Safety instructions VEGADIS DIS81.CEIA/V****
|
|
|
- Corey Kelley
- 10 years ago
- Views:
Transcription
1 Safety instructions VEGADIS DIS81.CEIA/V**** CSA Ex d IIC T6 T1 Gb 0044 Document ID: 48926
2 Contents 1 Area of applicability General information Technical data Application conditions Protection against static electricity Installation Grounding/Potential equalization Material resistance Ignition protection type flameproof enclosure Ex "d" Type and size of the threads of the "Ex-d" cable entries... 5 Please note: These safety instructions are part of the documentation: VEGADIS Certificate CSA VEGADIS DIS81.CEIA/V****
3 1 Area of applicability These safety instructions apply to the display and adjustment unit VEGADIS DIS81.CEIA/V**** according to the Certificate CSA (certificate number on the type label) and to all instruments with the number of the safety instruction (48926) on the type label. 2 General information The display and adjustment unit VEGADIS DIS81.CEIA/V**** with flame-proof encapsulation "Ex-d" is used for remote adjustment and visualization of measured values in conjunction with a VEGA radar sensor VEGAPULS, a guided radar sensor VEGAFLEX or a pressure transmitter VEGABAR with certified flame-proof encapsulation "d". The VEGADIS DIS81.CEIA/V**** and the radar sensors VEGAPULS, guided radar sensors VE- GAFLEX or pressure transmitters VEGABAR communicate with each other via a BUS signal, the I 2 C-BUS. The display and adjustment module PLICSCOM is integrated in the display and adjustment unit VEGADIS DIS81.CEIA/V****. The VEGADIS DIS81.CEIA/V**** is suitable for applications in hazardous atmospheres of all combustible materials of explosion group IIA, IIB and IIC, for applications requiring EPL-Gb instruments, as well as for installations in Class I, II and III Division 1 Hazardous Locations The atmospheres can also be combustible gases, mists, vapours, dusts, fibers and flyings. If the VEGADIS DIS81.CEIA/V**** is installed and operated in hazardous areas, the general Ex mounting instructions IEC , Canadion Electrical Code C /NFPA70 - NEC, and these safety instructions must be observed. The operating instructions as well as the installation regulations or standards that apply for explosion protection of electrical systems must always be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. 3 Technical data Electrical data BUS power supply and signal circuit: (terminals 5, 6, 7, 8) U 6,4 V DC Um = 253 V AC/DC Pi 500 mw For connection to a VEGA sensor VEGAPULS, VEGAF- LEX or VEGABAR with certified flame-proof encapsulation "d" The BUS supply and signal circuits are galvanically separated from parts that can be grounded. 4 Application conditions Max. permissible ambient temperatures depending on temperature classes. Temperature class T6 T C Permissible temperature on the electronics housing The application conditions during operation without explosive mixtures are mentioned in the operating instructions manuals. VEGADIS DIS81.CEIA/V**** 3
4 5 Protection against static electricity The VEGADIS DIS81.CEIA/V**** is provided with a caution label referring to the safety instructions in case of electrostatic charging during operation. Caution: Danger of electrostatic charging! Avoid friction No dry cleaning Do not mount in areas with flowing, non-conductive products 6 Installation The BUS supply and signal circuit between the VEGADIS DIS81.CEIA/V**** and a VEGA sensor VEGAPULS, VEGAFLEX or VEGABAR with certified flame-proof encapsulation "d" must be installed ungrounded. The required isolation voltage is > 500 V AC. 7 Grounding/Potential equalization The "Ex-d" housing must be grounded. The external or internal ground connection terminal on the housing of VEGADIS DIS81.CEIA/V**** serves for this purpose. 8 Material resistance The VEGADIS DIS81.CEIA/V**** must only be used in media against which the materials of the wetted parts are sufficiently resistant. 9 Ignition protection type flameproof enclosure Ex "d" The terminals for connecting to the operating voltage, i.e. signal circuits, are integrated in the connection compartment according to protection type flame-proof enclosure "d". The gaps between housing and cover as well as between threaded fitting and container are ignitionproof gaps. The "Ex-d" connection compartment is provided with a M20 x 1.5 or ½-14 NPT thread for connection to a certified "Conduit" system or for mounting a "Ex-d" cable entry certified according to IEC Cable entries of simple construction may not be used. Please take note of section 13.1 and 13.2 of IEC When connecting to a "Conduit" system, the associated sealing facility must be located directly on the "Ex-d" connection compartment. A certified "Ex-d" cable gland is automatically supplied with the delivery. It is suitable for insertion of armoured or unarmoured cables depending on the ordered version. The instructions in the document accompanying the respective cable gland must be observed. The "Ex-d" cable gland must be screwed tightly into the housing. The supplied cable gland is suitable for the housing temperature range mentioned in the VEGADIS DIS81.CEIA/V**** specification. If a different cable gland is used, the separately certified cable gland or the temperature classes on the electronics determines the maximum permissible ambient temperature on the housing. Before opening the lid of the "Ex-d" connection compartment or in case it is already open (e. g. during connection or service work), make sure that either the supply cable is completely voltage free or no explosive atmosphere is present. When wiring the connection line to the "Ex-d" connection compartment, it must be sufficiently 4 VEGADIS DIS81.CEIA/V****
