1 Casa Grande Development Center Effective August 1, 2008 Building & Fire Codes International Fire Code, 2003 Edition Appendix B Fire Flow Requirements for Buildings Appendix C Fire Hydrant Locations and Distribution Appendix D Fire Apparatus Access Roads Appendix E Hazard Categories Appendix F Hazard Ranking Appendix G Cryogenic Fluids Weight & Volume Equivalents Appendix H Special Fire Risk Areas (ii) City of Casa Grande Amendments to the IFC International Code Council Electrical Code, 2003 Edition International Residential Code, 2003 Edition Appendix A Sizing and Capacities of Gas Piping Appendix B Sizing of Venting Systems Appendix C Exit Terminal of Mechanical Draft Appendix D Existing Appliance Installation Appendix G Swimming Pools, Spas, and Hot Tubs Appendix H Patio Covers Appendix J Existing Buildings and Structures Appendix K Sound Transmission (ii) City of Casa Grande Amendments to the IRC International Building Code, 2003 Edition Appendix C Agricultural Building Appendix I Patio Covers (ii) City of Casa Grande Amendments to the IBC International Fuel Gas Code, 2003 Edition (ii) City of Casa Grande Amendments to the IFGC International Mechanical Code, 2003 Edition (ii) City of Casa Grande Amendments to the IMC International Plumbing Code, 2003 Edition (ii) City of Casa Grande Amendments to the IPC National Electrical Code, 2005 Edition (ii) City of Casa Grande Amendments to the NEC 2005
2 City of Casa Grande Amendments to International Fire Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
3 CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL Title. These regulations shall be known as the Fire Code of (NAME OF JURISDICTION), hereinafter referred to as this code is amended to read: These regulations shall be known as the Fire Code of Casa Grande, hereinafter referred to as this code Appendices. Provisions in the appendices shall not apply unless specifically adopted is amended to read: Appendices. The following appendices are adopted as part of this code by the City of Casa Grande: Appendices B, C, D, E, F, G, and Appendix H as added. Other provisions in the appendices shall not apply. SECTION 102 APPLICABILITY Change of Use or Occupancy. The provisions of the International Existing Building Code shall apply to all buildings undergoing a change of occupancy is amended to read: Change of Use or Occupancy. All changes of use or occupancy shall comply with the provisions of the International Existing Building Code and shall be coordinated with the Fire Chief prior to issuance of a temporary or permanent Certificate of Occupancy Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 and such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between the provisions of this code and the referenced standards, the provisions of this code shall apply is amended to read: Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 as amended. Such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between the 2
4 provisions of this code and the referenced standards, the provisions of this code shall apply. SECTION 103 DEPARTMENT OF FIRE PREVENTION Appointment. The fire code official shall be appointed by the chief appointing authority of the jurisdiction; and the fire code official shall not be removed from office except for cause and after full opportunity to be heard on specific and relevant charges by and before the appointing authority is amended to read: Appointment. The fire code official shall be appointed by the chief appointing authority of the jurisdiction. SECTION 105 PERMITS Permits required. Permits required by this code shall be obtained from the fire code official. Permit fees, if any, shall be paid prior to issuance of the permit. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official is amended to read: Permits required; fees. It shall be unlawful for any person, firm, or corporation to use a building or premises or engage in any activities for which a permit is determined to be required by the Fire Chief without having first obtained such permit. The fees for fire code permits shall be established by the City of Casa Grande Consolidated Fee Schedule. Permit fees shall be paid prior to issuance of the permit. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire code official is added as follows: Work commencing before permit issuance; fees. Any person who commences any work on an item requiring a fire code permit before obtaining the necessary permits shall be liable for the cost of the permit, along with an additional assessment equal to the normal assessed permit fees Required construction permits. The fire code official is authorized to issue construction permits for work as set forth in Sections through is amended to read: Required construction permits. The fire code official is authorized to issue construction permits for work as set forth in Sections through
5 is added as follows: Fire apparatus access gates. A construction permit is required to install or modify both manual and automatic fire apparatus access gates and their appurtenances. This also includes gates for auxiliary access openings is added as follows: Access-controlled egress doors. A construction permit is required to install or modify the connection to the fire alarm system for access-controlled egress doors in accordance with Section is added as follows: Delayed egress locks. A construction permit is required to install to the fire alarm system for delayed egress locks in accordance with Section SECTION 106 INSPECTIONS is added as follows: Inspection requests. It shall be the duty of the holder of the permit or their duly authorized agent to notify the fire code official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that is required by this code is added as follows: Approval required. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the fire code official. The fire code official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or notify the permit holder or the agent wherein the inspection fails to comply with this code. Any portions that do not comply shall be corrected and such portion shall not be covered or concealed until re-inspected and authorized by the fire code official Concealed work. Whenever any installation subject to inspection prior to use is covered or concealed without having first been inspected, the fire code official shall have the authority to require that such work be exposed for inspection is amended to read: Concealed work. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes. Whenever any installation subject to inspection prior to use is covered or concealed without having first been inspected and approved, the fire code official shall have the authority to require that such work be exposed for inspection. Neither the fire code official nor the jurisdiction shall be liable for expense entailed in the removal 4
6 or replacement of any material required to allow inspection and all expenses shall be incurred by the permit applicant is added as follows: On-site construction documents. One set of code official approved construction documents shall be on the job site for each inspection. Failure to have approved construction documents on site shall result in canceling the inspection and is subject to assessment of a fee in accordance with the adopted consolidated fee schedule of the City of Casa Grande. SECTION 111 STOP WORK ORDER Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine of not less than [AMOUNT] dollars or more than [AMOUNT] dollars is amended to read: Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable for a fine of not less than $ or more than $ per occurrence. 5
7 CHAPTER 2 DEFINITONS SECTION 202 GENERAL DEFINITIONS 202 is amended to add the following definitions: STANDBY PERSONNEL. Qualified fire service personnel, whether City employees or otherwise, as reasonably approved by the Fire Chief. When utilized, the number required shall be as directed by the Fire Chief. Charges for utilization of city employees as standby personnel shall be as set forth in the City of Casa Grande Consolidated Fee Schedule. SPECIAL FIRE RISK AREA. Land which is covered with grass, grain, brush or forest, whether privately or publicly owned, which is so situated or is of such inaccessible location that a fire originating upon it would present an abnormally difficult job of suppression or would result in great or unusual damage through fire, or such areas designated by the Fire Chief. 202 is further amended as follows: Group I-1. This occupancy shall include buildings, structures or parts thereof housing more than 16 persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment that provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This group shall include, but not be limited to, the following: Alcohol and drug centers Assisted living facilities Congregate care facilities Convalescent facilities Group homes Half-way houses Residential board and care facilities Social rehabilitation facilities A facility such as the above with five or fewer persons shall be classified as Group R-3 or shall comply with the International Residential Code. A facility such as above, housing at least six and not more than 16 persons, shall be classified as Group R-4. Group I-1 is amended to read: Group I-1. This occupancy shall include a building or part thereof housing more than 10 persons on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This group shall include, but not be limited to the following: residential board and care facilities, assisted living facilities, half-way houses, group homes, congregate care faculties, social rehabilitation, alcohol and drug centers and convalescent 6
8 facilities. A facility such as the above with five or fewer persons shall be classified as Group R-3. A facility such as above, housing at least six and not more than 10 persons shall be classified as Group R R-3 Residential occupancies where the occupancies are primarily permanent in nature and not classified as R-1, R-2, or Group I and where buildings do not contain more than two dwelling units, or adult and child care facilities that provide accommodations for five or fewer persons of any age for less than 24-hours. Adult and child care facilities that are within a single-family home are permitted to comply with the International Residential Code. R-3 is amended to read: R-3 Residential occupancies where the occupants are primarily permanent in nature and not classified as R-1, R-2, R-4 or Group I and where buildings do not contain more than two dwelling units or adult and child care facilities not located in a single-family home that provide accommodations for five or fewer persons of any age for less than 24 hours. Adult and child care facilities that are within single-family home are permitted to comply with the International Residential Code. R-3 Residential Care/Assisted Living Facilities occupancies in existing structures with five or fewer occupants excluding staff shall meet the following requirements: 1. Inter-connected hard wired Smoke detectors shall be installed in all livable areas. 2. Posted evacuation map and emergency procedures. 3. Portable fire extinguishers in accordance to Casa Grande Fire Code R-4 Residential occupancies shall include buildings arranged for occupancy as Residential Care/Assisted Living Facilities including more than five but not more than 16 occupants. Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3 except for the height and area limitations provided in Section 503 of the International Building Code or shall comply with the International Residential Code. R-4 is amended to read: R-4 Residential occupancies shall include buildings arranged for occupancy as Residential Care/Assisted Living Facilities including more than five but not more than 10 occupants, excluding staff. Such occupancies shall meet the following requirements: 1. An automatic fire sprinkler system installed in accordance with the City of Casa Grande Fire Code. 7
9 2. Smoke detectors shall be installed in all livable areas. 3. Posted evacuation map and emergency procedures. 4. Portable fire extinguishers in accordance to Casa Grande Fire Code. Exceptions: 1. State licensed residential care/assisted living facilities in which all of the care recipients are capable of self-preservation and responding to an emergency situation without assistance from another person. 2. R-4 occupancies existing before August 1, 2008, shall not be required to install an automatic fire sprinkler system unless there is a change of occupancy classification due to an increase in the number of licensed occupants. 8
10 CHAPTER 3 GENERAL PRECAUTIONS AGAINST FIRE SECTION 302 DEFINITIONS is amended to add the following definition: FORCED AIR CURTAIN DESTRUCTOR. A forced air pit incinerator that is utilized for the purpose of disposal of waste or vegetative debris. SECTION 307 OPEN BURNING AND RECREATIONAL FIRES is added as follows: Forced air curtain destructor. A forced air curtain destructor requires a permit and shall not be conducted within 500 feet of any dwelling. Conditions which could cause a fire to spread within 50 feet of a structure shall be eliminated prior to ignition. SECTION 308 OPEN FLAMES Open-flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated on combustible balconies or within 10 feet (3048 mm) of combustible construction. Exceptions: 1. One- and two-family dwellings. 2. Where buildings, balconies and decks are protected by an automatic sprinkler system is amended to read: Open-flame cooking devices. Charcoal burners, portable barbecues and other open flame devices shall not be operated on combustible balconies or within 10 feet (3048 mm) of combustible construction. Exception: One and two-family dwellings. SECTION 311 VACANT PREMISES Fire protection. Fire alarm, sprinkler and standpipe systems shall be maintained in an operable condition at all times. Exceptions: 1. When the premises have been cleared of all combustible materials and debris and, in the opinion of the fire code official, the type of construction, fire separation distance and security of the premises do not create a fire hazard. 9
11 2. Where buildings will not be heated and fire protection systems will be exposed to freezing temperatures, fire alarm and sprinkler systems are permitted to be placed out of service and standpipes are permitted to be maintained as dry systems (without an automatic water supply) provided the building has no contents or storage, and windows, doors and other openings are secured to prohibit entry by unauthorized persons is amended by deleting exceptions 1 and 2. 10
