1 Scheda 1 di 7 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva/visual inspection IEC 61215: Prova di precondizionamento UV/ UV preconditioning IEC 61215: Prova dei cicli termici / Thermal cycling test IEC 61215: Prova di umidità e congelamento / Humidity freeze test IEC 61215: Prova al caldo umido / Damp heat test IEC 61215: IEC : Prova di robustezza delle terminazioni / Robustness of termination test IEC 61215: IEC : Prova di dispersione di corrente in ambiente umido / Wet leakage current test IEC 61215: Prova di carico meccanico / Mechanical load test IEC 61215: Prova di grandine / Hail test IEC 61215: Prova termica dei diodi di bypass / Bypass diode thermal test IEC 61215: Potenza massima / Maximum power determination IEC 61215: IEC :2006+IEC 60891: Prova di isolamento / Insulation test IEC 61215: CEI EN :2013 IEC 61215: IEC + IEC 60891: CEI IEC : Misura della NOCT / Measurement of NOCT IEC 61215: Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61215: IEC :2008+IEC 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61215: IEC : IEC 10.8 Prova di esposizione in esterno / Outdoor exposure test IEC 61215: IEC : Prova di resistenza ai surriscaldamenti localizzati / Hot-spot endurance test Degrees of protection provided by enclosures (IP Code) 12 Tests for protection against access to hazardous parts indicated by the first characteristic numeral 13 Tests for protection against solid foreign objects indicated by the first characteristic numeral 14 Tests for protection against water indicated by the second characteristic numeral (Only IPX3, IPX4, IPX5,IPX6,IPX7, IPX8 and IPX9) 15 Tests for protection against access to hazardous parts indicated by the additional letter IEC 61215: IEC 60529:1989/A2: 2013 IEC 60529: 1989/A2: 2013 IEC 60529: 1989/A2: 2013 IEC 60529: 1989/A2: 2013 IP6X-IP5X on huge size enclosure M.I. 24: 02/04/ IEC 60529:1989/A2: 2013 Degrees of protection provided by enclosures for electrical eqipment against external mechanical impacts (IK Code) 6 Test to verify the protection against mechanical impacts IEC 62262:2002 Enviromental testing Part 2: Tests - Test Eh: Hammer tests 4 Test EHA: Pendulum hammer IEC :2014
2 Scheda 2 di 7 6 Test EHC: Vertical hammer IEC :2014 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state Damp heat, steady state IEC :2012 Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic (sodium, chloride solution) Test Kb: Salt mist, cyclic IEC :1996 Environmental testing - Part 2: Tests. Test Ka: Salt mist Test Ka: Salt mist IEC :1981 Explosive atmospheres Part 18: Equipment protection by encapsulation "m" Water absorption test IEC : Dielectric strength test IEC : Maximum temperature IEC : Theramal endurance test IEC : Dielectric strength test IEC : Cable pull test IEC : Pressure test IEC : Test for resettable thermal protective device IEC : Sealing test for build-in protective devices IEC :2014 Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t" Type tests for dust exclusion by enclosures IEC : Thermal tests IEC :2013 Explosive atmospheres - Part 0: Equipment -General requirements Earth continuity IEC : Surface resistance test IEC : Measurement of capacitance IEC : Verification of ratings of ventilating fans IEC : Alternative qualification of elastomeric sealing O-rings IEC : Tests in explosive test mixtures IEC : Resistance to impact IEC : Drop test IEC : Degree of protection (IP) by enclosures IEC : Temperature measurement IEC : Thermal shock test IEC : Small component ignition test IEC : Torque test for bushings IEC : Test temperature IEC :2011
3 Scheda 3 di Thermal endurance to heat IEC : Thermal endurance to cold IEC :2011 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Determination of explosion pressure (reference pressure) IEC : Overpressure tests IEC : Test of non-trasmission of internal ignition IEC : Flameproof joints IEC :2014 C Torque test for Ex thread adapters IEC :2014 C Impact test for Ex thread adapters IEC :2014 C Over-pressure test for Ex thread adapters IEC :2014 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety i 10.1 Spark ignition test IEC : Transformer tests IEC : Current carrying capacity of infallible printed circuit board connections IEC : Temperature tests IEC : Dielectric strength tests IEC : Tests for cells and batteries IEC : Casting compound IEC : determination of the acceptability of fuses requiring encapsulation IEC : partitions IEC : Type tests for diode safety barriers and safety shunts IEC : Cable pull test IEC :2011 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" Mechanical shock test for batteries IEC : Insulation resistance test for batteries IEC : Thermal endurance to heat IEC : Drop test for hand-held equipment IEC : Tests for sealed devices - Conditioning IEC : Tests for sealed devices- Voltage test IEC : Restricted breathing test IEC : Clearances, creepage, distances and separations IEC : Electric strength IEC :2010 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" 16.1 Determination of Maximum overpressure rating IEC : Maximum overpressure test IEC : Leakage test IEC : Purging test IEC :2014
