LED IMPORTANT SAFETY INSTRUCTIONS



Similar documents
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

AMERBRITE UNDERWATER WHITE LED POOL LAMP

PGL5/6 - Parking Garage Luminaire Installation Instructions

SAFETY RECOMMENDATION

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Dehumidifier Users manual. For Models: DH45S DH65S

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

5800 Temperature Sensor Cable Assembly

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

aseries A13B Mini Bullet Camera User Manual

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

LED MOTION ACTIVATED FLOOD LIGHT

Portable Air Conditioner

Model 1756 Test Lead Kit

Read this document before using this product.

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

RayClic Connection System Installation Instructions

767 Diagnostic System

MIC-WKT and MIC-WKT-IR

AutoDome Easy II. VEZ Series. Mounting Manual

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

IMPORTANT SAFETY RULES TO FOLLOW

758 Heavy-duty Ratchet Guy Wire Cutter

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Features. High Brightness LED Light source

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Replace the Pump Tube Classic

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NV7210N NW3620N NW4820N

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Installation Instructions for Alarm Module Kit A043F059

INSTALLATION INSTRUCTIONS

Step 1. Item 6. Item 1

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

About the HotWire Slot Standalone Shelf

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Wiper Motor Marinco 2.5. Installation Instructions

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Safety, Operation and Maintenance Manual with Parts List

GENUINE PARTS INSTALLATION INSTRUCTIONS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

XL PREMIUM OIL COOLER KIT

LIEBERT VNSA Installation Sheet

3 WATT LED SPOTLIGHT Model No. SLM

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Operating instructions in the back. PD1020L

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

orlando OWNER S MANUAL

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

MCR1900 Media Converter 19-Slot Chassis

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

RayClic Connection System Installation Instructions

Installation and Operating Instructions (for chargers shown below)

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS


INSTALLATION GUIDE AND OWNER S MANUAL

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

UV100A Ultraviolet Air Treatment System

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

EasyNote TJ Series. Disassembly Manual

Ducoterra Radiant Heating Panel Installation Manual

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

LED Security Spotlight User Manual

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

GSM-EXT Cable Assembly Installation Guide

Single Day Alarm Clock with. Bluetooth and USB Play-through

PS6500 Storage Arrays Rack Mount Instructions

HP UPS R1500 Generation 3

ERGL OWNER S MANUAL Elevated Runway Guard Light (ERGL)

Small form factor bay converter and hard drive installation

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

SECURITY SYSTEM SMART SIREN KIT

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

Transcription:

LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the luminaire box and all luminaire labels. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician. Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and operation and any hazards involved. Regular luminaire maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING RISK OF ELECTRIC SHOCK Disconnect or turn off power before installation or servicing. Verify that supply voltage is correct by comparing it with the luminaire label information. Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL approved recognized wire connectors. WARNING RISK OF BURN Allow lamp/luminaire to cool before handling. Do not touch enclosure or light source. Follow all manufacturer s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. RISK OF INJURY Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. Avoid direct eye exposure to the light source while it is on. RISK OF FIRE Keep combustible and other materials that can burn, away from lamp/lens. Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

LED IMPORTANT SAFETY INSTRUCTIONS : RISK OF PRODUCT DAMAGE Never connect components under load. Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit. Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace around luminaire. Avoid covering LED luminaires with insulation, foam, or other material that will prevent convection or conduction cooling. Unless individual product specifications deem otherwise: Do not exceed luminaires maximum ambient temperature. Only use luminaire in its intended location. Electrostatic Discharge (ESD): ESD can damage LED luminaires. Personal grounding equipment must be worn during all installation or servicing of the unit. Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance. Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance. Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings. Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT Carandini Mark Architectural Lighting Antique Street Lamps Lighting Control & Design Holophane Peerless Hydrel ROAM RELOC Renaissance Lighting Tersen Sensor Switch Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 2011 Acuity Brands Lighting, Inc. All rights reserved. 12/01/11

