Amendments to the 2012 INTERNATIONAL FIRE CODE



Similar documents
Georgia State Amendments to the International Fire Code (2012 Edition)

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

Inspection, Testing and Maintenance

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

Overview of Hotel Fire Safety Requirements

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Fire Alarm Systems Requirements by Occupancy Type

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

Bold items are particular to the City of Euless

CHAPTER 9 FIRE PROTECTION SYSTEMS

Errata has been identified as follows:

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

Metropolitan Washington Airports Authority Office of Public Safety Fire & Rescue Department. Fire Code Enforcement Division

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

Fire Alarm and Protection Impairment Policy and Procedures

Winnipeg Fire Department Fire Prevention Branch

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

LICENSE CATEGORIES. (2) A demolition contractor class II may demolish any building not more than three stories in height.

TOWN OF ORO VALLEY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE, 2012 EDITION

Environment of Care Fire Safety Management Plan 2014

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

946 CMR: MASSACHUSETTS DEVELOPMENT FINANCE AGENCY 946 CMR 7.00: DEVENS REGIONAL ENTERPRISE ZONE FIRE AND POLICE RULES

Important Ontario Fire Code Information for Building Owners in the City of Windsor

FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE

Casa Grande Development Center Effective August 1, 2008 Building & Fire Codes

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Fire Watch. Fire safety systems may not be deactivated in whole or in part for any reason other than for repairs or hot work.

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

South Carolina DSS. "Records and Reports" 7-12

Minnesota State Department of Public Safety

Fire and Emergency Medical Services (EMS) Responders

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Division 21. Fire Suppression

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

TORONTO MUNICIPAL CODE CHAPTER 470, FIRE SAFETY BOXES. Chapter 470 FIRE SAFETY BOXES

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rules

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

NEW YORK CITY FIRE DEPARTMENT

Code Compliance Guideline: Swimming Pool Chemicals

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

2016 BUILDING PERMIT FEES*

Fire Alarm System Plans Review Checklist Property location Date of Review

The University of Texas at San Antonio Environmental Health, Safety and Risk Management

NOW THEREFORE BE IT ORDAINED by the City Council of the City of

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

FIRE-FIGHTING DESIGN BRIEF REPORT

Decree of the Ministry of the Environment. on fire safety of garages

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

THE CORPORATION OF THE CITY OF MISSISSAUGA FIRE & EMERGENCY SERVICES FEES AND CHARGES BY-LAW

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

OVERVIEW SCOPE DEFINITIONS

City of Riverside Building & Safety Division Phone: (951)

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

STCC Contractor/Vendor Rules and Regulations

Note: Fire Cause and Arson Investigation are covered in Criterion 5D.

How To Install A Carbon Monoxide Detector

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

Module 4, Lesson 12 Fire Alarm Systems

Columbia University Medical Center. Policies and Procedures for Shutdowns and Modifications to Fire Alarm Systems and Fire Suppression Systems

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

General Fire Code Requirements Within Commercial Tenant Spaces

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

STATE OF WISCONSIN Department of Safety and Professional Services

ORDINANCE NO

SECTION FIRE ALARM AND DETECTION SYSTEM

The Mission Critical Fire Protection Experts

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Design & Construction Standards, Revised January

CHAPTER 67.2 RESIDENTIAL BUILDING CODE

Transcription:

Amendments to the 2012 INTERNATIONAL FIRE CODE 2012 Edition, International Fire Code. Section 101.1 Amend to read as follows. 101.1 Title. These regulations shall be known as the Fire Code of the City of Black Hawk, hereinafter referred to as this code. 2012 Edition, International Fire Code. Section 101.2.1 Amend to add the following appendices. 101.2.1 Appendices. Provisions in the appendices shall not apply unless specifically adopted. The following appendices and NFPA standards shall be adopted and made part of the Fire Code of the City of Black Hawk. Appendix B, Fire Flow Requirements for Buildings, Appendix C, Fire Hydrant Locations and Distribution, Appendix D, Fire Apparatus Access Roads, and Appendix I, Fire Protection Systems Noncompliant Conditions as published by the International Code Council (ICC) are specifically adopted and made a part of the Fire Code of the City of Black Hawk. 2012 Edition, International Fire Code. Amend to add the following Section 103 Black Hawk Fire Department, Division of Fire Prevention. 103.2 Appointment. The fire code official shall be appointed by the Black Hawk Fire Chief. 2012 Edition, International Fire Code, Add to Section 903.2 Section 903.2 Where required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in this section. Automatic sprinkler systems shall be provided throughout buildings and structures of the following building groups. Group A-1, Group A-2, Group A-3, Group A-4, Group B, Group E, Group F-1, F-2, Group H, Group I, Group M, Group R-1, Group R-2, Group R-3, Group R-4, Group S-1, and Group S-2 where one of the following conditions exist. 1. The fire area exceeds 2500 square feet. 2. The fire area has an occupant load of 100 or more. 3. The fire area is located on a floor area other than the level of exit discharge. All Group H and I occupancies shall be provided with an approved automatic sprinkler system regardless of size. Fire sprinkler systems shall meet the requirements of NFPA 13 or 13R and the requirements of this code.

