NEW 3-PIPE ECOi MF2 SERIES
|
|
|
- Bryce Craig
- 9 years ago
- Views:
Transcription
1 NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR TEMPERATURE 5 year compressor warranty The New Panasonic 3-Pipe 6N Series offers the best to the most demanding customers. The new 3 way have only 1 size of chassis with very limited foot print (only 0.93 m²) 1 body for all sizes: H1.758 x W1.000 x D mm, for 8, 10, 12, 14 and 16 HP Maximum capacity size as 48HP by 3 units combinations (16 HP x 3 = 48 HP) Up to 52 indoor units connectable Maximun capacity ratio of 150% 70
2 NEW VRF SYSTEMS ECOi COP 4,77 Large combination of outdoor units, up to 48 HP High efficiency combination System (HP) System (HP) Inverter unit Inverter unit Top of de market COP (at full load), standard efficiency COP EER HP 10 HP 12 HP 14 HP 16 HP NEW 3-PIPE 6 SERIES OLD SERIES HP 10 HP 12 HP 14 HP 16 HP NEW 3-PIPE 6 SERIES OLD SERIES EFFICIENCY FIC IENC Heating Cooling 71
3 Connectable indoor/outdoor unit capacity ratio up to 150% Extended operating range Cooling operation range: The cooling operation range has been extended to -10 ºC by changing the outdoor fan to an inverter type. New Solenoid valve kit Non-stop Oil-recovery operation to gives more stable comfort airconditioning control. New design to decrease chattering (bank the body 90 degrees) All now packaged in the same box. 3-PIPE CONTROL SOLENOID VALVE KIT 3-PIPE CONTROL PCB Outside air temperature (ºC DB) Heating operation range: Stable heating operation even with an outside air temperature of -20 ºC. The heating operation range has been extended to -20 ºC by use of a compressor with a high-pressure vessel. CZ-P56HR3 Up to 5.6 kw CZ-P160HR3 From 5.7 to 16 kw KIT-P56HR3 (CZ-P56HR3+CZ-CAPE2) KIT-P160HR3 (CZ-P160HR3+CZ-CAPEK2) 3-Pipe control PCB CZ-CAPE2*. Must be added to the CZ-P56HR3 OR CZ-P160HR3. * For wall mounted S-22MK2E5/S-28MK2E5/S-36MK2E5. For S-45MK1E5/S-56MK1E5/S-73MK1E5/S-106MK1E5: CZ-CAPEK Outside air temperature (ºC WB) Wide temperature setting range Wired remote control heating temperature setting range is 16 to 30 ºC. Individual control of multiple indoor units with solenoid valve kits Any design and layout can be used in a single system. Cooling operation is possible up to an outdoor temperature of -10 ºC. Increased piping lengths and design flexibility Adaptable to various building types and sizes. Actual piping length: 180 m. Maximum piping length: 500 m. Up to max. 40 indoor units COOLING HEATING HEATING STOP COOLING STOP MAX. TOTAL LENGTH: 500 M System difference of elevation: 50 m * Difference in elevation between indoor units: 15 m Difference between the Max - Min tubing lenght after the first branch 40 m Maximum Length (indoor/outdoor) 180 m * 40 m if the outdoor unit is below the indoor unit. Liquid pipe Discharge pipe (medium-temperature, (high-temperature, medium-pressure liquid pipe) high-pressure gas pipe) Compactness for superb space and low noise level 5 types of outdoor units with different capacities have been standardized to one compact casing size. Uniquely constructed with two-part compartments, the upper room contains heat exchanger while the lower two-part stores compressors. The benefits are two-fold - superb space and low noise level. INSTALLATION SPACE: 0.79 m² (In case of 16 HP) Suction pipe (low-temperature, low-pressure gas pipe) Individual control Non-stop operation during maintenance Even when an indoor unit needs maintenance, the other indoor units can be kept operating by setting. (Not applicable for all situations) 1000 Power suppression control for energy (Demand control)¹ The 3-Pipe ECOi MF2 series has a built-in demand function which uses the inverter characteristics. With this demand function, the power consumption can be set in three steps, and operation² at optimum performance is performed according to the setting and the power consumption. This function is useful to reduce the annual power consumption and to save electricity fees while maintaining comfort OPERATING SOUND db(a) 1 An outdoor Seri-Para I/O unit is required for demand input. 2 Setting is possible as 0% or in the range from 40 to 100% (in steps of 5%). At the time of shipping, setting has been done to the three steps of 0%, 70%, and 100% Standard Silent mode HP 10 HP 72
