Advantages of Micro-container-based Data Center Infrastructure Simon Rohrich, Founding Member, Technology Evangelist
|
|
|
- Sylvia Cox
- 10 years ago
- Views:
Transcription
1 RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Elliptical Mobile Solutions Advantages of Micro-container-based Data Center Infrastructure Simon Rohrich, Founding Member, Technology Evangelist This paper shows the advantages of interconnecting self-contained and robust micro-containerized data center modules (data center in a box) packaged inside an inexpensive shell building. Using data provided by Uptime Institute s research and published papers, this paper compares typical legacy data center construction costs with a typical Elliptical Mobile Solutions micro-container deployment. Publisher snote: ThePathForwardv4.0 RevolutionizingDataCenterEfficiency.
2 Introduction This paper compares one megawatt of IT capacity deployed in two different ways. Using Uptime Institute s True TCO (total cost of ownership) Calculator (Koomey, 2007, Uptime Institute), 1 Elliptical Mobile Solutions (EMS) has contrasted a traditional or legacy datacenter facility to a micro data center-based build (including a metal shell building). The purpose of this comparison is to show the savings potential afforded by a micro-container-based infrastructure. The recent Uptime Institute study reveals that the TCO of a Tier 3 or Tier 4 (referring to Uptime Institute s Tier Classification System for determining a data center facility s availability and resiliency) datacenter is $25,000/ft 2. The Institute has determined that each 42U rack of Tier 4 equipment requires 100ft 2 of raised floor including support equipment allocated per rack. The micro data center has 20ft 2 allocated for floor space/ergonomic considerations despite its actual physical foot print of 14ft 2 with all physical support equipment is onboard. Features, Benefits of Micro-Container-Based Infrastructure Enables rapid deployment of a fully functional cost, space, and energy-efficient data center Affordable, scalable infrastructure allows data center operator to automatically micromanage power consumption, cooling delivery and temperature setpoints Technology transfer of enterprise computing to the small to medium business market place Flexible data centers open new market locations Scales to meet changing business needs with pay-as-you-go infrastructure Delivers highly granular, vendor-specific, and optimized server, network, storage, and telecommunications environments Figure 1. Micro-container-based data center versus standard design
3 Typically enables 50 percent lower operating costs than traditional datacenter design and build Provides a high-quality, complete turnkey solution for data center deployment Smaller footprint, higher density W/ft 2 vs. legacy 150W-200W/ft 2 datacenter Vertically increases data center compute density without increasing overall facility footprint Merges facilities infrastructure and IT equipment into one easy-to-manage appliance Modularity and scalability increase efficiency 10 to 15 percent by preventing over- or underbuilds each ultimately more expensive than just-the-right-capacity builds Single-user datacenter relocation Turnkey solution for Health Insurance Portability and Accountability Act (HIPAA) and Sarbanes- Oxley Act (SarbOx) data security compliance Relocatable Adaptive Suspension Equipment Rack (RASER) is transported with pallet jack or forklift with all rack-mounted equipment in place; Self-Propelled Electronic Armored Rack (SPEAR) unit is compact enough to pass through open doorways Earthquake resistant Disaster tolerant Future-proof infrastructure Infrastructure systems are expected to represent about 90 percent of the energy use of IT equipment in 2011 EPA Report to Congress 2007 Data center facilities spend (CapEx and OpEx) is a large, quickly growing and very inefficient portion of the total IT budget in many technology intensive industries such as financial services and telecommunications. Some intensive data center users will face meaningfully reduced profitability if current trends continue. Uptime Institute A new data center for the largest corporations will be required every 3 to 5 years just to keep up with an ever-increasing power consumption. Kenneth G Brill- Executive Director of the Uptime Institute
4 Figure 2. CapEx comparison of legacy data center vs. RASER-based data center infrastructure. CapEx Comparison Tier II DC Tier IV DC RASER Based Tier IV+ Capacity 1MW 1MW 1MW W/Sqft 50W/ft² 100W/ft² 1000W/ft² Notes Tier II =$12,500/KW* Tier IV=$25,000/KW* Racks Raised Floor 15,000ft² 7,500ft² 1000ft² $300/ft² Gross Building Foot Print 26,000ft² 22,500ft² 2000ft² $1100/ft² CapEx 18.5 Million 52.6 Million 4.4 Million 75-90% CapEx Savings *Turner and Brill, Cost Model Dollars per kw and Dollar per Square Foot of Computer Floor 2008 Uptime Institute.