12 CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL is added as follows: Finished Drawings. Upon completion of construction and prior to issue of a Certificate of Occupancy, unless the same would constitute a demonstrated hardship to the applicant, a copy of finished drawings shall be supplied to the Fire Department in an electronic format acceptable to the Fire Department. SECTION 502 DEFINITIONS is amended to add the following definitions: PREEMPTION DEVICE. A listed and approved electronic device that receives a signal compatible with transmitters on emergency vehicles and that is used to automatically open or close fire apparatus access gates and all traffic control devices. FIRE FLOW. The flow rate of a water supply, measured at 20 psi residual pressure that is available for firefighting. SECTION 503 FIRE APPARATUS ACCESS is added as follows: Temporary Fire Department access. Temporary Fire Department access shall comply with Fire Department requirements. No construction on any project may proceed until such time as the fire protection plan for the project has been approved by the fire code official Security gates The installation of security gates across a fire apparatus access road shall be approved by the fire chief. Where security gates are installed, they shall have an approved means of emergency operation. The security gates and the emergency operation shall be maintained operational at all times is as amended as follows: The installation of security gates across a fire apparatus access road shall be approved by the fire chief. Where security gates are installed, they shall have a preemption device and a key override switch for entry and exit. The security gates and the emergency operation shall be maintained operational at all times. 11
13 SECTION 508 FIRE PROTECTION WATER SUPPLIES Fire flow. Fire flow requirements for buildings or portions of buildings and facilities shall be determined by an approved method is amended to read: Fire flow. Fire flow requirements for buildings or portions of buildings and facilities shall be determined by an approved method and in accordance with Appendix B as amended. The Fire Chief may require an approved independent third party individual or firm to conduct a fire flow test prior to issuance of a Certificate of Occupancy is added as follows: Fire Flow Verification. The Fire Chief may require all new buildings or structures to provide fire flow verification according to the requirements in Appendix B as amended. Verification shall be conducted by an approved separate third party certifying the fire flow data Fire hydrant systems. Fire hydrant systems shall comply with Sections through is amended to read: Fire hydrant systems shall comply with Sections through is added as follows: Water Service Maps. Each water service provider serving areas within the City, whether municipal or private, shall provide the fire department with three sets of maps identifying the location of water tanks, distribution lines, service lines, and fire hydrants within the service area of the water provider. The maps shall be submitted on or before December 31, of each year, and shall be updated by the water service provider as new fire hydrants are installed is added as follows: Fire Hydrant Color. All fire hydrants shall have aboveground barrels painted with a prime coat plus two coats of OSHA yellow paint. The tops and nozzle caps shall be painted with the following capacity-indicating color scheme in accordance with NFPA 291: Light blue Class AA Rated capacity of 1500 gpm (5680 L/min) or greater Green Class A Rated capacity of gpm ( L/min) Orange Class B Rated capacity of gpm ( L/min) Red Class C Rated capacity of less than 500 gpm (1900 L/min) For rapid identification at night, the capacity colors shall be of reflective-type paint. 12
14 is added as follows: Hydrant Reflective Markers. All fire hydrants and Fire Department Connections shall be clearly identified by installation of reflective blue markers as specified by the Fire Chief is added as follows: Fire Protection Water Supply. The water system is required to be looped with a minimum of two separate connections under the following conditions: 1. Dead end water line exceeds 100 for 6 lines or 400 for 8 lines. 2. Water lines serve a building over 52,000 sq. ft. (40,000 sq. ft. when used for any amount of high-piled storage). 3. Water lines serve a building over two stories. 4. Water lines serve more then one commercial building. 5. Water lines serve over 30 single-family residential units. 6. Water lines serve a Group H occupancy. 7. As otherwise required by the fire marshal. Where two water connections are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the property or area to be served, measured in a straight line between the water connections. Where two water connections are required, they shall be made to separate water lines where possible is added as follows: Water distribution system failure notification. Each water service provider serving areas within the city, whether municipal or private, shall notify the Fire Department of any failure in their water distribution system, hydrant repair, main breaks, pump failures, or other interruptions of water supply that may affect water supply for fire control purposes as soon as possible in writing. A 30 day written notification is required for any fire line service that is to be discontinued due to financial lack of financial payment is added as follows: Out of service hydrants: Any hydrant that is out of service shall have an out of service ring located on the 4 inch supply and shall remain in place until the hydrant is operational and verified by the Fire Department is added as follows: Separate water supply. Water supply for Fire Protection systems shall not be combined with the domestic water supply. 13
15 CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 903 AUTOMATIC SPRINKLER SYSTEMS Group A-1. An automatic sprinkler system shall be provided for Group A-1 occupancies where one of the following conditions exists: 1. The fire area exceeds 12,000 square feet (1115 m2); 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than the level of exit discharge; or 4. The fire area contains a multi-theater complex is amended to read: Group A-1. An automatic sprinkler system shall be provided for Group A-1 occupancies where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet; 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than the level of exit discharge; or 4. The fire area contains a multi-theater complex Group A-3. An automatic sprinkler system shall be provided for Group A-3 occupancies where one of the following conditions exists: 1. The fire area exceeds 12,000 square feet (1115 m2); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than the level of exit discharge. Exception: Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge of the main entrance and exit is amended to read: Group A-3. An automatic sprinkler system shall be provided for Group A-3 occupancies where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet; 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than the level of exit discharge Group A-4. An automatic sprinkler system shall be provided for Group A-4 occupancies where one of the following conditions exists: 1. The fire area exceeds 12,000 square feet (1115 m2); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than the level of exit discharge. Exception: Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge of the main entrance and exit. 14
16 is amended to read: Group A-4. An automatic sprinkler system shall be provided for Group A-4 occupancies where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet; 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than the level of exit discharge Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 1. Throughout all Group E fire areas greater than 20,000 square feet (1858 m2) in area. 2. Throughout every portion of educational buildings below the level of exit discharge. Exception: An automatic sprinkler system is not required in any fire area or area below the level of exit discharge where every classroom throughout the building has at least one exterior exit door at ground level is amended to read: Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 1. Throughout all Group E fire areas greater than 5,000 square feet. 2. Throughout every portion of educational buildings below the level of discharge Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions exist: 1. Where a Group F-1 fire area exceeds 12,000 square feet (1115 m²); 2. Where a Group F-1 fire area is located more than three stories above grade; or 3. Where the combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230 m2) is amended to read: Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing Group F-1 occupancy where one of the following conditions exists: 1. Where a Group F-1 or area exceeds 5,000 square feet; 2. Where a Group F-1 or fire area is located more than three stories above grade; or 3. Where the combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 5,000 square feet. 15
17 Group I An automatic sprinkler system shall be provided throughout buildings with a Group I fire area. Exception: An automatic sprinkler system in accordance with Section or shall be allowed in Group I-1 facilities Group I is amended to read: An automatic sprinkler system shall be provided throughout buildings with a Group I fire area. Exceptions: 1. An automatic sprinkler system in accordance with Section or shall be allowed in Group I-1 facilities. 2. Daycare or childcare facilities occurring in single-family dwellings Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one of the following conditions exists: 1. Where a Group M fire area exceeds 12,000 square feet (1115 m2); 2. Where a Group M fire area is located more than three stories above grade; or 3. Where the combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230 m2) is amended to read: Group M. An automatic sprinkler system shall be provided throughout all buildings containing Group M occupancy where one of the following conditions exists: 1. Where a Group M fire area exceeds 5,000 square feet; 2. Where a Group M fire area is located more than three stories above grade; 3. Where the combined area of all Group M fire areas on all floors, including mezzanines, exceeds 5,000 square feet Group R An automatic sprinkler system installed in accordance with Section shall be provided throughout all buildings with a Group R fire area is amended to read: Group R. An automatic sprinkler system installed in accordance with Section shall be provided throughout all buildings with a Group R fire area. Exception: Automatic sprinkler systems shall not be required in R-3 occupancies of 5,000 square feet or less or R-4 occupancies that are exempted by Section 202 of this Fire Code. 16
18 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where one of the following conditions exist: 1. Where a Group S-1 fire area exceeds 12,000 square feet (1115 m2); 2. Where a Group S-1 fire area is located more than three stories above grade; or 3. Where the combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230 m2) is amended to read: Group S-1 and S-2. An automatic sprinkler system shall be provided throughout all buildings containing Group S-1 occupancy where one of the following conditions exists: 1. Where a Group S-1 or S-2 fire area exceeds 5,000 square feet; 2. Where a Group S-1 or S-2 fire area is located more than three stories above grade; or 3. Where the combined area of all Group S-1 or S-2 fire areas on all floors, including mezzanines, exceeds 5,000 square feet Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with the International Building Code, as follows: 1. Buildings two or more stories in height, including basements, with a fire area containing a repair garage exceeding 10,000 square feet (929 m2). 2. One-story buildings with a fire area containing a repair garage exceeding 12,000 square feet (1115 m2). 3. Buildings with a repair garage servicing vehicles parked in the basement is amended to read: Repair Garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with the International Building Code, as follows: 1. Buildings two or more stories in height, including basements, with a fire area containing a repair garage exceeding 5,000 square feet. 2. One-story buildings with a fire area containing a repair garage exceeding 5,000 square feet. 3. Buildings with a repair garage servicing vehicles parked in the basement Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 20,000 cubic feet (566 m3) shall be equipped throughout with an automatic sprinkler system in accordance with Section is amended to read: 17
19 Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 5,000 square feet shall be equipped throughout with an automatic sprinkler system in accordance with Section is added to read: Group B. An automatic sprinkler system shall be provided throughout buildings containing a Group B occupancy where one of the following conditions exists: 1. Where a Group B fire area exceeds 5,000 square feet (1115m 2 ) 2. Where a Group B fire area is located more than three stories above grade; or 3. The fire area has an occupant load of 300 or more Water supplies. Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section The potable water supply shall be protected against backflow in accordance with the requirements of this section and the International Plumbing Code is amended to read: Water supplies. Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section The potable water supply shall be protected against backflow in accordance with the requirements of this section and the International Plumbing Code. Automatic sprinkler systems water supply data for hydraulic calculations shall be based on a curve that is 90 percent of the available water supply curve as determined by flow test information Fire department connections. The location of fire department connections shall be approved by the fire code official is amended to read: Fire department connections. The fire department connection (FDC) shall be a separate approved line that connects to the sprinkler riser above the control valve. The location of fire department connections shall be approved by the fire code official and, unless shown to the fire code official to be adequate based on unique circumstances to the development, be located within 150 feet of a hydrant is added as follows: Existing buildings with fire walls. Any addition, alteration or repair causing any portion of the building or structure divided by a fire wall or partition to exceed 5000 square feet shall be required to conform to the requirements of Section for that fire area is added as follows: Protection and security of sprinkler systems. All fire sprinkler risers shall be secured and protected from the environment by being located inside the building or structure with a direct exterior access. 18
