D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases
D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization Smoke Detector, D8/D8TH Photoelectric Smoke Detectors, and D0/D0/D0 Heat Detectors. Install these bases according to the National Fire Alarm Code, NFPA 7. Before installing a smoke detector base, read and understand this and the following documents to ensure proper system operation: D8/D8TH Installation Instructions (P/N: 09) D8 Installation Instructions (P/N: 0) D0/D0/D0 Installation Instructions (P/N: 70) NFPA Standard 7 This document covers only the information necessary to mount and wire the bases. Other information is available from: Two-wire compatibility information in the Technical Service Note: Two-Wire Smoke Detector Compatibility (P/N: 8) Installation guidelines in the Technical Service Note: Smoke Detector Installation Considerations (P/N: 7) Information about power requirements, testing, and maintenance in the D8/D8TH Installation Instructions (PN: 09), D8 Installation Instructions (PN: 0), and D0/D0/D0 Installation Instructions (PN: 70). - D87 Base only, two-wire - D88 Base only, two-wire, wide diameter - D9 Base only, four-wire - D9A Base only, four-wire, Form C Auxiliary relay - D9E Base only for power supervision, fourwire, end-of-line (EOL) relay, Normally Open (N/O) auxiliary relay - D9S Base only, four-wire with sounder - D7 EOL supervision module for four-wire systems A is the Underwriters Laboratories, Inc. (UL) compatibility identifier for the D8, D8/D8TH, D0/D0/D0 Smoke Detectors. To determine the identifier used with the D87, refer to the Technical Service Note: Two-Wire Smoke Detector Compatibility (P/N: 8). Detector Power Requirements Standby Voltage: - Two-wire: 8. VDC to.0 VDC - Four-wire: 0 VDC to 0 VDC Alarm Current Two-wire: Dependent on the control panel that must limit the alarm current to 00 ma maximum Four-wire: - D9: ma at VDC; ma at VDC (70 ma maximum at 0 VDC) - D9A: 8 ma at VDC; ma at VDC (7 ma maximum at 0 VDC) - D9E: 8 ma at VDC; 8 ma at VDC (00 ma maximum at 0 VDC) - D9S: ma at VDC; ma at VDC; Sounder ma at VDC, ma at VDC Bosch Security Systems, Inc. /0 F0U0890-07
D87/D88/D9/D9A/D9E Installation Guide.0 Mounting..0 Mounting. Select mounting locations based on the Technical Service Note: Smoke Detector Installation Considerations (P/N: 7).. Pre-run all system wiring to the base locations.. Mount the base using the two oblong mounting holes.. Tighten the base to the mounting surface.. If mounting to in. (0 cm) square boxes, use the adapter plate. First, mount the adapter plate to the box, then mount the base to the adapter plate and box using the oblong mounting holes. Refer to Figure..0 Two-Wire Detector Wiring Refer to Figure and Table for the D87 and D88 terminal functions. Figure : ( ) (+) D87 Wired in a Two-Wire Configuration Figure : Adapter Plate Connections - Alarm loop negative (-) - Alarm loop positive (+) - End-of-line resistor Table : Two-Wire Terminal Functions Terminal Function Alarm loop positive (+) IN Alarm loop positive (+) OUT Remote LED output Alarm loop negative (-) No connection - Adapter plate mounting holes () - Base to adapter plate mounting holes ()- Depending on local regulations, the bases might be surface mounted using anchors, mollies, or wing nuts. The bases might also be directly mounted to in. (0 cm) octagonal electrical boxes or single gang switch boxes. Ensure the volume of any electrical box you use accommodates the number and size of conductors as specified by the National Electrical Code (NEC) or any local regulations having jurisdiction.. Review Section.0 Two-Wire Detector Wiring, and Section.0 Four-Wire Detector Wiring, page for wiring information. 7. Connect the wiring to the bases. Bosch Security Systems, Inc. /0 F0U0890-07