HOLOPHANE Bantam 2000 Installation and Figure 1 Enclosed LED Low Bays Figure 2 Maintenance Manual PENDANT HOOK OR LOOP STANCHION WALL CEILING ENDURALUME PRISMATITE PRISMPACK PRISMALUME GR2224 1. INTRODUCTION 1.1 Product. A Light Emitting Diode (LED) luminaire - This luminaire utilizes an auto sensing, 120-277VAC, nominal, LED driver. - An externally accessed wiring chamber is provided to contain all field splices and to house optional luminaire fusing. - Alternative mounting methods include: o Pendant mount to a 3/4" NPT threaded conduit o Hook and Loop mounts (damp locations only) or Gasketed Hook mounts o Stanchion mount to 1 1/2" threaded or unthreaded pipe stanchion o Wall mount with a flange-mounted, surface wall box with 1" NPT conduit entries for surface-wiring side entry o Ceiling mount to a 4" square or octagonal box (suitable for damp locations only) - A wide variety of lighting distributions may be obtained by using the many interchangeable optical assemblies. o A Optic Enduralume 2418 Enclosed o B Optic Prismatite 4451 Long and Narrow o G Optic Prismatite 4455 Symmetric o K Optic Prismalume Enclosed 6585 Wide o L Optic Prismalume Enclosed 6586 Medium o U Optic Prismpack Enclosed 6585 Wide o Z Optic Prismpack Enclosed 6586 Medium o U Optic with ELB (Extra Low Brightness) Option Prismpack Enclosed 6586 Wide o Z Optic with ELB (Extra Low Brightness) Option Prismpack Enclosed 6586 Medium 1.2 Alternate Information Sources. Holophane Field Service Department P.O. Box 3004 Newark, OH 43058-3004 (740) 345-9631 2. INSTALLATION 2.1 Tools and Materials Required. TABLE 1 Installation of Tools and Materials Use Flat blade screwdriver Pendant set screw Pipe threads sealant sealing conduit threads 5/16 socket wrench Stanchion and wall mount screws 1/2" wrench Wall mount box Figure 3 GR275 GR2225 2.2 Luminaire Mounting 2.2.1 Disconnect power to luminaire location. 2.2.2 Provide and install a suitable mounting structure that supports the full weight of the luminaire in accordance with local codes. 2.2.2.1 Note that all optical assemblies provide symmetric lighting distributions, except one. The B Optic Prismatite 4451 Long and Narrow provides a non-symmetric lighting distribution and must be aligned, as noted. NOTE For the B Optic Prismatite 4451 Long and Narrow, the refractor has directional arrows in the bottom of the glass that indicate the direction of the main lighting beam. These arrows are aligned with the latches on the luminaire. Align the luminaire at installation to orient the non-symmetric lighting distribution. 2.2.4 For wet location installations, apply sealant to the conduit threads during installation. 2.2.5 Though not recommended, the optical assembly may be removed from the electrical assembly for ease of installation. 2.2.5.1 Dis-engage the two side latches. See Figure 2 or 4. 2.2.5.2 Remove the optic cable screw from the electrical assembly, and set aside the optic. 2.2.5.3 Reinstall the screw into the electrical assembly for use during re-assembly.

