Cserver 1180 / 1125. Basic Operating Manual



Similar documents
Using GIGABYTE Notebook for the First Time

Using GIGABYTE Notebook for the First Time

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Using GIGABYTE Notebook for the First Time

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

Using GIGABYTE Notebook for the First Time

HQP-1072 Series System User Guide

External Storage 200 Series. User s Manual

TS500-E5. Configuration Guide

Using GIGABYTE Notebook for the First Time

Raritan LCD KVM Console (T1700/T1900)

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Raritan LCD KVM Console (T1700/T1900)

SPC-530. Rackmount Server PC. User's Manual

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

Tyan Computer. Transport PX22. Service Engineer s Manual

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

E2437. Motherboard. Troubleshooting Guide Q & First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved.

ACT-DASR101 Disk Array Series products

System Release Notes Express5800/320LB System Release Notes

ARAID 3500 / S3500 User s Manual

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

Using GIGABYTE Notebook for the First Time

USER S MANUAL.

XL-RAID-SATA Data Backup System. User s Guide

Using GIGABYTE Notebook for the First Time

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

Chapter 5 Cubix XP4 Blade Server

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

FT Server. Fault Tolerant Server Platform. Instruction Manual

2 Bay FireWire 800/400/USB RAID Solution RAID 0, RAID 1, & JBOD. User Manual

Recovering from a Hard Drive Failure

StorTrends 3400 Hardware Guide for Onsite Support

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

2» 10» 18» 26» PD »

USB External Hard Disk Drive

Single-bay NAS Server

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

Using AORUS Notebook for the First Time

Infinity C Reference Guide

Quick Start Turning on the Tablet PC for the First Time

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

McAfee Data Loss Prevention

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, v1.0

Genesi Pegasos II Setup

82341C HPIB Installation and Troubleshooting Windows 95 and Windows NT CE, GC, LC and A/D ChemStation, Version A.05.0x and A.06.0x

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

ReadyNAS Duo and NV+

BounceBack Server Solution Reference Guide

English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

3.5 EXTERNAL NETWORK HDD. User s Manual

OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES

Chapter 6 The BIOS Setup Program

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Version : 1.0. SR3620-2S-SB2 User Manual. SOHORAID Series

Getting Started. rp5800, rp5700 and rp3000 Models

ReadyNAS OS 6 Desktop Storage Systems

Intel Rapid Storage Technology

How To Set Up A Hard Disk Drive With A Rkd (Sr5650) And A Hard Drive (Srs5650-Wbs1/Sb2)

USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM

ITE RAID Controller USER MANUAL

Technical Support. Package Contents. CENTRIA WNDR4700/WNDR4720 Installation Guide

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Using RAID Admin and Disk Utility

Verbatim PowerBay 4-Bay RAID Multi-Interface Drive Version 1.00

Frontier DSL SelfConnect Guide

SOFTWARE INSTALLATION INSTRUCTIONS

LG External HDD Hard Disk Drive XG1

FUSION R400 RAID USB 3.0

How To Play Your Hard Disk Drive On A Mini Hard Disk (Ios) Or Usb (Miii) With A Hard Disk 2 (I2) Or Ios 2 (Mini Usb) With An External Hard Drive (Mini) Or Mini

Using GIGABYTE Notebook for the First Time

Image Backup and Recovery Procedures

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

DF to-2 SATA II RAID Box

HL2170W Windows Network Connection Repair Instructions

Ultra Thin Client TC-401 TC-402. Users s Guide

NNAS-D5 Quick Installation Guide

Promise FastTrak 100-Lite RAID Controller

Ultra ATA 133 RAID PCI Pro

Serial ATA to Serial ATA

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

Using GIGABYTE Notebook for the First Time

Sample of Hardware Equipment Acceptance Form

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

Amcrest 960H DVR Quick Start Guide

Cisco NAC Appliance Hardware Platforms

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

Operating Instructions

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

LCD Drawer User Manual

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Transcription:

Cserver 1180 / 1125 Basic Operating Manual Version 1.0 2002 PCW Microsystems, Inc. 1

Cserver 1180 / 1125 Basic Operating Manual Before You Begin Check the box contents! Cserver 1180 / 1125 package should contain the following:?? Cserver 1180 Computer Unit?? Cserver 1180 Basic Operating Manual?? One set of L-Bracket for rack cabinet rear mounting.?? One 110V or 220V power cord.?? Software Driver CD-ROM or Disk Sets If any of the above items are missing, please contact PCW Microsystems, Inc. (www.rackmount.com) for replacements before continuing with the installation process. Hardware Requirements Single Computer Connection Cserver1180 requires a computer with following ports to operate:?? A Standard VGA Monitor?? A 6-pin mini-din PS/2 Keyboard?? A 6-pin mini-din PS/2 Mouse 2

WARNING: Do not turn on the power to Cserver1180/1125, if the unit shows signs of crack or damage. Some circuitry in the Cserver1180/1125 may continue to operate even though the front panel power switch is off. For your safety, never open the Cserver1180/1125 with power cord connected to the outlet. Repair service should be performed by qualified service personnel. Read and adhere to all warnings, cautions, and notices in this guide and the documentation supplied with this unit. If the instructions for the Cserver1180/1125 are inconsistent with these instructions or the instructions for accessory modules, contact PCW Microsystems, Inc (www.rackmount.com) to find out how you can ensure that your Cserver1180/1125 unit meets safety and regulatory requirements. Basic Csever1180/1125 Features Cserver 1180 / 1125 1U rackmount server offers the following features:?? Operating System independent RAID-1 Hardware Controller (Disk Mirror)?? Two Hot-Swap ATA-100 EIDE Harddisks?? Single or Dual Pentium III Processors?? On-Board Video Port?? On-Board LAN Port(s) (Single or Dual) 3

