Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint



Similar documents
Data Center Power Distribution and Capacity Planning:

Measuring Power in your Data Center

Data Center Infrastructure Management: How to Optimize Data Center Operations

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

EO and Smart Federal Government Data Center Management

Re Engineering to a "Green" Data Center, with Measurable ROI

Power Management. Raritan Description.

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Server Technology, Inc.

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

Office of the Government Chief Information Officer. Green Data Centre Practices

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

How To Improve Energy Efficiency In A Data Center

EO and Smart Federal Government Data Center Management

Specialty Environment Design Mission Critical Facilities

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Data Center Leadership In the DOE Better Buildings Challenge

Managing Data Centre Heat Issues

dctrack Data Center Infrastructure Management Visualize, Manage and Track IT and Facilities Systems dctrack

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

General Recommendations for a Federal Data Center Energy Management Dashboard Display

Measure Server delta- T using AUDIT- BUDDY

5 Reasons. Environment Sensors are used in all Modern Data Centers

Energy Efficient High-tech Buildings

Data Center Infrastructure Management: ERP for the Data Center Manager

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Recommendations for Measuring and Reporting Overall Data Center Efficiency

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Data Center Energy Use, Metrics and Rating Systems

CenterMind P+ Solution for efficient power management

Data Centers: Definitions, Concepts and Concerns

Reducing Data Center Energy Consumption

Data Center Infrastructure Management (DCIM) Demystified

Environmental Data Center Management and Monitoring

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

Data Center Technology: Physical Infrastructure

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M

Energy Management Services

Data center upgrade proposal. (phase one)

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Harmonizing Global Metrics for Data Center Energy Efficiency

Improving Data Centers Energy Reliability & Efficiency. December 2015

Managing Cooling Capacity & Redundancy In Data Centers Today

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

ICT and the Green Data Centre

Metrics for Data Centre Efficiency

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Mejora la Eficiencia Operativa en Centros de Datos

Management and Wireless in the Data Center

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Zen Internet Case Study

DATA CENTER ASSESSMENT SERVICES

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

Green Computing: Datacentres

Best Practices. for the EU Code of Conduct on Data Centres. Version First Release Release Public

Data center lifecycle and energy efficiency

Green Data Centre Design

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

EU Code of Conduct for Data Centre Efficiency

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Data Centre Infrastructure Assessment

The necessary convergence of IT and Facilities

Includes customer case study. February 28, 2013

Server Technology, Inc.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Australian Government Data Centre Strategy

Cheat Sheets to Data Center Infrastructure Management

Legacy Data Centres Upgrading the cooling capabilities What are the options?

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

Direct Fresh Air Free Cooling of Data Centres

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

Intelligent Power Distribution in the Data Center

Transcription:

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment 50% Source: EYP Mission Critical Facilities Inc., New York Source: EPA Lawrence Berkeley National Laboratory study on data center power allocation: 46 percent used by IT equipment such as servers 23 percent used by HVAC cooling equipment 8 percent by HVAC fans 8 percent by uninterruptible power supply (UPS) equipment losses 4 percent by lighting 11 percent other uses, e.g., misc. electrical losses, support office area, etc. 2

Metrics: PUE, DCiE, and Carbon Footprint PUE = Total Facility Power IT Equipment Power DCiE = IT Equipment Power Total Facility Power x 100% Carbon Emissions (kg) = Source: EYP Mission Critical Facilities Inc., New York Energy (kwh) * Carbon Factor (kg/kwh) Assumptions: 10Mw total, 5 Mw IT, 0.08/kwh, 7x24 operation PUE = 10 Mw/5 Mw = 2.0, DCiE = 50% 8760 hours x 0.08/kwh x 10 Mw = 6.9M annual cost of power Example Carbon Factors: Gas G = 0.19 kg/kwh Coal G = 0.35 kg/kwh CO2 = 8760 hours x 10 Mw x.35 kg/kwh CO2 = 30,660,000 kg (about 6759* cars) *based on ~12k miles and ~4536kg 3

Why measure? Because you can t manage what you don t measure How do you know your Data Center PUE? Will you be able to comply to to CRC or ASHRAE future guidelines? How do you know how close you are to tripping a breaker? How do you know if you have the power capacity for more IT equipment? How do you know whether you re over cooling or have hotspots? How do you know the impact of any change? 4

The Two Paths to increased power efficiency? Optimizing IT equipment Virtualization decommission servers extra savings on cooling power save mode consolidation upgrade technology batch processing during offpeak Control Test and Dev Servers Optimizing Infrastructure avoid overcooling minimize humidification reduce air mixing via hot/cold air separation blanking plates to minimize recirculation raised floor grommets to reduce bypass airflow optimize floor layout (CFD) closely couple supply and returns to the load 5

What do you measure? Measurements for Optimising IT equipment Actual IT Load IT Device Department Application IT Utilisation CPU cycles/power usage Actual Business Benefit Department Allocation Measurements for Optimizing Infrastructure Branch Circuit Monitoring Room Temperature Rack Temperature PuE Airflow Humidity 6

Where to measure power 7 Uptime Institute, 4 Metrics That Define Data Center Greenness

Where to measure temperature Source: ASHRAE, Thermal Guidelines for Data Processing Environments 8

What to look for in a solution Accuracy Real measured data vs. assumptions-based calculations, e.g., kwh Metering optimized for real-world conditions vs. lab Sine wave vs. wave with harmonic distortion Depth of data Just current vs. watts, power factor, voltage Building or UPS level vs. individual outlets and IT devices Open, interoperable with other systems Data is portable via standard protocols Easy to deploy, maintain, use Considerations for monitoring both power and temperature Software to collect, trend, report data Sampling/polling frequency Measurement period Forward looking considerations, e.g., CO2 footprint, bill back 9

What to do with the data gathered? Measure PUE and compare DC efficiency against peers Find stranded power and optimize existing power capacity vs. nameplate Temperature Deltas Increase room temperature to reduce electricity costs Bill-back by metering kwh to drive behavior Monitor carbon footprint, prepare for carbon trading Improve manageability of DC, and make smarter decisions 10

The roadmap to your PUE IT equipment power measurement from Total facility power measurement from Minimum measurement interval Level 1 Basic Level 2 Intermediate Level 3 Advanced UPS PDU Server Data center input power Data center input less shared HVAC Data center input less shared HVAC plus building, lighting, security Monthly/weekly Daily Continuous Source: greengrid.org 11

Intelligent rack PDUs new options to measure at the rack for Infrastructure and IT Optimization What can be done with latest intelligent rack power strips? Outlet-level metering to measure device PDU-level metering to measure circuit Temp/Humidity sensors to measure rack environment Thresholds, alerting and notifications Trending and reporting over time Remote switching via IP Standards-based protocols offer easy integration to existing systems Secure Integration with IT Management Systems 12

Raritan s project Benefits of Granular Power Measurement in a typical small size company data center Aim: Implement full measurement systems to improve efficiency Location: Raritan Production Data Center New Jersey Process steps Establish baseline Survey nameplate data and take point measurements for all 68 servers First CFD run for baseline Deploy real-time power data collection tools to replace nameplate data. Dominion PX rack PDU: measure and record instantaneous, max, min and avg power for each IT device Measure the branch circuit level power for all infrastructure Deploy temperature sensors 2 per rack 1 for data center room and outside Intake and output of each CRAC Deploy data collection system Raritan Power IQ management software data collection Analyze measured data Conclusions published in Raritan s white paper Power Moves Take action to improve efficiencies and continue to monitor 13

What we found Calculating Raritan s PUE 71% of the total average power consumption was used for critical IT equipment 55 percent for servers alone 29% for support services like cooling and lighting Total Power = Support Infrastructure (5.625 kw) + Critical Load (13.68 kw) = 19.3 kw Raritan PUE = 1.4 DCiE= 71%( 1/PUE) 14

What we found..nameplate vs. Actual Power Draw Actual consumption much lower than nameplate Consumption varies widely by device/application Average consumption for all devices 39% of nameplate Average max consumption for all devices 48% of nameplate Room for optimization on low end for improving efficiency High end allows room for improving reliability Opportunity to Improve Efficiency Opportunity to Improve Reliability Source: Raritan data center, Feb 2008 15

Analysis and lessons The spread between nameplate and actual emphasizes the need to measure and not wholly rely on de-rated averages. We now understand our power use patterns over time day/month and ultimately season Our PUE was better than we dared assume = 1.4 = 19.3KW/13.7KW? Small business sweating the assets cooling not over engineered! Smaller Rooms engineered to fit limited expansion planned for We don t need to add more servers! Found 45 low utilized or idle devices for possible consolidation/vm We can improve utilization of existing power Average load of all equipment was 38% vs. nameplate We found 8 devices running above 80% of nameplate which we should investigate to improve reliability and reduce risk We had a baseline from which to compare and optimize 16

Actions Taken Increased computer room thermostat temperature from 20 C to 23 C. Implemented a virtualization project. Removed 7 servers from the IT environment (7 of 68) Participation in the U.S. Environmental Protection Agency (EPA) ENERGY STAR study by providing our data on a monthly basis. Achieved an 8% saving in total power The Green Grid is assisting the U.S. Environmental Protection Agency (EPA) in developing an ENERGY STAR rating for data center infrastructure. The EPA is collecting data on energy use and operating characteristics from a large number of existing data centers, including both stand-alone facilities and those located in offices and other building types. The collection of sufficient data from data center operators is critical to the development of an ENERGY STAR rating for data center infrastructure. 17

Do we stop here? We have understood our use of cooling is relatively efficient and have granular measures and notifications in place that would allow us to increase operating temperature further if we wanted We have accurate data collection to properly assess replacement free cooling options and fully understand payback We are collecting highly granular data on our 61 remaining devices/platforms regarding power used vs. utilisation. We understand the platforms that have poor @ idle power performance and will move to replace with better performers with clear ROI at the appropriate time.

Thank You