Data Centre. Flexible, high efficiency cooling solutions. www.airedale.com CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING



Similar documents
Data Centre. Flexible, high efficiency cooling solutions. CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING

EasiCool. 6-64kW DX AIR. Precision Air Conditioning

Product Guide. BRITISH MANUFACTURER TRAINING ENERGY EFFICIENCY

TurboChill & TurboChill FreeCool

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

State of the Art Energy Efficient Data Centre Air Conditioning

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Direct Fresh Air Free Cooling of Data Centres

Blade Server & Data Room Cooling Specialists

Elements of Energy Efficiency in Data Centre Cooling Architecture

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

In Row Cooling Options for High Density IT Applications

How To Improve Energy Efficiency Through Raising Inlet Temperatures

How To Improve Energy Efficiency In A Data Center

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

RiMatrix S Make easy.

White Paper Rack climate control in data centres

AIRAH Presentation April 30 th 2014

EXAMPLE OF A DATA CENTRE BUILD

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

News in Data Center Cooling

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

SMART SHELTER CONTAINER

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Capgemini UK Infrastructure Outsourcing

Screw Compressors ESM Fixed Speed & VS Variable Speed

University of St Andrews. Energy Efficient Data Centre Cooling

System solution for data centres

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

AHU & HVAC Services BARKELL AIR HANDLING UNITS

APC APPLICATION NOTE #112

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

National Grid Your Partner in Energy Solutions

Data Center Technology: Physical Infrastructure

CRAC Precision climate control units for data centres

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

JAWAHARLAL NEHRU UNIVERSITY

- White Paper - Data Centre Cooling. Best Practice

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

European Code of Conduct for Data Centre. Presentation of the Awards 2014

How to Build a Data Centre Cooling Budget. Ian Cathcart

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Improving Data Center Energy Efficiency Through Environmental Optimization

Data Centre Harbour Exchange Square Campus, London Access to unrivalled connectivity.

EHDC. Cooling system for Data Center and server cabinets.

The Benefits of Supply Air Temperature Control in the Data Centre

Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution

Data Center Components Overview

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

Managing Data Centre Heat Issues

Training courses 2016

Drives and motors. A guide to using variable-speed drives and motors in data centres

Reducing Data Center Energy Consumption

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Analysis of data centre cooling energy efficiency

Daikin Altherma. hybrid heat pump. The natural combination

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Improve competiveness of IDC and enterprise data centers with DCIM

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Choosing Close-Coupled IT Cooling Solutions

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Benefits of. Air Flow Management. Data Center

Data Centre Cooling Air Performance Metrics

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Natural geothermal energy.

An Introduction to Cold Aisle Containment Systems in the Data Centre

Power and Cooling for Ultra-High Density Racks and Blade Servers

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Hybrid heat pumps. saving energy and reducing carbon emissions

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

The Different Types of Air Conditioning Equipment for IT Environments

Daikin Altherma Hybrid Heat Pump

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Daikin Altherma Hybrid Heat Pump

European Code of Conduct for Data Centre. Presentation of the Awards 2016

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

Transcription:

Sector Data Centre Data Centre Flexible, high efficiency cooling solutions IT COOLING PRISION AIR CONDITIONING CHILLERS CONDENSERS & CONDENSING UNITS www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING

01 Meeting the challenge with 24/7, cooling solutions Global demand for data exchange is escalating, placing unprecedented constraints on space and power available to the data centre operator. Tightly packed server racks are generating exponentially more computer power and most of this is converted into rejected heat. More cooling for less space and energy Up to83% more cooling per square metre* From small computer rooms to futureproof solutions across multiple data centres Airedale s fl exible, high effi ciency cooling solutions work smarter not harder to give you more cooling for less power and ensure a stable environment and availability 24/7. Airedale systems are designed to minimise space claim: The InRak in-row cooler for example typically offers up to 83% more cooling kw/m 2 *compared to a conventional CRAC unit A 50% drop in air volume gives an 83% reduction in fan power input SmartCool variable air fl ow Optimised air flow fans save up to 70% energy at part load Variable air fl ow uses minimum power to match demand Constant air volume automatically maintains design air volume Constant air pressure is ensured within the fl oor void or aisle

