Three Steps To Perfectly Green



Similar documents
DATA CENTERS BEST IN CLASS

Measuring Power in your Data Center

Uptime Institute Symposium 2010

Power Analytics: A Model-Based Approach to Availability, Energy, and Resource Management

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Advantages of Micro-container-based Data Center Infrastructure Simon Rohrich, Founding Member, Technology Evangelist

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

VISIT 2010 Fujitsu Forum Europe 0

European Business Reliance Centres when Commodity serves Green IT

European Code of Conduct for Data Centre. Presentation of the Awards 2013

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Data Center Facility Basics

Recommendations for Measuring and Reporting Overall Data Center Efficiency

DataCenter 2020: first results for energy-optimization at existing data centers

Recommendations for Measuring and Reporting Overall Data Center Efficiency

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging

The Use of Fresh Air in the Data Centre

World s Greenest High Performance Data Center

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

ICT and the Green Data Centre

5 Simple Steps to Maximizing the Business Value of Your Datacenter

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Zen Internet Case Study

Greening Commercial Data Centres

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Datacenter Efficiency

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Data Centers: Definitions, Concepts and Concerns

As close to perfection. development and production. Modular data center

Increasing Energ y Efficiency In Data Centers

Modular Chiller Plants for data centers. Downtime isn t acceptable

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Table of Contents. 2 Why IT Organizations Everywhere Need to go Green. 3 Greening the Data Center

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Excool grows rapidly as datacenter operators seek greener, cheaper cooling

Common mistakes in datacentre planning

Green Computing: Datacentres

How To Understand The Data Center Bubble In India

Deep Dive Think Tank: Energy Costs and Strategies for Reduction

Green Computing: Datacentres

Why Data Center Design and Innovation Matters

Managing Data Centre Heat Issues

How To Improve Energy Efficiency Through Raising Inlet Temperatures

TelecityGroup plc. Outstanding data centres. Expertise you can trust.

Tim Facius Baltimore Aircoil

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

DC Pro Assessment Tools. November 14, 2010

THE WORLD S MOST EFFICIENT DATA CENTER

Combi Unit Genius. The energy efficient Building Service Centre

Energy Savings in the Data Center Starts with Power Monitoring

Data Centers That Deliver Better Results. Bring Your Building Together

Raising Inlet Temperatures in the Data Centre

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Drives and motors. A guide to using variable-speed drives and motors in data centres

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

U.S. Department of Energy, National Renewable Energy Laboratory, IT Sustainability Case Study

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

How to Meet 24 by Forever Cooling Demands of your Data Center

An Oracle White Paper November Achieving New Levels of Datacenter Performance and Efficiency with Software-optimized Flash Storage

Advania Cloud Co-location

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

// GREEN IT / DATA CENTRE BUILD GREEN

The Pros and Cons of Modular Systems

European Code of Conduct for Data Centre. Presentation of the Awards 2016

White Paper: Free Cooling and the Efficiency of your Data Centre

HPC TCO: Cooling and Computer Room Efficiency

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Data Center Infrastructure Management: ERP for the Data Center Manager

Reducing Data Center Energy Consumption

I don t want to move to the Arctic - a HPC Data Center Take on PUE and Energy Efficiency

Insights. Special Convention Issue: Innovation. Education. Success. The magazine for today s electrical and systems contractor

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

DATA CENTER ASSESSMENT SERVICES

National Grid Your Partner in Energy Solutions

Energy Efficiency and Availability Management in Consolidated Data Centers

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

Data Center Power Consumption

Metrics for Data Centre Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Improving Data Center Energy Efficiency Through Environmental Optimization

Measure Server delta- T using AUDIT- BUDDY

Mechanical insulation to increase building efficiency. Saving money, energy and the planet.

Dell s Next Generation Servers: Pushing the Limits of Data Center Cooling Cost Savings

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Office of the Government Chief Information Officer. Green Data Centre Practices

Scalable. Affordable. Flexible. Fast.