Unlatch the optical assembly slowly and lower it straight down to avoid damaging the LED COB Module. Détachez lentement l'ensemble optique et baissez-le à la verticale pour éviter d'endommager le module COB DEL. If the optical assembly is removed for installation, care must be taken when handling the LED COB Module. Do not hold, handle or touch the LED COB Module, especially the electrical leads and the center of the orange/yellow portion of the LEDs, as this can damage the LED COB Module, thereby shortening the life of the LEDs or making the luminaire immediately inoperable or shortly thereafter. Do not allow dirt or debris to accumulate on the LED COB Module as this can affect optical performance. See Figure 4. Si l'ensemble optique est retiré pour l'installation, manipulez le module COB DEL avec précaution. Ne tenez, manipulez ni touchez le module COB DEL, surtout les câbles électriques et le centre de la partie orange/jaune des DEL, car cela risque d'endommager le module COB DEL, réduisant ainsi la durée de vie des DEL ou rendant le luminaire inutilisable, directement ou peu de temps après. Ne laissez pas la saleté ou les débris s'accumuler sur le module COB DEL, car cela risque d'affecter la performance optique. Voir figure 4. Figure 4 2.2.4 Stanchion Arm Mount 2.2.4.1 Install the stanchion arm onto the stanchion pipe. Threaded 1 1/2" NPT or NPS (for wet location) or non-threaded pipe (for damp location) may be used. 2.2.4.2 Orient the arm as required for the application and tighten the set screws securely. (Set screw points should embed into the pipe.) 2.2.4.3 Pull the electrical supply wires through the stanchion pipe, arm and into the luminaire wiring chamber. 2.2.4.4 Make the appropriate supply wire connections as described for Pendant Mount, Section 2.2.2.6. 2.2.5 Wall Mount 2.2.5.1 Determine the required positions for the conduit entry in the wall mount box and attach the box to the mounting surface using four bolts (1/4 inch to 3/8 inch size, not provided with the luminaire). 2.2.5.2 Attach the conduit to the box (1" NPT). 2.2.5.3 Feed electrical supply wires to the box and then feed them through the wall arm and into the luminaire wiring chamber. 2.2.5.4 Bolt the arm to the box using the four bolts provided. Tighten bolts to between 90 and 110 IN-LBS. 2.2.5.5 Make the appropriate supply wire connections as described for Pendant Mount, Section 2.2.2.6. 2.2.6 Ceiling Mount 2.2.6.1 Attach the ceiling mount plate to electrical box using the two 8-32 screws provided. 2.2.6.2 Pull the electrical supply wires through the plate and into the luminaire wiring chamber. 2.2.6.3 Make the appropriate supply wire connections as described for Pendant Mount, Section 2.2.2.6. DO NOT HOLD, HANDLE OR TOUCH THIS AREA OF THE LED MODULE GR2256 2.3 Installing the Optical Assembly 2.3.1 Lifting the optical assembly straight up over the LED COB Module, position the optical assembly against the bottom of the electrical assembly, aligning the alignment tab on the electrical assembly with the notch on the optical assembly. See Figure 2. 2.3.2 Position the bail of each latch over its lug on the optical assembly and snap both latches closed. See Figure 5. 2.3.3 Remove the optic cable screw from the electrical assembly, insert it through the loop in the end of the optic cable and reinstall the screw into the electrical assembly. Figure 5 2.2.2 Pendant Mount 2.2.2.1 Remove the wiring chamber cover. 2.2.2.2 Back out the conduit set screw far enough to insure that it will not interfere with the conduit threads. 2.2.2.3 Thread the electrical assembly onto the 3/4" NPT pendant or fitting a minimum 4 3/4 turns. Then continue to tighten a minimum of one additional quarter turn and until the luminaire is aligned as necessary for aiming of optics or for appearance purposes. 2.2.2.4 Tighten the conduit set screw against the pendant or fitting. 2.2.2.5 Pull the electrical supply wires through the pendant and into the luminaire wiring chamber. 2.2.2.6 Make the appropriate supply wire connections to the luminaire wires in the wiring chamber and reinstall the wiring chamber cover, tightening both closure screws snugly to seal the chamber properly. GR276 2.2.3 Hook or Loop Mount 2.2.3.1 Hang the luminaire and make the appropriate connections to electrical cord.

