1 TRAKPRO Data Analysis Software User s Manual November 1996 P/N Rev. D TSI Incorporated

2

3 TRAKPRO Data Analysis Software User s Manual November 1996 P/N Rev. D SHIP TO: TSI Incorporated 500 Cardigan Road Shoreview, MN USA U.S. Sales & Customer Service: (800) /(612) Fax: (612) MAIL TO: TSI Incorporated P.O. Box St. Paul, MN USA INTERNATIONAL Sales & Customer Service: ( ) Fax: ( )

4 Copyright TSI Incorporated/May 1996/All rights reserved. Address TSI Incorporated/P.O. Box 64394/St. Paul, MN 55164/USA Fax No. (612) LIMITATION OF WARRANTY AND LIABILITY Seller warrants that this product, under normal use and service as described in the operator's manual, shall be free from defects in workmanship and material for a period of twelve (12) months, or the length of time specified in operator's manual, from the date of shipment to the customer. This limited warranty is subject to the following exclusions: a. Batteries, hot wire or hot film sensors and certain other components when indicated in specifications are warranted for a period of 90 days from the date of shipment to the customer. b. With respect to any repair services rendered, Seller warrants that the parts repaired or replaced will be free from defects in workmanship and material, under normal use, for a period of 90 days from the date of shipment to the customer. c. Seller does not provide any warranty on finished goods manufactured by others. Only the original manufacturer's warranty applies. d. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, any goods which are incorporated into other products or equipment by the Buyer. All goods returned under warranty shall be at the Buyer s risk of loss, Seller s factory prepaid, and will be returned at Seller s risk of loss, Buyer s factory prepaid. The foregoing is IN LIEU OF all other warranties and is subject to the conditions and LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. THE EXCLUSIVE REMEDY OF THE USER OR PURCHASER, AND THE LIMIT OF THE LIABILITY OF SELLER FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES IN CONNECTION WITH THIS PRODUCT (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT, OR OTHERWISE) SHALL BE THE RETURN OF THE PRODUCT TO THE FACTORY OR DESIGNATED LOCATION AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING, REASSEMBLY OR REINSTALLATION COSTS OR CHARGES. NO ACTION, REGARDLESS OF FORM, MAY BE BROUGHT AGAINST THE SELLER MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS ACCRUED. The purchaser and all users are deemed to have accepted the terms of this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended or modified nor may any of its terms be waived except by a writing signed by an authorized representative of Seller. U.S. GOVERNMENT RESTRICTED RIGHTS. The SOFTWARE and documentation are provided with RESTRICTED RIGHTS. Use, duplications, or disclosure by the Government is subject to the restrictions set forth in the Rights in Technical Data and Computer Software clause at and the Commercial Computer Software Restricted Rights clause at Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call TSI's Customer Service department at (888) (USA) or ( ) (International).

5 CONTENTS About this Manual...iii 1. OVERVIEW...1 Introduction...1 Programming a Logging Instrument...1 Receiving and Managing Test Data...2 Graphing Test Data...2 Printing Reports GETTING STARTED...5 Introduction...5 Installing TRAKPRO...5 Minimum Hardware Requirements...5 Minimum Software Requirements...5 Installation Procedure...5 Starting and Ending TRAKPRO...6 Using the TRAKPRO Main Window...6 Using Menu Options...7 Using Toolbar Buttons...8 Connecting the Logger to the Computer...8 Setting Up the Logger Communications Port USING LOGGER SETUP OPTIONS...11 Introduction...11 Viewing Supported Logger Models...11 Setting Up the Communications Port...12 Programming the Available Logging Intervals...13 Programming the Available Time Constants...14 Programming the Logger Date and Time...15 Programming Advanced Logging Modes...15 Sample Protocol for LOG 2 and LOG 3 Modes MANAGING DATA FILES...21 Introduction...21 Receiving Test Data...21 Updating Test Information...23 Viewing Test Data...23 Saving Test Data...25 Importing Data...26 Exporting Data...27 i

6 5. WORKING WITH GRAPHS...29 Introduction...29 Creating a Graph...29 Using Graph Toolbar Buttons...32 Closing the Current Graph Display...32 Using Zoom...32 Making Notes on a Graph...33 Viewing Graph Statistics...33 Using Graph Menu Options...34 Opening an Existing Graph...34 Changing the Graph Type...35 Changing the Graph Title...35 Changing the Graph Channels...36 Changing the Graph Y-Axis...37 Changing the Graph X-Axis...38 Specifying Graph Legends and Markers...38 Deleting Graph Notes...40 Changing Graph Colors...40 Saving a Graph...41 Deleting a Graph...41 Sample 1: Single-Channel Graph...42 Sample 2: Single-Channel Graph with Overlayed Channels...42 Sample 3: Multi-Channel Graph with Overlayed Channels...43 Sample 4: Multi-Channel Graph with Log Scaling PRINTING...45 Introduction...45 Printing Graph Reports...45 Printing the Current Graph...46 Printing Test Data...47 Printing Test Statistics...47 Setting Up the Printer...48 Printing Options...48 ii

7 About this Manual INTRODUCTION This manual explains how to install, set up, and use the TRAKPRO Data Analysis Software version TRAKPRO is intended for use with a variety of TSI data logging instruments. (To see a list of supported logging instruments, refer to Viewing Supported Logger Models in chapter 3 of this manual.) Organization This manual is organized as follows: Chapter Description 1 Gives an overview of TRAKPRO functions and features. 2 Gives step-by-step instructions for installing TRAKPRO and describes how to get started using the software. 3 Describes how to set logger options to customize tests. 4 Describes basic data file management. 5 Describes how to create and modify graphs. 6 Describes how to print reports. Conventions The following conventions are used throughout this manual: Convention boldface Underline Description Menu options are shown in boldface type. Menu items can be selected with the mouse or by pressing the A key and the shortcut key for the menu or option. The shortcut key is underlined both on the screen and in this manual. For example, to select the File menu, you can press A F. Related Publications While using this manual, you may also need to refer to the following related publications: TRAKPRO is a Windows-based software product. For complete information on using Windows, refer to your Windows documentation. iii

8 TRAKPRO can be used with a variety of TSI data logging instruments. For complete information on the specific instrument you are using, refer to the reference manual that accompanies your data logging instrument. Trademarks Microsoft, MS, MS-DOS and Windows are registered trademarks of Microsoft Corporation. TRAKPRO is a trademark of TSI Incorporated. iv

9 Chapter 1 Overview Introduction TRAKPRO is a Windows-based application that works with a variety of TSI data logging instruments. This chapter briefly presents the tasks you can perform using TRAKPRO: Programming a logging instrument. Receiving and managing test data. Graphing test data. Printing reports. For detailed information on your logging instrument, refer to the manual that accompanies the instrument. Programming a Logging Instrument TRAKPRO provides options that allow you to program the following logging instrument parameters: Menu of available logging intervals. The logging interval used in LOG 1 mode must be selected from a list of five preprogrammed values. This list can be reprogrammed using TRAKPRO. Menu of available time constants. The instrument time constant must be selected form a list of five preprogrammed values. This list can be reprogrammed using TRAKPRO. Logger date and time. TRAKPRO allows you to program the date and time value stored in the logging instrument. LOG 2 and LOG 3 Modes. The logging instrument has three different logging modes: LOG 1 mode, LOG 2 mode and LOG 3 mode. LOG 1 mode is a manual mode where the instrument logs all channels and sampling must be manually started and stopped. LOG 2 and LOG 3 modes can be customized and set up for unattended sampling. 1