How a Ground Source Heat Pump Works for a School or College

Transcription:

R E S E A R C H U N D E R W R I T E R W H I T E P A P E R LEAN, CLEAN & GREEN Deerns Consulting Engineers Three Steps To Perfectly Green By Wouter M. Kok, Manager, Cleanroom, Laboratory, and Data Center Department Deerns leads the way in making data centers greener, by reducing the amount of energy needed for cooling by an impressive 80 percent. Publisher s Note: This co-branded and copyrighted paper is published for inclusion in formal compilation of papers, presentations, and proceedings known as The Path Forward v4.0 Revolutionizing Data Center Efficiency of the annual Uptime Institute s Green Enterprise IT Symposium, April 13-16, 2009, New York City. It contains significant information value for the data center professional community which the Institute serves. Although written by a research underwriting partner of the Institute, the Institute maintains a vendor-neutral policy and does not endorse any opinion, position, product or service mentioned in this paper. Readers are encouraged to contact this paper s author(s) directly with comments, questions or for any further information.

It s a well-known fact: data centers use enormous amounts of energy. Apart from the energy used by computers, an almost equal amount is used by the infrastructure of the data center, particularly for cooling purposes. Often, this secondary energy use is over 90 percent compared with the primary energy used by the servers. In other words, an overall power usage efficiency (PUE) of 1.9. As a first step, tuning the traditional data center infrastructure for free cooling and energy efficiency has led to some 25 percent less cooling energy usage, leading to a PUE of 1.7 or, in specific data centers, 1.5. Obviously, much more needs to be done to reach the goal of greener data centers. Recently, Deerns has developed the second step by designing smart "add-ons" to the data center infrastructure. This has resulted in an additional 50 percent reduction in cooling energy, leading to PUEs of 1.35 to 1.26. Taking advantage of lower air temperatures that occur during nights and winters, Deerns designed a number of innovative systems such as aquifers and surface water to store this surplus cold. Deerns has now identified a third step and is shaping the next generation of data centers. Deerns GC-DC (Green Cooling for Data Centers) system combines a number of advantages: Eliminating 80 percent of "standard" cooling infrastructure, leading to an additional 50 percent saving on cooling energy (as compared to step 2) and a PUE of 1.15 Combining simple, proven technologies with this new concept leads to excellent reliability and availability Investment costs are below "traditional" data centers, leading to zero pay-back periods Modularization leads to increased phasing of the investments for the entire cooling infrastructure: payas-you-grow has been made possible, with short realization times Data centers no longer contain any liquids associated with cooling Companies like AMD, Cisco, Microsoft, HP, Sun and Google have united in The Green Grid. One of the goals of this global organization is to promote energy-efficiency in data centers. In early 2008, The Green Grid reported that more than 150 organizations had already joined, including Deerns. In this paper, Deerns elaborates on what has been done in recent years and what are the best options available for any data center developed in the near future. Deerns has identified three steps in the development towards the perfectly green data center. The industry, however, is conservative when it comes to innovations that deviate from traditional infrastructure; operational reliability and safety are of paramount importance, just like the data center s business model. Deerns fully acknowledges this and fulfills these demands: the "green improvements" improve reliability, safety, and the economics of a data center. Three Steps To Green Data Centers Deerns identifies three steps towards green data centers: Step 1. Conventional data center infrastructure concepts, especially those for cooling, can be improved by tuning the infrastructure to minimize energy consumption through a total cost of ownership perspective. This generates a greener data center with less operational expenditures. The tuning to minimize energy consumption from a total cost of ownership perspective, basically optimizing the life cycle cost, is done integrally for the entire cooling system: the recirculation units, pumps, chillers, heat exchangers, and dry coolers or cooling towers. The improved energy consumption results in the ability to use higher outside air temperature for free cooling and a higher energy efficiency of individual components. (See Figure 1.) Introduction Some years ago, the IT sector was calling itself the most environmentally friendly branch in business. Since 2008, that statement is no longer heard. The IT sector, with a growth-rate of more than 20 percent per year, emits almost as much carbon dioxide (CO 2) as the entire aviation sector. It is now time to turn the tide. Hence, everyone is talking about green data centers and what should be done. 2