20 SECTION 904 ALTERNATIVE AUTOMATIC FIRE EXTINGUISHING SYSTEMS is added as follows: Additions, alterations, or repairs. Existing automatic fire extinguishing systems shall be upgraded to an approved fire-extinguishing system, installed throughout all portions of any commercial cooking system when there are additions or alterations to an existing non-compliant system. SECTION 907 FIRE ALARM AND DETECTION SYSTEMS is added as follows: Interior Tenant Notification. Interior Tenant Notification shall be provided when monitoring of the fire sprinkler system is provided. Group R occupancies are exempt from this requirement. Shell Buildings: 1 (one) horn strobe shall be installed and operational within the interior space prior to final. When demising walls are present, 1 (one) hornstrobe shall be installed for each space. Multi-story buildings shall require a minimum of 1 (one) horn-strobe per level. Tenant Improvements (Shell build-outs): 1 (one) horn-strobe shall be provided for each individual tenant. When a common area is provided serving multiple tenants, a minimum of 1 (one) horn-strobe in the common area shall be provided. These requirements may be increased based on occupancy type or if reasonably necessary for adequate protection of life safety as determined by the Fire Chief. 19
21 Chapter 45 REFERENCED STANDARDS The following NFPA standard reference numbers are deleted and replaced with the following: Deleted NFPA 13/1999 Installation of Sprinkler Systems Replaced NFPA 13/2002 Installation of Sprinkler Systems Deleted NFPA 13D/1999 Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes. Replaced NFPA 13D/2002 Installation of Sprinkler Systems in One-and Two- Family Dwellings and Manufactured Homes Deleted NFPA 13R/1999 Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height Replaced NFPA 13R/2002 Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height Deleted NFPA 72/1999 National Fire Alarm Code Replaced NFPA 72/2002 National Fire Alarm Code Delete the following NFPA publications: General Storage 231C 98 Rack Storage of Materials 231D 98 Storage of Rubber Tires Storage, Handling, and Processing of Magnesium Solids and Powders Production, Processing, Handling and Storage of Titanium Production, Processing, Handling and Storage of Zirconium Machining and Finishing of Aluminum and the Production and Handling of Aluminum Powders ADD the following NFPA publications Standard of the Fire Protection of Storage Standard for the Protection of Records Standard on Aircraft Hangers Standard for Combustible Metals, Metal Powders, and Metal Dusts 20
22 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS B105.2 Buildings other than one- and two-family dwellings: The minimum fire flow and flow duration for buildings other than one- and twofamily dwellings shall be as specified in Table B Exception: A reduction in required fire flow of up to 50 percent, as approved, is allowed when the building is provided with an approved automatic sprinkler system installed in accordance with Section or of the International Fire Code. Where buildings are also of Type I or II construction and are a light-hazard occupancy as defined by NFPA 13, the reduction may be up to 75 percent. The resulting fire flow shall not be less than 1,500 gallons per minute (5678 l/min) for the prescribed duration as specified in Table B B105.2 is amended to read: Buildings other than one-and two-family dwellings. The minimum fire flow and flow duration for buildings other than one-and two- family dwellings shall be as specified in Table B Exceptions: 1. All occupancies within the Central City and High School Redevelopment Districts as defined by Resolutions 2317, , and 2588 (to be known collectively as the Downtown Redevelopment District ) are exempt from the requirements of Table B All new construction and changes to occupancies within the Downtown Redevelopment District are also exempt from the requirements of Table B105.1 but shall be required to have a Fire Protection System equipped to handle the fire flows required by Table B A reduction in required fire flow of up to 50 percent, as approved, is allowed when the building is provided with an approved automatic sprinkler system installed in accordance with Section or of the International Fire Code. The resulting fire flow shall not be less than 1,500 gallons per minute for the prescribed duration as specified in Table B Where buildings are also of Type I or II construction and are light-hazard occupancies as defined by NFPA 13, the reduction may be up to 75 percent. The resulting fire flow shall not be less than 1,500 gallons per minute for the prescribed duration as specified in Table B In H occupancies, no reduction in required fire flow is allowed when the building is provided with an approved automatic sprinkler system installed in accordance with Section or of the International Fire Code. The resulting fire flow shall not be less than 1,500 gallons per minute for the prescribed duration as specified in Table B In buildings with high-piled storage, a reduction in required fire flow of up to 50 percent, as approved, is allowed when the building is provided with an approved automatic sprinkler system installed in accordance with Section or of the International Fire Code. The resulting 21
23 fire flow shall not be less than 1,500 gallons per minute for the prescribed duration as specified in Table B105.1 Note: The reduction allowed in these exceptions does not apply to the flow duration requirements in Table B105.1 or to the number and distribution of fire hydrants in Table C APPENDIX H SPECIAL FIRE RISK AREAS Appendix H relating to control and suppression in special Fire Risk Areas is added as follows: H100 Control and Suppression in Special Fire Risk Areas H101 Scope. The unrestricted use of grass-, grain-, brush- or forest-covered land in Special Fire Risk Area is a potential menace to life and property from fire and resulting erosion. Safeguards to prevent the occurrence of fire and provide adequate fireprotection to control the spread of fire which might be caused by recreational, residential, commercial, industrial, or other activities conducted in Fire Risk Areas shall be in accordance with Appendix H. H102 Clearance of Brush or Vegetation growth from Structures: Persons owning, leasing, controlling, operating or maintaining buildings or structures in, upon or adjoining Special Fire Risk Areas, and person owning, leasing or controlling land adjacent to such buildings or structures, shall at all times: 1. Maintain an effective firebreak by removing and clearing away flammable vegetation and combustible growth from areas with 30 feet (9144 mm) of such buildings or structures; Exception: Single specimens of trees, ornamental shrubbery or similar plants used as ground covers, provided that they do not form a means of rapidly transmitting fire from the native growth to any structure. 2. Maintain additional fire protection or firebreak by removing brush, flammable vegetation and combustible growth located from 30 feet to 100 feet (9144 mm to mm) from such buildings or structures, when required by the Fire Chief because of extra-hazardous conditions causing a firebreak of only 30 feet (9144 mm) to be insufficient to provide reasonable fire safety; Exception: Grass and other vegetation located more than 30 feet (9144 mm) from buildings or structures and less than 18 inches (457 mm) in height above the ground need not be removed where necessary to stabilize the soil and prevent erosion. H103 Corrective actions: 22
24 The Fire Chief is authorized to give notice to the owner of the property upon which conditions regulated by Section 102 exist to correct such conditions and if not corrected abate such conditions in accordance with the provisions of Chapter 8 of the Casa Grande City Code. 23
25 City of Casa Grande Amendments to International Residential Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
26 CHAPTER 1 ADMINISTRATION 2
27 CHAPTER 2 DEFINITIONS The following definition is amended as follows: R202 DEFINITIONS EXTERIOR WALL. An above-grade wall enclosing conditioned space that defines the exterior boundaries of a building. Includes between floor spandrels, peripheral edges of floors, roof and basement knee walls, dormer walls, gable end walls, walls enclosing a mansard roof, and basement walls with an average below grade wall area that is less than 50 percent of the total opaque and non-opaque area of that enclosing side. 3
28 CHAPTER 3 BUILDING PLANNING The following table is amended as follows: TABLE R USE LIVE LOAD Attics with storage b,e Attics without storage beg 10 Sleeping rooms (No other changes to Table) g. For trussed systems, this load need not be considered as acting simultaneously with other live loads imposed upon the ceiling framing or its supporting structure. The following sections are amended as follows: R309.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inch (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire-rated doors. Doors providing opening protection shall be self-closing and self-latching. R310.1 Emergency escape and rescue required openings. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R Such openings shall open directly into a public street, public alley, yard or court. 4
29 R320.1 Subterranean termite control. In areas favorable to termite damage In this jurisdiction, which is designated by Table R301.2(6) as moderate to heavy probability of termite infestation, as established by Table R301.2(1), methods of protection shall be by chemical soil treatment, pressure preservatively treated wood in accordance with the AWPA standards listed in Section R319.1, naturally termite-resistant wood, or physical barriers (such as metal or plastic termite shields), or any combination of these methods. 5
30 CHAPTER 4 FOUNDATIONS CHAPTER 5 FLOORS CHAPTER 6 WALL CONSTRUCTION CHAPTER 7 WALL COVERING CHAPTER 8 ROOF-CEILING CONSTRUCTION CHAPTER 9 ROOF ASSEMBLIES 6
31 Table R is amended as follows: CHAPTER 10 CHIMNEYS AND FIREPLACES TABLE R SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS ITEM LETTER REQUIREMENTS SECTION Hearth slab thickness A 4 R Hearth extension B 8 fireplace opening < 6 sq. ft. R (each side of opening) 12 fireplace opening 6 sq. ft. Hearth extension C 16 fireplace opening< 6 sq. ft. R (front of opening) 20 fireplace opening 6 sq. ft. Hearth slab reinforcing D Reinforced to carry its own R Thickness of wall of firebox E weight and all imposed loads. 10 solid brick or 8 where a firebrick lining is used. Joints in firebrick ¼ max. Distance from top of opening to throat Smoke chamber wall G thickness unlined wall Chimney H Four No. 4 full-length bars for Vertical reinforcing b chimney up to 40 wide. Add two No. 4 bars for each additional 40 or fraction of width or each additional flue R F 8 R for lined walls 8 for unlined walls R R Horizontal reinforcing b J ¼-inch ties at every 18 and two R ties at each bend in vertical steel Bond beams K No specified requirement Fireplace lintel L Noncombustible material. R Chimney walls with flue lining M Solid masonry units or hollow masonry units grouted solid with R at least 4 inch nominal thickness. Walls with unlined flue N 8 solid masonry. R Distances between N See Section R R adjacent flues Effective flue area P See Section R R (based on area of fireplace opening) Clearances: Combustible material Mantel and trim Above roof R See Sections R and R See Section R at roofline and 2 at 10. R R R
32 Anchorage b Strap Number Embedment into chimney Fasten to Bolts Footing Thickness Width S T 3/16 x 1 Two 12 hooked around outer bar with 6 extension 4 joists Two ½ diameter. 12 min. 6 each side of fireplace wall. R R For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 Square foot = m 2. Note: This table provides a summary of major requirements for the construction of masonry chimneys and fireplaces. Letter references are to Figure R , which shows examples of typical construction. This table does not cover all requirements, nor does it cover all aspects of the indicated requirements. For the actual mandatory requirements of the code, see the indicated section of text. a. The letters refer to Figure R b. Not required in Seismic Design Category A, B or C. 8
33 CHAPTER 11 ENERGY EFFICIENCY CHAPTER 12 MECHANICAL ADMINISTRATION 9
34 CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS The following section is added as follows: M Liquefied Petroleum Appliances. LPG appliances shall not be installed in an attic, pit or other location that would cause a ponding or retention of gas. 10
35 CHAPTER 14 HEATING AND COOLING EQUIPMENT The following sections are amended as follows: M Foundations and supports. Supports and foundations for the outdoor unit of a heat pump mechanical systems shall be raised at least 3 inches (76 mm) above the ground to permit free drainage of defrost water finished grade, and shall conform to the manufacturer s installation instructions. M Auxiliary and secondary drain systems. In addition to the requirements of Section M1411.3, a secondary drain or auxiliary drain pan shall be required for each cooling or evaporator coil where damage to any building components will occur as a result of overflow from the equipment drain pan or stoppage in the condensate drain piping. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than one-eighth unit vertical in 12 units horizontal (1-percent slope). Drain piping shall be a minimum of 3/4 inch (19.1 mm) nominal pipe size. One of the following methods shall be used: (The remainder of the section to remain unchanged.) 11
36 CHAPTER 15 EXHAUST SYSTEMS CHAPTER 16 DUCT SYSTEMS CHAPTER 17 COMBUSTION AIR CHAPTER 18 CHIMNEYS AND VENTS CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT CHAPTER 20 BOILERS/WATER HEATERS 12
37 CHAPTER 21 HYDRONIC PIPING CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS CHAPTER 23 SOLAR SYSTEMS 13
38 CHAPTER 24 FUEL GAS The following subsection is added to G as follows: 5. Liquefied Petroleum Appliances. LGP appliances shall not be installed in an attic, pit or other location that would cause a ponding or retention of gas. The following section is amended as follows: G (404.9) Minimum burial depth. Underground piping systems shall be installed a minimum depth of 12 inches (305 mm) below grade, except as provided for in Section G for metal piping and 18 inches (457 mm) for plastic piping. 14