10 Receiving and Managing Test Data Once a test sample has been stored in the logger instrument memory, you can download the data to your computer using TRAKPRO. All test data is automatically identified by the following: Model number of the logger. Serial number of the logger. Time and date of the test. Channels logged. Unique test ID number for each test. Once you have downloaded a test, TRAKPRO allows you to further identify each test by providing the following: A short abbreviation that can be used to identify data on graphs. A summary that describes the test. Multiple tests can be stored in one file, and you can add tests to an existing file. Graphing Test Data TRAKPRO graphing options allow you to quickly analyze test samples. Graph options include: Single- and multi-channel graphs. A single-channel graph allows you to simultaneously display from one to six tests of the same type (channel). For example, you can display the CO 2 channel from multiple tests on the same graph. With a multi-channel graph, you can simultaneously display any combination of up to six channels from any single test in the file. For both single- and multi-channel graphs, you can display the channels in real time or overlay the channels for comparison. Linear and log graphs. By default, TRAKPRO calculates the y-axis values that best display each channel on a linear graph. For data that may vary by orders of magnitude, you can display the data in a log graph. Automatic and manual scaling. By default, graph data is displayed using automatic scaling. That is, the high and low values along the y-axis are automatically calculated. When you select manual scaling, you can enter the high and low values. 2 Chapter 1

11 Legends and markers. By default, each of the possible six channels in a graph are identified by a unique color. You can also identify each channel with a legend either a pre-defined legend or a user-defined legend. For non-color displays and printers, TRAKPRO can also use a unique marker for each channel to distinguish one channel from another. You can choose to display or not display the markers. Printing Reports With the TRAKPRO report-generating feature, you can print test data and statistics. You can also customize printed reports for graphs and associated graph data. Once you download or open a data file, the print options include: Current graph. You can print the graph currently displayed on the screen. Test data. You can print the test data, which includes the values for each logged data point for all channels in the test, along with the date and time at which each occurred. Test statistics. For each channel in the test, you can print the average, minimum, and maximum values, as well as the date and time at which the minimum and maximum values occurred. Once you create or open a graph, the print report option includes: Graph. You can print the current view of the graph. Graph data. For each channel on the graph, you can print the associated data. The data includes the date, time, and value for each logged data point. Graph statistics. For each channel on the graph, you can print a summary of the statistics. The statistics include the average, lowest, and highest logged data points, along with the date and time at which the lowest and highest points occurred. Overview 3

12 Test summary. For each channel on the graph, you can print the test summary associated with that channel. Calibration data. For each channel on the graph, you can print the date and time of the last calibration. You can also define a header to be printed on each page of the report, as well as specifying the orientation portrait or landscape for the graph. 4 Chapter 1

13 Chapter 2 Getting Started Introduction This chapter describes the following: Installing TRAKPRO. Starting and ending TRAKPRO. Using the TRAKPRO main window. Using menu options. Using toolbar buttons. Connecting the logger to your computer. Setting up the logger communications port. Installing TRAKPRO To install TRAKPRO, you need the following: Minimum Hardware Requirements 386 PC 2 megabytes RAM VGA display hard disk drive floppy disk drive Minimum Software Requirements MS-DOS 3.01 (or higher) MS Windows 3.0 (or higher) TRAKPRO release diskette. (TRAKPRO is released on a 3 1/2-inch diskette. If necessary, call TSI for a free 5 1/4-inch release diskette.) Installation Procedure To install TRAKPRO: 1. Insert the release diskette into an available drive. 2. At the DOS prompt, enter the letter of the drive that contains the release diskette and the install command. For example, if the release diskette is in drive A:, enter: a:install R 3. Select drive. 4. Select directory. The install program will automatically create a program group and TRAKPRO icon. 5

14 Starting and Ending TRAKPRO To start TRAKPRO: 1. Select the TSI products group icon. 2. Select the TRAKPRO application icon. The TRAKPRO main window is displayed. OR 1. Change to the directory in which TRAKPRO is installed. 2. Enter the following at the DOS prompt: win trakpro R To end TRAKPRO: Select Exit from the File menu. Using the TRAKPRO Main Window The following figure shows the TRAKPRO main window: The numbered areas of the main window are described below: 1 Main menu bar. 2 Toolbar. 3 List of tests in the current data file. The highlighted test is the current test. To make a test the current test, move the highlight to the test you want to select using either the mouse or the arrow keys. 6 Chapter 2

15 4 Displays information about the current test. You can change the Abbreviation and Summary information at any time by entering new text and selecting the Update button. 5 Displays the channels logged for the current test. 6 Updates information for the current test. Using Menu Options The TRAKPRO main window provides the pull-down menus described in the following table. You can select a menu option using either the mouse or the keyboard: To select an item using the mouse, move the cursor to the menu and click the left mouse button. Then, click on the menu option you want to select. To select an item using the keyboard, press the A key and the underlined letter of the menu you want to select. For example, to select the File menu, press A F. Then, to select an option from the menu, press the underlined letter for the option. Menu File Graph View Print Logger Setup Help Description Allows you to receive test data from the logger, as well as open, save, import data files and export data to a comma-delimited ASCII file. Allows you to create and modify graphs. Allows you to view information on test data, as well as graphs and graph statistics. Allows you to print graphs, test data, test statistics, and/or reports including all or a selection of graph report options. Allows you to set logger options, such as logging intervals, time constants, logger date and time, as well as advanced logging mode options. Displays help information. Getting Started 7

16 Using Toolbar Buttons In addition to the pull-down menus, the TRAKPRO main window offers the following toolbar buttons. Toolbar buttons offer quick access to commonly used menu options. Button Description Opens a data file. Saves the current data file. Receives tests from the logging device. Displays the current graph. Displays the current test statistics. Displays the current test data. Prints reports. Displays help information. Connecting the Logger to the Computer Each logging instrument comes equipped with an RS-232 cable and a 25-pin to 9-pin serial cable adapter. One end of the cable is a 25-pin D subminiature connector labeled COMPUTER; the other end is an RJ-45 modular connector that mates with the logging instrument. Serial port connectors always have pins (male) on the computer side. 1. Locate an available serial port on your computer: COM1, COM2, COM3, or COM4. 2. If the port has a 25-pin connector, you do not need the adapter. If the port has a 9-pin connector, plug the 25-pin end of the adapter into the RS-232 cable. 3. Connect the RS-232 cable to the available serial port on your computer. 4. Connect the RJ-45 connector to the logging instrument. Setting Up the Logger Communications Port 1. If you have not already done so, start TRAKPRO. 2. Turn on the logging device. 8 Chapter 2

17 3. Select Communications Port from the Logger Setup menu. The following dialog is displayed: 4. Enter the following: Serial Port Baud Rate Select the name of the serial port to which the logging device is connected: COM1, COM2, COM3, or COM4. Select the baud rate for the port. Higher baud rates are recommended to transfer data at a faster rate. Select a lower baud rate only if you are having trouble communicating at a higher rate. 5. Select Test to verify that you have set up the communications port properly. The system displays an informative message indicating whether it was able to establish communications. 6. Select OK to accept the setup or Cancel to discard the changes. Note: Some computers do not communicate reliably at baud rates above Getting Started 9