5 secured against damage and in conformity with IEC The connection cables, the cable entries and the plugs or the pipeline sealing facilities must be suitable for the lowest ambient temperature. The cover of the "Ex-d" connection compartment must be screwed in completely before commissioning and secured by screwing out the lid locking screw all the way to the stop. Unused openings must be sealed according to IEC paragraph The blind plug mounted at the factory (regardless of the type ordered) is certified as part of the "Exd" housing. If a closing screw other than the premounted one or the screw with article number is used, a suitable one certified according to IEC must be used. Aluminium/Stainless steel "Ex-d" housing "Ex-i" connection compartment with electronics module 2 Type of thread 3 Threaded mounting socket 4 External ground terminal 5 Blind plug, part of the "Ex-d" housing 6 Cover catch 7 Inspection window of glass 10 Type and size of the threads of the "Ex-d" cable entries The "Ex-d" connection compartment of the VEGADIS DIS81.CEIA/VL/D**** has cable entries M20 x 1.5. VEGADIS DIS81.CEIA/V**** 5
6 The "Ex-d" connection compartment of the VEGADIS DIS81.CEIA/VP/D**** has cable entries ½-14 NPT. 6 VEGADIS DIS81.CEIA/V****
7 Notes VEGADIS DIS81.CEIA/V**** 7
8 Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2015 VEGA Grieshaber KG Am Hohenstein Schiltach Germany Phone Fax
Safety instructions VEGAPULS PSWL61. KX***H***
C US Safety instructions VEGAPULS PSWL61. KX***H*** CSA 14.2719243 CL I, DIV 2, GP ABCD; CL II, DIV 2, GP FG; CL III Document ID: 49581 Contents 1 Area of applicability... 3 2 General information... 3
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107
Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Operating Instructions Electronics module VEGADIF 65
Operating Instructions Electronics module VEGADIF 65 Document ID: 36132 Differential pressure Contents Contents 1 About this document 1.1 Function.................................. 3 1.2 Target group..............................
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Software and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
Making sense of Intrinsic Safety and Intrinsically Safe Tools
Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
Wolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
Electrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Design of intrinsically safe systems
AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Flameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
PLICSMOBILE: Measurement data via the mobile network
PLICSMOBILE: Measurement data via the mobile network Data using the mobile network simple and reliable The need for wireless signal transmission technologies increases as the wish for flexibility grows
CMP PRODUCTS. Ex d / Ex e / Ex nr CABLE GLANDS AND CONNECTORS. Triple Certified. www.cmp-products.com www.cmp-products.ru
www.cmp-products.com www.cmp-products.ru IECEx & ATEX 95 CMP PRODUCTS CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND C US Triple Certified Single Solution - Three Forms of Protection
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
Amphenol Cable Glands and Cord Grips 12-055-1. Amphenol
Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30
Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style
Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications
Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)
Explosion Proof. Explosion Proof
Explosion Proof Explosion Proof Table of Contents Lighting Fixtures...I Panels....II Sockets and Plugs.....III Motor Starters.....IV Fittings V Junction Box... VI CBLE GLND ND CBLE CONNECTION SPECILISTS
IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В.00224 Series RU No. 0067507
EAC CUSTOMS UNION CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В.00224 Series RU No. 0067507 CERTIFYING BODY Non-Profit Independent Research Organisation Certification Electrical Equipment,
CalMod Design-Build Electrification Services
SECTION 28 16 00 INTRUSION DETECTION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the detailed technical requirements for the Intrusion Detection System (IDS), where the Contractor
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
Products Solutions Services. CompEx training From the process safety experts
Products Solutions Services CompEx training From the process safety experts 1 CompEx Training The process safety experts Endress+Hauser is a global leader in measurement instrumentation, services and solutions
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Vigilant LED High Bay for Indoor and Outdoor Industrial Applications
for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
RAEGuard EC FGM-13XX
RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
CLASSIFICATION NOTES
CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification