A-Series Data Loggers PRODUCT MANUAL



Similar documents
1000 Series Data Loggers PRODUCT MANUAL

Spectrum Technologies, Inc.

Data-Logging Rain Gauge PRODUCT MANUAL

Soil Sensor Reader PRODUCT MANUAL

Data Analysis Software

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

MTX-D, Oil Temperature/Pressure Gauge

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

PL-1, Pocket Logger B

VM-4 USB Desktop Audio Device Installation Guide

WindLog User s Guide

Laser Wireless Rechargeable Mouse. User s Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

VM-8 USB Desktop Audio Device Installation Guide

User Manual. Humidity-Temperature Chart Recorder. Model RH520

How To Install A Power Supply (Uplast) With A Battery Pack

Quick Start Guide RRL Radio Telemetry

NortechCommander Software Operating Manual MAN R6

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide WIRELESS SCANNER

Getting started with

DMX USB PRO. User Manual.

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Powerware Relay-Serial Card User s Guide

2 TM. Users Manual. SEC100, SEC200 USB Media Alert

LP 2844 Thermal Printer

Ash Capture Control User Guide

About Your NetBotz 4-20mA Sensor Pod

How To Use An Imclean Dad (Dvd) With A Car Or Car (Dcd) On A Computer Or Car

USER MANUAL DUET EXECUTIVE USB DESKTOP SPEAKERPHONE

Keep it Simple Timing

Optical Wireless Mouse. User s Manual

Transferring Scans from your Dolphin into Destiny

LandAirSea Tracking Key READ THIS BEFORE USING THE LANDAIRSEA TRACKING KEY

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

User s Manual C R Y S T A L. engineering corporation

Regulatory Compliance. IC Certification. FCC Certification. Declaration of Conformity

GX-2009 Data Logger Management Program Operator s Manual

RIGtalk. Revision 5. Owner s Manual 2012.

SpecWare Professional. Advanced Features User s Guide

Crow Limited Warranty. Print Version 017

1 Mounting and Sensor Installation

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

BMV-602 Data Link Manual

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

LabelWriter. Print Server. User Guide

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

2008 Davis Instruments Corp. All rights reserved. Information in this document is subject to change without notice.

Global Water Instrumentation, Inc.

MTX-D, Boost/Shift Gauge

USB Scrolling Optical Mini Mouse

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

New MINIMAG Magnetic Stripe Reader

USB INTERFACE BELL202 MODEM MODEL: COP-HU DRIVER INSTALLATION MANUAL

Running the R4 Software on a USB Port

LDG DTS-4/4R Desktop Coaxial Switch / Remote

AUDITVIEW USER INSTRUCTIONS

iminiplus PDF User Guide Version 2.0

Amcrest 960H DVR Quick Start Guide

Signal Manager Installation and Operation Manual

Tracking Key II User s Guide.

DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth

HOBO U14 Data Logger User Manual

User Guide. Temperature and Humidity Datalogger. Model 42280

Quick Start Guide. Control & Display Guide. Direction to Location Battery Level Indicator. Local Time. Satellite Locked Icon MARK Button.

Quick Start Guide. Internet Conference Station X1-N6.


Installing Global Logger USB Drivers

DCX300 - DCX400 - DCX600

Downloading Images and Movies from a Digital Camera to OLYMPUS Master 2

TS-300-MSF TS-300 INSTALLATION AND CONFIGURATION MANUAL

Global Water Instrumentation, Inc.

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302

Power Log PC Application Software

Road Sensor Control Software for Retroreflectometer LTL - XL

User Manual. Product Model: MiTraveler 7D-4A. OS: Android 4.0

USB Guide Port Adapter User Manual Model GPUSB

Brady IP Printer Installation Instructions

AUDITVIEW USER INSTRUCTIONS

SpecWare 9 Pro and Basic Software PRODUCT MANUAL

78 Battery Converter HDMI to SDI

MACTek Corporation. USB HART Interface. Users Manual

Sip/Puff Switch User Guide

RACEAIR REMOTE PAGER SYSTEM

3800 Linear Series. Quick Start Guide

Wireless Mouse USER GUIDE. for Mac. ONE YEAR LIMITED WARRANTY N2953

MS830 / MS833 Barcode Reader v1.0 9-December-2014

User s Manual. Bluetooth Calculator Keypad. Page

Two-wire interface suitable for measuring mechanical and electrical contact closures Maximum input frequency 1 Hz (1 pulse per second)