39 CHAPTER 25 PLUMBING ADMINISTRATION The following section is amended as follows: P Water-supply system testing. Upon completion of the water supply system or a section thereof, the system, or portion completed, shall be tested and proved tight under a water pressure not less than the working pressure of the system; or, for piping systems other than plastic, by an air test of not less than 50 psi (344kPa). This pressure shall be held for at least 15 minutes. The water utilized for tests shall be obtained from a potable water source. 15
40 CHAPTER 26 GENERAL PLUMBING REQUIREMENTS CHAPTER 27 PLUMBING FIXTURES 16
41 CHAPTER 28 WATER HEATERS The following section is amended as follows: P Requirements of discharge pipe. The outlet of a pressure relief valve, temperature relief valve or combination thereof, shall not be directly connected to the drainage system. The discharge from the relief valve shall be piped full size separately to the floor, to the outside of the building or to an indirect waste receptor located inside the building. In areas subject to freezing, the relief valve shall discharge through an air gap into an indirect waste receptor located within a heated space, or by other approved means. The discharge shall be installed in a manner that does not cause personal injury or property damage and this is readily observable by the building occupants. The discharge from a relief valve shall not be trapped. The diameter of the discharge piping shall not be less than the diameter of the relief valve outlet. The discharge pipe shall be installed so as to drain by gravity flow and shall terminate atmospherically not more than 6 inches (152 mm) above the floor not less than 6 inches (152mm) nor more than 24 inches (610 mm) above the floor or finish grade. The outlet end of the discharge pipe shall not be threaded or have a valve or tee installed. 17
42 CHAPTER 29 WATER SUPPLY AND DISTRIBUTION CHAPTER 30 SANITARY DRAINAGE 18
43 CHAPTER 31 VENTS The following section is amended as follows: P Roof Extension. All open vent pipes which extend through a roof shall be terminated at least 6 inches above the roof or 6 inches above the anticipated snow accumulation, whichever is greater, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. 19
44 CHAPTER 32 TRAPS CHAPTER 33 GENERAL REQUIREMENTS CHAPTER 34 ELECTRICAL DEFINITIONS 20
45 CHAPTER 35 SERVICES IRC Table E is amended to as follows: ( Minimum Grounding Electrode Conductor Size column to remain the same) CONDUCTOR TYPES AND SIZES-THHW, Allowable Ampacity THW, THWN, USE, XHHW Service or Feeder Rating (Parallel sets of 1/10 and larger conductors are permitted in either a (Amperes) single raceway or in separate raceways) Copper Aluminum and Copper-clad <30C (86F) > 30C (86F) (AWG) aluminum / / /0 3/ /0 4/ or two sets of 1/0 3/0 250 kcmil or two sets of 2/0 4/0 or two sets of 1/0 300 kcmil or two sets of 3/ kcmil or two sets of 2/0 350 kcmil or two sets of 3/0 350 kcmil or two sets of 3/0 500 or two sets of 250 kcmil kcmil or two sets of 300 kcmil 500 kcmil 750 kcmil
46 CHAPTER 36 BRANCH CIRCUIT AND FEEDER REQUIREMENTS CHAPTER 37 WIRING METHODS 22
47 CHAPTER 38 POWER AND LIGHTING DISTRIBUTION The following section is amended as follows: E Bar sink receptacles Sink, wash basin, tub, or shower receptacles. All 125- volt, single-phase, 15- and 20-ampere convenience receptacles that serve a countertop surface, and that are located within 6 feet (1829 mm) of the outside edge of a wet bar sink any sink, wash basin, tub, or shower shall have ground-fault circuit-interrupter protection for personnel. Receptacle outlets shall not be installed in a face-up position in the work surfaces or countertops. 23
48 CHAPTER 39 DEVICES AND LUMINAIRES CHAPTER 40 APPLIANCE INSTALLATION CHAPTER 41 SWIMMING POOLS CHAPTER 42 CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER- LIMITED CIRCUITS CHAPTER 43 REFERENCED STANDARDS 24
49 CHAPTER 44 MANUFACTURED HOUSING CHAPTER 44, Manufactured Housing, is added as follows: SECTION 4401 GENERAL Purpose. The purpose of this Chapter is to provide standards to safeguard life and limb, health, property and public welfare by regulating and controlling the design, construction and quality of materials for foundation systems and building service equipment connections for the installation of manufactured homes, mobile homes, singlefamily factory built buildings, park models, and their accessory structures, as well as to provide standards for alterations, additions and repairs to such structures Scope. The provisions of this Chapter shall be applicable only to manufactured units used as a single-family dwelling unit. Accessory buildings and structures shall be classified as to occupancy as set forth in the International Building Code Application. Manufactured units which are in existence at the time of adoption of this guideline may have their existing use or occupancy continued if such use or occupancy was legal at the time of the adoption of this guideline, provided such continued use is not dangerous to life, health and safety. Exception: Installation of smoke detectors, see Section 4409 (a) below Maintenance. All manufactured units and their building service equipment, existing and new, and all parts thereof shall be maintained in a safe and sanitary condition. All devices or safeguards which are required by applicable codes or by the Manufactured Home Standards as may be established by the City or as established by the Office of Manufactured Housing, Arizona Department of Fire, Building and Life Safety, shall be maintained in conformance with the code or standard under which it was installed. The owner or his designated agent shall be responsible for the maintenance of manufactured homes, accessory structures and their building service equipment. To determine compliance with this subsection, the Building Official may cause any manufactured home, accessory building or structure to be inspected or re-inspected Applicability of Other Codes. In addition to complying with all applicable Federal, State, County, and City code provisions, the following shall be specifically adhered to: Casa Grande Municipal Code Chapter 15.40, Flood Damage Prevention. Any unit or property located in a 100 year floodplain or floodway shall comply with said Chapter s requirements. 25
50 Casa Grande Municipal Code Title 17 Single-Family Residential (R-1) Zone. Specifications in regards to: Principally permitted uses, permitted accessory uses, conditionally permitted uses, and minimum lot area Casa Grande Municipal Code, Title 17 Mobile Home Residential (R-4) Zone. Specifications in regards to: Principally permitted uses, and minimum lot area Conditionally Permitted Uses. In the granting of a conditionally permitted use by the Planning and Zoning Commission the following conditions shall be adhered to, in addition to those imposed by the Commission: a. Running gear shall be removed. b. Towing assembly (tongue) shall be removed. c. The exterior perimeter of the unit shall be mounted upon a block stem wall foundation, in addition to any interior pier blocking that may be required. The stem wall foundation shall be constructed to the structural standards of Veteran s Administration regulations. Exception: Units recessed into the ground. d. The exterior elements (eaves, stairs, porches, appliances, heating and cooling units, etc.) of the unit shall be painted and maintained in good condition to compliment the surrounding area Appeals. Persons who are aggrieved by orders, decisions, or determinations by the Building Official in the enforcement of this Chapter may make an appeal to the City of Casa Grande s Board of Appeals. Upon review by the Board of Appeals, the applicant shall provide an affidavit that the following conditions exist and will be complied with: a. Applicant is the bona fide owner of the mobile home. b. For existing units, the unit has been continuously occupied for a period of not less than one year immediately preceding the application date. c. The applicant intends to occupy the unit for a period of not less than one year from the issuance date of the permit. d. Set forth the reasons, and a description of evidence of hardship that the applicant would suffer if the appeal is not granted. 26
51 SECTION 4402 DEFINITIONS Section 4402 Definitions. The following terms shall, for the purposes of this chapter and as used elsewhere in the code, have the following meaning: ACCESSORY STRUCTURE. Installation, assembly, connection or construction of any habitable room, storage room, patio, porch, garage, carport, awning, skirting, retaining wall, evaporative cooler, refrigeration air conditioning system, solar system or wood decking attached to a new or used manufactured unit. ACT. National Manufactured Home Construction and Safety Standards Act of 1974 and as amended by applicable Public Laws. BUILDING SERVICE EQUIPMENT. Refers to the plumbing, mechanical, electrical and elevator equipment including piping, wiring, fixtures and other accessories which provide sanitation, lighting, heating, ventilation, cooling, refrigeration, firefighting and transportation facilities essential for the habitable occupancy of the building or structure for its designated use and occupancy. CERTIFICATE OF REHABILITATION. A certificate wherein a mobile home, having demonstrated that it can meet set standards that significantly decrease the life-safety hazards of the unit, is permitted to be installed within the City boundaries. The Arizona Office of Manufactured Housing s rehabilitation standards are set as the standard for the City. FACTORY BUILT BUILDING, SINGLE-FAMILY. Residential building which is either wholly or in substantial part manufactured at an off-site location to be assembled on-site. This does not include a manufactured home or mobile home as defined in this section. HUD. Means the United States Department of Housing and Urban Development. INSIGNIA OF APPROVAL. Numbered or serialized label or seal issued by the Office of Administration of the Arizona Department of Building and Fire Safety as certification of compliance with the provisions of this Chapter. INSTALLATION: Includes one or all of the following: a. Connecting new or used mobile homes, manufactures homes, park models or factory-built buildings to on-site utility terminals or repairing these utility connections. b. Placing new or used mobile homes, manufactured homes, park models, accessory structures or factory-built building on foundation systems or repairing these foundation systems. 27
52 c. Providing ground anchoring for new or used mobile homes or manufactured homes or repairing the ground anchoring. MANUFACTURED HOME. Structure built on or after June 15, 1976 in accordance with the Act. MANUFACTURED HOME STANDARDS. Manufactured Home Construction and Safety Standards as promulgated by HUD. MANUFACTURED UNIT. A generic term used to describe a manufactured home, mobile home, park model, factory-built building for single-family use or accessory structures. MOBILE HOME. Structure built prior to June 15, 1976, on a permanent chassis, capable of being transported in one or more sections and designed to be used with or without a permanent foundation as a dwelling when connected to on-site utilities except factory-built buildings. PARK MODEL (PARK TRAILER). A unit built on a single chassis, mounted on wheels and designed to be connected to utilities necessary for operation of installed fixtures and appliances and has a gross trailer area of not less than three hundred twenty square feet and not more than four hundred square feet when it is set up, except that it does not include fifth wheel trailers. Units shall be constructed to American National Standards Institute A SECTION 4403 PERMITS Permits. The following permits shall be required for all homes falling within this Chapter General. Manufactured Homes, park models and Mobile Homes shall not be installed, reinstalled, or occupied without first obtaining an installation permit from the Building Official Installations. An installation permit shall be issued only to those units that qualify as: a. Mobile home bearing the insignia of approval and issued a Certificate of Compliance by the Arizona Office of Manufactured Housing. b. Manufactured home. c. Park Model. d. Factory built building used as a single-family dwelling unit. e. Mobile home issued a Certificate of Rehabilitation by the City of Casa Grande. See Section 4409 (B) Accessory Structures. Permits shall be required for the installation, alteration, or repair of accessory structures and their building service equipment. 28
53 Additions, alterations and Repairs. A permit shall be obtained to add, alter, or repair a manufactured unit or park model and their building service equipment Application for Permit. To obtain a permit, the applicant shall file an application in writing on a form furnished by the Building Official. Every application shall state: a. The unit s manufacturer, serial number, model, year, and size. b. Be accompanied by a site plan showing all boundary lines, the location of the proposed unit, all structures, and utility locations. c. When deemed necessary by the Building Official provide additional plans, engineering calculations and other data Permit Issuance. If the Building Official finds that the work described in the submitted documents conform to the requirements of the Chapter and other pertinent codes, laws and ordinances, and that the fees specified have been paid, he shall issue a permit to the applicant Utility Service. Utility service shall not be provided to any building service equipment until approved by the Building Official Fees SECTION 4404 FEES a. Installation Permit. Fees shall be assessed per the Arizona Office of Manufactured Housing s Rules and Regulations. b. Accessory Structures. No fee shall be assessed to those accessory structures included in the installation permit, as permitted by the State Office of Manufactured Housing rules and regulations. Structures not part of the installation permit shall have their fees assessed as stated in the City of Casa Grande Consolidated Fee Schedule. c. Additions, Alterations, and Repairs. Fees shall be assessed as stated in the City of Casa Grande Consolidated Fee Schedule. d. Park Model. Same as Manufactured Home. Additional inspections will be assessed an additional fee as described in the City of Casa Grande Consolidated Fee Schedule. e. Rehabilitation Compliance Permit. Fees shall be assessed per the State Office of Manufactured Housing Rules and Regulations. 29