3. MAINTENANCE 3.1 Disconnect electrical power to the luminaire location before maintaining, replacing or cleaning any part of the luminaire. If unlatching the optical assembly, lower it slowly and straight down to avoid damaging the LED COB Module. Pour détacher l'ensemble optique, baissez-le lentement à la verticale pour éviter d'endommager le module COB DEL. When the optical assembly is removed or replaced for maintenance, care must be taken when handling the LED COB Module. Do not hold, handle or touch the LED COB Module, especially the electrical leads and the center of the orange/yellow portion of the LEDs, as this can damage the LED COB Module, thereby shortening the life of the LEDs or making the luminaire immediately inoperable or shortly thereafter. Do not allow dirt or debris to accumulate on the LED COB Module as this can affect optical performance. Lorsque l'ensemble optique est retiré ou remplacé pour l'entretien, manipulez le module COB DEL avec précaution. Ne tenez, manipulez ni touchez le module COB DEL, surtout les câbles électriques et le centre de la partie orange/jaune des DEL, car cela risque d'endommager le module COB DEL, réduisant ainsi la durée de vie des DEL ou rendant le luminaire inutilisable, directement ou peu de temps après. Ne laissez pas la saleté ou les débris s'accumuler sur le module COB DEL, car cela risque d'affecter la performance optique. Contact your local holophane representative for holophane approved replacement parts. Communiquez avec votre représentant Holophane local pour commander des pièces de rechange approuvées par Holophane. 3.2 Cleaning 3.2.1 Visually inspect the assembly to verify that there are no broken or otherwise sharp edges that could cause injury during cleaning. Replace the optical assembly if any such damage has occurred. 3.2.2 Wipe off the exterior of the luminaire to remove any dirt or debris that could enter the luminaire while maintaining it. Water, a mild detergent, and a damp cloth may be used if necessary. Do not use high pressure water equipment to clean the luminaire as this may cause water ingress to the luminaire. N'utilisez pas des équipements à jet d'eau haute pression pour nettoyer le luminaire, car cela risque de causer des infiltrations d'eau dans le luminaire. Do not use an abrasive cleaner on optical surfaces; loss of optical performance may result. N'utilisez pas un nettoyant abrasif sur des surfaces optiques; cela risque d'entraîner une baisse des performances optiques. 3.3 LED COB Module Replacement, See Figure 6 3.3.1 Verify that power has been disconnected to the luminaire. 3.3.2 Unlatch and remove the optical assembly. 3.3.3 Remove the two screws attaching the LED COB Module. 3.3.4 Slowly lower the LED COB Module, and disconnect the DC Connection. Do not attempt to connect and/or disconnect the electrical harness of the LED COB Module to the Driver Module while electrical power is connected to the luminaire, as this can damage the LED COB Module, thereby shortening the life of the LEDs or making the luminaire immediately inoperable or shortly thereafter. N'essayez pas de brancher ou débrancher le faisceau de câbles électriques du module COB DEL au module pilote lorsque le luminaire est sous tension, car cela risque d'endommager le module COB DEL, réduisant ainsi la durée de vie des DEL ou rendant le luminaire inutilisable, directement ou peu de temps après. 3.3.5 Remove the LED COB Module and replace with new Module, shown below. Tighten fastener to between 25 and 35 IN-LBS. Catalog No. BALED5L3K- BALED5L4K- BALED5L5K- LED COB MODULE ACEMENT 3K LED COB MODULE ACEMENT 4K LED COB MODULE ACEMENT 5K 3.3.6 Reinstall the optical assembly. See Section 2.3 3.4 Driver Module or Surge Module Replacement, See Figure 6 3.4.1 Verify that power has been disconnected to the luminaire. 3.4.2 Remove the wiring chamber cover and disconnect the electrical supply wires from the luminaire wires. 3.4.3 Unlatch and remove the optical assembly. 3.4.4 Remove the two screws attaching the LED COB Module, slowly lower the module and place onto hanging bracket, and disconnect the DC Connection. 3.4.5 For Driver Module, remove the two screws attaching the Driver Module and replace with new Module, shown below. Tighten fastener to between 25 and 35 IN-LBS. Catalog No. BALEDAS- DRIVER MODULE ACEMENT AUTO-SENSING INPUT VOLTAGE 120-277VAC NOMINAL 3.4.6 For Surge Module, disconnect Surge Module. 3.4.6.1 Remove the nut attaching the Surge Module and replace with new Module, shown below. Catalog No. CT285- SURGE MODULE ACEMENT 277V MAX. 3.4.7 Reinstall LED COB Module. 3.4.8 Reinstall the luminaire. See Section 2.2 3.4.9 Reinstall the optical assembly. See Section 2.3

Figure 6 GR2257 4. Limited Warranty and Limitation of Liability Limited warranty located at www.acuitybrands.com/customerresources/terms_and _conditions.aspx Acuity Brands Lighting, Inc. 3825 Columbus Rd., Granville, OH 43023 3/20 2014 Acuity Brands Lighting, Inc. All Rights Reserved. Visit our web site at www.holophane.com