1 1 of 5 9/1/2011 1:19 PM AUG 2011 Managing Power Usage with Energy Efficiency Metrics: The Available Metrics and How to Use Them Rate this item (1 Vote) font size Data centers consume an enormous amount of power. According to a detailed study conducted by the U.S. Environmental Protection Agency (EPA) in August 2007, data centers in the U.S. consumed 61 billion kilowatt-hours, or 1.5 percent of the nation s total electricity, in 2006, adding some 40 million tons of CO2 to the atmosphere. That amount is twice what was consumed just six years earlier, and the EPA forecast data center power consumption to double again from 2006 to 2012 a milestone that may have been reached already, according to some estimates. Companies are now paying very close attention to power consumption throughout their data centers. To support this growing need, the industry has created both the metrics and tools required to measure and manage power utilization effectively. This article describes the various rating systems now available and discusses how each can be used to improve energy efficiency in any data center. Before exploring the efficiency metrics, it is important to put power consumption in data centers into the proper perspective. The cost of electricity currently represents about 25 40% of the operational expenditures for the typical data center. Both the U.S. Department of Energy and Gartner have observed that the cost to power a typical server over its useful life can now exceed the original capital expenditure. Gartner also notes that it can now cost over $50,000 per year to power a single rack of servers. This growing electrical demand might be acceptable if all of that power were being put to useful work. But that is not the case, as a considerable amount of power (even more than half) continues to be wasted, with the major cause being underutilized servers. And the growing demand for server capacity (increasing by an estimated 11% annually) ultimately threatens to exceed the total power and/or cooling capacity available in many data centers, forcing costly upgrades or expansion. It is this threat of outgrowing a data center that has motivated organizations to begin monitoring and managing power utilization. Getting Started with Energy Efficiency Metrics One common means for assessing data center energy efficiency is the Power Usage Effectiveness (PUE) rating system. PUE, created by The Green Grid, is the ratio of total power or energy consumed and the power or energy used by the IT equipment. Version 2 of the rating system (PUE 2) permits measuring either power (in kilowatts) or energy (in kilowatt-hours), with a strong preference for the latter. The typical data center today achieves a rating of about 2.0; in other words, only half of the total energy consumed is being used by the IT equipment (servers, storage and networking infrastructure), with the other half going to the
2 2 of 5 9/1/2011 1:19 PM cooling, lights and the inherent inefficiencies in power distribution systems. Another common rating system is Data Center Infrastructure Efficiency (DCiE), which is the reciprocal of PUE: the ratio of the power used by the IT equipment to the total power consumed. To ensure meaningful PUE or DCiE measurements, it is important to collect data often. Frequent measurements are necessary to capture changes in power utilization at different times of year, different times of the day, and most importantly, during periods of peak and low demand. It is also useful to collect information on environmental conditions at the same time, such as humidity, and hot and cold aisle temperatures. A Data Center Infrastructure Management (DCIM) system is a powerful tool for collecting actual and frequent measurements within a data center. The DCIM system handles all of the measuring, calculating, averaging and comparing automatically, enabling the organization to establish a baseline and to determine the progress toward meeting energy efficiency goals. The typical DCIM system supports both the industry standard and popular proprietary protocols used to measure power consumption, which means there are no special agents to install or extra wires to run to measure power at the building, circuit and device levels. Most DCIM systems also measure environmental conditions, such as temperature, humidity and airflow, throughout the data center. Some offer advanced capabilities like auto-discovery, capacity planning, building management system (BMS) integration, sophisticated yet intuitive dashboards, comprehensive reporting and more. The best ones provide real-time monitoring, advanced analytics and the ability to automate processes in cooperation with load-balancing or virtualization systems to continuously match server capacity with demand. The more accurate the PUE measurements become, the more