ELENCO PROVE ACCREDITATE - CATEGORIA: 0



Similar documents
ELENCO PROVE ACCREDITATE - CATEGORIA: 0

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

Design qualification and type approval of PV modules

INTERNATIONAL STANDARD

Introduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET)

Basic Understanding of IEC Standard Testing For Photovoltaic Panels

SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management Ver. 1

For the modifications listed below, the Qualification Approval tests in IEC and IEC 61646, shall be used as a guideline by the assessor:

FAQs-Main switchboard design criteria

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

ENVIRONMENTAL TESTING

Explosion proof enclosures

Solar energy Solar technology in endurance testing

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

INTERNATIONAL STANDARD

Technicaldata General

Long-term performance of photovoltaic modules Artur Skoczek

Safety instructions VEGADIS DIS81.CEIA/V****

RAPPORTO DI PROVA TEST REPORT

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

ENVIRONMENTAL TESTING SERVICES. Product and component performance verification

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

David O Brien, CMP Products (David.OBrien@cmp-products.com)

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

distributing & controlling system solutions

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Securing your electrical installations Prisma,

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Electrical Equipment in Hazardous Areas: Field Inspections

Introduction for Photovoltaic Power System Test in China. Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov.

TECHNICAL SPECIFICATIONS

White Paper IK code: Impact protection in line with the IEC standard. By Sven Schnautz

ISO/IEC Environmental Test Laboratory

Instructions for Safe Use

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED RED OBSTRUCTION SYSTEM

DNVGL-CP-0393 Edition December 2015

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

International PV QA Task Force (PVQAT)

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

CLASSIFICATION NOTES

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Hazardous Locations Training

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

8146/5 Series Breaker Panelboards

The role of manufacturer s in the quality of PV products

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

ERRATA CORRIGE 1. NORMA EN CEI UNI EN ISO/IEC : (CEI 31-96) Edizione: (fasc E)

Cable Trays and Ducts (Metallic)

Your Sharp system will be supplied with one of the following sets of panels:

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

High Surge Axial Cemented Wirewound Resistors

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Comparative study for cables and busbars

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES


IEC & 2 standard. The reference for safe and reliable LV switchboards

MOUNTING AND OPERATING INSTRUCTIONS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Solving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators.

Type: DILM9 10(24VDC) Article No.:

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

INTERNATIONAL STANDARD

Solar Panel Installations

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Guidance for upgrading to GB (IEC : 2005, MOD)

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version)

How To Value Trina Solar

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules

ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

New Cable Tie Type Classifications

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ex.com. ID 4016 Rev A

DEVICES OF PROTECTION AND COMMAND

THERMAL ENERGY METER MC 108/ET

SURGE PROTECTIVE DEVICES

MADE IN ITALY. Sistemi di connessione per fotovoltaico Connection systems for photovoltaic. TÜV certification EN 50521:2008 SC3

Transcription:

Scheda 1 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC 62108:2007 10.1 +IEC 61215:2005 10.1 10.10 Water spray test IEC 62108:2007 10.10 10.11 Prova termica dei diodi di bypass e di blocco / Bypass-blocking diode thermal test 10.12 Prova di robustezza delle terminazioni / Robustness of terminations test IEC 62108:2007 10.11 + IEC 61215:2005 10.18 IEC 62108:2007 10.12 + IEC 61215:2005 10.14 + IEC 60068-2-21:2006 10.13 Prova di carico meccanico / Mechanical load test IEC 62108:2007 10.13 + IEC 61215:2005 10.16 10.14 Off axis beam damage test IEC 62108:2007 10.14 10.15 Prova di condizionamento con ultravioletti / Ultraviolet conditioning test IEC 62108:2007 10.15 + IEC 61215:2005 10.10 10.16 Prova di esposizione in esterno / Outdoor exposure test IEC 62108:2007 10.16 + IEC 61215:2005 10.8 10.17 Prova di resistenza ai surriscaldamenti localizzati / Hot-spot endurance test 10.2 Misura della performance elettrica / Electrical performance measurement IEC 62108:2007 10.17 + IEC 61215:2005 10.9 IEC 62108:2007 10.2 + IEC 61215:2005 10.2 10.3 Prova di continuità a terra /Ground path continuity test IEC 62108:2007 10.3 + IEC 61730-02:2004 10.4 10.4 Prova di isolamento elettrico / Electrical insulation test IEC 62108:2007 10.4 + IEC 61215:2005 10.3 10.5 Prova di isolamento in ambiente umido / Wet insulation test IEC 62108:2007 10.5 + CEI IEC 61215:2005 10.15 10.6 Prova dei cicli termici/thermal cycling test IEC 62108:2007 10.6 + IEC 61215:2005 10.11 10.7 Prova al caldo-umido / Damp-heat test IEC 62108:2007 10.7 + IEC 61215:2005 10.13 10.8 Prova di umidità e congelamento / Humidity freeze test IEC 62108:2007 10.8 + IEC 61215:2005 10.12 10.9 Prova di impatto alla grandine / Hail impact test IEC 62108:2007 10.9 + IEC 61215:2005 10.17 Determination of the concentration factor for CPV modules M.I. 05: 02/04/2013 Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva/visual inspection IEC 61215:2005 10.1 10.10 Prova di precondizionamento UV/ UV preconditioning IEC 61215:2005 10.10 10.11 Prova dei cicli termici / Thermal cycling test IEC 61215:2005 10.11 10.12 Prova di umidità e congelamento / Humidity freeze test IEC 61215:2005 10.12 10.13 Prova al caldo umido / Damp heat test IEC 61215:2005 10.13 + IEC 60068-2-78:2001 10.14 Prova di robustezza delle terminazioni / Robustness of termination test IEC 61215:2005 10.14 + IEC 60068-2-21:2006

Scheda 2 di 9 10.15 Prova di dispersione di corrente in ambiente umido / Wet leakage current test IEC 61215:2005 10.15 10.16 Prova di carico meccanico / Mechanical load test IEC 61215:2005 10.16 10.17 Prova di grandine / Hail test IEC 61215:2005 10.17 10.18 Prova termica dei diodi di bypass / Bypass diode thermal test IEC 61215:2005 10.18 10.2 Potenza massima / Maximum power determination IEC 61215:2005 10.2 + IEC 60904-1:2006+IEC 60891:1987 10.3 Prova di isolamento / Insulation test IEC 61215:2005 10.3+ CEI EN 60068-1:1998 10.4 Misura dei coefficienti di temperatura / Measurement of temperature coefficients IEC 61215:2005 10.4 + IEC 60904-10:2009 + IEC 60891:2009 + CEI IEC 60904-1:2006 10.5 Misura della NOCT / Measurement of NOCT IEC 61215:2005 10.5 10.6 Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61215:2005 10.6 + IEC 60904-3:2008+IEC 60904-1:2006 + IEC 60904-7:2008 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61215:2005 10.7 + IEC 60904-1:2006 + IEC 60904-10:2009 10.8 Prova di esposizione in esterno / Outdoor exposure test IEC 61215:2005 10.8 + IEC 60721-2-1:2013 10.9 Prova di resistenza ai surriscaldamenti localizzati / Hot-spot endurance test Degrees of protection provided by enclosures (IP Code) 12 Tests for protection against access to hazardous parts indicated by the first characteristic numeral 13 Tests for protection against solid foreign objects indicated by the first characteristic numeral 14 Tests for protection against water indicated by the second characteristic numeral (Only IPX5,IPX6,IPX7 and IPX8) 15 Tests for protection against access to hazardous parts indicated by the additional letter IEC 61215:2005 10.9 IEC 60529:1989/A2: 2013 IEC 60529: 1989/A2: 2013 IEC 60529: 1989/A2: 2013 IEC 60529: 1989/A2: 2013 Degrees of protection provided by enclosures for electrical eqipment against external mechanical impacts (IK Code) 6 Test to verify the protection against mechanical impacts IEC 62262:2002 Enviromental testing Part 2: Tests - Test Eh: Hammer tests 4 Test EHA: Pendulum hammer IEC 60068-2-75:1997 4 Test EHC: Vertical hammer IEC 60068-2-75:1997 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state Damp heat, steady state IEC 60068-2-78:2012 Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic (sodium, chloride solution) Test Kb: Salt mist, cyclic IEC 60068-2-52:1996

