THE GREEN DATA CENTER



Similar documents
Utilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency

Data Center Power Consumption

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Convergence of Complexity

Global Green Data Center Best Practices In Action

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data center upgrade proposal. (phase one)

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Re Engineering to a "Green" Data Center, with Measurable ROI

Office of the Government Chief Information Officer. Green Data Centre Practices

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

Energy Performance Optimization of Server Room HVAC System

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Benefits of. Air Flow Management. Data Center

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Data Center Equipment Power Trends

DataCenter 2020: first results for energy-optimization at existing data centers

Why Data Center Design and Innovation Matters

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

- White Paper - Data Centre Cooling. Best Practice

U.S. Department of Energy, National Renewable Energy Laboratory, IT Sustainability Case Study

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

HP Data Center Efficiency For The Next Generation. Pete Deacon Canadian Portfolio Manager Power and Cooling Services

Reducing the Annual Cost of a Telecommunications Data Center

VISIT 2010 Fujitsu Forum Europe 0

How To Improve Energy Efficiency In A Data Center

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Data center lifecycle and energy efficiency

It Pays to Know Your Data Center: Saving Money through Increased Efficiency

Case study: End-to-end data centre infrastructure management

ICT and the Green Data Centre

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center

AbSTRACT INTRODUCTION background

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Adaptive Cooling in Data Centers. Silicon Valley Leadership Group Energy Efficient Data Center Demonstration Project October, 2009

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

abstract about the GREEn GRiD

Can you afford to ignore energy costs of IT infrastructure? A practical guide to more efficient data operations. Powering IT

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Green Data Centre Design

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Data Centre and ICT Energy Metrics - The View from Australia

Environmental Data Center Management and Monitoring

Data Center Facility Basics

Power and Cooling for Ultra-High Density Racks and Blade Servers

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Data Center Lifecycle and Energy Efficiency

Greener Pastures for Your Data Center

Analysis of data centre cooling energy efficiency

Data Center Components Overview

Data Center Infrastructure Management: ERP for the Data Center Manager

Boosting the Energy efficiency of a Server Room: experimental + virtual approach.

Managing Data Centre Heat Issues

Data Center Energy Profiler Questions Checklist

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Pursuing Operational Excellence. Better Data Center Management Through the Use of Metrics

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

Impact of Virtualization on Data Center Physical Infrastructure White Paper #27. Tom Brey, IBM Operations Work Group

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Data Center Technology: Physical Infrastructure

Using CFD for optimal thermal management and cooling design in data centers

Greening Commercial Data Centres

KWE Basic Philosophy. As of March 2010, KWE is ISO14001 certified at 6 locations in Japan and 8 locations overseas

Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

Data Centre Outsourcing a Buyer s Guide

Reducing Data Center Energy Consumption

Green Computing: Datacentres

Benefits of Cold Aisle Containment During Cooling Failure

How To Power And Cool A Data Center

The art of the possible.

Top 5 Trends in Data Center Energy Efficiency

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Green Computing: Datacentres

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Jan Kremer s Data Center Design Consultancy

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

WHITE PAPER. Creating the Green Data Center. Simple Measures to Reduce Energy Consumption

An Introduction to Cold Aisle Containment Systems in the Data Centre

How To Improve Energy Efficiency Through Raising Inlet Temperatures

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.

W H I T E P A P E R. Computational Fluid Dynamics Modeling for Operational Data Centers

HPC TCO: Cooling and Computer Room Efficiency

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Best Practices. for the EU Code of Conduct on Data Centres. Version First Release Release Public

Data Center Energy Efficiency Looking Beyond PUE

Why Energy Management Is Driving Adoption of Data Center Infrastructure Management Solutions

How To Run A Data Center Efficiently

Transcription:

