperatures) Holidays mode selection Select and modify an established program Display of the programs profiles CAUTION Press switches only with fingers. Do not press switches by any other item, as it may damage the switches. Page 87 TCES0042 rev0 09/2006
88 Remote control switch Remote control switch Appearance: Operation mode Selection Switch Operation mode Selection Cursor auto Automatic Comfort Reduced Liquid Crystal Display (L.C.D) Area Upper Part: Lower Part: No Frost Stop / Holidays Current day indicator Hours and minutes indicator Transmission indicator Battery level indicator (+ / ) Switch Time function switch (date and time setting) Selection confirmation switch Holiday mode switch Holiday mode set symbol Room Temperature indicator Time switch (time adjustment) Switch to memorize program settings Comfort mode switch Cooling Heat Day switch 1 = Monday... 7 = Sunday Reset to initial setting switch. Program switch (operating mode) P1 = Program 1 (Heating / Cooling) P2 = Program 2 (Heating / Cooling) Features: The device (PRT) lets you program and select the temperature required for the room where it is installed. This device also lets you choose between 4 predefined programs (that can be changed) that adapt the temperature conditions of the room to your lifestyle. Its operation can even be adjusted during long holiday periods away from home. All the adjustments are displayed on its liquid crystal display. Thanks to its design, you can decide to install the device on the wall or on a table since both supports come as standard accessories. P3 = Program 3 (Heating / Cooling) P4 = Program 4 (Heating / Cooling) NOTE: In this chapter, the CTA IMH RF A remote control switch is defined as a PRT (Programmable Remote Transmitter) device. NOTE: The room s temperature will depend on the mode of use specified for this device This device includes a radio transmitter that allows it to be used as a wireless device. Page 88
89 Remote control switch Display Operation The liquid crystal display shows the user information about all the selected settings. Basic data is displayed in the upper part: Room temperature. Operation mode. Selected program. Day / Time. Battery status. Connection status (remote control switch / Water Free). ATTENTION Programming related data is displayed in the lower part: Specific programmed settings. Days of the week Operating mode selection: Operation The operating mode switch ( ) has 5 positions: Automatic mode. The unit runs according to the selected program. Comfort mode. The unit runs in heating mode in order to reach the selected temperature. Reduced mode. The unit runs in cooling mode in order to reach the selected temperature. No Frost Recommended when unit is stopped during the winter. The unit runs in protection mode to avoid that the temperature of the heating circuit drop below levels that could damage it. Stop mode (Stop/Holidays) Interruped operation mode. NOTE: The selected program can be changed at any time Control keypad Operation This palette of commands allows to modify the factory predefined programs and, for each program, to select the daily times of operation either in Heating or Cooling mode. In order to perform this operation, press the switches located below each symbol. ATTENTION ATTENTION 10 Page 89 TCES0042 rev0 09/2006
90 Remote control switch Settings of the installed parameters of the PRT Programming To modify the predefined settings of the parameters of your PRT, press 24h and OK simultaneously. You can modify the settings of the following parameters: Heating or Air conditioning ON/OFF or PID selection of setting a type Start/Stop of the optimization function Start/Stop of the pump protection system ATTENTION 24h NOTE: Validate the new setting with the OK switch ( ) Language selection Programming You can configure the language your remote control switch (PRT) will use to show the information on the Display. To change the language, press 0h and OK simultaneously. You can select from 10 different languages: French (FRA) Dutch (HOL) English (ENG) Finnish (SUO) ATTENTION 0h German (DEU) Norwegian (NOR) Italian (ITA) Swedish (SVE) Spanish (ESP) Danish (DEN) NOTE: Validate the new setting with the OK switch ( ) Connection between the receiver (AquaFREE) and the PRT Programming The following procedure has to be followed to establish communication between the Water Free unit and our PRT: 1. Put the receiver in memory mode. 2. Press the program selection switch (P1 to P4) of your PRT for 5 seconds. 