RFI Questions. Reference (Sect/Para/Pag e) QUESTION GOVERNMENT RESPONSE 1 RFP and Drawings



Similar documents
MEMORANDUM. General: Foundation:

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No December 2014

Saxe Middle School Auditorium Renovation February 4, 2015

THIS ADDENDUM MUST BE ACKNOWLEDGED. THIS ADDENDUM SHALL BECOME A PART OF THIS SOLICITATION. Amend Invitation to Bid 14-MC-2194 as follows:

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO.

OGS LIMITED ASBESTOS & LEAD SURVEY REPORT

How To Repair A House

Asbestos Abatement Work Plan for the Carter Carburetor Superfund Site

Fire Damage Repairs, 2510 Burton Street

NECESSITY OF SCHOOL CONSTRUCTION STAGE III DESIGN REVIEWS

DIVISION 248 ASBESTOS REQUIREMENTS. Asbestos Emission Standards and Procedural Requirements Asbestos Abatement Project Exemptions

CAPITAL PROJECTS DEPARTMENT MONTHLY ACTIVITY REPORT. January Project Management Division

Lee, Here are the questions from bidders received between August 17, 2015 and August 24, 2015 followed by our responses.

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

ASBESTOS AWARENESS PLAN

North Carolina State University. Asbestos Management Plan

Asbestos Management Program

Estimated Cost of Repair

Rehab Inspection Report Page 1

Bid Tabulation for IFB #9708 (Asbestos and Mold Abatement Services)

Vendor Selection Overview UNIT PRICES FOR ASBESTOS ABATEMENT & DISPOSAL SERVICES VARIOUS SITES

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNER

LIVING WITH FIBRO JUNE 1998 WORKCOVER NSW HEALTH AND SAFETY NOTES. WorkCover. Watching out for you.

Renovations for a New 18 Bed Gero-Psych Nursing Unit August 7, 2014 Lower Bucks Hospital Second Floor 501 Bath Road, Bristol, PA Addendum No.

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Asbestos Survey Form (See Instructions)

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

NATIONAL INSTITUTE OF BIOLOGICALS

Approved by: UBC ACT Committee

Hartsfield-Jackson Atlanta International Airport s

Supplemental Investigation Summary Report

SECTION ASBESTOS ABATEMENT

The Charter School Law establishes the following for charter schools with respect to school construction:

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

HATFIELD TOWNSHIP DRY CLEANING PLANT PERMIT APPLICATION PROCEDURES

Asbestos in your home

Asbestos Procedures. Asbestos Products

REQUEST FOR PROPOSAL # PROFESSIONAL SERVICES Environmental Engineering Services September 25, 2015

Basement & Foundation Damage

Washington University Asbestos Operations and Maintenance Plan

Vision Home Inspection

Facts about Asbestos. Council policy

Triarch Products Over Various Interior Substrates

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Asbestos in Your Home

ASBESTOS IN THE HOME

Inspection Item COMMENTS

ADDENDUM NO. 2. DATE: September 14, 2015 INVITATION FOR BID: IFB J Fire Station #22 Roof Replacement Project DATED: August 25, 2015

Architectural Engineering & Construction Management Proposal

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

ASBESTOS ABATEMENT GROUND FLOOR H SF SF SF 055A 111 SF 051C 336 SF SF 051A 116 SF SF 051B 47 SF 051D 91 SF

STICKLEY AUDITORIUM RENOVATION Community and Stakeholder Presentation

ADDENDUM #1. Can you add the material list per EA or LF, as listed on pages 52 and 53, to the pricing submittal form?

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

PRE-PURCHASE INSPECTION REPORT

Request for Proposal

PROJECT COST ESTIMATES & FEASIBILITIES

Phased Building Information Management (BIM) and Modeling Implementation Plan. David J. Gutierrez, AIA September, 2014

ADDENDUM 5 TO IFB 5212-BC UNLV UCC DORMITORY COMPLEX HUGHES AND FAIMAN HALLS HVAC AND ROOFING REPLACEMENT. University of Nevada, Las Vegas

Click to edit Master title style Maricopa County Asbestos NESHAP Overview. Valerie Brodeur Asbestos NESHAP Inspector

Asbestos is found naturally in rock formations around the world. It is made up of lots of small fibres.