GREEN IT THE GREEN DATA CENTER WHERE ECOLOGY MEETS ECONOMY We truly live in an information age. Data Centers serve a very important purpose they provide the global community with nearly unlimited access to almost any kind of information we can imagine. The problem is that they consume great amounts of power, which can cause emissions that impact our environment. The argument can be made that the Data Center itself can facilitate enough online transactions to prevent people from using their cars or consuming precious resources that will more than outweigh the impact of running the computing equipment necessary to serve data across the net. But, we can do more to protect our environment. Eco-friendliness is mission-critical to our future. That said, the industry feels that the way forward is to make Data Centers GREEN. There are a number of initiatives that Wipro supports in this paper to help foster the convergence between the economy of conserving power and the ecology of maximizing computing resources to reduce environmental impact. WIPRO INSTITUTE FOR INDUSTRY RESEARCH

Abstract We truly live in an information age. Data Centers serve a very important purpose they provide the global community with nearly unlimited access to almost any kind of information we can imagine. The problem is that they consume great amounts of power, which can cause emissions that impact our environment. The argument can be made that the Data Center itself can facilitate enough online transactions to prevent people from using their cars or consuming precious resources that will more than outweigh the impact of running the computing equipment necessary to serve data across the net. But, we can do more to protect our environment. Eco-friendliness is mission-critical to our future. That said, the industry feels that the way forward is to make Data Centers GREEN. There are a number of initiatives that Wipro supports in this paper to help foster the convergence between the economy of conserving power and the ecology of maximizing computing resources to reduce environmental impact. This paper will critically examine the means to maximize your Data Center s efficiency by providing you with a green perspective of your computing environment. Our goal is to give you the tools so you don t waste unnecessary power serving applications people don t use. Going green also means increasing the effectiveness of power consumed in cooling the systems of your Data Center. Once you are able to look at your entire Data Center environment it becomes clear how you can make it operate leaner and more efficiently. The way forward is to follow a green path where no processing cycle goes to waste. The result allows you to provide the same level of information from your Data Center, but with significantly less environmental impact. Wipro Council for Industry Research

Contents Introduction 1 Environmental Impact 1 What if... 1 How does Wipro define a "Green" Data center? 2 Green Data Center metrics 2 How to make the Data Center greener 3 Reduce Wasted Energy 3 Consolidation and Virtualization 3 Managing Energy Efficiency 5 Capacity Planning 5 Conclusion 6

Introduction Both business and environmental goals are merging. Reducing both cooling and energy consumption equates to money saved. Companies go green not just because it is the right thing to do or that it is expected but because it reduces costs and increases earnings potential. Reducing the power requirements for Data Centers can mean less operating expenses and greater efficiency. A Data Center answers the fundamental need for information. You can accomplish this goal by being good to the environment as well as your bottom line. This paper will demonstrate how going green is good for both the economy as well as the ecology! In today s environment, it is very clear that we must go green. However, following the path is not always easy. Many companies are either highly encouraged or forced to go green sooner. This is often due to regulations imposed by governmental agencies. Environmental Impact In the next couple of years, Data Centers are likely to release as much carbon in the atmosphere as the entire airline industry. This often makes Data Centers a target of environmentalists. However, it is important to note that over the long run, the byproducts resulting from a Data Center are far less damaging than the alternative. A Data Center answers the fundamental need for information. You can accomplish this goal by being good to the environment as well as your bottom line. This paper will demonstrate how going green is good for both the economy as well as the ecology! What if For example, let s say ebay did not exist. People would find it necessary to get in their cars and physically drive to the auction house. The emissions produced by all of these vehicles would far exceed the emissions produced from a Data Center. The idea is that a good Data Center can digitize multiple business processes in an online environment as opposed to the real world. The end result is that Data Centers produce a more ecologically friendly environment that actually does good. Wipro Council for of Industry Research 10 1