4 Scheda 4 di Purging and diluition tests for a pressurized enclosure with an internal source of release IEC : Verification of minimum overpressure IEC : Overpressure test IEC : Overpressure test for a containment system with a limited release IEC :2014 Explosive atmospheres - Part 7: Equipment protection by increased safety "e" 6.1 Dielectric strength IEC : Terminal insulating material test IEC : /6.7.2 Insulation resistance IEC : /6.7.3 Batteries - mechanical shock test IEC : /6.7.4 Ventilation for cells and battery of Level of Protection "eb"/"ec" IEC : General purpose connection and junction boxes IEC : Resistance heating equipments IEC :2015 Flame arresters 6.7 Flow measurement (air) EN ISO 16852: Deflagration test - End of-line flame arrester EN ISO 16852:2010 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic methods and requirements 8.2 Determination of the maximum surface temperature UNI EN : Test for resistance to impact UNI EN : Drop test UNI EN : Thermal endurance to heat UNI EN : Thermal endurance to cold UNI EN : Mechanical resistance tests UNI EN : Surface resistance test UNI EN : Thermal shock test UNI EN : 2009 Non-electrical equipment for use in potentially explosive atmospheres - Part 5: Protection by constructional safety "c" B.1 "Dry run" test for lubricated sealing arrangements UNI EN :2011 B.2 Type test for determining the maximum engaging time of clutch assembly UNI EN :2011 B.3 Conductivity criteria for trasmission belts UNI EN :2011 Photovoltaic (PV) modules 10.1 Ispezione visiva MST 1 / Visual inspection MST 1 IEC :2004/A1: IEC 61215: IEC 61646: IEC :2004/A2: Prova di rottura del modulo MST 32 / Module breakage test MST 32 IEC :2004/A1: Prova di accessibilità MST 11/ Accessibility test MST 11 IEC :2004/A1: CEI EN 61032: Prova di suscettibilità al taglio MST 12 / Cut susceptibility test MST 12 IEC :2004/A1: Prova di continuità a terra MST13 / Ground continuity test MST 13 IEC :2004/A1: IEC :2004/A2: Impulse voltage test MST14 IEC /A1:
5 Scheda 5 di Prova di resistenza dielettrica MST 16 / Dielectric withstand test MST 16 IEC :2004/A1: CEI EN : IEC 61215: IEC 61646: Prova di temperatura MST 21 / Temperature test MST 21 IEC :2004/A1: Prova di corrente inversa MST 26/ Reverse current overload test MST 26 IEC :2004/A1: Conduit bending test MST 33 IEC :2004/A1: Terminal box knockout tests MST 44 IEC :2004/A1: Dark I-V measurement /R's measurement M.I. 01: 02/04/ IEC 60891: 2009 (Method 2) + IEC 62108: Electroluminescence imaging test M.I. 03: 16/05/2012 Environmental testing Part 2: Test L: Dust and sand - Method Lc1: recirculating chamber Photovoltaic (PV) module safety qualification Prova di corrosione da nebbia salina/salt mist corrosion testing of photovoltaic (PV) modules EN : 1996 IEC :2004/A2:2013 IEC 61701: IEC : IEC 61215: IEC 61646: IEC 62108: IEC :2004/A1:2011 Reciprocating internal combustion engines - Safety requirements for design and construction of engines for use in potentially explosive atmospheres - Part 1: Group II engines for use in flammable gas and vapour atmospheres Determination of the maximum explosion pressure EN : Overpressure test EN : Non trasmission tests EN :2000 Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 8 Test for first characteristic numeral IEC : Test for second characteristic numeral (Only IPX3, IPX4, IPX5, IPX6, IPX8 and IPX9) IEC :2006 Solar energy Solar thermal collectors Test methods 10 Standard stagnation temperature of liquid heating collectors EN ISO 9806: Exposure and pre-exposure test EN ISO 9806: External thermal shock test EN ISO 9806: Internal thermal shock test EN ISO 9806: Rain penetration test EN ISO 9806: Freeze resistance test EN ISO 9806: Mechanical load test with positive or negative pressure EN ISO 9806: Impact resistance test EN ISO 9806: Final inspection EN ISO 9806: Performance testing of fluid heating collectors EN ISO 9806: Internal pressure tests for fluid channels EN ISO 9806: High-temperature resistance test EN ISO 9806:2013 Thermal solar systems and components - Solar collectors - Part 1: General requirements General requirements UNI EN :2011
