ENVIRONMENTAL TESTING
|
|
|
- Chester Alexander
- 9 years ago
- Views:
Transcription
1 ENVIRONMENTAL TESTING Mobility Department
2 Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive Atmospheres Page 7 Rain - Dust - IP Enclosure Page 8 Ice- Snow Page 8 Solar Radiation Page 9 Supplement Overview Page 10 Page 11 Reliability, Quality, Safety and Compatibility If these or similar slogans apply to your products we can and would like to support you in your work. The AIT Mobility Department and its staff have many years of know-how as an independent, ISO 9001 certified testing center. We are accredited to EN and EN Expe rie n ced experts of our team are active in both Austrian and international standards boards, forming a link between standards theory and testing practice. The competitive edge provided by your staff and our technical equipment is assured in the complete product life cycle from engineering to maintenance. We support you in I Selection of test methods I Practice oriented test planning We offer you I Conducting of the tests I Conducting of acceptance tests I Long-term and life cycle tests I Reports and certificates I would be pleased if you would place your trust in us. Best regards Ing. Robert Meier Environmental Simulation Accredited Testing Laboratory/Inspection Body by decree of the Austrian Minister of Economics and Labour Ing. Robert Meier 2
3 Heat - Cold - Climate Environmental Testing I Materials testing I Display models also in 1:1 scale, doors, windows and fascade elements I Vehicle parts and vehicles, e.g. electric scooters, automobiles and rail vehicles I High temperature tests up to +250 C I Low temperature tests up to -70 C I Dew point tests from -3 C to 94 C I Climate tests: 10 % r.f up to 95 % r.f (Temperature range 10 C up to 90 C) I Rate of temperature: up to 11 C/min. I IEC IEC IEC IEC IEC IEC IEC Test A: Cold Test B: Dry heat Test N: Change of temp. Test Db: Damp heat, cyclic Test Z/AD:Composite temperature/humidity cyclic test Test Z/ABDM: Climatic sequence Test Cab: Damp heat, steady state I Temperature Chambers -40 C up to +250 C I Climate Chambers -70 C up to +180 C I Heat/Cold/Climate Test Cells (walk-in) -35 C up to +90 C I Heat/Cold/Climate Test Cells (drive-in) -50 C up to +60 C I Heat/Cold/Climate Test Chambers (drive-in) -50 C up to +50 C I IEC Semiconductor devices - Mechanical and climatic test methods I MIL-STD-810E Test Method Standard for Environmental Engineering Considerations and Laboratory Tests Drive-in climate cell 1 Climate chamber 3
4 Environmental Testing Thermal Shock Low Pressure - High Pressure I Materials testing components and devices I Rapid change between 2 temperatures (thermal shock) in air I Freely programmable sample exposure time. I Unlimited number of test cycles. I Two test chambers: High Temperature Chamber up to +180 C Low Temperature Chamber down to -70 C I Automatic sample transport I Transfer time:< 10 sec. I Capacity of the chambers: 47 x 65 x 41 cm I Max. weight of sample: 20 kg I IEC Test N: Change of temperature I IEC Semiconductor Devices Mechanical and climatic test methods I Materials testing I Mechanical constructions and structures I Vehicle parts (automobiles, aircraft and spacecraft) I Low pressure (flight test, alpine test, etc.) Low Pressure Chamber (walk-in) I Size of chamber: 1.2 m x 1.2 m x 2.3 m I Temperature range: -40 C up to +80 C I Pressure: 1 mbar up to 1300 mbar I IEC Test M: Low air pressure IEC Test Z/AM: Combined cold/low air pressure tests IEC Test Z/BM: Combined dry heat/low air pressure tests I IEC Semiconductor Devices - Mechanical and climatic test methods I MIL-STD-810F Test Method Standard for Environmental Engineering Considerations and Laboratory Tests Thermal Shock 4 Temperature-shock test chamber Vacuum chamber