18

19 Chapter 3 Using Logger Setup Options Introduction This chapter describes the options available on the Logger Setup menu: Viewing supported logger models. Setting up the communications port. Programming the available logging intervals. Programming the available the time constants. Programming the logger date and time. Programming advanced logging modes. The end of this chapter provides a sample protocol for LOG 2 and LOG 3 modes. Viewing Supported Logger Models To view a list of logging instruments supported by TRAKPRO: 1. Select Model from the Logger Setup menu. The following dialog is an example of what might be displayed: 2. Select the logging instrument for which you want more information. The following dialog is an example of what is displayed when selecting the Q-TRAK with CO button. 11

20 3. The Setup button located under some instruments allows you to perform an instrument setup for that device. 4. Select Close to return to the Logger Model dialog. Then select Close to return to the main window. Setting Up the Communications Port To set up the communications port for the currently selected logger model: 1. If you have not already done so, connect the logging device to your computer. Refer to Connecting the Logger to your Computer in chapter Turn on the logging device and start TRAKPRO. 3. Select Communications Port from the Logger Setup menu. The following dialog is displayed: 12 Chapter 3

21 4. Enter the following: Serial Port Baud Rate Select the name of the serial port to which the logging device is connected: COM1, COM2, COM3, or COM4. Select the baud rate for the port. Higher baud rates are recommended to transfer data at a faster rate. Select a lower baud rate only if you are having trouble communicating at a higher rate. 5. Select Test to verify that you have set up the communications port properly. The system displays an informative message indicating whether it was able to establish communications. 6. Select OK to accept the setup or Cancel to discard the changes. Note: Some computers do not communicate reliably at baud rates above Programming the Available Logging Intervals To program the list of logging intervals available for LOG 1 mode: 1. Make sure the logging instrument is connected to the computer and turned on. 2. Select Logging Intervals from the Logger Setup menu. TRAKPRO retrieves the current logging intervals from the logging instrument and displays them in the following dialog: 3. Enter a value for each of the five available logging intervals. (The range you can enter is dependent on the logging instrument and is displayed on the Logging Intervals dialog box.) 4. Select Send. Using Logger Setup Options 13

22 The logging instrument is reprogrammed to offer the logging intervals you have specified. Note: For detailed information on logging intervals, refer to the manual that accompanies the logging instrument. Programming the Available Time Constants To program the list of time constants available from the logging instrument: 1. Make sure the logging instrument is connected to the computer and turned on. 2. Select Time Constants from the Logger Setup menu. TRAKPRO retrieves the current time constant settings from the logging instrument and displays them in the following dialog: 3. Enter a value for each of the five available time constants. (The range you can enter is dependent on the logging instrument and is displayed on the Time Constants dialog box.) 4. Select Send. The logging instrument is reprogrammed to offer the time constants you have specified. Note: For detailed information on time constants, refer to the manual that accompanies the logging instrument. 14 Chapter 3

23 Programming the Logger Date and Time To program the logger date and time: 1. Make sure the logging instrument is connected to the computer and turned on. 2. Select Set Logger Clock from the Logger Setup menu. TRAKPRO retrieves the current date and time settings from the logging instrument and displays them in the following dialog: 3. Enter a new date and time, and select Send. The logging instrument is reprogrammed with the date and time you specified. Programming Advanced Logging Modes To program a protocol for LOG 2 or LOG 3 mode: 1. Make sure the logging instrument is connected to the computer and turned on. 2. Select Advanced Logging Modes from the Logger Setup menu. TRAKPRO retrieves the current settings for LOG 2 and LOG 3 modes from the logging instrument and displays them in the following dialog: Using Logger Setup Options 15

24 The following table summarizes the information displayed in the Advanced Logging Modes dialog box: Logging Instrument Information Serial Number Displays the serial number of the logging instrument. Number of tests Displays the number of tests currently logged logged and stored in the logging instrument. Available Displays the percent of available memory in Memory (%) the logging instrument. 16 Chapter 3

25 LOG 2 and LOG 3 Mode Protocols Channels Displays the channels selected for sampling in LOG 2 and LOG 3 modes. Start Date Displays the start date for LOG 2 and LOG 3 modes. Start Time Displays the start time for LOG 2 and LOG 3 modes. Log interval Displays the log interval for LOG 2 and LOG 3 modes. Test length Displays the test length for LOG 2 and LOG 3 modes. Number of tests Displays the number of tests for LOG 2 and LOG 3 modes. Time between Displays the time between tests for LOG 2 tests and LOG 3 modes. Percent Displays the percent of logger memory memory required to perform a LOG 2 or a LOG 3 required. mode sample. To store the results of a LOG 2 or LOG 3 mode sample, the Available Memory must be equal to or greater than the Percent memory required. Using Logger Setup Options 17

26 3. Enter the following for LOG 2 and LOG 3 modes: Channels Start Date Start Time Log interval Test length Select the channels for which you want to log data. Enter the date and time to begin the sample: If you enter a blank for a start date, the sample begins whenever the specified start time occurs. If you enter a blank for the start time, both start date and start time are ignored, and the sample begins when the operator manually starts the sample. Enter the log interval to use for the test. For more information on log intervals and their relationship to memory used, refer to the manual that accompanies the logging instrument. Enter the length for the sample: If you enter a value, the instrument automatically turns off when the last test is complete. Number of tests Time between tests If you enter a blank, the operator must manually stop the sample. Enter the number of tests to perform. If you have specified more than one Number of tests, enter the time between tests. If you enter 0 or blank, the next test is started immediately after the last test is complete. 18 Chapter 3

27 While you are entering values for LOG 2 and LOG 3 modes, the Percent memory required is dynamically updated to show the amount of logger memory required to take the programmed sample. If the protocol you have defined requires more than 100% of memory, you can decrease the amount of memory required by manipulating the following protocol parameters: Decrease the number of channels for the sample. Increase the logging interval. Decrease the length for the test. Decrease the number of tests. The settings for each LOG mode must not require more than 100% of the logger memory. Note also that if the Percent memory required is greater than the Available memory, the logging instrument automatically stops the test when memory is full. 4. When you have finished defining the parameters for LOG 2 and LOG 3 modes, select Send. 5. You may now disconnect your logging instrument and cable from the computer. Refer to the Operation and Service Manual for your specific TSI logging instrument for details on making measurements using LOG 2 and LOG 3 modes. Sample Protocol for LOG 2 and LOG 3 Modes The following steps describe how to program a sample protocol for LOG 2 or LOG 3 mode. The sample protocol is set up to take unattended samples of C0 2 readings on five consecutive days beginning on 9/04/94. The logging sample begins at 6:00 a.m. each morning and stops at 4:00 p.m. each afternoon. 1. Make sure the logging instrument is connected to the computer and turned on. 2. Select Advanced Logging Modes from the Logger Setup menu. TRAKPRO retrieves the current settings for LOG 2 and LOG 3 modes from the logging instrument. Using Logger Setup Options 19