6 Scheda 6 di 7 Thin-film terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61646: Prova di precondizionamento UV / UV preconditioning IEC 61646: Prova dei cicli termici / Thermal cycling test IEC 61646: Prova di umidità e congelamento / Humidity freeze test IEC 61646: Prova al caldo umido / Damp heat test IEC 61646: IEC : Prova di robustezza delle terminazioni / Robustness of termination test IEC 61646: IEC : Prova di dispersione di corrente in ambiente umido / Wet leakage current test IEC 61646: Prova di carico meccanico / Mechanical load test IEC 61646: Prova di grandine / Hail test IEC 61646: Prova termica dei diodi di bypass / Bypass diode thermal test IEC 61646: Esposizione prolungata al sole / Light - soaking IEC 61646: Potenza massima / Maximum power determination IEC 61646: IEC : IEC : IEC 60891: Prova di isolamento/insulation test IEC 61646: CEI EN :2013 IEC 61646: IEC : IEC 60891: IEC 10.5 Misura della NOCT / Measurement of NOCT IEC 61646: Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61646: IEC : IEC 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61646: IEC : IEC 10.8 Prova di esposizione in esterno / Outdoor exposure test IEC 61646: IEC : Prova di resistenza ai surriscaldamenti localizzati / Hot-spot endurance test IEC 61646:
7 Scheda 7 di 7 ELENCO PROVE ACCREDITATE - CATEGORIA: III Crystalline silicon terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61215: Determinazione della massima potenza / Maximum power determination IEC 61215: IEC :2006+ IEC 60891: Prova di isolamento / Insulation test IEC 61215: CEI EN :1998 IEC 61215: IEC + IEC 60891: IEC : Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61215: IEC : IEC 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61215: IEC : IEC Thin-film terrestrial photovoltaic (PV) modules 10.1 Ispezione visiva / Visual inspection IEC 61646: Determinazione della massima potenza / Maximum power determination IEC 61646: IEC : IEC 60891: Prova di isolamento / Insulation test IEC 61646: CEI EN :1998 IEC 61646: IEC : IEC 60891: IEC 10.6 Prestazioni al STC e alla NOCT / Performance at STC and NOCT IEC 61646: IEC : IEC 10.7 Prestazioni a basso irraggiamento / Performance at low irradiance IEC 61646: IEC : IEC Legenda IEC=International Electrotechnical Commission CEI=Comitato Elettrotecnico Italiano EN=European Norm ANSI=American National Standards Institute UL=Underwriters Laboratories ACCREDIA Il Direttore del Dipartimento (Dr.ssa Silvia Tramontin)
ELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 8 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC62108:2007 10.1 + CEI IEC 61215:2005 10.1 10.10
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC 62108:2007 10.1 +IEC 61215:2005 10.1 10.10 Water
More informationDesign qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008
Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification
More informationDesign qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
More informationPV module safety qualification according to IEC 61730:2004 EN 61730:2007
PV module safety qualification according to IEC 61730:2004 EN 61730:2007 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies January 2009 Version 2009-01-22 Overview The long term
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61215 Second edition 2005-04 Crystalline silicon terrestrial photovoltaic (PV) modules Design qualification and type approval This English-language version is derived from the
More informationIntroduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET)
Introduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET) 2015 PV Module Reliability Workshop Golden, Colorado, Thursday, February 26, 2015 Tadashi Obayashi,
More informationINTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
More informationSFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management 2015.07 Ver. 1
SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan ARC Product Management 2015.07 Ver. 1 Outline SLIDE 1 2 Outline What is PID? TOPICS 3 4 5 6 7 8 Principle of PID & resistance
More informationBasic Understanding of IEC Standard Testing For Photovoltaic Panels
Basic Understanding of IEC Standard Testing For Photovoltaic Panels Regan Arndt and Dr. Ing Robert Puto TÜV SÜD Product Service The photovoltaic industry has experienced incredibly fast transformation