54 SECTION 4405 INSPECTIONS Installation. Shall consist of two inspections; a Set-up and a final Inspection Set-up Inspection. Consist of any one or combination of the following: a. Foundation inspection, concrete slab or under floor inspection, pier blocking inspection. b. Utility inspection. Inspection of any and all utilities services such as: water, sewer, gas, and electric Final Inspection. a. Utility inspection. Inspection of any and all utilities services not previously approved or inspected. b. Stair/ramp Inspection. See Section c. Accessory Structure(s) Inspection. When included as part of the installation contract, an accessory structure inspection is to be performed Accessory Structures. Inspections shall be as prescribed in Section 109 of this Code Additions, Alterations, and Repairs. Inspections shall be as prescribed in Section 109 of this Code Park Models. Upon issuance of a permit three inspections will be allotted. Additional inspections will be assessed an additional fee Rehabilitation Compliance Permit. Upon issuance of permit one inspection will be allotted. Additional inspections will be assessed an additional fee Location on Property. SECTION 4406 INSTALLATION AND CONSTRUCTION a. Permitted Locations. Units shall be installed as permitted by the applicable provisions from Title 17, Zoning, of the Casa Grande Municipal Code. b. Minimum Setbacks. Minimum setbacks from property lines or assumed property lines between units shall be as permitted by the applicable provisions from Title 17, Zoning, of the Casa Grande Municipal Code. 30
55 c. Encroachment: Permitted encroachment into required setbacks shall be as authorized by City of Casa Grande Municipal Code Exterior Wall and Opening Protection. Exterior wall and opening protection shall be measured from the property line or assumed property lines as follows: a. Fire Resistance of Exterior Walls: 1 hour less than 3 feet. b. Openings in Exterior Walls: Not Permitted less than 3 feet Height. Maximum building height Foundation Systems. Installation of foundation and unit support systems shall comply with the Arizona Office of Manufactured Housing s Rules and Regulations Anchoring Systems. Anchorage of units is recommended. When anchoring is provided is shall comply with the Arizona Office of Manufactured Housing s Rules and Regulations Skirting. Skirting shall be provided around the entire perimeter of the unit and shall comply with the Arizona Office of Manufactured Housing s Rules and Regulations. Exception: Units that have a masonry stem wall Additions, Alterations, and Repairs. Work may be performed to any manufactured unit without requiring the existing manufactured unit to comply with all requirements of this Chapter, provided the addition, alteration or repair conforms to that required for new construction, and provided that no hazard to life, health or safety will be created by such work. a. Additions shall be structurally separated from the manufactured unit. Exception: Submission of structural calculations to justify the omission of such separation. b. Additions and alterations made to a manufactured unit shall conform to one of the following: 1. Be designed and constructed to conform with the applicable provisions of the National Manufactured Home Construction and Safety Standards Act of 1974 (42 U.S.C. Section 5401, et seq.). A certificate of compliance issued by the manufacturer shall be provided for such structure. 2. Be designed and constructed in conformance with City codes. 31
56 SECTION 4407 STAIRS AND RAMPS Stairs and Ramps. Exterior stairs and ramps shall comply with the International Building Code Building Service Equipment. SECTION 4408 BUILDING SERVICE EQUIPMENT (a) Existing Equipment. Building service equipment lawfully in existence at the time of the adoption of the applicable codes may have their use, maintenance or repair continued if the use, maintenance or repair is in accordance with the original design and no hazard to life, health or property has been created by such building service equipment. (b) Additions, Alterations, and Repairs. Work may be performed to the building service equipment without requiring the existing building service equipment to comply with all requirements of this Chapter, provided the addition, alteration or repair conforms to that required for new construction, and provided that no hazard to life, health or safety will be created by such additions, alterations or repairs Special Provisions SECTION 4409 SPECIAL PROVISIONS (a) Smoke Detectors. Detectors shall be installed in all existing manufactured units. They may be battery operated or connected directly to an existing circuit. Detectors shall be installed as prescribed in this Section. (b) Certificate of Rehabilitation. Owners of mobile homes shall meet the City s Mobile Home Rehabilitation Standards set forth below, and comply with all other state laws, rules or regulations to obtain a Certificate of Rehabilitation. No mobile home may be moved within or brought into the City unless it has been completely rehabilitated by the owner. All rehabilitation work shall be done at the unit s present site. Upon completion of all rehabilitation work the owner may submit for a Rehabilitation Compliance Permit. Upon issuance of a Rehabilitation Compliance Permit the owner may move the mobile home to its approved site. Within five days of moving the unit to its approved site the owner shall call for a rehabilitation inspection. Upon successfully meeting all rehabilitation standards a Certificate of Rehabilitation and Installation Permit will be issued. (c) Mobile Home Rehabilitation Standards. 1. Gas Appliance Compartments. The walls, ceilings and doors of each compartment containing a gas fired furnace or water heater shall be lined with 5/16 inch gypsum board, unless the door opens to the exterior of the mobile home in which case the 32
57 door may be all metal construction. All exterior compartments must seal to the interior of the mobile home. 2. Emergency Escape. Each room designated expressly for sleeping purposes, shall have an exterior exit door or at least one outside egress window or other approved exit device with: A. A minimum clear height and width dimension of 22 inches. B. A minimum clear opening of five square feet. C. The bottom of the exit shall not be more than 44 inches above the floor. 3. Electrical Systems. All electrical systems shall: A. Have a smoke detector installed, as follows: The detector may be a single station alarm device. Shall be installed on any wall in a hallway or space communicating with each bedroom area and the living area on the living area side. When located in a hallway the detector shall be between the return air intake and the living area. Shall be installed in accordance with its listing. The top of the detector shall be located on a wall 4 inches to 12 inches below the ceiling. May be battery powered or may be connected to an electrical outlet box by a permanent wiring method into a general electrical branch circuit, without any switch between the overcurrent protection device protecting the branch circuit and the detector. B. Tested for continuity to assure metallic parts are properly bonded. C. Tested for operation to demonstrate that all equipment is in working order. D. Given a polarity check to determine proper connections. E. Protected for the required amperage load. F. If the unit wiring is of aluminum conductors, all receptacles and switches rated 20 amperes or less directly connected to the aluminum conductors shall be marked CO/ALR. G. All 125-volt, single phase 15- or 20-ampere receptacles installed in bathrooms or within 6 feet of a kitchen sink above a counter top surface shall have ground-fault circuit-interrupter protection for personnel. H. Exterior receptacle other than heat tape receptacles, shall be of the round fault circuit interrupter type. I. Conductors of dissimilar metals (Copper/Aluminum/ or Copper Clad Aluminum) must be connected in accordance with NEC Gas Piping System. The unit s gas piping system shall be tested as follows: 33
58 A. Pressure shall be measured with a mercury manometer or a gauge calibrated so as to read in increments of not greater than 1/10 pound or equivalent device. B. The source of normal operating pressure shall be isolated before the pressure test is made. C. Gas piping shall be tested with the appliance flex piping disconnected from the appliance and capped. The piping system shall withstand a pressure of at least 6-inch mercury or 3 PSO gauge for a period of not less than 10 minutes without showing any drop in pressure. D. After the appliance connections are reinstalled, the piping system and connections shall be tested with line pressure of not less than 10 inches or more than 14 inches water column air pressure. The appliance connections shall be tested for leakage with soapy water or bubble solution. 5. Gas Appliance Venting. All gas furnaces and water heater shall be vented to the exterior in accordance with the International Mechanical Code and the International Plumbing Code. 34
59 APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS The following section is amended as follows: AG105.2 Outdoor swimming pool. 1. The top of the barrier shall be at least inches. (No other changes to section) 35
60 City of Casa Grande Amendments to International Building Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
61 CHAPTER 1 ADMINISTRATION The following sections are amended as follows: SECTION Property Maintenance. The provisions of the International Property Maintenance Code shall apply, if and to the extent that it is adopted by the City of Casa Grande, to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants; and occupancy of existing premises and structures. SECTION Energy is hereby deleted in its entirety. SECTION Existing Structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the International Property Maintenance Code, if and to the extent that it is adopted by the City of Casa Grande, or the International Fire Code, or as is deemed necessary by the building official for the general safety and welfare of the occupants and the public. SECTION Deputies. In accordance with the prescribed procedures of this jurisdiction and with the concurrence of the appointing authority, the building official shall have the authority to appoint a deputy building official, the relatd technical officers, inspectors, plan examiners and other employees. Such employes shall have powers as delegated by the building official. For the maintenance of existing properties, see the International Property Maintenance Code, if and to the extent that it is adopted by the City of Casa Grande. 2
62 CHAPTER 2 DEFINITIONS 3
63 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION The following sections are amended as follows: SECTION Group I-1. This occupancy shall include buildings, structures or parts thereof housing more than persons, on a 24-hour basis, who because of age, mental disability or other reason, live in a supervised residential environment that provides supervisory care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This group shall include, but not limited to, the following: Residential board and care facilities Assisted living centers Halfway houses Group homes Congregate care facilities Social rehabilitation facilities Alcohol and drug abuse centers Convalescent facilities A facility such as the above with five or fewer person shall be classified as a Group R-3, a facility such as the above with more than 5 persons shall be classified as an R-4 Condition 1, or shall comply with the International Residential Code in accordance with Section where the building is in compliance with Section 419 of this code. SECTION Group I-2. This occupancy shall include building and structures used for medical, surgical, psychiatric, nursing, custodial, personal, or directed care on a 24- hour basis of more than five persons who are not capable of self-preservation by responding to an emergency situation without physical assistance from staff. This group shall include, but not be limited to, the following: Hospitals Nursing homes (both intermediate-care facilities and skilled nursing facilities) Mental hospitals Detoxification facilities A facility such as the above with five or fewer persons shall be classified as Group R-3 or shall comply with the International Residential Code in accordance with Section This occupancy shall also include building and structures used for assisted living homes providing supervisory, personal, or directed care on a 24-hour basis of more than 10 4
64 persons who are not capable of self-preservation by responding to an emergency situation without physical assistance from staff. A facility such as the above with ten or fewer persons shall be classified as R-4 Condition 2. SECTION Group R-4. Residential occupancies shall include buildings arranged for occupancy as residential care/assisted living homes including more than five but less than occupants, excluding staff Condition 1. This occupancy condition shall include facilities licensed to provide supervisory care services in which occupants are capable of self preservation by responding to an emergency situation without physical assistance from staff. Condition 1 facilities housing more than 10 persons shall be classified as a Group I Condition 2. This occupancy condition shall include facilities licensed to provide personal or directed care services in which occupants are incapable of self preservation by responding to an emergency without physical assistance from staff. Condition 2 facilities housing more than 10 persons shall be classified as Group I-2. R-4 occupancies shall meet the requirements for construction as defined in Group R-3 except as otherwise provided for in this code or in Section 419 or shall comply with the International Residential Code in accordance with section where the building is in compliance with Section 419 of this code. SECTION Definitions DIRECTED CARE SERVICE. Care of residents, including personal care services, who are incapable of recognizing danger, summoning assistance, expressing need, or making basic care decisions. PERSONAL CARE SERVICE. The care of residents who do not require chronic or convalescent medical or nursing care. Personal care involves responsibility for the safety of the resident while inside the building. Assistance with activities of daily living that can be performed by persons without professional skills or professional training and includes the coordination or provision of intermittent nursing services ant the administration of medications and treatments. RESIDENTIAL CARE/ASSISTED LIVING HOME. A building or part thereof housing a maximum of 10 persons, excluding staff, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides personal care supervisory, personal, or directed services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This classification shall include, but not be limited to, the following: residential board and care facilities, assisted living homes, halfway houses, group homes, congregate care facilities, social rehabilitation facilities, alcohol and drug abuse centers and convalescent facilities. 5