28 3. Enter the following for LOG 2 or LOG 3 mode: Channels CO 2, Temp, rh Start Date 05/09/96 Start Time 06:00 a.m. Log interval 05:00 Test length 00:10:00 Number of tests 5 Time between 00:14:00 tests Your screen should look similar to the following: 4. Select Send. The logging instrument is programmed for the mode 2 and mode 3 protocols. 5. You may now disconnect your logging instrument and cable from the computer. Refer to the Operation and Service Manual for your specific TSI logging instrument for details on making measurements using LOG 2 and LOG 3 modes. 20 Chapter 3

29 Chapter 4 Managing Data Files Introduction This chapter describes how to manage data test files. The following topics are covered: Receiving test data. Updating test information. Viewing test data. Saving test data. Importing data. Exporting data. Receiving Test Data To receive test data from a logging device: 1. If you have not already done so, connect the logging device to your computer, turn on the logger and start TRAKPRO. (For instructions on connecting the logger to your computer, refer to chapter 2, Getting Started.) 2. Select or Receive from the File menu. The following dialog is displayed: 21

30 The following table summarizes the information on the Receive Tests from Logger dialog: Model Serial Number Tests logged Percent memory left Model name of the logging instrument. Serial number of the logging instrument. Number of tests logged. Amount of memory currently available in the logging instrument. 3. Select the tests you want to receive and select Receive. TRAKPRO receives the test data from the logger and updates the TRAKPRO main window with the test information: 22 Chapter 4

31 The following table summarizes the information displayed in the main window: Tests Model Serial Number Abbreviation Channels Summary Lists the available tests. The current test is highlighted. Model of the instrument that logged the current test. Serial number of the instrument that logged the current test. An optional one- to ten-character description for the current test. Lists the channels logged for the current test. An optional description for the current test. The summary can be up to 200 characters. Updating Test Information You can update the abbreviation and summary information stored with a test: 1. Select the test for which you want to update information. 2. Enter the following: Abbreviation Enter an abbreviation for the test of up to ten characters. Summary Enter a summary for the test of up to 200 characters. 3. Select Update. Note: If you do not select Update, all changes are discarded when a new test is highlighted. Viewing Test Data Once you have received test data or opened an existing test data file, that file is the current data file. For each test in a data file, you can view test data and test statistics. To view test data: 1. Highlight the test in the main window for which you want to view data. Managing Data Files 23

32 2. Select or Test Data from the View menu. The following window is displayed: 3. Use the following buttons to scroll through the data. To select a button: Use the mouse to position the cursor to the button and click the left mouse button. Use the arrow keys to move the selection box (shown as dashedline box) to the button and press R. Close Start End down arrow up arrow Closes the display and returns you to the main window. Scrolls to the beginning of the data. Scrolls to the end of the data. Scrolls down one page. Scrolls up one page. To view test statistics: 1. Select the test for which you want to view statistics. 24 Chapter 4

33 2. Select or Test Statistics from the View menu. The following window is displayed: Channel Average Minimum Time Date Maximum Time Date Indicates the channels logged for the test. Indicates the average value for each channel. Indicates the minimum value the logging instrument displayed during the sample, along with the time and date at which the value occurred. * Indicates the maximum value the logging instrument displayed during the sample, along with the time and date at which the value occurred. * * The minimum and maximum values are not the lowest and highest logged data points, but rather the minimum and maximum values displayed on the logging instrument. 3. Select Close to close the display. Saving Test Data To save test data you have updated to the same file: Select or Save from the File menu. To save test data to a different file: Managing Data Files 25

34 1. Select Save As from the File menu. The following window is displayed: 2. Select the directory in which to save the file, and enter the file name. Data files are automatically assigned the file extension df1. 3. Select OK to save the test data. Importing Data You can merge test data from more than one file into one single file. To do so, use the Import option available on the File menu: 1. Select Import from the File menu. The following dialog is displayed: 26 Chapter 4

35 2. Select the file from which you want to import test data. The following window is displayed: 3. Select the tests you want to import into the current file, and select Import. If a data file is currently open, you are asked whether you want to import the tests into the current file. 4. Repeat steps 1 through 4 for each file that contains test data you want to merge together in one file. 5. Save the file using the Save As or Save command on the File menu. Exporting Data You can export some or all of the tests in any open data file to a commadelimited ASCII file. This exported file can then be loaded into a database or spreadsheet program for your own use. To export data, select Export from the File menu: 1 Select what test(s) you want to export and select Export. 2 The file dialog will appear. Enter the name of the file you want to export the data to or select one from the file list. The export process may take a few minutes for large data files. Managing Data Files 27

36

37 Chapter 5 Working with Graphs Introduction TRAKPRO allows you to create, modify, save, and print test data in graph form. This chapter describes the following: Creating a graph. Using graph toolbar buttons. Using graph menu options. The end of this chapter provides four sample graphs: Sample 1: Single-Channel Graph. Sample 2: Single-Channel Graph with Overlayed Channels. Sample 3: Multi-Channel Graph. Sample 4: Multi-Channel Graph with Log Scaling. Creating a Graph To create a graph: 1. If you have not already done so, open an existing data file or receive the test data from the logger and store it in a file. 2. Select New from the Graph menu. The following dialog is displayed: 29

38 3. Enter the following: Graph Name Main Title Sub title Channels displayed Type... Enter a unique name from one to twenty characters. Enter a title for the graph from zero to twentyfive characters. Enter a subtitle for the graph from zero to twenty-five characters. Select the channels you want to display on the graph. You can select from one to six channels. (The number of channels you select is displayed in the Total channels box.) Select Type and specify the graph type. To graph multiple types of channels (for example, CO 2, aerosol, and so on), select multi-channel. To graph different tests of a single channel type (for example, two or more CO 2 tests), select single-channel. After selecting the graph type, select OK. 4. Select OK. The graph you have defined becomes the current graph and is displayed on the screen. 30 Chapter 5

39 The following figure shows a sample multi-channel graph with automatic scaling: The following table summarizes the graph display areas. 4 1 Displays the name of the current graph. You can change the name by entering a new name in the box. 2 Displays the graph title and subtitle. 3 Displays the y-axis values for each of the displayed channels, starting with the first channel at the very left, the second channel next, and so on. 4 Displays x-axis values for the graph. 5 Displays the legend for the graph display. By default, channels are numbered from 1 to 6 and are shown in blue, light green, red, yellow, dark green, and purple. You can specify a different legend for the graph. You can also show markers on the graph for each channel. Refer to Specifying Graph Legends and Markers in this chapter. 5 Working with Graphs 31

40 Using Graph Toolbar Buttons While viewing a graph, the following toolbar buttons offer quick access to the graph menu options: Button Description Closes the graph display. Zooms in on the graph display. You can zoom in as many times as you want. Zooms out to the full graph display. Allows you to make notes on the graph. Displays graph statistics. Prints the current graph. Closing the Current Graph Display To close the current graph display: Select Close. Note: The graph does not automatically save when closed. See Saving a Graph in this section. Using Zoom To zoom in: 1. Select. A cursor is displayed. 2. Designate the area you want to enlarge: With the mouse, move the cursor to the upper left corner of the area you want to enlarge. Click and drag the box to define the area you want to enlarge. You can repeatedly zoom in on an area to further enlarge the view. Note: You can also define the area you want to view by changing the range in the x-axis dialog. Refer to Changing the X-Axis in this chapter. 32 Chapter 5