3. The transmission indicator () of the PRT turns on to indicate that connection has been established. Perform the following operations and check that the unit responds adequately: Put your PRT in "comfort" mode. Increase the temperature setting of your PRT until your unit starts running. On your PRT put the operation mode cursor in the permanent "Stop" position. Your RWM unit should stop after a few seconds. ATTENTION NOTE: In order to the form of the procedure correctly, referred to the specific instructions for the receiver. Repeat the operation for each one of the receivers or auxiliary resistances that must operate with the PRT device Page 90
91 Remote control switch Date and Time configuration Programming To set the date and time on the PRT, put the unit in Automatic operation mode. Perform the following procedure: ATTENTION 1. Press () (Date and Time selector) Select the Hour with the selector () ( / ). Validate the selection by pressing (OK). Then select the minutes with the selector () ( / ). Validate the selection by pressing (OK). Finally, select the day of the week with the selector () ( / ). Validate the selection by pressing (OK) Operation mode selection (Comfort, Reduction and No frost temperatures) Programming You can change the predefined values of the different operation modes. Perform the following procedure to change these values: ATTENTION 1. Move the operation mode selection cursor () to the required mode. 2. Change the value with the () ( / ) selector and put the operation mode selection cursor back in () the Auto mode Holidays mode selection Programming The Holidays mode allows to interrupt the heating or cooling program during a period of absence (from 1 to 99 days). This is only possible when in the Automatic operation mode. To activate the Holidays mode, follow the instructions below: 1. First, but the unit in Automatic mode with the selection cursor (). 2. Press () 3. Set the number of days you wish to interrupt the heating or cooling program (from 01 to 99). 4. Validate your selection by pressing (OK) Example: Today = Monday Programmed = 3 days Return to Auto mode = Tuesday at 0h01m If you want to interrupt the Holidays mode, just move the () cursor from Auto to Reduced and back again to Auto. With this action, your PRT device will once again run with the selected program, and the Holidays mode will be deactivated ATTENTION 10 NOTE: In Holidays mode of the, when programming the number of days, the current day counts as one. Page 91 TCES0042 rev0 09/2006
92 Remote control switch Select and modify an established program Programming Your thermostat comes with 4 factory preset programs for the heating or cooling functions. The values defined for each program can be easily modified with the switches located beneath the cover of your PRT. These programs correspond to the different user profiles (home, office, personnel, elderly, etc...). The factory defined values for the programs are: Heating Mode P1: Every day of the week, comfort from 06h00 to 23h00 P2: From Monday to Friday, comfort from 06h00 to 09h00 and from 16h00 to 23h00 From Saturday to Sunday, comfort from 06h00 to 23h00 P3: From Monday to Friday, comfort from 06h00 to 09h00, from 11h00 to 14h00 and from 16h00 to 23h00 From Saturday to Sunday, comfort from 06h00 to 23h00 P4: Every day of the week, comfort from 00h00 to 24h00 Cooling Mode P1: Every day of the week, reduced from 06h00 to 23h00 P2: From Monday to Friday, cooling from 06h00 to 09h00 and from 16h00 to 23h00 From Saturday to Sunday, cooling from 06h00 to 23h00 P3: From Monday to Friday, cooling from 06h00 to 09h00, from 11h00 to 14h00 and from 16h00 to 23h00 From Saturday to Sunday, cooling from 06h00 to 23h00 P4: Every day of the week, cooling from 00h00 to 24h00 ATTENTION To change one of these predefined profiles, follow the procedure below: 1. Select the number of the program you want to modify 2. Select the day of the week with the () switches, and indicate the time by pressing (). (/+). Afterwards, choose Comfort or Reduced for the Heating or Cooling function. You can also copy the profile from one day to another. To perform this operation, follow the procedure below: 1. Keep the switch of the day you want to copy from pressed, and at the same time press the switch of the day you want to copy to. In the same way you can also copy one complete profile (7 days) to another profile NOTE: To modify the preset values the selection cursor must be in Auto mode Display of the programs profiles Programming To display the profiles that have been memorized, follow the procedure below: ATTENTION 1. Place the operation mode selection cursor () on "Auto" mode. 2. Press the switch of the profile you want to display, and display the configuration by selecting the day. Page 92