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationENVIRONMENTAL TESTING
ENVIRONMENTAL TESTING Mobility Department Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock
More informationEx q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
More informationHazardous Locations Training
Hazardous Locations Training If you are involved with projects associated with hazardous locations, which involves the installation or inspection and maintenance of electrical or non-electrical e.g. mechanical;
More informationFor the modifications listed below, the Qualification Approval tests in IEC 61215 and IEC 61646, shall be used as a guideline by the assessor:
Product or Process Modifications Requiring Limited CBTL Retesting to Maintain Certification This document sets forth a uniform approach to maintain the certification of products that have, or will, undergo
More informationDavid O Brien, CMP Products (David.OBrien@cmp-products.com)
David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
More informationElectrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 9 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Anelli per alpinismo Information supplied by the manufacturer (Verifica conformità) EN 566:2006 clausola 7 Marking (Verifica conformità) EN 566:2006
More informationdistributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
More informationSHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010
SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare
More informationCLASSIFICATION NOTES
CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification
More informationSafety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
More informationSolar energy... ...Solar technology in endurance testing
Solar energy......solar technology in endurance testing Solar & Photovoltaic systems - Environmental testing...... we are your partner Energy generated by the sun (solar energy) is considered forward looking
More informationFAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
More informationComparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
More informationWhat are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
More informationSOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationENVIRONMENTAL TESTING SERVICES. Product and component performance verification
ENVIRONMENTAL TESTING SERVICES Product and component performance verification environmental testing State-of-the-art technology and increased demands for product and component reliability have intensified
More informationERRATA CORRIGE 1. NORMA EN CEI UNI EN ISO/IEC 80079-34: (CEI 31-96) Edizione: 2012-03 (fasc. 11822E)
ERRATA CORRIGE 1 NORMA EN CEI UNI EN ISO/IEC 80079-34: (CEI 31-96) Edizione: 2012-03 (fasc. 11822E) Atmosfere esplosive Parte 34: Applicazione dei sistemi di gestione per la qualità per la fabbricazione
More informationALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
More informationSafety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
More informationLong-term performance of photovoltaic modules Artur Skoczek
1 Long-term performance of photovoltaic modules Artur Skoczek 2 The European Solar Test Installation (ESTI) has the primary objective of providing the scientific and technological basis for a sound and
More information12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
More informationMT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
More informationSecuring your electrical installations Prisma,
Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards
More informationPOINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED RED OBSTRUCTION SYSTEM
Compliances: ETL Listed to UL 1598 ETL Listed to CSA C22.2 No.250.0-04 Canada FAA Approved L-810 & L-864 by Advisory Circular 150/5345-43G Verified to ICAO Annex 14 Registered ISO 9001: 2008 Point Lighting
More informationInstructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationDesign, testing, certification, installation & maintenance
Legislation, Standards and Technology Design, testing, certification, installation & maintenance of electrical equipment in hazardous locations in India by Wolfgang Berner, Ashwini Bondale and Manikandan
More informationEX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
More informationIntroduction for Photovoltaic Power System Test in China. Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov.