USER MANUAL MOBILE HARD DRIVES DESKTOP HARD DRIVES. Rev. 034/Mac

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC

Data Entry Foot Switch Operation Manual

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

User Manual. Product Model: MiTraveler 10C3. OS: Android 4.0

Transcription:

A-Series Data Loggers PRODUCT MANUAL Model # s A110, A125, A130, and A150

Contents Model Specifications 2 Connecting to the Computer 3 SpecWare Software 4 Installation and Placement 6 Battery Replacement 7 Trouble Shooting 7 Warranty 8 Model # Internal Sensors External Sensors Measurement Capacity A110 Temp None 8,000 data points A125 Temp Temp 8,000 data points (4,000 per sensor) A130 Temp Leaf Wetness 8,000 data points (4,000 per channel) A150 Temp/RH None 10,666 data points (5,333 per channel) Temperature Range: -40 to 185 F (-40 to 70 C) Accuracy: ±1.1 F from -4 to 122 F (±0.6 C from -20 to 50 C), else ±2.2 F (±1.2 C ) RH Range: 0 to 100% Accuracy: ±3% from 10 to 90% at 77 F (25 C), else ±5% Leaf Wetness Range: 0 to 15 For customer support, or to place an order, call Spectrum Technologies at (800)248-8873 or (815)436-4440 between 7:30 am and 5:30 p.m. CST, FAX at (815)436-4460, or E-mail at info@specmeters.com. Spectrum Technologies, Inc 12360 S Industrial Dr. East Plainfield, IL 60585 www.specmeters.com 2

Thank you for purchasing a WatchDog A-Series Data Logger. This manual describes how to use your WatchDog Logger and keep it working accurately for many years. Read this manual thoroughly in order to get effective performance from your data logger. IMPORTANT NOTE FOR THE A125 and A130: The A125 and A130 logger models use the same physical logger. The logger is designed to read temperature as the external sensor. For the A130 logger, the Leaf Wetness sensor value is saved in the logger as a temperature, and is then translated back to a leaf wetness value by SpecWare. Connecting to the Computer The A-Series loggers do not use the standard gray PC interface cable that accompanies SpecWare Software. Instead, you need the A-Series PC Connection Cable (Item 3661A). The cable is a serial USB cable and requires that you install the driver prior to its use. The driver is included on the SpecWare Software installation CD for SpecWare 9 Pro or Basic, Version 9.01 Build 206 or greater, as well as on the SpecWare 9 update page at www.specmeters.com. After installing the drivers, if you plug in the cable before you start SpecWare (or leave it plugged in), SpecWare will automatically find the COM port used by the cable. The 2.5mm stereo pin connects to the jack labeled Com on the data logger. The jack labeled Ext is reserved for an external sensor (if applicable). The only time you must have the WatchDog connected to the computer is during the launching and downloading of the data logger. After the logger has been launched, and/or downloaded, disconnect the logger and place it in the environment you wish to monitor. 3

SpecWare Software SpecWare software version 9.01, Builds 206 and above support the WatchDog A-Series loggers, except the A130, which requires version 9.02. Previous builds of SpecWare 9 can be updated via the free downloads available at www.specmeters.com. The software version can be checked by selecting About SpecWare from the Help menu. Complete details on the software are included in the SpecWare Software manual which is available as a pdf document on the installation CD (and accessible via the Help menu). The following sections summarize the most commonly used functions. Initializing the Serial Number and Logger Type The first time that an A-Series logger is read by SpecWare, an initialization screen will open. Enter the serial number printed on the back of the logger. Logger Models A125 and A130 are physically the same. The Model A130 must be electronically marked so SpecWare knows to translate its external sensor signals to a leaf wetness value. For the A125 and A130, please select the corresponding model number before clicking the Initialize button. The screen remains open so you can initialize several new loggers as a batch. Logger Location Names SpecWare maintains a list of A-Series logger serial numbers and their corresponding location names. As a result, the first time an A-Series logger is connected on a PC, SpecWare will ask for a location name. If you are planning to launch loggers with one PC and read them with another, you may wish to use the default name of model-number-serialnumber to make tracking easier. 4