store cooling energy in winter and during the night in other seasons. Using this stored cold during warmer periods results in a reduction of the PUE to less than 1.35 (at full load, 1.26), and a substantial reduction of the operational expenditures and indeed, the total cost of ownership. Figure 1. Conventional infrastructure The total result is a reduction of 25 percent of the data center s overall energy use: a PUE of approximately 1.7 to 1.5. 1 Step 1 thus leads to a small improvement in the total cost of ownership of the data center, while the reliability and availability remain unaffected. Step 2. Once the basic cooling system is tuned to minimize energy consumption, the next step is to search for improvements in the efficiency of the energy that is used. One method through which this can be accomplished is the storing of cooling energy (e.g., cold water), maximizing the utilization of cheap cold air or cold surface water in relation to daily or seasonal fluctuations. (See Figure 2.) Step 3. With steps 1 and 2, the conventional cooling concept has been stretched to its limit in terms of energy efficiency. Thus, the next step is to rethink the cooling needs of a data center and how to best satisfy those needs. With this goal in mind, Deerns data center specialists have developed the GC-DC concept (Green Cooling for Data Centers, in collaboration with KyotoCooling and Holland Conditioning), an innovative and intelligent new combination of existing, proven technologies. It is, however, a different and much more efficient way of getting the heat outside. Heat Emitted Directly Outside Conventional data centers make use of recirculation units installed in the computer room. These units are forcecooled with water continually pumped through the pipework. In the GC-DC concept, the traditional recirculation units in the computer room are replaced with compartments, which include a heat exchanger and coolers that are installed outside the computer room. With the aid of fans, the air in the computer room is recirculated while it is being cooled by the stationary heat exchanger. The heat is discharged directly outdoors - no direct contact, no mixture nor leakage of air from the computer room with the outside air. And no more cooling liquids anywhere in computer rooms. That is Kyoto -cooling for a data center. (See Figure 3.) Figure 2: Storage of seasonal cooling energy This has been done in a 6,500 m 2 (70,000 ft 2 ) data center for a corporate client in the Netherlands, using an aquifer to 1 The reduction of 25 percent is calculated over the surplus energy compared to server energy, i.e., with a PUE of 1.9 for a conventional data center, a 90 percent surplus on the server energy is consumed by the infrastructure. A reduction of 25 percent leads to 90% x (100%- 25%) = 68%, leading to a PUE of approximately 1.7. Figure 3: The basic principle of GC-DC 3

Due to the much more direct transfer of the heat developed in the computer racks to the outdoor air, free cooling can be used for a much greater part of the year. When the outdoor temperature becomes too high (greater than ca. 21 C / 70 F), 2 the system is aided by a compression cooling unit located outside the computer room. The overall system is built in modular compartments or cooling cells that are totally independent of one another, so full cooling system failures are no longer possible and no water-bearing systems for cooling are located in the computer room: better availability and reliability through simplicity. Because of the modular nature of the system, investment costs for the entire cooling infrastructure can be postponed in line with the growth of energy demand during the operational pay-as-you-grow. (See Figure 4.) Figure 5: PUE over the world for the GC-DC concept The system not only leads to huge savings on cooling costs, but also improves availability and reliability with the same level of investment. (See Table 1.) Figure 4: The modularity of the GC-DC concept Compared to a conventional system, the GC-DC concept reduces the demand for cooling energy by 80 percent; the resulting overall PUE of the data center is approximately 1.15. Even in a hot climate like Phoenix, Arizona, the reduction in cooling energy is approximately 30 percent, with an overall PUE of 1.38. (See Figure 5.) Table 1: Financial information on the GC-DC concept The Bigger Picture 2 Assuming a cold aisle temperature of 25 C / 77 F If the philosophy behind GC-DC is projected to the surroundings of the data center, one not only gets an opportunity to reuse the waste heat of the data center, but an entire sustainable Internet valley can be created. The Lockerbie Data Centres project in Scotland seeks to pursue just this: a sustainable development of the energy chain around the data center. This project combines multiple sustainable power resources with a collection of greenhouses, residential areas and commercial real estate to reuse the heat. In realizing this philosophy, the carbon footprint of the data center and its surroundings is diminished. (See Figure 6.) 4