5 Vibration Environmental Testing I Mechanical constructions and structures I Vehicle parts (automobiles, aircrafts and spacecrafts) Sinus Vibration I Range of frequency: 5 Hz up to 3 khz I Control of distance, speed and acceleration I Max. distance: 2 inches (peak-peak) I Max. speed: 1.8 m/s I Max. acceleration: depending on the mass of the sample incl. table 110 g (without mass) up to 40 g (with appr. 60 kg payload) Random Vibration I Range of frequency: 10 Hz up to 2 khz I Max. acceleration: 75 g (without mass) up to 10 g (with appr. 330 kg payload) Electrodynamic Shaker I Sway-direction vertical or horizontal on coupled horizontal table. I Force: N Climate Equipment I Temperature range -70 C up to +180 C, Change of temperature: 5 K/min. I Climate: 10 % r.h. up to 95 % humidity in a temperature range from 10 C up to 90 C. Prüfnormen I EN Packaging - Complete, filled transport packages -Vibration test at fixed low frequency I EN Packaging - Complete, filled transport packages -Vibration test using a sinusoidal variable frequency I IEC Test Fc: Vibration I IEC Test Z/AFc: Combined cold/vibration tests I IEC Test Z/BFc: Combined dry heat/vibration tests I IEC Test Fh: Vibration broad-band random I MIL-STD-810E Test Method Standard for Environmental Engineering Considerations and Laboratory Tests I MIL-STD-883E Test Method Standard, Microcircuits Electrodynamic shaker with adapted climate chamber 5
6 Environmental Testing Mechanical Shock I Mechanical constructions and structures I Vehicle parts (automobiles, aircrafts and spacecrafts) Electrodynamic Shaker I Sway-direction vertical or horizontal on coupled horizontal table I Force: N Single and Steady Shock Mass of sample depends on the acceleration and duration of the shock. Climate Equipment I Temperature range -70 C up to +180 C, Change of temperature: 5 K/min. I Climate: 10 % RH up to 95 % humidity in a temperature range of 10 C up to 90 C Test duration, e.g.: 6 ms: 11 ms: 232 kg at 30 g 223 kg at 30 g 126 kg at 50 g 64 kg at 50 g 6 kg at 100 g 7 kg at 60 g I IEC Test Ea: Shock IEC Test Eb: Bump IEC Test Ec: Drop and topple IEC Test Ed: Free fall IEC Test Ee: Bounce IEC Test Eh: Hammer test I MIL-STD-810E Test Method Standard for Environmental Engineering Considerations and Laboratory Tests Electrodynamic shaker with adapted climate chamber 6
7 Corrosive Atmospheres Environmental Testing I Materials testing I Mechanical constructions and structures I Vehicle parts (automobiles, aircrafts and spacecrafts) I Salt Spray (Fog) Test chamber with condensation water test I Sulphur Dioxide SO 2 and Hydrogen Sulfide H 2 S test Salt mist test with condensation water test I ASTM B117 Standard Method of Salt Spray (Fog) Testing I IEC Test Ka: Salt mist I IEC Test Kb: Salt mist, cyclic I ISO 9227 Corrosion tests in artificial atmospheres - Salt spray tests I MIL-STD-883E Test Method Standard, Microcircuits Salt Chamber I Size of chamber: L=165 cm H=120 cm D=57 cm I Temperature range: Ambient temperature up to +55 C I Also suitable for condensation water test Gas tests I IEC I IEC Test Kc: Sulphur dioxide test Test Kd: Hydrogen sulfide test Sulphur and Hydrogen Climate Chamber I Size of chamber: L=60 cm H=60 cm D=55 cm I Temperature range: +15 C up to +60 C I Humidity range: 10 % r.h. up to 80 % r.h., I Gas concentration: 0.1 ppm up to 25 ppm SO 2 and H 2 S I Also suitable for mixed corrosion gas tests Salt spray test chamber with condensation water test Climate chamber with sulphur hydrogen cell 7
8 Environmental Testing Rain - Dust - IP Enclosure Ice - Snow I Machines and technical facilities I Mechanical constructions and structures I Vehicle parts (automobiles, aircraftsand spacecrafts) I IP classification I Testing and classification of all degrees of protection for enclosures (against access to dangerous parts, solid particles, water) I Water Protection Tests: Spray water, dripping water, water jet propulsion, steam jet propulsion I Dust Chamber Dust: Talcum I Several test probes Depending on the Standard applicable I IEC I EN I ÖVE-A/EN Degrees of protection provided by enclosures (IP Code) Degrees of protection provided by enclosures (IP Code) Degrees of protection provided by enclosures (IP Code) components, machines and devices I Mechanical constructions and structures I Electric, pneumatic, hydraulic and mechanical drives I Display models also in 1:1 scale, doors, windows and fascade elements I Vehicle parts I Vehicles (automobiles, rail vehicles, aircraft and spacecraft) Analysis of samples under extreme weather conditions: I Rain I Snow I Freezing I Wind Expert reports and certificates I Water test (indoor/outdoor) I Ice/Snow/Climate Chamber Depending on the applicable product standard (examples): I IEC High-voltage switchgear and controlgear - Part 102: High-voltage alternating current disconnectors and earthing switches Water protection test equipment Device under weathering 8