Scheda 3 di 9 Environmental testing - Part 2: Tests. Test Ka: Salt mist Test Ka: Salt mist IEC 60068-2-11:1981 Explosive atmospheres Part 18: Equipment protection by encapsulation "m" 8.1.1 Water absorption test IEC 60079-18:2009 8.1.2 Dielectric strength test IEC 60079-18:2009 8.2.2 Maximum temperature IEC 60079-18:2009 8.2.3 Theramal endurance test IEC 60079-18:2009 8.2.4 Dielectric strength test IEC 60079-18:2009 8.2.5 Cable pull test IEC 60079-18:2009 8.2.6 Pressure test IEC 60079-18:2009 8.2.7 Test for resettable thermal protective device IEC 60079-18:2009 8.2.8 Sealing test for build-in protective devices IEC 60079-18:2009 Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t" 6.1.1 Type tests for dust exclusion by enclosures IEC 60079-31:2008 6.1.2 Thermal tests IEC 60079-31:2008 6.1.3 Pressure test IEC 60079-31:2008 Explosive atmospheres - Part 0: Equipment -General requirements 26.10 Resistance to light IEC 60079-0:2011 26.13 Surface resistance test IEC 60079-0:2011 26.4.2 Resistance to impact IEC 60079-0:2011 26.4.3 Drop test IEC 60079-0:2011 26.4.5 Degree of protection (IP) by enclosures IEC 60079-0:2011 26.5.1 Temperature measurement IEC 60079-0:2011 26.5.2 Thermal shock test IEC 60079-0:2011 26.5.2 Thermal shock test IEC 60079-0:2011 26.6 Torque test for bushings IEC 60079-0:2011 26.8 Thermal endurance to heat IEC 60079-0:2011 26.9 Thermal endurance to cold IEC 60079-0:2011 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" 15.1.2 Determination of explosion pressure (reference pressure) IEC 60079-1:2007 15.1.3.1 Overpressure tests IEC 60079-1:2007 15.2 Test of non-trasmission of internal ignition IEC 60079-1:2007

Scheda 4 di 9 15.4 Test of flameproof enclosures with breathing and draining devices IEC 60079-1:2007 5 Flameproof joints IEC 60079-1:2007 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety i 10.10 Transformer tests IEC 60079-11:2011 10.11 Optical isolators tests IEC 60079-11:2011 10.12 Current carrying capacity of infallible printed circuit board connections IEC 60079-11:2011 10.2 Temperature tests IEC 60079-11:2011 10.3 Dielectric strength tests IEC 60079-11:2011 10.6.1 Casting compound IEC 60079-11:2011 10.6.2 determination of the acceptability of fuses requiring encapsulation IEC 60079-11:2011 10.6.3 partitions IEC 60079-11:2011 10.9 Cable pull test IEC 60079-11:2011 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 22.12 Insulation resistance test for batteries IEC 60079-15:2010 22.3.1.1 Thermal endurance to heat IEC 60079-15:2010 22.3.1.2 Drop test for hand-held equipment IEC 60079-15:2010 22.5.1 Tests for sealed devices - Conditioning IEC 60079-15:2010 22.5.2 Tests for sealed devices- Voltage test IEC 60079-15:2010 22.7 Test for screw lampholders IEC 60079-15:2010 22.8 Test for starter holders for luminaries IEC 60079-15:2010 6.4 Clearances, creepage, distances and separations IEC 60079-15:2010 6.5 Electric strength IEC 60079-15:2010 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" 16.1 Maximum overpressure test IEC 60079-2:2007 16.2 Leakage test IEC 60079-2:2007 16.5 Verification of minimum overpressure IEC 60079-2:2007 16.6.1 Overpressure test IEC 60079-2:2007 16.7 Overpressure test for a containment system with a limited release IEC 60079-2:2007 16.8 Verifying ability of the pressurized enclosure to limit internal pressure IEC 60079-2:2007 Explosive atmospheres - Part 7: Equipment protection by increased safety "e" 6.1 Dielectric strength IEC 60079-7:2006 6.6.2 Insulation resistance IEC 60079-7:2006 6.7 General purpose connection and junction boxes IEC 60079-7:2006