4 NEW VRF SYSTEMS ECOi Excellent cost and realization of smaller piping size By adoption of R410A with low pressure loss, it became possible to reduce the pipe sizes for discharge, suction and liquid pipes. This makes it possible to aim for reduced piping space, improved workability at the site, and reduction of the piping material costs. Extended compressor life The total operation time of the compressors is monitored by a microcomputer, so that there is no imbalance for the operation times of all compressors in the same refrigerant system, and compressors with a shorter operation time are operated with preference. Piping Insulation ø HP 10 HP ø22.22 A, C: DC inverter compressor B, D: Constant speed compressor Load increase Load increase Load increase ø15.88 ø9.52 ø19.05 ø9.52 A B C D A B C D A B C D A B C D (mm) 50 h 30 h 60 h 10 h 3-PIPE ECOi MF2 HP SUCTION PIPE DISCHARGE PIPE LIQUID PIPE 8 Ø Ø Ø Ø Ø Ø 9.52 Piping design Balance tubing Main piping length LM = LA + LB Main distribution pipes LC-LH are selected according to the capacity after the distribution joint. Size of indoor unit connection piping 1-40 is determined by the connection piping size on the indoor units. For extension T-joint tubing (header joint system) L3 7 The outdoor connection main tubing (LO portion) is determined by the total capacity of the outdoor units that are connected to the tube ends. Max. 400 mm For extension EXPLANATION OF SYMBOLS Distribution joint (CZ, option) Ball valve (BV, option) T-joint (field supply) Solidly welded shut (pinch weld) Note: Do not use commercial T-pieces for the liquid pipes of and. Max. 400 mm Solenoid Valve Kit 1 R410A distribution joint * Be sure to use R410A distribution joints for outdoor unit connections and piping branches. 1. The connection between the indoor unit(s) and the solenoid valve kit(s) has three (3) types of methods. For further details, refer to the Section Connecting Multiple Indoor Units to a Single Solenoid Valve Kit. RANGES THAT APPLY TO REFRIGERANT PIPING LENGTHS AND TO DIFFERENCES IN INSTALLATION HEIGHTS Items Marks Contents Length (m) Allowable piping length L1 Max. piping length Actual piping length 180 Equivalent piping length 200 Δ L (L2 L4) Difference between the max. length and the min. length from the No. 1 distribution 40 LM Max. length of main piping (at max. diameter) 3 1, 2~ 40 Max. length of each distribution 30 L A+ B+LF+LG+LH Total max. piping length including length of each distribution (only liquid tubing) L5 Distance between outdoor units 10 Allowable elevation difference H1 When outdoor unit is installed higher than indoor unit 50 When outdoor unit is installed lower than indoor unit 40 H2 Max. difference between indoor units 15 H3 Max. difference between outdoor units 4 Allowable length of joint tubing L3 T-joint tubing (field-supply); Max. tubing length between the first T-joint and solidly welded-shut end point 2 L = Length, H = Height 1. The outdoor connection main tubing (LO portion) is determined by the total capacity of the outdoor units that are connected to the tube ends. 2. If the longest tubing length (L1) exceeds 90 m (equivalent length), increase the sizes of the main tubes (LM) by 1 rank for the discharge tubes, suction tubes, and narrow tubes. (field supplied). 3. If the longest main tube length (LM) exceeds 50 m, increase the main tube size at the portion before 50 m by 1 rank for the suction tubes and discharge tubes. (field supplied). (For the portion that exceeds 50 m, set based on the main tube sizes (LA) listed in the table on the following page) HP - 3 0HP of high efficiency combination is 300 m. 73
5 Energy Energy 8-16 HP // 3-PIPE ECOi MF2 SERIES WITH SIMULTANEOUS HEATING AND COOLING OPERATION HEAT RECOVERY TYPE ECOi 3-Pipe is one of the most advanced VRF systems available. Not only offering high-efficiency and performance for simultaneous heating and cooling, Its sophisticated design makes installation and maintenance much easier. Conforms to COP 4.77 as the top class in the industry (Average cooling and heating value for 8 HP outdoor unit). Simultaneous cooling or heating operation for up to 52 indoor units. Small installation space, top class in the industry. Rotation operation function and back-up operation function provided. TECHNICAL FOCUS Internet Control Ready INTERNET CONTROL Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR TEMPERATURE 5 year compressor warranty STANDARDIZATION OF O_U TO ONE COMPACT CASING SIZE IMPROVED OPERATION EFFICIENCY THE CONSTANT-SPEED COMPRESSOR ADOPTS A HIGH- PERFORMANCE INTERNAL HIGH-PRESSURE SCROLL IMPROVEMENT OF THE HEAT EXCHANGER RELAYOUT OF STRUCTURAL PARTS CLOSE SIDE-BY-SIDE INSTALLATION IS POSSIBLE HP MODEL NAME U-10MF2E8 U-12MF2E8 Power supply 380 / 400 / 415 V - Three Phase / 50 Hz Cooling capacity kw BTU/h 76,500 95, , , ,600 EER W/W Running current 380 / 400 / 415 V A 8.60 / 8.17 / / 10.8 / / 14.5 / / 18.9 / / 21.6 / 21.0 Power input kw Heating capacity kw BTU/h 85, , , , ,600 COP W/W Running current 380 / 400 / 415 V A 8.95 / 8.50 / / 11.0 / / 14.1 / / 16.4 / / 19.9 / 19.4 Power input kw Dimensions H x W x D mm 1758 x 1000 x 1758 x 1000 x 1758 x 1000 x 1758 x 1000 x 1758 x 1000 x Net weight Kg Air circulation m³/min Refrigerant amount at shipment Kg Piping connections Suction pipe mm (Inch) Ø (7/8) Ø (1) Ø (1-1/8) Ø (1) Ø (1-1/8) Discharge pipe mm (Inch) Ø (5/8) Ø (3/4) Ø (3/4) Ø (7/8) Ø (7/8) Liquid pipe mm (Inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø (1/2) Ø (1/2) Ø (1/2) Balance pipe mm (Inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ambient temperature operating range Cooling/Dry: -10 ºC~+46 ºC (DB). Heating: -20 ºC~+18 ºC (WB) Simultaneous operation: -10 ºC~+24 ºC (DB) Sound pressure level High / Low dba 57.0 / / / / / 59.0 Sound power level Normal mode db 71.5 / / / / / 73.5 GLOBAL REMARKS Rated conditions: Cooling Heating Indoor air temperature 27 ºC DB / 19 ºC WB 20 ºC DB Outdoor air temperature 35 ºC DB / 24 ºC WB 7 ºC DB / 6 ºC WB Specifications subject to change without notice. 74
6 NEW VRF SYSTEMS ECOi COP 4,77 NEW System limitations Max. number of combined outdoor units 3 Max. HP of combined outdoor units 135 kw (48 HP) Max. number of connectable indoor units 52 Indoor/outdoor unit capacity ratio % Additional refrigerant charge LIQUID PIPING AMOUNT OF REFRIGERANT SIZE CHARGE/m (g/m) LIQUID PIPING AMOUNT OF REFRIGERANT SIZE CHARGE/m (g/m) Ø Ø Ø Ø Ø Ø Ø Refrigerant piping PIPING SIZE (mm) O MATERIAL 1/2 H, H MATERIAL Outer diameter Wall thickness Outer diameter Wall thickness Ø Ø Ø Ø Ø Ø Ø Ø 38.1 over 1.35 Ø Ø over 1.45 Ø Note: When pipe bending is to be performed, the bending radius shall be at least 4 times the outer diameter. Also, take sufficient care to prevent pipe collapse and damage at the time of bending. TOP VIEW FRONT VIEW Electrical component box SIDE VIEW C A B 970 (Installation hole pitch) (104) Air discharge According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A: 894 (Installation hole pitch) * The tubing is routed out from the front. B: 730 (Installation hole pitch) * The tubing is routed out from the bottom. C: 730 (Installation hole pitch) * Installation fixing bracket, installation side * * 75
