Chapter 9 N.C. C. N.O. Single-Pole Double-Throw



Similar documents
T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Fig 3. PLC Relay Output

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Conventional Fire Detection and Extinguishant Control System Specification

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

conventional system operation

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Ammonia Detection System Codes and Design Specifications

WD-AMX Water Detection Controllers

Controller Automation, Model II+

Configuring Alarms & Relays in the Enhanced Transformer Advantage

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Water Leak Detection System

SFC-200 SERIES LCD FIRE ALARM PANEL

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Variable Air Volume - VAV

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

INSTALLATION & SERVICE MANUAL. Display Panel

Series B14 Monitor System

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs

HEAT HEAT COOL HEAT PUMP COOL

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Digital Keypad Use s Manual

AlarmSense 2-wire detection and alarm system. Product Guide

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Limited Service Fire Pump Controllers Features

Product Guide CM-Relay

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Alarms Trips: The Ups and Downs

Chlorine Gas Detection System Operation & Maintenance

535T Window Automation System

INSTALLATION / OPERATION MANUAL

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

A1000 Cheat Sheet (Open Loop Vector)

NX Series Inverters. HVAC Pocket Programming Guide

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

CBD-233. Fire Alarm and Detection Systems

PhoneWatch Smart Security System User Manual - Domonial

GTEC transfer switch open transition

T7560A,B,C Digital Wall Module

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Advantium 2 Plus Alarm

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Telefon (+45) Telefax (+45) Installation and operating manual

, User s Manual

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Car Alarm Series 2 B 2 Buttons

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Fire Pump Controllers Remote Alarm Panels

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Safety Requirements Specification Guideline

Manual for Fire Suppression & Methane Detection System

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

CO2 Alarm. Operation. Application

Medical Air Systems: Scroll

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Control/Communicator Installation Manual

HVAC Processes. Lecture 7

Research RF Sputtering Packages

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

Inwall Room Temperature Unit

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

EATON Diesel Plus Diesel Engine Fire Pump Controller

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

GSM HOME SECURITY SYSTEM

RAINCONTROL LCD Special

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Nicholas Mezei CSCI 6448 OOA&D Homework #3: Use Cases. Use Case Diagram: Home Security System. Alarm System

User and installation manual

Electrical Symbols and Line Diagrams

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

The Child Reminder System Installation Manual

PAC1 Door Access Controller

S4000TH HART. HART Communication Manual

MSL1000 Monitored Serial Link Interface Manual V1.01

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

GAE953 Electrical Alarm Unit 19" with Indicator

Back-UPS Pro 1300/1500 Installation and Operation

Model SRMD Setra Remote Monitoring Display

Transcription:

rather than providing multiple choices. The sensor modules used may only be suitable for use with the matching controller so it is wise to read the specifications to make sure the unit suits your application. Among the most common multichannel controllers are 4- and 8-channel versions. These units sometimes incorporate a single display which either displays each channel sequentially, displays a designated channel, or displays the channel with the highest reading. Other designs incorporate an individual display for each channel providing the obvious advantage of allowing you to view the readings of all channels simultaneously. Displays can be either LCD or LED. LED displays are generally easier to read but also consume more power than LCD displays. However, LED displays can be designed to pulse at a high frequency, which is not perceptible to the human eye and which allows it to consume considerably less power. LCD displays have narrower tolerance in operating temperature and are damaged by longterm exposure to the sun s ultraviolet rays. Alarm Relay Contacts Controllers typically provide two- or three-relay contacts, which are used to activate alarm lights, horns, or other devices when gas concentrations exceed preset alarm thresholds. As shown in Figure 7, relay contacts work much the same way as a light switch. Relay Control Circuit Relay Activation Coil N.C. C. N.O. Single-Pole Double-Throw Fig. 7 A Form C Relay Contact. N.C. stands for normally closed; C stands for common, which switches between the two contacts; and N.O. stands for normally open. CONTACT FORMS There are several ways the relay contacts are expressed. Form A Contacts: a single-pole, single-throw, normally open contact. This is the same as a simple switch. Form B Contacts: a single-pole, single-throw, normally closed contact. Form C Contacts: a single-pole, double-throw, changeover from normally open to normally closed or vice versa. 123