necessary it is to have a DCIM system. The reason exists in the granularity of the four PUE categories, and reporting PUE results now requires specifying which category is being used. The first and least-accurate category (PUE0) measures IT power consumption (kw) at the output of the uninterruptible power supply (UPS), and it should be taken at the peak. The remaining three categories all measure the actual energy consumption (kwh) of the IT equipment at progressively more granular levels: PUE1 at the UPS output, PUE2 at the power distribution unit (PDU) output and PUE3 at the IT equipment input. PUE reporting also just recently started to require actual data collection over 12 months to eliminate seasonal benefits. Improving PUE/DCiE Ratings The EPA has set a target for data centers in the U.S. of a PUE rating between 1.1 and 1.4 (or a DCiE of 0.9 to 0.7). The benefits of reaching this target range can be profound; for example, an improvement in PUE from 2.3 to 1.3 nearly doubles the power available for IT equipment. With today s typical data center having a PUE rating of around 2.0 (or a DCiE rating of 0.5), achieving this level of improvement will probably require a range of initiatives, including: Right-sizing the UPS and power distribution equipment to minimize inefficiencies Eliminating cooling inefficiencies, upgrading the computer room A/C system to allow for variable cooling and/or making greater use of outside air for cooling Adopting a hot/cold aisle configuration (which will involve optimizing the placement of servers in racks and rows) and increasing cold aisle server inlet temperatures to 80.6 F (27 C) as recommended by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Consolidating and virtualizing servers to improve overall utilization Refreshing IT equipment to newer, more power-efficient systems (see additional details below) To help prioritize these measures, and perhaps some other potential power-efficiency initiatives, it is prudent to first establish a solid baseline for the existing data center. A DCIM system can quickly and accurately provide just such a baseline, and the results normally reveal those areas that will offer the most opportunity for improvement.
3 3 of 5 9/1/2011 1:19 PM Improving server utilization through consolidation and virtualization can increase processing power while reducing energy consumption and cooling needs, as well as rack space utilization. But be aware of a possible surprise with seemingly counterproductive results in these situations: the improvement in IT asset efficiency can actually cause PUE to increase because less power is now going to the servers, while the overhead (cooling, lighting, power distribution, and so on) remains largely the same. But such good deeds should not be punished with these false negative ratings. This inherent limitation in PUE and DCiE has led to creation of some other rating systems that more accurately assess efforts to improve energy efficiency in data centers. Improving IT Energy Efficiency The reason PUE and DCiE can produce counter-productive results is that neither rating system takes into account IT energy efficiency. Indeed, using older IT equipment that consumes (and wastes) more power results in an improvement (lower PUE or higher DCiE). To remedy this shortcoming, both McKinsey and Gartner have created more-comprehensive rating systems that take into account IT energy efficiency: Corporate Average Datacenter Efficiency (CADE) and Power to Performance Effectiveness (PPE), respectively. Both systems are designed to help IT managers address the primary source of waste in data centers today: underutilized servers. Average server utilization in the U.S. is 10% or less for dedicated servers and in the range of 20% to 30% for most virtualized environments. CADE, for example, is the product of facility efficiency (in effect, DCiE) and IT asset efficiency, the latter being derived from a combination of the utilization and efficiency of the IT equipment. Organizations that have refreshed, consolidated and/or virtualized servers invariably achieve a significant improvement in the CADE rating, with PUE and DCiE getting either better or worse depending on the circumstances. The best ways to improve CADE and PPE ratings are to utilize more energy-efficient servers and to increase overall server utilization. Organizations routinely refresh aging servers to take advantage of the improved performance made possible according to Moore s Law. But determining the optimal time to refresh particular servers can be a challenge. Newer servers inevitably offer superior price/performance, but can their total cost of ownership (including power consumption as a major operating expense) be justified? And if so, which old servers should be replaced first, and by which new server model(s)?