7 Energy Energy 3-PIPE ECOi MF2 SERIES // COMBINATION FROM 18 TO 48 HP WITH SIMULTANEOUS HEATING AND COOLING OPERATION HEAT RECOVERY TYPE ECOi 3-Pipe is one of the most advanced VRF systems available. Not only offering high-efficiency and performance for simultaneous heating and cooling, Its sophisticated design makes installation and maintenance much easier. Conforms to COP 4,63 as the top class in the industry (Average cooling and heating value for 8 HP outdoor unit). Simultaneous cooling or heating operation for up to 52 indoor units. Small installation space, top class in the industry. Rotation operation function and back-up operation function provided. TECHNICAL FOCUS Internet Control Ready INTERNET CONTROL Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR TEMPERATURE 5 year compressor warranty STANDARDIZATION OF O_U TO ONE COMPACT CASING SIZE IMPROVED OPERATION EFFICIENCY THE CONSTANT-SPEED COMPRESSOR ADOPTS A HIGH- PERFORMANCE INTERNAL HIGH-PRESSURE SCROLL IMPROVEMENT OF THE HEAT EXCHANGER RELAYOUT OF STRUCTURAL PARTS CLOSE SIDE-BY-SIDE INSTALLATION IS POSSIBLE HP MODEL NAME U-10MF2E8 U-12MF2E8 U-12MF2E8 Power supply 380 / 400 / 415 V - Three Phase / 50 Hz Cooling capacity kw BTU/h 172, , , , , , ,100 EER W/W ,72 3,54 3,39 3,41 Running current 380 / 400 / 415 V A 19.7 / 18.9 / / 22.9 / / 26.5 / / 30.2 / / 32.8 / / 36.6 / / 40.4 / 39.4 Power input kw ,29 20,64 23,18 24,90 Heating capacity kw BTU/h 192, , , , , , ,200 COP W/W Running current 380 / 400 / 415 V A 20.4 / 19.6 / / 22.9 / / 24.2 / / 29.2 / / 29.8 / / 31.3 / / 36.2 / 35.3 Power input kw Dimensions H x W x D mm 1758 x 2060 x 1758 x 2060 x 1758 x 2060 x 1758 x 2060 x 1758 x 2060 x 1758 x 2060 x 1758 x 2060 x Net weight Kg Air circulation m³/min Refrigerant amount at shipment Kg Piping connections Suction pipe mm (Inch) Ø (1-1/8) Ø Ø Ø Ø (1-1/4) Ø Ø Discharge pipe mm (Inch) Ø (7/8) Ø Ø (1) Ø Ø Ø Ø Liquid pipe mm (Inch) Ø (5/8) Ø Ø Ø Ø (3/4) Ø Ø Balance pipe mm (Inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ambient temperature operating range Cooling/Dry: -10 ºC~+46 ºC (DB). Heating: -20 ºC~+18 ºC (WB) Simultaneous operation: -10 ºC~+24 ºC (DB) Sound pressure level High / Low dba 62.0 / / / / / / / 62.5 Sound power level Normal mode db 76.5 / / / / / / / 77.0 GLOBAL REMARKS Rated conditions: Cooling Heating Indoor air temperature 27 ºC DB / 19 ºC WB 20 ºC DB Outdoor air temperature 35 ºC DB / 24 ºC WB 7 ºC DB / 6 ºC WB Specifications subject to change without notice. 76
8 NEW VRF SYSTEMS ECOi 150% CAPACITY RATIO NEW U-12MF2E8 380 / 400 / 415 V - Three Phase / 50 Hz , , , , , , , , ,800 3,38 3,75 3,59 3,58 3,58 3,39 3,40 3,40 3, / 43.1 / / 41.7 / / 45.2 / / 48.6 / / 52.0 / / 55.2 / / 58.6 / / 62.7 / / 64.7 / ,62 25,62 28,16 29,88 31,60 34,77 36,49 38,21 39, , , , , , , , , , / 40.1 / / 39.4 / / 39.9 / / 44.3 / / 49.6 / / 47.3 / / 51.6 / / 56.5 / / 60.1 / x 2060 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x Ø Ø Ø (1-1/2) Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Ø 6.35 (1/4) Cooling/Dry: -10 ºC~+46 ºC (DB). Heating: -20 ºC~+18 ºC (WB) Simultaneous operation: -10 ºC~+24 ºC (DB) 65.5 / / / / / / / / / / / / / / / / / / 78.5 SYSTEM EXAMPLE Outdoor unit If your indoor capacity load changes in the future, it s easy to add on both indoor and outdoor units using the same pipings. If the additional instalment of outdoor and indoor units is expected, the size of refrigerant piping should be decided according to the total capacity after the addition. CONNECTION Panasonic make it possible to link outdoor units together for a large capacity (48 HP) CONCENTRATION Since all pipings are concentrated into one pipe shaft, you can minimise piping space and construction labour. Solenoid valve kit If indoor/outdoor units need servicing, a ball valve (optional) cuts off non-operational units to let other units stay running. ADDITION Indoor unit 77