D87/D88/D9/D9A/D9E Installation Guide.0 Four-Wire Detector Wiring.0 Four-Wire Detector Wiring. Terminal Connections Do not twist wires or loop the wires around terminals. Cut, strip, and insert the In/Out wires as individual ends for terminal connection.. EOL Resistors Use the EOL resistors supplied or ones specified by the control panel manufacturer. This includes EOL resistors used with the D7 Module.. D7 Power Supervision Relay Refer to Figure for the D7 wiring. Figure : D7 Wiring. Terminal Functions Refer to Table and Figure through Figure for the D9 and D9A terminal functions. Table : Four-Wire Terminal Functions Terminal Function DC power (+) IN (No connection for D9E) DC power (+) OUT (DC power [+] IN for D9E) Remote LED output DC power negative (-) Alarm loop (N/O) Alarm loop (C) When operating the D9, D9A, or D9E in a VDC system, cut the yellow voltage jumpers on each base. (+) ( ) A C B D. D9 Refer to Figure for the D9 wiring. Figure : D9 Wired in a Four-Wire Configuration - Smoke power positive (+) - Smoke power negative (-) - Alarm loop - D7 EOL power supervision module - A = Red wire (+ V) - B = Yellow wire (+ V) (+) ( ) A C B D - C = Black wire (common) - D = Blue wires - End-of-line resistor When using the D7 with VDC systems, connect the red wire to Terminal on the last base in the run. The yellow wire remains unconnected. - Cut loop for VDC - Smoke power positive (+) - Smoke power negative (-) - Alarm loop - D7 EOL power supervision module - A = Red wire (+ V) When using the D7 with VDC systems, connect the yellow wire to Terminal on the last base in the run. The red wire remains unconnected. Use one D7 per loop with the D9 and D9A. - B = Yellow wire (+ V) - C = Black wire (common) - D = Blue wires - End-of-line resistor The D9 is the standard smoke detector base used in four-wire configurations. The Alarm Loop relay (Terminals and ) is a N/O relay rated at 0. A at 00 VDC. The relay closes on alarm. Bosch Security Systems, Inc. /0 F0U0890-07
. D87/D88/D9/D9A/D9E Installation Guide.0 Four-Wire Detector Wiring. D9A Refer to Figure for the D9A wiring..7 D9E Power Supervision Base Refer to Figure for the D9E wiring. Figure : D9 Auxiliary/Alarm Contact Wiring Figure : D9 Power Supervision Base N/C 9 C 8 - Form C auxiliary - N/O alarm N/O 7 The D9A provides a N/O Alarm Loop relay and an auxiliary set of Form C (NC/C/NO) contacts. The contacts are rated at 0. A at VAC and at.0 A at 0 VDC for resistive loads. Do not use the D9A with inductive or capacitive loads. ( ) (+) - Cut loop for VDC - Smoke power negative (-) - Smoke power positive (+) - N/O auxiliary contacts - Alarm loop - End-of-line resistor 9 8 7 The D9E provides a set of N/O alarm loop contacts and an auxiliary set of N/O contacts. The contacts are rated at 0. A at VAC, and at.0 A at 0 VDC for resistive loads. Do not use the D9E with inductive or capacitive loads. The D9E also provides EOL power supervision using a built-in relay. This eliminates the need for separate power supervision devices such as the D7. Only use one D9E base per zone run; it must be the last base on the run. The EOL relay is rated at 0. A at 00 VDC for resistive loads. Bosch Security Systems, Inc. /0 F0U0890-07
D87/D88/D9/D9A/D9E Installation Guide.0 Four-Wire Detector Wiring.8 Remote Alarm Indicator Using the SMK-RA Alarm Indicator, connect the positive (Item in Figure 7) lead to Terminal and the negative lead (Item in Figure 7) to Terminal. Figure 7: SMK-RA Remote Alarm Indicator Wiring - Red wire - SMK-RA Annunciator - Alarm indicator - White wire - Two-wire detector base Bosch Security Systems, Inc. /0 F0U0890-07
. D87/D88/D9/D9A/D9E Installation Guide Notes Notes Bosch Security Systems, Inc. /0 F0U0890-07 7
Bosch Security Systems, Inc. 0 Perinton Parkway Fairport, NY 0 USA www.boschsecurity.com Bosch Security Systems, Inc., 00