4 4 of 5 9/1/2011 1:19 PM Selecting the Most Power-Efficient Servers To help IT managers make such choices, the EPA created an Energy Star Rating System for servers and other IT equipment. But Energy Star has a fundamental flaw similar to the one in the PUE and DCiE rating systems: it focuses on the power supply, ignoring the transactional efficiency of the server itself, and it does not factor in the year/age of the equipment. With an average doubling of server performance every two years, this is a serious shortcoming because there is no way to determine what an older server s Energy Star rating means relative to a newer server available today. As a result, to make a more fully-informed decision, IT managers must make estimates using conservative nameplate ratings and performance specifications, which can produce inaccurate and misleading results. To address this shortcoming, Underwriters Laboratories (UL) created a new performance standard based on the PAR 4 Efficiency Rating. PAR 4 provides an accurate method for determining both absolute and normalized (over time) energy efficiency of both new and existing equipment on a transactions per second per watt basis. To calculate server performance using the UL2640 standard, a series of standardized tests is performed, including a Power On Spike test, a Boot Cycle test and a Benchmark test. The Power On Spike test characterizes the initial power surge that occurs when a device is first turned on or plugged in. The Boot Cycle test measures the time from the power off state until the device is fully functional and has stabilized at an idle state. The Benchmark test determines and classifies the server s overall performance and grants the PAR 4 certification for the year of production in one of the following categories: Green (most efficient), Gold (very efficient), Silver (fairly efficient) and Black (low efficiency). These test results can then be used to determine idle and peak power consumption, along with transactions per second per watt and other useful annualized ratings. These metrics provide a very accurate means for IT managers to compare legacy servers with newer ones, and newer servers with one another. Conclusion IT and facility managers can no longer afford to ignore power consumption in the data center. Power is the limiting factor in the typical data center today, and extending the data center s life must now involve managing power more effectively. A capable DCIM system can establish the baseline and track progress toward energy efficiency goals using one or more rating systems (PUE, DCiE, CADE or PPE). DCIM can also help with other related tasks, including maximizing server utilization, reclaiming stranded power, optimizing equipment placement in aisles and racks, and what-if analyses for capacity planning, along with automated procedures to increase the reliability and energy efficiency of a data center. About the Author Clemens Pfeiffer is CTO of Power Assure and is a 25-year veteran of the software industry, where he has held leadership roles in process modeling and automation, software architecture and database design, and data center management and optimization technologies. Last modified on Wednesday, 24 August :18 Read 1046 times Like this? Tweet it to your followers! Published in Architecture Tagged under data center pue energy efficiency
5 5 of 5 9/1/2011 1:19 PM Social sharing RELATED ITEMS (BY TAG) Online Tech Expands Data Center Operations Data Center Consolidation: Balancing Cost-Savings vs. Business Continuity/Disaster Recovery And Now A Data Center World Some Gaps In Energy Ratings The Platinum LEED Data Center From GE Add comment Name (required) (required, but will not display) Website Notify me of follow-up comments Refresh Send JComments Back To Top
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200
Case study: End-to-end data centre infrastructure management
Case study: End-to-end data centre infrastructure management Situation: A leading public sector organisation suspected that their air conditioning units were not cooling the data centre efficiently. Consequently,
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to
Data Center Infrastructure Management: ERP for the Data Center Manager
Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects
Green Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
Why Energy Management Is Driving Adoption of Data Center Infrastructure Management Solutions
May 2011 Why Is Driving Adoption of Data Center Infrastructure Management Solutions Sponsored by nlyte Software Contents Introduction 1 Key Measures 2 Top Trends behind the Data Center Management Challenge
Measuring Energy Efficiency in a Data Center
The goals of the greening of the Data Center are to minimize energy consumption and reduce the emission of green house gases (carbon footprint) while maximizing IT performance. Energy efficiency metrics
General Recommendations for a Federal Data Center Energy Management Dashboard Display
General Recommendations for a Federal Data Center Energy Management Dashboard Display Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
Reducing Data Center Energy Consumption
Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate
Data Centers That Deliver Better Results. Bring Your Building Together
Data Centers That Deliver Better Results Bring Your Building Together 1 Meeting the high demands of your data center Meeting the increasing heat loads associated with growing computational needs requires
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Measuring Power in your Data Center
RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Raritan Measuring Power in your Data Center Herman Chan, Director, Power Solutions Business Unit, and Greg More, Senior Product Marketing Manager There
Increasing Data Center Efficiency through Metering and Monitoring Power Usage
White Paper Intel Information Technology Computer Manufacturing Data Center Efficiency Increasing Data Center Efficiency through Metering and Monitoring Power Usage To increase data center energy efficiency
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