41 To return the display to the original size: Select. Making Notes on a Graph To make notes on a graph: 1. Select. 2. Move the cursor to the point in the graph at which you want to make a note, and click the left mouse button. 3. Type in the note you want to appear on the graph. The note can be up to twenty characters in length. 4. Press R. Viewing Graph Statistics To view graph statistics, do one of the following: Select. Select Graph Statistics from the View menu. The following figure shows a sample View Graph Statistics display: Working with Graphs 33

42 The following table summarizes the information in the View Graph Statistics window: Current graph Current range Legend Channel (units) Average point Lowest point Time Date Highest point Time Date Log interval Displays the name of the current graph. Displays the range for the current graph. Displays the legend identifiers for the graph. Displays the name of the logged channel. Displays the average value for each channel on the graph. Displays the value of the lowest point in the current view of the graph, along with the date and time the point occurred. Displays the value of the highest point in the current view of the graph, along with the date and time the point occurred. Displays the log interval in hours/minutes/seconds. Using Graph Menu Options Once you have created or loaded a graph, that graph becomes the current graph and the graph menu options are available. Opening an Existing Graph To open an existing graph: 1. Select Open from the Graph menu. The following window is displayed: 2. Highlight the graph you want to open and select Open. The graph you selected is displayed. 34 Chapter 5

43 Changing the Graph Type To change the type of graph: 1. Select Type from the Graph menu. The following window is displayed: 2. Highlight the type of graph: To graph multiple types of channels (for example, CO 2, aerosol, and so on), select multi-channel. To graph different tests of a single channel type (for example, two or more CO 2 tests), select single-channel. 3. Select OK. Note: You can select single-channel only when the graph contains one type of channel. To change the graph type to single-channel, first change the selected channels so that only one type of channel is selected. Refer to Changing the Graph Channels in this chapter. Changing the Graph Title To change the title of a graph: 1. Select Titles from the Graph menu. The following window is displayed: Working with Graphs 35

44 2. Enter the following: Main Title Sub title Enter a title for the graph from zero to twentyfive characters. Enter a subtitle for the graph from zero to twenty-five characters. 3. Select OK. Changing the Graph Channels To change the channels displayed in a graph: 1. Select Channels from the Graph menu. The following window is displayed: 2. Select the channels you want to display in the graph and select OK. You can select up to six channels from any combination of tests. Note: If the graph type is currently set to single-channel, you cannot select more than one type of channel. If you want to select more than one type of channel, first change the graph type to multi-channel. Refer to Changing the Graph Type in this chapter. 36 Chapter 5

45 Changing the Graph Y-Axis To change the y-axis of a graph: 1. Select Y-Axis from the Graph menu. The following dialog is displayed: 2. Enter the following: Channels Scaling Type Grid Tick Marks Range Lists the channels currently selected for display in the graph. The highlighted channel is the currently selected channel. Select the type of scaling: Automatic or Manual. When automatic is selected, TRAKPRO calculates the best range for the display of each channel. When Manual is selected, you can enter a range for each channel. Select the type of graph: Linear or Log. Turn the y-axis grid lines on or off. Enter the number of tick marks to display along the y-axis. If you have selected Manual Scaling, you can enter a high and low range for each channel. 3. Select OK. Working with Graphs 37

46 Changing the Graph X-Axis To change the x-axis of a graph: 1. Select X-Axis from the Graph menu. The following dialog is displayed: 2. Enter the following: Overlay channels Grid Range Reset Select No to display the test data in real time; select Yes to overlay the test data by ignoring the date. Turn the x-axis grid lines on or off. When No is select for Overlay channels, you can specify the range to display in the graph. Specifying a range for the graph is a more precise way of zooming in on the graph display. Resets the range values to their original values. Reset is the same as zooming out to the original graph view. 3. Select OK. Specifying Graph Legends and Markers To specify a legend and/or display markers for a graph: 1. Select Legend/Markers from the Graph menu. The following dialog is displayed: 38 Chapter 5

47 The Legend box displays the type of legend currently selected The list of channels shows the legend for each channel based on the legend type. The Show Markers determines whether markers are displayed on the graph. 2. Select the type of legend for the graph: User defined Test ID Start Date Start Time Test Abbreviation Model Serial number If you select user defined, you can enter a legend of up to ten characters for each channel in the graph display. Legends for all channels are automatically set to the test ID for each channel. Legends for all channels are automatically set to the start date for each channel. Legends for all channels are automatically set to the start time for each channel. Legends for all channels are automatically set to the abbreviation for the channel. (You can change the abbreviation for a test. Refer to Updating Test Information in chapter 4.) Legends for all channels are automatically set to the model ID for the channel. Legends for all channels are automatically set to the serial number of the logging instrument for the channel. 3. Select or de-select Show Markers. 4. Select OK. Working with Graphs 39

48 Deleting Graph Notes To delete one or more graph notes: 1. Select Notes from the Graph menu. The following window is displayed: 2. Highlight the note or notes you want to delete and select Delete. To delete all the notes, select Delete All. Changing Graph Colors To change one or more graph colors: 1. Select Colors from the Graph menu. The following window is displayed: 2. The chart shows which colors are currently selected for each channel. Highlight the channel you wish to change; then select the desired color. 40 Chapter 5

49 Saving a Graph To save the current graph: Select Save from the Graph menu. Deleting a Graph To delete a graph: 1. Select Delete from the Graph menu. The following window is displayed: 2. Highlight the graph or graphs you want to delete and select Delete. Note: Delete cannot be performed while a graph is open. Working with Graphs 41

50 Sample 1: Single-Channel Graph The following sample graph illustrates a single-channel graph showing two temperature tests: Sample 2: Single-Channel Graph with Overlayed Channels The following sample graph illustrates the same single-channel graph data shown in sample 1 with the two channels overlayed: 42 Chapter 5

51 Sample 3: Multi-Channel Graph with Overlayed Channels The following sample graph illustrates a multi-channel graph showing six channels two test readings for CO 2, two test readings for temperature, and two test readings for relative humidity: Working with Graphs 43

52 Sample 4: Multi-Channel Graph with Log Scaling The following sample graph illustrates a multi-channel graph showing two channels two test readings for aerosol. The graph data is displayed as a log graph: 44 Chapter 5

53 Chapter 6 Printing Introduction This chapter describes the following: Printing graph reports. Printing the current graph. Printing test data. Printing test statistics. Setting up the printer. Printing options. Printing Graph Reports To print a report for a graph and associated data: 1. Open a graph for which you want to print a report. 2. Select Reports from the Print menu. The following dialog is displayed: The name of the printer and current graph are displayed at the top of the dialog. If you need to change the selected printer, refer to Setting Up the Printer in this chapter. 45

54 3. Enter the following: Items to Print Report Header Select the items to print: Graph. Prints the current view of the graph. Data. Prints the associated data for each channel on the graph. The data includes the date, time, and value for each logged data point. Statistics. Prints a summary of statistics for each channel on the graph. The statistics include the average, lowest, and highest data points, along with the date and time at which the lowest and highest points occurred. Test Summary. Prints the test summary associated with each channel on the graph. Calibration Data. Prints the date and time of the last calibration for each channel on the graph. Enter a header to appear on all reports. The header can be up to 50 characters long. The header is printed on all graph reports. 4. Select Print. Printing the Current Graph To print the current graph: 1. Create a new graph or open an existing graph. 2. Select Current Graph from the Print menu. 46 Appendix A