ASBESTOS MANAGEMENT PROGRAM

Asbestos & Lead Program Update Project Managers Toolbox

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

Regulated Building Materials in Property Management. July 30, 2013

Preventing Ice Dams on Roofs

Asbestos Awareness Training; Protecting Both Adjusters and Insureds

HATFIELD TOWNSHIP. FLAMMABLE and COMBUSTIBLE LIQUIDS PERMIT APPLICATION PROCEDURES

Management of Asbestos. Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

CITY OF CHICAGO DEPARTMENT OF ENVIRONMENT. CONSTRUCTION or DEMOLITION SITE WASTE RECYCLING RULES AND REGULATIONS

C P W R. Research & Training

Building Code Clarifications - 7. Fire Resistance

Repair Project for April 7, 2009

CITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES

The Richard Stockton University ASBESTOS MANAGEMENT PLAN

G. Common Defects in Buildings - Leakage

NDSU TABLE OF CONTENTS

HOUSTON ELEMENTARY SCHOOL

Asbestos NESHAP ISSUES AND QUESTIONS

RFP VOICE OVER IP PHONE SYSTEM BID: # BOE

Attachment 5 Electrical Engineering

USES and CONCERNS. County of Santa Clara Safety Coordinator Forum

Georgia State University. Urban Life Building Roof Replacement

Defining who is responsible for items and areas in a Strata Scheme

Estimator: Miami Estimates Business: (305) Date Entered: 04/30/2008

ADDENDUM #2 November 4, 2015 IFB

Asbestos Survey Report

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

UNVERSITY HIGH SCHOOL U W. Gregory St. Normal, IL School Asbestos Management Plan. Supplemental.

Administrative Procedure. Asbestos

LEGAL REVIEW & UPDATE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CITY OF PLANO BUILDING INSPECTION FEE SCHEDULE. Initial Deposit/Fees are due at the time of the submittals. Effective 03/01/10

THE MINISTRY OF ENVIRONMENTAL PROTECTION, PHYSICAL PLANNING AND CONSTRUCTION


BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

DRAPER ELEMENTARY SCHOOL

Transcription:

PRE PROPOSAL INQUIRY FORM Government Reponse Project Title: NAVFAC - Paint and Repair Building 110 date: 8/23/12 SOLICITATION NO.: #2703893 RFI Questions Question No. Reference (Sect/Para/Pag e) QUESTION GOVERNMENT RESPONSE 1 RFP and Drawings The RFP references that this is a Design-Build project, however detailed plans including quantities have been provided. Please clarify the design intent on the project. eyes. There may be more. 2 Enclosure 3, Page 3 Factor 2, Item 2 requires a narrative describing the integration of construction within the existing building, keeping the building in full operation and coordinating the construction with overall building operations. General Note E on the plans, Sheet 1 of 5 indicates that the first floor and balcony will not be occupied during construction. Please clarify the occupancy of the building during construction and provide additional information of any building activities that will need to be coordinated during construction (if any). We expect to close operations during the project. However, since closing has a major negative impact on MWR profits the construction timeframe is 1 Dec. 2012 to 3 Jan 2013. The shorter timeframe the better.

3 Asbestos Survey and Small Project Part 3 The contract documents include an asbestos survey with quantities. Then Part 3, F2020 of the contract documents indicates Contractor is to bid per square foot of asbestos containing ceiling or wall material for asbestos abatement. Then it further goes on to say Contractor will include in his bid $10,000.00 as reserve fund for asbestos abatement. Are we only to carry the $10,000.00 for asbestos abatement in our bid? If not please provide more information as to the expectations/requirements for the asbestos abatement work on our end? Asbestos survey is done in 2003. This survey is for reference only. Contractor will do his own HAZMAT survey to make sure asbestos and lead presence. 4 Drawings General Note H on the plans, Sheet 1 of 5 indicates we are to treat all painted surfaces as containing lead and we can dispose the lead as ordinary construction debris. Then the note right below that says lead shall be disposed of as lead waste. Please indicate which is correct? See Note H Last line- Abatement material shall be disposed of as lead waste in accordance with local, Federal, state and NSGL requirements. Part 3 page 16 line one: Contractor shall perform verification testing as required of additional HAZMAT material survey shall be performed 5 Drawings In addition to question 4 above please confirm that all painted surfaces are to be treated as containing lead. If not please provide more information as to the expectations/requirements for the lead abatement work on our end? See Note H Last line- Abatement material shall be disposed of as lead waste in accordance with local, Federal, state and NSGL requirements. Part 3 page 16 line one: Contractor shall perform verification testing as required of additional HAZMAT material survey shall be performed 6 Small Projects Part 3, C3010 of the contract documents indicates we are to repair 690 SF of CMU walls. Please provide more information as to the level of repair required? Are we replacing complete blocks of CMU or only patching? eyes. There may be more. (See specification Part 3 page 4 C3010.)

