Mounting and operating instructions. Surface-mounted hands-free feature home station 1250..



Similar documents
Operating Instructions. Keypad

Mounting and Operating Instructions. TV gateway

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

How To Use A Power Supply On A Powerline 2.2 (Ai)

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

Residual current socket 30mA Order No.:

Four-Line Small Business System Speakerphone 945

Digital Keypad Use s Manual

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

SECTION 3A (Rev.F) SECTION CONTENTS. Download from Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

Operating Instructions. Room temperature controller

OPERATING INSTRUCTIONS

Total Protection Alarm System

for DNE-K07 Reference and Installation Manual

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

How To Program An Autodialer

Four-Line Intercom Speakerphone 955

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

INSTALLATION AND OPERATION MANUAL

Installation Instructions

Wireless Home Security System Product Manual (Model #80355)

Four-Line Intercom Speakerphone 944

Programming and Installation Instructions. Passed ISO international system ratification

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

Venture Multiline Communications System

WIRELESS HOME ALARM SYSTEM (WHA1)

2 WIRE video door entry system

Installation Instructions. Thermo Call TC3

Converse 320. Userfriendly Guide

I NTERFACE CABLE ADAPTER MODULE

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Product and functional description

Wind Sensor W-RS485 with RS485 Interface

INSTALLATION INSTRUCTIONS

Operating instructions. RCD flat 4-fold, 6-fold

Control Box Wiring For PRSstandard Tool

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

TS510 & TS500. Installation & User Guide. Compatible Equipment

INSTALLATION INSTRUCTIONS

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Enterprise Telephone. Model OPERATING INSTRUCTIONS

Bizfō n 680. Administrator's Guide

Operating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Dialog 4220 Lite/Dialog 4222 Office

Solid as a rock Soliroc

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Triac Printed Circuit Board Replacement

KNX R. Rain Sensor. Installation and Adjustment

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

How To Use A Cell Phone On A Cellphone On A Kx-Tvm Series 2 (Kx) (Kox-Tvp) ( Kx) Series 2.5 (Kuk) Series (Kq) Series 1

AD-01 Slave Auto Dialer. Owner s Manual

User Installation Guide

Enterphone Solo. User/Installation Manual Part No

FG MOISTURE MONITOR Installation & Operation Manual

How To Connect A Music Source To A Cartridge

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

PS 155 WIRELESS INTERCOM USER MANUAL

Automatic Telephone Dialer TD-101(W)

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

User Guide VERIZON WIRELESS HOME PHONE CONNECT

Auto Dialer. Manual E-921APQ E-921GPQ

HP UPS R1500 Generation 3

Model PBX 308 System Administration Guide

Four-Line Small Business System Speakerphone 945

Edition 4 26 March 97. Response 130 telephone and answering machine. User guide

Stove Guard Kit User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

CS55H HOME EDITION... WIRELESS HEADSET SYSTEM

SETTING UP YOUR 6000 SERIES TIME RECORDER

VIDEO DOOR PHONE SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

No Phone Line II-48 System

Troubleshoot your ADSL Router/Modem Setup

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

Installation Instructions. ThermoCall TC4. Entry/Advanced

B.IQ push-button with room temperature regulation and display OPERATING AND ASSEMBLY MANUAL

USER GUIDE. Cisco Small Business. SPA 303 IP Phone for 8x8 Virtual Office

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Wireless Home Security Alarm System AM 500

Enterprise Edge M7310 Quick Reference Guide

Personal Assistance System Owner's Guide

Installing Cisco TelePresence MX200 G2 - Wheel Base

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Four-Line Intercom Speakerphone 964

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Euroset Connections

Vista. Vista 150 User Guide

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Transcription:

Mounting and operating instructions Surface-mounted hands-free feature home station 1250..

Device description The surface-mounted hands-free feature home station is a prefabricated unit and is part of the Gira door communication system. 4 5 6 3 2 1 1. Mounting plate 2. Fixing holes for wall mounting 3. 2-gang cover frame without crossbar (frameless installation only possible with wall mounting) 4. Fixing holes for box mounting 5. Housing, top section 6. Operating buttons 3

Mounting Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician. You can mount the surface-mounted home station on a flush-mounted or hollow-wall box (only with cover frame) directly onto the wall or on a wall lighting connection box (with or without cover frame) Mounting with a cover frame is described in the following. Simply leave out the cover frame if mounting without a frame. Box mounting 1. Place the mounting plate and cover frame onto the flush-mounted box. 2. Fasten the base plate to the support ring of the flush-mounted box with two screws. Wall mounting 1. Strip the supply line up to the wall. 2. Select the mounting site so that the mounting plate is located centrally over the cable outlet and draw the drill holes. 3. Drill the two mounting holes and insert the plugs. 4. Fasten the base plate and cover frame to the wall with two screws. 4

Connection If you have fastened the mounting plate to the wall, the home station is connected as follows: 1. Connect the 2-wire bus to the BUS terminals and the cables of the floor call button at the ET terminals of the connector if necessary. 2. Push the connector onto the contacts of the device PCB on the back of the surfacemounted home station. Note polarity Ensure that the BUS and ET names match on the connector and PCB. 3. Now close the home station by placing the housing top section on the mounting plate and snapping it in. 5

Commissioning Once you have installed all of the devices (door and home stations, control device etc.), you can start up the door communication system. Commissioning is described in the system manual included with the control device. i Max. number of call buttons Note that up to 15 call buttons can be assigned to a surface-mounted home station. Removal Opening the device To open the home station, carefully press the lower snap clip upward vertically with a screwdriver. Pulling off plug terminal The label on the rear of the device specifies the direction for pulling off the plug terminal. 6

Operation Operating buttons The following functions are executed via the four operating buttons of the surface-mounted hands-free feature home station: Accepting a call The button flashes for 2 minutes for an incoming call. Briefly press the button to start intercom communication with the person at the door station. The button illuminates continuously during the call. i Maximum conversation time The maximum conversation time is 2 minutes. When this time expires, the conversation is automatically ended. Enforcement function If the background noises at the door station are so loud that automatic switching of the speech direction is not guaranteed, you can use the enforcement function at the home station. For this purpose, press and hold the button while speaking. While the button is being pressed, only the person at the home station can speak and be heard. To release the voice control to the door station, release the button again. 7

Ending the call To end the voice connection, briefly press the button. The illumination of the button goes out. Setting the speech volume The speech volume is changed to one of four levels during intercom communication. Press the button briefly to increase the speech volume during the call. There are four volume levels in total. The nexthighest volume is set with each button press. When the loudest level is reached, the next button press sets the quietest volume level. Opening the door Press the button. If several doors are present, the door opener whose door station made the door call is operated within 2 minutes. It switches to the main door 2 minutes after the start of the call or 30 seconds after the door call is ended. Switching light on (only in conjunction with a switching actuator) Press the button to switch the light (e.g. the outdoor or staircase illumination) on. 8

Setting the call tone volume The call tone volume is changed to one of four levels when no intercom communication is in effect. Press the button for approx. 3 seconds. There are four volume levels in total. The nexthighest volume is set with each button press (3 seconds). When the loudest level is reached, the next button press sets the quietest volume level. Deactivating/activating the call tone You can deactivate the call tone of the home station when there is no intercom communication. Briefly press the button to deactivate the call tone. The button illuminates continuously while the call tone is deactivated. Press the button briefly again to reactivate the call tone. The illumination of the button goes out. Only deactivate the call tone if necessary Deactivate the call tone in special cases only. Otherwise, you run the risk of not hearing the ringing in an emergency, for example. 9

Setting the call tone melody The surface-mounted hands-free feature home station offers five call tone melodies, which can be individually assigned to the floor call button, the call buttons of the door station or the internal call buttons of other home stations. This allows, for example, a different door station call button with an individual call tone melody to be assigned to each person (e.g. parents, children) in a household with several people. The call tone melody is set as follows: 1. Trigger the call tone whose melody you would like to change by pressing the corresponding call button which was previously taught in. 2. To change the melody of the last triggered call tone, press and hold the button on the home station. 3. Then press and hold the button within 3 seconds as well until the new call tone melody is heard. 4. To select the next call tone melody, repeat Steps 2 and 3. Each time the and buttons are pressed, a new call tone melody is set. When the last call tone melody is reached, the next button press starts over at the first melody. i Note When deleting a call button assignment to a home station, the relevant call tone melody is reset to the factory setting. 10

Acceptance of guarantee The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/ installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 11

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Postfach 1220 42461 Radevormwald Deutschland Tel +49 (0) 21 95 / 602-0 Fax +49 (0) 21 95 / 602-191 www.gira.de info@gira.de 19/11