9 Energy Energy 3-PIPE ECOi MF2 SERIES // HIGH EFFICIENCY COMBINATION 16 TO 32 HP WITH SIMULTANEOUS HEATING AND COOLING OPERATION HEAT RECOVERY TYPE ECOi 3-Pipe is one of the most advanced VRF systems available. Not only offering high-efficiency and performance for simultaneous heating and cooling, Its sophisticated design makes installation and maintenance much easier. Conforms to COP 4.76 as the top class in the industry (Average cooling and heating value for 8 HP outdoor unit). Simultaneous cooling or heating operation for up to 52 indoor units. Small installation space, top class in the industry. Rotation operation function and back-up operation function provided. TECHNICAL FOCUS Internet Control Ready INTERNET CONTROL Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR TEMPERATURE 5 year compressor warranty STANDARDIZATION OF O_U TO ONE COMPACT CASING SIZE IMPROVED OPERATION EFFICIENCY THE CONSTANT-SPEED COMPRESSOR ADOPTS A HIGH- PERFORMANCE INTERNAL HIGH-PRESSURE SCROLL IMPROVEMENT OF THE HEAT EXCHANGER RELAYOUT OF STRUCTURAL PARTS CLOSE SIDE-BY-SIDE INSTALLATION IS POSSIBLE HP MODEL NAME U-10MF2E8 U-12MF2E8 U-12MF2E8 U-12MF2E8 Power supply 380 / 400 / 415 V - Three Phase / 50 Hz Cooling capacity kw BTU/h 153, , , , , ,200 EER W/W ,94 3,90 Running current 380 / 400 / 415 V A 17.3 / 16.4 / / 24.9 / / 27.4 / / 31.0 / / 35.5 / / 37.4 / 36.4 Power input kw ,55 23,08 Heating capacity kw BTU/h 170, , , , , ,300 COP W/W Running current 380 / 400 / 415 V A 17.9 / 17.0 / / 26.3 / / 27.9 / / 31.1 / / 33.6 / / 36.8 / 35.9 Power input kw 10,48 16,04 17,76 19,15 23,40 22,68 Dimensions (Combination) H x W x D mm 1758 x 2060 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x 1758 x 3120 x Net weight Kg Air circulation m³/min Refrigerant amount at shipment Kg Piping connections Suction pipe mm Ø Ø Ø Ø Ø Ø Discharge pipe mm Ø Ø Ø Ø Ø Ø Liquid pipe mm Ø Ø Ø Ø Ø Ø Balance pipe mm Ø 6.35 Ø 6.35 Ø 6.35 Ø 6.35 Ø 6.35 Ø 6.35 Ambient temperature operating range Cooling/Dry: -10 ºC~+46 ºC (DBT). Heating: -20 ºC~+18 ºC (WBT) Simultaneous operation: -10 ºC~+24 ºC (DBT) Sound pressure level High / Low db(a) 60.5 / / / / / / 62.0 Sound power level Normal mode db 75.0 / / / / / / 76.5 GLOBAL REMARKS Rated conditions: Cooling Heating Indoor air temperature 27 ºC DB / 19 ºC WB 20 ºC DB Outdoor air temperature 35 ºC DB / 24 ºC WB 7 ºC DB / 6 ºC WB Specifications subject to change without notice. 78
10 NEW VRF SYSTEMS ECOi COP 4,77 NEW Top of de market COP (at full load), standard efficiency NEW 3-PIPE 6 SERIES COP NEW 3-PIPE 6 SERIES EER HP 24HP 26HP 28 HP 30 HP 32 HP HP 24HP 26HP 28 HP 30 HP 32 HP HIGH COP COMBINATION STANDARD COMBINATION HIGH COP COMBINATION STANDARD COMBINATION TOP VIEW FRONT VIEW Electrical component box SIDE VIEW C A B 970 (Installation hole pitch) (104) Air discharge According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A: 894 (Installation hole pitch) * The tubing is routed out from the front. B: 730 (Installation hole pitch) * The tubing is routed out from the bottom. C: 730 (Installation hole pitch) * Installation fixing bracket, installation side * * 79