System Diagram Csever1180 / 1125 consist of two removable EIDE hard disk trays, a 24x CDROM reader and a 1.44MB floppy drive. The removable EIDE hard disk tray can be pullout during power-on operation. This feature is called hot-swap. There are two reset-switches below the HDD1 and HDD2 label. The reset-switches are for RAID-1 controller s hard disk failure alarm and system reset. There is a server on/off switch control located on the front panel of the unit. Please keep in mind that the front on/off switch is useless, if the rear master power switch is not turned on. At the back (rear) of the unit, there is a master power switch for the power supply unit. In addition, there are PS2/mouse, PS/2 keyboard, 100Mpbs Ethernet and video ports located at the back of the server unit. 4

Cserver 1180 / 1125 Front Indicate Lights Access The system hard disk HDD1 or HDD2 is accessing data (Reading/Writing) Rebuild Initial disk rebuild process. The rebuild light shows that either a brand new hard disk has been inserted or the data stored in HDD1 or HDD2 is inconsistent. Fail The fail light indicates that the RAID-1 controller has marked one of the hard disk as bad or failed. However, this does not necessary indicate a bad or failed hard disk. If this happens, you will need to use hard disk low-level formatting software supplied by the hard disk manufacturer(s) to wipe out the bad/failed disk information written on the outer sector of the disk. HDD1 / HDD2 Shows the status of hard disk trays. Alarm Reset The alarm reset button turn-off the internal RAID-1 alarm when one of the hard disk failed. Sys Reset This is the system-reset button. 5

Basic Operation Cserver1180/1125 has a built-in hardware RAID-1 controller. After powering on the unit, the RAID-1 controller will automatically mirror both DISK 1 and DISK 2 hard disks and checking for data consistency. The mirroring process will take few hours depending on the size of the installed IDE hard disks. During the initial disk mirroring (initial disk rebuild) process, you may install any of your favorite operating system. You will see the Rebuild indicator lights up during the initial disk mirroring process. During the initial disk rebuild process, you may:?? Install operating system(s)?? Install software drivers for your O.S.?? Format the disk (you will only see one hard disk in your formatting utility)?? Reset or soft reboot the server during the software installation During the initial disk rebuild process, you may not:?? Pull-out any of the removable hard disk tray from the server bay?? Shut-down the server unit WARNING: Note: Shut-down the server unit during the initial disk build process will force the RAID-1 controller to mark the system disks as bad or failed units. If this happens, you will need to use the hard disk lowlevel formatting software supplied by the hard disk manufacturer(s) to wipe out the bad/failed disk data written on the outer sector of the disk. After the unit successfully synchronized (sync) both IDE hard disks, you may:?? Only pullout ONE of the removable hard disk trays from the server bay. After pulling out the removable hard disk trays and re-insert the removable hard disk trays into the bay, the Rebuilt indicate light will turn on. You must wait few hours until the Rebuilt light is off, before pullout any of the hard disk trays from the server bays.?? Re-install Operation System?? Powering down the unit WARNING: Note: Pulling-out any of the removable hard disk trays from the server bay will force the RAID-1 controller to rebuild the disk (Mirroring) on the tray. At this point, if attempt to pull-out a second hard disk tray from the server bay, the entire server will crash and render both disks as failed or bad disks. If this happens, you will need to use the hard disk low-level formatting software supplied by the hard disk manufacturer(s) to wipe out the bad/failed disk data written on the outer sector of the disk. 6

Removing hard disk tray from the server drive bay 1. Use a pen to pullout (fish-out) the disk tray handle bar. 2. Slowly lift the handle bar out of the drive bay. 3. Grab the disk tray handle bar and pullout the disk unit out of the drive bay. Done. 7

Insert hard disk tray into the server bay 1. Slowly slide the hard disk tray into the server s drive bay. Grab the handle bar and slowly insert the hard disk tray unit into the server drive bay. 2. Use thumb to push the handle bar into the bay until the tray is firmly seated. 3. Done 8

Basic Troubleshooting The following guide is for reference purpose only. Contact a PCW Technical Support Representative for additional help. Symptoms Possible Cause(s) Solution Both HDD1 / HDD2 Fail indicate lights are on and the server unit is beeping. You might have accidentally pullout both HDD1 tray and HDD2 tray, without given adequate time for the RAID-1 controller to rebuild the disk(s). You will need hard disk lowlevel formatting software supplied by the hard disk manufacturer(s) to wipe out the bad/failed disk data written on the outer sectors of the disk. One of the hard disk s Fail indicates light is on and the server unit is beeping. The Rebuild indicates light is always on for hours. The server cannot detect the hard disk. One of the server hard disk showed Fail. Is this really a defective drive? I installed a new IBM IDE hard disk, but the server cannot detect the hard disk(s). I powered up the server. But, after few minutes the unit rebooted for no reason. One of the hard disk might have failed. One of the hard disk is not synchronized with the other due to recent hard disk tray pullout or server power outages. The hard disk removable tray(s) might not have been firmly inserted into the drive bay. You might have accidentally pullout the hard disk tray repeatedly from the drive bay while the server was under the Rebuild mode. One of the hard disk is not properly setup as the default master. The power supply s 115V/220V switch located inside the unit was incorrectly set. Replace the defective hard disk with a brand new hard disk. The size of the new hard disk must be equal or larger than the original hard disk size. Wait for up to 24 hours for the server to rebuild the hard disks. Push the hard disk removable tray back into the drive bay again until it is firmly secured. You need to download software such as IBM s Drive Fitness Test (Version 3.0) or Disk Manager to wipe out the data on the hard disk. http://www.ibm.com or http://www.wdc.com Please set up both hard disks on the removable trays to factory default master setting. Need to call PCW Microsystems for support. 9