5 Figure 2, continued. OpEx Comparison Tier II DC * Tier IV DC* RASER Based Tier IV+ redundant interconnected containers on VCT floor Total electricity costs $1,043,900 $1,343,900 $650,500 No air handling losses, zero bypass cooling, hot/ cold aisle containment, optimized temperature set points Network fees $500,000 $500,000 $500,000 IT site management staff $390,000 $390,000 $390,000 Facilities site management staff $520,000 $520,000 $0 Maintenance $416,000 $616,000 $200,000 Facilities Maintenance absorbed by product Warrantee Partially absorbed by product Warrantee Janitorial and landscaping $160,000 $160,000 $160,000 Security $702,000 $702,000 $50,000 Turnkey SARBOX/HIPPA compliant Property taxes $144,735 $244,735 $10,000 Total OpEX $3,876,635 4,476,635 1,960,500 Portable Infrastructure not tied to site valuation 50-75% OpEx Savings Conclusions The Holy Grail? Data center infrastructure is becoming a much larger piece of the overall enterprise budget. How much increased overhead is dependent upon how much total budget is spent on facilities and infrastructure, as these are the rapidly inflating factors. Furthermore, as computer performance increases, the costs to cool the equipment increase exponentially as well, compounding the problem. These problems won t go away as computer power and efficiencies increase. Demand is outstripping gains in performance. The demand is driven by the falling price of computer power and consumer demand for digital products/services. Current methods of building data centers aren t sustainable as Moore s Law advances. Converging IT and Facilities into one finely managed entity has long been the goal of data center efficiency thought leaders. Microcontainers with integrated infrastructure support force data center builders and planners to converge these two disciplines on the device level. Enabling technology that merges IT and facility into one device is the Holy Grail of this focus. EMS s unique containerized data centers completely meet this need. Significant savings in deployment, operational, and electrical costs are now realized with this emerging technology. Network-based monitoring/control and virtualization software has required an infrastructure counterpart to realize the market potential of their technologies. RASER and SPEAR micro-containers are at the cutting edge of this technology convergence. As data centers become more expensive to build and increasingly harder and more costly to cool the microcontainer costs remain the same. This effectively reverses the exponential rise in facility and infrastructure costs relative to compute power. Adopters will experience savings through smaller facility footprint; power efficiency; and reduced expense for land taxes, fire suppression systems, security build out, and initial capital investment. All major players in the industry (IBM, Sun, HP, Dell), the Environmental Protection Agency, and engineering groups (McKinsey Group, Turner Logistics) have concluded that data centers must make radical changes to maintain profitability in the face of increasing energy and infrastructure costs each year. They have developed efficient, mobile, and modular data center building
6 blocks to solve these issues. The implementation of these large and expensive solutions is not possible for 90 percent of the business world. A rack- level solution that captures the advantages of containerized computing in a smaller, less expensive footprint is required. Micro-scale containerized data centers are one viable answer. Bibliography Dollars per KW and dollars per square foot of computer floor, Pitt Turner IV, PE with Kenneth Brill The Economic Meltdown of Moore s Law and the Green Data Center, Ken Brill, Executive Director, Uptime Institute Report to Congress on Server and Data Center Energy Efficiency Public Law Revolutionizing Data Center Efficiency 2008, William Forrest,-McKinsey & Company A Simple Model for Determining True Total Cost of Ownership for Data Centers Version 2.1, March 31, 2008, Jonathan Koomey, Ph.D. with Kenneth Brill, Pitt Turner, John Stanley, and Bruce Taylor About the Author Simon Rohrich is a founder and technology evangelist of Elliptical Mobile Solutions. He has served in many seniorlevel capacities primarily in engineering, finance, project management, and marketing. Simon s background is in various technical fields, including telecom, IT, and wireless communication. His multi-disciplinary experience and passion for green technologies have shaped the philosophical underpinnings of Elliptical Mobile Solutions overall product vision. Please contact him with questions or comments at [email protected] About Elliptical Mobile Solutions Elliptical Mobile Solutions was founded in August 2005 as a subsidiary of Elliptical Media to develop innovative product lines designed to stabilize sensitive electronic equipment in a mobile and/or unstable environment. At the core of our designs is a multi-dimensional suspension system that isolates electronic equipment from damaging shock and vibration through a patent-pending combination of pneumatic weight adaptation and magnetorheological/pneumatic dampening. While we are not opposed to incorporating innovative and unique designs into our electronic transport systems, we strive to include field tested and proven commercial off-the-shelf components to improve reliability in a cost effective manner. Elliptical Mobile Solutions is a research and development company that identifies deficiencies in the current state of technology and then offers realistic and commercially viable