02 Intuitive cooling for a greener data centre Many servers racks are under-utilised and thermal loads can fl uctuate daily. Airedale cooling systems, led by dynamic controls, signifi cantly reduce cost of ownership and carbon footprint through intuitive, modulated cooling. They work effi ciently at part load and eliminate the risk of wasted power consumption. The cooling systems constantly monitor varying load conditions and adapt to anticipated or unexpected load requirements to maintain setpoint. Reducing PUE Airedale cooling systems have a direct, positive impact on PUE. An indicator of the effi ciency of power use in the data centre, the closer the PUE is to 1, the more of the available power can be used by the IT equipment. Smart control of the room Inverter compressors offer 17 100% modulation for exact capacity match Staged cooling increases part load effi ciency by 5% Variable humidity uses 80% less power during de-humidifi cation Electronic Expansion Valves increase system EER by up to 30% at part load InRak : Excellent part load efficiency N (45.6kW of cooling), N+1 (37.4kW of cooling) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Power Input (kw) 46kW N N+1 Power Input EER 57.50 EER Fan configuration 37kW Enhanced Capital Allowance scheme: Selected Airedale products/models are included on the Energy Technology List, offering the potential for investors to claim 100% fi rst-year capital allowance. For details: www.airedale.com and www.eca.gov.uk. EER 90.34 EER 100 90 80 70 60 50 40 30 20 10 0 We are already seeing a PUE of 1.2 I believe we are the fi rst company in the world to install Airedale s advanced technology, the TurboChill FreeCool chiller. When the data centre is operating in free- cooling mode, the PUE has been measured at 1.2 and we expect that to reduce further as we install more equipment. Bob Finn Programme Manager, EDF Energy One kilowatt of power saved every hour 24/7, represents a saving of 876 * a year, equivalent to over 4 tonnes of CO 2 * 0.10/kWh

03 Bespoke, flexible Best practice cooling Airedale has nearly 40 years experience in designing and manufacturing high effi ciency IT cooling solutions. Through continuous development and applying latest technology led by smart control logic, we offer fl exible, bespoke systems that will optimise performance and help you achieve best practice, now and in the future. Versatile, growing with your data centre Our systems give you the confi dence to move from low to medium to high density cooling as you populate and grow your data centre - from small rooms with DX indoor units linked with condensers outside to larger rooms benefi tting from the better heat transfer of chilled water coupled with a free-cooing chiller. Integration: Over 50% energy saving Designed to be stand-alone, together our units are even more effi cient, sharing intelligence. Indoor units can be integrated with a freecooling chiller which reduces total lifecycle costs by typically saving more than 50% of the energy consumed by a conventional chiller (London, UK). Precision Air Conditioning IT Cooling EasiCool 6-60kW R407C DX AIR INVERTER DX AIR DX AIR DX WATER D U AL SmartCool 15-180kW* InRak 10-60kW C OOL CW DX WATER CW FREE COOL DIGITAL ACE (HO) 2-20kW per rack CW OnRak 3-33kW CW Condensers/Condensing units/dry Coolers CW Air Cooled Condensers & Dry Coolers CR 12-165kW () C/CS 11-105kW (R407C) Dry Coolers 10-100kW R407C 24/7 total confidence Resilience is designed into Airedale units from day one and is managed by advanced controls logic to give you complete confi dence that your data centre is never put at risk and to help you achieve data centre tier classifi cation. Dual Cool Two different cooling mediums in the same case: Intelligent controls select which medium acts as the primary source of cooling or which acts as back-up if the primary source fails or is unable to cope with the heat load. Offered as an option in the SmartCool. N+1 fans The OnRak & InRak fans run at 75% capacity during normal operation. If one fan fails, the other three immediately speed up to 100% to provide the same total amount of cooling and maintain temperature control. Chillers BluCube 10 45kW HEAT PUMP INVERTER DeltaChill 110-960kW D/Chill FreeCool 140-1030kW Pressure differential management The InRak, OnRak and ACE (HO) maintain pressure in the rack within the server design envelope, whilst still ensuring temperature is controlled. DX AIR MICRO FREE COOL Automatic transfer switch In the event of a power failure, DeltaChill FreeCool chillers providing free-cooling to indoor units in a Manchester data centre TurboChill 200-1100kW TurboChill FreeCool 200-950kW R134a DIGITAL FREE COOL FREE COOL LogiCool FreeCool 20 / 40kW MICRO power supply is switched instantly to an alternative power supply and cooling continues, supporting redundancy power supply specifi cations in critical data centre builds. Available on selected Airedale products.

04 Low density cooling Directed to the server inlet 5kW heat load per rack Typically low density areas are cooled by positioning racks to create open hot and cold aisles for increased effi ciency compared with a traditionally confi gured room. Downfl ow versions of the EasiCool or SmartCool precision air conditioning units will deliver cooled air through the fl oor directly to the front of the racks. It is the whole design package We have put in an energy effi cient model. The EasiCool is a robust design for the computer room and is giving excellent performance. It is the whole package; Airedale covered all key design considerations. Not many companies can provide Airedale s level of quality and reliability. Edmund Fosbrook, Senior Estate Manager Victoria & Albert Museum Up to 88% saving in power with modulated cooling and hot gas re-heat compared to traditional electric re-heat SmartCool DX 60-150kW SPACE SAVING Up to 6% cooling kw/m 2 ahead of the market SmartCool DX 15 60kW Ideal for small computer rooms Open aisle structure: Offers fl exibility to scale up and reduces mixing of hot and cold air and wasteful warming of previously cooled air; temperatures are more uniform at server inlet and capital cost decreased SMARTCOOL

05 Medium density cooling Using heat to reduce PUE 6 20kW heat load per rack As heat load density in the room increases, the performance of the server racks is signifi cantly enhanced by aisle containment, preventing any mixing of hot and cold air. Capped cold aisles ensure tight control of cold air to the servers, whilst in hot aisle containment, the higher return temperatures increase the units duty and the freecooling opportunity. SMARTCOOL Contained hot aisle Typically where the return temperature increases from 24 C to 35 C, the same SmartCool unit will increase its cooling duty by 30% from 60 to 80kW. In higher setpoint temperatures: The SmartCool operates more effi ciently; free-cooling threshold is increased and working conditions are more comfortable SPACE SAVING Up to10% more cooling kw/m 2 SmartCool CW 93 162kW * Ideal for large data centres * compared to Airedale s previous generation precision air conditioning 49% less fan power running five CRAC units at 80% air flow rather than four run and one standby Temperature (C) 36.0 32.3 28.5 24.8 21.0 Example hot aisle containment: Three SmartCool units are cooling ten 20kW racks; cold aisle temperature is at 21 C and the hot aisle 36 C FREE COOL FREE-COOLING Up to 95% of the year in free-cooling Airedale free-cooling chillers offer concurrent free-cooling - a mixture of free-cooling and/ or mechanical cooling. Concurrent free-cooling enables free-cooling to be captured whenever the ambient is 1 C or more below the return water temperature. In a 24/7 data centre with a typical room temperature of 24 C, over 95% of the year can be spent with freecooling active (cumulative hours, London, UK). Up to 95% of the year spent in free-cooling 65% 700 500 400 300 200 100 0 Cumulative hours London (UK) PUE 1.19 live data, site specifi c Up to95% Ambient temperature ( C) Concurrent free-cooling maximises total free-cooling -5 0 5 10 15 20 25 30 30% Free-cooling only 65% Concurrent free-cooling 5% Mechanical cooling

InRak cooling via the shortest route 06 Ideal for rooms with or without a fl oor void and offering more cooling/m 2 than a CRAC unit, the 10 60kW InRak in-row cooler is also extremely versatile. It can be positioned within a row of six 10kW server cabinets in a medium density room, for example, or sit between two 30kW racks in a higher density area. The InRak directs cold air horizontally to the front of the server racks, which acts like a curtain, providing even cooling top and bottom and maintaining pressure. Temperature (C) 37.0 32.8 28.5 24.3 20.0 Example hot aisle containment: Each pod includes two InRak units; the CW InRak units control the supply temperate of air into the servers at 22 C ±2 C; hot aisle temperature is 36 C CW Up to 90.34 EER * The InRak makes the aisle containment far more efficient CHILLED WATER Optional n+1 fan configuration, smart control logic and fan technology, give the InRak builtin redundancy and excellent part load efficiencies * Energy Effi ciency Ratio The InRak units are very clever; they communicate with each other to maintain pressure and temperature consistent in the room. Their fans are linked to the ACIS and ramp up and down according to demand. ACIS gives us 24/7 control of the operation and peace of mind. When fully populated, Airedale s cooling solution should guarantee an annualised PUE of 1.3 for the room. Mike Marchant Data Centre Manager EMIS

07 High efficiency HO system 50% less air volumes The high effi ciency HO IT cooling system operates with air volumes 50% less than traditional cooling systems. It comprises an HO ACE (Active Cabinet Exhaust) unit, CRAC unit, free-cooling chiller and control system. The combined system ensures the right air temperature, in the correct quantity and at the correct pressure, is presented to the server inlet. Elevated water temperatures allow up to 95% free-cooling. All noise is contained and the entire data centre is at server inlet temperature, eliminating hot spots and creating a more comfortable working environment, with no CW connections in the IT space. Typically 56% energy savings * and payback ** in less than a year At the hub of the HO system, the HO ACE units sit on top of the server cabinets drawing precisely the right amount of hot discharge air from the servers and rejecting it into the ceiling void without any impingement into the IT environment * compared to a conventional downfl ow CW system ** of the increased capital costs Temperature (C) 45.0 40.3 35.5 30.8 26.0 Example HO system: Two CW HO CRAC units are cooling ten server racks with a total load of 180kW. The HO ACE compact hot aisle is at 43 C and server inlet at 27 C SPACE SAVING HO IT Cooling System 36ºC 19%RH Low pressure ceiling void 300mm - 600mm There is no re-circulation of hot air into the IT space, eliminating the need for hot aisles; the HO ACE sits on top of a rack and there are no CW connections required at the rack HO Free-cooling Chiller HO FREE-COOLING CHILLER HO CRAC Return air section 18ºC 55%RH Compact hot aisle HO ACE Floor void 400-1000mm + HO CRAC + HO ACE + HO ACE HO Control system HO CONTROL SYSTEM

08 High density cooling Where it matters > 20kW per rack OnRak targeting hot spots In high density areas hot spots abound and space is at a premium. The OnRak is a resilient rear door heat exchanger, designed to manage discharge temperatures directly from the server into the aisle space. Ideal for dealing with hot spots, the OnRak takes full advantage of the high temperatures, increasing the effi ciency of the cooling system and raising the free-cooling potential when integrated with a free-cooling chiller. Extremely fl exible, it is easily applied directly to a 42 48U rack or supplied with a mating frame to fi t any manufacturer s rack. 144.68 EER * and 88% saving in power input p.a. OnRak with fan Compared to a traditional PAC unit to the same capacity * Energy Effi ciency Ratio The OnRak allows us to go to higher densities Our HPC (High Performance Computing) facility is growing and without the use of the OnRak rear door coolers it would not be possible to go to such high densities. The OnRak has saved us space in an already densely packed environment. It has also given us the fl exibility to fi t rear door heat exchangers to legacy or new cabinets from any manufacturer. Dr Jon Summers Senior Lecturer The University of Leeds Temperature (C) 48.0 42.5 37.0 31.5 26.0 OnRak units each cooling a 20kW heat load; the OnRak s compact hot aisle temperature is 43 C and the cold aisle is 27 C SPACE SAVING The OnRak adds only 200mm to the depth of the server rack

09 Intelligent controls Seamlessly managing your system The control centre of each of our cooling systems is a sophisticated electronic microprocessor specially developed by Airedale. The intelligent microprocessor uses sensors to send and receive messages to and from active components so they respond and interact. By integrating and sequencing components, the controller manages and optimises the system s performance, availability and power draw, giving the operator complete system control. Fully-programmable via the control panel s user-friendly display, the microprocessor can be linked with all standard BMS protocols and will: Trigger alarm messages Operate time scheduling C Integration protocols Send alarm/service messages via email or SMS using an interface Allow adjustment of temperature setpoints ACIS Building Management Taking data centre management to another level ACIS building management system developed by Airedale, enables you to manage smart cooling and other building services, from any manufacturer, in a single, integrated system across multiple sites and communication protocols. ACIS sits at the front end of a building system, putting you in control of reducing operating costs. With the click of a button on a PC, tablet or phone, intelligent information can be pulled back automatically for remote 24/7 monitoring and maintenance including live PUE, EER and COP calculations and power distribution monitoring. Generator/ UPS/Server Energy Manager Sequencer Building lighting

10 Total support Whenever you need it Sharing our expertise By investing in an Airedale cooling system, you can benefi t from our advice, expertise and support all along the way. From design and selection through to commissioning and beyond, we make sure your cooling system reduces your total cost of ownership and gives you maximum system availability and longevity. 1 Talk an directly with 2 Have control complete of your 3 24/7 maintenance support; and 4 engineer experienced site spares Develop your skills +44 (0)113 239 1000 Find out how we design our systems to reduce your whole life costs. Our highly experienced engineers are adept at tailoring our systems to suit your solution. Customers with critical sites can benefi t from our remote monitoring facility. After-sales services include chiller sequencing, network setup and integration as well as a live demonstration and training centre at our headoffi ce. Knowing you have immediate help on hand day or night, is reassuring particularly if you are responsible for keeping critical systems operational 24/7. Realise the full potential of your system; improve its longevity and effi ciency and be F Gas compliant. Avoid downtime with our fast, effi cient spares service. Learn more about your cooling system by attending an air conditioning and refrigeration course in our purpose-built training school. Train on hightech cooling systems and fully operational rigs in our dedicated workshops. Industryrecognised courses also available. Air conditioning & refrigeration courses + Module 1 - Basic refrigeration & air conditioning + Module 2 - Air conditioning installation, commissioning & maintenance + Module 3 - Design principles Regulatory industry courses + ConstructionSkills F-Gas J11 Category 1, 2, 3 & 4 + ConstructionSkills JO4 & JO5 Pipework & Brazing + ConstructionSkills Essential & Refrigeration Electrics + Air conditioning & refrigeration technology Book online: www.airedale.com/training ChillerGuard and SafeCool Service Plans maximising your system s effi ciency 24/7 An Airedale service plan provides a planned, preventative maintenance package to sustain the optimum effi ciency of your system and enable the user to see real savings in energy costs and reduced carbon emissions. A priority, 24/7 emergency helpline; professional support and call-out service is on hand throughout the year with guaranteed response by a fully qualifi ed Airedale engineer. The service plan also ensures F Gas compliance and incorporates a full parts and labour warranty for the fi rst 12 months. For more information visit www.airedale.com * For customers outside the UK, our international distributors trained by Airedale would be pleased to offer service on Airedale units

Distributed by: ISO 14001 EMS52086 ISO 9001 FM00542 Airedale International Air Conditioning Limited Leeds Road, Rawdon, Leeds LS19 6JY, England Tel: +44 (0) 113 239 1000 Fax: +44 (0) 113 250 7219 E-Mail: enquiries@airedale.com www.airedale.com All specifi cations are subject to change without prior notice ENG-IT-DC12p-11-12