9 Solar Radiation Environmental Testing I Materials testing I Building climate I Solar collectors and photovoltaic elements I Mechanical constructions and structures I Electric, pneumatic, hydraulic and mechanical drives I Scale models of doors, windows and facade elements I Vehicles (automobiles, rail vehicles, aircraft and spacecraft) I Solar collector tests according to the standards I Simulation of solar radiation on the earth`s surface I Simulation of UV radiation UV radiation range from 0.28 µm up to 0.40 µm I Solar collector test stand with automatic data logging I Solar Simulator up to 1000 W/m 2 also in combination with cold-heat climate chambers (walk-in and drive-in) I UV chamber 2380 x 2380 x 1650 mm I Temperatures from -40 C up to + 80 C I EN Termal solar systems and components - Solar collectors Part 2: Test methods I IEC Test Sa: Simulated solar radiation at ground level I MIL-STD-810E Test Method Standard for Environmental Engineering Considerations and Laboratory Tests Solar collector test stand Solar simulator 9
10 Environmental Testing SUPPLEMENT I ASTM B117 Standard Method of Salt Spray (Fog) Testing I EN Thermal Solar Systems and Components - Solar Collectors Part 2: Test Methods I EN Packaging - Complete, filled transport packages - Vibration test at fixed low frequency I EN Packaging - Complete, filled transport packages - Vibration test using a sinusoidal variable frequency I IEC Test A: Cold I IEC Test B: Dry heat I IEC Test Sa: Simulated solar radiation at ground level I IEC Test Fc: Vibration I IEC Test Ka: Salt mist I IEC Test M: Low air pressure I IEC Test N: Change of temperature I IEC Test Ea: Shock I IEC Test Eb: Bump I IEC Test Db: Damp heat, cyclic I IEC Test Ec: Drop and topple I IEC Test Ed: Free fall I IEC Test Z/AD: Composite temperature/humidity cyclic test I IEC Test Z/AM: Combined cold/low air pressure tests I IEC Test Z/BM: Combined dry heat/low air pressure tests I IEC Test Kc: Sulphur dioxide test I IEC Test Kd: Hydrogen sulfide test I IEC Test Z/AFc: Combined cold/vibration tests I IEC Test Z/BFc: Combined dry heat/vibration tests I IEC Test Kb: Salt mist, cyclic I IEC Test Ee: Bounce I IEC Test Z/ABDM: Climatic sequence I IEC Test Fh: Vibration broad-band random I IEC Test Eh: Hammer test I IEC Test Cab: Damp heat, steady state I IEC Semiconductor devices - Mechanical and climatic test methods I ISO 9227 Corrosion tests in artificial atmospheres - Salt spray tests I MIL-STD-810F Test Method Standard for Environmental Engineering Considerations and Laboratory Tests 10
11 SUPPLEMENT Environmental Testing Test Equipment Test equipment Temperature range Humidity range Size (L x W x D) Temperature chamber -70 C to +180 C - 58 x 62 x 75 cm Temperature chamber -70 C to +180 C - 80 x 65 x 95 cm Temperature chamber -70 C to +180 C - 58 x 62 x 75 cm Temperature chamber 20 C to +250 C - 40 x 40 x 40 cm Temperature chamber 20 C to +180 C - 58 x 38 x 48 cm Temperature chamber 20 C to +180 C - 58 x 38 x 48 cm Temperature chamber 20 C to +180 C - 58 x 38 x 48 cm Climatic chamber -70 C to +180 C 15 % r.h. to 98 % r.h. 80 x 65 x 92cm Climatic chamber -10 C to +180 C 11 % r.h. to 98 % r.h. 52 x 47 x 48 cm Climatic chamber -30 C to +180 C 12 % r.h. to 98 % r.h. at +10 C to +90 C 55 x 54 x 64 cm Climatic chamber -45 C to +60 C - 6,0 x 3,2 x 3,0 m Climatic chamber -40 C to +90 C 15 % r.h. to 95 % r.h. 3.2 x 2.0 x 2.0 m Climatic chamber (UV cell) -40 C to +80 C x 2.3 x 1.6 m Climatic chamber -75 C to +120 C 15 % r.h. to 95 % r.h. 2.0 x 1.3 x 2.6 m Climatic chamber -40 C to +80 C 15 % r.h. to 95 % r.h. 4.1 x 5.3 x 3.1 m Shock temperature chamber -80 C to +220 C - 47 x 65 x 41 cm Gas climate chamber -70 C to +180 C 12 % r.h. to 98 % r.h. 82 x 80 x 85 cm Salt spray chamber RT to +55 C 50 % r.h. to 100 % r.h. 120 x 165 x 57 cm Low pressure chamber -40 C to +80 C x 1.2 x 2.3 m Dust chamber x 1.7 x 1.5 m Spray water test equipment Vibration and mechanical shock test equipment Solar collector test equipment x 2.5 x 3.0 m -70 C to +180 C 10 % r.h. to 95 % r.h. 100 x 100 x 100 cm Solar simulator - - Modular up to 20 m 2 11
12 Contact AIT Austrian Institute of Technology Giefinggasse 2, 1210 Vienna, Austria Ing. Robert Meier Electric Drive Technologies Mobility Department T +43 (0) F +43 (0) E [email protected]
ENVIRONMENTAL TESTING SERVICES. Product and component performance verification
ENVIRONMENTAL TESTING SERVICES Product and component performance verification environmental testing State-of-the-art technology and increased demands for product and component reliability have intensified