Introduction for Photovoltaic Power System Test in China Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov. 6, 2012 Content Testing Status of PV power systems in China Test
More informationARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
More informationRAPPORTO DI PROVA TEST REPORT
RAPPORTO DI PROVA TEST REPORT Titolo (Title): DEGREES OF PROTECTION PROVIDED BY EMPTY ENCLOSURES (IP55 CODE) on UNIVERSAL RACK UR181110 Richiedente (Customer): - Ente/Società (Dept./Firm): C.E.P.I RACK
More informationHAZARDOUS AREA TECHNICAL GUIDE
Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,
More informationSafe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
More informationMETAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
More informationTechnical application guide IP codes in accordance with IEC 60529
www.osram.com Technical application guide IP codes in accordance with IEC 60529 What are IP codes? Depending on their potential exposure to foreign objects, electrical devices (e.g. luminaires, LED modules
More informationThe role of manufacturer s in the quality of PV products
ENERGÍA SOLAR TÉRMICA Y FOTOVOLTAICA: MÓDULOS, PANELES Y COMPONENTES PRINCIPALES The role of manufacturer s in the quality of PV products Aarón Sánchez Juárez ANES Vicepresidente Researcher at: Renewable
More informationCSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version)
CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version) ADD.:No.123, Focheng West Road, Jiangning Development Zone, Nanjing, China Code: 211100 TEL. : +86-25-52766666-6530/6728 FAX:
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
More informationGENERAL INSTALLATION MANUAL FOR EGING PV MODULES
GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationWhite Paper IK code: Impact protection in line with the IEC 62 262 standard. By Sven Schnautz
White Paper IK code: Impact protection in line with the IEC 62 262 standard By Sven Schnautz Contents List of images... 3 List of tables... 3 List of figures... 3 Introduction... 4 Basic principles...
More informationSafety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationAnnex of the certificate (Page 1/6) Accreditation Scope
As a Testing Laboratory Annex of the certificate (Page 1/6) Accreditation Scope Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli 35681 İZMİR / TÜRKİYE Phone : 0 232 376 24 25 Fax : 0 232 386 33 98 E-Mail
More informationFire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
More informationDNVGL-CP-0393 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0393 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationCable Trays and Ducts (Metallic)
p pproval roramms for U rcos orasato Mutual coto (M)No. 2.9 STANDARD FOR CERTIFICATION Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-P009 Cable
More information5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment
Two Documents are used for the Classification of Combustible Dusts and Hazardous Locations: NFPA 499-Recommended Practices for the Classification of Combustible Dusts and Hazardous Locations for Electrical
More informationNew Cable Tie Type Classifications
1 New Cable Tie Type Classifications UL 62275 United States CSA C22.2 No. 62275 Canada NMX-J-623-ANCE Mexico Technically Equivalent to IEC 62275 All cable ties are not created equal!!! With an increasing
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationInstallation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
More informationENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
More informationCONSULTING Training Courses
CONSULTING Training Courses 2 EXPLOLABS TRAINING MAKES THE DIFFERENCE 1. GENERAL Why training by Explolabs Consulting? For training in the specialized, high-risk field of explosion protection, one needs
More informationThe easy way to build switchgear and controlgear assemblies in compliance with the regulations
The easy way to build switchgear and controlgear assemblies in compliance with the regulations A guide for partially type-tested switchgear and controlgear assemblies in compliance with EN 60 439 What
More informationHazardous location. Definitions
Hazardous location Definitions hazardous location means any location, where there may be a significant risk of igniting gas, dust, mist or vapour, including the following: 1.1 For underground coal mines
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationExplosion Protected Electrical Apparatus in the Russian Federation
Legislation, Standards and Technology Explosion Protected Electrical Apparatus in the Russian Federation Adaptations of National Standards to International Standards, deviations and peculiarities by Vitaly
More informationTHERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K]