Scheda 5 di 9 6.8.3 Resistance heating devices and resistance heating units IEC 60079-7:2006 6.8.4 Resistance heating devices and resistance heating units IEC 60079-7:2006 6.9 Terminal insulating material test IEC 60079-7:2006 Junction boxes for photovoltaic modules 4.3.2 Lids EN 50548:2011 4.3.2 4.4.1 Terminations and connection methods EN 50548:2011 4.4.1 4.4.4 Terminations and connection methods EN 50548:2011 4.4.4 4.8.2 Wall thickness EN 50548:2011 4.8.2 4.8.3 General construction EN 50548:2011 4.8.3 4.8.5 General construction EN 50548:2011 4.8.5 5.3.10 Prova al caldo umido/damp heat test EN 50548:2011 5.3.10 5.3.15 Resistenza all'invecchiamento / Resistance against ageing EN 50548:2011 5.3.15 5.3.16 Prova di dispersione di corrente in ambiente umido / Wet leakage current test EN 50548:2011 5.3.16 5.3.17 Prova di umidità e congelamento / Humidity freeze test EN 50548:2011 5.3.17 5.3.18 Prova termica dei diodi di bypass / Bypass diode thermal test EN 50548:2011 5.3.18 5.3.20 Knock-out inlets outlets intended to be removed by mechanical impact EN 50548:2011 5.3.20 5.3.23 Reverse current test at junction box EN 50548:2011 5.3.23 5.3.4.1 Protection against electric shock EN 50548:2011 5.3.4.1 5.3.9 Prova dei cicli termici/thermal cycle test EN 50548:2011 5.3.9 Photovoltaic (PV) modules 10.1 Ispezione visiva MST 1 / Visual inspection MST 1 IEC 61730-2:2004/A1:2011 10.1 + IEC 61215:2005 + IEC 61646:2008 + IEC 61730-1:2004/A2:2013 10.10 Prova di rottura del modulo MST 32 / Module breakage test MST 32 IEC 61730-2:2004/A1:2011 10.10 10.2 Prova di accessibilità MST 11/ Accessibility test MST 11 IEC 61730-2:2004/A1:2011 10.2 + CEI EN 61032:1998 10.3 Prova di suscettibilità al taglio MST 12 / Cut susceptibility test MST 12 IEC 61730-2:2004/A1:2011 10.3 10.4 Prova di continuità a terra MST13 / Ground continuity test MST 13 IEC 61730-2:2004/A1:2011 10.4 + IEC 61730-1:2004/A2:2013 10.5 Impulse voltage test MST14 IEC 61730-2/A1:2011 10.5 10.6 Prova di resistenza dielettrica MST 16 / Dielectric withstand test MST 16 IEC 61730-2:2004/A1:2011 10.6 + CEI EN 60068-1:1998 + IEC 61215:2005 + IEC 61646:2008 10.7 Prova di temperatura MST 21 / Temperature test MST 21 IEC 61730-2:2004/A1:2011 10.7 10.9 Prova di corrente inversa MST 26/ Reverse current overload test MST 26 IEC 61730-2:2004/A1:2011 10.9 11.2 Conduit bending test MST 33 IEC 61730-2:2004/A1:2011 11.2 11.3 Terminal box knockout tests MST 44 IEC 61730-2:2004/A1:2011 11.3