55 Printing Test Data To print the data for an entire test: 1. Open a data file or receive test data from the logging instrument. 2. Select Test Data from the Print menu. The following dialog is displayed: 3. Select the test for which you want to print data, and enter the number of copies to print. 4. Select Print. Printing Test Statistics To print the statistics for an entire test: 1. Open a data file or receive test data from the logging instrument. 2. Select Test Statistics from the Print menu. The following dialog is displayed: Working with Graphs 47

56 3. Select the tests for which you want to print data, and enter the number of copies to print. 4. Select Print. Setting Up the Printer To set up the printer: 1. Select Printer setup from the Print menu. The printer's setup dialog will appear. You can set up the current printer or select another printer. Note: Orientation is ignored by TRAKPRO in this menu. To change printing orientation, use the Print Options. Printing Options To set printing options: 1. Select Options from the Print menu. The following dialog is displayed: 2. Select the desired graph and text orientation. 3. Select the desired print color. So printers do not support grey scale conversion of color printing, and will cause loss of detail in the printout. To correct this, select Black and White only. 4. Select Ok. 48 Appendix A

57 TSI Incorporated

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : [email protected]

More information

GX-2009 Data Logger Management Program Operator s Manual

GX-2009 Data Logger Management Program Operator s Manual GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: C Released: 3/19/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by

More information

Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..

Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions.. Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2

More information

M41 Fit Fit Test Software

M41 Fit Fit Test Software Respirator Fit Testing M41 Fit Fit Test Software User s Manual P/N 1980238, Revision B May 2004 M41 Fit Fit Test Software User s Manual P/N 1980238 Revision B May 2004 SHIP/MAIL TO: TSI Incorporated 500

More information

Corrosion Data Management Software Version 3.1.3

Corrosion Data Management Software Version 3.1.3 Corrosion Data Management Software Version 3.1.3 Metal Samples Corrosion Monitoring Systems A Division of Alabama Specialty Products, Inc. 152 Metal Samples Road, Munford, AL 36268 Phone: 256-358-4202

More information

Computer Lane Monitor for Windows

Computer Lane Monitor for Windows Computer Lane Monitor for Windows User Guide Supplement BRUNSWICK SERVICE PARTS & SUPPLIES MUSKEGON, MICHIGAN 1995, Brunswick Bowling and Billiards Corporation, 525 W. Laketon Avenue, P.O. Box 329, Muskegon,

More information

Power Log PC Application Software

Power Log PC Application Software Power Log PC Application Software Users Manual May 2007 Rev. 1, 5/08 2007-2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

SSL-Manager (SNMP-SSL Management Software)

SSL-Manager (SNMP-SSL Management Software) SSL-Manager (SNMP-SSL Management Software) User s Manual Table of Contents Chapter 1 Introduction... 3 Chapter 2 Installation... 4 Chapter 3 SSL-Manager Menus... 8 Chapter 4 Setup... 11 Chapter 5 Operation...

More information

Hydras 3 LT Quick Start

Hydras 3 LT Quick Start Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL

More information

Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to

More information

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,

More information

Gilibrator 2. Flow Monitoring Software. Version 2.0 for Windows (Windows 98 or later) USER MANUAL

Gilibrator 2. Flow Monitoring Software. Version 2.0 for Windows (Windows 98 or later) USER MANUAL Gilibrator 2 Flow Monitoring Software Version 2.0 for Windows (Windows 98 or later) USER MANUAL 16333 Bay Vista Dr. Clearwater, FL 33760 (800) 451-9444 (727) 539-0550 (FAX) Revision A Document No. 360-0049-01

More information

POS-X Stock Manager User s Guide

POS-X Stock Manager User s Guide POS-X Stock Manager User s Guide Version 1.3 Copyright 2005 POS-X Inc. All rights reserved. POS-X.com 1-800-790-8657 1 POS-X Stock Manager User s Guide Stock Manager Version 1.1.67 POS-X Inc. Telephone:

More information

VM-8 USB Desktop Audio Device Installation Guide

VM-8 USB Desktop Audio Device Installation Guide VM-8 USB Desktop Audio Device Installation Guide THE POSSIBILITIES ARE ENDLESS. 9 Austin Drive, Marlborough, CT 06447 (860) 295-8100 www.essentialtel.com [email protected] Table of Contents Introduction...3

More information

Exeba -ATS. User Guide. Escan Technologies Corporation

Exeba -ATS. User Guide. Escan Technologies Corporation Escan Technologies Corporation Exeba -ATS User Guide Escan Technologies Corp. 12140 Severn Way Riverside, CA 92503 Phone (909) 270-0043 Fax (909) 270-0920 1 ESCAN TECHNOLOGIES CORPORATION Exeba -ATS User

More information

VM-4 USB Desktop Audio Device Installation Guide

VM-4 USB Desktop Audio Device Installation Guide VM-4 USB Desktop Audio Device Installation Guide THE POSSIBILITIES ARE ENDLESS. 9 Austin Drive, Marlborough, CT 06447 (860) 295-8100 www.essentialtel.com [email protected] Table of Contents Introduction...3

More information

Getting Started with IntelleView POS Administrator Software

Getting Started with IntelleView POS Administrator Software Getting Started with IntelleView POS Administrator Software Administrator s Guide for Software Version 1.2 About this Guide This administrator s guide explains how to start using your IntelleView POS (IntelleView)

More information

USB-5100 Series. USB Data Loggers for Windows and Mac. Software Help

USB-5100 Series. USB Data Loggers for Windows and Mac. Software Help USB-5100 Series USB Data Loggers for Windows and Mac Software Help Document Revision 6 December 2015 Copyright 2015 Your new Measurement Computing product comes with a fantastic extra Management committed

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

A-Series Data Loggers PRODUCT MANUAL

A-Series Data Loggers PRODUCT MANUAL A-Series Data Loggers PRODUCT MANUAL Model # s A110, A125, A130, and A150 Contents Model Specifications 2 Connecting to the Computer 3 SpecWare Software 4 Installation and Placement 6 Battery Replacement

More information

User's Guide DylosLogger Software Version 1.6

User's Guide DylosLogger Software Version 1.6 User's Guide DylosLogger Software Version 1.6 The DylosLogger software allows users of Dylos Air Quality Monitors equipped with PC interface to easily record, download, and graph data. The COM port is

More information

JVC Monitor Calibration 2 User's Guide

JVC Monitor Calibration 2 User's Guide JVC Monitor Calibration 2 User's Guide Table of Contents 1. What is JVC Monitor Calibration 2? 2. System Requirement 3. Installation (JVC Monitor Calibration 2) 4. Uninstall 5. Installation (EyeOne Display

More information

Korosi Monitoring System (KMS) Software Manual

Korosi Monitoring System (KMS) Software Manual PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual 0RQLWRU Pulse Monitor Software Version 1 0 1 Pulse Monitor Card Software Revision 1 4 0 Pulse Monitor Card Product Revision 0 1 0 0 February, 2007 Copyright 2007,

More information

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents: PR100/PR300/PR500 Pressure Logger Operation Contents: Product Applications and Useful Features Product Specifications Operating Instructions / Getting Started DicksonWare Software Specifications Product

More information

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version 1.23.01

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version 1.23.01 User's Guide Using RFDBManager For 433 MHz / 2.4 GHz RF Version 1.23.01 Copyright Notice Copyright 2005 Syntech Information Company Limited. All rights reserved The software contains proprietary information

More information

Manual. Danfoss Central Station Communications Software Version 3

Manual. Danfoss Central Station Communications Software Version 3 Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select

More information

Event Record Monitoring and Analysis Software. Software Rev. 3.0 and Up. User s Guide

Event Record Monitoring and Analysis Software. Software Rev. 3.0 and Up. User s Guide Event Record Monitoring and Analysis Software Software Rev. 3.0 and Up User s Guide 2 Contents Contents Chapter 1: About ERMAWin 4 Chapter 2: Overview 5 About this Manual 5 System Requirements 5 Installing

More information

NDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc.

NDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc. NDA-30141 ISSUE 1 STOCK # 200893 CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications,

More information

Model 288B Charge Plate Graphing Software Operators Guide

Model 288B Charge Plate Graphing Software Operators Guide Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254

More information

PDA Software Manual For the Windows CE and Mobile Operating Systems

PDA Software Manual For the Windows CE and Mobile Operating Systems PDA Software Manual For the Windows CE and Mobile Operating Systems Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560,

More information

RDC-7 Windows XP Installation Guide

RDC-7 Windows XP Installation Guide RDC-7 Windows XP Installation Guide CONTENTS 1. End User License Agreement...3 2. Important notes...4 3. Customer support...4 4. Installing the USB driver...4 I. Prior to installation...4 II. Installation

More information

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated

More information

Table of Contents. INTRODUCTION...v. How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v

Table of Contents. INTRODUCTION...v. How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v Table of Contents INTRODUCTION...v How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v PC Hardware Requirements...vi Software Installation...vii Installing DataWorker

More information

History of Revisions. Ordering Information

History of Revisions. Ordering Information No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is

More information

Manual. Sealer Monitor Software. Version 0.10.7

Manual. Sealer Monitor Software. Version 0.10.7 Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3

More information

Sense. 3D Scanner. User Guide. See inside for use and safety information.

Sense. 3D Scanner. User Guide. See inside for use and safety information. Sense 3D Scanner User Guide See inside for use and safety information. 1 CONTENTS INTRODUCTION.... 3 IMPORTANT SAFETY INFORMATION... 4 Safety Guidelines....4 SENSE 3D SCANNER FEATURES AND PROPERTIES....

More information

Datalogger Graph Software Help

Datalogger Graph Software Help Datalogger Graph Software Help Version 2.0, August 07, 2007 For additional information refer to the user guide included on the supplied program disk. TABLE OF CONTENTS Installing Graph Software....2 Installing

More information

User s Manual C R Y S T A L. engineering corporation

User s Manual C R Y S T A L. engineering corporation DaTa LoGGerXPTM User s Manual C R Y S T A L engineering corporation DataLoggerXP User s Manual Page Contents Introduction........................................................ 1 How it works........................................................

More information

Auditcon 2 Series Software REFERENCE MANUAL

Auditcon 2 Series Software REFERENCE MANUAL Auditcon 2 Series Software REFERENCE MANUAL Trademarks The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. Auditcon PowerStar Technology

More information

2002 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or

2002 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or 041902 2002 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical, including photocopying, recording, storage

More information

Cyberex BCM-SFCM Configurator/Monitor User's Manual

Cyberex BCM-SFCM Configurator/Monitor User's Manual BRANCH/SUBFEED CIRCUIT MANAGEMENT Cyberex BCM-SFCM Configurator/Monitor User's Manual Updated: 04/01/13 Thomas & Betts Power Solutions 5900 Eastport Boulevard Richmond, VA 23231-4453 Tel: 800-238-5000

More information

Volvo Parts Corporation 04-02-03 Volvo Trip Manager. Contents

Volvo Parts Corporation 04-02-03 Volvo Trip Manager. Contents User s Manual Contents Functional Overview...4 Welcome to Volvo Trip Manager...4 About the documentation...4 Information Downloading...5 Vehicle Groups...6 Warning Messages...6 Reports...7 Trend Report...7

More information

3M Stats and Status Software for 3M Detection System Model 8900/9900. Staff Guide

3M Stats and Status Software for 3M Detection System Model 8900/9900. Staff Guide 3M Stats and Status Software for 3M Detection System Model 8900/9900 Staff Guide Copyright 2009, 3M. All rights reserved. 3M Stats and Status Software for 3M Detection System Model 8900/9900 Staff Guide

More information

Instruction manual. testo easyheat Configuration and Analysis software

Instruction manual. testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of

More information

testo easyheat Configuration and Analysis software Instruction manual

testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software Instruction manual en 2 General Information General Information This documentation includes important information about the features and application of

More information

Import Filter Editor User s Guide

Import Filter Editor User s Guide Reference Manager Windows Version Import Filter Editor User s Guide April 7, 1999 Research Information Systems COPYRIGHT NOTICE This software product and accompanying documentation is copyrighted and all

More information

FITPRO+ FIT TEST SOFTWARE VERSION 3

FITPRO+ FIT TEST SOFTWARE VERSION 3 FITPRO+ FIT TEST SOFTWARE VERSION 3 USER S MANUAL P/N 6001874, REVISION L JANUARY 2015 FITPRO+ FIT TEST SOFTWARE VERSION 3 USER S MANUAL P/N 6001874, REVISION L JANUARY 2015 SHIP/MAIL TO: TSI Incorporated

More information

Intro to Excel spreadsheets

Intro to Excel spreadsheets Intro to Excel spreadsheets What are the objectives of this document? The objectives of document are: 1. Familiarize you with what a spreadsheet is, how it works, and what its capabilities are; 2. Using

More information

Title Page. Installation Guide. PowerChute plus Version 5.0.1. for Windows 95

Title Page. Installation Guide. PowerChute plus Version 5.0.1. for Windows 95 Title Page PowerChute plus Version 5.0.1 for Windows 95 Notice Page : PowerChute plus for Windows 95 version 5.0.1 PowerChute plus License Statement This software is protected by both United States copyright

More information

User Manual. Thermo Scientific Orion

User Manual. Thermo Scientific Orion User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation

More information

Testing PCI/ISA & PCMCIA Serial Cards

Testing PCI/ISA & PCMCIA Serial Cards Serial Communications Testing PCI/ISA & PCMCIA Serial Cards Instructions on How to Use HyperTerminal to Test Serial Cards USER S MANUAL VER. 1.0 SEP 2001 No part of this manual may be reproduced without

More information

Quick Reference Manual

Quick Reference Manual Quick Reference Manual ii TABLE OF CONTENTS This guide first leads you through the basics of Logger Pro, including software installation procedures. You will learn how to collect data, manually enter data,

More information

Custom Reporting System User Guide

Custom Reporting System User Guide Citibank Custom Reporting System User Guide April 2012 Version 8.1.1 Transaction Services Citibank Custom Reporting System User Guide Table of Contents Table of Contents User Guide Overview...2 Subscribe

More information

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:

More information

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards SW43W FlukeView Power Quality Analyzer Software Version 3.20 onwards Users Manual 4822 872 30778 December 2005, Rev.1, 04/06 2005 Fluke Corporation, All rights reserved. All product names are trademarks

More information

Monitoring Network DMN

Monitoring Network DMN Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...