solutions to remedy those deficiencies. Engineering models are designed, built, and tested within our facilities so that our innovative concepts and system designs may be proven and perfected. Partnerships and alliances are then formed with key individuals/business entities to convert the proven designs from engineering models into commercial offerings. About the Uptime Institute Uptime Institute is a leading global authority on data centers. Since 1993, it has provided education, consulting, knowledge networks, and expert advisory for data center Facilities and IT organizations interested in maximizing site infrastructure uptime availability. It has pioneered numerous industry innovations, including the Tier Classification System for data center availability, which serves as a de facto industry standard. Site Uptime Network is a private knowledge network with 100 global corporate and government members, mostly at the scale of Fortune 100-sized organizations in North America and EMEA. In 2008, the Institute launched an individual Institute membership program. For the industry as a whole, the Institute certifies data center Tier level and site resiliency, provides site sustainability assessments, and assists data center owners in planning and justifying data center projects. It publishes papers and reports, offers seminars, and produces an annual Green Enterprise IT Symposium, the premier event in the field focused primarily on improving enterprise IT and data center computing energy efficiency. It also sponsors the annual Green Enterprise IT Awards and the Global Green 100 programs. The Institute conducts custom surveys, research and product certifications for industry manufacturers. All Institute published materials are 2009 Uptime Institute, Inc., and protected by international copyright law, all rights reserved, for all media and all uses. Written permission is required to reproduce all or any portion of the Institute s literature for any purpose. To download the reprint permission request form, uptimeinstitute.org/resources. Uptime Institute, Inc Rodeo Park Drive East Building 100 Santa Fe, NM Corporate Offices: Fax: uptimeinstitute.org 2009 Uptime Institute, Inc. and Elliptical Mobile Solutions, LLC
Three Steps To Perfectly Green
R E S E A R C H U N D E R W R I T E R W H I T E P A P E R LEAN, CLEAN & GREEN Deerns Consulting Engineers Three Steps To Perfectly Green By Wouter M. Kok, Manager, Cleanroom, Laboratory, and Data Center
The Data Centers of the Future Are Here Elliptical Mobile Solutions The Global Leaders in Micro-Modular Data Centers TThElliptical Mobile Solutions
The Data Centers of the Future Are Here Elliptical Mobile Solutions The Global Leaders in Micro-Modular Data Centers TThElliptical Mobile Solutions In today s rapidly changing information technology (IT)
Measuring Power in your Data Center
RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Raritan Measuring Power in your Data Center Herman Chan, Director, Power Solutions Business Unit, and Greg More, Senior Product Marketing Manager There
How To Design A Data Center
Approaches to Achieve Next-Generation Data Center Joe Li Business Head of Mission Critical Infrastructure Solutions What CIOs should know.. High way to Next-Generation Data Center Energy-Efficiency Scalability
How to Meet 24 by Forever Cooling Demands of your Data Center
W h i t e P a p e r How to Meet 24 by Forever Cooling Demands of your Data Center Three critical aspects that are important to the operation of computer facilities are matching IT expectations with the
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. Overview Data centers are an ever growing part of our economy.
Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant
RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Wright Line Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant Currently 60 percent of the cool air that
Data Center Equipment Power Trends
Green field data center design 11 Jan 2010 by Shlomo Novotny Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. explores water cooling for maximum efficiency - Part 1 Overview Data
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
Increasing Energ y Efficiency In Data Centers
The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
Enabling an agile Data Centre in a (Fr)agile market
Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
Alternative data center power
Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to
opdc Cut your data center OPEX upto 70%
opdc Cut your data center OPEX upto 70% Advantages Configuration Introducing the plug & play On Premises Data Center Introducing - The plug & play on premises data center The is a self-contained data center
Insourcing vs. Outsourcing. Bart Leung Senior Associate, Ehvert Mission Critical
Insourcing vs. Outsourcing Bart Leung Senior Associate, Ehvert Mission Critical 1 Agenda Ehvert Mission Critical Data Centres Then and Now Power & Cooling Considerations Costs Making the Choice 2 History
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200
Enterprise Data Centres
Enterprise Data Centres 09/12/2014 MAR0064 Cannon Data Campus s Pre-Engineered, factory built modules and systems combine to produce a high performance, efficient, Data Centre Campus. s White Space, Mechanical
NIGERIA S PREMIUM DATA CENTRE
NIGERIA S PREMIUM DATA CENTRE TIER III DESIGN CERTIFIED SECURE RELIABLE SCALABLE 1 WHY WOULD YOU WANT TO BUILD A DATA CENTRE? IT TAKES MILLIONS OF US DOLLARS TO BUILD AN EFFICIENT DATA CENTRE. A KEY ASSET,
CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.
CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY. ABOUT CYRUSONE GLOBAL DATA CENTER FACILITIES. A Global Leader 24 high performance data centers worldwide Servicing 9 of top 20 Global Fortune
IBM Portable Modular Data Center Overview for Critical Facilities Round Table
Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation Key messages Containers
Common mistakes in datacentre planning
Common mistakes in datacentre planning White Paper Last edited: March 2013 Document Control Document Information Title Author Common mistakes in datacentre planning Nick Ewing This document is based upon
Building a data center. C R Srinivasan Tata Communications
Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its
Managing Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
THE WORLD S MOST EFFICIENT DATA CENTER
THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject
High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.
High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white
Juniper Networks QFabric: Scaling for the Modern Data Center
Juniper Networks QFabric: Scaling for the Modern Data Center Executive Summary The modern data center has undergone a series of changes that have significantly impacted business operations. Applications
Microsoft Technology Center: Philadelphia
A Customer Success from the Experts in Business-Critical Continuity TM. Background Microsoft Technology Center: Philadelphia Microsoft Technology Centers are collaborative, state-of-the-art facilities
Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design
Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre
Data Center Power Consumption
Data Center Power Consumption A new look at a growing problem Fact - Data center power density up 10x in the last 10 years 2.1 kw/rack (1992); 14 kw/rack (2007) Racks are not fully populated due to power/cooling
Greening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
Energy Efficiency and Availability Management in Consolidated Data Centers
Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal
Uptime Institute Annual Report: Data Center Density
U P T I M E I N S T I T U T E, L L C Uptime Institute Annual Report: Data Center Density By Vince Renaud, PE and Matthew Mescall, CFM Copyright 2011 by Uptime Institute, LLC 20 West 37th Street 6th Floor
Elliptical Mobile Solutions Data Center Solutions
Elliptical Mobile Solutions Data Center Solutions The Next Genera-on of Modular Data Centers Copyright Ellip.cal Mobile Solu.ons 2010 www.ellip.calmobilesolu.ons.com 1 EMS CURRENT PRODUCTS BENEFITS We
Greener Pastures for Your Data Center
W H I T E P A P E R Greener Pastures for Your Data Center 2 Executive Summary Following a green path, once a concept relegated to a small group of environmentalists and the U.S. Environmental Protection
Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE. Industry leading data center solutions for HPC, Cloud and Enterprise markets.
Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE Industry leading data center solutions for HPC, Cloud and Enterprise markets. Leadership, Collaboration & Expertise CooIIT Systems Innovates and Delivers
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
Essential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING
LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING Summary Experts estimate that the average design life of a data center is 10-15 years. During that time, equipment
Huawei Data Center Facility Integration Solution
Huawei Data Center Facility Integration Solution HUAWEI TECHNOLOGIES CO., LTD. As the growing demand for efficiency, flexibility and low-cost, enterprise need a more flexible and efficient data center
SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity
SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One
A Simple Model for Determining True Total Cost of Ownership for Data Centers
W h i t e P a p e r A Simple Model for Determining True Total Cost of Ownership for Data Centers By Jonathan Koomey, Ph.D. with Kenneth Brill, Pitt Turner, John Stanley, and Bruce Taylor (Editor s Note:
Determining Total Cost of Ownership for Data Center and Network Room Infrastructure
Determining Total Cost of Ownership for Data Center and Network Room Infrastructure White Paper #6 Revision 3 Executive Summary An improved method for measuring Total Cost of Ownership of data center and
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
The Pros and Cons of Modular Systems
The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated
Data Centre Outsourcing a Buyer s Guide
Data Centre Outsourcing a Buyer s Guide The inside guide to deciding whether to outsource your data centre facility and operations and how to select an appropriate partner. This Guide will help you Determine
Measuring Energy Efficiency in a Data Center
The goals of the greening of the Data Center are to minimize energy consumption and reduce the emission of green house gases (carbon footprint) while maximizing IT performance. Energy efficiency metrics
Advania Cloud Co-location
Advania Cloud Co-location Advania Cloud Co-location Advania data center offers an attractive hosting option for companies in Europe and the US that are looking for high quality, low cost and environmentally
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use
Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services
Data Center & IT Infrastructure Optimization Trends & Best Practices Mickey Iqbal - IBM Distinguished Engineer IBM Global Technology Services IT Organizations are Challenged by a Set of Operational Issues
Data Center Solutions - The Containerized Evolution
Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1 We are the global specialist
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE. By Christian L. Belady, P.E.