11 Design of 3WAY SYSTEM 4. Installation Instructions AVOID: DO: Outdoor Unit 4-1. Selecting the Installation Site for Outdoor Unit heat sources, exhaust fans, etc. damp, humid or uneven locations indoors (no-ventilation location) choose a place as cool as possible. choose a place that is well ventilated. allow enough room around the unit for air intake/ exhaust and possible maintenance. Hot air Outdoor unit Exhaust fan Heat source ** More than 50 mm Example of installation of 2 units (when 3 sides are open and only 1 side is shuttered) *** More than 60 mm * More than 300 mm ** More than 50 mm More than 500 mm * Make a walk-in space behind the unit to erase maintenance and servicing. ** When setting the anchor bolt to position B or C (See Fig. 4-3), make the space between the unit and the wall more than 250 mm for installation operation. *** When setting the anchor bolt to position B or C (See Fig. 4-3), make the space between the outdoor units more than 180 mm for installation operation. Fig Installation Space Install the outdoor unit where there is enough space for ventilation. Otherwise the unit may not operate properly. Fig. 4-2 shows the minimum space requirement around the outdoor units when 3 sides are open and only 1 side is shuttered, with open space above the unit. The mounting base should be concrete or a similar material that allows for adequate drainage. Make provisions for anchor bolts, platform height, and other site-specific installation requirements. NOTE CAUTION Fig. 4-1 Leave space open above the unit. Construct louvers or other openings in the wall, if necessary, to ensure adequate ventilation. Do not do any wiring or tubing within 30 cm of the front panel, because this space is needed as a servicing space for the compressor. Ensure a base height of 100 mm or more to ensure that drainage water does not accumulate and freeze around the bottom of the unit. If installing a drain pan, install the drain pan prior to installing the outdoor unit. * Make sure there is at least 150 mm between the outdoor unit and the ground. Also, the direction of the tubing and electrical wiring should be from the front of the outdoor unit Top view Air intake Side view Installation anchor hole ( elongated holes) 970 (Installation hole pitch) 1000 Air intake * According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A : 894 (Installation hole pitch) * For removing tube forward B : 730 (Installation hole pitch) * For removing the tube downward C : 730 (Installation hole pitch) C B Fig. 4-3 A 1758 Unit: mm
12 1. Outdoor Unit 1-5. Noise Criterion Curves, U-10MF2E8, U-12MF2E8,, Standard mode Quiet mode Sound pressure level (db) (0dB = μbar) Sound pressure level (db) (0dB = μbar) MODEL : SOUND LEVEL : 57.0 db (A) (Quiet mode 54.0) 40 NC-40 Approximate 30 minimum audible limit for NC continuous noise Overall Frequency at center of sound pressure band (Hz) CONDITION : 1 m in front at height of 1.5 m MODEL : U-12MF2E8 SOUND LEVEL : 61.0 db (A) (Quiet mode 58.0) CONDITION : 1 m in front at height of 1.5 m NC-60 NC-50 NC-60 NC NC-40 Approximate 30 minimum audible limit for NC-30 continuous noise 20 Overall Frequency at center of sound pressure band (Hz) Sound pressure level (db) (0dB = μbar) Sound pressure level (db) (0dB = μbar) MODEL : U-10MF2E8 SOUND LEVEL 59.0 db (A) : (Quiet mode 56.0) CONDITION : 1 m in front at height of 1.5 m 40 NC-40 Approximate 30 minimum audible limit for NC continuous noise Overall Frequency at center of sound pressure band (Hz) MODEL : SOUND LEVEL : 62.0 db (A) (Quiet mode 59.0) CONDITION : 1 m in front at height of 1.5 m NC-60 NC-50 NC-60 NC NC-40 Approximate 30 minimum audible limit for NC-30 continuous noise 20 Overall Frequency at center of sound pressure band (Hz) Sound pressure level (db) (0dB = μbar) MODEL : SOUND LEVEL : 62.0 db (A) (Quiet mode 59.0) CONDITION : 1 m in front at height of 1.5 m NC-60 NC NC-40 Approximate 30 minimum audible limit for NC-30 continuous noise 20 Overall Frequency at center of sound pressure band (Hz)