2012 Edition, International Fire Code. Add Section 901.4.7, Modifications: 901.4.7 Modifications. No person shall remove or modify any fire protection system installed or maintained under the provisions of this code without approval by the Fire Chief or the Fire Code Official. 2012 Edition, International Fire Code, Section 903.2.1 thru Section 903.2.10.1 Delete in their entirety. The remainder of section 903.2 not affected by the above shall remain unchanged. 2012 Edition, International Fire Code, Add Section 903.2.1 Group A-2 Casino. An automatic sprinkler system shall be provided throughout every building containing Group A-2 Casino occupancy regardless of size. Such sprinkler system shall be provided throughout the entire building including the casino, offices, multipurpose areas, storage areas, parking garages, hotels and other spaces contiguous and accessory to the building. 2012 Edition, International Fire Code. Amend Section 905 Standpipe Systems. Section 905.3 Required Installations. Standpipe systems shall be installed where required by Sections 905.3.1 through 905.3.6 and in the locations indicated in Sections 905.4, 905.5 and 905.6, Only Class I Standpipe systems with 1 ½ x 2 ½ National Hose adaptors as determined by the Authority Having Jurisdiction shall be installed. Standpipe systems are permitted to be combined with automatic sprinkler systems. Systems. Add Section 907.2.1.1 Group A-2 Casino. An automatic and manual fire alarm system shall be installed in accordance with the most current edition of NFPA 72 and the provisions of this code throughout every building containing a casino regardless of size. Such fire alarm systems shall be provided throughout the casino and in offices, stages, storage areas, parking garages and on each elevator floor landing of a parking garage, hotels and other accessory spaces contiguous and accessory to such casino. Exception: New parking garages that are protected by an automatic sprinkler system. Systems. Amend and change 907.2.1.1 to 907.2.1.2, 907.2.1.2 to 907.2.1.3. Systems. Delete 907.2.1 Exception.

2012 Edition, International Fire Code, Add Section 507.5.3.1 and 507.5.3.2 507.5.3.1 Fire mains. Fire mains and appurtenances shall be sized to accommodate the calculated fire flow but shall not be less than 6 inches (152 mm) in diameter. Dead-end fire mains shall not be less than 8 inches (203 mm) in diameter unless calculations determine otherwise and authorized by the authority having jurisdiction. 2012 Edition, International Fire Code. Amend Section 403 Public Assemblages and Events. Add Section 403.1.2 Required Fire Watch Permit FIRE WATCH PERMIT 403.1.2 When required. A fire watch permit shall be required: 1. When required by other sections of this code. 2. When the Fire Code Official deems a condition essential for public safety. 3. When the Fire Code Official determines that conditions may result in a rekindle. 4. When the fire alarm system is off-line or out of service for repairs or maintenance. 5. When the fire suppression system is off-line or out of service for repairs or maintenance. 6. Fire Watch Permits shall be valid for a period not to exceed 24 hours unless otherwise authorized by the fire chief or the fire code official. 403.1.4 Financial responsibility. The property owner, the tenant or occupant in control of the premises shall be responsible for the cost of providing a fire watch. 403.1.5 Qualifications. Personnel assigned to fire watch duties shall possess the following minimum qualifications: 1. Shall be at least 18 years of age. 2. Shall be able to speak, read, and understand English. 3. Shall be capable of executing the duties and responsibilities as specified in Section 403.1.7. 4. Shall be capable of operating a mobile telephone and/or portable radio. 5. Shall be capable of walking the assigned watch area.

403.1.6 Number and hours. The Fire Code Official shall specify the number of fire watch personnel required and the hours during which they must be present based on the conditions and size of the facility. 403.1.7 Duties and responsibilities. Fire watch duties and responsibilities include, but are not limited to the following: 1. Know the address of the facility being watched. 2. Shall be equipped with a mobile telephone that can be used to contact 9-1-1 or a portable radio that can be used to communicate with a constantly attended security/communications center. 3. Continuously make rounds and monitor all assigned areas. 4. Immediately report any sign of smoke, fire or other emergency to 9-1-1 or to the security/communications center. 5. In the event of any sign of fire or smoke shall activate the fire alarm system when the building is equipped with such a system or notify those present to evacuate the building or area. 6. Shall assist with the evacuation of people present in the area. 7. Keep a fire watch log that includes the following information: Identifies the building or area by name and address that is under watch. The date and time each round or tour is completed, plus comments on what was observed. Each entry shall contain the name and signature of the person conducting the watch. Fire watch logs shall be immediately accessible for review by the Fire Code Official. A copy of the fire watch log shall be submitted to the Black Hawk Fire Department, Fire Prevention Division when the watch is concluded. Fire watch personnel shall not be assigned additional duties during their fire watch tour.

2012 Edition, International Fire Code, Section 607, Elevator operation, maintenance, and fire service keys. Add Section 607.5.1.1 Elevator Switch Keys. 607.5.1.1 Elevator Switch Keys: The key switches required for all elevators in a building shall be operable by the same key. The keys shall comply with the requirements determined by the authority having jurisdiction. There shall be a key for each switch provided. All elevator switch keys shall be kept on the premises in a location specified by the authority having jurisdiction. The keys shall not be accessible to the public.