93 Available optional functions 11. A v a i l a b l e o p t i o n a l f u n c t i o n s This chapter gives a brief explanation of the available optional functions for the new Hitachi AquaFREE system Content 11. Available optional functions Available optional functions for outdoor units page 93
94 Available optional functions Available optional functions for outdoor units The following table gives information concerning the optional functions that are available for the AquaFREE series Optional functions Outdoor Unit Series Optional Function Explanation H(V)RNE Night mode operation (low sound level) This function decreases the sound level of the units, as well as the cooling capacity. Defrosting condition change over This function changes the defrosting operation conditions. It is specially interesting for cold areas. Available page 94
95 Troubleshooting 12. T r o u b l e s h o o t i n g This chapter provides you with a concise description of the most common alarm codes of the new Hitachi AquaFREE system. Content Alarm Code Indication of Remote Control Switch: Alarm codes page 95 TCGB0042 rev.009/2006
96 Troubleshooting Alarm Code Indication of Remote Control Switch: Alarm Code Model code Alarm Code Model code Indication Model Heat pump ADDS RN RN Indicated for a second alternately Inverter Multi Cooling only Others Alarm codes Code No. Item Content of Abnormality Main cause 01 Indoor Unit Tripping of the protection device Activation of the flow rate controller, low water level pressure switch. 02 Outdoor unit Tripping of the protection device Activation of PSH, Locked Motor Transmission Abnormality between Indoor (or Outdoor) and Outdoor (or Indoor) units Abnormality between Inverter and Control PCB Incorrect Wiring., failure of PCB (indoor or outdoor), fuse disconnected, fuse blown, power supply (module or outdoor unit) OFF Failure in Transmission between PCBs (for the Inverter) 05 Abnormality of power source wiring Reverse phase incorrect wiring 06 Voltage Drop Voltage Drop by Excessively Low or High Voltage in Outdoor Unit 07 Decrease in the discharge gas superheat Cycle 08 Increase in the discharge gas temperature Power Supply Voltage Dropy, Incorrect Wiring or insufficient Capacity of Power Supply Wiring Excessive Refrigerant Charge, Expansion Valve Open Lock Insufficient Refrigerant charge, refrigerant leakage, expansion valve lock closed or clogged 11 Control PCB 12 Heater assigned in THM2 13 Sensor on the indoor unit Freeze Protection Thermistor Failure of Thermistor, control card, Connection 14 Gas Pipe Thermistor 19 Flow controller blocked Cranck the controller. Check pump operation page 96 TCGB0042 rev.009/2006
97 Troubleshooting Alarm codes (Cont.) Code No. Item Content of Abnormality Main cause 20 Compressor thermistor 22 Outdoor Air Thermistor Failure of thermistor, sensor, or connection 24 Evaporation thermistor Sensor on the Outdoor Unit 31 Incorrect setting of Outdoor and Indoor Units Incorrect setting of capacity code 35 Incorrect setting of Indoor Unit No. Duplication of the Indoor Unit number 38 Abnormality of Protective Circuit in Outdoor Unit Faulty PCB in the the outdoor unit, incorrect connection of cabling to PCB in indoor unit Pressure Surcharge in cooling mode (highpressure pressures switch tripped) Overcharge in cooling mode (highpressure pressures switch tripped) Activation of Low Pressure Decrease Protection Device Check air flow rate of a condenser (fan motor, battery). Presence of noncondensed gas Refrigerant overcharge Presence of noncondensed gas Refrigerant overcharge Check the pump (insufficient water flow rate). Stoppage due to excessive decrease of evaporation temperature (Te < 35 ºC) activated three times in one hour, incorrect overheating (lack of gas), insufficient water flow rate 51 Abnormality of Current Sensor for Inverter Failure of Control PCB, ISPM 52 Activation of Overcurrent protection Inverter 53 Activation of ISPM protection 54 Increase in Inverter Fin Temperature Failure of ISPM, Clogging of Heat Exchanger, Locked Compressor ISPM failure, compressor failure, clogging of heat exchanger Abnormal Inverter fin thermistor Clogging of the heat exchanger Outdoor unit fan abnormality 55 ISPM ISPM Abnormality Faulty ISPM 57 Outdoor Fan Fan Motor Abnormality Disconnected wire or in correct wiring between the control PCB and the Inverter PCB Incorrect wiring or abnormality of the fan motor EE Compressor Compressor Protection Alarm Failure of Compressor. 12 page 97 TCGB0042 rev.009/2006