How does Wipro define a Green Data Center? POWER Ecologically responsible members of an organization look to define an accurate Its all about reducing the amount of emissions by maximizing the usefulness of the data center so that no energy cycle goes to waste. measurement that combines all the topics covered in this white paper to produce work with the greatest efficiency possible. Wipro is working to define a green data center with a metric than can determine the good ratio of useful work completed vs. ecological impact caused to the environment. Green Data Center Metrics What is a good metric to measure a green Data Center? Wipro s recommended metric is the Power Usage Effectiveness, which is known as the Green Grid standard. Determining and improving this metric will help the organization determine and create a more efficient computing model. This translates to delivering more effective services for every dollar spent. This measurement determines the effectiveness of your Data Center by measuring the energy used by the IT equipment as well as all the ancillary equipment.. The objective is to make the environment better while also getting useful work done. Total Facility Power (TFP) is the power being provided to the Data Center Total IT Equipment Power (IEP) is the power used by the IT equipment in the Data center such as Storage equipment, Servers, Networking equipments, Desktops, Laptops, KVM Switches, and Display Units etc. Considering increased computing demands as well as high-density computational environments, the power distribution defined by PUE is the most critical factor. For example, if you re PUE score is 2, then the Data Center s power demand is two times greater than the energy required for powering the IT equipment. A PUE value approaching 1.0 indicates 100% efficiency (i.e. All Power used by IT Equipment only), which is however impossible to achieve, since some power would be taken up by ancillary equipment, Data Center lighting and due to distribution losses. You might ask, How much did I impact the environment for every unit of useful work accomplished by my Data Center? It really isn t measuring how much you degrade the environment, but rather reducing the amount of emissions by maximizing the usefulness of the Data Center so that no energy cycle goes to waste. PUE = TOTAL FACILITY POWER TOTAL IT EQUIPMENT Wipro Council for Industry Research 2

Wipro s Recommendation Wipro s recommended PUE for a Green Data Center is in the range of 1.4 to 1.6. When the PUE increases beyond 1.6, it is indicative of the need to improve energy efficiency. How to make the Data Center greener i. Reduce Wasted Energy There are ways in which you can make your Data Center greener just by getting rid of server applications that eat energy, but are not producing any business benefits. Consolidation of multiple applications and application instances on a single server provides numerous benefits which include increased server utilization, Generally about elimination of redundancies, 10% of a company s increased performance and reduced applications are not maintenance costs. This would doing any useful work. eliminate the applications which exist in the inventory and are not being used. Generally about 10% of a company s applications are not doing any useful work. There could also be redundancies in IT utilisation as a by- product of mergers and acquisitions which need to be rationalized. scores for business value, technical value, cost and risk Identify opportunities to decommission, migrate, consoli date and modernize, based on the scores Lastly, design an application life cycle assessment or APM process integrated with internal investment budgeting and control ii. Consolidation and Virtualization Virtualization can make your Data Center leaner just by driving server utilization up. Most applications are running on machines with more horsepower than the program could ever possibly use. You can solve this problem by running multiple applications on just one server running virtualization software. Instead of running 10 servers at only 5% utilization, you can run just one server running at 80% utilization and unplug all the rest. Wipro Recommendations Wipro offers a comprehensive Application Rationalization solution that addresses both IT and Business problems through an end-to-end transformation approach. The recommended steps are: Perform a detailed analysis of the application inventory and build a repository of application inventory Map applicatations Conduct a 360 degree assessment and develop Wipro Council for Industry Research 3

Case Study Company Location Objective Goal Revenue Personnel Global Locations Power Transmission & Distribution, Retail Power, and Natural Gas UK Outsource their Data Center Management and Transforamation Factor Environmental Parameters into their plans Over $1 Billion (USD) Employs over 1500 people 20 subsidiaries in the UK In the following case, Wipro has taken several prominent initiatives to reduce the Data Center PUE. The client had an IT estate where the Total Facility Power was 1259 KWh (including power used both by IT equipment as well as ancillary items such as chillers and lighting), then the total power consumed ONLY by the IT equipment is 547 kwh generating a PUE value of 1259/547= 2.3. In the following chart, you can see the percentage impact of various Consolidation and Virtualization initiatives on the PUE. In the below graph, weightage is based on Wipro s industry expertise. This metric is represented that resolving any one of these initiatives can reduce PUE by the corresponding percentage on the graph. This percentage can vary proportionally to the Data Center volumetric. This client reduced 80% Windows Based Intel Servers through the consolidation of 47 Wintel Servers to 10 Wintel Servers. Initiatives VS. Impact on PUE Storage Consolidation 3.11% Asset Refresh Desktop Virtualization UNIX Consolidation Network Consolidation Wintel Server Virtualization 5.35% 13.83% 16.69% 18.00% 18.59% Weightage Data Center Upgrade 46.00% 0% 5% 10% 15% 20% 25% 30% 35% 40% 45% 50% Wipro Council for Industry Research 4