Data Center Energy Use, Metrics and Rating Systems
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley National Laboratory October 31, 2007 Today s s
Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project
Control of Computer Room Air Handlers Using Wireless Sensors Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify
Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators
Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators Awareness of environmental protection issues, has many industry types focusing and pursuing
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer
Harmonizing Global Metrics for Data Center Energy Efficiency
Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology
Australian Government Data Centre Strategy 2010-2025
Australian Government Data Centre Strategy 2010-2025 Better Practice Guide: Data Centre Power June 2013 17/06/2013 4:12 PM 17/06/2013 4:12 PM Contents Contents 2 1. Introduction 3 Scope 3 Policy Framework
Greener Pastures for Your Data Center
W H I T E P A P E R Greener Pastures for Your Data Center 2 Executive Summary Following a green path, once a concept relegated to a small group of environmentalists and the U.S. Environmental Protection
FEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
Global Green Data Center Best Practices In Action
Global Green Data Center Best Practices In Action DOUG WASHBURN VICE PRESIDENT & RESEARCH DIRECTOR September 25, 2013 Four questions I will answer 1 Why is green important to your business? 2 Why is green
DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M
P a g e 1 DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS David Cosaboon, LEED AP O+M Facility Engineering Associates, P.C. 12701 Fair Lakes Circle, Suite
IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009
IT Cost Savings Audit Information Technology Report Prepared for XYZ Inc. November 2009 Executive Summary This information technology report presents the technology audit resulting from the activities
Increasing Energ y Efficiency In Data Centers
The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
How green is your data center?
Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy
CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How
CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning 2009, Raritan Inc. Overview Corporate America is more dependent than ever on computing
Data Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
Applying Data Center Infrastructure Management in Collocation Data Centers
Applying Data Center Infrastructure Management in Collocation Data Centers Infrastructure Management & Monitoring for Business-Critical Continuity TM Applying Data Center Infrastructure Management (DCIM)
StruxureWare TM Data Center Operation
StruxureWare TM Data Center End to end Management (DCIM) software for monitoring, control of power, cooling, security and energy usage from the building through IT systems Part of StruxureWare for Data
CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
Improve competiveness of IDC and enterprise data centers with DCIM
Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM
The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric
Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
Energy Efficiency Best Practice Guide Data Centre and IT Facilities
2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits
Data Center Power Distribution and Capacity Planning:
Data Center Power Distribution and Capacity Planning: Understanding what you know and don t know about power usage in your data center 2009, Raritan Inc. About This Series Raritan, a leading provider of
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
Benchmarking results from Indian data centers
Benchmarking results from Indian data centers Data Center Energy Efficiency 24 February, ACREX 2011, New Delhi Madhav Kamath. A Energy Efficiency Finance Lead USAID ECO-III Project Data Center Benchmarking
DATA CENTER ASSESSMENT SERVICES
DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to
AIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
Server Technology, Inc.
Server Technology, Inc. Cabinet Power Monitoring, Management & Control Within the Data Center White Paper STI-100-011 2010-Sept-27 by Calvin Nicholson, Senior Director Software and Strategic Alliances,
How To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
Design Best Practices for Data Centers
Tuesday, 22 September 2009 Design Best Practices for Data Centers Written by Mark Welte Tuesday, 22 September 2009 The data center industry is going through revolutionary changes, due to changing market
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
Energy Management Services
February, 2012 Energy Management Services Data centers & IT environments are often critical to today s businesses, directly affecting operations and profitability. General & Mechanical Services has the
SoSe 2014 Dozenten: Prof. Dr. Thomas Ludwig, Dr. Manuel Dolz Vorgetragen von Hakob Aridzanjan 03.06.2014
Total Cost of Ownership in High Performance Computing HPC datacenter energy efficient techniques: job scheduling, best programming practices, energy-saving hardware/software mechanisms SoSe 2014 Dozenten:
Environmental Data Center Management and Monitoring
2013 Raritan Inc. Table of Contents Introduction Page 3 Sensor Design Considerations Page 3 Temperature and Humidity Sensors Page 4 Airflow Sensor Page 6 Differential Air Pressure Sensor Page 6 Water Sensor
Understanding the Promise of (DCIM)
Understanding the Promise of Data Center Infrastructure Management (DCIM) Chuck Kramer, RCDD, NTS, CDCP, CDFOM Senior Solutions Consultant Emerson Network Power What is DCIM? The monitoring, collection
White paper. Control room convergence: Merging industrial monitoring and control systems with data center operations
White paper Control room convergence: Merging industrial monitoring and control systems with data center operations Data centers as an industry Projected increase 2011-2012: Number of data center facilities:
Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens.