Launching Loggers The launch screen is used to configure the logger and activate it so it can collect data. The launch screen can be accessed by selecting the Launch WatchDog A-Series option from the Logger menu or clicking the icon on the SpecWare toolbar. Select the logging interval (ranging from 1 to 120 minutes), and ensure all channels are enabled before clicking Ok to launch the logger. You may also choose to Delay the start of logging to a later time. Downloading The Loggers The download sequence is initiated by selecting the Get WatchDog A- Series data option from the Logger menu or by clicking the icon on the SpecWare toolbar. When the download is complete, the data will be saved in the location defined for that logger. Charts/Reports Whenever a file is opened, SpecWare will automatically generate a chart. You will be given the choice of which parameters are to be plotted. The Tools menu gives you access to a variety of standard and user-defined (SpecWare Pro only) reports. 5

Installation and Placement WatchDog loggers have the versatility to be located in any micro-climate for recording weather data. The sensors and the mini-radiation shield include hardware for attaching them on a 1 to 1¼ outside diameter mast (pipe). Use a 5-10 length of conduit or pipe as the mast mount. When purchasing and/or cutting the mast to size, plan on placing 1½ - 2 of the mast into the ground. For outdoor and greenhouse use, the logger should be placed in a 3663A Radiation Shield to protect it from solar radiation and other sources of reflected heat. The radiation shield also protects the A125 and A130 loggers from rain. To place the WatchDog into the radiation shield, unscrew the two finger-nuts and remove the top of the radiation shield. Important: External sensor wires connect to the logger from the side at the point where the top and bottom sections meet. Secure the external sensor wires to the mast just below the radiation shield with a plastic tie to ensure that the sensor wires do not become disconnected while recording. 6 Radiation Shield

Battery Replacement Each WatchDog A-Series Data Logger is powered by a 3 volt Lithium CR2 battery. The battery has a life of over 12 months continuous use. It is user replaceable and can be purchased locally, as it is commonly used in photographic equipment. To replace the battery: 1. Remove the four screws on the back, then the cover. 2. Replace the battery, ensuring it is oriented so that the +/- marks on the battery match those on the inside of the battery location. 3. Replace the cover and the screws. Trouble Shooting Q. Why won t the logger connect with the computer? A. The logger may need a new battery or the COM Port settings may need to be changed through SpecWare software. You also may have the cable plugged into the Ext (sensor) port instead of the Com port. Q. Why is the A125 or A130 logging invalid or out-of-range values? A. The A-Series loggers require special models of the external temperature and leaf wetness sensors. If the sensors designed for other WatchDog models are used, or if the external sensor is not plugged in, the logger will not read properly. Also, the Model A130 logger requires SpecWare 9.02. Using an earlier version will result in invalid data. Q. Can I use the external port of my WatchDog Model A125 or A130 to monitor rainfall or other sensors? A. No. The external port is only set up to be connected to a temperature sensor (for the A125) or a leaf wetness sensor (for the A130). 7

Warranty This product is warranted to be free from defects in material or workmanship for one year from the date of purchase. During the warranty period Spectrum will, at its option, either repair or replace products that prove to be defective. This warranty does not cover damage due to improper installation or use, lightning, negligence, accident, or unauthorized modifications, or to incidental or consequential damages beyond the Spectrum product. Before returning a failed unit, you must obtain a Returned Materials Authorization (RMA) from Spectrum. Spectrum is not responsible for any package that is returned without a valid RMA number or for the loss of the package by any shipping company. This equipment has been manufactured for Spectrum Technologies, Inc. 12360 S. Industrial Dr. East Plainfield, IL 60585 USA The Manufacturer s DECLARATION OF CONFORMITY is on file at the above address, and certifies conformity to the following: Model Number: A110, A125, A130, A150 Description: WatchDog A-Series Data Loggers Type: Electrical Equipment for Measurement, Control, and Laboratory Use Directive: 2004/108/EC Standards: EN 61326-1 (2006) CISPR11 EN 61000-4-2 (1995/A1:1998/A2:2001) EN 61000-4-3 (2006) 8 12360 S. Industrial Dr. E Plainfield IL 60585 (800) 248-8873 or (815) 436-4440 Fax (815) 436-4460 E-Mail: info@specmeters.com www.specmeters.com Rev. 03/29/2010