ETSI EN 300 019-2-2 V2.1.2 (1999-09)
EN 300 019-2-2 V2.1.2 (1999-09) European Standard (Telecommunications series) Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-2: Specification
Sebert Group Structure Sebert Schwingungstechnik GmbH
Sebert Group Structure Sebert Schwingungstechnik GmbH S2T-Romania S2T-NL S2T-D-Nord Consultancy Test-Lab Sales The Sebert Group has got in total 60 employees and exist for more than 30 years Sebert Trillingstechniek
ETSI EN 300 019-2-7 V3.0.1 (2003-04)
EN 300 019-2-7 V3.0.1 (2003-04) European Standard (Telecommunications series) Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-7: Specification of environmental
EUROPEAN ETS 300 019-1-4 TELECOMMUNICATION February 1992 STANDARD
EUROPEAN ETS 300 019-1-4 TELECOMMUNICATION February 1992 STANDARD Source: ETSI TC-EE Reference: DE/EE-1019-1-4 ICS: 33.080 Key words: Environment, test, equipment Equipment Engineering (EE); Environmental
Solar energy... ...Solar technology in endurance testing
Solar energy......solar technology in endurance testing Solar & Photovoltaic systems - Environmental testing...... we are your partner Energy generated by the sun (solar energy) is considered forward looking
ZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
Espotel Test Laboratory Services. November 20, 2014
Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN
ZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
High-ohmic/high-voltage resistors
FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS
ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
High-ohmic/high-voltage resistors
FEATURES High pulse loading capability Small size. APPLICATIONS Where high resistance, high stability and high reliability at high voltage are required High humidity environment White goods Power supplies.
ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
ZS10 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting
White Paper IK code: Impact protection in line with the IEC 62 262 standard. By Sven Schnautz
White Paper IK code: Impact protection in line with the IEC 62 262 standard By Sven Schnautz Contents List of images... 3 List of tables... 3 List of figures... 3 Introduction... 4 Basic principles...
ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT
STANDARD FOR CERTIFICATION No. 2.4 ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT APRIL 2006 FOREWORD (DNV) is an autonomous and independent foundation with the objectives
COMITÉ EUROPÉEN DES ASSURANCES
COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,
Shock and Vibration Testing
Shock and Vibration Testing Agenda Shock Testing Comparison and Selection of Methods Comparison of Specs Rationale for Selection of Testing Vibration Testing Comparison and Selection of Methods Comparison
Design qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
ISO/IEC 17025 Environmental Test Laboratory
ISO/IEC 17025 Environmental Test Laboratory Fast and reliable IEC qualified assessment laboratory for electronic components (IECQ) Environmental testing, consisting of the complete range of mechanical,
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Automotive Application Questionnaire for Electronic Control Units and Sensors. Electronic Components and Systems
Automotive Application Questionnaire for Electronic Control Units and Sensors Electronic Components and Systems Automotive Application Questionnaire for Electronic Control Units and Sensors Published by:
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
HyLife TM HVAC Line Corrosion testing. Precision Tubing Technology Centre, 2012
Precision Tubing Technology Centre, 2012 Background: There is an increasing interest in the use of aluminium tubes for connecting lines for residential HVACR applications Connecting lines are often covered
Plug-in relays Mini ISO relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of
Standard Thick Film Chip Resistors
Standard Thick Film Chip Resistors FEATURES Stability R/R = 1 % for 00 h at 70 C 2 mm pitch packaging option for size Pure tin solder contacts on Ni barrier layer provides compatibility with lead (Pb)-free
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
High Ohmic (up to 68 MΩ)/ High Voltage (up to 10 kv) Resistors
High Ohmic (up to 68 MΩ)/ A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded to the end-caps.