About the Author Wouter M. Kok, MSc, MMC, is a Manager in the Cleanroom, Laboratory, and Datacenter Department of Deerns Consulting Engineers. After studying Aerospace Engineering at the Technical University in Delft and obtaining a postgraduate degree in Management Consultancy, both in the Netherlands, Wouter Kok began his career at Figure 6: The Green Internet Valley of the Lockerbie Data Centres Conclusion In recent years, a reduction of about 60 percent of cooling energy consumption has been achieved by tuning the system design with respect to energy consumption and by incorporating add-on features for increased efficiency of the energy used. Today, a reduction of 80 percent of cooling energy consumption is possible with the Deerns GC-DC concept. For tomorrow, Deerns is already developing the next step In summary, the GC-DC concept features include - a PUE of 1.15 and 100 percent free cooling up to 21 C / 70 F - improved reliability and availability with no possibilities for total cooling system failure - a completely modular cooling system for improved phasing of the investment - a simpler system with easier maintenance and operation. Deerns Consulting Engineers in 2003. At that time, he quickly proved to be an ambitious and competent consultant. Working on projects for several Dutch universities, Ministries and industries (including KPN Telecom and Equinix, among others), Wouter soon became the Manager of Deerns Cleanroom, Laboratory, and Datacenter Department. One of his greatest achievements has been developing the GC-DC concept (Green Cooling for Data Centers; patent pending). Wouter Kok successfully combines a high level technical background with a sharp mind to improve, innovate and realize data center infrastructures. About Deerns Consulting Engineers Deerns enables clients to recognize their goals of comfortable, safe and sustainable projects. In doing so, Deerns challenges itself and its clients to realize the greenest solutions possible. A highly innovative and cost effective example of this is Deerns critically acclaimed Green Cooling for Data Centers (GC-DC ) concept, which has proven to reduce cooling energy consumption by 80 percent. For more information on this whitepaper or Deerns Consulting Engineers, please write contact@deerns.nl Thus, a company that operates a green data center based on the GC-DC concept has a major competitive advantage due to lower operational expenditures, even without taking into consideration the associated benefits from a social and environmental perspective. The improved phasing of the investment is a valuable asset, especially given the present uncertainties with project finance and sales projections. Basically, GC-DC makes a greener data center the best value proposition for any data center host. About the Uptime Institute Uptime Institute is a leading global authority on data centers. Since 1993, it has provided education, consulting, knowledge networks, and expert advisory for data center Facilities and IT organizations interested in maximizing site infrastructure uptime availability. It has pioneered numerous industry innovations, including the Tier Classification System for data center availability, which serves as a de facto industry standard. Site Uptime Network is a private knowledge network with 100 global corporate and government members, mostly at the scale of Fortune 100-sized organizations in North America and EMEA. In 2008, the Institute launched an individual Institute 5

membership program. For the industry as a whole, the Institute certifies data center Tier level and site resiliency, provides site sustainability assessments, and assists data center owners in planning and justifying data center projects. It publishes papers and reports, offers seminars, and produces an annual Green Enterprise IT Symposium, the premier event in the field focused primarily on improving enterprise IT and data center computing energy efficiency. It also sponsors the annual Green Enterprise IT Awards and the Global Green 100 programs. The Institute conducts custom surveys, research and product certifications for industry manufacturers. All Institute published materials are 2009 Uptime Institute, Inc., and protected by international copyright law, all rights reserved, for all media and all uses. Written permission is required to reproduce all or any portion of the Institute s literature for any purpose. To download the reprint permission request form, uptimeinstitute.org/resources. Uptime Institute, Inc. 2904 Rodeo Park Drive East Building 100 Santa Fe, NM 87505-6316 Corporate Offices: 505.986.3900 Fax: 505.982.8484 uptimeinstitute.org 2009 Uptime Institute, Inc. and Deerns Consulting Engineers, Rijswijk, the Netherlands 6