Hazardous Gas Monitors Relays can be either single-pole, double-throw (SPDT) or double-pole, double-throw (DPDT). The difference is that SPDT relays have only one contact set while DPDT relays have two contact sets. Relay contacts are normally rated from 3 to 5 amperes resistive at 240 VAC. Generally, this is sufficient to handle most audible and visual alarm devices. However, in cases where the current requirements are higher than the relay contact rating, a second relay with a higher contact rating can be employed. The first relay can be used to drive the second relay, enabling machinery such as exhaust fans to be powered. It is important to check contact ratings prior to use. Solid-state relays have lower contact ratings and a smaller physical size. The power required to activate these relays is also lower. Figure 8 shows the contact arrangement for a visual or an audible alarm (A) and connection to a second relay for a higher power application (B). Power Power Second Relay AC Source Alarm Device Electrical Motor A. Connecting an Alarm Device B. Connecting to a Second Relay Fig. 8 Relay Connections In most cases, relay contacts are deactivated or open under normal conditions. However, this condition can be reversed and the relay can be activated under normal conditions. This arrangement is called a fail-safe configuration and it enables alarms to be tripped in case of a power failure. Alarm Settings Alarm level set points can be implemented in various ways. A simple way is to have the alarm levels pre- 124

set at the factory, leaving no option for the user to adjust the alarm set points. However, in most designs, two or three alarm levels are provided which are, in fact, user adjustable. These alarm levels are provided in a variety of ways, as discussed next. (A) DIP switch By employing an 8-segment DIP switch, for example, alarm levels from 0-100% can be divided into 256 increments, providing the ability to set precise alarm levels. It is necessary to have a separate DIP switch for each alarm setpoint. (B) Preset Button A zero-to-full scale signal is produced using a momentary pushbutton that can be activated during the alarm setup process. An alarm level is simulated and a potentiometer is used to set the actual alarm level. Each alarm requires a separate potentiometer. This procedure is simple and requires only the use of a small screwdriver. (C) Microprocessor With controllers that are microprocessor-based, alarm levels can be set by pushbuttons or by magnetically operated switches on the front panel according to the instructions provided with the unit. Alarm Processing A small gas monitoring system with a few sensors monitoring a relatively small area typically has a simple alarm system. Controllers often provide at least two sets of alarm contacts: one to activate a low alarm device such as a beacon and one to activate a high alarm device such as a horn. The controller has indicators such as LEDs that illuminate when relay contacts are activated. In some cases, controllers have audible alarms built into them. With monitoring systems that have multiple sensors, relay contacts are often com- 125

Hazardous Gas Monitors mon to all sensors. Thus, if any of the sensors exceed a preset alarm threshold, the corresponding alarm relay will be activated. Acknowledgment of alarms is accomplished via a momentary switch which is used to silence audible alarm devices while leaving the visual alarm active until the alarm condition disappears. Relays can be either latching or nonlatching, depending on how the relay tripping circuitry is designed. Typically, a simple jumper wire connector is used to make the relay either latching or nonlatching. A nonlatching relay will turn off the alarm device once the alarm condition is gone. A latching relay, on the other hand, will stay activated until the acknowledge button is pressed, thus resetting the relay. The use of a time-delay relay can be quite useful for some applications. For example, in a parking garage, it is typical to activate a low alarm if the concentration of CO reaches 50 ppm and a high alarm if the concentration exceeds 100 ppm. Parking garages present a relatively small, confined area for monitoring. They often contain high density parking and low ceilings. Thus, alarm levels can be easily exceeded. Even a car driving by the sensor can possibly activate an alarm. This can create frequent false alarms which can become a nuisance. By employing a time-delay relay, alarms are not activated unless alarm levels are continuous for a predetermined length of time, such as 3 minutes. For example, if 50 ppm of CO is still present after 3 minutes, the warning relay is activated and a low speed exhaust fan is turned on. When the CO concentration drops below 50 ppm, the warning relay is then deactivated and the fan is shut off. If the CO concentration exceeds 100 ppm, a high speed ventilation fan is activated and a 15-minute timer is started. If the CO level is still over 100 ppm after 15 minutes, the timer will activate a relay to turn on an audible or visual 126

alarm advising of the situation. The time delay relay is used to prevent frequent activation and deactivation of fans due to momentary traffic or other causes. This conserves energy, reduces maintenance, and increases the life expectancy of the fans. In computer-controlled systems, alarm processing is greatly simplified. The monitoring software can provide time delays for the relays, voting from multiple sensors (which determines the alarm to be activated based on the number of sensors at alarm), and many other alarm options that can be useful for many applications. Calibration The most important function performed by the controller is calibration. It is a routine maintenance procedure that the user must perform in order to ensure the proper operation of the sensor. A simple conventional technique is to use potentiometers to set the zero and span adjustments. However, this does require access to the calibration potentiometers and use of a screwdriver. With a microprocessor-based controller, this same function can be accomplished via a keypad with up and down functions. This allows for minimum operator interaction. The procedure is as follows: 1. Select the calibration gas concentration, which is the concentration of the gas you intend to apply to the sensor. 2. Next, apply the calibration gas. An indicator will come on to notify you to apply the gas. When the reading reaches a stable point, another indicator will display done. At this time, the calibration gas is removed and the calibration is complete. As discussed earlier, magnetic keypads can be employed in hazardous areas where access to keypads is difficult. Additionally, some designs incorporate remote controls similar to those used on TV sets but they must be designed to meet the demands of hazardous area electronics. This allows the adjustments to be made with- 127