Datacenter Clarity LC for colocation owners and tenants The Data Center Infrastructure (DCIM) solution from Siemens siemens.com/dcim Increased efficiency through Datacenter Clarity LC As organizations
Top 5 Trends in Data Center Energy Efficiency
Top 5 Trends in Data Center Energy Efficiency By Todd Boucher, Principal Leading Edge Design Group 603.632.4507 @ledesigngroup Copyright 2012 Leading Edge Design Group www.ledesigngroup.com 1 In 2007,
Using CFD for optimal thermal management and cooling design in data centers
www.siemens.com/datacenters Using CFD for optimal thermal management and cooling design in data centers Introduction As the power density of IT equipment within a rack increases and energy costs rise,
5 Reasons. Environment Sensors are used in all Modern Data Centers
5 Reasons Environment Sensors are used in all Modern Data Centers TABLE OF CONTENTS 5 Reasons Environmental Sensors are used in all Modern Data Centers Save on Cooling by Confidently Raising Data Center
RACKWISE Data Center Manager
RACKWISE Data Center Manager For more information on RACKWISE Data Center Manager, visit or contact us at [email protected] or (888) 818-2385 Corporate Headquarters 2365 Iron Point Road Suite 190 Folsom,
abstract about the GREEn GRiD
Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
Smarter Data Centers. Integrated Data Center Service Management
Smarter Data Centers Integrated Data Center Service Management Approx. 3.500 ton CO² is generated by: Diesel Car-6l /100 km 20.000 km Airplane 5 * Brussels-Barcelona Server, 1.5 A, 24*7*365*3.000 Kwhr
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda
Data Center Infrastructure Management: How to Optimize Data Center Operations
Data Center Infrastructure Management: How to Optimize Data Center Operations Khaled Nassoura, PE [email protected] General Manager Raritan, Inc. Question of the Day Question: Would any CFO run
Datacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
Reducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
The Green Data Center
The Green Data Center Energy Efficient Computing In The 21st Century The Green Data Center: Energy Efficient Computing In The 21 st Century Matt Stansberry Site Editor TechTarget [email protected]
Power Management. Raritan Description. http://www.raritan.com/products/power-management/
Raritan Description Raritan is a proven innovator of power management, infrastructure management, KVM and serial solutions for data centers of all sizes. In more than 50,000 locations worldwide, our hardware
The Efficient Data Center
WHITE PAPER Data Center Efficiency and Optimization Data Center Management The Efficient Data Center Using data center instrumentation and server refresh to optimize compute performance in constrained
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers
Energy Efficiency and Availability Management in Consolidated Data Centers
Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal
BEYOND DIAGRAMS AND SPREADSHEETS DATA CENTER INFRASTRUCTURE MANAGEMENT (DCIM)
BEYOND DIAGRAMS AND SPREADSHEETS DATA CENTER INFRASTRUCTURE MANAGEMENT (DCIM) THE CHALLENGE. Solve complexity The trend for consolidation and construction of ever- larger data centers has been basically
How High Temperature Data Centers and Intel Technologies Decrease Operating Costs
Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 1 Measuring PUE at Dedicated Data Centers 15 July 2010 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations
THE GREEN DATA CENTER
GREEN IT THE GREEN DATA CENTER WHERE ECOLOGY MEETS ECONOMY We truly live in an information age. Data Centers serve a very important purpose they provide the global community with nearly unlimited access