98
99
100 HITACHI is participating in the EUROVENT Certification Programme. Products are as specified in the EUROVENT Directory of Certified Products. HitachiAir Conditioning Products Europe, S.A. Ronda Shimizu,1 Políg. Ind. Can Torrella Vacarisses (Barcelona) España ISO 9001 Certified byaenor, Spain ISO Certified byaenor, Spain Hitachi Air Conditioning Systems Operation Shimizushi, Shizuokaken, Japan ISO 9001 Certified by JQA, Japan ISO Certified by JQA, Japan Hitachi Air Conditioning Products (M) Sdn. Bnd. Lot No. 10, Jalan Kemajan Bangi Industrial Estate Bandar Baru Bangi, Selangor Darul Ehsan, Malaysia Certification ISO 9001, Malaysia Certification ISO 14001, Malaysia Printed in Spain
AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
YUTAKI SERIES. Technical Catalogue. Air-to-water Heating Chiller: RHUE3AVHN RHUE4AVHN RHUE5AVHN RHUE5AHN
YUTAKI SERIES Technical Catalogue Air-to-water Heating Chiller: RHUE3AVHN RHUE4AVHN RHUE5AVHN RHUE5AHN Specifications in this manual are subject to change without notice in order that HITACHI may bring
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal
Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Appendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
Versati Air to Water Heat Pump
Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW
utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
YUTAKI S. Domestic Heating
YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance
YUTAKI S SERIES. Technical Catalogue. RWM-FSN3E Indoor units RAS-H(V)RNME-AF Outdoor units RAS-HVRN2 Outdoor unit
YUTAKI S SERIES Technical Catalogue RWM-FSN3E Indoor units RAS-H(V)RNME-AF Outdoor units RAS-HVRN2 Outdoor unit Contents C o n t e n t s General information Features and benefits General data Capacities
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
NEW 3-PIPE ECOi MF2 SERIES
NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR
SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2
SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED
Condensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
How To Make A High Efficiency Thermostat
Zoning with Variable Speed Mini-Split Systems Fujitsu Service Training Welcome - Thank you for attending Did you know? In 1940 only 42% of homes in the US had central heating In 1970 20% of homes had central
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV
Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
Air Conditioners Technical Data
Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS 2011 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
Refrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter
Chiller/Heat pumps 30AWH Reversible Monobloc inverter C O M P A C T, R E L I A B L E A N D E F F I C I E N T Reversible Compact, reliable and efficient 2 The new AquaSnap PLUS chillers and reversible heat
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS 2011 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total sales
Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and
1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
TWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
KONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
New Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3
DM13-01.01.01en Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 Contents Part 1 General Information... 1 Part 2 Selection
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Split units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
Development and testing of a multi-type air conditioner without using AC inverters
Energy Conversion and Management 46 (2005) 373 383 www.elsevier.com/locate/enconman Development and testing of a multi-type air conditioner without using AC inverters Shih-Cheng Hu *, Rong-Hwa Yang Department
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using