More information(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
More informationAttachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
More informationInstallation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
More informationLV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
More informationIndustrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports
APPLICATION TYPE TEST Industrial Process Plants ANT-V: Reliable, safety switchgear Hundreds of ANT s Switchboards have been supplied to industrial factories. ANT-V siwtchboards are designed, fabricated
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61892-1 First edition 2001-12 Mobile and fixed offshore units Electrical installations Part 1: General requirements and conditions Unités fixes et mobiles en mer Installations
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
More informationSolar Cell Bypass Diodes in Silicon Crystalline Photovoltaic Panels
VISHAY GENERAL SEMICONDUCTOR www.vishay.com Rectifiers IMPORTANT CHARACTERISTICS OF BYPASS DIODES FOR PHOTOVOLTAIC SOLAR CELLS 1. Forward Voltage Drop (V F ) at Bypass The basic function of bypass diodes
More informationIntegration of a 400W ac dc power supply into a closed system relying only on natural convection cooling
Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling How potting an electronic assembly simplifies the thermal management in harsh working conditions
More informationCOMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR
COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR Copyright Material IEEE Paper No. PCIC 2003-13 Eddie Wilkie Eaton Cutler-Hammer 3990 Old Tasso Road NE Cleveland, TN 37312 USA Abstract
More informationHow To Protect An Explosion
The basics of explosion protection preface It is a fact that gases, vapours and mists escape during the production, processing, transportation and storage of flammable substances in the chemical and petrochemical
More informationCourse Title: Safety Issues in Electronics Engineering Technology Number of Credits: 3 B.A. B.S. B.A.S A.A. A.S. Degree Type
GENERAL INFORMATION Name: Diane King Phone #: 77021 Course Prefix/Number: ETI3704 Course Title: Safety Issues in Electronics Engineering Technology Number of Credits: 3 B.A. B.S. B.A.S A.A. A.S. Degree
More informationYour Sharp system will be supplied with one of the following sets of panels:
Sharp3000 3kW Solar System Panel Specifications Your Sharp system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum 3000
More informationO&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules
403 Hitachi Review Vol. 63 (2014), No. 7 Featured Articles O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules Tohru Kohno Tetsuharu Ohya Tomoharu Nakamura OVERVIEW:
More informationTHERMAL ENERGY METER MC 108/ET
USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta
More informationSession 12 Ex Protection Concepts
Session 12 Ex Protection Concepts Ex Protection Concepts Electrical Electrical Symbol Typical Typical Zones IEC Standard Basic concept of protection IEC EPL Increased safety e Gb 1,2 IEC 60079-7 No arcs,
More informationHigh Surge Axial Cemented Wirewound Resistors
High Surge Axial Cemented Wirewound Resistors FEATURES High voltage surge (up to 12 kv) withstanding capability Non flammable silicon cement coating High grade ceramic core Material categorization: for
More informationISO/IEC 17025 Environmental Test Laboratory
ISO/IEC 17025 Environmental Test Laboratory Fast and reliable IEC qualified assessment laboratory for electronic components (IECQ) Environmental testing, consisting of the complete range of mechanical,
More informationLEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells
Engineering Production Sales LEAD CRYSTAL Valve-regulated lead-crystal batteries Energy storage Cells User Manual www.axcom-battery-technology.de info@.axcom-battery-technology.de Chapter 1: 1. Introduction
More informationIP Rating Chart. 910 East Orangefair Lane Anaheim, CA 92801 USA. www.anaheimautomation.com 714-992-6990 714-992-0471, Fax
IP, NEMA and UL Rating Codes The International Protection Rating, sometimes referred to as an Ingress Protection rating, is a set of codes used to define specific levels of protection. These codes consist
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationIR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com. ID 4016 Rev A
IR WINDOW CERTIFICATION GUIDEBOOK Copyright CorDEX Instruments Ltd. www.irwindows.com training@cord ex.com ID 4016 Rev A Content 1. General... Page 3 2. Introduction... Page 4 3. UL Underwriters Laboratories...
More informationRosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More information