65 SUPERVISORY CARE SERVICE. General supervision, including daily awareness of resident functioning and continuing needs. 6
66 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY The following section is amended as follows: SECTION SEPARATION. 1. The private garage shall be separated from the dwelling unit and its attic area by means of a minimum ½-inch (12.7 mm) gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8-inch Type X gypsum board or equivalent. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors, or solid or honeycomb core steel doors not less than 1 3/8 inches (34.9 mm) thick, or doors in compliance with Section Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Doors shall be self-closing and self-latching. In buildings protected with an automatic fire sprinkler system, including the private garage, the room finish materials shall be permitted to be a minimum ½-inch (12.7 mm) gypsum board applied to the garage side. The following section is added: SECTION 419 Residential Care/Assisted Living Homes Applicability. The provisions of this section shall apply to a building or part thereof housing more than five but not more than 10 persons, excluding staff, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides licensed care services. Except as specifically required by this division, R-4 occupancies shall meet all applicable provisions of Group R General. Building or portions of buildings classified as R-4 occupancies shall meet all of the applicable provisions of Group R-3, may be constructed of any materials allowed by this code, shall not exceed two stories in height nor be located above the second story in any building, and shall not exceed 2000 square feet above the first story except as provided in Section Special Provisions. R-4 occupancies having more than 2000 square feet of floor area above the first floor shall be of not less than one-hour fire-resistive construction throughout Mixed Uses. R-4 occupancies shall be separated from other uses as provide in Table Access and Means of Egress Facilities. 7
67 Accessibility. R-4 occupancies shall be provided with at least one accessible route per the Arizonans with Disabilities Act. Sleeping rooms and associated toilets shall be accessible. Exception: Existing buildings shall comply with Section Bathing and toilet facilities need not be made accessible, but shall be provided with grab bars in accordance with ICC/ANSI A Exits Number of Exits. Every story and basement, or portion thereof, shall have not less than two exits. Exception: Basements and stories above the first floor containing no sleeping rooms may have one means of egress as provided in Chapter Distance to Exits. The maximum travel distance shall comply with Section 1004, except that the maximum travel distance from the center point of any sleeping room to an exit shall not exceed 75 feet Emergency Exit Illumination. In the event of a power failure, exit illumination shall be automatically provided from an emergency system powered by storage batteries or an onsite generator set installed in accordance with the ICC Electrical Code Emergency Escape and Rescue. R-4 occupancies shall comply with the requirements of Section 1025, except that Exception 1 to Section does not apply to R-4 occupancies Delayed egress locks. In R-4 Condition 2 occupancies, delayed egress locks shall be permitted in accordance with Sections and , items 1, 2, 4, 5 and Smoke Detectors and Sprinkler Systems Smoke Alarms. All habitable rooms and hallways in R-4 occupancies shall be provided with smoke alarms installed in accordance with Section Sprinkler Systems. R-4 occupancies shall be provided with a sprinkler system installed in accordance with Section as amended. Sprinkler systems installed under this Section shall be installed throughout, including attached garages, and in Condition 2 facilities shall include attics and concealed spaces of or containing combustible materials. Such systems may not contain unsupervised valves between the domestic water riser control valve and the sprinklers. In R-4 Condition 2 8
68 occupancies, such systems shall contain water-flow switches electrically supervised by an approved supervising station, and shall sound an audible signal at a constantly attended location. Exception: Existing R-4 occupancies as of March 30, 2008 shall not be required to install an automatic sprinkler system unless there is a upward change in the number of occupants the facility is licensed to care for Residential care/assisted living facilities. All new residential care and assisted living facilities having more than 5 persons and licensed by the Arizona Department of Health Services or the Arizona Department of Economic Security to provide nursing services, directed care services, supervisory care services and/or personal care services shall be provided with an automatic fire protection system complying with Section 903.3, as applicable, and shall utilize fast response or residential sprinkler heads appropriate for the specific occupancy. The fire sprinkler system activation and control valves shall be monitored by an approved central station service. Exceptions: 1. State licensed residential care/assisted living facilities in which all of the care recipients are capable of self-preservation and responding to an emergency situation without assistance from another person. 2. State licensed residential care/assisted living facilities in which some or all of the care recipients are incapable of self-preservation or of responding to an emergency situation without assistance from another person, and that legally existed prior to August 1,
69 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS The following sections are amended as follows: SECTION Sprinklered, one story. The area of a one-story, Group B, F, M or S building or a one-story Group A-4 building of other than Type V construction shall not be limited when the building is provided with an automatic sprinkler system throughout in accordance with Section , and is surrounded and adjoined by public ways or yards not less than 60 feet ( mm) in width. Exceptions: 1. (No change) 2. (No change) Such buildings may contain other occupancies, without H fire areas, provided that such occupancies do not occupy more than 10 percent of the area of any floor of a building, nor more than the tabular values permitted in the occupancy by Table 503 for such occupancy. Exception: Group H fire areas as permitted by Section SECTION Two story. The area of a two-story, Group B, F, M or S building shall not be limited when the building is provided with an automatic sprinkler system in accordance with Section throughout, and is surrounded and adjoined by public ways or yards not less than 60 feet ( mm) in width. Such buildings may contain other occupancies, without H fire areas, provided that such occupancies do not occupy more than 10 percent of the area of any floor of a building, nor more than the tabular values permitted in the occupancy by Table 503 for such occupancy. Exception: Group H fire areas as permitted by Section
70 CHAPTER 6 TYPES OF CONSTRUCTION CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION CHAPTER 8 INTERIOR FINISHES 11
71 CHAPTER 9 FIRE PROTECTION SYSTEMS The following sections of Chapter 9 of the International Building Code are deleted in their entirety and replaced with the sections of Chapter 9 of the 2003 International Fire Code (as amended by the City of Casa Grande Amendments to the 2003 International Fire Code set forth in the 2008 City of Casa Grande Amendments to the Building, Health, and Safety Code) as set forth below: SECTION 903 Automatic Sprinkler Systems SECTION 904 Act. Automatic Fire Extinguisher Systems SECTION 905 Standpipe Systems SECTION 906 Portable Fire Extinguishers SECTION 907 Fire Alarm and Detection Systems SECTION 908 Emergency Alarm Systems For purposes of this Chapter 9, the term building official shall mean both the building official as defined in this Code, and the fire code official as appointed pursuant to the International Fire Code. 12
72 CHAPTER 10 MEANS OF EGRESS The following sections are amended as follows: SECTION Door Swing. Egress doors shall be side-hinged swinging. Exceptions: 1. Private garages, office areas, factory and storage areas with an occupant load of 10 or less. 2. Group I-3 occupancies used as a place of detention. 3. Doors within or serving a single dwelling unit in Groups R-2, R-3, and R-4 as applicable in Section (no other changes) SECTION Panic and Fire Exit Hardware. Where panic and fire exit hardware is installed, it shall comply with the following: 1. The actuating portion of the releasing device shall extend at least one-half of the door leaf width. 2. A maximum unlatching force of 15 pounds (67 N). Each door in a means of egress from an occupancy of Group A, with the exception of a main exit in compliance with Section (2), or E having an occupant load of 100 or more and any occupancy of Group H-1, H-2, H-3 or H-5 shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware. If balanced doors are used and panic hardware is required, the panic hardware shall be of the push-pad type and the pad shall not extend more than one-half the width of the door measured from the latch side. SECTION Assembly other exits. In addition to having access to a main exit, each level of an occupancy in Group A having an occupant load of greater than 300 shall be provided with additional exits means of egress that shall provide an egress capacity for at least one-half of the total occupant load served by that level and comply with Section Exception is deleted in its entirety. 13
73 CHAPTER 11 ACCESSIBILITY Chapter 11 is amended as follows: CHAPTER 11 ARIZONANS WITH DISABILITIES ACT SECTION 1101 GENERAL Scope. Arizonans with Disabilities Act (Arizona Revised Statutes, Title 41, Chapter 9, Article 8), and the Arizonans with Disabilities Act Implementing Rules (Arizona Administrative Code, Title 10, Chapter 3, Article 4), which rules incorporate the federal Americans with Disabilities Act Accessibility Guidelines for Building and Facilities, is hereby adopted as the Arizonans with Disabilities Act of the City Of Casa Grande and shall apply to new construction and alterations and are not required in building or portions of existing buildings that do not meet the standards and specifications and this act is hereby referred to, adopted, and made a part hereof as though fully set forth in this section. 14
74 CHAPTER 12 INTERIOR ENVIRONMENT CHAPTER 13 ENERGY EFFICIENCY This Chapter is Deleted in its Entirety 15
75 CHAPTER 14 EXTERIOR WALLS Weather protection. Protection against condensation in the exterior wall assembly shall be provided in accordance with the International Energy Conservation Code. 16
76 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES The following section is amended as follows: SECTION Roof Drainage. Design and installation of roof drainage systems shall comply with this Section and the International Plumbing Code. SECTION Where Required. All roofs, paved areas, yards, courts and courtyards shall drain into a separate storm sewer system, or a combined sewer system, or to an approved place of disposal. SECTION Roof design. Roofs shall be designed for the maximum possible depth of water that will pond thereon as determined by the relative levels of roof deck and overflow weirs, scuppers, edges or serviceable drains in combination with the deflected structural elements. In determining the maximum possible depth of water, all primary roof drainage means shall be assumed to be blocked. SECTION Overflow drainage required. Overflow (emergency) roof drains or scuppers shall be provided where the roof perimeter construction extends above the roof in such a manner that water will be entrapped if the primary drains allow buildup for any reason. SECTION Separate systems required. Overflow roof drain systems shall have the end point of discharge separate from the primary stem. Discharge shall be above grade, in a location, which would normally be observed by the building occupants or maintenance personnel. SECTION Overflow drains and scuppers. Where roof drains are required, overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches (51 mm) above the low point of the roof, or overflow scuppers having three times the size of the roof drains may be installed in the adjacent parapet walls. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by the plumbing code. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when sizing the secondary roof drain system. 17
77 CHAPTER 16 STRUCTURAL DESIGN The following sections are amended as follows: TABLE Revise as follows: OCCUPANCY OR USE 27. Residential One- and two-family dwellings Uninhabitable attics with storage Habitable attics and sleeping areas (no other changes in item 27) UNIFORM (psf) CONCENTRATED (lbs.) 18
78 CHAPTER 17 STRUCTURAL TEST AND SPECIAL INSPECTIONS The following section is amended by adding the following exceptions: Section Masonry Construction Exception: 3. Masonry fences six feet or less in height above grade. 4. Masonry retaining walls four feet or less in height from bottom of footing to top of wall unless supporting a surcharge or impounding flammable liquids. 19
79 CHAPTER 18 SOILS AND FOUNDATIONS The following sections are amended as follows: Presumptive load-bearing values. The maximum allowable foundation pressure, lateral pressure or lateral sliding resistance values for supporting soils at or near the surface shall not exceed the values specified in Table unless data to substantiate the use of a higher value are submitted and approved. Presumptive load-bearing values shall apply to materials with similar physical characteristics and dispositions. Mud, organic silt, organic clays, peat or unprepared fill shall not be assumed to have a presumptive load bearing capacity unless data to substantiate the use of such a value are submitted. EXCEPTION: A presumptive load-bearing capacity is permitted to be used where the building official deems the load-bearing capacity of mud, organic silt or unprepared fill is adequate for the support of lightweight and temporary structures. 20
80 CHAPTER 19 CONCRETE CHAPTER 20 ALUMINUM CHAPTER 21 MASONRY CHAPTER 22 STEEL CHAPTER 23 WOOD CHAPTER 24 GLASS AND GLAZING 21
81 CHAPTER 25 GYPSUM BOARD AND PLASTER CHAPTER 26 PLASTIC CHAPTER 27 ELECTRICAL CHAPTER 28 MECHANICAL SYSTEMS 22