Scheda 6 di 9 Dark I-V measurement /R's measurement M.I. 01: 02/04/2013 + IEC 60891: 2009 (Method 2) + IEC 62108: 2007 10.2.4 Electroluminescence imaging test M.I. 03: 16/05/2012 Environmental testing Part 2: Test L: Dust and sand - Method Lc1: recirculating chamber Photovoltaic (PV) module safety qualification Prova di corrosione da nebbia salina/salt mist corrosion testing of photovoltaic (PV) modules EN 60068-2-68: 1996 IEC 61730-1:2004/A2:2013 IEC 61701: 2011 + IEC 60068-2-52:1996 + IEC 61215:2005 + IEC 61646:2008 + IEC 62108:2008 + IEC 61730-2:2004 Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 8 Test for first characteristic numeral IEC 60034-5:2006 9 Test for second characteristic numeral IEC 60034-5:2006 Solar collectors Thermal solar systems and components - Solar collectors - Part 2: Test methods Solar systems Thermal solar systems and components - Factory made systems - Part 2: Test methods UNI EN 12975-2:2006 UNI EN 12976-2:2006 Thin-film terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61646:2008 10.1 10.10 Prova di precondizionamento UV / UV preconditioning IEC 61646:2008 10.10 10.11 Prova dei cicli termici / Thermal cycling test IEC 61646:2008 10.11 10.12 Prova di umidità e congelamento / Humidity freeze test IEC 61646:2008 10.12 10.13 Prova al caldo umido / Damp heat test IEC 61646:2008 10.13 + IEC 60068-2-78:2012 10.14 Prova di robustezza delle terminazioni / Robustness of termination test IEC 61646:2008 10.14 + IEC 60068-2-21:2006 10.15 Prova di dispersione di corrente in ambiente umido / Wet leakage current test IEC 61646:2008 10.15 10.16 Prova di carico meccanico / Mechanical load test IEC 61646:2008 10.16 10.17 Prova di grandine / Hail test IEC 61646:2008 10.17 10.18 Prova termica dei diodi di bypass / Bypass diode thermal test IEC 61646:2008 10.18 10.19 Esposizione prolungata al sole / Light - soaking IEC 61646:2008 10.19 10.2 Potenza massima / Maximum power determination IEC 61646:2008 10.2 + IEC 60904-9:2007 + IEC 60904-1:2006 + IEC 60891:2009 10.3 Prova di isolamento/insulation test IEC 61646:2008 10.3+ CEI EN 60068-1:1998 10.4 Misura dei coefficienti di temperatura / Measurement of temperature coefficients IEC 61646:2008 10.4+ IEC 60904-1:2006 + IEC 60891:2009 + IEC 60904-10:2009 10.5 Misura della NOCT / Measurement of NOCT IEC 61646:2008 10.5

Scheda 7 di 9 10.6 Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61646:2008 10.6 + IEC 60904-3:2008 + IEC 60904-1:2006 + IEC 60904-7:2008 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61646:2008 10.7+ IEC 60904-1:2006 + IEC 60904-10:2009 10.8 Prova di esposizione in esterno / Outdoor exposure test IEC 61646:2008 10.8 + IEC 60721-2-1:2013 10.9 Prova di resistenza ai surriscaldamenti localizzati / Hot-spot endurance test IEC 61646:2008 10.9

Scheda 8 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: I Concentrator photovoltaic (CPV) modules and assemblies 10.14 Off axis beam damage test IEC 62108:2007 10.14 10.15 Prova di condizionamento con ultravioletti / Ultraviolet conditioning test IEC 62108:2007 10.15 + IEC 61215:2005 10.10 10.16 Prova di esposizione in esterno / Outdoor exposure test IEC 62108:2007 10.16 + IEC 61215:2005 10.8

Scheda 9 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: III Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61215:2005 10.1 10.2 Determinazione della massima potenza / Maximum power determination IEC 61215:2005 10.2 + IEC 60904-1:2006+ IEC 60891:2009 10.3 Prova di isolamento / Insulation test IEC 61215:2005 10.3+ CEI EN 60068-1:1998 10.4 Misura dei coefficienti di temperatura / Measurement of temperature coefficients IEC 61215:2005 10.4 + IEC 60904-10:2009 + IEC 60891:2009 + IEC 60904-1:2006 10.6 Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61215:2005 10.6 + IEC 60904-3:2008 + IEC 60904-1:2006 + IEC 60904-7:2008 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61215:2005 10.7 + IEC 60904-1:2006 + IEC 60904-10:2009 Thin-film terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61646:2008 10.1 10.2 Determinazione della massima potenza / Maximum power determination IEC 61646:2008 10.2 + IEC 60904-1:2006 + IEC 60891:2009 10.3 Prova di isolamento / Insulation test IEC 61646:2008 10.3 + CEI EN 60068-1:1998 10.4 Misura dei coefficienti di temperatura / Measurement of temperature coefficients IEC 61646:2008 10.4 + IEC 60904-1:2006 + IEC 60891:2009 + IEC 60904-10:2009 10.6 Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61646:2008 10.6 + IEC 60904-3:2008 + IEC 60904-1:2006 + IEC 60904-7:2008 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61646:2008 10.7+ IEC 60904-1:2006 + IEC 60904-10:2009 Legenda IEC=International Electrotechnical Commission CEI=Comitato Elettrotecnico Italiano EN=European Norm ANSI=American National Standards Institute UL=Underwriters Laboratories ACCREDIA Il Direttore del Dipartimento (Dr. Paolo Bianco)