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
Appendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and
1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units
SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections
Air Conditioning For Large Buildings
Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE
AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this
Air Conditioning for Small and Medium-size Buildings
Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units
Split units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
AIR CONDITIONING and HEAT PUMP PRODUCTS
AIR CONDITIONING and HEAT PUMP PRODUCTS February 2015 The History of Panasonic Air Conditioning The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73
MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System
VRF Variable Refrigerant Flow System CATALOGUE HEAT PUMP & HEAT RECOVERY for Europe Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years.
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED
Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,
Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV
Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS 2011 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total sales
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS 2011 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
Commercial Gas Heat Pump - VRF
SANYO GHP Introduction Commercial Gas Heat Pump - VRF 01.12.2011 Agenda 1. SANYO GHP History 2. SANYO GHP Range 3. GHP Market Position 4. 2-WAY 5. GHP Power 6. 3-WAY 7. EER/COP 8. Water Heat Exchanger
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
Air conditioners Heating & Cooling
Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu
SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2
SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A
More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System
For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW
utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger
LOCAL AIR-CONDITIONERS
LOCAL AIR-CONDITIONERS Local air-conditioners Compact Design Split Design Compact Air-Conditioner Quality with systems REMKO THE CUSTOMER-ORIENTED SYSTEM SUPPLIER FOR THE WHOLE YEAR THROUGH From the development
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump
SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB
Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)
room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
Multi Air Conditioning System for Buildings
Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :
TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Aerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
TWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Engineering Specifications
Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU
DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3
DM13-01.01.01en Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 Contents Part 1 General Information... 1 Part 2 Selection
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE
Order No. PHAAM1003090C3 Outdoor Unit CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Air Conditioner Please file and use this manual together with the service manual for Model No. CS-E7LKEW CU-E7LKE CS-E7LKEW
DESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS
New Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT
UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers
NEW VRF SYSTEMS // HEATING AND COOLING SYSTEMS NEW 2012-2013
NEW VRF SYSTEMS // HEATING AND COOLING SYSTEMS NEW 2012 2012-2013 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