Energy Savings Resulting from Server Consolidation: DESCRIPTION ORIGINAL REVISED Number of Servers 47 10 Power (kwh/year) 288,204 61,320 Cooling (BTU/Hour) 112,288 23,891 Carbon Emissions 34 7 Racks 5 1 Total Savings 80% Wipro Recommendations Storage, servers, and network equipment can all be consolidated based on both peak and average utilization. Consolidating several underutilized machines into high-end devices as well as rationalizing several instances of Operating Systems, Databases, and Applications can also bring down your PUE. Wipro s Green Data Center deals with end-to-end server, storage, and network technology services. This includes assessments, virtualization planning, evaluation & selection of product solutions, system integration, testing, and management. Energy is also conserved by using components including occupancy sensors, auto vents, ambiators, and building management sensors. iii. Managing Energy Efficiency Usually, running an efficient system, where not a single Watt is wasted, can dramatically cut costs. Chillers and Computer Room Air Conditioners (CRACs) consume a great deal of energy moving air around to keep the Data Center cool. CRACs draw in air and force it under a raised floor. The air then comes out through planned perforated floor tiles. Air is drawn into the server and then evacuated out of the back of the server. The CRAC draws the hot air back into the unit and cools it down for recirculation. Problems can result when hot air is continually drawn back into the server where it can cause damage to the IT equipment. Cooling is one such system which can help reduce the overall Data Center expense. Wipro Recommendations Wipro designs Data Centers for Customers that take into consideration various factors such as the air flow, areas of heat generation and cooling. A few key aspects of Data Center design are: The concept of Hot Aisle Containment can help reduce energy consumption. There will be a self contained glass unit located behind the server row which captures heat. The air conditioning is located either in or above the row designed to take hot air within its enclosure and push it into a general row. The idea is not to move the cold air very far because the air can be cooled right at the source all while using less energy! Repositioning floor tiles to efficiently manage cold airflow Install seals and grommets in the ceiling, walls, and floors (this reduces bypass airflow) Install blanking plates in the server cabinets to direct airflow more efficiently Seal cracks and crevices around power distribution devices Reduce the number of CRAC s by moving cold air where it needs to go instead of cooling the Data Center over capacity. Locate the data center in a place where air or water cooling techniques can be efficiently adopted; the result can be most favorable to economic and ecology considerations. Wipro Council for Industry Research 5

iv. Capacity Planning CIO s face a constant challenge in determining future requirements of hardware and software for a network, datacenter or even a Web site due to the pace of business growth, dynamic changes in the business environment, mergers and acquisitions and even divestments. As a result most Data Center equipment is built for larger capacity than necessary, which again consumes more power than necessary. Usage of an efficient demand management and capacity planning process to ensure availability of the right processing power and storage at the right time will greatly increase the Data Center efficiency. Wipro Recommendations Wipro works with Customers to design, build, integrate, manage and evolve at an optimized demand management and capacity planning process. This process obtains inputs from the Customer s strategic planning exercise and then converts this into an operational IT Plan and hence the Demand. From a technology standpoint, Wipro recommends Thin Provisioning, a green storage technology that dramatically cuts disk capacity, energy, and floor space costs while substantially alleviating storage and system administration on Storage Area Network; Capacity is dedicated and configured in small increments from a single, non dedicated, comprehensively scalable pool enabling customers to provision storage efficiently and without waste. Conclusion We are at the crossroads where ecology meets economy. Data Centers are a very necessary fabric of our IT society. Although critics state that there mere existence can adversely impact our environment, it can be successfully argued in this paper that Data Centers do more good than harm. Without the online nature of information distribution, people would be forced to use far more natural resources just to accomplish daily activities that are now done online. Furthermore, there are a number of techniques described in this paper such as virtualization and cooling conservation that can make a new or existing Data Center work leaner while at the same time being more energy efficient. Data Centers are an important fact of life making them go greener is good for your wallet as well as the environment 6 Wipro Institute Council for of Industry industry Research