82 CHAPTER 29 PLUMBING SYSTEMS The following table is amended as follows: Revision to: TABLE Minimum Number of Required Plumbing Facilities (a) No. CLASSIFICATION USE GROUP DESCRIPTION WATER CLOSETS (SEE SECTION OF THE INTERNATIONAL PLUMBING CODE FOR URINALS) LAVATORIES MALE FEMALE MALE FEMALE BATH TUBS OR SHOWERS DRINKING FOUNTAINS (SEE SECTION OF THE INTERNATIONAL PLUMBING CODE OTHER 2 Business (see Sections , , , and ) B Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial and similar uses 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 1 per 40 for the first 50 and 1 per 80 for the remainder exceeding 50 1 per service sink 6 Mercantile (see Section , and ) M Retail stores, service stations, shops, salesrooms, markets and shopping centers 1 per per per 1,000 1 service sink (Remainder of table has no amendments) 23
83 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS CHAPTER 31 SPECIAL CONSTRUCTION Section 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICE is deleted in its entirety. CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT AWAY CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION 24
84 CHAPTER 34 EXISTING STRUCTURES The following section is amended as follows: SECTION Compliance with other codes. Alterations, repairs, additions and changes of occupancy to existing structures shall comply with the provision for alterations, repairs, additions and changes of occupancy in the International Fire Code, International Fuel Gas Code, International Plumbing Code, International Property Maintenance Code, if and to the extent it is adopted, International Private Sewage Disposal Code, International Mechanical Code, International Residential Code and ICC Electrical Code. 25
85 CHAPTER 35 REFERENCED STANDARDS 26
86 CHAPTER 36 REGISTERED INDUSTRIAL PLANT Chapter 36, Registered Industrial Plant, is added to read as follows: Scope. Registered Industrial Plants are exempt from the requirements Section 105 ( Permits ) of this Code, for work on existing building, structures and utilities accessory thereto that do not increase the floor area, height, or occupancy. These provisions are limited to buildings owned or leased by the plant and under direct control of the holder of the registration. Use of these provisions shall not be construed to waive any requirements of this Code, and all applicable requirements shall be complied with. The plant registration is not transferable Definition. For the purpose of this Code, a Registered Industrial Plant is a person, firm, corporation, or political entity engaged in manufacturing, processing, or service which requires specialized buildings, utilities and equipment to the extent that the plant maintains full-time personnel for the operation and maintenance of such buildings, utilities and equipment and when such plant has complied with all the provisions of this Chapter Qualifications. (a) A Registered Industrial Plant shall have in its employ an engineer registered in the State of Arizona who shall be responsible for complying with the provisions of this Code. (b) Buildings or structures qualify as a Registered Industrial Plant after a Certificate of Occupancy has been issued for the structure Application. To obtain Registration, the applicant shall file an application on a form furnished by the Building Official. Appropriate action shall be taken by the Building Official on such application and the applicant shall be notified within ten days of submittal. If the application is disapproved, the applicant may appeal from such decision to the City Board of Appeals. No filing fee will be required to appear before the Board Registration Fees and Renewal. Every applicant for registration shall pay a fee at the time of approval as set forth in the City of Casa Grande s Consolidated Fee Schedule. The registration fee may be prorated by one-twelfth (1/12) of the full amount, for each month that has fully elapsed at the date of application submittal. In no case however shall the registration fee be prorated to less than $ Registrations shall expire on December 31 st of each year and may be renewed voluntarily each year by payment of the fee before December 31. Any work performed after expiration without permits and inspections as required by this Chapter shall be a violation of this Code. 27
87 Work Report and Inspections. A report of work done under the plant registration shall be signed and sealed by the registered engineer and submitted monthly to the Building Official together with any plans and valuation of work to buildings or utilities covered by the Code. When no work is done, no report is required to be submitted. Exception: Repair of electrical, plumbing, or mechanical systems directly related to production or testing. Plans submitted pursuant to this Section may be reviewed and inspection of the work conducted by the Building Official or authorized representatives as set forth in this Code; provided, however, that work may proceed without inspection pursuant to this Section. The engineer may request a plan review or inspection of any work performed under this Section without payment of additional fees Validity of Registration. Registration shall be valid only as long as the named engineer remains in the employ of the plant. If the engineer should leave the employ of the plant, registration is suspended until another registered engineer is assigned the responsibility for work done under the registration. The registrant shall notify the Building Official immediately and shall call for inspection of any work in progress. Before any new work commences while registration is invalid or suspended, permits and inspections shall be obtained pursuant to City Code Revocation of Registration. The Building Official may suspend or revoke a registration when the engineer or plant fails to comply with any of the registration responsibilities or provisions of this Code. When the Building Official deems that registration shall be suspended or revoked, the procedure shall be as follows: a. The plant shall be notified in writing by certified mail at least seven days prior to suspension or revocation. b. Upon receipt of the notice, the plant may request a hearing. Such request shall be in writing to the Building Official within seven days of receipt of notice. i. If a hearing is requested by the plant, the Building Official shall set a time, date, and place and so notify the plant. ii. When a hearing is conducted, the plant and other interested parties may be in attendance. Upon completion of the hearing, the Building Official shall take all evidence submitted under advisement and shall notify the plant of this findings in writing by certified mail. 28
88 iii. If the decision rendered by the Building Official is adverse to the registrant, the plant may appeal from such decision within ten days to the City Board of Appeals. 29
89 City of Casa Grande Amendments to International Fuel Gas Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
90 CHAPTER 1 ADMINISTRATION Section Fee Refunds is hereby amended by inserting 80 in subsections 2 and 3 as the maximum percentage of fee allowed to be refunded. Section Stop Work Orders is hereby amended by inserting $250 as the minimum fine and $2500 as the maximum fine. 2
91 3
92 City of Casa Grande Amendments to International Mechanical Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
93 CHAPTER 1 ADMINISTRATION Section Fee Refunds is hereby amended by inserting 80 in subsections 2 and 3 as the maximum percentage of fee allowed to be refunded. Section Stop Work Orders is hereby amended by inserting $250 as the minimum fine and $2500 as the maximum fine. 2
94 3
95 City of Casa Grande Amendments to International Plumbing Code, 2003 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd.
96 Casa Grande, AZ CHAPTER 1 ADMINISTRATION Section Fee Refunds is hereby amended by inserting 80 in subsections 2 and 3 as the maximum percentage of fee allowed to be refunded. Section Stop Work Orders is hereby amended by inserting $250 as the minimum fine and $2500 as the maximum fine. 2
97 CHAPTER 2 DEFINITIONS 3
98 CHAPTER 3 GENERAL REGULATIONS The following section is amended as follows: Water-supply system test. Upon completion of a section of or the entire water supply system, the system, or portion completed, shall be tested and proved tight under a water pressure not less than the working pressure of the system; or, for piping systems other than plastic, by an air test of not less than 50 psi (344kPa). This pressure shall be held for at least 15 minutes. The water utilized for tests shall be obtained from a potable source of supply. The required tests shall be performed in accordance with this section and Section
99 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS 5
100 CHAPTER 5 WATER HEATERS The following section is amended as follows: Discharge. The relief valve shall discharge full size to a safe place of disposal such as the floor, outside the building, or an indirect waste receptor. The discharge pipe shall not have any trapped sections and shall have a visible air gap or air gap fitting located in the same room as the water heater. The outlet end of the discharge pipe shall not be threaded and such discharge pipe shall not have a valve or tee installed. Relief valve piping shall be piped independent of other equipment drains or relief valve discharge piping to the disposal point. Such pipe shall be installed in a manner that does not cause personal injury to occupants in the immediate area or structural damage to the building constructed so as to discharge in a downward direction, and shall terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the finish surface or grade. 6
101 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION CHAPTER 7 SANITARY DRAINAGE CHAPTER 8 INDIRECT/SPECIAL WASTE CHAPTER 9 VENTS CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS CHAPTER 11 STORM DRAINAGE 7
102 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS CHAPTER 13 REFERENCED STANDARDS 8
103 City of Casa Grande Amendments to National Electrical Code, 2005 Edition Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande Resolution # Effective: (Date) By: City Of Casa Grande 510 E. Florence Blvd. Casa Grande, AZ 85222
104 CHAPTER 1 GENERAL 2
105 CHAPTER 2 WIRING AND PROTECTION The following article is amended as follows: Ground-Fault Circuit-Interrupter Protection for Personnel FPN: See Section for ground-fault circuit-interrupter protection for personnel on feeders. (No changes to Article with the exception of the following revisions): (A) Dwelling Units. All 125-volt, single-phase, 15-and 20-ampere receptacles installed in the locations specified in: (1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (7) Laundry, utility, and wet bar sinks. Where the receptacles are installed within 1.8 m (6 ft) of the outside edge of the wet bar sink. Convenience receptacles located within 1.8 m (6ft) of any sink, wash basin, tub, or shower. (B) Other than Dwelling Units. All 125-volt, single-phase, 15-and 20-ampere receptacles installed in the locations specified in (1) through (5 6) shall have groundfault circuit-interrupter protection for personnel. (6) Convenience receptacles located within 1.8 m (6 ft) of sink, wash basin, tub, or shower. The following article is added as follows: Location. All service rated 1000 or more located inside a building shall be enclosed within a room or space separated from the rest of the building by not less that one-fire-resistive occupancy separation from the rest of the building by not less than one-hour fire- resistive occupancy separation or fire barrier installed in compliance with the building code. The following article is amended as follows: Types of Equipment Grounding Conductors The equipment grounding conductor run with or enclosing the circuit conductors shall be one or more or a combination of the following: 1. A copper, aluminum, or copper-clad aluminum conductor. This conductor shall be solid or stranded; insulated, covered, or bare; and in the form of a wire or a busbar any shape. 2. Threaded Rigid metal conduit and fittings. 3. Threaded Intermediate metal conduit and fittings. 3
106 4. Electrical metallic tubing. 5. Listed flexible metal conduit that is not listed for grounding and meeting all the following conditions. a. The conduit is terminated in fittings listed for grounding. b. The circuit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less. c. The combined length of flexible metal conduit and flexible metallic tubing and liquidtight flexible metal conduit in the same ground return path does not exceed 6 ft (1.83 m). d. The conduit is not installed for flexibility. 6. Listed liquidtight flexible metal conduit meeting all the following conditions. a. The conduit is terminated in fitting listed for grounding. b. For trade sizes 3/8 in. through ½ in., the circuit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less. c. For trade sizes 3/8 in. through 1 ¼ in., the circuit conductors contained in the conduit are protected by over current devices rated not more than 60 amperes and there is no flexible metal conduit, flexible metallic tubing, or liquidtight flexible metal conduit in trade sizes 3/8 in. or ½ in., in the grounding path.. d. The combined length of flexible metal conduit and flexible metallic tubing and liquidtight flexible metal conduit in the same ground return path does not exceed 6 ft (1.83m). e. The conduit is not installed for flexibility. 7. Flexible metallic tubing where the tubing is terminated in fittings listed for grounding and meeting all the following conditions. a. The circuit conductors contained in the tubing are protected by overcurrent devices rated at 20 amperes or less. b. The combined length of flexible metal conduit and flexible metallic tubing and liquidtight flexible metal conduit in the same ground return path does not exceed 6 ft (1.83 m) Armor of Type AC cable as provided in Section The copper sheath of mineral-insulated, metal-sheathed cable Type MC cable where listed and identified for grounding in accordance with the following: a. The combined metallic sheath and grounding conductor or interlocked metal tape-type MC cable. b. The metallic sheath or the combined metallic sheath and grounding conductors of the smooth corrugated tube type MC cable. The metallic sheath or the combined metallic sheath and grounding conductors of type MC cable with an individual equipment grounding conductor Cable trays as permitted in Sections 392.3(C) and Cablebus framework as permitted in Section Other listed electrically continuous metal raceways and listed auxiliary gutters for grounding. 14. Surface metal raceways listed for grounding. 4