7 Small Projects 8 Small Projects Part 3, C3010 of the contract documents says Construct damaged 20 0 LF wall curb on South West wall 4 0 below ceiling. Please provide more information as to what is required by this note. Part 3, C3030 of the contract documents indicates Contractor is to repair Auditorium ceiling (3,160 SF). Then it indicates ceiling is light weight concrete on wire mesh. Please confirm we are to provide (3,160 SF) of concrete repair at the Auditorium ceiling? eyes. There may be more. eyes. There may be more. (See specification Part 3 page 4 C3010.) Ceiling base construction material is given for information only. General base repair for smooth surface to prepare for paint. Please inspect on the site visit. 9 Small Projects Part 3, C3030 of the contract documents indicates Contractor is to construct 200 SF broken ceiling surface. Please provide more information and detail as to what we are required to construct? Is this full depth concrete repair, eyes. There may be more. partial depth concrete repair? 10 Amendment 2, RFI 3 response Response to RFI #3 confirms we are to furnish a new hazardous material survey and report in our base bid. Please confirm all abatement and monitoring work required based on this new survey will be paid for out of the $10,000 HazMat Allowance. Confirmed

11 Amendment 2, RFI 6-9 responses Responses to RFI #6-9 indicates RFP provided quantities for Confirmed. Reminder that this quantitiy is for evaluation wall and ceiling repair are provided for information purposes and is a best guess. Final quantitiy may vary. purposes only, and alludes we are to "inspect with our bare eyes" the extent of the work required. This is an impossible task in a dimly lit auditorium with ceilings 50' above our heads. There is no way to quantify the extent of this work at bid time other than to throw money at it and make a guess. Please confirm quantities of repair work as indicated in the RFP should be used as a basis for our proposal. 12 Amendment 3, RFI 1 response Is this a design/build or bid/build solicitation? RFP Part 2A requires design deliverables, but per the site visit, the Navy is issuing color schemes in forthcoming Amendment. Per same RFP section, construction submittals are to be CQC approved except plaster patch, paint, and colors to be approved by DOR. If the Navy is DOR, there's nothing else to approve. Please clarify who is DOR, Navy or contractor? The Navy will submit a basic color scheme with some detail. The scheme will require design time working with the customer for detailed drawings. 13 RFP Part 3 C3010 Extent of wall paint scope near the stage was limited to vertical round columns and sides of stage. Per discussion at site visit, additional painting of existing plaster surround behind outer most layer of stage draperies at sides and overhead were to be painted as well. Please confirm. The rectangular support just behind the the round columns on the stage is to be painted. The painting is to extend as far as the existing painted surface and no farther.

14 Enclosure 3 - Factor 2 The Basis of Evaluation mentions complying with requirements for material specifications, recycling methods and goals, hazardous material disposal, etc. Is it intended for this Basis of Evaluation to be a part of Factor 1, Technical Solution rather than Factor 2 Project Schedule and Phasing? See revised evaluation factors dated 17 August 2012 15 Proposal Please advise if all (3) pages of the RFI issued in Amendment 2 shall be included along with the signed SF30 form in the price book or just page 3 of the RFI that includes the signature lines. Signed RFI response forms shall be submitted in full with the price proposal. Only the most current needs to be sent. 16 Per Walk - Thru What will be required by the GC in regards to the Stage Curtains? The curtains are not to be removed. Carefully pull back to allow access to the required surfaces. Secure until the paint is dry. If dusty prep work is required it may be wise to wrap them in plastic. 17 Per Walk - Thru It was mentioned at the walk - thru that the Lobby was not part of this contract. Please confirm. Confirmed 18 Part 3/Section C30 Base Scope of Work - RFP drawings denote specific locations and square footages for repairs and painting that do not appear to correlate to the specific square footages listed in Part 3/Section C30. Please confirm the base bid is to be based on the quantities specified in Section C30. Confirmed

19 Part 3/Section C3030 Ceiling Construction - During the site visit, it appeared the ceiling was cement plaster on wire mesh, but Part 3/Section C3030 indicates it is lightweight concrete on wire mesh. Please provide original building record drawing details and specification for the ceiling construction. Drawings provided on CD 20 Original Building Information - Please provide a complete set of the original building record drawings. Provided on CD 21 Fire Protection Engineer (FPE) As the project scope is limited to existing finish surface repairs and painting, please confirm the services of an FPE are not required for this project. It is the contractor's reponsibility to check the need of technical people. 22 Water Damage It appears some of the damaged surfaces may be the result of water from roof or pipe leaks. During the pre-proposal meeting it was indicated the roof had been recently replaced to resolve the source of the water damage, but water was seen dripping from the ceiling at the underside of the balcony. Please confirm all leaks will be repaired by others prior to the start of this project. The Roof was replaced FY11. If there are leaks they should be repaired prior to the start of construction. However, a check of the area can be done after award to confirm. The contractor is not responsible for leak repairs. 23 It appears that the existing paint is semi-gloss please confirm what the paint finish shall be desired? The recommended paint sheen will be noted in the submitted scheme which is expected to be complete by COB Friday 24 August. This could change before the final paint schedule is completed by the contractor.

24 Part 3/Section C30 Since the quantity given in Part 3/Section C30 in the base qty. is for evaluation purposes please revise the proposal sheet to add unit prices for plaster repair and painting. See revised pricing sheet dated 22 August 25 Part 3/Section C30 Part 3/Section C30 indicates repair auditorium ceiling 3,160 sf. Is the 200 sf in addition to the 3,160 sf? Ceiling SF is for reference only. I acknowledge receipt of these RFI responses Firm Name (printed) Name (signed)