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE By Christian L. Belady, P.E. GLOBAL FOUNDATION SERVICES MARCH 2011 Author s Note: this work is intended to be an exercise to estimate the size
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
FEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
EXECUTIVE REPORT. Scalability & Capacity Planning: Build vs. Buy
EXECUTIVE REPORT Scalability & Capacity Overview This paper explores issues that arise when planning for growth of Information Technology infrastructure. The paper explains how colocation of data centers
Re-examining the Suitability of the Raised Floor for Data Center Applications
Re-examining the Suitability of the Raised Floor for Data Center Applications By Neil Rasmussen White Paper #19 Revision 1 Executive Summary The circumstances that gave rise to the development and use
Is an energy-wasting data center draining your bottom line?
Abstract Is an energy-wasting data center draining your bottom line? New technology options and power distribution strategies can dramatically reduce the cost and carbon footprint of your data center.
Protecting Our Information, Protecting Our Resources
Solutions For Business-Critical Continuity Protecting Our Information, Protecting Our Resources Energy Efficient Power And Cooling For IT And Telecommunications Network Infrastructures The Challenge You
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
Reducing Data Center Energy Consumption
Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate
Best Practices in Business Recovery: Colocation or DRaaS? By Brien M. Posey
Best Practices in Business Recovery: Colocation or DRaaS? By Brien M. Posey axcient.com 1 Introduction In the not-too-distant past, protecting an organization s data meant shipping backup tapes offsite
IBM Twin Data Center Complex Ehningen Peter John IBM BS [email protected]. 2011 IBM Corporation
IBM Twin Data Center Complex Ehningen Peter John IBM BS [email protected] Overview Profile IBM owned facility 6447 m² IT-Space Infrastructure concurrent maintainable (Tier Level 3) Feed-ins of Power
Specialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
Premium Data Centre Europe - 2012 Pricing, Business Model & Services
Premium Data Centre Europe - 2012 Pricing, Business Models & Services Premium Data Centre Europe - 2012 Pricing, Business Model & Services Table of Contents A list of figures used in this report 5 Methodology
EXECUTIVE REPORT. 4 Critical Steps Financial Firms Must Take for IT Uptime, Security, and Connectivity
EXECUTIVE REPORT 4 Critical Steps Financial Firms Must Take for IT Uptime, Security, and Connectivity When Millions of Dollars of Financial Transactions are On the Line, Downtime is Not an Option The many
The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric
Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000
Top 5 Trends in Data Center Energy Efficiency
Top 5 Trends in Data Center Energy Efficiency By Todd Boucher, Principal Leading Edge Design Group 603.632.4507 @ledesigngroup Copyright 2012 Leading Edge Design Group www.ledesigngroup.com 1 In 2007,
DATA CENTERS BEST IN CLASS
Data Energy Audit Chameleon Data Center DATA CENTERS BEST IN CLASS... By Wouter Kok, MSc, Strategic Advisor Global Data Center Practice Deerns leads the way in making data centers greener, by reducing
Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009
Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of
Data Center Colocation Build vs. Buy
Data Center Colocation Build vs. Buy Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for
AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WH I TE PAPE R AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies,
Jan Kremer s Data Center Design Consultancy
Jan Kremer s Data Center Design Consultancy Datacenter Design Jan Kremer has designed a Tier Level 3 Datacenter for one of the main banks in Saudi Arabia This included Floor Plans, Power Requirements,
SMART SHELTER CONTAINER
Da ta Ce nt er Total Flexibility and Security in a Modular Data Center Advantages Environmentally Friendly Short Delivery Time Smart Shelter Container (SSC) solution provides a fully functional Data Center