More information

Software Manual. For. MadgeTech 4 Data Logger Software

Software Manual. For. MadgeTech 4 Data Logger Software Software Manual For MadgeTech 4 Data Logger Software Introduction 7 About MadgeTech, Inc... 8 Software Overview 9 Getting Started... 10 System Requirements...10 Software Installation: Installing the MadgeTech

More information

General Purpose Thermal Mass Flowmeter Model 4140/4143

General Purpose Thermal Mass Flowmeter Model 4140/4143 Mass Flowmeters General Purpose Thermal Mass Flowmeter Model 4140/4143 Operation and Service Manual 1980383, Revision D January 2009 Mass Flowmeters General Purpose Thermal Mass Flowmeter Model 4140/4143

More information

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly

More information

THUM - Temperature Humidity USB Monitor

THUM - Temperature Humidity USB Monitor THUM - Temperature Humidity USB Monitor The THUM is a true USB device to monitor temperature and relative humidity of an interior living, working, and storage spaces. The THUM is ideal for computer rooms,

More information

SupcoLog Logger Interface Software

SupcoLog Logger Interface Software SupcoLog Logger Interface Software USER S GUIDE Table Of Contents Quick Start... 5 Overview... 5 Connecting the Logger to Your PC... 5 Setting Up the Logger To Record Data... 6 Custom Interval Setup...

More information

FITPRO Fit Test Software Version 2

FITPRO Fit Test Software Version 2 Respirator Fit Testing FITPRO Fit Test Software Version 2 User s Manual P/N 6001874, Revision F May 2010 Respirator Fit Testing FITPRO Fit Test Software Version 2 User s Manual P/N 6001874, Revision F

More information

for Windows Media Center User's Guide

for Windows Media Center User's Guide for Windows Media Center User's Guide Table of Contents Introduction System Requirements Installation Running HAI Home Control Using HAI Home Control Product Support Introduction Thank you for purchasing

More information

Getting Started with POS. Omni POS Getting Started Manual. switched on accounting

Getting Started with POS. Omni POS Getting Started Manual. switched on accounting Omni POS Getting Started Manual switched on accounting i i Getting Started with Omni POS Table Of Contents Overview...1 Setting up POS...2 Initial Steps...2 Tellers...2 POS Clearing Account...3 Printing...4

More information

TimeValue Software Due Date Tracking and Task Management Software

TimeValue Software Due Date Tracking and Task Management Software User s Guide TM TimeValue Software Due Date Tracking and Task Management Software File In Time Software User s Guide Copyright TimeValue Software, Inc. (a California Corporation) 1992-2010. All rights

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature

More information

CompleteView Alarm Client User s Manual. Version 3.8

CompleteView Alarm Client User s Manual. Version 3.8 CompleteView Alarm Client User s Manual Version 3.8 Table Of Contents Introduction... 1 Overview... 2 System Requirements... 2 Configuration... 3 Starting the Alarm Client... 3 Menus... 3 File Menu...

More information

File Management Utility. T u t o r i a l

File Management Utility. T u t o r i a l File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication

More information

MultiOne. Getting started

MultiOne. Getting started MultiOne Getting started Philips Lighting B.V. 2015 1 Introduction This Getting started guide covers the following topics to help you start using MultiOne: The MultiOne system The MultiOne software Working

More information

email-lead Grabber Business 2010 User Guide

email-lead Grabber Business 2010 User Guide email-lead Grabber Business 2010 User Guide Copyright and Trademark Information in this documentation is subject to change without notice. The software described in this manual is furnished under a license

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

TheFinancialEdge. Administration Guide

TheFinancialEdge. Administration Guide TheFinancialEdge Administration Guide 102011 2011 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical, including

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

How to make a line graph using Excel 2007

How to make a line graph using Excel 2007 How to make a line graph using Excel 2007 Format your data sheet Make sure you have a title and each column of data has a title. If you are entering data by hand, use time or the independent variable in

More information

SPC-1. Single Point Controller. Operation Manual

SPC-1. Single Point Controller. Operation Manual SPC-1 Single Point Controller Operation Manual NOTICE: PPM Technology Limited shall not be liable for errors that may appear herein or for incidental or consequential damages in connection with or arising

More information

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

5-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine

More information

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc. Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Operation Manual Videohub Software Control. Mac OS X Windows

Operation Manual Videohub Software Control. Mac OS X Windows Operation Manual Videohub Software Control Mac OS X Windows September 2014 Welcome We hope you share our dream for the television industry to become a truly creative industry by allowing anyone to have

More information

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

TheFinancialEdge. Administration Guide

TheFinancialEdge. Administration Guide TheFinancialEdge Administration Guide 110309 2009 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical, including

More information

Employee Appointment Books. User s Manual

Employee Appointment Books. User s Manual Employee Appointment Books User s Manual Employee Appointment Books Health District Information System HDIS (Windows Ver. 4.0 ) Copyright 1998 by CHC Software, Inc All Rights Reserved CHC Software, Inc.

More information

FLoader User's Manual

FLoader User's Manual FLoader User's Manual Version 1.0.07 Build February 12, 2002 Copyright Topcon Positioning Systems, Inc. 2002 All rights reserved Last Revised February 14, 2002 INTRODUCTION / TERMS AND CONDITIONS Thank

More information

TIME BOX User support

TIME BOX User support TIME BOX User support Should you have any comment concerning the use of this product or our services, please write to the following address: [email protected] BODET Software B.P. 40211 Boulevard du Cormier

More information

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview Data Logging Software and Cable Bundle Model DL-SC3 User Manual Overview Eco Sensors Digital Products are capable of transmitting data to a computer via an RS-232 serial connection. Eco Sensors DL-SC3

More information

Asset Track Getting Started Guide. An Introduction to Asset Track

Asset Track Getting Started Guide. An Introduction to Asset Track Asset Track Getting Started Guide An Introduction to Asset Track Contents Introducing Asset Track... 3 Overview... 3 A Quick Start... 6 Quick Start Option 1... 6 Getting to Configuration... 7 Changing

More information

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

2-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75211R/VPMA-75211R) Operates... 1 1-1 SteelVine

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

Model SL355 Noise Dosimeter/Datalogger

Model SL355 Noise Dosimeter/Datalogger Model SL355 Noise Dosimeter/Datalogger Software Help Guide Software Introduction The SL355 Noise Dosimeter software allows for setup and retrieval of recorded data in the Noise Dosimeter. A total of 20

More information

Ansur Test Executive. Users Manual

Ansur Test Executive. Users Manual Ansur Test Executive Users Manual April 2008 2008 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies Table of Contents 1 Introducing Ansur... 4 1.1 About

More information

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written

More information

Ash Capture Control User Guide

Ash Capture Control User Guide Ash Capture Control User Guide Revision 1.4 Table of Contents Software Installation... 3 Hardware Installation... 6 System Block Diagram... 7 Using Ash Capture Control... 8 Launching the Application...

More information