Secure Data Drive Safe storage of sensitive data in harsh environments
Secure Data Drive Safe storage of sensitive data in harsh environments www.fischerconnectors.com FISCHER RUGGED FLASH DRIVE KEY FEATURES SAFE STORAGE IP68 sealed even unmated Extreme temperature resistant
Degrees of protection. IP codes. W.M.M. Menheere Holec Holland N.V. The Netherlands
Degrees of protection IP codes W.M.M. Menheere Holec Holland N.V. The Netherlands 1 INDEX Introduction...3 1. The IEC protection code (International Protection IP)...3 2. Interpreting the IP code...3 3.
Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK
code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475
Product Specification Micro-SIM H1.24 Push-Pull Type 108. This specification covers the requirements for product performance, test methods and quality
Product Specification Micro-SIM H1.24 Push-Pull Type 108 09. Jan 13 1. Scope : 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions
Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere
Humidity, Condensation, Clouds, and Fog or Water in the Atmosphere The Hydrologic Cycle Where the Water Exists on Earth Evaporation From the Oceans and Land The Source of Water Vapor for the Atmosphere
Weiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3
2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro
3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max
1. GENERAL 1. 1 Application : This specification is applied to MULTI WAY SWITCH for electronic equipment. 1. 2 Operating Temperature Range :-25 ~ 70 1. 3 Storage Temperature Range :-0 ~ 85. However, 96
ELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 7 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva/visual inspection IEC 61215:2005 10.1 10.10 Prova di precondizionamento
High Ohmic/High Voltage Metal Glaze Leaded Resistors
VR37 High Ohmic/High Voltage FEATURES A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment
fischer Rugged Flash Drive New Rugged Solution for Safe Data Storage in Harsh Environment Headquarters Fischer Connectors SA Ch. du Glapin 20 1162 Saint-Prex Switzerland Phone +41 21 800 95 95 [email protected]
Technical application guide IP codes in accordance with IEC 60529
www.osram.com Technical application guide IP codes in accordance with IEC 60529 What are IP codes? Depending on their potential exposure to foreign objects, electrical devices (e.g. luminaires, LED modules
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
How To Make A Lightweight Car
Lightweight solutions Multi-material constructions Flanders DRIVE Index: Flanders DRIVE 1 Need for cost-efficient lightweight solutions 2 Multi-material constructions as a valuable solution 3 Our expertise
Environment-Laboratory Ambient Conditions
ISSUE 3.0: MADE MINOR CLARIFICATION CHANGES. FOR CLIENT LABS Purpose To assure laboratory conditions are stable during the performance of testing and data collection. Why this requirement is important?
Specifications for DRIVER S REAR VIEW CAMERA
Specifications for DRIVER S REAR VIEW CAMERA August 2001 Sekai Electronics Inc. 13570 Larwin Circle Santa Fe Springs CA-90670 U.S.A. General Description Introduction A camera system designed to assist
Accelerated Aging and Life Time Prediction for Solar Concentrators
Chart 1 Accelerated Aging and Life Time Prediction for Solar Concentrators CSP Today 2015, Sevilla J. Wette, F. Sutter (DLR) A. Fernandez (CIEMAT) Chart 2 Contents Motivation/Solar mirrors Outdoor testing
DC/DC CONVERTER Environmental Test Report
DC/DC CONVERTER al Test Report al Test Report on GAÏA Converter DC/DC Module 1 Scope This report presents the environmental tests conducted on GA ÏA Converter DC/DC modules and the different results obtained
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
Operational experienced of an 8.64 kwp grid-connected PV array
Hungarian Association of Agricultural Informatics European Federation for Information Technology in Agriculture, Food and the Environment Journal of Agricultural Informatics. 2013 Vol. 4, No. 2 Operational
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Precision Leaded Resistors
FEATURES Approved according to CECC 40101-806 Advanced thin film technology Low TC: ± 15 to Precision tolerance of value: ± 0.1 % and ± 0.25 % Superior overall : class 0.05 Wide precision range: 10 Ω to
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
Instruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007
Instruction book IQAN-MDM Publ. no. HY17-8328/UK Edition June, 2007 Contents 1 Introduction...............................................................3 Safety symbols................................................................
Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008
Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification
THE HUMIDITY/MOISTURE HANDBOOK
THE HUMIDITY/MOISTURE HANDBOOK Table of Contents Introduction... 3 Relative Humidity... 3 Partial Pressure... 4 Saturation Pressure (Ps)... 5 Other Absolute Moisture Scales... 8 % Moisture by Volume (%M
Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation
Outline MAE 493R/593V- Renewable Energy Devices Solar Energy Electromagnetic wave Solar spectrum Solar global radiation Solar thermal energy Solar thermal collectors Solar thermal power plants Photovoltaics
WEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
Pulse Proof Thick Film Chip Resistors
Pulse Proof Thick Film Chip Resistors FEATURES High pulse performance, up to kw Stability R/R 1 % for h at 70 C AEC-Q200 qualified Material categorization: for definitions of compliance please see www.vishay.com/doc?99912
High Surge Axial Cemented Wirewound Resistors
High Surge Axial Cemented Wirewound Resistors FEATURES High voltage surge (up to 12 kv) withstanding capability Non flammable silicon cement coating High grade ceramic core Material categorization: for
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
How do I measure the amount of water vapor in the air?
How do I measure the amount of water vapor in the air? Materials 2 Centigrade Thermometers Gauze Fan Rubber Band Tape Overview Water vapor is a very important gas in the atmosphere and can influence many
Securing your electrical installations Prisma,
Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
HELLA MEANS QUALITY EXCELLENCE SINCE 1899
HELLA MEANS QUALITY EXCELLENCE SINCE 1899 QUALITY CRITERIA 03 HELLA MEANS QUALITY HELLA has set itself the ambitious aim of guaranteeing a consistently high level of product quality in every respect.
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
High Ohmic/High Voltage Metal Glaze Leaded Resistors
High Ohmic/High Voltage FEATURES A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded to
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
AC and Pulse Film Foil Capacitors KP Radial Potted Type
AC and Pulse Film Foil Capacitors KP Radial Potted Type 0.5 L max. W max. Marking H max. FEATURES 5 mm lead pitch, supplied loose in box taped in ammopack or reel Material categorization: for definitions
Specification of 5 Wire Analog Touch Panel
Specification of 5 Wire Analog Touch Panel 5 WIRE ANALOG RESISTIVE TOUCH PANEL A. Application This specification applies to the 5 Wire Analog Resistive Touch Panel. B. Environmental Conditions 1. Operating
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Additional Requirements
VdS Guidelines for Smoke Alarm Devices VdS 3131en Requirements and Test Methods VdS 3131en : 2010-05 (01) Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 174 50735 Köln, Germany
High Ohmic/High Voltage Metal Film Leaded Resistors
, High Ohmic/High Voltage FEATURES Metal film technology High pulse loading (up to 10 kv) capability Small size (0207/0411) Compatible with lead (Pb)-free and lead containing soldering processes Compliant
Annex of the certificate (Page 1/6) Accreditation Scope
As a Testing Laboratory Annex of the certificate (Page 1/6) Accreditation Scope Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli 35681 İZMİR / TÜRKİYE Phone : 0 232 376 24 25 Fax : 0 232 386 33 98 E-Mail
Definition of classes and info material to manufacturers related to EN ISO 9806
SP Sveriges Tekniska Forskningsinstitut Definition of classes and info material to manufacturers related to EN ISO 9806 SP Sveriges Tekniska Forskningsinstitut Classmate: Definition of classes and drafting
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Vibration Test for Large Lithium-ion Battery Assemblies on UN Transportation Manual of Tests & Criteria JARI
Vibration Test for Large Lithium-ion Battery Assemblies on UN Transportation Manual of Tests & Criteria JARI Battery Transportation Working Group Working Group on the Testing of and Criteria for Lithium
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
ELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC 62108:2007 10.1 +IEC 61215:2005 10.1 10.10 Water
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
California Standards Grades 9 12 Boardworks 2009 Science Contents Standards Mapping
California Standards Grades 912 Boardworks 2009 Science Contents Standards Mapping Earth Sciences Earth s Place in the Universe 1. Astronomy and planetary exploration reveal the solar system s structure,