107 CHAPTER 3 WIRING METHODS AND MATERIALS The following articles and table are amended as follows: (B)(6) 120/240-Volt and 120/208-Volt, 3-Wire, Single-Phase Dwelling Services and Feeders. For dwelling units, conductors, as listed in Table (B)(6) shall be permitted as 120/240-volt and 120/208 volt, 3-wire, phase-serviceentrance conductors, service lateral conductors, and feeder conductors that serve as the main power feeder to a dwelling unit and are installed in raceway or cable with or without equipment grounding shall not be required to be larger than their serviceentrance conductors. The grounded conductor shall be permitted to be smaller than the ungrounded conductors, provided the requirements of Sections 215.2, , and are met. Table (B)(6). Conductor Types and Sizes for 120/240-Volt and 120/208- Volt, 3-Wire, Single-Phase Dwelling Services and Feeders. Conductor Types RHH, RHW, RHW-2, THHN, THHW, THW, THW-2, THWN, THWN-2, XHHW, XHHW-2, SE, USE, USE-2 Conductor (AWG or kcmil) Copper Aluminum or Service or Feeder Service or Feeder Rating (Amperes) Copper-Clad Aluminum Rating (Ampere) <30 C (86 F) >30 C (86 F) 5
108 Uses Permitted. Type NM, Type NMC, and Type NMS cables shall be permitted to be used in the following: (1) One- and two-family dwellings and other residential accessory structures. (2) Multifamily dwellings permitted to by Types III, IV, And V construction except as prohibited in 334. (3) Other structures permitted to be of Types II, IV, and V construction except as prohibited in Cables shall be concealed within walls, floors, or ceilings that provide a thermal barrier of material that has at least a 15-minute finish rating as identified in listings of fire-rated assemblies. FPN No. 1: Types of building construction and occupancy classifications are defined in NFPA , Standard on Types of Building Construction, or the applicable building code, or both. FPN No. 2: See Annex E for determination of building types [NFPA 220, Table 3-1] (4) Cable trays in structures permitted to be Types III, IV, or V where the cables are identified for the use. FPN: See for temperature limitation of conductors Uses Not Permitted. EMT shall not be used under the following conditions: (Items 1 through 6 to remain the same) (7) On or below grade. 6
109 CHAPTER 4 EQUIPMENT FOR GENERAL USE 7
110 CHAPTER 5 SPECIAL OCCUPANCIES The following articles are amended as follows: (B) Types of Equipment Grounding Conductors. (Article remains the same, delete exception): Exception: In class I, Division 2 locations, the bonding jumper shall be permitted to be deleted where all the following conditions are met (a) Listed liquidtight flexible metal conduit 1.8 m (6 ft) or less in length, with fittings listed for grounding, is used. (b) Over current protection in the circuit is limited to 10amperes or less. (c) The load is not a power utilization load (B) Types of Equipment Grounding Conductors. (Article remains the same, delete exception): Exception: In class II, Division 2 locations, the bonding jumper shall be permitted to be deleted where all the following conditions are met (a) Listed liquidtight flexible metal conduit 1.8 m (6 ft) or less in length, with fittings listed for grounding, is used. (b) Over current protection in the circuit is limited to 10amperes or less. (c) The load is not a power utilization load (B) Types of Equipment Grounding Conductors. (Article remains the same, delete exception): Exception: In class III, Division 1 and 2 locations, the bonding jumper shall be permitted to be deleted where all the following conditions are met (a) Listed liquidtight flexible metal conduit 1.8 m (6 ft) or less in length, with fittings listed for grounding, is used. (b) Over current protection in the circuit is limited to 10 amperes or less. (c) The load is not a power utilization load. 8
111 CHAPTER 6 SPECIAL EQUIPMENT CHAPTER 7 SPECIAL CONDITIONS CHAPTER 8 SERVICE UTILITIES CHAPTER 9 TABLES 9
City of Casa Grande. 2014 Amendments to the City of Casa Grande Building, Health, and Safety Codes, 2012 Editions
City of Casa Grande 2014 Amendments to the City of Casa Grande Building, Health, and Safety Codes, 2012 Editions Designated as a Public Record In: Casa Grande City Clerk s Office Pursuant to Casa Grande
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have
Building Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
How To Protect A Swimming Pool
County of Gloucester Codes Compliance Building Department Building Three P. O. Box 329 Gloucester, Virginia 23061 Building Code Guidelines Residential Swimming Pools & Spas KEEP YOUR POOL SAFE CODE REQUIREMENTS
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
Chapter 5. Code Enforcement
Chapter 5 Code Enforcement Part 1 Uniform Construction Code 5-101. Purpose 5-102. Election to Administer and Enforce Construction Code Act 5-103. Adoption of Uniform Construction Code 5-104. Amendments
Automatic Fire Sprinkler Submittal Requirements
Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
The City of Basehor, Kansas
The City of Basehor, Kansas Residential and Miscellaneous Permits This list provides general information regarding permit requirements for various residential construction and maintenance activities. The
Overview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
CHIMNEYS AND FIREPLACES
CHAPTER 10 CHIMNEYS AND FIREPLACES > > Pursuant to ORS 215.730, if a single-family dwelling located on forest-zoned lands has a chimney or chimneys, each chimney shall have a spark arrester. SECTION R1001
LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado 80027 303-666-8809
LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado 80027 303-666-8809 Contractor s Checklist and Installation Guide TABLE OF CONTENTS Fire Protection Narrative........... 3 Fire
Winnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers
City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.
ADMINISTRATIVE CODE CHAPTER 1
CHAPTER 1 ADMINISTRATIVE CODE SECTION 101 TITLE AND SCOPE 101.1 Title. This document is The North Carolina Administrative Code and Policies, hereinafter known as this code. Any references to International
#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist
#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist Case #: Date: Project Name: Site Address: Application Submittal Building permit applications and plans can be submitted to the
Amendments to the 2012 INTERNATIONAL FIRE CODE
Amendments to the 2012 INTERNATIONAL FIRE CODE 2012 Edition, International Fire Code. Section 101.1 Amend to read as follows. 101.1 Title. These regulations shall be known as the Fire Code of the City
How To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
SECTION 105 PERMITS. 2. Fences not over 6 feet (1829 mm) high. 3. Oil derricks.
SECTION 105 PERMITS 105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install,
PLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet
Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet 1. Definitions a. AHJ Authority Having Jurisdiction. The Fire Chief or Fire Marshal of a given Fire District
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions
Building Permit, Fire Inspection and Operating Permit Fee Schedule
Chenango County Code Enforcement Building Permit, Fire Inspection and Operating Permit Fee Schedule Building Permit Exceptions: Buildings being used solely for the purpose of agriculture. As per Agricultural,
Errata has been identified as follows:
2009 IFC Performing Commercial Fire Inspections Inventory Number: 1424S09 Second Printing; July 2014 Changes HAVE been made- Third Printing: September 2014 Errata has been identified as follows: 1. Page
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
CHAPTER 9 FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. Provisions of this chapter shall govern the application, design, installation, testing and maintenance of automatic sprinklers, standpipes
Development Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
Georgia State Amendments to the International Fire Code (2012 Edition)
Georgia State Amendments to the International Fire Code (2012 Edition) Georgia Department of Community Affairs Community Development Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231 (404)
A. Fire Protection Plan. B. Access and Parking
Standards for Construction Site Fire Safety For Use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire Code (CFC) These standards are intended to prescribe
SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)
SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon) SECTION SR101 GENERAL SR101.1 General. Group SR occupancies shall comply with the provisions of this appendix
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519
2007 ICC FINAL ACTION AGENDA
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
CHAPTER 67.2 RESIDENTIAL BUILDING CODE
CHAPTER 67.2 RESIDENTIAL BUILDING CODE 1. APPLICABILITY. This Chapter shall have, along with the Code adopted hereby, the scope and applicability set out in said code except as modified by the provisions
WINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES
1. CALCULATION OF PERMIT FEES SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES Permit fees shall be calculated based on the formula given below, unless otherwise specified in this schedule: Permit Fee
BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application
February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management
Single Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME
HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME KITCHEN Keep a working extinguisher in the kitchen. Maintain electric and gas stoves in good operating condition. Keep baking soda on
We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.
September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify
Schedule B to By-law 33-2009
Amended by By-law 8-2016 Note: This consolidation is prepared for convenience only. For accurate reference the original by-laws should be reviewed. Floor Area Calculation Floor area shall: Schedule B to
The replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
WHEN IS A PERMIT REQUIRED?
WHEN IS A PERMIT REQUIRED? Any owner, builder, contractor, or other authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure,
REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET
REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING FIRE SUPPRESSION SYSTEMS APPLICATION PACKET CITY OF NAPERVILLE 400 S. EAGLE STREET NAPERVILLE, Il 60540 PHONE: 630.420.6070 FAX: 630.420.6657 Fire
FIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
City of Bettendorf Fire Alarm System Requirements
City of Bettendorf Fire Alarm System Requirements Section 907 of the 2009 Edition of the International Fire Code (IFC) and Section 10-7-3 of the Municipal Code provide fire alarm requirements. IFC Section
FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall specify where fire protection systems are required and shall apply to the design, installation and
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
Page 25 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
MINNESOTA RULES, CHAPTER 7511 MINNESOTA STATE FIRE CODE
MINNESOTA RULES, CHAPTER 7511 MINNESOTA STATE FIRE CODE 7511.0010 PURPOSE. The purpose of this chapter is to adopt uniform fire safety standards consistent with nationally recognized good practice for
NOW, THEREFORE, BE IT ORDAINED by the Princeton Council as follows:
2013-7 AN ORDINANCE BY PRINCETON CONCERNING FIRE PREVENTION AND AMENDING THE "CODE OF THE BOROUGH OF PRINCETON, NEW JERSEY, 1974 AND THE "CODE OF THE TOWNSHIP OF PRINCETON, NEW JERSEY, 1968". WHEREAS,
TOWN OF ORO VALLEY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE, 2012 EDITION
TOWN OF ORO VALLEY AMENDMENTS TO THE INTERNATIONAL BUILDING CODE, 2012 EDITION The following provision of the International Building Code, 2012 Edition, as published by the International Code Council,
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
SWIMMING POOL, SPA, & HOT TUB GUIDELINES
SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.
Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL 1951 Smith Street, North Providence, RI 02911 Telephone: (401) 383-7717 Fax: (401) 383-8879 John E. Chartier, EFO, CFI State Fire Marshal Rhode Island State
Charter Township of Shelby Harry Reese Building Director
Charter Township of Shelby Harry Reese Building Director Phone: (586) 731-5969 52700 Van Dyke Fax: (586) 803-2099 Shelby Township, MI 48316-3572 E-mail: [email protected] OUTLINE PROCEDURES FOR PRIVATE
MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES
MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES September 13, 2012 MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES WELCOME Exits Restrooms
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
Building Permits: When are they required?
Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building
REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
The following definitions apply with regard to requirements specified in this document:
GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Single Family Residential Building Permit Questions & Answers
Single Family Residential Building Permit Questions & Answers Prepared by Dept. of Public Works Revised 07/01/13 200 East Park Street Edwardsville, IL 62025 (618) 692-7535 (618) 692-7505(Fax) Hours: Monday
Minnesota State Department of Public Safety
Minnesota State Department of Public Safety 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/215-0500 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us Inspection
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
New York City Department of Buildings
The New NYC Building Code Chapter 10 Means of Egress New York City Department of Buildings Technical Affairs Fatma M. Amer, P.E. Copyright Materials This presentation is protected by US and International
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
City of Oviedo Commercial Shell Building Permit Application Guidelines
City of Oviedo Commercial Shell Building Permit Application Guidelines All permit application packages must be complete prior to acceptance. A complete application package shall include the following:
CHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
FIVE YEAR CERTIFICATION REPORT
GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and
Bold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
CITY OF SURREY BY-LAW NO. 6569
CITY OF SURREY BY-LAW NO. 6569 As amended by By-laws No. 7026, 02/01/82; 9960, 03/13/90; 10368, 01/22/90; 10797, 01/28/91; 12268, 04/25/94; 12384, 07/02/94; 12828, 05/13/96; 13171, 07/29/97; 13220, 09/22/97;
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
PERMITS REQUIRED & PERMIT EXEMPTIONS
PERMITS REQUIRED & PERMIT EXEMPTIONS This guideline is intended to assist the applicant in determining what types of construction work require a permit. The 1997 California Uniform Administrative Code,